{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4602143","name":"Robin Hood No 9","status":"Abandoned and Sealed","status_date":"2000-12-06","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Boone","nearest_town":"Prenter","operator_id":"P24179","operator_name":"Pine Ridge Coal Company","controller_id":"0071611","controller_name":"Patriot Coal Corporation","district":"C04","office":"Madison WV Field Office","employees":0,"latitude":37.9239,"longitude":-81.605},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":143},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"operator":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company"},"controller":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P02313","name":"Armco Inc"},"object":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"validFrom":"1950-01-01","validTo":"1984-02-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|P02313|1950-01-01|1984-02-26"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01978","name":"Armco Inc"},"object":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|C01978|1950-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01978","name":"Armco Inc"},"object":{"type":"operator","id":"P02313","name":"Armco Inc"},"validFrom":"1950-01-01","validTo":"1984-02-26","current":false,"derived":true,"evidenceMineId":"4602143","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|P02313|1950-01-01|C01978|1950-01-01|57002"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22944","name":"Pine Ridge Coal Company"},"object":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"validFrom":"1984-02-27","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|P22944|1984-02-27|1998-05-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"validFrom":"1984-02-27","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|C05313|1984-02-27|1998-05-18"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"operator","id":"P22944","name":"Pine Ridge Coal Company"},"validFrom":"1984-02-27","validTo":"1998-05-18","current":false,"derived":true,"evidenceMineId":"4602143","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|P22944|1984-02-27|C05313|1984-02-27|68327"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company"},"object":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"validFrom":"1998-05-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|P24179|1998-05-19|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"validFrom":"1998-05-19","validTo":"2007-10-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|C15833|1998-05-19|2007-10-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company"},"validFrom":"1998-05-19","validTo":"2007-10-30","current":false,"derived":true,"evidenceMineId":"4602143","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|P24179|1998-05-19|C15833|1998-05-19|96982"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"mine","id":"4602143","name":"Robin Hood No 9"},"validFrom":"2007-10-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|0071611|2007-10-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"P24179","name":"Pine Ridge Coal Company"},"validFrom":"2007-10-31","validTo":null,"current":true,"derived":true,"evidenceMineId":"4602143","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4602143|P24179|1998-05-19|0071611|2007-10-31|10284"}}],"coverage":{"historyRecords":4,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":16,"firstDate":"2000-01-03","lastDate":"2000-08-31","metrics":{"daysLost":142,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"67992","DOCUMENT_NO":"220002560057","ACCIDENT_DT":"08/31/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"43","NARRATIVE":"EMPLOYEE WAS CHANGING A CELL IN SCOOP BATTERY. WHILE USING THE OVERHEAD CRANE TO LIFT CELL, THEAUGER USED TO LIFT THE CELL BROKE AND A PIECE OFTHE AUGER HOOKED TO THE CRANE HIT HIS RIGHT HAND","sourceDate":"2000-08-31"},{"SOURCE_ROW_NUMBER":"231586","DOCUMENT_NO":"220002070013","ACCIDENT_DT":"07/19/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Truck