{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4601318","name":"Harrison County Mine","status":"Active","status_date":"1999-05-20","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"WV","county":"Wetzel","nearest_town":"Mannington","operator_id":"0173633","operator_name":"Harrison County Coal Resources, Inc.","controller_id":"0157801","controller_name":"ACNR Holdings, Inc","district":"C03","office":"Bridgeport WV Field Office","employees":400,"latitude":39.475278,"longitude":-80.496389},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":75312},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"operator":{"type":"operator","id":"0173633","name":"Harrison County Coal Resources, Inc."},"controller":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"object":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"validFrom":"1950-01-01","validTo":"2016-01-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|P00812|1950-01-01|2016-01-03"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"validFrom":"1950-01-01","validTo":"2013-12-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|C00692|1950-01-01|2013-12-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"validFrom":"1950-01-01","validTo":"2013-12-04","current":false,"derived":true,"evidenceMineId":"4601318","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|P00812|1950-01-01|C00692|1950-01-01|49128"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"validFrom":"2013-12-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|C13408|2013-12-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"validFrom":"2013-12-05","validTo":"2016-01-03","current":false,"derived":true,"evidenceMineId":"4601318","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|P00812|1950-01-01|C13408|2013-12-05|89701"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0143073","name":"The Harrison County Coal Company"},"object":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"validFrom":"2016-01-04","validTo":"2020-09-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|0143073|2016-01-04|2020-09-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"validFrom":"2016-01-04","validTo":"2020-09-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|C13408|2016-01-04|2020-09-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"0143073","name":"The Harrison County Coal Company"},"validFrom":"2016-01-04","validTo":"2020-09-16","current":false,"derived":true,"evidenceMineId":"4601318","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|0143073|2016-01-04|C13408|2016-01-04|89799"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|0157801|2020-09-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"operator","id":"0143073","name":"The Harrison County Coal Company"},"validFrom":"2020-09-17","validTo":"2020-09-16","current":false,"derived":true,"evidenceMineId":"4601318","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|0143073|2016-01-04|0157801|2020-09-17|32657"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0173633","name":"Harrison County Coal Resources, Inc."},"object":{"type":"mine","id":"4601318","name":"Harrison County Mine"},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|0173633|2020-09-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"operator","id":"0173633","name":"Harrison County Coal Resources, Inc."},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4601318","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4601318|0173633|2020-09-17|0157801|2020-09-17|32658"}}],"coverage":{"historyRecords":5,"edgeCount":12,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1107,"firstDate":"2000-02-23","lastDate":"2026-09-10","metrics":{"daysLost":39441,"injuries":970,"fatalities":2,"recentRows":225,"restrictedDays":382,"contractorRecords":96},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"274376","DOCUMENT_NO":"220262590013","ACCIDENT_DT":"09/10/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"Injured employee was lifting a submersible pump at the Slope MCC bottom to clean mud off the suction end when EE slipped and felt a pull in EE's lower abdomen & left upper leg/groin area. Injured has training and experience. Wearing required PPE at time.","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"141081","DOCUMENT_NO":"220262530016","ACCIDENT_DT":"09/01/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was picking up a shuttle car cable and moving it out of roadway when they lost