{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4607908","name":"Big Mountain No 16","status":"Abandoned and Sealed","status_date":"2014-10-29","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Prenter","operator_id":"P24179","operator_name":"Pine Ridge Coal Company LLC","controller_id":"0071611","controller_name":"Patriot Coal Corporation","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":38.006944,"longitude":-81.639722},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":11278},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4607908","name":"Big Mountain No 16"},"operator":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company LLC"},"controller":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"mine","id":"4607908","name":"Big Mountain No 16"},"validFrom":"1984-02-27","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|C05313|1984-02-27|1998-05-18"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22944","name":"Pine Ridge Coal Company"},"object":{"type":"mine","id":"4607908","name":"Big Mountain No 16"},"validFrom":"1990-07-01","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|P22944|1990-07-01|1998-05-18"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"operator","id":"P22944","name":"Pine Ridge Coal Company"},"validFrom":"1990-07-01","validTo":"1998-05-18","current":false,"derived":true,"evidenceMineId":"4607908","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|P22944|1990-07-01|C05313|1984-02-27|68309"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company LLC"},"object":{"type":"mine","id":"4607908","name":"Big Mountain No 16"},"validFrom":"1998-05-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|P24179|1998-05-19|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"4607908","name":"Big Mountain No 16"},"validFrom":"1998-05-19","validTo":"2007-10-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|C15833|1998-05-19|2007-10-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company LLC"},"validFrom":"1998-05-19","validTo":"2007-10-30","current":false,"derived":true,"evidenceMineId":"4607908","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|P24179|1998-05-19|C15833|1998-05-19|96963"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"mine","id":"4607908","name":"Big Mountain No 16"},"validFrom":"2007-10-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|0071611|2007-10-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company LLC"},"validFrom":"2007-10-31","validTo":null,"current":true,"derived":true,"evidenceMineId":"4607908","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607908|P24179|1998-05-19|0071611|2007-10-31|10299"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":340,"firstDate":"2000-01-07","lastDate":"2012-01-11","metrics":{"daysLost":11022,"injuries":287,"fatalities":0,"recentRows":0,"restrictedDays":74,"contractorRecords":8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"12367","DOCUMENT_NO":"220120240042","ACCIDENT_DT":"01/11/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"16","NARRATIVE":"Employee was passing through the man door under the A-Belt overcast and his right foot stuck in the door. This caused him to lose his balance. As he stumbled, he twisted his right knee and fell to the mine floor.","sourceDate":"2012-01-11"},{"SOURCE_ROW_NUMBER":"210174","DOCUMENT_NO":"220120050027","ACCIDENT_DT":"12/29/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"Employee was installing roof bolts and as he was removing the drill steel from the bolt hole the drill steel struck his right middle finger.","sourceDate":"2011-12-29"},{"SOURCE_ROW_NUMBER":"59520","DOCUMENT_NO":"220120860058","ACCIDENT_DT":"12/19/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While tightening bolt on railroad switch, finger caught between bolt and rail when impact wrench applied.  Crushing injury, right hand, middle finger.  Employee missed no work, was placed on restricted duty until 1/24/12 when reevaluated by doctor.","sourceDate":"2011-12-19"},{"SOURCE_ROW_NUMBER":"180067","DOCUMENT_NO":"220113470001","ACCIDENT_DT":"12/12/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Rodman, Surveyor/Transit helper","NO_INJURIES":"2","DAYS_LOST":"9","NARRATIVE":"Check top and rib before taking coal section. EE noticed rock coal shell chunk started coming off rib and EE pushed IE out of the way. Chunk of coal hit IE first, then a piece of coal fell on EE's ankle.","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"3766","DOCUMENT_NO":"220113470002","ACCIDENT_DT":"12/12/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Transit