driver","NO_INJURIES":"1","DAYS_LOST":"33","NARRATIVE":"DRIVER WAS TIGHTENING LUG NUTS ON TRUCK UNIT #3011 WITH A 3/4 DRIVE WHEEL RATCHET. THE RATCHETS LOCKING MECHANISIM BROKE CAUSING IT TO FREE WHEEL. THE DRIVER WAS APPLYING PRESSURE ON THE RATCH ET WHE THIS OCCURRED. DRIVER STATED THAT HE FELLDOWN CAUSING AN INJURY TO HIS BACK.","sourceDate":"2000-07-19"},{"SOURCE_ROW_NUMBER":"119557","DOCUMENT_NO":"220001920065","ACCIDENT_DT":"06/29/2000","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"ALLEGED HEARING LOSS.","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"102320","DOCUMENT_NO":"220001520009","ACCIDENT_DT":"05/10/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"66","NARRATIVE":"ON 5/11/00 EMPLOYEE STATED THAT HE THOUGHT THAT HE HAD INJURED HIS SHOULDER THE DAY BEFORE WHEN HE WAS PULLING MINER CABLE OUT OF THE ROADWAY. RECEIVED CONFIRMATION OF ACTUAL INJURY 5/22/00.","sourceDate":"2000-05-10"},{"SOURCE_ROW_NUMBER":"110892","DOCUMENT_NO":"220001220122","ACCIDENT_DT":"04/03/2000","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"ALL OTHER OCCUPATIONAL ILLNESSES","ACCIDENT_TYPE":"NEC","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","NARRATIVE":"MEDICAL INFORMATION (X-RAYS) INDICATES THAT THE EMPLOYEE SUFFERS FROM OSTEOPHYTOSIS AND SPONDYLOSIS OF THE CERVICAL SPINE.","sourceDate":"2000-04-03"},{"SOURCE_ROW_NUMBER":"16453","DOCUMENT_NO":"220001160001","ACCIDENT_DT":"03/16/2000","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","NARRATIVE":"DEGENERATIVE CHANGES TO THE SPINE STENOSIS AT L4-L5. EMPLOYEE STATED THAT HE WAS HANGING A MOBIL ROOF SUPPORT CABLE AND FELT PAIN IN HIS LOWER BACK. NOTE: RECEIVED MEDICAL INFORMATION ON 4- 12-00.","sourceDate":"2000-03-16"},{"SOURCE_ROW_NUMBER":"192773","DOCUMENT_NO":"220000830011","ACCIDENT_DT":"03/14/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNPLANNED ROOF FALL OCCURRED IN THE #8 ENTRY OF A SECTION 800' FROM THE FACE, ONE BREAK OUTBYSPAD 5576 THE FALL MEASURED 45' LONG 20' WIDE AND 6 1/2' HIGH. THIS WAS A CONTINUATION OF AN OLD FALL.","sourceDate":"2000-03-14"},{"SOURCE_ROW_NUMBER":"123730","DOCUMENT_NO":"220000810014","ACCIDENT_DT":"03/10/2000","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","NARRATIVE":"ALLEGED OCCUPATIONAL PNEUMOCONIOSIS, RECEIVED NOTIFICATION 3-10-00.","sourceDate":"2000-03-10"},{"SOURCE_ROW_NUMBER":"119556","DOCUMENT_NO":"220000700043","ACCIDENT_DT":"03/02/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FIRE","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FIRE WAS DETECTED AT AN OPENING ALONG THE OUTCROP OF THE INACTIVE (SEALED) AREA OF THE MINE. THE FIRE WAS APPARENTLY THE RESULT OF A FOREST FIRE THAT CAUGHT THE COAL SEAM ON FIRE.","sourceDate":"2000-03-02"},{"SOURCE_ROW_NUMBER":"154123","DOCUMENT_NO":"220000670043","ACCIDENT_DT":"02/25/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNPLANNED ROOF FALL OCCURRED IN THE #4 ENTRY. 4 BRKS INBY SURY STATION 5614 - 900' OUTBY THE SECTION. THE FALL MEASURED 40'LONG, 18'WIDE, AND 6'HIGH.","sourceDate":"2000-02-25"},{"SOURCE_ROW_NUMBER":"85253","DOCUMENT_NO":"220000600023","ACCIDENT_DT":"02/14/2000","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"UNKNOWN HEARING LOSS.","sourceDate":"2000-02-14"},{"SOURCE_ROW_NUMBER":"240242","DOCUMENT_NO":"220000530109","ACCIDENT_DT":"02/10/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNPLANNED ROOF FALL WAS FOUND ON THE H3 ROADWAY 2 BRK ACROSS FROM SURVEY STATION 5439 OUT BY SECTION. THE FALL MEASURED 40' LONG 10' WIDE 