{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4407220","name":"JV 17 Mine","status":"Abandoned","status_date":"2026-08-13","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Buchanan","nearest_town":"JEWELL RIDGE","operator_id":"0172933","operator_name":"Mountaineer Metallurgical Holdings LLC","controller_id":"0157861","controller_name":"C6 Ventures LLC; Mark  Nelson","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.239444,"longitude":-81.783056},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":8485},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"operator":{"type":"operator","id":"0172933","name":"Mountaineer Metallurgical Holdings LLC"},"controller":{"type":"controller","id":"0157861","name":"C6 Ventures LLC; Mark  Nelson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"1979-10-29","validTo":"2012-01-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|C01767|1979-10-29|2012-01-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02509","name":"Perry Allen  Whited"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2004-12-21","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|C02509|2004-12-21|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P10904","name":"Dominion Coal Corporation"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2008-04-08","validTo":"2013-12-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|P10904|2008-04-08|2013-12-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"operator","id":"P10904","name":"Dominion Coal Corporation"},"validFrom":"2008-04-08","validTo":"2012-01-16","current":false,"derived":true,"evidenceMineId":"4407220","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|P10904|2008-04-08|C01767|1979-10-29|55934"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2009-05-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|C15863|2009-05-08|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0104093","name":"SunCoke Energy Incorporated"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2012-01-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0104093|2012-01-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0104093","name":"SunCoke Energy Incorporated"},"object":{"type":"operator","id":"P10904","name":"Dominion Coal Corporation"},"validFrom":"2012-01-17","validTo":"2013-12-29","current":false,"derived":true,"evidenceMineId":"4407220","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|P10904|2008-04-08|0104093|2012-01-17|18088"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0056119","name":"SANW, Inc."},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2013-12-30","validTo":"2016-03-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0056119|2013-12-30|2016-03-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02509","name":"Perry Allen  Whited"},"object":{"type":"operator","id":"0056119","name":"SANW, Inc."},"validFrom":"2013-12-30","validTo":"2016-03-30","current":false,"derived":true,"evidenceMineId":"4407220","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0056119|2013-12-30|C02509|2004-12-21|59649"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0100767","name":"Blackjewel L.L.C."},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2016-03-31","validTo":"2019-09-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0100767|2016-03-31|2019-09-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"operator","id":"0100767","name":"Blackjewel L.L.C."},"validFrom":"2016-03-31","validTo":"2019-09-01","current":false,"derived":true,"evidenceMineId":"4407220","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0100767|2016-03-31|C15863|2009-05-08|97276"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0166033","name":"Jewell Valley Mining LLC"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2019-09-02","validTo":"2020-09-28","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0166033|2019-09-02|2020-09-28"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2019-09-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0098293|2019-09-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"operator","id":"0166033","name":"Jewell Valley Mining