balance and fell down, landing on right knee. Suffered contusion/pain/swelling. Missed 2 days of work. Was wearing required PPE at time of injury.","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"257264","DOCUMENT_NO":"220262430028","ACCIDENT_DT":"08/19/2026","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall was discovered outby the working sections at the 3 West Seal rehab area. The approximate size of the roof fall is 16 ft. wide, 20 ft. Long and 8 1/2 to 9 ft. high. The area was initially bolted with resin assisted, 8 ft., 2-piece combination bolts. There were no injuries, equipment damage or impaired ventilation as a result of the fall. Area has been re-supported.","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"76604","DOCUMENT_NO":"220262380010","ACCIDENT_DT":"08/18/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee was working on the 9W CM Section as a Roof Bolter. EE was pulling the trailing cable off the cable reel when EE felt pain in EE's lower back. Was diagnosed with a lower back strain and missed 4 days of work. Employee has training and experience and wearing required PPE.","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"33599","DOCUMENT_NO":"220262380009","ACCIDENT_DT":"08/18/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"Employee was working on the 9W CM Section. Was walking from the face to the auxiliary fan when EE tripped on a rock and fell down, landing on EE's SCSR EE was wearing.","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"119413","DOCUMENT_NO":"220262240007","ACCIDENT_DT":"08/07/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","NARRATIVE":"Employee was operating a shuttle car on the 7 North Mains CM Section. EE stopped to remove a rock from the roadway. When EE tossed the rock in the shuttle car boom, EE felt a \"pop\" in EE's left bicep. Employee has a torn bicep muscle. EE has training and experience and wearing required PPE at time of accident.","sourceDate":"2026-08-07"},{"SOURCE_ROW_NUMBER":"244326","DOCUMENT_NO":"220262220019","ACCIDENT_DT":"08/05/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Belt vulcanizer","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was preparing conveyor belt for a vulcanized splice when they knelt onto a razor knife causing a laceration to their right knee resulting in three sutures.","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"265852","DOCUMENT_NO":"220261900028","ACCIDENT_DT":"07/01/2026","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"Injured employee was opening the North Approach door to the 7 North Shaft. As EE turned the latch handle, the pressure on the door caused it to pull away from EE. EE's right little finger was smashed between the door frame and door handle. EE instinctively jerked EE's hand out from between the handle and frame. This resulted in a partial amputation of EE's little finger.","sourceDate":"2026-07-01"},{"SOURCE_ROW_NUMBER":"110750","DOCUMENT_NO":"220261820027","ACCIDENT_DT":"06/23/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"Injured employee was using a large hammer to knock a de-watering screen into place. They struck the screen and the hammer bounced back and hit their left knee. Suffered a deep bruise/contusion. Employee has training and experience and was wearing required PPE.","sourceDate":"2026-06-23"},{"SOURCE_ROW_NUMBER":"127956","DOCUMENT_NO":"220261800009","ACCIDENT_DT":"06/19/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Stopping builder, Ventilation man, Mason man, Overcast","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Injured employee was carrying an angle grinder and other hand tools in EE's arms in a crossed/folded position. As EE was walking, EE inadvertently activated the trigger on the grinder causing it to turn on briefly. The cutting wheel of the grinder contacted EE's right forearm causing a cut. EE received 8 sutures to close the wound.","sourceDate":"2026-06-19"},{"SOURCE_ROW_NUMBER":"222786","DOCUMENT_NO":"220261750002","ACCIDENT_DT":"06/18/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Injured employee and co-worker were removing a top belt cradle for replacement. As they were lifting the cradle out from the belt, they failed to maintain control of the of it and it rolled over and smashed EE's left hand between the cradle and the belt bedrail. Injured had swelling and contusion to EE's hand. Has training and experience. Was wearing metacarpal