{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4601456","name":"Federal No 2","status":"Abandoned","status_date":"2021-01-13","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Monongalia","nearest_town":"Fairview","operator_id":"0157293","operator_name":"Phoenix Federal No 2 Mining, LLC.","controller_id":"C12016","controller_name":"John F  Hale Jr","district":"C03","office":"Morgantown WV Field Office","employees":0,"latitude":39.667778,"longitude":-80.252778},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":39014},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4601456","name":"Federal No 2"},"operator":{"type":"operator","id":"0157293","name":"Phoenix Federal No 2 Mining, LLC."},"controller":{"type":"controller","id":"C12016","name":"John F  Hale Jr"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01037","name":"Eastern Associated Coal Corp"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"1950-01-01","validTo":"1987-05-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|P01037|1950-01-01|1987-05-14"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00880","name":"Eastern Gas & Fuel Association"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|C00880|1950-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00880","name":"Eastern Gas & Fuel Association"},"object":{"type":"operator","id":"P01037","name":"Eastern Associated Coal Corp"},"validFrom":"1950-01-01","validTo":"1987-05-14","current":false,"derived":true,"evidenceMineId":"4601456","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|P01037|1950-01-01|C00880|1950-01-01|50757"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"1987-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|C05313|1987-04-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P18547","name":"Eastern Associated Coal Corp"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"1987-05-15","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|P18547|1987-05-15|1998-05-18"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"operator","id":"P18547","name":"Eastern Associated Coal Corp"},"validFrom":"1987-05-15","validTo":"1998-05-18","current":false,"derived":true,"evidenceMineId":"4601456","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|P18547|1987-05-15|C05313|1987-04-01|68318"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"1998-03-26","validTo":"2007-10-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|C15833|1998-03-26|2007-10-30"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"1998-05-19","validTo":"2015-10-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|P24184|1998-05-19|2015-10-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"validFrom":"1998-05-19","validTo":"2007-10-30","current":false,"derived":true,"evidenceMineId":"4601456","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|P24184|1998-05-19|C15833|1998-03-26|96907"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"2007-10-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|0071611|2007-10-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0071611","name":"Patriot Coal Corporation"},"object":{"type":"operator","id":"P24184","name":"Eastern Associated Coal LLC"},"validFrom":"2007-10-31","validTo":"2015-10-25","current":false,"derived":true,"evidenceMineId":"4601456","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|P24184|1998-05-19|0071611|2007-10-31|10283"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0141834","name":"ERP Federal Mining Complex, LLC."},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"2015-10-26","validTo":"2018-06-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|0141834|2015-10-26|2018-06-06"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0121101","name":"Virginia Conservation Legacy Fund (VCLF)"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"2015-10-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|0121101|2015-10-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0121101","name":"Virginia Conservation Legacy Fund (VCLF)"},"object":{"type":"operator","id":"0141834","name":"ERP Federal Mining Complex, LLC."},"validFrom":"2015-10-26","validTo":"2018-06-06","current":false,"derived":true,"evidenceMineId":"4601456","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|0141834|2015-10-26|0121101|2015-10-26|23580"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0157293","name":"Phoenix Federal No 2 Mining, LLC."},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"2018-06-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|0157293|2018-06-07|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12016","name":"John F  Hale Jr"},"object":{"type":"mine","id":"4601456","name":"Federal No 2"},"validFrom":"2018-06-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|C12016|2018-06-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12016","name":"John F  Hale Jr"},"object":{"type":"operator","id":"0157293","name":"Phoenix Federal No 2 Mining, LLC."