{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608266","name":"Josephine No 3 Mine","status":"Abandoned","status_date":"2018-08-09","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Raleigh","nearest_town":"Josephine","operator_id":"0065824","operator_name":"Pocahontas Coal Company LLC","controller_id":"0085453","controller_name":"Metinvest B V","district":"C04","office":"Beckley District","employees":0,"latitude":37.616389,"longitude":-81.2125},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":4831},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"operator":{"type":"operator","id":"0065824","name":"Pocahontas Coal Company LLC"},"controller":{"type":"controller","id":"0085453","name":"Metinvest B V"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01620","name":"Henry Paul  Kizer et al"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"1988-01-01","validTo":"1997-03-09","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|C01620|1988-01-01|1997-03-09"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19328","name":"Tommy Creek Coal Company"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"1993-02-01","validTo":"1997-03-09","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P19328|1993-02-01|1997-03-09"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01620","name":"Henry Paul  Kizer et al"},"object":{"type":"operator","id":"P19328","name":"Tommy Creek Coal Company"},"validFrom":"1993-02-01","validTo":"1997-03-09","current":false,"derived":true,"evidenceMineId":"4608266","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P19328|1993-02-01|C01620|1988-01-01|55304"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10977","name":"Timothy L  McCoy"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"1994-01-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|C10977|1994-01-18|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22608","name":"Essential Fuels Inc"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"1997-03-10","validTo":"1999-02-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P22608|1997-03-10|1999-02-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10977","name":"Timothy L  McCoy"},"object":{"type":"operator","id":"P22608","name":"Essential Fuels Inc"},"validFrom":"1997-03-10","validTo":"1999-02-01","current":false,"derived":true,"evidenceMineId":"4608266","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P22608|1997-03-10|C10977|1994-01-18|83257"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24068","name":"Rhino Mining Inc"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"1999-02-02","validTo":"2002-12-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P24068|1999-02-02|2002-12-03"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15779","name":"Larry B  McKinney"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"1999-02-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|C15779|1999-02-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15779","name":"Larry B  McKinney"},"object":{"type":"operator","id":"P24068","name":"Rhino Mining Inc"},"validFrom":"1999-02-02","validTo":"2002-12-03","current":false,"derived":true,"evidenceMineId":"4608266","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P24068|1999-02-02|C15779|1999-02-02|96740"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06286","name":"White Mountain Mining Co., LLC"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"1999-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|C06286|1999-11-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06286","name":"White Mountain Mining Co., LLC"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"2001-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|C06286|2001-02-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24265","name":"White Mountain Mining Co., LLC"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"2002-12-04","validTo":"2003-02-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P24265|2002-12-04|2003-02-03"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06286","name":"White Mountain Mining Co., LLC"},"object":{"type":"operator","id":"P24265","name":"White Mountain Mining Co., LLC"},"validFrom":"2002-12-04","validTo":"2003-02-03","current":false,"derived":true,"evidenceMineId":"4608266","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P24265|2002-12-04|C06286|2001-02-01|71395"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24632","name":"Black Hawk Mining"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"2003-02-04","validTo":"2005-11-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P24632|2003-02-04|2005-11-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06286","name":"White Mountain Mining Co., LLC"},"object":{"type":"operator","id":"P24632","name":"Black Hawk Mining"},"validFrom":"2003-02-04","validTo":"2005-11-14","current":false,"derived":true,"evidenceMineId":"4608266","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|P24632|2003-02-04|C06286|1999-11-01|71391"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0065824","name":"Pocahontas Coal Company LLC"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"2005-11-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|0065824|2005-11-15|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"2005-11-15","validTo":"2009-04-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|C00375|2005-11-15|2009-04-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"operator","id":"0065824","name":"Pocahontas Coal Company LLC"},"validFrom":"2005-11-15","validTo":"2009-04-29","current":false,"derived":true,"evidenceMineId":"4608266","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|0065824|2005-11-15|C00375|2005-11-15|46676"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"mine","id":"4608266","name":"Josephine No 3 Mine"},"validFrom":"2009-04-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|0085453|2009-04-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"operator","id":"0065824","name":"Pocahontas Coal Company