{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4606213","name":"Mine No 4","status":"Abandoned","status_date":"2016-06-09","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Webster","nearest_town":"Birch River","operator_id":"0051081","operator_name":"Brooks Run Mining Company LLC","controller_id":"0137121","controller_name":"Pristine Clean Energy LLC","district":"C04","office":"Summersville WV Field Office","employees":0,"latitude":38.580833,"longitude":-80.595},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":565},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4606213","name":"Mine No 4"},"operator":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"controller":{"type":"controller","id":"0137121","name":"Pristine Clean Energy LLC"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"1979-09-27","validTo":"1992-02-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|C01767|1979-09-27|1992-02-27"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01883","name":"El Paso Energy Corp"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"1979-10-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|C01883|1979-10-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P18174","name":"Oneida Coal Company Inc"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"1980-08-01","validTo":"1992-02-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|P18174|1980-08-01|1992-02-27"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"operator","id":"P18174","name":"Oneida Coal Company Inc"},"validFrom":"1980-08-01","validTo":"1992-02-27","current":false,"derived":true,"evidenceMineId":"4606213","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|P18174|1980-08-01|C01767|1979-09-27|55831"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21861","name":"Oneida Coal Company Inc"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"1992-02-28","validTo":"1995-12-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|P21861|1992-02-28|1995-12-14"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"1992-02-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|C13408|1992-02-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"P21861","name":"Oneida Coal Company Inc"},"validFrom":"1992-02-28","validTo":"1995-12-14","current":false,"derived":true,"evidenceMineId":"4606213","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|P21861|1992-02-28|C13408|1992-02-28|89539"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24023","name":"Coastal Coal-West Virginia, LLC"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"1995-12-15","validTo":"2003-02-27","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|P24023|1995-12-15|2003-02-27"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01883","name":"El Paso Energy Corp"},"object":{"type":"operator","id":"P24023","name":"Coastal Coal-West Virginia, LLC"},"validFrom":"1995-12-15","validTo":"2003-02-27","current":false,"derived":true,"evidenceMineId":"4606213","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|P24023|1995-12-15|C01883|1979-10-01|56582"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"2003-02-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|0041211|2003-02-01|2016-07-25"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"2003-02-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|0051081|2003-02-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"validFrom":"2003-02-28","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4606213","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|0051081|2003-02-28|0041211|2003-02-01|1654"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"2016-07-26","validTo":"2017-10-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|0127923|2016-07-26|2017-10-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"validFrom":"2016-07-26","validTo":"2017-10-04","current":false,"derived":true,"evidenceMineId":"4606213","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|0051081|2003-02-28|0127923|2016-07-26|25072"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0137121","name":"Pristine Clean Energy LLC"},"object":{"type":"mine","id":"4606213","name":"Mine No 4"},"validFrom":"2017-10-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|0137121|2017-10-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0137121","name":"Pristine Clean Energy LLC"},"object":{"type":"operator","id":"0051081","name":"Brooks Run Mining Company LLC"},"validFrom":"2017-10-05","validTo":null,"current":true,"derived":true,"evidenceMineId":"4606213","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4606213|0051081|2003-02-28|0137121|2017-10-05|27621"}}],"coverage":{"historyRecords":6,"edgeCount":16,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":7,"firstDate":"2014-05-30","lastDate":"2015-10-29","metrics":{"daysLost":87,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":16,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"266041","DOCUMENT_NO":"220153130002","ACCIDENT_DT":"10/29/2015","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","NARRATIVE":"The