{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4608137","name":"#1 Mine","status":"Abandoned","status_date":"2024-03-19","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Mcdowell","nearest_town":"Jolo","operator_id":"0051227","operator_name":"Coal America, Inc.","controller_id":"C11888","controller_name":"Kenneth D  Bowles","district":"C04","office":"Beckley District","employees":0,"latitude":37.3325,"longitude":-81.859444},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":640},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4608137","name":"#1 Mine"},"operator":{"type":"operator","id":"0051227","name":"Coal America, Inc."},"controller":{"type":"controller","id":"C11888","name":"Kenneth D  Bowles"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C08763","name":"Everett  Delaney et al"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1981-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|C08763|1981-04-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21867","name":"Warren Coal Company Inc"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1991-11-01","validTo":"1993-05-02","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P21867|1991-11-01|1993-05-02"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C08919","name":"James Wayne  Estep"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1991-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|C08919|1991-11-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08919","name":"James Wayne  Estep"},"object":{"type":"operator","id":"P21867","name":"Warren Coal Company Inc"},"validFrom":"1991-11-01","validTo":"1993-05-02","current":false,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P21867|1991-11-01|C08919|1991-11-01|78442"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05381","name":"Raymond  Cline"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1992-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|C05381|1992-12-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P11755","name":"Eastern Energy Corp"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1993-05-03","validTo":"1994-07-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P11755|1993-05-03|1994-07-10"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08763","name":"Everett  Delaney et al"},"object":{"type":"operator","id":"P11755","name":"Eastern Energy Corp"},"validFrom":"1993-05-03","validTo":"1994-07-10","current":false,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P11755|1993-05-03|C08763|1981-04-01|78125"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08763","name":"David  Clevinger et al"},"object":{"type":"operator","id":"P11755","name":"Eastern Energy Corp"},"validFrom":"1993-05-03","validTo":"1994-07-10","current":false,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P11755|1993-05-03|C08763|1981-04-01|78126"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22247","name":"Smurfco Inc"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1994-07-11","validTo":"1996-08-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P22247|1994-07-11|1996-08-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05381","name":"Raymond  Cline"},"object":{"type":"operator","id":"P22247","name":"Smurfco Inc"},"validFrom":"1994-07-11","validTo":"1996-08-29","current":false,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P22247|1994-07-11|C05381|1992-12-01|68655"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23546","name":"Candlestick Coal Company Inc"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1996-08-30","validTo":"2000-02-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P23546|1996-08-30|2000-02-29"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15476","name":"Quinten  Shortridge"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"1996-08-30","validTo":"2000-02-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|C15476|1996-08-30|2000-02-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15476","name":"Quinten  Shortridge"},"object":{"type":"operator","id":"P23546","name":"Candlestick Coal Company Inc"},"validFrom":"1996-08-30","validTo":"2000-02-29","current":false,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P23546|1996-08-30|C15476|1996-08-30|95728"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24362","name":"Eastern Energy Corp."},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"2000-03-01","validTo":"2006-11-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P24362|2000-03-01|2006-11-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C08858","name":"James E  Trent"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"2000-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|C08858|2000-03-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08858","name":"James E  Trent"},"object":{"type":"operator","id":"P24362","name":"Eastern Energy Corp."