gloves.","sourceDate":"2026-06-18"},{"SOURCE_ROW_NUMBER":"89421","DOCUMENT_NO":"220261800008","ACCIDENT_DT":"06/18/2026","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"Employee was working on the 7 North Mains Continuous Miner. EE went to step over a mound of coal/dirt and felt several \"pops\" in EE's upper left hamstring. Employee has been diagnosed with a torn left hamstring. Employee has training and experience. Was wearing required PPE.","sourceDate":"2026-06-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"1999-05-20","lastDate":"1999-05-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":14664,"firstDate":"2000-01-04","lastDate":"2026-08-15","metrics":{"ss":3953,"delinquent":14430,"recentRows":1725,"paidPenalty":8907637.91,"proposedPenalty":11927568.2,"currentAssessment":9135008.76},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3009059","VIOLATION_NO":"5150438","ISSUE_DT":"08/15/2026","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"959.00","CURRENT_ASSESSMENT_AMT":"959.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-15"},{"SOURCE_ROW_NUMBER":"3009058","VIOLATION_NO":"5150437","ISSUE_DT":"08/15/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-15"},{"SOURCE_ROW_NUMBER":"3009057","VIOLATION_NO":"5150436","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"3009056","VIOLATION_NO":"5150435","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"3009055","VIOLATION_NO":"5150434","ISSUE_DT":"08/12/2026","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-12"},{"SOURCE_ROW_NUMBER":"3009075","VIOLATION_NO":"9582557","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.331(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"432.00","CURRENT_ASSESSMENT_AMT":"432.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"3009074","VIOLATION_NO":"9582556","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.1722(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1431.00","CURRENT_ASSESSMENT_AMT":"1431.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"3009073","VIOLATION_NO":"9582555","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"3009054","VIOLATION_NO":"5150433","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.1002(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"193.00","CURRENT_ASSESSMENT_AMT":"193.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"3009053","VIOLATION_NO":"5150432","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"3009052","VIOLATION_NO":"5150431","ISSUE_DT":"08/11/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"209.00","CURRENT_ASSESSMENT_AMT":"209.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-11"},{"SOURCE_ROW_NUMBER":"3038516","VIOLATION_NO":"9582554","ISSUE_DT":"08/10/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"366.00","CURRENT_ASSESSMENT_AMT":"366.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-10"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3082,"firstDate":"2000-05-10","lastDate":"2026-08-06","metrics":{"appeals":5,"decisions":3075,"recentRows":153,"decisionPenalty":4805434.66,"originalPenalty":7689721.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"463168","VIOLATION_NO":"9938544","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"313.00","DECISION_PENALTY_AMT":"245.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"462080","VIOLATION_NO":"9938551","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"288.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"462079","VIOLATION_NO":"9586580","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"549.00","DECISION_PENALTY_AMT":"549.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"168831","VIOLATION_NO":"9583937","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"549.00","DECISION_PENALTY_AMT":"397.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"168419","VIOLATION_NO":"9938546","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1818.00","DECISION_PENALTY_AMT":"366.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"168418","VIOLATION_NO":"9527669","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4047.00","DECISION_PENALTY_AMT":"1818.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"460076","VIOLATION_NO":"8059798","DOCKET_NO":"WEVA 2026-0015","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"366.00","DECISION_PENALTY_AMT":"245.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"459573","VIOLATION_NO":"9935085","DOCKET_NO":"WEVA 2026-0015","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4047.00","DECISION_PENALTY_AMT":"2432.