LLC"},"validFrom":"2009-04-30","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608266","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608266|0065824|2005-11-15|0085453|2009-04-30|13615"}}],"coverage":{"historyRecords":7,"edgeCount":20,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":77,"firstDate":"2003-09-06","lastDate":"2013-11-21","metrics":{"daysLost":2324,"injuries":51,"fatalities":0,"recentRows":0,"restrictedDays":41,"contractorRecords":3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"244633","DOCUMENT_NO":"220133380005","ACCIDENT_DT":"11/21/2013","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"While pillaring the PCC Mains mining in the #4 entry second lift on the left side a large rock fell out and pinned the head. While trying to work the miner pivoting back and forth the breaker knocked on the side of the miner. A retrieval plan was implemented to use a retriever to pull the miner out from under the rock.","sourceDate":"2013-11-21"},{"SOURCE_ROW_NUMBER":"102464","DOCUMENT_NO":"220133220037","ACCIDENT_DT":"11/08/2013","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"While conducting his weekly examination the fire boss identified a roof fall in the #9 entry near spad #6887. The fall was approx. 20'W X 160'L X 4'-5'H the area was supported with 4' fully grouted resin bolts. The area will not be cleaned up and the area has been dangered off and timbers or cribs set.","sourceDate":"2013-11-08"},{"SOURCE_ROW_NUMBER":"145571","DOCUMENT_NO":"220131960035","ACCIDENT_DT":"07/11/2013","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was tramming a Fairchild 35C scoop from outside to the section in the secondary escapeway (roadway), when dust flew in his eye. This is to report medical treatment only no days were missed.","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"132572","DOCUMENT_NO":"220131830008","ACCIDENT_DT":"06/27/2013","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was bolting top when his drill steel got stuck; he reached to pull it out & it slipped through his hands.The drill steel hit the drill pot this caused the drill steel to bounce up & knock the employees safety glasses off.The hot drill bit then hit him in his eye & caused a burn which required medical treatment.This is to report medical treatment only NO days were missed.","sourceDate":"2013-06-27"},{"SOURCE_ROW_NUMBER":"98175","DOCUMENT_NO":"220131330027","ACCIDENT_DT":"04/30/2013","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"49","NARRATIVE":"Employee operated a CM for twenty years and noticed pain in his hands. He was later diagnosed with CTS and had surgery 4/30/13. He was placed off work on 5/1/13 and continues to be off.","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"223086","DOCUMENT_NO":"220131230012","ACCIDENT_DT":"04/19/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Pumper","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"Employee was helping lap belt when the fork fell off the fork loader. The employee picked up the fork and put it back on and felt a sharp pain in his lower back. The employee was treated and released with a referral to a specialist for an MRI. It was later determined the employee had a bulging disc and remains off.","sourceDate":"2013-04-19"},{"SOURCE_ROW_NUMBER":"51000","DOCUMENT_NO":"220123260004","ACCIDENT_DT":"11/09/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"84","NARRATIVE":"The employee was building a stopping when a 4-wheeled rubber tired mantrip suddenly drifted off. The injured twisted his right ankle when he attempted to stop the mantrip. This resulted in a f ractured bone above his right ankle.","sourceDate":"2012-11-09"},{"SOURCE_ROW_NUMBER":"25362","DOCUMENT_NO":"220123140007","ACCIDENT_DT":"10/29/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While walking quickly to turn off the remote switch the employee tripped and fell on the moving belt which caused his left leg to get caught between the belt structure. This caused a fracture of his left foot, fracture of his third toe and a laceration on his fourth toe. This is to report medical treatment only no days were missed.","sourceDate":"2012-10-29"},{"SOURCE_ROW_NUMBER":"145570","DOCUMENT_NO":"220120750033","ACCIDENT_DT":"03/11/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"During the preshift exam the fireboss identified a roof fall on the 2nd Lt. Section 450 outby the face in the #5 entry. The fall measured 20'W X 100'L X10'H.The area was supported with 5'resin bolts and the intersection with 8' cable bolts. The area was dangered off and cribs set. The fall will not be cleaned up and the section will be moved.","sourceDate":"2012-03-11"},{"SOURCE_ROW_NUMBER":"3795","DOCUMENT_NO":"220120330004","ACCIDENT_DT":"01/27/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While operating a Roof Ranger II from the operator side installing the last row of bolts in the number #7 entry a piece of draw rock fell striking the employee on his right hand. This caused a laceration above his right little finger that required sutures. This is to report medical treatment only NO days were missed.","sourceDate":"2012-01-27"},{"SOURCE_ROW_NUMBER":"33880","DOCUMENT_NO":"220113560032","ACCIDENT_DT":"12/10/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was tramming bolt machine from #2-#1 entry from the deck. The T-bar hit the rib he placed his right hand on the canopy to raise himself to see. Just as he did the bolter shifted due to a downhill grade causing the fingers on his right hand to be pinched against the  roof. This resulted in lacerations that required sutures. No days were missed however he is restricted duty.","sourceDate":"2011-12-10"},{"SOURCE_ROW_NUMBER":"132571","DOCUMENT_NO":"220112340020","ACCIDENT_DT":"08/08/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE had scooped up an insert full of bolts to take to the section. While turning to back out of the crosscut he pinched his left hand and little finger between the deck and the coal rib. This caused a laceration that required sutures. This is to report medical treatment only NO days were