},"validFrom":"2000-03-01","validTo":"2006-11-16","current":false,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|P24362|2000-03-01|C08858|2000-03-01|78297"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C08858","name":"James E  Trent"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"2003-03-14","validTo":"2006-03-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|C08858|2003-03-14|2006-03-26"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11888","name":"Kenneth D  Bowles"},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"2006-03-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|C11888|2006-03-27|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051227","name":"Coal America, Inc."},"object":{"type":"mine","id":"4608137","name":"#1 Mine"},"validFrom":"2006-11-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|0051227|2006-11-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08858","name":"James E  Trent"},"object":{"type":"operator","id":"0051227","name":"Coal America, Inc."},"validFrom":"2006-11-17","validTo":"2006-03-26","current":false,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|0051227|2006-11-17|C08858|2003-03-14|78308"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11888","name":"Kenneth D  Bowles"},"object":{"type":"operator","id":"0051227","name":"Coal America, Inc."},"validFrom":"2006-11-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4608137","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4608137|0051227|2006-11-17|C11888|2006-03-27|85622"}}],"coverage":{"historyRecords":8,"edgeCount":21,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2001-09-24","lastDate":"2002-02-13","metrics":{"daysLost":157,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"141352","DOCUMENT_NO":"220020560057","ACCIDENT_DT":"02/13/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"INUNDATION","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THE 001 WORKING SECTION CUT INTO OLD WORKS WHILE MINING IN THE #7 HEADING APPROX. 140' INBY SPAD NO 3264 CAUSING WATER TO ENTER THE WORKING SECTION. THE MEN WERE REMOVED FROM THE MINE IMMEDIAT ELY. NO INJURIES REPORTED. THE SECTION POWER CENTER WAS THE ONLY EQUIPMENT AFFECTED BY THE WATER. OLD WORKING WERE NOT PROPERTY LOCATED ON MINE MAP.","sourceDate":"2002-02-13"},{"SOURCE_ROW_NUMBER":"76894","DOCUMENT_NO":"220013540019","ACCIDENT_DT":"12/03/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"143","NARRATIVE":"PULLED SHOULDER OUT BY CARRYING PLASTER BUCKET, HE WENT TO HIS DR WHO REFERRED HIM TO A SPECIALIST. HE HAS NOT RETURNED TO WORK.","sourceDate":"2001-12-03"},{"SOURCE_ROW_NUMBER":"205888","DOCUMENT_NO":"220013540018","ACCIDENT_DT":"10/11/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"GETTING ROOF BOLT OFF OF RIPPER ON MINER. TWISTED AROUND TO WALK OFF AND BACK STARTED HURTING. EMPLOYEE WENT TO CLINCH VALLEY MEDICAL CENTER. HE RETURNED TO WORK ON 10-31-01. FOREMAN'S REPORT WAS LOST OR SENT TO WRONG OFFICE.","sourceDate":"2001-10-11"},{"SOURCE_ROW_NUMBER":"55277","DOCUMENT_NO":"220012770018","ACCIDENT_DT":"09/24/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"UNINTENTIONAL ROOF FALL APPROX. 3-4' HIGH X 40' LONG X 18-20' IN WIDTH WAS DISCOVERED AT APPROX. 2:30 AM ON 9-24-01 WHILE INSPECTING MAIN INTAKE ESCAPEWAY. SPAD 2064-NO. 7 MAIN IN TAKE ESCAPEW AY.","sourceDate":"2001-09-24"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-03-19","lastDate":"2024-03-19","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":154,"firstDate":"2000-03-23","lastDate":"2002-03-11","metrics":{"ss":56,"delinquent":154,"recentRows":0,"paidPenalty":9508.69,"proposedPenalty":13296,"currentAssessment":13296},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"767571","VIOLATION_NO":"7193821","ISSUE_DT":"03/11/2002","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"173.00","CURRENT_ASSESSMENT_AMT":"173.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-11"},{"SOURCE_ROW_NUMBER":"767570","VIOLATION_NO":"7193820","ISSUE_DT":"03/11/2002","CFR_STANDARD_CD":"75.807","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-11"},{"SOURCE_ROW_NUMBER":"767569","VIOLATION_NO":"7193819","ISSUE_DT":"03/06/2002","CFR_STANDARD_CD":"77.207","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"767568","VIOLATION_NO":"7193818","ISSUE_DT":"03/06/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"767567","VIOLATION_NO":"7193817","ISSUE_DT":"03/06/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"767566","VIOLATION_NO":"7193816","ISSUE_DT":"03/06/2002","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"767565","VIOLATION_NO":"7193815","ISSUE_DT":"03/06/2002","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"122.00","CURRENT_ASSESSMENT_AMT":"122.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"767564","VIOLATION_NO":"7193814","ISSUE_DT":"03/05/2002","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"767563","VIOLATION_NO":"7193812","ISSUE_DT":"03/05/2002","CFR_STANDARD_CD":"75.1103","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"773324","VIOLATION_NO":"7211040","ISSUE_DT":"02/15/2002","CFR_STANDARD_CD":"75.1200","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"259.00","CURRENT_ASSESSMENT_AMT":"259.