LLC"},"validFrom":"2019-09-02","validTo":"2020-09-28","current":false,"derived":true,"evidenceMineId":"4407220","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0166033|2019-09-02|0098293|2019-09-02|16174"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0172933","name":"Mountaineer Metallurgical Holdings LLC"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2020-09-29","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0172933|2020-09-29|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0157861","name":"Mark  Nelson Et Al"},"object":{"type":"mine","id":"4407220","name":"JV 17 Mine"},"validFrom":"2020-09-29","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0157861|2020-09-29|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157861","name":"Mark  Nelson Et Al"},"object":{"type":"operator","id":"0172933","name":"Mountaineer Metallurgical Holdings LLC"},"validFrom":"2020-09-29","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407220","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0172933|2020-09-29|0157861|2020-09-29|32686"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157861","name":"C6 Ventures LLC Et Al"},"object":{"type":"operator","id":"0172933","name":"Mountaineer Metallurgical Holdings LLC"},"validFrom":"2020-09-29","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407220","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407220|0172933|2020-09-29|0157861|2020-09-29|32687"}}],"coverage":{"historyRecords":7,"edgeCount":18,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":24,"firstDate":"2009-09-23","lastDate":"2020-08-11","metrics":{"daysLost":1319,"injuries":20,"fatalities":0,"recentRows":0,"restrictedDays":44,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"257171","DOCUMENT_NO":"220202260018","ACCIDENT_DT":"08/11/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"Continuous miner lost power, was lifting miner cable out of mud to check cable splices, while lifting cable out of mud, right foot sumped up and went to pull it out and twisted and felt something pop in left knee.","sourceDate":"2020-08-11"},{"SOURCE_ROW_NUMBER":"222717","DOCUMENT_NO":"220201710011","ACCIDENT_DT":"06/15/2020","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Roof fall occurred in the number 5 entry between spad 78 and 88, in a area that was mined in excess of 10 years ago. The area showed no evidence of taking weight or roof cracking prior to the fall. The fall occurred 18 crosscuts from the surface in the intake entry with the cfm excess of 250,000 exposing the roof to atmospheric weathering and temperature changes.","sourceDate":"2020-06-15"},{"SOURCE_ROW_NUMBER":"16272","DOCUMENT_NO":"220201140012","ACCIDENT_DT":"04/22/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"Employee was dragging feeder cable with ride, when EE stood up and twisted left knee.","sourceDate":"2020-04-22"},{"SOURCE_ROW_NUMBER":"37827","DOCUMENT_NO":"220200300003","ACCIDENT_DT":"01/22/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"358","NARRATIVE":"EE was helping load scoop bucket, piece of rib fell striking EE in left ankle, impact caused EE to fall.","sourceDate":"2020-01-22"},{"SOURCE_ROW_NUMBER":"179759","DOCUMENT_NO":"220200090005","ACCIDENT_DT":"01/01/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"186","NARRATIVE":"IE and another EE were throwing miner cable and waterline against rib in crosscut between #3 and #4. When slinging the cable and waterline IE felt a pain in lower back. IE worked on Jan. 3rd and 4th and did not seek medical attention until Jan. 6th.","sourceDate":"2020-01-01"},{"SOURCE_ROW_NUMBER":"12034","DOCUMENT_NO":"220190520011","ACCIDENT_DT":"02/06/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"92","NARRATIVE":"While operating mantrip, employee view was blocked by case of water. When they reached up to push it out of their way, they struck their head on the overcast of #3 belt. Employee did not seek medical attention until 02/14/2019 when they were taken off work pending MRI of their neck.","sourceDate":"2019-02-06"},{"SOURCE_ROW_NUMBER":"12033","DOCUMENT_NO":"220191190019","ACCIDENT_DT":"01/23/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"358","NARRATIVE":"Employee stepped forward