},"validFrom":"2018-06-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"4601456","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601456|0157293|2018-06-07|C12016|2018-06-07|85916"}}],"coverage":{"historyRecords":6,"edgeCount":17,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":846,"firstDate":"2000-01-03","lastDate":"2020-02-27","metrics":{"daysLost":34094,"injuries":753,"fatalities":1,"recentRows":0,"restrictedDays":174,"contractorRecords":47},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"106465","DOCUMENT_NO":"220200900015","ACCIDENT_DT":"02/27/2020","DEGREE_INJURY":"FATALITY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"While spotting the trailer, the victim stepped in front of the wheel of the trailer. The driver started to pull forward, catching the victim under the wheel, running over victim up to about the chest area by the time they got driver to stop. The victim later died at the hospital as a result of the injuries.","sourceDate":"2020-02-27"},{"SOURCE_ROW_NUMBER":"16434","DOCUMENT_NO":"220173130024","ACCIDENT_DT":"11/03/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee claims to have strained left shoulder while pulling rock dust hose through a mandoor.  EE completed shift and asked to complete an incident report as a precaution.  Employee called off work on Monday, November 6, 2017 citing the \"injury\".","sourceDate":"2017-11-03"},{"SOURCE_ROW_NUMBER":"175602","DOCUMENT_NO":"220173130012","ACCIDENT_DT":"10/24/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"Employee claims to have strained right hand while shoveling on the 1 East Belt.  EE continued to work regular shifts.  On 10/30/17, ee requested supervisor to document the incident of 10/24/17 as hand continued to hurt.  EE started missing work on 10/31/17.","sourceDate":"2017-10-24"},{"SOURCE_ROW_NUMBER":"50796","DOCUMENT_NO":"220173130007","ACCIDENT_DT":"10/24/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Utility man, Shift tech, Service/Dump truck operator","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"Employee claims to have strained employee's lower back while shoveling spillage on the first floor of the prep plant. Employee continued to work and then called off on 11/06/2017 citing the earlier \"injury\".","sourceDate":"2017-10-24"},{"SOURCE_ROW_NUMBER":"171338","DOCUMENT_NO":"220172980016","ACCIDENT_DT":"10/18/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"16","NARRATIVE":"Employee claims that back spasms started when employee bent down to pick up a roof bolter cable plug.  Employee was transported to a local hospital, examined, and released. Has not returned to work since.","sourceDate":"2017-10-18"},{"SOURCE_ROW_NUMBER":"50795","DOCUMENT_NO":"220172980068","ACCIDENT_DT":"10/16/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee bumped EE's back on some belt structure.","sourceDate":"2017-10-16"},{"SOURCE_ROW_NUMBER":"102281","DOCUMENT_NO":"220172890024","ACCIDENT_DT":"10/12/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"Employee was riding out of the mine on a section portal bus.  As the bus traveled through a switch, the bus was jarred from side to side.  The jarring motion allegedly caused a sprain/strain to the employee's lower left back.  Employee completed shift and went to a doctor later that day.  Employee has not returned to work.","sourceDate":"2017-10-12"},{"SOURCE_ROW_NUMBER":"158398","DOCUMENT_NO":"220172890017","ACCIDENT_DT":"10/11/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"Employee was stacking cement blocks on a pallet when ee felt back give out and ee dropped a block on upper left thigh.  Employee was transported to a local hospital where all tests were negative and ee was released.  Employee has not returned to work.","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"59338","DOCUMENT_NO":"220172770025","ACCIDENT_DT":"09/28/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"Employee was along the track when a bus inby ee was entering a spur.  The bus snagged the lifeline, stretching it tight, and breaking it.  The lifeline snapped back toward employee and a directional cone hit ee on the cap light.  Employee continued working but started feeling tingling in face and decided to seek medical aid.  EE was transported to a local hospital.","sourceDate":"2017-09-28"},{"SOURCE_ROW_NUMBER":"102280","DOCUMENT_NO":"220172700022","ACCIDENT_DT":"09/25/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"LW Propman, Propman helper, Move crew if LW, Move-up man, Jacksetter, Advanceman LW helper","NO_INJURIES":"1","DAYS_LOST":"32","NARRATIVE":"Employee was attempting to lower shield # 118.  The shield failed to function from adjacent controls.  Employee used the in-shield control to lower the shield.  When EE did this, the shield unexpectedly moved forward and shoved EE to the mine pavement.","sourceDate":"2017-09-25"},{"SOURCE_ROW_NUMBER":"33691","DOCUMENT_NO":"220172610017","ACCIDENT_DT":"09/13/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"42","NARRATIVE":"Employee used their foot to attempt to throw a switch. They slipped and fell backward onto their SCSR unit. This caused pain to their lower back.  