{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4601387","name":"Spring Branch Mine","status":"Abandoned and Sealed","status_date":"2008-02-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Logan","nearest_town":"Stirrat","operator_id":"P23835","operator_name":"Spartan Mining Company","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C04","office":"Beckley District","employees":0,"latitude":37.766111,"longitude":-82.016666},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":284},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"operator":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00037","name":"W-P Coal Company"},"object":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"validFrom":"1950-01-01","validTo":"2000-04-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|P00037|1950-01-01|2000-04-17"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00014","name":"Wheeling-Pittsburgh Corp"},"object":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|C00014|1950-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00014","name":"Wheeling-Pittsburgh Corp"},"object":{"type":"operator","id":"P00037","name":"W-P Coal Company"},"validFrom":"1950-01-01","validTo":"2000-04-17","current":false,"derived":true,"evidenceMineId":"4601387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|P00037|1950-01-01|C00014|1950-01-01|43466"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"validFrom":"1996-02-05","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|C02508|1996-02-05|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"object":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"validFrom":"2000-04-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|P23835|2000-04-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2000-04-18","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4601387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|P23835|2000-04-18|C02508|1996-02-05|59404"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4601387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|P23835|2000-04-18|0041211|2011-06-01|1931"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"4601387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|P23835|2000-04-18|0127923|2016-07-26|25121"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4601387","name":"Spring Branch Mine"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P23835","name":"Spartan Mining Company"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"4601387","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601387|P23835|2000-04-18|0127321|2018-11-09|24756"}}],"coverage":{"historyRecords":5,"edgeCount":12,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2000-10-09","lastDate":"2000-12-26","metrics":{"daysLost":85,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"141085","DOCUMENT_NO":"220010080142","ACCIDENT_DT":"12/26/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A FALL OCCURRED 100' INBY SPAD 120. FALL IS APP. 35'X19'12'H. AREA WAS SUPPORTED WITH 6' TORQUE TENTION. WATER HAD STATURATED STRATA. A COAL RIDER SEAM 8\" TO 10\" THICK 7' UP WAS PRESENT. AREA HAS BEEN REHABED.","sourceDate":"2000-12-26"},{"SOURCE_ROW_NUMBER":"265854","DOCUMENT_NO":"220010020062","ACCIDENT_DT":"12/11/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"24","NARRATIVE":"EE WAS LIFTING FEEDER CHAIN INTO THE MANTRIP AND STRAINED HIS LOWER BACK. EE HAS SEEN THE DOCTOR AND THE DR DIAGNOSED A LEFT INGUINAL HERNIA WITH SWELLING OF THE GROIN. HE IS STILL WORKING BUT NOT LIFTING HEAVY OBJECTS AND IS LOOKING TO REPAIR THE INJURY BY SURGERY. THIS IS DETERMINED TOBE AN OCCUPATIONAL INJURY.","sourceDate":"2000-12-11"},{"SOURCE_ROW_NUMBER":"106364","DOCUMENT_NO":"220002970131","ACCIDENT_DT":"10/09/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"61","NARRATIVE":"EE WAS STANDING ON SCAFFOLDING MATERAIL 8' UP TRYING TO WEDGE HIGH CRIB. TO REACH THE BACKSIDE HE STEPPED ON THE OUTSIDE OF THE STRUCURE, SLIPPED & FELL, LANDING ON HIS BACK IN ABOUT 6\"OF WAT ER.","sourceDate":"2000-10-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2008-02-12","lastDate":"2008-02-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":17,"firstDate":"2000-08-30","lastDate":"2000-12-26","metrics":{"ss":4,"delinquent":17,"recentRows":0,"paidPenalty":1172,"proposedPenalty":1172,"currentAssessment":1172},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"760484","VIOLATION_NO":"4716170","ISSUE_DT":"12/26/2000","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-26"},{"SOURCE_ROW_NUMBER":"760483","VIOLATION_NO":"4716169","ISSUE_DT":"12/26/2000","CFR_STANDARD_CD":"50.10","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-26"},{"SOURCE_ROW_NUMBER":"760482","VIOLATION_NO":"4716163","ISSUE_DT":"12/18/2000","CFR_STANDARD_CD":"75.1100-2(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-18"},{"SOURCE_ROW_NUMBER":"760481","VIOLATION_NO":"4716161","ISSUE_DT":"12/17/2000","CFR_STANDARD_CD":"75.706","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-17"},{"SOURCE_ROW_NUMBER":"760480","VIOLATION_NO":"4715740","ISSUE_DT":"12/15/2000","CFR_STANDARD_CD":"75.371(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-12-15"},{"SOURCE_ROW_NUMBER":"760479","VIOLATION_NO":"4715738","ISSUE_DT":"11/27/2000","CFR_STANDARD_CD":"75.1106-3(a)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"760478","VIOLATION_NO":"4715736","ISSUE_DT":"11/27/2000","CFR_STANDARD_CD":"75.1100-2(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"760477","VIOLATION_NO":"4715735","ISSUE_DT":"11/27/2000","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"753161","VIOLATION_NO":"7198217","ISSUE_DT":"09/13/2000","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"113.00","CURRENT_ASSESSMENT_AMT":"113.