man, Surveyor/Transit worker","NO_INJURIES":"2","DAYS_LOST":"0","NARRATIVE":"Check top and rib before taking coal section. IE noticed rock coal shell chunk started coming off rib and IE pushed EE out of the way. Chunk of coal hit EE first, then a piece of coal fell on IE's ankle.","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"85379","DOCUMENT_NO":"220113560020","ACCIDENT_DT":"12/09/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"Employee stated that he stepped in a water hole while dismounting the coal hauler he was operating and twisted his left leg.","sourceDate":"2011-12-09"},{"SOURCE_ROW_NUMBER":"175788","DOCUMENT_NO":"220113250027","ACCIDENT_DT":"11/07/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"15","NARRATIVE":"Employee stated that he slipped on a roof bolt strap as he was walking to the rear of the roof bolting machine to get roof bolts and fell forward and twisted his lower back as he tried to catch himself.","sourceDate":"2011-11-07"},{"SOURCE_ROW_NUMBER":"89672","DOCUMENT_NO":"220113010013","ACCIDENT_DT":"10/20/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"Employee was installing roof bolts and as he reached up to turn the roof bolt plate as it was spinning and being pushed upward, his hand came in contact with the plate and it caused a laceration to his left middle finger.","sourceDate":"2011-10-20"},{"SOURCE_ROW_NUMBER":"266083","DOCUMENT_NO":"220112790012","ACCIDENT_DT":"09/08/2011","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Diagnosis of Occupational Hearing Loss, received on 10-04-2011.  Employee is off work as a result of an injury at the time of the hearing loss diagnosis, therefore he is not off work related to his hearing loss.","sourceDate":"2011-09-08"},{"SOURCE_ROW_NUMBER":"59528","DOCUMENT_NO":"220112450014","ACCIDENT_DT":"08/29/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Continuous miner helper, Coal mole helper, Bridgeman","NO_INJURIES":"1","DAYS_LOST":"54","NARRATIVE":"Employee was assisting the loader operator in cleaning up supply yard. As the loader operator was scooping up mud and debris the bucket struck the end of a timber causing it to swing around and strike the injured employee in the legs causing him to fall.  As he fell he extended his right arm out to break his fall causing his shoulder to dislocate.","sourceDate":"2011-08-29"},{"SOURCE_ROW_NUMBER":"106618","DOCUMENT_NO":"220112450017","ACCIDENT_DT":"08/27/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Apprentice, Trainee","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"Employee was helping build cribs and some small wood was needed to cap and wedge the last crib. Employee was using a block hammer as a chisel and a pick hammer to drive the block hammer in between nailed wood of a pallet and as the employee struck the block hammer with the pick hammer, a piece of metal flew off of the pick hammer and struck and embedded in his left arm.","sourceDate":"2011-08-27"},{"SOURCE_ROW_NUMBER":"20914","DOCUMENT_NO":"220112360030","ACCIDENT_DT":"08/11/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"46","NARRATIVE":"Employee stated that he slipped while stepping from roof bolting machine operator platform to the machine platform and fell and struck his back on machine.","sourceDate":"2011-08-11"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-10-29","lastDate":"2014-10-29","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2524,"firstDate":"2000-01-20","lastDate":"2014-06-23","metrics":{"ss":996,"delinquent":2313,"recentRows":0,"paidPenalty":2692547.05,"proposedPenalty":4195815,"currentAssessment":2692547.15},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1843490","VIOLATION_NO":"8154137","ISSUE_DT":"06/23/2014","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-06-23"},{"SOURCE_ROW_NUMBER":"1859688","VIOLATION_NO":"7166742","ISSUE_DT":"05/29/2013","CFR_STANDARD_CD":"72.520(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-05-29"},{"SOURCE_ROW_NUMBER":"1814828","VIOLATION_NO":"8146297","ISSUE_DT":"06/18/2012","CFR_STANDARD_CD":"77.1103(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"1811483","VIOLATION_NO":"8148009","ISSUE_DT":"02/08/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"234.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"1811482","VIOLATION_NO":"8148004","ISSUE_DT":"01/31/2012","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"687.00","CURRENT_ASSESSMENT_AMT":"481.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"1811481","VIOLATION_NO":"8148003","ISSUE_DT":"01/31/2012","CFR_STANDARD_CD":"75.1722(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3143.00","CURRENT_ASSESSMENT_AMT":"2200.