{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4607509","name":"Amherst Loading Facility","status":"Abandoned","status_date":"2026-06-30","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Kanawha","nearest_town":"Malden","operator_id":"P17110","operator_name":"Amherst Industries Inc","controller_id":"C00168","controller_name":"H E  Jones Jr; Charles T  Jones","district":"C04","office":"Mt. Carbon WV Field Office","employees":0,"latitude":38.302778,"longitude":-81.543611},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":932},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4607509","name":"Amherst Loading Facility"},"operator":{"type":"operator","id":"P17110","name":"Amherst Industries Inc"},"controller":{"type":"controller","id":"C00168","name":"H E  Jones Jr; Charles T  Jones"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00168","name":"H E  Jones Jr et al"},"object":{"type":"mine","id":"4607509","name":"Amherst Loading Facility"},"validFrom":"1985-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607509|C00168|1985-08-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17110","name":"Amherst Industries Inc"},"object":{"type":"mine","id":"4607509","name":"Amherst Loading Facility"},"validFrom":"1988-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607509|P17110|1988-05-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00168","name":"H E  Jones Jr et al"},"object":{"type":"operator","id":"P17110","name":"Amherst Industries Inc"},"validFrom":"1988-05-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4607509","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607509|P17110|1988-05-01|C00168|1985-08-01|44658"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00168","name":"Charles T  Jones et al"},"object":{"type":"operator","id":"P17110","name":"Amherst Industries Inc"},"validFrom":"1988-05-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4607509","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4607509|P17110|1988-05-01|C00168|1985-08-01|44659"}}],"coverage":{"historyRecords":2,"edgeCount":4,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":6,"firstDate":"2000-08-14","lastDate":"2003-07-31","metrics":{"daysLost":614,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"257537","DOCUMENT_NO":"220032170007","ACCIDENT_DT":"07/31/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Tipple/Top lander/Skip dumper operator, Binman, Topman","NO_INJURIES":"1","DAYS_LOST":"231","NARRATIVE":"EE WAS CHANGING OUT BARGES. HE CLIMBED A LADDER FROM THE LOADED BARGE TO THE EMPTY BARGE. HE WALKED TO THE BOW END OF THE BARGE, WHERE HE HAD A LOWER BACK SPASM. WE TOOK HIM FROM THE BARGE TO THE DR.","sourceDate":"2003-07-31"},{"SOURCE_ROW_NUMBER":"158543","DOCUMENT_NO":"220030240020","ACCIDENT_DT":"01/13/2003","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"THE COAL FEEDER WAS FROZEN DUE TO COLD TEMPERATURES. EE WAS PULLING ON THE V-BELTS TO GET THE FEEDER DISLODGED. WHEN THE PITMAN ARM WAS FULLY EXTENDED THE FEEDER RELEASED & PULLED EE'S RIGHT T HUMB BETWEEN THE BELT & PULLEY CLOSEST TO THE ELECTRIC MOTOR. AT THIS TIME ALL SOURCES OF POWER TO THIS ONE FEEDER WERE DISCONNECTED. EE'S TOP PORTION OF RIGHT THUMB WAS SEVERED.","sourceDate":"2003-01-13"},{"SOURCE_ROW_NUMBER":"201430","DOCUMENT_NO":"220021190071","ACCIDENT_DT":"04/19/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"59","NARRATIVE":"EE HAD CLIMBED UP ONTO THE ENDLOADER THAT HE WOULD BE OPERATING FOR HIS SHIFT. UPON REACHING THE TOP OF THE ENDLOADER HE SLIPPED AND FELL TO THE GROUND HE BRUISED HIS LOWER BACK AND RECEIVED A KNOT ON HIS HEAD. THE SURFACE THAT HE FELL ONTO WAS GRAVEL. THE HEIGHT THAT HE FELL WAS SEVEN FEET OFF OF THE GROUND.","sourceDate":"2002-04-19"},{"SOURCE_ROW_NUMBER":"29492","DOCUMENT_NO":"220011090011","ACCIDENT_DT":"01/14/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"274","NARRATIVE":"WHILE WELDING ON A SUPPORT FOR THE BARGE MOVER EE SITS ON HIS LEFT LEG AND HEARS THE KNEE POP. HE IS NOT