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-09-13"},{"SOURCE_ROW_NUMBER":"753160","VIOLATION_NO":"7198216","ISSUE_DT":"09/12/2000","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"97.00","CURRENT_ASSESSMENT_AMT":"97.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-09-12"},{"SOURCE_ROW_NUMBER":"753159","VIOLATION_NO":"7198215","ISSUE_DT":"09/12/2000","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-09-12"},{"SOURCE_ROW_NUMBER":"753158","VIOLATION_NO":"7198214","ISSUE_DT":"09/12/2000","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2000-09-12"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":5,"firstDate":"2000-12-18","lastDate":"2000-12-21","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":4,"maxConcentration":0.324,"concentrationTotal":0.768},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1360252","CASS_NUM":"50549992","SMP_TAKEN_DT":"12/21/2000","CONC":".011","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-21"},{"SOURCE_ROW_NUMBER":"751822","CASS_NUM":"50550040","SMP_TAKEN_DT":"12/20/2000","CONC":".178","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-20"},{"SOURCE_ROW_NUMBER":"1282080","CASS_NUM":"50550045","SMP_TAKEN_DT":"12/19/2000","CONC":".023","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INSUFFICIENT DUST OBSERVED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-19"},{"SOURCE_ROW_NUMBER":"392937","CASS_NUM":"50550050","SMP_TAKEN_DT":"12/19/2000","CONC":".324","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-19"},{"SOURCE_ROW_NUMBER":"1185201","CASS_NUM":"50550060","SMP_TAKEN_DT":"12/18/2000","CONC":".232","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2000-12-18"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":159,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":42,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1950-01-01","lastDate":"2000-04-18","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":21,"firstDate":"2000-05-16","lastDate":"2001-01-08","metrics":{"inspectors":29,"recentRows":0,"onSiteHours":204.5,"inspectionHours":396,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"466882","EVENT_NO":"4090016","INSPECTION_BEGIN_DT":"01/08/2001","INSPECTION_END_DT":"01/31/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2001-01-08"},{"SOURCE_ROW_NUMBER":"804614","EVENT_NO":"4091490","INSPECTION_BEGIN_DT":"01/04/2001","INSPECTION_END_DT":"01/08/2001","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2001-01-04"},{"SOURCE_ROW_NUMBER":"712686","EVENT_NO":"4091763","INSPECTION_BEGIN_DT":"01/03/2001","INSPECTION_END_DT":"01/05/2001","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2001-01-03"},{"SOURCE_ROW_NUMBER":"323122","EVENT_NO":"4088682","INSPECTION_BEGIN_DT":"12/19/2000","INSPECTION_END_DT":"12/19/2000","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2000-12-19"},{"SOURCE_ROW_NUMBER":"71349","EVENT_NO":"5913820","INSPECTION_BEGIN_DT":"12/11/2000","INSPECTION_END_DT":"12/28/2000","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2000-12-11"},{"SOURCE_ROW_NUMBER":"455682","EVENT_NO":"4091481","INSPECTION_BEGIN_DT":"11/27/2000","INSPECTION_END_DT":"12/01/2000","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"32.75","SUM_TOTAL_ON_SITE_HOURS":"16.25","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"113277","EVENT_NO":"4090013","INSPECTION_BEGIN_DT":"11/22/2000","INSPECTION_END_DT":"12/28/2000","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"65.5","SUM_TOTAL_ON_SITE_HOURS":"44","sourceDate":"2000-11-22"},{"SOURCE_ROW_NUMBER":"696296","EVENT_NO":"4088679","INSPECTION_BEGIN_DT":"11/13/2000","INSPECTION_END_DT":"11/13/2000","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2000-11-13"},{"SOURCE_ROW_NUMBER":"758466","EVENT_NO":"4091478","INSPECTION_BEGIN_DT":"11/07/2000","INSPECTION_END_DT":"11/14/2000","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2000-11-07"},{"SOURCE_ROW_NUMBER":"1112896","EVENT_NO":"4091468","INSPECTION_BEGIN_DT":"10/03/2000","INSPECTION_END_DT":"10/12/2000","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"44","SUM_TOTAL_ON_SITE_HOURS":"19","sourceDate":"2000-10-03"},{"SOURCE_ROW_NUMBER":"269396","EVENT_NO":"4091458","INSPECTION_BEGIN_DT":"09/11/2000","INSPECTION_END_DT":"09/11/2000","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2000-09-11"},{"SOURCE_ROW_NUMBER":"175957","EVENT_NO":"4088672","INSPECTION_BEGIN_DT":"09/07/2000","INSPECTION_END_DT":"09/07/2000","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2000-09-07"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008-Q1":{"hours":0,"employees":0,"production":0},"2001-Q1":{"hours":1987,"employees":5,"production":375},"2000-Q4":{"hours":14953,"employees":25,"production":17705},"2000-Q3":{"hours":9677,"employees":20,"production":0},"2000-Q2":{"hours":531,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":25161,"employees":17,"production":17705},"2001":{"hours":1987,"employees":5,"production":375}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":20,"firstDate":"2000-08-30","lastDate":"2000-12-26","metrics":{"ss":4,"amountDue":1172,"contested":0,"amountPaid":1172,