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"1811480","VIOLATION_NO":"8148002","ISSUE_DT":"01/31/2012","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"6996.00","CURRENT_ASSESSMENT_AMT":"4897.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"1811479","VIOLATION_NO":"8148001","ISSUE_DT":"01/30/2012","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"522.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-30"},{"SOURCE_ROW_NUMBER":"1811478","VIOLATION_NO":"8148000","ISSUE_DT":"01/30/2012","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"522.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-30"},{"SOURCE_ROW_NUMBER":"1811477","VIOLATION_NO":"8147999","ISSUE_DT":"01/26/2012","CFR_STANDARD_CD":"75.1714-4(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3143.00","CURRENT_ASSESSMENT_AMT":"2200.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-26"},{"SOURCE_ROW_NUMBER":"1811476","VIOLATION_NO":"8147998","ISSUE_DT":"01/26/2012","CFR_STANDARD_CD":"75.1714-7(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"687.00","CURRENT_ASSESSMENT_AMT":"687.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-26"},{"SOURCE_ROW_NUMBER":"1811475","VIOLATION_NO":"8147997","ISSUE_DT":"01/25/2012","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3405.00","CURRENT_ASSESSMENT_AMT":"2384.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-25"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":846,"firstDate":"2003-06-03","lastDate":"2013-06-11","metrics":{"appeals":2,"decisions":846,"recentRows":0,"decisionPenalty":2178506.15,"originalPenalty":3895776},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"27115","VIOLATION_NO":"7269756","DOCKET_NO":"WEVA 2008-1623","DECISION_DT":"06/11/2013","DECISION_TYPE_CODE_DESC":"Prevail","ORIGINAL_PENALTY_AMT":"45000.00","DECISION_PENALTY_AMT":"36000.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"27075","VIOLATION_NO":"7269757","DOCKET_NO":"WEVA 2008-1623","DECISION_DT":"06/11/2013","DECISION_TYPE_CODE_DESC":"Prevail","ORIGINAL_PENALTY_AMT":"45000.00","DECISION_PENALTY_AMT":"36000.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"328085","VIOLATION_NO":"8146091","DOCKET_NO":"WEVA 2012-1342","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"44645.00","DECISION_PENALTY_AMT":"27000.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"328008","VIOLATION_NO":"8147994","DOCKET_NO":"WEVA 2012-1342","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"20302.00","DECISION_PENALTY_AMT":"10000.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"327109","VIOLATION_NO":"8148000","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"522.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"327031","VIOLATION_NO":"8148001","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"522.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"326980","VIOLATION_NO":"8147982","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1731.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"326937","VIOLATION_NO":"8148009","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"234.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"326936","VIOLATION_NO":"8146085","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"778.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"326935","VIOLATION_NO":"8146080","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8893.00","DECISION_PENALTY_AMT":"6225.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"326445","VIOLATION_NO":"8137604","DOCKET_NO":"WEVA 2012-1244","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"15971.00","DECISION_PENALTY_AMT":"10000.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"326205","VIOLATION_NO":"8147997","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"2384.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2013-02-12"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1928,"firstDate":"2000-01-20","lastDate":"2012-12-29","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":161,"validSamples":1767,"maxConcentration":12.161,"concentrationTotal":1422.19},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"633574","CASS_NUM":"51143875","SMP_TAKEN_DT":"12/29/2012","CONC":".153","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-12-29"},{"SOURCE_ROW_NUMBER":"164278","CASS_NUM":"51143882","SMP_TAKEN_DT":"1/31/2012","CONC":".424","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"884633","CASS_NUM":"51143868","SMP_TAKEN_DT":"1/24/2012","CONC":".424","