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"459572","VIOLATION_NO":"9934763","DOCKET_NO":"WEVA 2026-0015","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"366.00","DECISION_PENALTY_AMT":"245.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"459490","VIOLATION_NO":"9935082","DOCKET_NO":"WEVA 2026-0015","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2936.00","DECISION_PENALTY_AMT":"1320.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"459489","VIOLATION_NO":"9935068","DOCKET_NO":"WEVA 2026-0015","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1219.00","DECISION_PENALTY_AMT":"732.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"},{"SOURCE_ROW_NUMBER":"459488","VIOLATION_NO":"9935067","DOCKET_NO":"WEVA 2026-0015","DECISION_DT":"06/11/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"818.00","DECISION_PENALTY_AMT":"258.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2026-06-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":17880,"firstDate":"2000-01-05","lastDate":"2026-10-07","metrics":{"recentRows":5858,"cpdmSamples":9482,"voidSamples":7252,"validSamples":10628,"maxConcentration":215.946,"concentrationTotal":9732.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2688860","SMP_TAKEN_DT":"10/7/2026","CONC":".524","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2688859","SMP_TAKEN_DT":"10/7/2026","CONC":".664","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2432747","SMP_TAKEN_DT":"10/7/2026","CONC":".221","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2347775","SMP_TAKEN_DT":"10/7/2026","CONC":".928","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2262741","SMP_TAKEN_DT":"10/7/2026","CONC":".826","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"1751330","SMP_TAKEN_DT":"10/7/2026","CONC":".675","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"3029451","SMP_TAKEN_DT":"10/6/2026","CONC":"1.1","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2858663","SMP_TAKEN_DT":"10/6/2026","CONC":".427","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2602789","SMP_TAKEN_DT":"10/6/2026","CONC":".211","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2346577","SMP_TAKEN_DT":"10/6/2026","CONC":".873","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2091039","SMP_TAKEN_DT":"10/6/2026","CONC":".632","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"1750419","SMP_TAKEN_DT":"10/6/2026","CONC":".259","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1629,"firstDate":"2000-01-18","lastDate":"2026-10-05","metrics":{"linkedIssuances":1629},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2777,"firstDate":"2001-11-05","lastDate":"2026-07-08","metrics":{"decisions":2770,"ssChanged":298,"recentRows":150,"decisionPenalty":4419130.76,"proposedPenalty":7150384},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"54376","CITATION_NO":"9188263","CITATION_ISSUE_DT":"07/08/2026","DOCKET_NO":"WEVA 2026-0399","CFR_STANDARD_CODE":"75.380(d)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"642.00","sourceDate":"2026-07-08"},{"SOURCE_ROW_NUMBER":"393311","CITATION_NO":"9188254","CITATION_ISSUE_DT":"06/03/2026","DOCKET_NO":"WEVA 2026-0400","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7676.00","sourceDate":"2026-06-03"},{"SOURCE_ROW_NUMBER":"168420","CITATION_NO":"9938553","CITATION_ISSUE_DT":"01/13/2026","DOCKET_NO":"WEVA 2026-0366","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1219.00","sourceDate":"2026-01-13"},{"SOURCE_ROW_NUMBER":"451882","CITATION_NO":"9938551","CITATION_ISSUE_DT":"01/08/2026","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"642.00","DECISION_PENALTY_AMT":"288.00","sourceDate":"2026-01-08"},{"SOURCE_ROW_NUMBER":"223839","CITATION_NO":"9586580","CITATION_ISSUE_DT":"12/30/2025","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"549.00","DECISION_PENALTY_AMT":"549.00","sourceDate":"2025-12-30"},{"SOURCE_ROW_NUMBER":"223626","CITATION_NO":"9938546","CITATION_ISSUE_DT":"12/22/2025","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","CFR_STANDARD_CODE":"75.606","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1818.00","DECISION_PENALTY_AMT":"366.00","sourceDate":"2025-12-22"},{"SOURCE_ROW_NUMBER":"393219","CITATION_NO":"9938544","CITATION_ISSUE_DT":"12/17/2025","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"313.00","DECISION_PENALTY_AMT":"245.00","sourceDate":"2025-12-17"},{"SOURCE_ROW_NUMBER":"165150","CITATION_NO":"9527700","CITATION_ISSUE_DT":"11/05/2025","DOCKET_NO":"WEVA 