Transported to local hospital. Negative x-rays, etc. Released to return to work but did not report in on the next scheduled shift.","sourceDate":"2017-09-13"},{"SOURCE_ROW_NUMBER":"257359","DOCUMENT_NO":"220172480013","ACCIDENT_DT":"08/26/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"Employee states that employee felt a \"pain\" in employee's right arm while carrying cement blocks to build a stopping (wall).  Employee completed employee's shift, but then called off on employee's next scheduled shift.","sourceDate":"2017-08-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2021-01-13","lastDate":"2021-01-13","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":7633,"firstDate":"2000-01-10","lastDate":"2020-08-17","metrics":{"ss":1890,"delinquent":7194,"recentRows":0,"paidPenalty":2888287.63,"proposedPenalty":6926880,"currentAssessment":5208580.65},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2820035","VIOLATION_NO":"9182156","ISSUE_DT":"08/17/2020","CFR_STANDARD_CD":"77.216-4(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"206.00","CURRENT_ASSESSMENT_AMT":"206.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-08-17"},{"SOURCE_ROW_NUMBER":"2820034","VIOLATION_NO":"9182153","ISSUE_DT":"07/30/2020","CFR_STANDARD_CD":"77.216-3(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"206.00","CURRENT_ASSESSMENT_AMT":"206.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-07-30"},{"SOURCE_ROW_NUMBER":"2820033","VIOLATION_NO":"9182151","ISSUE_DT":"07/30/2020","CFR_STANDARD_CD":"77.216-3(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"206.00","CURRENT_ASSESSMENT_AMT":"206.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-07-30"},{"SOURCE_ROW_NUMBER":"1758672","VIOLATION_NO":"9187411","ISSUE_DT":"05/11/2020","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"1758671","VIOLATION_NO":"9187410","ISSUE_DT":"05/11/2020","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"135.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"1758669","VIOLATION_NO":"9187409","ISSUE_DT":"05/11/2020","CFR_STANDARD_CD":"77.1607(g)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1483.00","CURRENT_ASSESSMENT_AMT":"1483.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"1758665","VIOLATION_NO":"9182152","ISSUE_DT":"05/11/2020","CFR_STANDARD_CD":"50.10(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"6159.00","CURRENT_ASSESSMENT_AMT":"6159.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"1758664","VIOLATION_NO":"9182150","ISSUE_DT":"05/11/2020","CFR_STANDARD_CD":"77.1607(u)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"1758663","VIOLATION_NO":"9182149","ISSUE_DT":"05/11/2020","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1738.00","CURRENT_ASSESSMENT_AMT":"1738.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"1758670","VIOLATION_NO":"9182148","ISSUE_DT":"03/20/2020","CFR_STANDARD_CD":"50.20(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-03-20"},{"SOURCE_ROW_NUMBER":"1758552","VIOLATION_NO":"9250088","ISSUE_DT":"02/24/2020","CFR_STANDARD_CD":"77.1607(p)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2020-02-24"},{"SOURCE_ROW_NUMBER":"1758619","VIOLATION_NO":"9186889","ISSUE_DT":"11/18/2019","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-11-18"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1947,"firstDate":"2001-02-12","lastDate":"2019-07-31","metrics":{"appeals":0,"decisions":1947,"recentRows":0,"decisionPenalty":3753911.15,"originalPenalty":5522928},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"412421","VIOLATION_NO":"9182268","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2019-07-31"},{"SOURCE_ROW_NUMBER":"411091","VIOLATION_NO":"9182272","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"301.00","DECISION_PENALTY_AMT":"301.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2019-07-31"},{"SOURCE_ROW_NUMBER":"138744","VIOLATION_NO":"9182271","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2019-07-31"},{"SOURCE_ROW_NUMBER":"138390","VIOLATION_NO":"9182269","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2019-07-31"},{"SOURCE_ROW_NUMBER":"127072","VIOLATION_NO":"9090663","DOCKET_NO":"WEVA 2017-0318","DECISION_DT":"05/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7075.00","DECISION_PENALTY_AMT":"7075.00","JUDGE_FIRST_NAME":"Jerold","JUDGE_LAST_NAME":"Feldman","sourceDate":"2018-05-23"},{"SOURCE_ROW_NUMBER":"395249","VIOLATION_NO":"9128974","DOCKET_NO":"WEVA 2017-0478","DECISION_DT":"04/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"14170.00","DECISION_PENALTY_AMT":"14170.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-04-23"},{"SOURCE_ROW_NUMBER":"395248","VIOLATION_NO":"9125510","DOCKET_NO":"WEVA 2017-0478","DECISION_DT":"04/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2250.00","DECISION_PENALTY_AMT":"2250.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-04-23"},{"SOURCE_ROW_NUMBER":"128818","VIOLATION_NO":"9128977","DOCKET_NO":"WEVA 2017-0478","DECISION_DT":"04/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8094.00","DECISION_PENALTY_AMT":"8094.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-04-23"},{"SOURCE_ROW_NUMBER":"128452","VIOLATION_NO":"9129022","DOCKET_NO":"WEVA 2017-0478","DECISION_DT":"04/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8094.00","DECISION_PENALTY_AMT":"8094.