missed.","sourceDate":"2011-08-08"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2018-08-09","lastDate":"2018-08-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":914,"firstDate":"2000-01-24","lastDate":"2014-03-17","metrics":{"ss":276,"delinquent":881,"recentRows":0,"paidPenalty":497484.99,"proposedPenalty":789610,"currentAssessment":502868},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1853136","VIOLATION_NO":"9016968","ISSUE_DT":"03/17/2014","CFR_STANDARD_CD":"75.1106-3(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-03-17"},{"SOURCE_ROW_NUMBER":"1853013","VIOLATION_NO":"9014915","ISSUE_DT":"12/04/2013","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"1853012","VIOLATION_NO":"9014914","ISSUE_DT":"12/04/2013","CFR_STANDARD_CD":"75.351(d)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"1853011","VIOLATION_NO":"9012228","ISSUE_DT":"10/28/2013","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"1853010","VIOLATION_NO":"9012227","ISSUE_DT":"10/28/2013","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1944.00","CURRENT_ASSESSMENT_AMT":"1000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"1853009","VIOLATION_NO":"9012226","ISSUE_DT":"10/28/2013","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"1856475","VIOLATION_NO":"4201771","ISSUE_DT":"10/16/2013","CFR_STANDARD_CD":"75.360(b)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"1856474","VIOLATION_NO":"4201770","ISSUE_DT":"10/16/2013","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"1856473","VIOLATION_NO":"4201769","ISSUE_DT":"10/16/2013","CFR_STANDARD_CD":"75.380(d)(7)(iv)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"873.00","CURRENT_ASSESSMENT_AMT":"873.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"1856472","VIOLATION_NO":"4201768","ISSUE_DT":"10/16/2013","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"1849376","VIOLATION_NO":"9012050","ISSUE_DT":"10/16/2013","CFR_STANDARD_CD":"75.380(d)(7)(vii)(B)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2282.00","CURRENT_ASSESSMENT_AMT":"1594.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"1849375","VIOLATION_NO":"9012049","ISSUE_DT":"10/16/2013","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-10-16"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":194,"firstDate":"2006-01-20","lastDate":"2015-02-18","metrics":{"appeals":0,"decisions":194,"recentRows":0,"decisionPenalty":313009,"originalPenalty":615596},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"353441","VIOLATION_NO":"9012050","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1594.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-02-18"},{"SOURCE_ROW_NUMBER":"353317","VIOLATION_NO":"4201769","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"873.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-02-18"},{"SOURCE_ROW_NUMBER":"103545","VIOLATION_NO":"9012227","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-02-18"},{"SOURCE_ROW_NUMBER":"103386","VIOLATION_NO":"7233197","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-02-18"},{"SOURCE_ROW_NUMBER":"315674","VIOLATION_NO":"8098338","DOCKET_NO":"WEVA 2012-505","DECISION_DT":"12/08/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"2282.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"315264","VIOLATION_NO":"8128792","DOCKET_NO":"WEVA 2012-505","DECISION_DT":"12/08/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1795.00","DECISION_PENALTY_AMT":"1795.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"315108","VIOLATION_NO":"8128790","DOCKET_NO":"WEVA 2012-505","DECISION_DT":"12/08/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"2106.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"80822","VIOLATION_NO":"8098337","DOCKET_NO":"WEVA 2012-505","DECISION_DT":"12/08/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1800.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"80738","VIOLATION_NO":"8128794","DOCKET_NO":"WEVA 2012-505","DECISION_DT":"12/08/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"330187","VIOLATION_NO":"8135204","DOCKET_NO":"WEVA 2012-1618","DECISION_DT":"11/07/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"32810.00","DECISION_PENALTY_AMT":"32810.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-11-07"},{"SOURCE_ROW_NUMBER":"329925","VIOLATION_NO":"8135205","DOCKET_NO":"WEVA 2012-1618","DECISION_DT":"11/07/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18742.00","DECISION_PENALTY_AMT":"5645.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-11-07"},{"SOURCE_ROW_NUMBER":"342664","VIOLATION_NO":"7170363","DOCKET_NO":"WEVA 2013-783","DECISION_DT":"11/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"1160.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2014-11-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1049,"firstDate":"2000-01-17","lastDate":"2013-12-04","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":121,"validSamples":928,"maxConcentration":24.194,"concentrationTotal":716.78},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1493508","CASS_NUM":"58102174","SMP_TAKEN_DT":"12/4/2013","CONC":".626","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"1173091","CASS_NUM":"58102172","SMP_TAKEN_DT":"12/4/2013","CONC":".089","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"1109194","CASS_NUM":"58102169","SMP_TAKEN_DT":"12/4/2013","CONC":".399","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"958093","CASS_NUM":"58102175","SMP_TAKEN_DT":"12/4/2013","CONC":"1.01","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"226548","CASS_NUM":"58102083","SMP_TAKEN_DT":"12/4/2013","CONC":".467","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"29918","CASS_NUM":"58102085","SMP_TAKEN_DT":"12/4/2013","CONC":"2.429","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"1204998","CASS_NUM":"51243567","SMP_TAKEN_DT":"11/7/2013","CONC":"1.043","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"1245435","CASS_NUM":"51243795","SMP_TAKEN_DT":"11/6/2013","CONC":"1.566","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"353407","CASS_NUM":"51243880","SMP_TAKEN_DT":"11/6/2013","CONC":".613","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"1078505","CASS_NUM":"51243800","SMP_TAKEN_DT":"11/5/2013","CONC":".685","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-05"},{"SOURCE_ROW_NUMBER":"1001514","CASS_NUM":"51243882","SMP_TAKEN_DT":"11/5/2013","CONC":"2.117","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