2026-0093","DECISION_DT":"02/06/2026","CFR_STANDARD_CODE":"77.1607(n)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"267.00","DECISION_PENALTY_AMT":".00","sourceDate":"2025-11-05"},{"SOURCE_ROW_NUMBER":"281137","CITATION_NO":"9583942","CITATION_ISSUE_DT":"09/03/2025","DOCKET_NO":"WEVA 2026-0034","DECISION_DT":"03/10/2026","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"313.00","DECISION_PENALTY_AMT":"232.00","sourceDate":"2025-09-03"},{"SOURCE_ROW_NUMBER":"53993","CITATION_NO":"9527669","CITATION_ISSUE_DT":"08/28/2025","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4047.00","DECISION_PENALTY_AMT":"1818.00","sourceDate":"2025-08-28"},{"SOURCE_ROW_NUMBER":"223362","CITATION_NO":"9583937","CITATION_ISSUE_DT":"08/21/2025","DOCKET_NO":"WEVA 2026-0179","DECISION_DT":"08/06/2026","CFR_STANDARD_CODE":"77.206(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"549.00","DECISION_PENALTY_AMT":"397.00","sourceDate":"2025-08-21"},{"SOURCE_ROW_NUMBER":"336518","CITATION_NO":"9583932","CITATION_ISSUE_DT":"08/13/2025","DOCKET_NO":"WEVA 2026-0015","DECISION_DT":"06/11/2026","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1431.00","DECISION_PENALTY_AMT":"642.00","sourceDate":"2025-08-13"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":11596,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":80,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":2210,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":78,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1950-01-01","lastDate":"2020-09-17","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":3354,"firstDate":"2000-01-04","lastDate":"2026-10-08","metrics":{"inspectors":4927,"recentRows":733,"onSiteHours":90261.25,"inspectionHours":138040,"inspectionSamples":5068},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"627253","EVENT_NO":"F03FB39","INSPECTION_BEGIN_DT":"10/08/2026","INSPECTION_END_DT":"10/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"325774","EVENT_NO":"7042915","INSPECTION_BEGIN_DT":"10/05/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"28","SUM_TOTAL_ON_SITE_HOURS":"14.75","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"1008326","EVENT_NO":"F011722","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"35.5","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"191528","EVENT_NO":"F03FB38","INSPECTION_BEGIN_DT":"10/01/2026","INSPECTION_END_DT":"10/01/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"957379","EVENT_NO":"F011721","INSPECTION_BEGIN_DT":"09/28/2026","INSPECTION_END_DT":"09/28/2026","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"855056","EVENT_NO":"F03FB37","INSPECTION_BEGIN_DT":"09/28/2026","INSPECTION_END_DT":"09/28/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"811028","EVENT_NO":"F012B8D","INSPECTION_BEGIN_DT":"09/22/2026","INSPECTION_END_DT":"09/22/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.25","SUM_TOTAL_ON_SITE_HOURS":"5.75","sourceDate":"2026-09-22"},{"SOURCE_ROW_NUMBER":"735820","EVENT_NO":"F03FB36","INSPECTION_BEGIN_DT":"09/21/2026","INSPECTION_END_DT":"09/21/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-21"},{"SOURCE_ROW_NUMBER":"158134","EVENT_NO":"F011720","INSPECTION_BEGIN_DT":"09/17/2026","INSPECTION_END_DT":"09/17/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-09-17"},{"SOURCE_ROW_NUMBER":"327066","EVENT_NO":"F03FB35","INSPECTION_BEGIN_DT":"09/16/2026","INSPECTION_END_DT":"09/17/2026","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-16"},{"SOURCE_ROW_NUMBER":"1106612","EVENT_NO":"F01171F","INSPECTION_BEGIN_DT":"09/11/2026","INSPECTION_END_DT":"09/11/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"870852","EVENT_NO":"F011435","INSPECTION_BEGIN_DT":"09/09/2026","INSPECTION_END_DT":"09/09/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2026-09-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":424,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":284079,"employees":444,"production":1724448},"2026-Q1":{"hours":271819,"employees":429,"production":893277},"2025-Q4":{"hours":263938,"employees":429,"production":1583626},"2025-Q3":{"hours":280838,"employees":437,"production":1375044},"2025-Q2":{"hours":273756,"employees":439,"production":1567735},"2025-Q1":{"hours":266948,"employees":424,"production":1234497},"2024-Q4":{"hours":258754,"employees":424,"production":1250