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":1172},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2508886","VIOLATION_NO":"4716170","VIOLATION_ISSUE_DT":"12/26/2000","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/26/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-12-26"},{"SOURCE_ROW_NUMBER":"2508885","VIOLATION_NO":"4716169","VIOLATION_ISSUE_DT":"12/26/2000","SIG_SUB":"N","PART_SECTION":"50.10","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/26/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-12-26"},{"SOURCE_ROW_NUMBER":"2508884","VIOLATION_NO":"4716163","VIOLATION_ISSUE_DT":"12/18/2000","SIG_SUB":"N","PART_SECTION":"75.1100-2(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/19/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-12-18"},{"SOURCE_ROW_NUMBER":"2508883","VIOLATION_NO":"4716162","VIOLATION_ISSUE_DT":"12/18/2000","PART_SECTION":"75.1403-6(a)(1)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"01/31/2001","CONTESTED_IND":"N","sourceDate":"2000-12-18"},{"SOURCE_ROW_NUMBER":"2508882","VIOLATION_NO":"4716161","VIOLATION_ISSUE_DT":"12/17/2000","SIG_SUB":"N","PART_SECTION":"75.706","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-12-17"},{"SOURCE_ROW_NUMBER":"2508881","VIOLATION_NO":"4715740","VIOLATION_ISSUE_DT":"12/15/2000","SIG_SUB":"N","PART_SECTION":"75.371(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/19/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-12-15"},{"SOURCE_ROW_NUMBER":"2508880","VIOLATION_NO":"4715738","VIOLATION_ISSUE_DT":"11/27/2000","SIG_SUB":"Y","PART_SECTION":"75.1106-3(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/13/2000","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"2508879","VIOLATION_NO":"4715737","VIOLATION_ISSUE_DT":"11/27/2000","PART_SECTION":"75.1403-6(b)(1)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"12/13/2000","CONTESTED_IND":"N","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"2508878","VIOLATION_NO":"4715736","VIOLATION_ISSUE_DT":"11/27/2000","SIG_SUB":"N","PART_SECTION":"75.1100-2(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/13/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"2508877","VIOLATION_NO":"4715735","VIOLATION_ISSUE_DT":"11/27/2000","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/13/2000","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2000-11-27"},{"SOURCE_ROW_NUMBER":"2508876","VIOLATION_NO":"7198217","VIOLATION_ISSUE_DT":"09/13/2000","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/18/2000","PROPOSED_PENALTY":"113","AMOUNT_DUE":"113","AMOUNT_PAID":"113","CONTESTED_IND":"N","sourceDate":"2000-09-13"},{"SOURCE_ROW_NUMBER":"2508875","VIOLATION_NO":"7198216","VIOLATION_ISSUE_DT":"09/12/2000","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/13/2000","PROPOSED_PENALTY":"97","AMOUNT_DUE":"97","AMOUNT_PAID":"97","CONTESTED_IND":"N","sourceDate":"2000-09-12"}]}],"safety":{"href":"/api/v1/mines/4601387/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4601387/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 50.10","heading":"Immediate notification.","id":"50.10","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-B/section-50.10","part":"50","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subchapter":"I","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","subpart":"B","subpartHeading":"Subpart B—Notification, Investigation, Preservation of Evidence","text":"The operator shall immediately contact MSHA at once without delay and within 15 minutes at the toll-free number, 1-800-746-1553, once the operator knows or should know that an accident has occurred involving:\n\n(a) A death of an individual at the mine;\n\n(b) An injury of an individual at the mine which has a reasonable potential to cause death;\n\n(c) An entrapment of an individual at the mine which has a reasonable potential to cause death; or\n\n(d) Any other accident.\n\n[74 FR 68919, Dec. 29, 2009]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-6","heading":"Criteria—Self-propelled personnel carriers.","id":"75.1403-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Each self-propelled personnel carrier should:\n\n(1) Be provided with an audible warning device;\n\n(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;\n\n(3) Be provided with reflectors on both ends and sides.\n\n(b) In addition, each track-mounted self-propelled personnel carrier should:\n\n(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;\n\n(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;\n\n(3) Be equipped with properly installed and well-maintained sanding devices, except that personnel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;\n\n(4) If an open type, be equipped with guards of sufficient strength and height to prevent personnel from being thrown from such carriers.","occurrenceCount":2},{"chapter":"I","heading":"Deenergized underground power circuits; idle days—idle shifts.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-H/section-75.706","part":"75","subchapter":"O","subpart":"H","id":"75.706","citation":"30 CFR 75.706","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Mine ventilation plan; contents.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.371","part":"75","subchapter":"O","subpart":"D","id":"75.371","citation":"30 CFR 75.371","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4601387","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}