6' HIGH.","sourceDate":"2000-02-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2000-12-06","lastDate":"2000-12-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":15,"firstDate":"2000-02-24","lastDate":"2000-11-15","metrics":{"ss":3,"delinquent":15,"recentRows":0,"paidPenalty":1206,"proposedPenalty":1206,"currentAssessment":1206},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"760042","VIOLATION_NO":"7194305","ISSUE_DT":"11/15/2000","CFR_STANDARD_CD":"75.364(a)(2)(iii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-15"},{"SOURCE_ROW_NUMBER":"760047","VIOLATION_NO":"7194304","ISSUE_DT":"11/13/2000","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"760046","VIOLATION_NO":"7194303","ISSUE_DT":"11/13/2000","CFR_STANDARD_CD":"75.900-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"760045","VIOLATION_NO":"7194302","ISSUE_DT":"11/13/2000","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"760044","VIOLATION_NO":"7194301","ISSUE_DT":"11/13/2000","CFR_STANDARD_CD":"77.800-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"760043","VIOLATION_NO":"7194288","ISSUE_DT":"10/02/2000","CFR_STANDARD_CD":"75.364(a)(2)(iii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-10-02"},{"SOURCE_ROW_NUMBER":"756152","VIOLATION_NO":"4404309","ISSUE_DT":"04/26/2000","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-04-26"},{"SOURCE_ROW_NUMBER":"756151","VIOLATION_NO":"4404308","ISSUE_DT":"04/26/2000","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-04-26"},{"SOURCE_ROW_NUMBER":"756150","VIOLATION_NO":"4404307","ISSUE_DT":"04/26/2000","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-04-26"},{"SOURCE_ROW_NUMBER":"756154","VIOLATION_NO":"7183075","ISSUE_DT":"04/19/2000","CFR_STANDARD_CD":"75.352","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-04-19"},{"SOURCE_ROW_NUMBER":"756153","VIOLATION_NO":"7183074","ISSUE_DT":"04/19/2000","CFR_STANDARD_CD":"75.364(b)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"161.00","CURRENT_ASSESSMENT_AMT":"161.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-04-19"},{"SOURCE_ROW_NUMBER":"755307","VIOLATION_NO":"7174548","ISSUE_DT":"02/29/2000","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-02-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":41,"firstDate":"2000-01-17","lastDate":"2000-08-08","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":40,"maxConcentration":4.049,"concentrationTotal":34.578},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1128734","CASS_NUM":"57278545","SMP_TAKEN_DT":"8/8/2000","CONC":"1.323","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"1070863","CASS_NUM":"57278543","SMP_TAKEN_DT":"8/8/2000","CONC":".433","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"915610","CASS_NUM":"57278541","SMP_TAKEN_DT":"8/8/2000","CONC":"2.271","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"506162","CASS_NUM":"57278516","SMP_TAKEN_DT":"8/8/2000","CONC":".486","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"314172","CASS_NUM":"57278534","SMP_TAKEN_DT":"8/8/2000","CONC":".392","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"250060","CASS_NUM":"57278512","SMP_TAKEN_DT":"8/8/2000","CONC":".223","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"1490991","CASS_NUM":"57265724","SMP_TAKEN_DT":"6/29/2000","CONC":".431","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"847895","CASS_NUM":"57265864","SMP_TAKEN_DT":"6/29/2000","CONC":"1.121","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"613165","CASS_NUM":"57265858","SMP_TAKEN_DT":"6/29/2000","CONC":".282","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"539600","CASS_NUM":"57265718","SMP_TAKEN_DT":"6/29/2000","CONC":".394","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"450911","CASS_NUM":"57265855","SMP_TAKEN_DT":"6/29/2000","CONC":".201","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"346896","CASS_NUM":"57265741","SMP_TAKEN_DT":"6/29/2000","CONC":".773","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-06-29"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1950-01-01","lastDate":"1998-05-19","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":12,"firstDate":"2000-01-06","lastDate":"2000-09-29","metrics":{"inspectors":15,"recentRows":0,"onSiteHours":292.5,"inspectionHours":501,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"553970","EVENT_NO":"4089766","INSPECTION_BEGIN_DT":"09/29/2000","INSPECTION_END_DT":"12/08/2000","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2000-09-29"},{"SOURCE_ROW_NUMBER":"283547","EVENT_NO":"4089765","INSPECTION_BEGIN_DT":"09/29/2000","INSPECTION_END_DT":"12