and slipped on miner cable causing them to fall and twist a knee. after seeking medical treatment, they went back to work. EE has continued to have issues with the knee that has lead to lost time during each follow up with doctors. On April 4th, they underwent an ACL surgery. EE was taken off work until reevaluation on May, 7 2019.","sourceDate":"2019-01-23"},{"SOURCE_ROW_NUMBER":"132205","DOCUMENT_NO":"220183380004","ACCIDENT_DT":"11/30/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"92","NARRATIVE":"Employee was cutting left sump out of #7 head, cable pulled under the miner. Employee shut off miner and walked up to remove cable a piece of draw rock fell hitting EE on the outside of EE's left foot. Rock was approx. 3' long, 3' wide and 5\" thick. Employee was seen in the ED where x-rays revealed two broken metatarsal bones and EE received 7 stitches.","sourceDate":"2018-11-30"},{"SOURCE_ROW_NUMBER":"231358","DOCUMENT_NO":"220182260019","ACCIDENT_DT":"08/03/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EMP was cutting the flapper from the take up on M5 Drive. As ee was cutting the belt, the knife slipped cutting left hand. EMP was treated and received 6 stitches.","sourceDate":"2018-08-03"},{"SOURCE_ROW_NUMBER":"196760","DOCUMENT_NO":"220171740020","ACCIDENT_DT":"06/14/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE was resetting miner breaker turned to walk away & stepped on a nail approximately 3\" long, penetrating about 2\" into right foot. EE went to ER was on crutches, foot swollen, red, & tingling. EE followed up with doctor & returned to work full duty with no restrictions on the next scheduled workday (06/21/2017). EE missed two scheduled workdays.","sourceDate":"2017-06-14"},{"SOURCE_ROW_NUMBER":"37828","DOCUMENT_NO":"220163570030","ACCIDENT_DT":"12/17/2016","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting conduit off imer cable, holding cable in left hand, cutting away with right hand. When knife blade slipped cutting employees left palm. Employee received 3 stitches in the ER.","sourceDate":"2016-12-17"},{"SOURCE_ROW_NUMBER":"80776","DOCUMENT_NO":"220162070020","ACCIDENT_DT":"07/12/2016","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EE pulled shuttle car underneath the miner conveyor boom to begin loading. During loading, apparently a rock stopped the conveyor, resulting in the failure of the boom jack and sending several parts flying through the air, most landing on the shuttle car near the operator's deck.  When the jack failed, the pin flew through the air, striking EE on right Knee Cap.","sourceDate":"2016-07-12"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2026-08-13","lastDate":"2026-08-13","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1345,"firstDate":"2009-06-09","lastDate":"2025-08-22","metrics":{"ss":374,"delinquent":1001,"recentRows":1,"paidPenalty":499204.49,"proposedPenalty":1056591,"currentAssessment":758381.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2913923","VIOLATION_NO":"9270511","ISSUE_DT":"08/22/2025","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"714.00","CURRENT_ASSESSMENT_AMT":"714.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2025-08-22"},{"SOURCE_ROW_NUMBER":"1402656","VIOLATION_NO":"8203790","ISSUE_DT":"09/01/2020","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"1402655","VIOLATION_NO":"8203789","ISSUE_DT":"09/01/2020","CFR_STANDARD_CD":"75.364(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"1402654","VIOLATION_NO":"8203788","ISSUE_DT":"09/01/2020","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"1402664","VIOLATION_NO":"9210101","ISSUE_DT":"08/20/2020","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-08-20"},{"SOURCE_ROW_NUMBER":"1402663","VIOLATION_NO":"9210100","ISSUE_DT":"08/19/2020","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"1402662","VIOLATION_NO":"9210099","ISSUE_DT":"08/19/2020","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"1402661","VIOLATION_NO":"9210098","ISSUE_DT":"08/18/2020","CFR_STANDARD_CD":"75.1714-3(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-08-18"},{"SOURCE_ROW_NUMBER":"1402660","VIOLATION_NO":"9210097","ISSUE_DT":"08/17/2020","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"351.00","CURRENT_ASSESSMENT_AMT":"351.