{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4407155","name":"Centurion","status":"Abandoned","status_date":"2006-06-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Pound","operator_id":"0071704","operator_name":"Pound River Properties, LLC.","controller_id":"0060049","controller_name":"(Landon) Keller  Smith; Karl  Singer","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.106816,"longitude":-82.609136},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":366},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4407155","name":"Centurion"},"operator":{"type":"operator","id":"0071704","name":"Pound River Properties, LLC."},"controller":{"type":"controller","id":"0060049","name":"(Landon) Keller  Smith; Karl  Singer"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0065323","name":"Lo-Kol Inc"},"object":{"type":"mine","id":"4407155","name":"Centurion"},"validFrom":"2005-11-01","validTo":"2006-03-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407155|0065323|2005-11-01|2006-03-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03007","name":"Billy Ray  Dotson"},"object":{"type":"mine","id":"4407155","name":"Centurion"},"validFrom":"2005-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407155|C03007|2005-11-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03007","name":"Billy Ray  Dotson"},"object":{"type":"operator","id":"0065323","name":"Lo-Kol Inc"},"validFrom":"2005-11-01","validTo":"2006-03-31","current":false,"derived":true,"evidenceMineId":"4407155","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407155|0065323|2005-11-01|C03007|2005-11-01|61616"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0071704","name":"Pound River Properties, LLC."},"object":{"type":"mine","id":"4407155","name":"Centurion"},"validFrom":"2006-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407155|0071704|2006-04-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0060049","name":"(Landon) Keller  Smith et al"},"object":{"type":"mine","id":"4407155","name":"Centurion"},"validFrom":"2006-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407155|0060049|2006-04-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0060049","name":"(Landon) Keller  Smith et al"},"object":{"type":"operator","id":"0071704","name":"Pound River Properties, LLC."},"validFrom":"2006-04-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407155","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407155|0071704|2006-04-01|0060049|2006-04-01|8005"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0060049","name":"Karl  Singer et al"},"object":{"type":"operator","id":"0071704","name":"Pound River Properties, LLC."},"validFrom":"2006-04-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407155","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407155|0071704|2006-04-01|0060049|2006-04-01|8006"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2005-12-08","lastDate":"2006-04-16","metrics":{"daysLost":0,"injuries":4,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"12024","DOCUMENT_NO":"220061170026","ACCIDENT_DT":"04/16/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was using a pry bar to remove shims from the miner. The bar slipped and EE fell & hit the mine with his shoulder.","sourceDate":"2006-04-16"},{"SOURCE_ROW_NUMBER":"119320","DOCUMENT_NO":"220060550049","ACCIDENT_DT":"02/17/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Assayer, Geologist, Metallurgist, Engineer, Engineer management","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Remove mine cable hit roof bolt","sourceDate":"2006-02-17"},{"SOURCE_ROW_NUMBER":"93527","DOCUMENT_NO":"220060550050","ACCIDENT_DT":"02/16/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Mash finger with pinner steel","sourceDate":"2006-02-16"},{"SOURCE_ROW_NUMBER":"171177","DOCUMENT_NO":"220053560033","ACCIDENT_DT":"12/08/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Head of pinner mash toe","sourceDate":"2005-12-08"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-06-30","lastDate":"2006-06-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":38,"firstDate":"2005-12-14","lastDate":"2006-05-25","metrics":{"ss":16,"delinquent":38,"recentRows":0,"paidPenalty":2872,"proposedPenalty":2872,"currentAssessment":2872},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"927029","VIOLATION_NO":"7310735","ISSUE_DT":"05/25/2006","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-25"},{"SOURCE_ROW_NUMBER":"927028","VIOLATION_NO":"7310734","ISSUE_DT":"05/22/2006","CFR_STANDARD_CD":"49.2(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"221.00","CURRENT_ASSESSMENT_AMT":"221.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-22"},{"SOURCE_ROW_NUMBER":"927027","VIOLATION_NO":"7310733","ISSUE_DT":"05/22/2006","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-22"},{"SOURCE_ROW_NUMBER":"927030","VIOLATION_NO":"7345348","ISSUE_DT":"05/03/2006","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-03"},{"SOURCE_ROW_NUMBER":"927026","VIOLATION_NO":"7310727","ISSUE_DT":"04/20/2006","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-20"},{"SOURCE_ROW_NUMBER":"927025","VIOLATION_NO":"7310726","ISSUE_DT":"04/19/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"927024","VIOLATION_NO":"7310725","ISSUE_DT":"04/19/2006","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"927023","VIOLATION_NO":"7310724","ISSUE_DT":"04/19/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"927022","VIOLATION_NO":"7310723","ISSUE_DT":"04/19/2006","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"927021","VIOLATION_NO":"7310722","ISSUE_DT":"04/18/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"927020","VIOLATION_NO":"7310721","ISSUE_DT":"04/18/2006","CFR_STANDARD_CD":"75.523-1(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"927019","VIOLATION_NO":"7310720","ISSUE_DT":"04/18/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-18"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":16,"firstDate":"2006-01-20","lastDate":"2006-03-16","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":16,"maxConcentration":1.923,"concentrationTotal":7.745},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1649790","CASS_NUM":"57631355","SMP_TAKEN_DT":"3/16/2006","CONC":".178","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"916865","CASS_NUM":"57631284","SMP_TAKEN_DT":"3/16/2006","CONC":".202","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"827041","CASS_NUM":"57631163","SMP_TAKEN_DT":"3/16/2006","CONC":".018","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"480496","CASS_NUM":"57631285","SMP_TAKEN_DT":"3/16/2006","CONC":".109","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"359329","CASS_NUM":"57631366","SMP_TAKEN_DT":"3/16/2006","CONC":".516","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"257445","CASS_NUM":"57631259","SMP_TAKEN_DT":"3/16/2006","CONC":".409","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"219336","CASS_NUM":"50822451","SMP_TAKEN_DT":"3/10/2006","CONC":"1.923","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-10"},{"SOURCE_ROW_NUMBER":"139950","CASS_NUM":"50822437","SMP_TAKEN_DT":"3/9/2006","CONC":".654","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-09"},{"SOURCE_ROW_NUMBER":"322739","CASS_NUM":"50822496","SMP_TAKEN_DT":"3/8/2006","CONC":".043","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-08"},{"SOURCE_ROW_NUMBER":"727020","CASS_NUM":"50822453","SMP_TAKEN_DT":"3/7/2006","CONC":"1.49","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"1320745","CASS_NUM":"50822447","SMP_TAKEN_DT":"3/6/2006","CONC":".319","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-06"},{"SOURCE_ROW_NUMBER":"1074030","CASS_NUM":"50822440","SMP_TAKEN_DT":"1/30/2006","CONC":".051","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-01-30"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":203,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":48,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2005-11-01","lastDate":"2006-04-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":3,"firstDate":"2005-11-22","lastDate":"2006-04-03","metrics":{"inspectors":10,"recentRows":0,"onSiteHours":155.5,"inspectionHours":248,"inspectionSamples":10},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1022341","EVENT_NO":"4157009","INSPECTION_BEGIN_DT":"04/03/2006","INSPECTION_END_DT":"06/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"85.5","SUM_TOTAL_ON_SITE_HOURS":"53.5","sourceDate":"2006-04-03"},{"SOURCE_ROW_NUMBER":"637874","EVENT_NO":"4156990","INSPECTION_BEGIN_DT":"01/03/2006","INSPECTION_END_DT":"03/23/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"96.25","SUM_TOTAL_ON_SITE_HOURS":"61.5","sourceDate":"2006-01-03"},{"SOURCE_ROW_NUMBER":"684504","EVENT_NO":"4156979","INSPECTION_BEGIN_DT":"11/22/2005","INSPECTION_END_DT":"12/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"66.25","SUM_TOTAL_ON_SITE_HOURS":"40.5","sourceDate":"2005-11-22"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q3":{"hours":0,"employees":0,"production":0},"2006-Q2":{"hours":1443,"employees":3,"production":11471},"2006-Q1":{"hours":10,"employees":1,"production":0},"2005-Q4":{"hours":10,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":10,"employees":1,"production":0},"2006":{"hours":1453,"employees":3,"production":11471}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":1,"firstDate":"2006-03-16","lastDate":"2006-03-16","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":8.6,"validSamples":1,"quartzPctTotal":8.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"162226","CASSETTE_NO":"57631366","SAMPLE_DT":"03/16/2006","QUARTZ_PCT":"08.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-03-16"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":39,"firstDate":"2005-12-14","lastDate":"2006-05-30","metrics":{"ss":16,"amountDue":2872,"contested":0,"amountPaid":2872,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":2872},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2422118","VIOLATION_NO":"7310736","VIOLATION_ISSUE_DT":"05/30/2006","PART_SECTION":"49.2(a)(2)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"06/07/2006","CONTESTED_IND":"N","sourceDate":"2006-05-30"},{"SOURCE_ROW_NUMBER":"2422117","VIOLATION_NO":"7310735","VIOLATION_ISSUE_DT":"05/25/2006","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/30/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-05-25"},{"SOURCE_ROW_NUMBER":"2422116","VIOLATION_NO":"7310734","VIOLATION_ISSUE_DT":"05/22/2006","SIG_SUB":"N","PART_SECTION":"49.2(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"221","AMOUNT_DUE":"221","AMOUNT_PAID":"221","CONTESTED_IND":"N","sourceDate":"2006-05-22"},{"SOURCE_ROW_NUMBER":"2422115","VIOLATION_NO":"7310733","VIOLATION_ISSUE_DT":"05/22/2006","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/25/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-05-22"},{"SOURCE_ROW_NUMBER":"2422119","VIOLATION_NO":"7345348","VIOLATION_ISSUE_DT":"05/03/2006","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/03/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-05-03"},{"SOURCE_ROW_NUMBER":"2422114","VIOLATION_NO":"7310727","VIOLATION_ISSUE_DT":"04/20/2006","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-04-20"},{"SOURCE_ROW_NUMBER":"2422113","VIOLATION_NO":"7310726","VIOLATION_ISSUE_DT":"04/19/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"2422112","VIOLATION_NO":"7310725","VIOLATION_ISSUE_DT":"04/19/2006","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"2422111","VIOLATION_NO":"7310724","VIOLATION_ISSUE_DT":"04/19/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"2422110","VIOLATION_NO":"7310723","VIOLATION_ISSUE_DT":"04/19/2006","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-04-19"},{"SOURCE_ROW_NUMBER":"2422109","VIOLATION_NO":"7310722","VIOLATION_ISSUE_DT":"04/18/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/18/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"2422108","VIOLATION_NO":"7310721","VIOLATION_ISSUE_DT":"04/18/2006","SIG_SUB":"Y","PART_SECTION":"75.523-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/18/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-04-18"}]}],"safety":{"href":"/api/v1/mines/4407155/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4407155/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Availability of mine rescue teams.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-49/subpart-A/section-49.2","part":"49","subchapter":"H","subpart":"A","id":"49.2","citation":"30 CFR 49.2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 49—MINE RESCUE TEAMS","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":2},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment installation requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-1","part":"75","subchapter":"O","subpart":"F","id":"75.523-1","citation":"30 CFR 75.523-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4407155","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}