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-24"},{"SOURCE_ROW_NUMBER":"1570615","CASS_NUM":"57936977","SMP_TAKEN_DT":"1/17/2012","CONC":".56","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"1453676","CASS_NUM":"57937116","SMP_TAKEN_DT":"1/17/2012","CONC":".668","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"1349592","CASS_NUM":"57936837","SMP_TAKEN_DT":"1/17/2012","CONC":".753","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"793984","CASS_NUM":"57936882","SMP_TAKEN_DT":"1/17/2012","CONC":".67","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"430441","CASS_NUM":"57936952","SMP_TAKEN_DT":"1/17/2012","CONC":".348","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"290748","CASS_NUM":"57936898","SMP_TAKEN_DT":"1/17/2012","CONC":".723","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"9294","CASS_NUM":"57936936","SMP_TAKEN_DT":"1/17/2012","CONC":".188","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"1644584","CASS_NUM":"51143883","SMP_TAKEN_DT":"12/30/2011","CONC":".352","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-30"},{"SOURCE_ROW_NUMBER":"1320126","CASS_NUM":"51143874","SMP_TAKEN_DT":"12/29/2011","CONC":".197","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-29"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":40,"firstDate":"2000-10-05","lastDate":"2012-02-27","metrics":{"linkedIssuances":40},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":841,"firstDate":"2006-02-08","lastDate":"2012-02-08","metrics":{"decisions":841,"ssChanged":219,"recentRows":0,"decisionPenalty":2087315.15,"proposedPenalty":3803675},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"26034","CITATION_NO":"8148009","CITATION_ISSUE_DT":"02/08/2012","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"234.00","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"196216","CITATION_NO":"8148002","CITATION_ISSUE_DT":"01/31/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6996.00","DECISION_PENALTY_AMT":"4897.00","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"27315","CITATION_NO":"8148004","CITATION_ISSUE_DT":"01/31/2012","DOCKET_NO":"WEVA 2012-1084","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"481.00","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"26750","CITATION_NO":"8148003","CITATION_ISSUE_DT":"01/31/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.1722(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2200.00","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"83809","CITATION_NO":"8148000","CITATION_ISSUE_DT":"01/30/2012","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.333(h)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"522.00","sourceDate":"2012-01-30"},{"SOURCE_ROW_NUMBER":"83808","CITATION_NO":"8148001","CITATION_ISSUE_DT":"01/30/2012","DOCKET_NO":"WEVA 2012-1451","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.333(h)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"522.00","sourceDate":"2012-01-30"},{"SOURCE_ROW_NUMBER":"425841","CITATION_NO":"8147999","CITATION_ISSUE_DT":"01/26/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.1714-4(a)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2200.00","sourceDate":"2012-01-26"},{"SOURCE_ROW_NUMBER":"423355","CITATION_NO":"8146099","CITATION_ISSUE_DT":"01/25/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4329.00","DECISION_PENALTY_AMT":"3030.00","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"423028","CITATION_NO":"8147997","CITATION_ISSUE_DT":"01/25/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"2384.00","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"139557","CITATION_NO":"8146100","CITATION_ISSUE_DT":"01/25/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"2384.00","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"138625","CITATION_NO":"8146098","CITATION_ISSUE_DT":"01/25/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4521.00","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"26999","CITATION_NO":"8146101","CITATION_ISSUE_DT":"01/25/2012","DOCKET_NO":"WEVA 