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-08-17"},{"SOURCE_ROW_NUMBER":"1402659","VIOLATION_NO":"9210096","ISSUE_DT":"08/10/2020","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-08-10"},{"SOURCE_ROW_NUMBER":"1402658","VIOLATION_NO":"9210089","ISSUE_DT":"07/09/2020","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-07-09"},{"SOURCE_ROW_NUMBER":"1402657","VIOLATION_NO":"9210088","ISSUE_DT":"07/08/2020","CFR_STANDARD_CD":"75.807","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"123.00","CURRENT_ASSESSMENT_AMT":"123.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2020-07-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":541,"firstDate":"2012-02-15","lastDate":"2020-11-28","metrics":{"appeals":0,"decisions":541,"recentRows":0,"decisionPenalty":500235.7,"originalPenalty":800744},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"405931","VIOLATION_NO":"7324732","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"264.00","DECISION_PENALTY_AMT":"264.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"405380","VIOLATION_NO":"9097642","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"138.00","DECISION_PENALTY_AMT":"138.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"405379","VIOLATION_NO":"9097621","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"118.00","DECISION_PENALTY_AMT":"118.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"405378","VIOLATION_NO":"7324729","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"1118.00","DECISION_PENALTY_AMT":"1118.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"404513","VIOLATION_NO":"7324734","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"128.00","DECISION_PENALTY_AMT":"128.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"404512","VIOLATION_NO":"7324727","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"336.00","DECISION_PENALTY_AMT":"336.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"134755","VIOLATION_NO":"7324733","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"128.00","DECISION_PENALTY_AMT":"128.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"134754","VIOLATION_NO":"7324731","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"1031.00","DECISION_PENALTY_AMT":"1031.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"134753","VIOLATION_NO":"7324730","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"336.00","DECISION_PENALTY_AMT":"336.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"134686","VIOLATION_NO":"7324728","DOCKET_NO":"VA 2018-0162","DECISION_DT":"11/28/2020","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"225.00","DECISION_PENALTY_AMT":"225.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2020-11-28"},{"SOURCE_ROW_NUMBER":"414731","VIOLATION_NO":"9874051","DOCKET_NO":"VA 2019-0138","DECISION_DT":"10/17/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"135.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2019-10-17"},{"SOURCE_ROW_NUMBER":"414507","VIOLATION_NO":"9874052","DOCKET_NO":"VA 2019-0138","DECISION_DT":"10/17/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"768.00","DECISION_PENALTY_AMT":"384.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2019-10-17"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":2080,"firstDate":"2010-08-11","lastDate":"2076-07-11","metrics":{"recentRows":1,"cpdmSamples":1076,"voidSamples":667,"validSamples":1413,"maxConcentration":52.992,"concentrationTotal":920.371},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"51522","CASS_NUM":"51140679","SMP_TAKEN_DT":"7/11/2076","CONC":"1.158","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2076-07-11"},{"SOURCE_ROW_NUMBER":"14247","CASS_NUM":"58346630","SMP_TAKEN_DT":"9/9/2020","CONC":".034","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CLERK/TIMEKEEPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2020-09-09"},{"SOURCE_ROW_NUMBER":"2981360","SMP_TAKEN_DT":"9/8/2020","CONC":".016","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-09-08"},{"SOURCE_ROW_NUMBER":"2128792","SMP_TAKEN_DT":"9/8/2020","CONC":".006","