936},"2024-Q3":{"hours":249230,"employees":426,"production":1730796},"2024-Q2":{"hours":235029,"employees":425,"production":1446924},"2024-Q1":{"hours":244786,"employees":421,"production":1150551},"2023-Q4":{"hours":248443,"employees":434,"production":1651002},"2023-Q3":{"hours":261509,"employees":441,"production":1747220}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":108,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":1061983,"employees":452,"production":7131341},"2018":{"hours":1106333,"employees":454,"production":7215143},"2019":{"hours":1102694,"employees":459,"production":6808868},"2020":{"hours":879177,"employees":390,"production":4880471},"2021":{"hours":918045,"employees":394,"production":6149291},"2022":{"hours":978180,"employees":412,"production":7039318},"2023":{"hours":1038089,"employees":435,"production":7049832},"2024":{"hours":987799,"employees":424,"production":5579207},"2025":{"hours":1085480,"employees":432,"production":5760902},"2026":{"hours":555898,"employees":437,"production":2617725}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":1071,"firstDate":"2000-01-24","lastDate":"2026-03-13","metrics":{"recentRows":188,"doseOver100":369,"actDoseTotal":98323,"pelDoseTotal":80825},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"216342","EVENT_NO":"F01C7DF","SURVEY_DATE":"03/13/2026","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"40","ACT_DOSE_85":"53","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2026-03-13"},{"SOURCE_ROW_NUMBER":"216341","EVENT_NO":"F01C7DF","SURVEY_DATE":"03/13/2026","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"40","ACT_DOSE_85":"54","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2026-03-13"},{"SOURCE_ROW_NUMBER":"216340","EVENT_NO":"F01C7DF","SURVEY_DATE":"03/13/2026","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"40","ACT_DOSE_85":"80","PEL_DOSE_90":"70","SURVEY_TYPE":"I","sourceDate":"2026-03-13"},{"SOURCE_ROW_NUMBER":"216339","EVENT_NO":"F01C7DF","SURVEY_DATE":"03/13/2026","OCCUPATION_CD_DESC":"MOTORMAN","MACHINE_CD":"40","ACT_DOSE_85":"50","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2026-03-13"},{"SOURCE_ROW_NUMBER":"216338","EVENT_NO":"F016824","SURVEY_DATE":"11/25/2025","OCCUPATION_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","MACHINE_CD":"27","ACT_DOSE_85":"80","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2025-11-25"},{"SOURCE_ROW_NUMBER":"216337","EVENT_NO":"F016824","SURVEY_DATE":"11/25/2025","OCCUPATION_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","MACHINE_CD":"27","ACT_DOSE_85":"75","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2025-11-25"},{"SOURCE_ROW_NUMBER":"216336","EVENT_NO":"F016824","SURVEY_DATE":"11/25/2025","OCCUPATION_CD_DESC":"JACK SETTER (LONGWALL)","MACHINE_CD":"40","ACT_DOSE_85":"39","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2025-11-25"},{"SOURCE_ROW_NUMBER":"216335","EVENT_NO":"F016824","SURVEY_DATE":"11/25/2025","OCCUPATION_CD_DESC":"HEADGATE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"111","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2025-11-25"},{"SOURCE_ROW_NUMBER":"216334","EVENT_NO":"F016824","SURVEY_DATE":"11/25/2025","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"20","ACT_DOSE_85":"61","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2025-11-25"},{"SOURCE_ROW_NUMBER":"216333","EVENT_NO":"F016824","SURVEY_DATE":"10/16/2025","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","ACT_DOSE_85":"36","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2025-10-16"},{"SOURCE_ROW_NUMBER":"216332","EVENT_NO":"F016824","SURVEY_DATE":"10/16/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"12","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2025-10-16"},{"SOURCE_ROW_NUMBER":"216331","EVENT_NO":"F016824","SURVEY_DATE":"10/16/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"45","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2025-10-16"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":508,"firstDate":"2000-01-06","lastDate":"2026-09-09","metrics":{"recentRows":204,"voidSamples":24,"maxQuartzPct":19.6,"validSamples":484,"quartzPctTotal":1413.