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-04-23"},{"SOURCE_ROW_NUMBER":"128357","VIOLATION_NO":"9129073","DOCKET_NO":"WEVA 2017-0478","DECISION_DT":"04/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3098.00","DECISION_PENALTY_AMT":"3098.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-04-23"},{"SOURCE_ROW_NUMBER":"396198","VIOLATION_NO":"9129075","DOCKET_NO":"WEVA 2017-0520","DECISION_DT":"03/26/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1770.00","DECISION_PENALTY_AMT":"1770.00","JUDGE_FIRST_NAME":"L.Zane","JUDGE_LAST_NAME":"Gill","sourceDate":"2018-03-26"},{"SOURCE_ROW_NUMBER":"396197","VIOLATION_NO":"9125439","DOCKET_NO":"WEVA 2017-0520","DECISION_DT":"03/26/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1392.00","DECISION_PENALTY_AMT":"1392.00","JUDGE_FIRST_NAME":"L.Zane","JUDGE_LAST_NAME":"Gill","sourceDate":"2018-03-26"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":6111,"firstDate":"2000-01-18","lastDate":"2017-11-08","metrics":{"recentRows":0,"cpdmSamples":606,"voidSamples":1802,"validSamples":4309,"maxConcentration":149.477,"concentrationTotal":4186.469},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2958458","SMP_TAKEN_DT":"11/8/2017","CONC":".067","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-08"},{"SOURCE_ROW_NUMBER":"2958457","SMP_TAKEN_DT":"11/8/2017","CONC":".342","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-08"},{"SOURCE_ROW_NUMBER":"2789275","SMP_TAKEN_DT":"11/7/2017","CONC":".316","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-07"},{"SOURCE_ROW_NUMBER":"2618591","SMP_TAKEN_DT":"11/7/2017","CONC":".243","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-07"},{"SOURCE_ROW_NUMBER":"2789225","SMP_TAKEN_DT":"11/6/2017","CONC":".159","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-06"},{"SOURCE_ROW_NUMBER":"2021483","SMP_TAKEN_DT":"11/6/2017","CONC":".127","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-06"},{"SOURCE_ROW_NUMBER":"2701911","SMP_TAKEN_DT":"10/26/2017","CONC":".058","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-26"},{"SOURCE_ROW_NUMBER":"1678904","SMP_TAKEN_DT":"10/26/2017","CONC":".269","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-26"},{"SOURCE_ROW_NUMBER":"2787166","SMP_TAKEN_DT":"10/25/2017","CONC":".221","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-25"},{"SOURCE_ROW_NUMBER":"2360719","SMP_TAKEN_DT":"10/25/2017","CONC":".11","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-25"},{"SOURCE_ROW_NUMBER":"2361370","SMP_TAKEN_DT":"10/24/2017","CONC":".22","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-24"},{"SOURCE_ROW_NUMBER":"2190678","SMP_TAKEN_DT":"10/24/2017","CONC":".258","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MULTIPLE SAMPLES SAME SHIFT","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-24"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1972,"firstDate":"2000-02-24","lastDate":"2020-06-18","metrics":{"linkedIssuances":1972},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1827,"firstDate":"2003-07-08","lastDate":"2019-01-17","metrics":{"decisions":1827,"ssChanged":476,"recentRows":0,"decisionPenalty":3719498.65,"proposedPenalty":5495197},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"387503","CITATION_NO":"9182268","CITATION_ISSUE_DT":"01/17/2019","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","CFR_STANDARD_CODE":"48.23(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2019-01-17"},{"SOURCE_ROW_NUMBER":"384989","CITATION_NO":"9182271","CITATION_ISSUE_DT":"01/17/2019","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","CFR_STANDARD_CODE":"48.26(b)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2019-01-17"},{"SOURCE_ROW_NUMBER":"328220","CITATION_NO":"9182272","CITATION_ISSUE_DT":"01/17/2019","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","CFR_STANDARD_CODE":"48.26(b)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"301.00","DECISION_PENALTY_AMT":"301.00","sourceDate":"2019-01-17"},{"SOURCE_ROW_NUMBER":"103037","CITATION_NO":"9182269","CITATION_ISSUE_DT":"01/17/2019","DOCKET_NO":"WEVA 2019-0328","DECISION_DT":"07/31/2019","CFR_STANDARD_CODE":"77.107-1","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2019-01-17"},{"SOURCE_ROW_NUMBER":"326444","CITATION_NO":"9129464","CITATION_ISSUE_DT":"09/06/2017","DOCKET_NO":"WEVA 2018-0065","DECISION_DT":"03/02/2018","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1967.00","DECISION_PENALTY_AMT":"1967.00","sourceDate":"2017-09-06"},{"SOURCE_ROW_NUMBER":"440524","CITATION_NO":"9129355","CITATION_ISSUE_DT":"08/15/2017","DOCKET_NO":"WEVA 2018-0067","DECISION_DT":"03/02/2018","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1770.00","DECISION_PENALTY_AMT":"1770.00","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"211007","CITATION_NO":"9090829","CITATION_ISSUE_DT":"08/08/2017","DOCKET_NO":"WEVA 2018-0067","DECISION_DT":"03/02/2018","CFR_STANDARD_CODE":"75.342(a)(4)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"934.00","DECISION_PENALTY_AMT":"934.00","sourceDate":"2017-08-08"},{"SOURCE_ROW_NUMBER":"272094","CITATION_NO":"9129239","CITATION_ISSUE_DT":"07/25/2017","DOCKET_NO":"WEVA 