operator has been notified that the employee has been diagnosed with occupational pneumoconiosis.","sourceDate":"2015-10-29"},{"SOURCE_ROW_NUMBER":"154189","DOCUMENT_NO":"220153060004","ACCIDENT_DT":"10/22/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee slipped on miner cable and sustained a strain to the right knee.","sourceDate":"2015-10-22"},{"SOURCE_ROW_NUMBER":"231657","DOCUMENT_NO":"220152940001","ACCIDENT_DT":"10/08/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"An employee received a fracture to the right wrist while driving a 2 man personnel carrier over the mine track system.","sourceDate":"2015-10-08"},{"SOURCE_ROW_NUMBER":"38150","DOCUMENT_NO":"220152800019","ACCIDENT_DT":"10/05/2015","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"19","NARRATIVE":"TRUCK RAN INTO DITCH AND FLIPPED OVER.","sourceDate":"2015-10-05"},{"SOURCE_ROW_NUMBER":"210124","DOCUMENT_NO":"220152310002","ACCIDENT_DT":"08/05/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"Injured was backing scoop around the corner to reposition scoop, when the corner rolled & a piece of rock fell in the deck of the scoop striking his right arm at the elbow resulting in a bruise.","sourceDate":"2015-08-05"},{"SOURCE_ROW_NUMBER":"63738","DOCUMENT_NO":"220152110002","ACCIDENT_DT":"07/27/2015","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall was discovered at approximately 8:40 AM between spad 75637 and 75663 in the number 1 entry (left return). Dimensions of the fall were 120' long x 18' wide x 6' high. The area was bolted with 6' fully grouted bolts. Location of the fall was 1,600' outby the section dumping point.","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"63737","DOCUMENT_NO":"220141550025","ACCIDENT_DT":"05/30/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"Employee was walking in the #1 entry toward the #4 west seal when he stepped on some uneven bottom and sprained his left ankle.","sourceDate":"2014-05-30"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2016-06-09","lastDate":"2016-06-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":56,"firstDate":"2013-07-08","lastDate":"2016-04-25","metrics":{"ss":10,"delinquent":55,"recentRows":0,"paidPenalty":9421,"proposedPenalty":10146,"currentAssessment":10048},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1890204","VIOLATION_NO":"9060531","ISSUE_DT":"04/25/2016","CFR_STANDARD_CD":"77.410(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-04-25"},{"SOURCE_ROW_NUMBER":"1881730","VIOLATION_NO":"9057583","ISSUE_DT":"12/08/2015","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"946.00","CURRENT_ASSESSMENT_AMT":"946.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-08"},{"SOURCE_ROW_NUMBER":"1881729","VIOLATION_NO":"9057582","ISSUE_DT":"12/08/2015","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-12-08"},{"SOURCE_ROW_NUMBER":"1859454","VIOLATION_NO":"8156700","ISSUE_DT":"08/20/2015","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-20"},{"SOURCE_ROW_NUMBER":"1859453","VIOLATION_NO":"8156699","ISSUE_DT":"08/10/2015","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"828.00","CURRENT_ASSESSMENT_AMT":"828.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-10"},{"SOURCE_ROW_NUMBER":"1859452","VIOLATION_NO":"8156698","ISSUE_DT":"08/04/2015","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"1859451","VIOLATION_NO":"8156697","ISSUE_DT":"08/04/2015","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"1859450","VIOLATION_NO":"8156696","ISSUE_DT":"08/04/2015","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"1859449","VIOLATION_NO":"8156695","ISSUE_DT":"08/03/2015","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-03"},{"SOURCE_ROW_NUMBER":"1859448","VIOLATION_NO":"8156694","ISSUE_DT":"07/20/2015","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-20"},{"SOURCE_ROW_NUMBER":"1881537","VIOLATION_NO":"9006411","ISSUE_DT":"05/27/2015","CFR_STANDARD_CD":"75.1107-4(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-05-27"},{"SOURCE_ROW_NUMBER":"1859446","VIOLATION_NO":"9006901","ISSUE_DT":"05/27/2015","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-05-27"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2015-06-11","lastDate":"2015-06-11","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":305,"originalPenalty":403},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"111912","VIOLATION_NO":"9006361","DOCKET_NO":"WEVA 2015-0161","DECISION_DT":"06/11/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"403.00","DECISION_PENALTY_AMT":"305.