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-09-08"},{"SOURCE_ROW_NUMBER":"2215105","SMP_TAKEN_DT":"9/3/2020","CONC":".265","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-09-03"},{"SOURCE_ROW_NUMBER":"1703718","SMP_TAKEN_DT":"9/3/2020","CONC":".05","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-09-03"},{"SOURCE_ROW_NUMBER":"2215340","SMP_TAKEN_DT":"9/2/2020","CONC":".046","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-09-02"},{"SOURCE_ROW_NUMBER":"2214915","SMP_TAKEN_DT":"9/1/2020","CONC":".067","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"1703538","SMP_TAKEN_DT":"9/1/2020","CONC":".544","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"2896986","SMP_TAKEN_DT":"8/31/2020","CONC":".045","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-08-31"},{"SOURCE_ROW_NUMBER":"2811648","SMP_TAKEN_DT":"8/31/2020","CONC":".23","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-08-31"},{"SOURCE_ROW_NUMBER":"2812447","SMP_TAKEN_DT":"8/27/2020","CONC":".017","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2020-08-27"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":13,"firstDate":"2011-08-11","lastDate":"2020-09-15","metrics":{"linkedIssuances":13},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":541,"firstDate":"2009-08-26","lastDate":"2019-05-01","metrics":{"decisions":541,"ssChanged":106,"recentRows":0,"decisionPenalty":500235.7,"proposedPenalty":800744},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"387658","CITATION_NO":"9874052","CITATION_ISSUE_DT":"05/01/2019","DOCKET_NO":"VA 2019-0138","DECISION_DT":"10/17/2019","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"768.00","DECISION_PENALTY_AMT":"384.00","sourceDate":"2019-05-01"},{"SOURCE_ROW_NUMBER":"274387","CITATION_NO":"4579258","CITATION_ISSUE_DT":"05/01/2019","DOCKET_NO":"VA 2019-0138","DECISION_DT":"10/17/2019","CFR_STANDARD_CODE":"70.209(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"115.00","sourceDate":"2019-05-01"},{"SOURCE_ROW_NUMBER":"104932","CITATION_NO":"9874051","CITATION_ISSUE_DT":"05/01/2019","DOCKET_NO":"VA 2019-0138","DECISION_DT":"10/17/2019","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"135.00","sourceDate":"2019-05-01"},{"SOURCE_ROW_NUMBER":"444663","CITATION_NO":"9874049","CITATION_ISSUE_DT":"04/10/2019","DOCKET_NO":"VA 2019-0138","DECISION_DT":"10/17/2019","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"558.00","DECISION_PENALTY_AMT":"279.00","sourceDate":"2019-04-10"},{"SOURCE_ROW_NUMBER":"44088","CITATION_NO":"9874050","CITATION_ISSUE_DT":"04/10/2019","DOCKET_NO":"VA 2019-0139","DECISION_DT":"08/30/2019","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1380.00","DECISION_PENALTY_AMT":"1380.00","sourceDate":"2019-04-10"},{"SOURCE_ROW_NUMBER":"323865","CITATION_NO":"8202933","CITATION_ISSUE_DT":"03/12/2019","DOCKET_NO":"VA 2019-0124","DECISION_DT":"08/19/2019","CFR_STANDARD_CODE":"75.1108(c)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","sourceDate":"2019-03-12"},{"SOURCE_ROW_NUMBER":"270163","CITATION_NO":"8202934","CITATION_ISSUE_DT":"03/12/2019","DOCKET_NO":"VA 2019-0124","DECISION_DT":"08/19/2019","CFR_STANDARD_CODE":"75.1108(c)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","sourceDate":"2019-03-12"},{"SOURCE_ROW_NUMBER":"269910","CITATION_NO":"8202935","CITATION_ISSUE_DT":"03/12/2019","DOCKET_NO":"VA 2019-0124","DECISION_DT":"08/19/2019","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2006.00","DECISION_PENALTY_AMT":"2006.00","sourceDate":"2019-03-12"},{"SOURCE_ROW_NUMBER":"441790","CITATION_NO":"8202932","CITATION_ISSUE_DT":"03/08/2019","DOCKET_NO":"VA 2019-0116","DECISION_DT":"08/19/2019","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"181.00","DECISION_PENALTY_AMT":"181.00","sourceDate":"2019-03-08"},{"SOURCE_ROW_NUMBER":"327367","CITATION_NO":"8202930","CITATION_ISSUE_DT":"03/04/2019","DOCKET_NO":"VA 2019-0116","DECISION_DT":"08/19/2019","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5239.00","DECISION_PENALTY_AMT":"5239.00","sourceDate":"2019-03-04"},{"SOURCE_ROW_NUMBER":"214266","CITATION_NO":"8192185","CITATION_ISSUE_DT":"03/04/2019","DOCKET_NO":"VA 