2018-0121","DECISION_DT":"03/06/2018","CFR_STANDARD_CODE":"75.364(b)(8)(i)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"48000.00","DECISION_PENALTY_AMT":"48000.00","sourceDate":"2017-07-25"},{"SOURCE_ROW_NUMBER":"213628","CITATION_NO":"9129238","CITATION_ISSUE_DT":"07/25/2017","DOCKET_NO":"WEVA 2018-0121","DECISION_DT":"03/06/2018","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"69400.00","DECISION_PENALTY_AMT":"69400.00","sourceDate":"2017-07-25"},{"SOURCE_ROW_NUMBER":"437605","CITATION_NO":"9129235","CITATION_ISSUE_DT":"07/20/2017","DOCKET_NO":"WEVA 2018-0121","DECISION_DT":"03/06/2018","CFR_STANDARD_CODE":"75.364(b)(8)(i)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"11400.00","DECISION_PENALTY_AMT":"11400.00","sourceDate":"2017-07-20"},{"SOURCE_ROW_NUMBER":"385409","CITATION_NO":"9125594","CITATION_ISSUE_DT":"07/20/2017","DOCKET_NO":"WEVA 2018-0066","DECISION_DT":"02/16/2018","CFR_STANDARD_CODE":"77.205(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4627.00","DECISION_PENALTY_AMT":"4627.00","sourceDate":"2017-07-20"},{"SOURCE_ROW_NUMBER":"270141","CITATION_NO":"9125589","CITATION_ISSUE_DT":"07/20/2017","DOCKET_NO":"WEVA 2018-0066","DECISION_DT":"02/16/2018","CFR_STANDARD_CODE":"77.216-3(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"4627.00","DECISION_PENALTY_AMT":"4627.00","sourceDate":"2017-07-20"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":6392,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":32,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":1236,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":32,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"1950-01-01","lastDate":"2018-06-07","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":2136,"firstDate":"2000-01-03","lastDate":"2021-06-30","metrics":{"inspectors":3294,"recentRows":2,"onSiteHours":56001.25,"inspectionHours":83287.5,"inspectionSamples":3580},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1063213","EVENT_NO":"7025061","INSPECTION_BEGIN_DT":"06/30/2021","INSPECTION_END_DT":"06/30/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2021-06-30"},{"SOURCE_ROW_NUMBER":"710636","EVENT_NO":"7013227","INSPECTION_BEGIN_DT":"06/23/2021","INSPECTION_END_DT":"06/23/2021","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2021-06-23"},{"SOURCE_ROW_NUMBER":"558335","EVENT_NO":"7012888","INSPECTION_BEGIN_DT":"12/16/2020","INSPECTION_END_DT":"12/16/2020","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2020-12-16"},{"SOURCE_ROW_NUMBER":"521358","EVENT_NO":"7012905","INSPECTION_BEGIN_DT":"12/15/2020","INSPECTION_END_DT":"12/15/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2020-12-15"},{"SOURCE_ROW_NUMBER":"131445","EVENT_NO":"6274655","INSPECTION_BEGIN_DT":"09/30/2020","INSPECTION_END_DT":"09/30/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2020-09-30"},{"SOURCE_ROW_NUMBER":"478628","EVENT_NO":"7012744","INSPECTION_BEGIN_DT":"08/17/2020","INSPECTION_END_DT":"08/17/2020","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2020-08-17"},{"SOURCE_ROW_NUMBER":"669710","EVENT_NO":"7012742","INSPECTION_BEGIN_DT":"07/29/2020","INSPECTION_END_DT":"07/30/2020","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2020-07-29"},{"SOURCE_ROW_NUMBER":"407869","EVENT_NO":"6279873","INSPECTION_BEGIN_DT":"05/11/2020","INSPECTION_END_DT":"05/11/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"206421","EVENT_NO":"6279815","INSPECTION_BEGIN_DT":"05/11/2020","INSPECTION_END_DT":"05/12/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"154083","EVENT_NO":"6279811","INSPECTION_BEGIN_DT":"04/14/2020","INSPECTION_END_DT":"04/14/2020","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2020-04-14"},{"SOURCE_ROW_NUMBER":"695918","EVENT_NO":"6274507","INSPECTION_BEGIN_DT":"03/18/2020","INSPECTION_END_DT":"03/27/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2020-03-18"},{"SOURCE_ROW_NUMBER":"386934","EVENT_NO":"6279868","INSPECTION_BEGIN_DT":"03/18/2020","INSPECTION_END_DT":"05/12/2020","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2020-03-18"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":299,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2020-Q1":{"hours":80,"employees":1,"production":0},"2019-Q4":{"hours":2774,"employees":8,"production":0},"2019-Q3":{"hours":3729,"employees":10,"production":0},"2019-Q2":{"hours":5921,"employees":15,"production":0},"2019-Q1":{"hours":12606,"employees":27,"production":0},"2018-Q1":{"hours":7964,"employees":13,"production":0},"2017-Q4":{"hours":80320,"employees":142,"production":64900},"2017-Q3":{"hours":157431,"employees":285,"production":210769},"2017-Q2":{"hours":174330,"employees":287,"production":378426},"2017-Q1":{"hours":178039,"employees":305,"production":449487},"2016-Q4":{"hours":166685,"employees":291,"production":304398},"2016-Q3":{"hours":148028,"employees":272,"production":336130}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":77,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":1264731