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-06-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":184,"firstDate":"2014-08-26","lastDate":"2016-07-20","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":23,"validSamples":161,"maxConcentration":3.167,"concentrationTotal":88.165},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1125521","CASS_NUM":"51384475","SMP_TAKEN_DT":"7/20/2016","CONC":".746","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER VOID","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-07-20"},{"SOURCE_ROW_NUMBER":"873773","CASS_NUM":"58160533","SMP_TAKEN_DT":"11/12/2015","CONC":".629","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-12"},{"SOURCE_ROW_NUMBER":"541050","CASS_NUM":"58160550","SMP_TAKEN_DT":"11/12/2015","CONC":".52","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-12"},{"SOURCE_ROW_NUMBER":"313376","CASS_NUM":"58160493","SMP_TAKEN_DT":"11/12/2015","CONC":".569","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-12"},{"SOURCE_ROW_NUMBER":"193269","CASS_NUM":"58160521","SMP_TAKEN_DT":"11/12/2015","CONC":".085","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-12"},{"SOURCE_ROW_NUMBER":"115530","CASS_NUM":"58160304","SMP_TAKEN_DT":"11/12/2015","CONC":".049","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-12"},{"SOURCE_ROW_NUMBER":"96324","CASS_NUM":"58160552","SMP_TAKEN_DT":"11/12/2015","CONC":".401","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-12"},{"SOURCE_ROW_NUMBER":"1639817","CASS_NUM":"58160348","SMP_TAKEN_DT":"11/10/2015","CONC":".246","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-10"},{"SOURCE_ROW_NUMBER":"1633243","CASS_NUM":"58160532","SMP_TAKEN_DT":"11/10/2015","CONC":".472","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-10"},{"SOURCE_ROW_NUMBER":"1603809","CASS_NUM":"58160551","SMP_TAKEN_DT":"11/10/2015","CONC":".461","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-10"},{"SOURCE_ROW_NUMBER":"1598755","CASS_NUM":"58160344","SMP_TAKEN_DT":"11/10/2015","CONC":".367","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-10"},{"SOURCE_ROW_NUMBER":"1587394","CASS_NUM":"58160437","SMP_TAKEN_DT":"11/10/2015","CONC":".233","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-10"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2014-08-28","lastDate":"2014-08-28","metrics":{"decisions":1,"ssChanged":0,"recentRows":0,"decisionPenalty":305,"proposedPenalty":403},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"315972","CITATION_NO":"9006361","CITATION_ISSUE_DT":"08/28/2014","DOCKET_NO":"WEVA 2015-0161","DECISION_DT":"06/11/2015","CFR_STANDARD_CODE":"48.26","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"403.00","DECISION_PENALTY_AMT":"305.00","sourceDate":"2014-08-28"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":111,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":31,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"1980-08-01","lastDate":"2003-02-28","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":23,"firstDate":"2013-07-08","lastDate":"2016-04-25","metrics":{"inspectors":74,"recentRows":0,"onSiteHours":1132.5,"inspectionHours":2080,"inspectionSamples":274},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"880386","EVENT_NO":"6311310","INSPECTION_BEGIN_DT":"04/25/2016","INSPECTION_END_DT":"06/09/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2016-04-25"},{"SOURCE_ROW_NUMBER":"4914","EVENT_NO":"6295550","INSPECTION_BEGIN_DT":"01/27/2016","INSPECTION_END_DT":"03/02/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"94","SUM_TOTAL_ON_SITE_HOURS":"34.75","sourceDate":"2016-01-27"},{"SOURCE_ROW_NUMBER":"484960","EVENT_NO":"6303388","INSPECTION_BEGIN_DT":"01/04/2016","INSPECTION_END_DT":"01/04/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2016-01-04"},{"SOURCE_ROW_NUMBER":"352912","EVENT_NO":"6308864","INSPECTION_BEGIN_DT":"11/09/2015","INSPECTION_END_DT":"12/15/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"145","SUM_TOTAL_ON_SITE_HOURS":"78.5","sourceDate":"2015-11-09"},{"SOURCE_ROW_NUMBER":"29287","EVENT_NO":"6309362","INSPECTION_BEGIN_DT":"10/07/2015","INSPECTION_END_DT":"10/07/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2015-10-07"},{"SOURCE_ROW_NUMBER":"930460","EVENT_NO":"6302085","INSPECTION_BEGIN_DT":"07/01/2015","INSPECTION_END_DT":"09/01/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"251","SUM_TOTAL_ON_SITE_HOURS":"156","sourceDate":"2015-07-01"},{"SOURCE_ROW_NUMBER":"329048","EVENT_NO":"6308809","INSPECTION_BEGIN_DT":"05/27/2015","INSPECTION_END_DT":"05/27/2015","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2015-05-27"},{"SOURCE_ROW_NUMBER":"530284","EVENT_NO":"6302081","INSPECTION_BEGIN_DT":"04/02/2015","INSPECTION_END_DT":"06/03/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"290.25","SUM_TOTAL_ON_SITE_HOURS":"179.25","sourceDate":"2015-04-02"},{"SOURCE_ROW_NUMBER":"624745