OPERATED ON UNTIL MARCH 6, 2001. AT THIS TIME HE IS STILL OFF WORK.","sourceDate":"2001-01-14"},{"SOURCE_ROW_NUMBER":"253200","DOCUMENT_NO":"220010290042","ACCIDENT_DT":"01/12/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"LEFT FLOOR CATCHES UNDER CRABLINE WHEN BARGE IS BEING SET IN PLACE TO LOAD. THE BARGE SHIFTS BECAUSE OF BOAT GOING UP RIVER CAUSING THE CABLE TO SNAP. HE RECEIVES BRUISES TO THE TOP OR HIS LEF T FOOT.","sourceDate":"2001-01-12"},{"SOURCE_ROW_NUMBER":"89658","DOCUMENT_NO":"220002410083","ACCIDENT_DT":"08/14/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"44","NARRATIVE":"WHILE GAUGING BARGE BEING LOADED WITH COAL THE CABLE WHICH PULLS BARGE UP AND DOWN THE RIVER HIT EE'S LEFT ELBOW. CREATED A BRUISE AND SMALL CUT.","sourceDate":"2000-08-14"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-06-30","lastDate":"2026-06-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":28,"firstDate":"2001-02-28","lastDate":"2013-01-03","metrics":{"ss":13,"delinquent":28,"recentRows":0,"paidPenalty":3629,"proposedPenalty":4334,"currentAssessment":4334},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1841789","VIOLATION_NO":"7166885","ISSUE_DT":"01/03/2013","CFR_STANDARD_CD":"48.27(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"1841788","VIOLATION_NO":"7166884","ISSUE_DT":"01/03/2013","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"1830450","VIOLATION_NO":"8112424","ISSUE_DT":"06/06/2012","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"687.00","CURRENT_ASSESSMENT_AMT":"687.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"1820200","VIOLATION_NO":"8146398","ISSUE_DT":"12/27/2011","CFR_STANDARD_CD":"77.410(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"1820199","VIOLATION_NO":"8146397","ISSUE_DT":"12/27/2011","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"1804321","VIOLATION_NO":"8124501","ISSUE_DT":"03/30/2011","CFR_STANDARD_CD":"77.904","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"1804320","VIOLATION_NO":"8124500","ISSUE_DT":"03/30/2011","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"1804319","VIOLATION_NO":"8124499","ISSUE_DT":"03/30/2011","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"1809371","VIOLATION_NO":"8099356","ISSUE_DT":"12/11/2010","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-12-11"},{"SOURCE_ROW_NUMBER":"866361","VIOLATION_NO":"6612919","ISSUE_DT":"11/14/2008","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-14"},{"SOURCE_ROW_NUMBER":"866360","VIOLATION_NO":"6612918","ISSUE_DT":"11/14/2008","CFR_STANDARD_CD":"77.1109(e)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-14"},{"SOURCE_ROW_NUMBER":"866359","VIOLATION_NO":"6612917","ISSUE_DT":"11/14/2008","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-14"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3,"firstDate":"2003-11-14","lastDate":"2003-11-14","metrics":{"appeals":0,"decisions":3,"recentRows":0,"decisionPenalty":0,"originalPenalty":451},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"482207","VIOLATION_NO":"7216893","DOCKET_NO":"WEVA 2003-239","DECISION_DT":"11/14/2003","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2003-11-14"},{"SOURCE_ROW_NUMBER":"482206","VIOLATION_NO":"7216889","DOCKET_NO":"WEVA 2003-239","DECISION_DT":"11/14/2003","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"226.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2003-11-14"},{"SOURCE_ROW_NUMBER":"179806","VIOLATION_NO":"7216891","DOCKET_NO":"WEVA 2003-239","DECISION_DT":"11/14/2003","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"153.