-05"},{"SOURCE_ROW_NUMBER":"1512225","CASS_NUM":"51243572","SMP_TAKEN_DT":"10/9/2013","CONC":"1.054","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-10-09"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":19,"firstDate":"2005-02-03","lastDate":"2014-04-01","metrics":{"linkedIssuances":19},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":194,"firstDate":"2004-06-08","lastDate":"2013-10-28","metrics":{"decisions":194,"ssChanged":79,"recentRows":0,"decisionPenalty":313009,"proposedPenalty":615596},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"433845","CITATION_NO":"9012227","CITATION_ISSUE_DT":"10/28/2013","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1000.00","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"263161","CITATION_NO":"9012050","CITATION_ISSUE_DT":"10/16/2013","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","CFR_STANDARD_CODE":"75.380(d)(7)(vii)(B)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1594.00","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"143471","CITATION_NO":"4201769","CITATION_ISSUE_DT":"10/16/2013","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"873.00","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"376269","CITATION_NO":"7233197","CITATION_ISSUE_DT":"10/15/2013","DOCKET_NO":"WEVA 2014-415","DECISION_DT":"02/18/2015","CFR_STANDARD_CODE":"75.380(d)(7)(vi)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4000.00","sourceDate":"2013-10-15"},{"SOURCE_ROW_NUMBER":"370995","CITATION_NO":"7190975","CITATION_ISSUE_DT":"05/15/2013","DOCKET_NO":"WEVA 2013-1232","DECISION_DT":"05/30/2014","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7578.00","DECISION_PENALTY_AMT":"3750.00","sourceDate":"2013-05-15"},{"SOURCE_ROW_NUMBER":"201640","CITATION_NO":"7190974","CITATION_ISSUE_DT":"05/15/2013","DOCKET_NO":"WEVA 2013-1232","DECISION_DT":"05/30/2014","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"7578.00","DECISION_PENALTY_AMT":"3750.00","sourceDate":"2013-05-15"},{"SOURCE_ROW_NUMBER":"428077","CITATION_NO":"8106472","CITATION_ISSUE_DT":"05/14/2013","DOCKET_NO":"WEVA 2013-1231","DECISION_DT":"05/30/2014","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1700.00","DECISION_PENALTY_AMT":"850.00","sourceDate":"2013-05-14"},{"SOURCE_ROW_NUMBER":"367986","CITATION_NO":"8153147","CITATION_ISSUE_DT":"02/04/2013","DOCKET_NO":"WEVA 2013-783","DECISION_DT":"11/05/2014","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"8893.00","DECISION_PENALTY_AMT":"3800.00","sourceDate":"2013-02-04"},{"SOURCE_ROW_NUMBER":"85086","CITATION_NO":"8153148","CITATION_ISSUE_DT":"02/04/2013","DOCKET_NO":"WEVA 2013-783","DECISION_DT":"11/05/2014","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"2282.00","sourceDate":"2013-02-04"},{"SOURCE_ROW_NUMBER":"371125","CITATION_NO":"8153132","CITATION_ISSUE_DT":"11/14/2012","DOCKET_NO":"WEVA 2013-508","DECISION_DT":"09/02/2014","CFR_STANDARD_CODE":"75.904","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"345.00","sourceDate":"2012-11-14"},{"SOURCE_ROW_NUMBER":"317693","CITATION_NO":"8153131","CITATION_ISSUE_DT":"11/13/2012","DOCKET_NO":"WEVA 2013-508","DECISION_DT":"09/02/2014","CFR_STANDARD_CODE":"75.1714-6","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"374.00","sourceDate":"2012-11-13"},{"SOURCE_ROW_NUMBER":"147727","CITATION_NO":"8153130","CITATION_ISSUE_DT":"11/13/2012","DOCKET_NO":"WEVA 2013-508","DECISION_DT":"09/02/2014","CFR_STANDARD_CODE":"75.1100-2(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"378.00","sourceDate":"2012-11-13"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":867,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":145,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"1993-02-01","lastDate":"2005-11-15","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":104,"firstDate":"2000-01-20","lastDate":"2018-08-05","metrics":{"inspectors":206,"recentRows":0,"onSiteHours":5022.75,"inspectionHours":8150.5,"inspectionSamples":870},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1131842","EVENT_NO":"7004487","INSPECTION_BEGIN_DT":"08/05/2018","INSPECTION_END_DT":"08/05/2018","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.75","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2018-08-05"},{"SOURCE_ROW_NUMBER":"1015016","EVENT_NO":"6307726","INSPECTION_BEGIN_DT":"08/01/2016","INSPECTION_END_DT":"08/01/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2016-08-01"},{"SOURCE_ROW_NUMBER":"177489","EVENT_NO":"6304534","INSPECTION_BEGIN_DT":"04/06/2015","INSPECTION_END_DT":"04/07/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.25","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2015-04-06"},{"SOURCE_ROW_NUMBER":"702847","EVENT_NO":"6301671","INSPECTION_BEGIN_DT":"01/12/2015","INSPECTION_END_DT":"01/13/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2015-01-12"},{"SOURCE_ROW_NUMBER":"174519","EVENT_NO":"6301443","INSPECTION_BEGIN_DT":"10/01/2014","INSPECTION_END_DT":"10/02/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.75","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2014-10-01"},{"SOURCE_ROW_NUMBER":"151292","EVENT_NO":"6300939","INSPECTION_BEGIN_DT":"09/16/2014","INSPECTION_END_DT":"09/16/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"149338","EVENT_NO":"6297486","INSPECTION_BEGIN_DT":"04/02/2014","INSPECTION_END_DT":"05/01/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"21","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2014-04-02"},{"SOURCE_ROW_NUMBER":"298981","EVENT_NO":"6300924","INSPECTION_BEGIN_DT":"03/17/2014","INSPECTION_END_DT":"03/20/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22.5","SUM_TOTAL_ON_SITE_HOURS":"13.25","sourceDate":"2014-03-17"},{"SOURCE_ROW_NUMBER":"531207","EVENT_NO":"6304159","INSPECTION_BEGIN_DT":"11/21/2013","INSPECTION_END_DT":"12/05/2013","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2013-11-21"},{"SOURCE_ROW_NUMBER":"1130976","EVENT_NO":"6300920","INSPECTION_BEGIN_DT":"10/28/2013","INSPECTION_END_DT":"12/30/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"50.5","SUM_TOTAL_ON_SITE_HOURS":"30","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"923348","EVENT_NO":"6301372","INSPECTION_BEGIN_DT":"10/21/2013","INSPECTION_END_DT":"11/04/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"14.75","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2013-10-21"},{"SOURCE_ROW_NUMBER":"271979","EVENT_NO":"6300033","INSPECTION_BEGIN_DT":"10/16/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.25","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2013-10-16"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":168,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2018-Q3":{"hours":0,"employees":0,"production":0},"2018-Q2":{"hours":0,"employees":0,"production":0},"2018-Q1":{"hours":0,"employees":0,"production":0},"2017-Q4":{"hours":0,"employees":0,"production":0},"2017-Q3":{"hours":0,"employees":0,"production":0},"2017-Q2":{"hours":0,"employees":0,"production":0},"2017-Q1":{"hours":0,"employees":0,"production":0},"2016-Q4":{"hours":0,"employees":0,"production":0},"2016-Q3":{"hours":0,"employees":0,"production":0},"2016-Q2":{"hours":0,"employees":0,"production":0},"2015-Q3":{"hours":0,"employees":0,"production":0},"2015-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":34,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":165083,"employees":74,"production":323099},"2006":{"hours":156689,"employees":68,"production":353729},"2007":{"hours":209323,"employees":94,"production":330447},"2008":{"hours":144483,"employees":50,"production":293120},"2009":{"hours":139711,"employees":60,"production":279834},"2010":{"hours":183695,"employees":64,"production":219605},"2011":{"hours":150854,"employees":50,"production":186788},"2012":{"hours":188113,"employees":70,"production":187959},"2013":{"hours":176871,"employees":62,"production":190498},"2014":{"hours":12356,"employees":24,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":39,"firstDate":"2008-03-21","lastDate":"2013-09-11","metrics":{"recentRows":0,"doseOver100":10,"actDoseTotal":3285,"pelDoseTotal":2703},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"235940","EVENT_NO":"6297531","SURVEY_DATE":"09/11/2013","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"28","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2013-09-11"},{"SOURCE_ROW_NUMBER":"235939","EVENT_NO":"6297531","SURVEY_DATE":"09/11/2013","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"24","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2013-09-11"},{"SOURCE_ROW_NUMBER":"235938","EVENT_NO":"6297531","SURVEY_DATE":"09/11/2013","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"18","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2013-09-11"},{"SOURCE_ROW_NUMBER":"235937","EVENT_NO":"6297531","SURVEY_DATE":"09/11/2013","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"18","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2013-09-11"},{"SOURCE_ROW_NUMBER":"235936","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"40","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"235935","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"70","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"235934","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"33","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"235933","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"73","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"235932","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"81","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"235931","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"47","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"235930","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"115","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"235929","EVENT_NO":"6294662","SURVEY_DATE":"02/07/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"78","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2012-02-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":86,"firstDate":"2004-03-23","lastDate":"2013-12-04","metrics":{"recentRows":0,"voidSamples":8,"maxQuartzPct":29.2,"validSamples":78,"quartzPctTotal":508.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"132725","CASSETTE_NO":"58102175","SAMPLE_DT":"12/04/2013","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"163256","CASSETTE_NO":"58011703","SAMPLE_DT":"05/20/2013","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-05-20"},{"SOURCE_ROW_NUMBER":"139431","CASSETTE_NO":"58008157","SAMPLE_DT":"02/26/2013","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-02-26"},{"SOURCE_ROW_NUMBER":"34792","CASSETTE_NO":"58008191","SAMPLE_DT":"02/26/2013","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-02-26"},{"SOURCE_ROW_NUMBER":"29192","CASSETTE_NO":"57971087","SAMPLE_DT":"10/24/2012","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-10-24"},{"SOURCE_ROW_NUMBER":"92395","CASSETTE_NO":"51181743","SAMPLE_DT":"08/27/2012","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-08-27"},{"SOURCE_ROW_NUMBER":"127280","CASSETTE_NO":"57965270","SAMPLE_DT":"08/07/2012","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-08-07"},{"SOURCE_ROW_NUMBER":"123567","CASSETTE_NO":"57965519","SAMPLE_DT":"06/19/2012","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-19"},{"SOURCE_ROW_NUMBER":"81039","CASSETTE_NO":"57968306","SAMPLE_DT":"04/23/2012","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-23"},{"SOURCE_ROW_NUMBER":"31653","CASSETTE_NO":"57968302","SAMPLE_DT":"04/23/2012","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-23"},{"SOURCE_ROW_NUMBER":"148892","CASSETTE_NO":"51178356","SAMPLE_DT":"04/05/2012","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-05"},{"SOURCE_ROW_NUMBER":"53017","CASSETTE_NO":"51178129","SAMPLE_DT":"04/04/2012","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2012-04-04"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":932,"firstDate":"2000-01-24","lastDate":"2014-03-17","metrics":{"ss":277,"amountDue":502868,"contested":84,"amountPaid":497484.99,"recentRows":0,"section104d":13,"unterminated":6,"proposedPenalty":789610},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2706107","VIOLATION_NO":"9016968","VIOLATION_ISSUE_DT":"03/17/2014","SIG_SUB":"N","PART_SECTION":"75.1106-3(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/17/