2012-1215","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.606","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"2384.00","sourceDate":"2012-01-25"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1225,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":11,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":244,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":10,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1990-07-01","lastDate":"1998-05-19","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":189,"firstDate":"2000-01-10","lastDate":"2014-10-06","metrics":{"inspectors":414,"recentRows":0,"onSiteHours":13665.25,"inspectionHours":19790,"inspectionSamples":1485},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1129389","EVENT_NO":"6308613","INSPECTION_BEGIN_DT":"10/06/2014","INSPECTION_END_DT":"10/06/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2014-10-06"},{"SOURCE_ROW_NUMBER":"796594","EVENT_NO":"6309112","INSPECTION_BEGIN_DT":"08/12/2014","INSPECTION_END_DT":"08/28/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2014-08-12"},{"SOURCE_ROW_NUMBER":"475961","EVENT_NO":"6298299","INSPECTION_BEGIN_DT":"05/15/2014","INSPECTION_END_DT":"06/26/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"24.5","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"695177","EVENT_NO":"6299027","INSPECTION_BEGIN_DT":"02/27/2014","INSPECTION_END_DT":"03/05/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2014-02-27"},{"SOURCE_ROW_NUMBER":"456258","EVENT_NO":"6302515","INSPECTION_BEGIN_DT":"11/26/2013","INSPECTION_END_DT":"11/26/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2013-11-26"},{"SOURCE_ROW_NUMBER":"792137","EVENT_NO":"6302210","INSPECTION_BEGIN_DT":"07/11/2013","INSPECTION_END_DT":"07/15/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"1020874","EVENT_NO":"6302204","INSPECTION_BEGIN_DT":"05/29/2013","INSPECTION_END_DT":"06/11/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"42","SUM_TOTAL_ON_SITE_HOURS":"17.25","sourceDate":"2013-05-29"},{"SOURCE_ROW_NUMBER":"588296","EVENT_NO":"6293148","INSPECTION_BEGIN_DT":"01/03/2013","INSPECTION_END_DT":"01/07/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"828281","EVENT_NO":"6293139","INSPECTION_BEGIN_DT":"10/15/2012","INSPECTION_END_DT":"10/15/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2012-10-15"},{"SOURCE_ROW_NUMBER":"346480","EVENT_NO":"6297170","INSPECTION_BEGIN_DT":"09/05/2012","INSPECTION_END_DT":"09/06/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"173933","EVENT_NO":"6292774","INSPECTION_BEGIN_DT":"06/11/2012","INSPECTION_END_DT":"06/19/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"700048","EVENT_NO":"6291788","INSPECTION_BEGIN_DT":"02/06/2012","INSPECTION_END_DT":"03/12/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"90.5","SUM_TOTAL_ON_SITE_HOURS":"56","sourceDate":"2012-02-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":167,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014-Q3":{"hours":0,"employees":0,"production":0},"2014-Q2":{"hours":0,"employees":0,"production":0},"2014-Q1":{"hours":0,"employees":0,"production":0},"2013-Q4":{"hours":0,"employees":0,"production":0},"2013-Q3":{"hours":0,"employees":0,"production":0},"2013-Q2":{"hours":0,"employees":0,"production":0},"2013-Q1":{"hours":0,"employees":0,"production":0},"2012-Q3":{"hours":480,"employees":1,"production":0},"2012-Q1":{"hours":57684,"employees":94,"production":53756},"2011-Q4":{"hours":125602,"employees":211,"production":272294},"2011-Q3":{"hours":127865,"employees":215,"production":255933},"2011-Q2":{"hours":119161,"employees":206,"production":278998}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003":{"hours":266926,"employees":122,"production":1199490},"2004":{"hours":304967,"employees":134,"production":1308236},"2005":{"hours":304301,"employees":132,"production":1082250},"2006":{"hours":328377,"employees":135,"production":1089239},"2007":{"hours":375941,"employees":156,"production":995212},"2008":{"hours":437567,"employees":175,"production":1081481},"2009":{"hours":451091,"employees":189,"production":986174},"2010":{"hours":487673,"employees":206,"production":986278},"2011":{"hours":498917,"employees":208,"production":1078515},"2012":{"hours":58164,"employees":94,"production":53756}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":158,"firstDate":"2000-01-27","lastDate":"2011-10-31","metrics":{"recentRows":0,"doseOver100":45,"actDoseTotal":64521,"pelDoseTotal":52519},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"234114","EVENT_NO":"6289100","SURVEY_DATE":"10/31/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"102","ACT_DOSE_85":"75","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2011-10-31"},{"SOURCE_ROW_NUMBER":"234113","EVENT_NO":"6289100","SURVEY_DATE":"10/31/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"102","ACT_DOSE_85":"76","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2011-10-31"},{"SOURCE_ROW_NUMBER":"234112","EVENT_NO":"6289100","SURVEY_DATE":"10/31/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"83","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