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2003-11-14"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":45,"firstDate":"2000-09-27","lastDate":"2013-01-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":44,"maxConcentration":0.351,"concentrationTotal":4.657},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1571547","CASS_NUM":"57970393","SMP_TAKEN_DT":"1/3/2013","CONC":".045","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"386366","CASS_NUM":"57970240","SMP_TAKEN_DT":"1/3/2013","CONC":".086","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"304061","CASS_NUM":"57970408","SMP_TAKEN_DT":"1/3/2013","CONC":".087","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"279699","CASS_NUM":"57966956","SMP_TAKEN_DT":"6/6/2012","CONC":".038","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"153474","CASS_NUM":"57967011","SMP_TAKEN_DT":"6/6/2012","CONC":".092","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WATER TRUCK OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"587308","CASS_NUM":"57884783","SMP_TAKEN_DT":"3/30/2011","CONC":".05","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"350637","CASS_NUM":"57884790","SMP_TAKEN_DT":"3/30/2011","CONC":".058","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"1219278","CASS_NUM":"57903934","SMP_TAKEN_DT":"12/11/2010","CONC":".064","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-12-11"},{"SOURCE_ROW_NUMBER":"739331","CASS_NUM":"57903945","SMP_TAKEN_DT":"12/11/2010","CONC":".102","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-12-11"},{"SOURCE_ROW_NUMBER":"1592709","CASS_NUM":"57837493","SMP_TAKEN_DT":"9/9/2010","CONC":".083","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-09"},{"SOURCE_ROW_NUMBER":"1098541","CASS_NUM":"57837514","SMP_TAKEN_DT":"9/9/2010","CONC":".044","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TIPPLE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-09"},{"SOURCE_ROW_NUMBER":"524683","CASS_NUM":"57837532","SMP_TAKEN_DT":"9/9/2010","CONC":".046","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-09"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":503,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":125,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1988-05-01","lastDate":"1988-05-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":61,"firstDate":"2000-01-27","lastDate":"2026-06-30","metrics":{"inspectors":69,"recentRows":12,"onSiteHours":325,"inspectionHours":621.75,"inspectionSamples":36},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"649455","EVENT_NO":"F00F872","INSPECTION_BEGIN_DT":"06/30/2026","INSPECTION_END_DT":"06/30/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.75","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2026-06-30"},{"SOURCE_ROW_NUMBER":"856049","EVENT_NO":"6322100","INSPECTION_BEGIN_DT":"03/17/2026","INSPECTION_END_DT":"03/17/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.75","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2026-03-17"},{"SOURCE_ROW_NUMBER":"775762","EVENT_NO":"6321994","INSPECTION_BEGIN_DT":"09/08/2025","INSPECTION_END_DT":"09/08/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2025-09-08"},{"SOURCE_ROW_NUMBER":"203211","EVENT_NO":"6322310","INSPECTION_BEGIN_DT":"01/07/2025","INSPECTION_END_DT":"01/07/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2025-01-07"},{"SOURCE_ROW_NUMBER":"760131","EVENT_NO":"6321969","INSPECTION_BEGIN_DT":"09/13/2024","INSPECTION_END_DT":"09/13/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2024-09-13"},{"SOURCE_ROW_NUMBER":"978872","EVENT_NO":"6289544","INSPECTION_BEGIN_DT":"12/04/2023","INSPECTION_END_DT":"12/04/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2023-12-04"},{"SOURCE_ROW_NUMBER":"767989","EVENT_NO":"6289541","INSPECTION_BEGIN_DT":"07/26/2023","INSPECTION_END_DT":"07/26/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.75","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2023-07-26"},{"SOURCE_ROW_NUMBER":"765246","EVENT_NO":"6302630","INSPECTION_BEGIN_DT":"02/21/2023","INSPECTION_END_DT":"02/22/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2023-02-21"},{"SOURCE_ROW_NUMBER":"130259","EVENT_NO":"6317293","INSPECTION_BEGIN_DT":"06/14/2022","INSPECTION_END_DT":"06/14/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2022-06-14"},{"SOURCE_ROW_NUMBER":"7235","EVENT_NO":"6318020","INSPECTION_BEGIN_DT":"12/09/2021","INSPECTION_END_DT":"12/09/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2021-12-09"},{"SOURCE_ROW_NUMBER":"1119332","EVENT_NO":"6316085","INSPECTION_BEGIN_DT":"05/06/2021","INSPECTION_END_DT":"05/06/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2021-05-06"},{"SOURCE_ROW_NUMBER":"618700","EVENT_NO":"6317508","INSPECTION_BEGIN_DT":"01/04/2021","INSPECTION_END_DT":"01/04/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2021-01-04"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":96,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2025-Q4":{"hours":0,"employees":0,"production":0},"2025-Q3":{"hours":0,"employees":0,"production":0},"2025-Q2":{"hours":0,"employees":0,"production":0},"2025-Q1":{"hours":0,"employees":0,"production":0},"2024-Q3":{"hours":0,"employees":0,"production":0},"2023-Q4":{"hours":0,"employees":0,"production":0},"2023-Q3":{"hours":0,"employees":0,"production":0},"2023-Q1":{"hours":0,"employees":0,"production":0},"2022-Q4":{"hours":0,"employees":0,"production":0},"2022-Q3":{"hours":0,"employees":0,"production":0},"2022-Q2":{"hours":0,"employees":0,"production":0},"2022-Q1":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003":{"hours":9967,"employees":13,"production":0},"2004":{"hours":7928,"employees":4,"production":0},"2005":{"hours":7644,"employees":3,"production":0},"2006":{"hours":9389,"employees":3,"production":0},"2007":{"hours":6619,"employees":3,"production":0},"2008":{"hours":6409,"employees":3,"production":0},"2009":{"hours":4003,"employees":2,"production":0},"2010":{"hours":5571,"employees":4,"production":0},"2011":{"hours":3537,"employees":3,"production":0},"2012":{"hours":1977,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":20,"firstDate":"2000-02-01","lastDate":"2013-01-03","metrics":{"recentRows":0,"doseOver100":6,"actDoseTotal":1622,"pelDoseTotal":1324},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"232939","EVENT_NO":"6298059","SURVEY_DATE":"01/03/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"15","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"232938","EVENT_NO":"6298059","SURVEY_DATE":"01/03/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"46","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"232937","EVENT_NO":"6298059","SURVEY_DATE":"01/03/2013","OCCUPATION_CD_DESC":"OUTSIDE FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"36","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"232936","EVENT_NO":"6295869","SURVEY_DATE":"06/06/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"19","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"232935","EVENT_NO":"6295869","SURVEY_DATE":"06/06/2012","OCCUPATION_CD_DESC":"WATER TRUCK OPERATOR","MACHINE_CD":"39","MANUFACTURER_CD":"041","ACT_DOSE_85":"11","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"232934","EVENT_NO":"6291432","SURVEY_DATE":"12/11/2010","OCCUPATION_CD_DESC":"OUTSIDE FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"35","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2010-12-11"},{"SOURCE_ROW_NUMBER":"232933","EVENT_NO":"6291432","SURVEY_DATE":"12/11/2010","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"12","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2010-12-11"},{"SOURCE_ROW_NUMBER":"232932","EVENT_NO":"6286472","SURVEY_DATE":"03/22/2010","OCCUPATION_CD_DESC":"SAFETY REPRESENTATIVE","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"38","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2010-03-22"},{"SOURCE_ROW_NUMBER":"232931","EVENT_NO":"6286472","SURVEY_DATE":"03/22/2010","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"125","PEL_DOSE_90":"111","SURVEY_TYPE":"I","sourceDate":"2010-03-22"},{"SOURCE_ROW_NUMBER":"232930","EVENT_NO":"6286472","SURVEY_DATE":"03/22/2010","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"128","PEL_DOSE_90":"116","SURVEY_TYPE":"I","sourceDate":"2010-03-22"},{"SOURCE_ROW_NUMBER":"232929","EVENT_NO":"6286472","SURVEY_DATE":"03/22/2010","OCCUPATION_CD_DESC":"YARD ENGINE