,"employees":560,"production":3744764},"2012":{"hours":1280784,"employees":568,"production":4044937},"2013":{"hours":1147376,"employees":517,"production":3363090},"2014":{"hours":1094469,"employees":488,"production":2866980},"2015":{"hours":1023651,"employees":456,"production":2441623},"2016":{"hours":673352,"employees":312,"production":1507373},"2017":{"hours":590120,"employees":255,"production":1103582},"2018":{"hours":7964,"employees":13,"production":0},"2019":{"hours":25030,"employees":22,"production":0},"2020":{"hours":80,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":605,"firstDate":"2000-01-06","lastDate":"2017-05-18","metrics":{"recentRows":0,"doseOver100":161,"actDoseTotal":51670,"pelDoseTotal":33734},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"220012","EVENT_NO":"6274051","SURVEY_DATE":"05/18/2017","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"13","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2017-05-18"},{"SOURCE_ROW_NUMBER":"220011","EVENT_NO":"6274051","SURVEY_DATE":"05/18/2017","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"35","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2017-05-18"},{"SOURCE_ROW_NUMBER":"220010","EVENT_NO":"6274051","SURVEY_DATE":"05/18/2017","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2017-05-18"},{"SOURCE_ROW_NUMBER":"220009","EVENT_NO":"6274051","SURVEY_DATE":"05/18/2017","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"70","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2017-05-18"},{"SOURCE_ROW_NUMBER":"220008","EVENT_NO":"6274051","SURVEY_DATE":"05/18/2017","OCCUPATION_CD_DESC":"WIREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"39","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2017-05-18"},{"SOURCE_ROW_NUMBER":"220018","EVENT_NO":"6274051","SURVEY_DATE":"05/17/2017","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"49","PEL_DOSE_90":"27","SURVEY_TYPE":"F","sourceDate":"2017-05-17"},{"SOURCE_ROW_NUMBER":"220017","EVENT_NO":"6274051","SURVEY_DATE":"05/17/2017","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"008","ACT_DOSE_85":"107","PEL_DOSE_90":"72","SURVEY_TYPE":"F","sourceDate":"2017-05-17"},{"SOURCE_ROW_NUMBER":"220016","EVENT_NO":"6274051","SURVEY_DATE":"05/17/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (INTAKE SIDE)","MACHINE_CD":"06","MANUFACTURER_CD":"008","ACT_DOSE_85":"132","PEL_DOSE_90":"104","SURVEY_TYPE":"F","sourceDate":"2017-05-17"},{"SOURCE_ROW_NUMBER":"220015","EVENT_NO":"6274051","SURVEY_DATE":"05/17/2017","OCCUPATION_CD_DESC":"LOADING MACHINE OPERATOR","MACHINE_CD":"24","MANUFACTURER_CD":"058","ACT_DOSE_85":"114","PEL_DOSE_90":"92","SURVEY_TYPE":"F","sourceDate":"2017-05-17"},{"SOURCE_ROW_NUMBER":"220014","EVENT_NO":"6274051","SURVEY_DATE":"05/17/2017","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"49","PEL_DOSE_90":"22","SURVEY_TYPE":"F","sourceDate":"2017-05-17"},{"SOURCE_ROW_NUMBER":"220013","EVENT_NO":"6274051","SURVEY_DATE":"05/17/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","MACHINE_CD":"06","MANUFACTURER_CD":"008","ACT_DOSE_85":"112","PEL_DOSE_90":"88","SURVEY_TYPE":"F","sourceDate":"2017-05-17"},{"SOURCE_ROW_NUMBER":"220007","EVENT_NO":"6273969","SURVEY_DATE":"01/30/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"76","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2017-01-30"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":146,"firstDate":"2000-02-15","lastDate":"2017-10-11","metrics":{"recentRows":0,"voidSamples":6,"maxQuartzPct":16.4,"validSamples":140,"quartzPctTotal":279.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"158927","CASSETTE_NO":"58277694","SAMPLE_DT":"10/11/2017","QUARTZ_PCT":"03.6","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"140185","CASSETTE_NO":"58277854","SAMPLE_DT":"10/11/2017","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"82782","CASSETTE_NO":"58277689","SAMPLE_DT":"10/11/2017","QUARTZ_PCT":"02.8","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"55580","CASSETTE_NO":"58277753","SAMPLE_DT":"10/11/2017","QUARTZ_PCT":"01.1","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"32544","CASSETTE_NO":"58277932","SAMPLE_DT":"10/11/2017","QUARTZ_PCT":"02.8","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"120713","CASSETTE_NO":"58277691","SAMPLE_DT":"09/19/2017","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-09-19"},{"SOURCE_ROW_NUMBER":"103350","CASSETTE_NO":"58277804","SAMPLE_DT":"09/19/2017","QUARTZ_PCT":"01.0","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-09-19"},{"SOURCE_ROW_NUMBER":"93152","CASSETTE_NO":"58277931","SAMPLE_DT":"09/19/2017","QUARTZ_PCT":"02.3","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-09-19"},{"SOURCE_ROW_NUMBER":"150945","CASSETTE_NO":"58277967","SAMPLE_DT":"08/30/2017","QUARTZ_PCT":"04.3","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-08-30"},{"SOURCE_ROW_NUMBER":"109570","CASSETTE_NO":"58277821","SAMPLE_DT":"08/30/2017","QUARTZ_PCT":"06.9","QUARTZ_MICROGRAMS":"46","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-08-30"},{"SOURCE_ROW_NUMBER":"60079","CASSETTE_NO":"58277930","SAMPLE_DT":"06/22/2017","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-06-22"},{"SOURCE_ROW_NUMBER":"56264","CASSETTE_NO":"58277744","SAMPLE_DT":"06/22/2017","QUARTZ_PCT":"00.6","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"INVALID