2011-10-31"},{"SOURCE_ROW_NUMBER":"234111","EVENT_NO":"6289100","SURVEY_DATE":"10/31/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"87","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2011-10-31"},{"SOURCE_ROW_NUMBER":"234110","EVENT_NO":"6289100","SURVEY_DATE":"10/31/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"85","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2011-10-31"},{"SOURCE_ROW_NUMBER":"234119","EVENT_NO":"6289100","SURVEY_DATE":"10/24/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"85","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"234118","EVENT_NO":"6289100","SURVEY_DATE":"10/24/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"82","PEL_DOSE_90":"81","SURVEY_TYPE":"I","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"234117","EVENT_NO":"6289100","SURVEY_DATE":"10/24/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"86","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"234116","EVENT_NO":"6289100","SURVEY_DATE":"10/24/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"87","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"234115","EVENT_NO":"6289100","SURVEY_DATE":"10/24/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"93","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"234109","EVENT_NO":"6289100","SURVEY_DATE":"10/17/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"96","PEL_DOSE_90":"94","SURVEY_TYPE":"I","sourceDate":"2011-10-17"},{"SOURCE_ROW_NUMBER":"234108","EVENT_NO":"6289100","SURVEY_DATE":"10/17/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"97","PEL_DOSE_90":"91","SURVEY_TYPE":"I","sourceDate":"2011-10-17"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":182,"firstDate":"2000-01-20","lastDate":"2012-01-17","metrics":{"recentRows":0,"voidSamples":12,"maxQuartzPct":40.4,"validSamples":170,"quartzPctTotal":2013.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"122856","CASSETTE_NO":"57936898","SAMPLE_DT":"01/17/2012","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"31318","CASSETTE_NO":"51144139","SAMPLE_DT":"12/22/2011","QUARTZ_PCT":"13.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-22"},{"SOURCE_ROW_NUMBER":"153496","CASSETTE_NO":"51144110","SAMPLE_DT":"12/06/2011","QUARTZ_PCT":"15.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-06"},{"SOURCE_ROW_NUMBER":"144980","CASSETTE_NO":"57936769","SAMPLE_DT":"11/16/2011","QUARTZ_PCT":"09.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-16"},{"SOURCE_ROW_NUMBER":"44665","CASSETTE_NO":"57936750","SAMPLE_DT":"11/16/2011","QUARTZ_PCT":"21.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-16"},{"SOURCE_ROW_NUMBER":"47966","CASSETTE_NO":"57908200","SAMPLE_DT":"09/19/2011","QUARTZ_PCT":"21.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-19"},{"SOURCE_ROW_NUMBER":"151421","CASSETTE_NO":"51114825","SAMPLE_DT":"08/09/2011","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-09"},{"SOURCE_ROW_NUMBER":"91964","CASSETTE_NO":"51114874","SAMPLE_DT":"06/07/2011","QUARTZ_PCT":"21.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-06-07"},{"SOURCE_ROW_NUMBER":"82362","CASSETTE_NO":"57887036","SAMPLE_DT":"05/17/2011","QUARTZ_PCT":"19.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-17"},{"SOURCE_ROW_NUMBER":"70885","CASSETTE_NO":"57911862","SAMPLE_DT":"02/23/2011","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-23"},{"SOURCE_ROW_NUMBER":"124394","CASSETTE_NO":"51053125","SAMPLE_DT":"12/21/2010","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-12-21"},{"SOURCE_ROW_NUMBER":"109289","CASSETTE_NO":"57882483","SAMPLE_DT":"10/12/2010","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":2559,"firstDate":"2000-01-20","lastDate":"2014-06-23","metrics":{"ss":997,"amountDue":2692547.15,"contested":600,"amountPaid":2692547.05,"recentRows":0,"section104d":33,"unterminated":11,"proposedPenalty":4195815},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2689923","VIOLATION_NO":"8154137","VIOLATION_ISSUE_DT":"06/23/2014","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/24/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-06-23"},{"SOURCE_ROW_NUMBER":"2689926","VIOLATION_NO":"7166742","VIOLATION_ISSUE_DT":"05/29/2013","SIG_SUB":"N","PART_SECTION":"72.520(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/05/2013","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2013-05-29"},{"SOURCE_ROW_NUMBER":"2689927","VIOLATION_NO":"8146297","VIOLATION_ISSUE_DT":"06/18/2012","SIG_SUB":"N","PART_SECTION":"77.1103(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/19/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