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-02-15"},{"SOURCE_ROW_NUMBER":"773323","VIOLATION_NO":"7211039","ISSUE_DT":"02/15/2002","CFR_STANDARD_CD":"75.388(a)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1270.00","CURRENT_ASSESSMENT_AMT":"1270.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-02-15"},{"SOURCE_ROW_NUMBER":"773322","VIOLATION_NO":"7211038","ISSUE_DT":"02/14/2002","CFR_STANDARD_CD":"50.10","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-02-14"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":176,"firstDate":"2000-05-16","lastDate":"2002-03-29","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":28,"validSamples":148,"maxConcentration":5.639,"concentrationTotal":192.176},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1494603","CASS_NUM":"50650953","SMP_TAKEN_DT":"3/29/2002","CONC":"2.399","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-29"},{"SOURCE_ROW_NUMBER":"1497280","CASS_NUM":"57397664","SMP_TAKEN_DT":"3/15/2002","CONC":".231","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"1008788","CASS_NUM":"57397597","SMP_TAKEN_DT":"3/15/2002","CONC":".181","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"904886","CASS_NUM":"57397560","SMP_TAKEN_DT":"3/15/2002","CONC":".94","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"497792","CASS_NUM":"57397639","SMP_TAKEN_DT":"3/15/2002","CONC":"1.548","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"457829","CASS_NUM":"57397653","SMP_TAKEN_DT":"3/15/2002","CONC":".334","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"299983","CASS_NUM":"57397583","SMP_TAKEN_DT":"3/15/2002","CONC":".316","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"367413","CASS_NUM":"50633602","SMP_TAKEN_DT":"2/6/2002","CONC":"1.085","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-06"},{"SOURCE_ROW_NUMBER":"266583","CASS_NUM":"50633525","SMP_TAKEN_DT":"2/5/2002","CONC":".728","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-05"},{"SOURCE_ROW_NUMBER":"1262396","CASS_NUM":"50620316","SMP_TAKEN_DT":"2/4/2002","CONC":".199","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-02-04"},{"SOURCE_ROW_NUMBER":"584983","CASS_NUM":"50633576","SMP_TAKEN_DT":"1/31/2002","CONC":".198","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-31"},{"SOURCE_ROW_NUMBER":"1556349","CASS_NUM":"50620385","SMP_TAKEN_DT":"1/30/2002","CONC":".842","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-30"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":4,"firstDate":"2001-04-05","lastDate":"2002-03-11","metrics":{"linkedIssuances":4},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":28,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":8,"firstDate":"1991-11-01","lastDate":"2006-11-17","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":6},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":53,"firstDate":"2000-03-09","lastDate":"2024-03-27","metrics":{"inspectors":81,"recentRows":1,"onSiteHours":883.75,"inspectionHours":1775.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"965592","EVENT_NO":"7034764","INSPECTION_BEGIN_DT":"03/27/2024","INSPECTION_END_DT":"03/27/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2024-03-27"},{"SOURCE_ROW_NUMBER":"941681","EVENT_NO":"7004492","INSPECTION_BEGIN_DT":"08/16/2018","INSPECTION_END_DT":"08/16/2018","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2018-08-16"},{"SOURCE_ROW_NUMBER":"922664","EVENT_NO":"4105903","INSPECTION_BEGIN_DT":"10/01/2003","INSPECTION_END_DT":"10/01/2003","ACTIVITY_CODE":"CCF","ACTIVITY":"WASTE PILE TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2003-10-01"},{"SOURCE_ROW_NUMBER":"502459","EVENT_NO":"4101051","INSPECTION_BEGIN_DT":"07/09/2002","INSPECTION_END_DT":"07/09/2002","ACTIVITY_CODE":"CCF","ACTIVITY":"WASTE PILE TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.75","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"594679","EVENT_NO":"4094249","INSPECTION_BEGIN_DT":"04/17/2002","INSPECTION_END_DT":"04/22/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2002-04-17"},{"SOURCE_ROW_NUMBER":"72518","EVENT_NO":"4092691","INSPECTION_BEGIN_DT":"04/05/2002","INSPECTION_END_DT":"05/20/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"26","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2002-04-05"},{"SOURCE_ROW_NUMBER":"657418","EVENT_NO":"4097979","INSPECTION_BEGIN_DT":"03/06/2002","INSPECTION_END_DT":"03/06/2002","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"902274","EVENT_NO":"4095518","INSPECTION_BEGIN_DT":"02/14/2002","INSPECTION_END_DT":"02/22/2002","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"63.5","SUM_TOTAL_ON_SITE_HOURS":"36","sourceDate":"2002-02-14"},{"SOURCE_ROW_NUMBER":"1077043","EVENT_NO":"4092682","INSPECTION_BEGIN_DT":"01/10/2002","INSPECTION_END_DT":"03/19/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"36","SUM_TOTAL_ON_SITE_HOURS":"17.5","sourceDate":"2002-01-10"},{"SOURCE_ROW_NUMBER":"681623","EVENT_NO":"4092683","INSPECTION_BEGIN_DT":"01/10/2002","INSPECTION_END_DT":"03/19/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"58.5","SUM_TOTAL_ON_SITE_HOURS":"31.75","sourceDate":"2002-01-10"},{"SOURCE_ROW_NUMBER":"1051144","EVENT_NO":"4092676","INSPECTION_BEGIN_DT":"12/17/2001","INSPECTION_END_DT":"01/08/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2001-12-17"},{"SOURCE_ROW_NUMBER":"43604","EVENT_NO":"4092675","INSPECTION_BEGIN_DT":"12/14/2001","INSPECTION_END_DT":"12/14/2001","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2001-12-14"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":18,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q2":{"hours":5025,"employees":49,"production":10059},"2002-Q1":{"hours":29987,"employees":49,"production":73223},"2001-Q4":{"hours":25543,"employees":46,"production":55801},"2001-Q3":{"hours":24242,"employees":43,"production":27645},"2001-Q2":{"hours":26102,"employees":50,"production":76139},"2001-Q1":{"hours":35557,"employees":50,"production":90863},"2000-Q4":{"hours":32119,"employees":46,"production":74459},"2000-Q3":{"hours":22671,"employees":46,"production":52090},"2000-Q2":{"hours":14647,"employees":33,"production":19594}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":69437,"employees":42,"production":146143},"2001":{"hours":111444,"employees":48,"production":250448},"2002":{"hours":35012,"employees":49,"production":83282}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":5,"firstDate":"2000-06-05","lastDate":"2000-06-05","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":399,"pelDoseTotal":312},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"235074","EVENT_NO":"4086325","SURVEY_DATE":"06/05/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"48","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2000-06-05"},{"SOURCE_ROW_NUMBER":"235073","EVENT_NO":"4086325","SURVEY_DATE":"06/05/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"123","PEL_DOSE_90":"106","SURVEY_TYPE":"I","sourceDate":"2000-06-05"},{"SOURCE_ROW_NUMBER":"235072","EVENT_NO":"4086325","SURVEY_DATE":"06/05/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"100","PEL_DOSE_90":"79","SURVEY_TYPE":"I","sourceDate":"2000-06-05"},{"SOURCE_ROW_NUMBER":"235071","EVENT_NO":"4086325","SURVEY_DATE":"06/05/2000","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"102","ACT_DOSE_85":"51","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2000-06-05"},{"SOURCE_ROW_NUMBER":"235070","EVENT_NO":"4086325","SURVEY_DATE":"06/05/2000","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"102","ACT_DOSE_85":"77","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2000-06-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":21,"firstDate":"2000-05-16","lastDate":"2002-04-02","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":14,"validSamples":19,"quartzPctTotal":132.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"77316","CASSETTE_NO":"50650911","SAMPLE_DT":"04/02/2002","QUARTZ_PCT":"14.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2002-04-02"},{"SOURCE_ROW_NUMBER":"11286","CASSETTE_NO":"57397560","SAMPLE_DT":"03/15/2002","QUARTZ_PCT":"10.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"38265","CASSETTE_NO":"57376305","SAMPLE_DT":"12/17/2001","QUARTZ_PCT":"08.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-17"},{"SOURCE_ROW_NUMBER":"17468","CASSETTE_NO":"57356824","SAMPLE_DT":"11/14/2001","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-14"},{"SOURCE_ROW_NUMBER":"110976","CASSETTE_NO":"57334029","SAMPLE_DT":"07/24/2001","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-07-24"},{"SOURCE_ROW_NUMBER":"152409","CASSETTE_NO":"57303447","SAMPLE_DT":"05/09/2001","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-09"},{"SOURCE_ROW_NUMBER":"123699","CASSETTE_NO":"57303524","SAMPLE_DT":"05/09/2001","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-09"},{"SOURCE_ROW_NUMBER":"55450","CASSETTE_NO":"57295012","SAMPLE_DT":"03/19/2001","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-19"},{"SOURCE_ROW_NUMBER":"36601","CASSETTE_NO":"57294972","SAMPLE_DT":"03/19/2001","QUARTZ_PCT":"09.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-19"},{"SOURCE_ROW_NUMBER":"10839","CASSETTE_NO":"57294699","SAMPLE_DT":"01/23/2001","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"945","CASSETTE_NO":"57294697","SAMPLE_DT":"01/23/2001","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-23"},{"SOURCE_ROW_NUMBER":"98744","CASSETTE_NO":"57294695","SAMPLE_DT":"01/22/2001","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":156,"firstDate":"2000-03-23","lastDate":"2002-03-11","metrics":{"ss":56,"amountDue":13296,"contested":0,"amountPaid":9508.69,"recentRows":0,"section104d":1,"unterminated":1,"proposedPenalty":13296},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2697805","VIOLATION_NO":"7193821","VIOLATION_ISSUE_DT":"03/11/2002","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/11/2002","PROPOSED_PENALTY":"173","AMOUNT_DUE":"173","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-11"},{"SOURCE_ROW_NUMBER":"2697804","VIOLATION_NO":"7193820","VIOLATION_ISSUE_DT":"03/11/2002","SIG_SUB":"N","PART_SECTION":"75.807","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-11"},{"SOURCE_ROW_NUMBER":"2697803","VIOLATION_NO":"7193819","VIOLATION_ISSUE_DT":"03/06/2002","SIG_SUB":"N","PART_SECTION":"77.207","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/12/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"2697802","VIOLATION_NO":"7193818","VIOLATION_ISSUE_DT":"03/06/2002","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/06/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"2697801","VIOLATION_NO":"7193817","VIOLATION_ISSUE_DT":"03/06/2002","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/06/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"2697800","VIOLATION_NO":"7193816","VIOLATION_ISSUE_DT":"03/06/2002","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/06/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"2697799","VIOLATION_NO":"7193815","VIOLATION_ISSUE_DT":"03/06/2002","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/06/2002","PROPOSED_PENALTY":"122","AMOUNT_DUE":"122","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-06"},{"SOURCE_ROW_NUMBER":"2697798","VIOLATION_NO":"7193814","VIOLATION_ISSUE_DT":"03/05/2002","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/06/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"2697797","VIOLATION_NO":"7193812","VIOLATION_ISSUE_DT":"03/05/2002","SIG_SUB":"N","PART_SECTION":"75.1103","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/06/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"2697812","VIOLATION_NO":"7211040","VIOLATION_ISSUE_DT":"02/15/2002","SIG_SUB":"Y","PART_SECTION":"75.1200","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"8","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/07/2002","PROPOSED_PENALTY":"259","AMOUNT_DUE":"259","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-02-15"},{"SOURCE_ROW_NUMBER":"2697811","VIOLATION_NO":"7211039","VIOLATION_ISSUE_DT":"02/15/2002","SIG_SUB":"Y","PART_SECTION":"75.388(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"8","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"03/07/2002","PROPOSED_PENALTY":"1270","AMOUNT_DUE":"1270","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-02-15"},{"SOURCE_ROW_NUMBER":"2697810","VIOLATION_NO":"7211038","VIOLATION_ISSUE_DT":"02/14/2002","SIG_SUB":"N","PART_SECTION":"50.10","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/14/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-02-14"}]}],"safety":{"href":"/api/v1/mines/4608137/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4608137/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.807","heading":"Installation of high-voltage transmission cables.","id":"75.807","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.807","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"I","subpartHeading":"Subpart I—Underground High-Voltage Distribution","text":"[Statutory Provisions]\n\nAll underground high-voltage transmission cables shall be installed only in regularly inspected air courses and haulageways, and shall be covered, buried, or placed so as to afford protection against damage, guarded where men regularly work or pass under them unless they are 6 1/2 feet or more above the floor or rail, securely anchored, properly insulated, and guarded at ends, and covered, insulated, or placed to prevent contact with trolley wires and other low-voltage circuits.","occurrenceCount":1},{"chapter":"I","heading":"Illumination.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.207","part":"77","subchapter":"O","subpart":"C","id":"77.207","citation":"30 CFR 77.207","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Automatic fire warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103","part":"75","subchapter":"O","subpart":"L","id":"75.1103","citation":"30 CFR 75.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Mine map.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1200","part":"75","subchapter":"O","subpart":"M","id":"75.1200","citation":"30 CFR 75.1200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Boreholes in advance of mining.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.388","part":"75","subchapter":"O","subpart":"D","id":"75.388","citation":"30 CFR 75.388","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 50.10","heading":"Immediate notification.","id":"50.10","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-B/section-50.10","part":"50","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subchapter":"I","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","subpart":"B","subpartHeading":"Subpart B—Notification, Investigation, Preservation of Evidence","text":"The operator shall immediately contact MSHA at once without delay and within 15 minutes at the toll-free number, 1-800-746-1553, once the operator knows or should know that an accident has occurred involving:\n\n(a) A death of an individual at the mine;\n\n(b) An injury of an individual at the mine which has a reasonable potential to cause death;\n\n(c) An entrapment of an individual at the mine which has a reasonable potential to cause death; or\n\n(d) Any other accident.\n\n[74 FR 68919, Dec. 29, 2009]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4608137","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}