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"33129","CASSETTE_NO":"58596687","SAMPLE_DT":"09/09/2026","QUARTZ_PCT":"01.4","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"4609","CASSETTE_NO":"58596471","SAMPLE_DT":"09/09/2026","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"17504","CASSETTE_NO":"58601125","SAMPLE_DT":"08/28/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"162103","CASSETTE_NO":"58601228","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"204","CASSETTE_NO":"58601140","SAMPLE_DT":"08/26/2026","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"144536","CASSETTE_NO":"58565696","SAMPLE_DT":"05/15/2026","QUARTZ_PCT":"01.5","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"JACK SETTER (LONGWALL)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-15"},{"SOURCE_ROW_NUMBER":"139499","CASSETTE_NO":"58565603","SAMPLE_DT":"05/15/2026","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-15"},{"SOURCE_ROW_NUMBER":"136558","CASSETTE_NO":"58565591","SAMPLE_DT":"05/15/2026","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-15"},{"SOURCE_ROW_NUMBER":"168194","CASSETTE_NO":"58565705","SAMPLE_DT":"05/07/2026","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"30","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-07"},{"SOURCE_ROW_NUMBER":"129063","CASSETTE_NO":"58565593","SAMPLE_DT":"05/07/2026","QUARTZ_PCT":"02.3","QUARTZ_MICROGRAMS":"28","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-07"},{"SOURCE_ROW_NUMBER":"58774","CASSETTE_NO":"58565613","SAMPLE_DT":"05/01/2026","QUARTZ_PCT":"04.1","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-01"},{"SOURCE_ROW_NUMBER":"22565","CASSETTE_NO":"58565333","SAMPLE_DT":"05/01/2026","QUARTZ_PCT":"03.4","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-01"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":14895,"firstDate":"2000-01-04","lastDate":"2026-10-08","metrics":{"ss":3984,"amountDue":9135008.76,"contested":1137,"amountPaid":8907637.91,"recentRows":1823,"section104d":135,"unterminated":11,"proposedPenalty":11927568.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2505609","VIOLATION_NO":"9253058","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2505608","VIOLATION_NO":"9253057","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2505607","VIOLATION_NO":"9253056","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"N","PART_SECTION":"75.601","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2505601","VIOLATION_NO":"5150480","VIOLATION_ISSUE_DT":"10/08/2026","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"2505600","VIOLATION_NO":"5150479","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2505599","VIOLATION_NO":"5150478","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2505598","VIOLATION_NO":"5150477","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2505597","VIOLATION_NO":"5150476","VIOLATION_ISSUE_DT":"10/07/2026","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(vi)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2026","CONTESTED_IND":"N","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2507237","VIOLATION_NO":"9253055","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2507236","VIOLATION_NO":"9253054","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1714-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2505606","VIOLATION_NO":"5150582","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2505605","VIOLATION_NO":"5150581","VIOLATION_ISSUE_DT":"10/06/2026","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/08/2026","CONTESTED_IND":"N","sourceDate":"2026-10-06"}]}],"safety":{"href":"/api/v1/mines/4601318/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4601318/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":424,"companyType":"Operating Subsidiary","components":[{"averageEmployees":424,"laborHours":987799,"mineType":"Underground","productionTons":5579207}],"county":"Wetzel","laborHours":987799,"mineName":"Harrison County Mine","mineType":"Underground","mshaId":"4601318","operatingAddress":"464 North Portal Road, Wallace, WV 26448","operatingCompany":"Harrison County Coal Resources","operationType":"Mine and Preparation Plant","productionTons":5579207,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"West Virginia (Northern)","status":"Active","supplyRegion":"Appalachia Northern","union":"United Mine Workers Of America","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","heading":"Short circuit protection of trailing cables.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601","part":"75","subchapter":"O","subpart":"G","id":"75.601","citation":"30 CFR 75.601","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4601318","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}