2019-0116","DECISION_DT":"08/19/2019","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"344.00","DECISION_PENALTY_AMT":"344.00","sourceDate":"2019-03-04"},{"SOURCE_ROW_NUMBER":"270801","CITATION_NO":"4579253","CITATION_ISSUE_DT":"02/27/2019","DOCKET_NO":"VA 2019-0116","DECISION_DT":"08/19/2019","CFR_STANDARD_CODE":"70.208(a)(2)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"319.00","DECISION_PENALTY_AMT":"319.00","sourceDate":"2019-02-27"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1638,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":14,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":411,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":14,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"2008-04-08","lastDate":"2020-09-29","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":130,"firstDate":"2009-05-29","lastDate":"2026-07-14","metrics":{"inspectors":386,"recentRows":12,"onSiteHours":7883.5,"inspectionHours":12684.5,"inspectionSamples":1501},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"858813","EVENT_NO":"F023545","INSPECTION_BEGIN_DT":"07/14/2026","INSPECTION_END_DT":"07/14/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2026-07-14"},{"SOURCE_ROW_NUMBER":"802383","EVENT_NO":"4198925","INSPECTION_BEGIN_DT":"04/15/2026","INSPECTION_END_DT":"05/19/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2026-04-15"},{"SOURCE_ROW_NUMBER":"759364","EVENT_NO":"F02352C","INSPECTION_BEGIN_DT":"02/19/2026","INSPECTION_END_DT":"02/24/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2026-02-19"},{"SOURCE_ROW_NUMBER":"189215","EVENT_NO":"F002517","INSPECTION_BEGIN_DT":"12/11/2025","INSPECTION_END_DT":"12/11/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2025-12-11"},{"SOURCE_ROW_NUMBER":"813200","EVENT_NO":"F004F7D","INSPECTION_BEGIN_DT":"08/12/2025","INSPECTION_END_DT":"09/03/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.25","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2025-08-12"},{"SOURCE_ROW_NUMBER":"170564","EVENT_NO":"F004F73","INSPECTION_BEGIN_DT":"05/01/2025","INSPECTION_END_DT":"05/01/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2025-05-01"},{"SOURCE_ROW_NUMBER":"538577","EVENT_NO":"F010BFC","INSPECTION_BEGIN_DT":"01/23/2025","INSPECTION_END_DT":"01/23/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2025-01-23"},{"SOURCE_ROW_NUMBER":"819408","EVENT_NO":"4132527","INSPECTION_BEGIN_DT":"11/14/2024","INSPECTION_END_DT":"11/14/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2024-11-14"},{"SOURCE_ROW_NUMBER":"370288","EVENT_NO":"4135625","INSPECTION_BEGIN_DT":"09/23/2024","INSPECTION_END_DT":"09/23/2024","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-09-23"},{"SOURCE_ROW_NUMBER":"551679","EVENT_NO":"4135614","INSPECTION_BEGIN_DT":"04/10/2024","INSPECTION_END_DT":"04/10/2024","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-04-10"},{"SOURCE_ROW_NUMBER":"461759","EVENT_NO":"4135603","INSPECTION_BEGIN_DT":"02/21/2024","INSPECTION_END_DT":"02/21/2024","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".75","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-02-21"},{"SOURCE_ROW_NUMBER":"1057539","EVENT_NO":"4426096","INSPECTION_BEGIN_DT":"01/04/2021","INSPECTION_END_DT":"02/01/2021","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2021-01-04"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":128,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2021-Q3":{"hours":806,"employees":5,"production":0},"2021-Q2":{"hours":822,"employees":4,"production":0},"2021-Q1":{"hours":1798,"employees":4,"production":0},"2020-Q4":{"hours":2101,"employees":6,"production":0},"2020-Q3":{"hours":13468,"employees":34,"production":12527},"2020-Q2":{"hours":27602,"employees":39,"production":39073},"2020-Q1":{"hours":28519,"employees":43,"production":26673},"2019-Q4":{"hours":16109,"employees":30,"production":3193},"2019-Q3":{"hours":767,"employees":4,"production":0},"2019-Q1":{"hours":38884,"employees":79,"production":33765},"2018-Q4":{"hours":39004,"employees":91,"production":43122},"2018-Q3":{"hours":54373,"employees":95,"production":37686}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012":{"hours":176189,"employees":72,"production":209196},"2013":{"hours":183