OPERATOR","MACHINE_CD":"25","MANUFACTURER_CD":"025","ACT_DOSE_85":"48","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2010-03-22"},{"SOURCE_ROW_NUMBER":"232928","EVENT_NO":"4122459","SURVEY_DATE":"11/14/2008","OCCUPATION_CD_DESC":"MOTORMAN/LOCOMOTIVE OPERATOR","MACHINE_CD":"25","MANUFACTURER_CD":"045","ACT_DOSE_85":"99","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2008-11-14"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":28,"firstDate":"2001-02-28","lastDate":"2013-01-03","metrics":{"ss":13,"amountDue":4334,"contested":0,"amountPaid":3629,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":4334},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2684484","VIOLATION_NO":"7166885","VIOLATION_ISSUE_DT":"01/03/2013","SIG_SUB":"N","PART_SECTION":"48.27(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/03/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"2684483","VIOLATION_NO":"7166884","VIOLATION_ISSUE_DT":"01/03/2013","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"2684474","VIOLATION_NO":"8112424","VIOLATION_ISSUE_DT":"06/06/2012","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/06/2012","PROPOSED_PENALTY":"687","AMOUNT_DUE":"687","AMOUNT_PAID":"687","CONTESTED_IND":"N","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"2684489","VIOLATION_NO":"8146398","VIOLATION_ISSUE_DT":"12/27/2011","SIG_SUB":"N","PART_SECTION":"77.410(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/28/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"2684488","VIOLATION_NO":"8146397","VIOLATION_ISSUE_DT":"12/27/2011","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/28/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"2684465","VIOLATION_NO":"8124501","VIOLATION_ISSUE_DT":"03/30/2011","SIG_SUB":"Y","PART_SECTION":"77.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/30/2011","PROPOSED_PENALTY":"127","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"N","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"2684464","VIOLATION_NO":"8124500","VIOLATION_ISSUE_DT":"03/30/2011","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/30/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"2684463","VIOLATION_NO":"8124499","VIOLATION_ISSUE_DT":"03/30/2011","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/30/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-03-30"},{"SOURCE_ROW_NUMBER":"2684487","VIOLATION_NO":"8099356","VIOLATION_ISSUE_DT":"12/11/2010","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/20/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-12-11"},{"SOURCE_ROW_NUMBER":"2684482","VIOLATION_NO":"6612919","VIOLATION_ISSUE_DT":"11/14/2008","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/14/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-14"},{"SOURCE_ROW_NUMBER":"2684481","VIOLATION_NO":"6612918","VIOLATION_ISSUE_DT":"11/14/2008","SIG_SUB":"N","PART_SECTION":"77.1109(e)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/14/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-14"},{"SOURCE_ROW_NUMBER":"2684480","VIOLATION_NO":"6612917","VIOLATION_ISSUE_DT":"11/14/2008","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/14/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-14"}]}],"safety":{"href":"/api/v1/mines/4607509/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4607509/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Training of miners assigned to a task in which they have had no previous experience; minimum courses of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.27","part":"48","subchapter":"H","subpart":"B","id":"48.27","citation":"30 CFR 48.27","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":2},{"chapter":"I","heading":"Identification of circuit breakers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.904","part":"77","subchapter":"O","subpart":"J","id":"77.904","citation":"30 CFR 77.904","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4607509","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}