SAMPLE TYPE","sourceDate":"2017-06-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":7779,"firstDate":"2000-01-10","lastDate":"2020-08-17","metrics":{"ss":1892,"amountDue":5208955.65,"contested":571,"amountPaid":2888662.63,"recentRows":0,"section104d":104,"unterminated":37,"proposedPenalty":6927976},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2563805","VIOLATION_NO":"9182156","VIOLATION_ISSUE_DT":"08/17/2020","SIG_SUB":"N","PART_SECTION":"77.216-4(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"206","AMOUNT_DUE":"206","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-08-17"},{"SOURCE_ROW_NUMBER":"2563804","VIOLATION_NO":"9182155","VIOLATION_ISSUE_DT":"08/17/2020","PART_SECTION":"77.216-3(a)(1)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"07/02/2021","CONTESTED_IND":"N","sourceDate":"2020-08-17"},{"SOURCE_ROW_NUMBER":"2563803","VIOLATION_NO":"9182154","VIOLATION_ISSUE_DT":"08/17/2020","PART_SECTION":"77.216-3(a)(1)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"07/02/2021","CONTESTED_IND":"N","sourceDate":"2020-08-17"},{"SOURCE_ROW_NUMBER":"2563707","VIOLATION_NO":"9182153","VIOLATION_ISSUE_DT":"07/30/2020","SIG_SUB":"N","PART_SECTION":"77.216-3(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"206","AMOUNT_DUE":"206","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-07-30"},{"SOURCE_ROW_NUMBER":"2563706","VIOLATION_NO":"9182151","VIOLATION_ISSUE_DT":"07/30/2020","SIG_SUB":"N","PART_SECTION":"77.216-3(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"206","AMOUNT_DUE":"206","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-07-30"},{"SOURCE_ROW_NUMBER":"2561716","VIOLATION_NO":"9182152","VIOLATION_ISSUE_DT":"05/11/2020","SIG_SUB":"N","PART_SECTION":"50.10(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2020","PROPOSED_PENALTY":"6159","AMOUNT_DUE":"6159","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"2561715","VIOLATION_NO":"9182150","VIOLATION_ISSUE_DT":"05/11/2020","SIG_SUB":"N","PART_SECTION":"77.1607(u)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"2561714","VIOLATION_NO":"9182149","VIOLATION_ISSUE_DT":"05/11/2020","SIG_SUB":"Y","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/11/2020","PROPOSED_PENALTY":"1738","AMOUNT_DUE":"1738","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"2561713","VIOLATION_NO":"9187411","VIOLATION_ISSUE_DT":"05/11/2020","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/11/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"123","CONTESTED_IND":"N","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"2561712","VIOLATION_NO":"9187410","VIOLATION_ISSUE_DT":"05/11/2020","SIG_SUB":"Y","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/11/2020","PROPOSED_PENALTY":"135","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"2559956","VIOLATION_NO":"9187409","VIOLATION_ISSUE_DT":"05/11/2020","SIG_SUB":"Y","PART_SECTION":"77.1607(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2020","PROPOSED_PENALTY":"1483","AMOUNT_DUE":"1483","AMOUNT_PAID":"1483","CONTESTED_IND":"N","sourceDate":"2020-05-11"},{"SOURCE_ROW_NUMBER":"2560054","VIOLATION_NO":"9182148","VIOLATION_ISSUE_DT":"03/20/2020","SIG_SUB":"N","PART_SECTION":"50.20(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/30/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-03-20"}]}],"safety":{"href":"/api/v1/mines/4601456/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4601456/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Water, sediment or slurry impoundments and impounding structures; reporting requirements; certification.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.216-4","part":"77","subchapter":"O","subpart":"C","id":"77.216-4","citation":"30 CFR 77.216-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Water, sediment, or slurry impoundments and impounding structures; inspection requirements; correction of hazards; program requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.216-3","part":"77","subchapter":"O","subpart":"C","id":"77.216-3","citation":"30 CFR 77.216-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 50.10","heading":"Immediate notification.","id":"50.10","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-B/section-50.10","part":"50","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subchapter":"I","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","subpart":"B","subpartHeading":"Subpart B—Notification, Investigation, Preservation of Evidence","text":"The operator shall immediately contact MSHA at once without delay and within 15 minutes at the toll-free number, 1-800-746-1553, once the operator knows or should know that an accident has occurred involving:\n\n(a) A death of an individual at the mine;\n\n(b) An injury of an individual at the mine which has a reasonable potential to cause death;\n\n(c) An entrapment of an individual at the mine which has a reasonable potential to cause death; or\n\n(d) Any other accident.