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-03-17"},{"SOURCE_ROW_NUMBER":"2706807","VIOLATION_NO":"9014915","VIOLATION_ISSUE_DT":"12/04/2013","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2013","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"2706806","VIOLATION_NO":"9014914","VIOLATION_ISSUE_DT":"12/04/2013","SIG_SUB":"N","PART_SECTION":"75.351(d)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2013","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"2706808","VIOLATION_NO":"9012656","VIOLATION_ISSUE_DT":"11/21/2013","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"11/21/2013","CONTESTED_IND":"N","sourceDate":"2013-11-21"},{"SOURCE_ROW_NUMBER":"2706805","VIOLATION_NO":"9012228","VIOLATION_ISSUE_DT":"10/28/2013","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/28/2013","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"2706804","VIOLATION_NO":"9012227","VIOLATION_ISSUE_DT":"10/28/2013","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/21/2013","PROPOSED_PENALTY":"1944","AMOUNT_DUE":"1000","AMOUNT_PAID":"1000","CONTESTED_IND":"N","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"2706803","VIOLATION_NO":"9012226","VIOLATION_ISSUE_DT":"10/28/2013","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/21/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-10-28"},{"SOURCE_ROW_NUMBER":"2706800","VIOLATION_NO":"9012050","VIOLATION_ISSUE_DT":"10/16/2013","SIG_SUB":"Y","PART_SECTION":"75.380(d)(7)(vii)(B)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/21/2013","PROPOSED_PENALTY":"2282","AMOUNT_DUE":"1594","AMOUNT_PAID":"1594","CONTESTED_IND":"N","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"2706799","VIOLATION_NO":"9012049","VIOLATION_ISSUE_DT":"10/16/2013","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/16/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"2706797","VIOLATION_NO":"4201771","VIOLATION_ISSUE_DT":"10/16/2013","SIG_SUB":"N","PART_SECTION":"75.360(b)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/16/2013","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"2706796","VIOLATION_NO":"4201770","VIOLATION_ISSUE_DT":"10/16/2013","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/16/2013","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2013-10-16"},{"SOURCE_ROW_NUMBER":"2706795","VIOLATION_NO":"4201769","VIOLATION_ISSUE_DT":"10/16/2013","SIG_SUB":"Y","PART_SECTION":"75.380(d)(7)(iv)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/16/2013","PROPOSED_PENALTY":"873","AMOUNT_DUE":"873","AMOUNT_PAID":"873","CONTESTED_IND":"N","sourceDate":"2013-10-16"}]}],"safety":{"href":"/api/v1/mines/4608266/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608266/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.351","heading":"Atmospheric monitoring systems.","id":"75.351","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.351","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) AMS operation. Whenever personnel are underground and an AMS is used to fulfill the requirements of §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), the AMS must be operating and a designated AMS operator must be on duty at a location on the surface of the mine where audible and visual signals from the AMS must be seen or heard and the AMS operator can promptly respond to these signals.\n\n(b) Designated surface location and AMS operator. When an AMS is used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), the following requirements apply:\n\n(1) The mine operator must designate a surface location at the mine where signals from the AMS will be received and two-way voice communication is maintained with each working section, with areas where mechanized mining equipment is being installed or removed, and with other areas designated in the approved emergency evacuation and firefighting program of instruction (§ 75.1502).\n\n(2) The mine operator must designate an AMS operator to monitor and promptly respond to all AMS signals. The AMS operator must have as a primary duty the responsibility to monitor the malfunction, alert and alarm signals of the AMS, and to notify appropriate personnel of these signals. In the event of an emergency, the sole responsibility of the AMS operator shall be to respond to the emergency.\n\n(3) A map or schematic must be provided at the designated surface location that shows the locations and type of AMS sensor at each location, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(4) The names of the designated AMS operators and other appropriate personnel, including the designated person responsible for initiating an emergency mine evacuation under § 75.1501, and the method to contact these persons, must be provided at the designated surface location.\n\n(c) Minimum operating requirements. AMSs used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f) must:\n\n(1) Automatically provide visual and audible signals at the designated surface location for any interruption of circuit continuity and any electrical malfunction of the system. These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(2) Automatically provide visual and audible signals at the designated surface location when the carbon monoxide concentration or methane concentration at any sensor reaches the alert level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(3) Automatically provide visual and audible signals at the designated surface location distinguishable from alert signals when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by the AMS operator.\n\n(4) Automatically provide visual and audible signals at all affected working sections and at all affected areas where mechanized mining equipment is being installed or removed when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be of sufficient magnitude to be seen or heard by miners working at these locations. Methane signals must be distinguishable from other signals.\n\n(5) Automatically provide visual and audible signals at other locations as specified in Mine Emergency Evacuation and Firefighting Program of Instruction (§ 75.1502) when the carbon monoxide, smoke, or methane concentration at any sensor reaches the alarm level as specified in § 75.351(i). These signals must be seen or heard by miners working at these locations. Methane alarms must be distinguishable from other signals.