/08/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2000-09-29"},{"SOURCE_ROW_NUMBER":"981826","EVENT_NO":"4089600","INSPECTION_BEGIN_DT":"07/31/2000","INSPECTION_END_DT":"07/31/2000","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2000-07-31"},{"SOURCE_ROW_NUMBER":"1069141","EVENT_NO":"4087977","INSPECTION_BEGIN_DT":"06/29/2000","INSPECTION_END_DT":"08/21/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"94","SUM_TOTAL_ON_SITE_HOURS":"56.5","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"54424","EVENT_NO":"4087972","INSPECTION_BEGIN_DT":"04/05/2000","INSPECTION_END_DT":"06/13/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"144.5","SUM_TOTAL_ON_SITE_HOURS":"74.5","sourceDate":"2000-04-05"},{"SOURCE_ROW_NUMBER":"585620","EVENT_NO":"4088074","INSPECTION_BEGIN_DT":"03/20/2000","INSPECTION_END_DT":"03/21/2000","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2000-03-20"},{"SOURCE_ROW_NUMBER":"133157","EVENT_NO":"4087968","INSPECTION_BEGIN_DT":"03/09/2000","INSPECTION_END_DT":"03/09/2000","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2000-03-09"},{"SOURCE_ROW_NUMBER":"624673","EVENT_NO":"4088070","INSPECTION_BEGIN_DT":"03/03/2000","INSPECTION_END_DT":"03/06/2000","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2000-03-03"},{"SOURCE_ROW_NUMBER":"1021536","EVENT_NO":"4087537","INSPECTION_BEGIN_DT":"02/28/2000","INSPECTION_END_DT":"03/01/2000","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2000-02-28"},{"SOURCE_ROW_NUMBER":"441080","EVENT_NO":"4087526","INSPECTION_BEGIN_DT":"01/20/2000","INSPECTION_END_DT":"01/20/2000","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2000-01-20"},{"SOURCE_ROW_NUMBER":"1124505","EVENT_NO":"4087960","INSPECTION_BEGIN_DT":"01/06/2000","INSPECTION_END_DT":"03/10/2000","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2000-01-06"},{"SOURCE_ROW_NUMBER":"689282","EVENT_NO":"4087959","INSPECTION_BEGIN_DT":"01/06/2000","INSPECTION_END_DT":"03/10/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"131.5","SUM_TOTAL_ON_SITE_HOURS":"79","sourceDate":"2000-01-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000-Q4":{"hours":0,"employees":0,"production":0},"2000-Q3":{"hours":14090,"employees":40,"production":57700},"2000-Q2":{"hours":27622,"employees":57,"production":181600},"2000-Q1":{"hours":30822,"employees":57,"production":204300}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":72534,"employees":52,"production":443600}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":4,"firstDate":"2000-03-09","lastDate":"2000-03-09","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":403,"pelDoseTotal":349},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"221699","EVENT_NO":"4087968","SURVEY_DATE":"03/09/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"53","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2000-03-09"},{"SOURCE_ROW_NUMBER":"221698","EVENT_NO":"4087968","SURVEY_DATE":"03/09/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"236","PEL_DOSE_90":"227","SURVEY_TYPE":"I","sourceDate":"2000-03-09"},{"SOURCE_ROW_NUMBER":"221697","EVENT_NO":"4087968","SURVEY_DATE":"03/09/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"97","PEL_DOSE_90":"88","SURVEY_TYPE":"I","sourceDate":"2000-03-09"},{"SOURCE_ROW_NUMBER":"221696","EVENT_NO":"4087968","SURVEY_DATE":"03/09/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"17","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2000-03-09"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":5,"firstDate":"2000-02-10","lastDate":"2000-08-08","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":13,"validSamples":5,"quartzPctTotal":37.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"101711","CASSETTE_NO":"57278541","SAMPLE_DT":"08/08/2000","QUARTZ_PCT":"07.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"71717","CASSETTE_NO":"57278543","SAMPLE_DT":"08/08/2000","QUARTZ_PCT":"13.