\n\n[74 FR 68919, Dec. 29, 2009]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1607","heading":"Loading and haulage equipment; operation.","id":"77.1607","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1607","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Vehicles shall follow at a safe distance; passing shall be limited to areas of adequate clearance and visibility.\n\n(b) Mobile equipment operators shall have full control of the equipment while it is in motion.\n\n(c) Equipment operating speeds shall be prudent and consistent with conditions of roadway, grades, clearance, visibility, traffic, and the type of equipment used.\n\n(d) Cabs of mobile equipment shall be kept free of extraneous materials.\n\n(e) Operators shall sit facing the direction of travel while operating equipment with dual controls.\n\n(f) When an equipment operator is present, men shall notify him before getting on or off equipment.\n\n(g) Equipment operators shall be certain, by signal or other means, that all persons are clear before starting or moving equipment.\n\n(h) Where possible, aerial tramways shall not be started until the tramway operator has ascertained that everyone is in the clear.\n\n(i) Dust control measures shall be taken where dust significantly reduces visibility of equipment operators.\n\n(j) Dippers, buckets, loading booms, or heavy suspended loads shall not be swung over the cabs of haulage vehicles until the drivers are out of the cabs and in safe locations, unless the trucks are designed specifically to protect the drivers from falling material.\n\n(k) Men shall not work or pass under the buckets or booms of loaders in operation.\n\n(l) Tires shall be deflated before repairs on them are started and adequate means shall be provided to prevent wheel locking rims from creating a hazard during tire inflation.\n\n(m) Electrically powered mobile equipment shall not be left unattended unless the master switch is in the off position, all operating controls are in the neutral position, and the brakes are set or other equivalent precautions are taken against rolling.\n\n(n) Mobile equipment shall not be left unattended unless the brakes are set. The wheels shall be turned into a bank or berm, or shall be blocked, when such equipment is parked on a grade.\n\n(o) Lights, flares, or other warning devices shall be posted when parked equipment creates a hazard to vehicular traffic.\n\n(p) Dippers, buckets, scraper blades, and similar movable parts shall be secured or lowered to the ground when not in use.\n\n(q) Shovel trailing cables shall not be moved with the shovel dipper unless cable slings or sleds are used.\n\n(r) Equipment which is to be hauled shall be loaded and protected so as to prevent sliding or spillage.\n\n(s) When moving between work areas, the equipment shall be secured in the travel position.\n\n(t) Any load extending more than 4 feet beyond the rear of the vehicle body should be marked clearly with a red flag by day and a red light at night.\n\n(u) Tow bars shall be used to tow heavy equipment and a safety chain shall be used in conjunction with each tow bar.\n\n(v) Railroad cars shall be kept under control at all times by the car dropper. Cars shall be dropped at a safe rate and in a manner that will insure that the car dropper maintains a safe position while working and traveling around the cars.\n\n(w) Railroad cars shall not be coupled or uncoupled manually from the inside of curves unless the railroad and cars are so designed to eliminate any hazard from coupling or uncoupling cars from inside of curves.\n\n(x) Persons shall wear safety belts when dropping railroad cars.\n\n(y) Railcars shall not be left on sidetracks unless ample clearance is provided for traffic on adjacent tracks.\n\n(z) Parked railcars, unless held effectively by brakes, shall be blocked securely.\n\n(aa) Railroad cars and all trucks shall be trimmed properly when they have been loaded higher than the confines of their cargo space.\n\n(bb) When the entire length of a conveyor is visible from the starting switch, the operator shall visually check to make certain that all persons are in the clear before starting the conveyor. When the entire length of the conveyor is not visible from the starting switch, a positive audible or visible warning system shall be installed and operated to warn persons that the conveyor will be started.\n\n(cc) Unguarded conveyors with walkways shall be equipped with emergency stop devices or cords along their full length.\n\n(dd) Adequate backstops or brakes shall be installed on inclined-conveyor drive units to prevent conveyors from running in reverse if a hazard to personnel would be caused.\n\n(ee) Aerial tram conveyor buckets shall not be overloaded, and feed shall be regulated to prevent spillage.","occurrenceCount":2},{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.31","part":"48","subchapter":"H","subpart":"B","id":"48.31","citation":"30 CFR 48.31","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4601456","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}