-18"},{"SOURCE_ROW_NUMBER":"2689253","VIOLATION_NO":"8148009","VIOLATION_ISSUE_DT":"02/08/2012","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2012","PROPOSED_PENALTY":"334","AMOUNT_DUE":"234","AMOUNT_PAID":"234","CONTESTED_IND":"N","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"2688880","VIOLATION_NO":"8148004","VIOLATION_ISSUE_DT":"01/31/2012","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/31/2012","PROPOSED_PENALTY":"687","AMOUNT_DUE":"481","AMOUNT_PAID":"481","CONTESTED_IND":"N","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"2688879","VIOLATION_NO":"8148003","VIOLATION_ISSUE_DT":"01/31/2012","SIG_SUB":"Y","PART_SECTION":"75.1722(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/31/2012","PROPOSED_PENALTY":"3143","AMOUNT_DUE":"2200","AMOUNT_PAID":"2200","CONTESTED_IND":"N","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"2688878","VIOLATION_NO":"8148002","VIOLATION_ISSUE_DT":"01/31/2012","SIG_SUB":"Y","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"14","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/31/2012","PROPOSED_PENALTY":"6996","AMOUNT_DUE":"4897","AMOUNT_PAID":"4897","CONTESTED_IND":"N","sourceDate":"2012-01-31"},{"SOURCE_ROW_NUMBER":"2688877","VIOLATION_NO":"8148001","VIOLATION_ISSUE_DT":"01/30/2012","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/06/2012","PROPOSED_PENALTY":"745","AMOUNT_DUE":"522","AMOUNT_PAID":"522","CONTESTED_IND":"N","sourceDate":"2012-01-30"},{"SOURCE_ROW_NUMBER":"2688876","VIOLATION_NO":"8148000","VIOLATION_ISSUE_DT":"01/30/2012","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/30/2012","PROPOSED_PENALTY":"745","AMOUNT_DUE":"522","AMOUNT_PAID":"522","CONTESTED_IND":"N","sourceDate":"2012-01-30"},{"SOURCE_ROW_NUMBER":"2688875","VIOLATION_NO":"8147999","VIOLATION_ISSUE_DT":"01/26/2012","SIG_SUB":"Y","PART_SECTION":"75.1714-4(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/06/2012","PROPOSED_PENALTY":"3143","AMOUNT_DUE":"2200","AMOUNT_PAID":"2200","CONTESTED_IND":"N","sourceDate":"2012-01-26"},{"SOURCE_ROW_NUMBER":"2688874","VIOLATION_NO":"8147998","VIOLATION_ISSUE_DT":"01/26/2012","SIG_SUB":"N","PART_SECTION":"75.1714-7(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/26/2012","PROPOSED_PENALTY":"687","AMOUNT_DUE":"687","AMOUNT_PAID":"687","CONTESTED_IND":"N","sourceDate":"2012-01-26"},{"SOURCE_ROW_NUMBER":"2688873","VIOLATION_NO":"8147997","VIOLATION_ISSUE_DT":"01/25/2012","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/25/2012","PROPOSED_PENALTY":"3405","AMOUNT_DUE":"2384","AMOUNT_PAID":"2384","CONTESTED_IND":"N","sourceDate":"2012-01-25"}]}],"safety":{"href":"/api/v1/mines/4607908/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4607908/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Diesel equipment inventory.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-D/section-72.520","part":"72","subchapter":"O","subpart":"D","id":"72.520","citation":"30 CFR 72.520","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-4","heading":"Additional self-contained self-rescuers (SCSRs).","id":"75.1714-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:\n\n(1) At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.\n\n(2) Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.\n\n(b) Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.\n\n(c) Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.\n\n(1) Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.\n\n(2) Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—\n\n(i) Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or\n\n(ii) Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.\n\nAverage entry height Maximum distancebetween SCSR storage locations (in ft.) <40 in. (Crawl) 2,200 >40-<50 in. (Duck Walk) 3,300 >50-<65 in. (Walk Head Bent) 4,400 >65 in. (Walk Erect) 5,700\n\n(d) Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.\n\n(1) The hardened room shall be designed and constructed to the same explosion force criteria as seals.\n\n(2) The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.\n\n(3) The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.\n\n(4) These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.\n\n(e) Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.\n\n(f) Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Multi-gas detectors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-7","part":"75","subchapter":"O","subpart":"R","id":"75.1714-7","citation":"30 CFR 75.1714-7","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4607908","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}