","EVENT_NO":"6309352","INSPECTION_BEGIN_DT":"01/02/2015","INSPECTION_END_DT":"03/26/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"280","SUM_TOTAL_ON_SITE_HOURS":"141","sourceDate":"2015-01-02"},{"SOURCE_ROW_NUMBER":"95167","EVENT_NO":"6296300","INSPECTION_BEGIN_DT":"10/02/2014","INSPECTION_END_DT":"12/15/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"302.5","SUM_TOTAL_ON_SITE_HOURS":"165.5","sourceDate":"2014-10-02"},{"SOURCE_ROW_NUMBER":"557615","EVENT_NO":"6303357","INSPECTION_BEGIN_DT":"09/16/2014","INSPECTION_END_DT":"09/16/2014","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"838129","EVENT_NO":"6295447","INSPECTION_BEGIN_DT":"07/09/2014","INSPECTION_END_DT":"09/12/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"246","SUM_TOTAL_ON_SITE_HOURS":"146.25","sourceDate":"2014-07-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":41,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q2":{"hours":0,"employees":0,"production":0},"2017-Q1":{"hours":0,"employees":0,"production":0},"2016-Q4":{"hours":0,"employees":0,"production":0},"2016-Q3":{"hours":0,"employees":0,"production":0},"2016-Q2":{"hours":0,"employees":0,"production":0},"2016-Q1":{"hours":2489,"employees":5,"production":0},"2015-Q4":{"hours":18999,"employees":40,"production":25033},"2015-Q3":{"hours":31535,"employees":58,"production":53446},"2015-Q2":{"hours":32534,"employees":57,"production":56294},"2015-Q1":{"hours":31859,"employees":56,"production":49259},"2014-Q4":{"hours":27005,"employees":55,"production":39065},"2014-Q3":{"hours":22167,"employees":37,"production":29283}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014":{"hours":68286,"employees":31,"production":68348},"2015":{"hours":114927,"employees":53,"production":184032},"2016":{"hours":2489,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":26,"firstDate":"2014-08-27","lastDate":"2015-08-13","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":1288,"pelDoseTotal":870},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"229652","EVENT_NO":"6302085","SURVEY_DATE":"08/13/2015","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"7","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2015-08-13"},{"SOURCE_ROW_NUMBER":"229651","EVENT_NO":"6302085","SURVEY_DATE":"08/13/2015","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"9","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2015-08-13"},{"SOURCE_ROW_NUMBER":"229657","EVENT_NO":"6302085","SURVEY_DATE":"08/04/2015","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"142","PEL_DOSE_90":"126","SURVEY_TYPE":"I","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"229656","EVENT_NO":"6302085","SURVEY_DATE":"08/04/2015","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"68","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"229655","EVENT_NO":"6302085","SURVEY_DATE":"08/04/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"229654","EVENT_NO":"6302085","SURVEY_DATE":"08/04/2015","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"54","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"229653","EVENT_NO":"6302085","SURVEY_DATE":"08/04/2015","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"68","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"229650","EVENT_NO":"6296300","SURVEY_DATE":"11/13/2014","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"29","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"229649","EVENT_NO":"6296300","SURVEY_DATE":"11/13/2014","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"40","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"229648","EVENT_NO":"6296300","SURVEY_DATE":"11/13/2014","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"14","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"229647","EVENT_NO":"6296300","SURVEY_DATE":"11/13/2014","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"37","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"229646","EVENT_NO":"6296300","SURVEY_DATE":"11/04/2014","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"33","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2014-11-04"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":13,"firstDate":"2014-09-04","lastDate":"2015-11-12","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":10.7,"validSamples":12,"quartzPctTotal":85.