\n\n(6) Identify at the designated surface location the operational status of all sensors.\n\n(7) Automatically provide visual and audible alarm signals at the designated surface location, at all affected working sections, and at all affected areas where mechanized mining equipment is being installed or removed when the carbon monoxide level at any two consecutive sensors alert at the same time. These signals must be seen or heard by the AMS operator and miners working at these locations.\n\n(d) Location and installation of AMS sensors. (1) All AMS sensors, as specified in §§ 75.351(e) through 75.351(h), must be located such that measurements are representative of the mine atmosphere in these locations.\n\n(2) Carbon monoxide or smoke sensors must be installed near the center in the upper third of the entry, in a location that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(3) Methane sensors must be installed near the center of the entry, at least 12 inches from the roof, ribs, and floor, in a location that would not expose personnel working on the system to unsafe conditions.\n\n(e) Location of sensors-belt air course. (1) In addition to the requirements of paragraph (d) of this section, any AMS used to monitor belt air courses under § 75.350(b) must have approved sensors to monitor for carbon monoxide at the following locations:\n\n(i) At or near the working section belt tailpiece in the air stream ventilating the belt entry. In longwall mining systems the sensor must be located upwind in the belt entry at a distance no greater than 150 feet from the mixing point where intake air is mixed with the belt air at or near the tailpiece;\n\n(ii) No more than 50 feet upwind from the point where the belt air course is combined with another air course or splits into multiple air courses;\n\n(iii) At intervals not to exceed 1,000 feet along each belt entry. However, in areas along each belt entry where air velocities are between 50 and 100 feet per minute, spacing of sensors must not exceed 500 feet. In areas along each belt entry where air velocities are less than 50 feet per minute, the sensor spacing must not exceed 350 feet;\n\n(iv) Not more than 100 feet downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up; and\n\n(v) At other locations in any entry that is part of the belt air course as required and specified in the mine ventilation plan.\n\n(2) Smoke sensors must be installed to monitor the belt entry under § 75.350(b) at the following locations:\n\n(i) At or near the working section belt tailpiece in the air stream ventilating the belt entry. In longwall mining systems the sensor must be located upwind in the belt entry at a distance no greater than 150 feet from the mixing point where intake air is mixed with the belt air at or near the tailpiece;\n\n(ii) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece, transfer point, and each belt take-up; and\n\n(iii) At intervals not to exceed 3,000 feet along each belt entry.\n\n(iv) This provision shall be effective one year after the Secretary has determined that a smoke sensor is available to reliably detect fire in underground coal mines.\n\n(f) Locations of sensors—the primary escapeway. When used to monitor the primary escapeway under § 75.350(b)(4), carbon monoxide or smoke sensors must be located in the primary escapeway within 500 feet of the working section and areas where mechanized mining equipment is being installed or removed. In addition, another sensor must be located within 500 feet inby the beginning of the panel. The point-feed sensor required by § 75.350(d)(1) may be used as the sensor at the beginning of the panel if it is located within 500 feet inby the beginning of the panel.\n\n(g) Location of sensors—return air splits. (1) If used to monitor return air splits under § 75.362(f), a methane sensor must be installed in the return air split between the last working place, longwall or shortwall face ventilated by that air split, and the junction of the return air split with another air split, seal, or worked out area.\n\n(2) If used to monitor a return air split under § 75.323(d)(1)(ii), the methane sensors must be installed at the following locations:\n\n(i) In the return air course opposite the section loading point, or, if exhausting auxiliary fan(s) are used, in the return air course no closer than 300 feet downwind from the fan exhaust and at a point opposite or immediately outby the section loading point; and\n\n(ii) Immediately upwind from the location where the return air split meets another air split or immediately upwind of the location where an air split is used to ventilate seals or worked-out areas.\n\n(h) Location of sensors—electrical installations. When monitoring the intake air ventilating underground transformer stations, battery charging stations, substations, rectifiers, or water pumps under § 75.340(a)(1)(ii) or § 75.340(a)(2)(ii), at least one sensor must be installed to monitor the mine atmosphere for carbon monoxide or smoke, located downwind and not greater than 50 feet from the electrical installation being monitored.\n\n(i) Establishing alert and alarm levels. An AMS installed in accordance with the following paragraphs must initiate alert and alarm signals at the specified levels, as indicated:\n\n(1) For § 75.323(d)(1)(ii) alarm at 1.5% methane.\n\n(2) For §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), and 75.350(d), alert at 5 ppm carbon monoxide above the ambient level and alarm at 10 ppm carbon monoxide above the ambient level when carbon monoxide sensors are used; and alarm at a smoke optical density of 0.022 per meter when smoke sensors are used. Reduced alert and alarm settings approved by the district manager may be required for carbon monoxide sensors identified in the mine ventilation plan, § 75.371(nn).\n\n(3) For § 75.362(f), alert at 1.0% methane and alarm at 1.5% methane.\n\n(j) Establishing carbon monoxide ambient levels. Carbon monoxide ambient levels and the means to determine these levels must be approved in the mine ventilation plan (§ 75.371(hh)) for monitors installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), and 75.350(d).