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"90889","CASSETTE_NO":"57265864","SAMPLE_DT":"06/29/2000","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-06-29"},{"SOURCE_ROW_NUMBER":"31390","CASSETTE_NO":"57253063","SAMPLE_DT":"04/24/2000","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-04-24"},{"SOURCE_ROW_NUMBER":"77086","CASSETTE_NO":"57245106","SAMPLE_DT":"02/10/2000","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-02-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":15,"firstDate":"2000-02-24","lastDate":"2000-11-15","metrics":{"ss":3,"amountDue":1206,"contested":0,"amountPaid":1206,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":1206},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2591964","VIOLATION_NO":"7194305","VIOLATION_ISSUE_DT":"11/15/2000","SIG_SUB":"N","PART_SECTION":"75.364(a)(2)(iii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-15"},{"SOURCE_ROW_NUMBER":"2591963","VIOLATION_NO":"7194304","VIOLATION_ISSUE_DT":"11/13/2000","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/14/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"2591962","VIOLATION_NO":"7194303","VIOLATION_ISSUE_DT":"11/13/2000","SIG_SUB":"N","PART_SECTION":"75.900-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/14/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"2591961","VIOLATION_NO":"7194302","VIOLATION_ISSUE_DT":"11/13/2000","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/14/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"2591960","VIOLATION_NO":"7194301","VIOLATION_ISSUE_DT":"11/13/2000","SIG_SUB":"N","PART_SECTION":"77.800-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/14/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"2591959","VIOLATION_NO":"7194288","VIOLATION_ISSUE_DT":"10/02/2000","SIG_SUB":"N","PART_SECTION":"75.364(a)(2)(iii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/02/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-10-02"},{"SOURCE_ROW_NUMBER":"2591956","VIOLATION_NO":"4404309","VIOLATION_ISSUE_DT":"04/26/2000","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/03/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-04-26"},{"SOURCE_ROW_NUMBER":"2591955","VIOLATION_NO":"4404308","VIOLATION_ISSUE_DT":"04/26/2000","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/03/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-04-26"},{"SOURCE_ROW_NUMBER":"2591954","VIOLATION_NO":"4404307","VIOLATION_ISSUE_DT":"04/26/2000","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/03/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-04-26"},{"SOURCE_ROW_NUMBER":"2591958","VIOLATION_NO":"7183075","VIOLATION_ISSUE_DT":"04/19/2000","SIG_SUB":"N","PART_SECTION":"75.352","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/25/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-04-19"},{"SOURCE_ROW_NUMBER":"2591957","VIOLATION_NO":"7183074","VIOLATION_ISSUE_DT":"04/19/2000","SIG_SUB":"Y","PART_SECTION":"75.364(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/25/2000","PROPOSED_PENALTY":"161","AMOUNT_DUE":"161","AMOUNT_PAID":"161","CONTESTED_IND":"N","sourceDate":"2000-04-19"},{"SOURCE_ROW_NUMBER":"2591953","VIOLATION_NO":"7174548","VIOLATION_ISSUE_DT":"02/29/2000","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/01/2000","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"N","sourceDate":"2000-02-29"}]}],"safety":{"href":"/api/v1/mines/4602143/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4602143/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.900-3","part":"75","subchapter":"O","subpart":"J","id":"75.900-3","citation":"30 CFR 75.900-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-I/section-77.800-1","part":"77","subchapter":"O","subpart":"I","id":"77.800-1","citation":"30 CFR 77.800-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3},{"chapter":"I","heading":"Actions in response to AMS malfunction, alert, or alarm signals.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.352","part":"75","subchapter":"O","subpart":"D","id":"75.352","citation":"30 CFR 75.352","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4602143","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}