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"53359","CASSETTE_NO":"58160493","SAMPLE_DT":"11/12/2015","QUARTZ_PCT":"08.3","QUARTZ_MICROGRAMS":"47","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-12"},{"SOURCE_ROW_NUMBER":"37769","CASSETTE_NO":"58160523","SAMPLE_DT":"11/10/2015","QUARTZ_PCT":"09.3","QUARTZ_MICROGRAMS":"13","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-11-10"},{"SOURCE_ROW_NUMBER":"85220","CASSETTE_NO":"58160325","SAMPLE_DT":"09/01/2015","QUARTZ_PCT":"02.3","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-09-01"},{"SOURCE_ROW_NUMBER":"35806","CASSETTE_NO":"58160317","SAMPLE_DT":"08/20/2015","QUARTZ_PCT":"08.5","QUARTZ_MICROGRAMS":"37","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-20"},{"SOURCE_ROW_NUMBER":"27552","CASSETTE_NO":"58160261","SAMPLE_DT":"08/20/2015","QUARTZ_PCT":"07.6","QUARTZ_MICROGRAMS":"28","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-20"},{"SOURCE_ROW_NUMBER":"6951","CASSETTE_NO":"58159142","SAMPLE_DT":"05/04/2015","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"QUARTZ LABORATORY VOID","sourceDate":"2015-05-04"},{"SOURCE_ROW_NUMBER":"68812","CASSETTE_NO":"58159037","SAMPLE_DT":"04/29/2015","QUARTZ_PCT":"06.9","QUARTZ_MICROGRAMS":"40","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-04-29"},{"SOURCE_ROW_NUMBER":"120171","CASSETTE_NO":"58136055","SAMPLE_DT":"02/10/2015","QUARTZ_PCT":"06.8","QUARTZ_MICROGRAMS":"56","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-02-10"},{"SOURCE_ROW_NUMBER":"68302","CASSETTE_NO":"58135703","SAMPLE_DT":"11/13/2014","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"34","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"34006","CASSETTE_NO":"58135962","SAMPLE_DT":"11/06/2014","QUARTZ_PCT":"06.6","QUARTZ_MICROGRAMS":"53","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-06"},{"SOURCE_ROW_NUMBER":"62752","CASSETTE_NO":"58135828","SAMPLE_DT":"10/23/2014","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-10-23"},{"SOURCE_ROW_NUMBER":"90208","CASSETTE_NO":"58135760","SAMPLE_DT":"10/20/2014","QUARTZ_PCT":"06.3","QUARTZ_MICROGRAMS":"29","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-10-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":56,"firstDate":"2013-07-08","lastDate":"2016-04-25","metrics":{"ss":10,"amountDue":10048,"contested":0,"amountPaid":9421,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":10146},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2656426","VIOLATION_NO":"9060531","VIOLATION_ISSUE_DT":"04/25/2016","SIG_SUB":"N","PART_SECTION":"77.410(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/26/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-04-25"},{"SOURCE_ROW_NUMBER":"2656463","VIOLATION_NO":"9057583","VIOLATION_ISSUE_DT":"12/08/2015","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/08/2015","PROPOSED_PENALTY":"946","AMOUNT_DUE":"946","AMOUNT_PAID":"946","CONTESTED_IND":"N","sourceDate":"2015-12-08"},{"SOURCE_ROW_NUMBER":"2656462","VIOLATION_NO":"9057582","VIOLATION_ISSUE_DT":"12/08/2015","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/08/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-12-08"},{"SOURCE_ROW_NUMBER":"2656436","VIOLATION_NO":"8156700","VIOLATION_ISSUE_DT":"08/20/2015","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/25/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-08-20"},{"SOURCE_ROW_NUMBER":"2656435","VIOLATION_NO":"8156699","VIOLATION_ISSUE_DT":"08/10/2015","SIG_SUB":"N","SECTION_OF_ACT":"316(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"16","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/13/2015","PROPOSED_PENALTY":"828","AMOUNT_DUE":"828","AMOUNT_PAID":"828","CONTESTED_IND":"N","sourceDate":"2015-08-10"},{"SOURCE_ROW_NUMBER":"2656434","VIOLATION_NO":"8156698","VIOLATION_ISSUE_DT":"08/04/2015","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/04/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"2656433","VIOLATION_NO":"8156697","VIOLATION_ISSUE_DT":"08/04/2015","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/04/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"2656432","VIOLATION_NO":"8156696","VIOLATION_ISSUE_DT":"08/04/2015","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/04/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"2656431","VIOLATION_NO":"8156695","VIOLATION_ISSUE_DT":"08/03/2015","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-08-03"},{"SOURCE_ROW_NUMBER":"2656430","VIOLATION_NO":"8156694","VIOLATION_ISSUE_DT":"07/20/2015","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2015","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"190","CONTESTED_IND":"N","sourceDate":"2015-07-20"},{"SOURCE_ROW_NUMBER":"2656427","VIOLATION_NO":"9006411","VIOLATION_ISSUE_DT":"05/27/2015","SIG_SUB":"N","PART_SECTION":"75.1107-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/27/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-05-27"},{"SOURCE_ROW_NUMBER":"2656424","VIOLATION_NO":"9006901","VIOLATION_ISSUE_DT":"05/27/2015","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/27/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-05-27"}]}],"safety":{"href":"/api/v1/mines/4606213/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4606213/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4606213","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}