\n\n(k) Installation and maintenance. An AMS installed in accordance with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f) must be installed and maintained by personnel trained in the installation and maintenance of the system. The system must be maintained in proper operating condition.\n\n(l) Sensors. Sensors used to monitor for carbon monoxide, methane, and smoke must be either of a type listed and installed in accordance with the recommendations of a nationally recognized testing laboratory approved by the Secretary; or these sensors must be of a type, and installed in a manner, approved by the Secretary.\n\n(m) Time delays. When a demonstrated need exists, time delays may be incorporated into the AMS. These time delays must only be used to account for non-fire related carbon monoxide alert and alarm sensor signals. These time delays are limited to no more than three minutes. The use and length of any time delays, or other techniques or methods which eliminate or reduce the need for time delays, must be specified and approved in the mine ventilation plan.\n\n(n) Examination, testing, and calibration. (1) At least once each shift when belts are operated as part of a production shift, sensors used to detect carbon monoxide or smoke in accordance with §§ 75.350(b), and 75.350(d), and alarms installed in accordance with § 75.350(b) must be visually examined.\n\n(2) At least once every seven days, alarms for AMS installed in accordance with §§ 75.350(b), and 75.350(d) must be functionally tested for proper operation.\n\n(3) At intervals not to exceed 31 days—\n\n(i) Each carbon monoxide sensor installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), or 75.350(d) must be calibrated in accordance with the manufacturer's calibration specifications. Calibration must be done with a known concentration of carbon monoxide in air sufficient to activate the alarm;\n\n(ii) Each smoke sensor installed in accordance with §§ 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), or 75.350(d) must be functionally tested in accordance with the manufacturer's calibration specifications;\n\n(iii) Each methane sensor installed in accordance with §§ 75.323(d)(1)(ii) or 75.362(f) must be calibrated in accordance with the manufacturer's calibration specifications. Calibration must be done with a known concentration of methane in air sufficient to activate an alarm.\n\n(iv) If the alert or alarm signals will be activated during calibration of sensors, the AMS operator must be notified prior to and upon completion of calibration. The AMS operator must notify miners on affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction (§ 75.1502) when calibration will activate alarms and when calibration is completed.\n\n(4) Gases used for the testing and calibration of AMS sensors must be traceable to the National Institute of Standards and Technology reference standard for the specific gas. When these reference standards are not available for a specific gas, calibration gases must be traceable to an analytical standard which is prepared using a method traceable to the National Institute of Standards and Technology. Calibration gases must be within ±2.0 percent of the indicated gas concentration.\n\n(o) Recordkeeping. (1) When an AMS is used to comply with §§ 75.323(d)(1)(ii), 75.340(a)(1)(ii), 75.340(a)(2)(ii), 75.350(b), 75.350(d), or 75.362(f), individuals designated by the operator must make the following records by the end of the shift in which the following event(s) occur:\n\n(i) If an alert or alarm signal occurs, a record of the date, time, location and type of sensor, and the cause for the activation.\n\n(ii) If an AMS malfunctions, a record of the date, the extent and cause of the malfunction, and the corrective action taken to return the system to proper operation.\n\n(iii) A record of the seven-day tests of alert and alarm signals; calibrations; and maintenance of the AMS must be made by the person(s) performing these actions.\n\n(2) The person entering the record must include their name, date, and signature in the record.\n\n(3) The records required by this section must be kept either in a secure book that is not susceptible to alteration, or electronically in a computer system that is secure and not susceptible to alteration. These records must be maintained separately from other records and identifiable by a title, such as the ‘AMS log.’\n\n(p) Retention period. Records must be retained for at least one year at a surface location at the mine and made available for inspection by miners and authorized representatives of the Secretary.\n\n(q) Training. (1) All AMS operators must be trained annually in the proper operation of the AMS. This training must include the following subjects:\n\n(i) Familiarity with underground mining systems;\n\n(ii) Basic atmospheric monitoring system requirements;\n\n(iii) The mine emergency evacuation and firefighting program of instruction;\n\n(iv) The mine ventilation system including planned air directions;\n\n(v) Appropriate response to alert, alarm and malfunction signals;\n\n(vi) Use of mine communication systems including emergency notification procedures; and\n\n(vii) AMS recordkeeping requirements.\n\n(2) At least once every six months, all AMS operators must travel to all working sections.\n\n(3) A record of the content of training, the person conducting the training, and the date the training was conducted, must be maintained at the mine for at least one year by the mine operator.\n\n(r) Communications. When an AMS is used to comply with § 75.350(b), a two-way voice communication system required by § 75.1600 must be installed in an entry that is separate from the entry in which the AMS is installed no later than August 2, 2004. The two-way voice communication system may be installed in the entry where the intake sensors required by §§ 75.350(b)(4) or 75.350(d)(1) are installed.\n\n[69 FR 17527, Apr. 2, 2004, as amended at 73 FR 80612, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608266","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}