799,"employees":85,"production":230717},"2014":{"hours":53012,"employees":22,"production":97145},"2015":{"hours":67070,"employees":28,"production":146269},"2016":{"hours":54071,"employees":26,"production":85323},"2017":{"hours":96199,"employees":34,"production":107220},"2018":{"hours":169921,"employees":80,"production":167534},"2019":{"hours":55760,"employees":38,"production":36958},"2020":{"hours":71690,"employees":31,"production":78273},"2021":{"hours":3426,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":148,"firstDate":"2010-09-15","lastDate":"2020-09-09","metrics":{"recentRows":0,"doseOver100":27,"actDoseTotal":10389,"pelDoseTotal":7884},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"211244","EVENT_NO":"4421941","SURVEY_DATE":"09/09/2020","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2020-09-09"},{"SOURCE_ROW_NUMBER":"211198","EVENT_NO":"4419156","SURVEY_DATE":"05/14/2020","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"10","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2020-05-14"},{"SOURCE_ROW_NUMBER":"211197","EVENT_NO":"4419156","SURVEY_DATE":"05/14/2020","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"20","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2020-05-14"},{"SOURCE_ROW_NUMBER":"211243","EVENT_NO":"4421937","SURVEY_DATE":"03/24/2020","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"58","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2020-03-24"},{"SOURCE_ROW_NUMBER":"211242","EVENT_NO":"4421937","SURVEY_DATE":"03/24/2020","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"95","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2020-03-24"},{"SOURCE_ROW_NUMBER":"211241","EVENT_NO":"4421937","SURVEY_DATE":"03/24/2020","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"62","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2020-03-24"},{"SOURCE_ROW_NUMBER":"211240","EVENT_NO":"4421937","SURVEY_DATE":"03/24/2020","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"106","PEL_DOSE_90":"90","SURVEY_TYPE":"I","sourceDate":"2020-03-24"},{"SOURCE_ROW_NUMBER":"211239","EVENT_NO":"4421937","SURVEY_DATE":"03/24/2020","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"58","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2020-03-24"},{"SOURCE_ROW_NUMBER":"211229","EVENT_NO":"4421696","SURVEY_DATE":"05/14/2019","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2019-05-14"},{"SOURCE_ROW_NUMBER":"211238","EVENT_NO":"4421696","SURVEY_DATE":"05/07/2019","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"64","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2019-05-07"},{"SOURCE_ROW_NUMBER":"211237","EVENT_NO":"4421696","SURVEY_DATE":"05/07/2019","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"22","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2019-05-07"},{"SOURCE_ROW_NUMBER":"211236","EVENT_NO":"4421696","SURVEY_DATE":"05/07/2019","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"35","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2019-05-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":80,"firstDate":"2010-09-13","lastDate":"2020-08-25","metrics":{"recentRows":0,"voidSamples":8,"maxQuartzPct":16.9,"validSamples":72,"quartzPctTotal":501.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"152786","CASSETTE_NO":"58346541","SAMPLE_DT":"08/25/2020","QUARTZ_PCT":"09.4","QUARTZ_MICROGRAMS":"23","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-08-25"},{"SOURCE_ROW_NUMBER":"36327","CASSETTE_NO":"58346657","SAMPLE_DT":"08/25/2020","QUARTZ_PCT":"06.3","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-08-25"},{"SOURCE_ROW_NUMBER":"138380","CASSETTE_NO":"58346883","SAMPLE_DT":"04/15/2020","QUARTZ_PCT":"05.2","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-04-15"},{"SOURCE_ROW_NUMBER":"136611","CASSETTE_NO":"58347079","SAMPLE_DT":"04/15/2020","QUARTZ_PCT":"04.0","QUARTZ_MICROGRAMS":"52","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-04-15"},{"SOURCE_ROW_NUMBER":"121879","CASSETTE_NO":"58347045","SAMPLE_DT":"03/16/2020","QUARTZ_PCT":"06.9","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-03-16"},{"SOURCE_ROW_NUMBER":"19068","CASSETTE_NO":"58347292","SAMPLE_DT":"03/16/2020","QUARTZ_PCT":"06.3","QUARTZ_MICROGRAMS":"39","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-03-16"},{"SOURCE_ROW_NUMBER":"150378","CASSETTE_NO":"58279631","SAMPLE_DT":"04/02/2019","QUARTZ_PCT":"05.2","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-04-02"},{"SOURCE_ROW_NUMBER":"114781","CASSETTE_NO":"58279503","SAMPLE_DT":"04/02/2019","QUARTZ_PCT":"06.3","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-04-02"},{"SOURCE_ROW_NUMBER":"71417","CASSETTE_NO":"58279504","SAMPLE_DT":"04/02/2019","QUARTZ_PCT":"04.2","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-04-02"},{"SOURCE_ROW_NUMBER":"35082","CASSETTE_NO":"58279693","SAMPLE_DT":"04/02/2019","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-04-02"},{"SOURCE_ROW_NUMBER":"32149","CASSETTE_NO":"58279510","SAMPLE_DT":"04/02/2019","QUARTZ_PCT":"02.4","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-04-02"},{"SOURCE_ROW_NUMBER":"163988","CASSETTE_NO":"58279578","SAMPLE_DT":"03/06/2019","QUARTZ_PCT":"04.7","QUARTZ_MICROGRAMS":"37","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-03-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1371,"firstDate":"2009-06-09","lastDate":"2025-09-03","metrics":{"ss":374,"amountDue":758381.7,"contested":3,"amountPaid":499204.49,"recentRows":2,"section104d":8,"unterminated":3,"proposedPenalty":1056591},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2432356","VIOLATION_NO":"9270514","VIOLATION_ISSUE_DT":"09/03/2025","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"02/24/2026","CONTESTED_IND":"N","sourceDate":"2025-09-03"},{"SOURCE_ROW_NUMBER":"2432355","VIOLATION_NO":"9270511","VIOLATION_ISSUE_DT":"08/22/2025","SIG_SUB":"Y","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","PROPOSED_PENALTY":"714","AMOUNT_DUE":"714","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2025-08-22"},{"SOURCE_ROW_NUMBER":"2432228","VIOLATION_NO":"8203790","VIOLATION_ISSUE_DT":"09/01/2020","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/15/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"2432227","VIOLATION_NO":"8203789","VIOLATION_ISSUE_DT":"09/01/2020","SIG_SUB":"N","PART_SECTION":"75.364(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/01/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"2432226","VIOLATION_NO":"8203788","VIOLATION_ISSUE_DT":"09/01/2020","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/01/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"2432236","VIOLATION_NO":"9210101","VIOLATION_ISSUE_DT":"08/20/2020","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-08-20"},{"SOURCE_ROW_NUMBER":"2432235","VIOLATION_NO":"9210100","VIOLATION_ISSUE_DT":"08/19/2020","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/19/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"2432234","VIOLATION_NO":"9210099","VIOLATION_ISSUE_DT":"08/19/2020","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/19/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-08-19"},{"SOURCE_ROW_NUMBER":"2432233","VIOLATION_NO":"9210098","VIOLATION_ISSUE_DT":"08/18/2020","SIG_SUB":"N","PART_SECTION":"75.1714-3(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/18/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-08-18"},{"SOURCE_ROW_NUMBER":"2432232","VIOLATION_NO":"9210097","VIOLATION_ISSUE_DT":"08/17/2020","SIG_SUB":"Y","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/19/2020","PROPOSED_PENALTY":"351","AMOUNT_DUE":"351","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-08-17"},{"SOURCE_ROW_NUMBER":"2432231","VIOLATION_NO":"9210096","VIOLATION_ISSUE_DT":"08/10/2020","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/10/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-08-10"},{"SOURCE_ROW_NUMBER":"2432230","VIOLATION_NO":"9210089","VIOLATION_ISSUE_DT":"07/09/2020","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2020","PROPOSED_PENALTY":"123","AMOUNT_DUE":"123","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2020-07-09"}]}],"safety":{"href":"/api/v1/mines/4407220/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4407220/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4407220","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}