{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4407138","name":"Guest Mtn. No. 5","status":"Abandoned and Sealed","status_date":"2014-05-06","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Appalachia","operator_id":"P23653","operator_name":"Mill Branch Coal Corp","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.002778,"longitude":-82.79},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2565},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"operator":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"1993-03-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|C07082|1993-03-01|2010-04-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"1996-12-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|C07082|1996-12-01|2010-04-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02535","name":"Jim D  Akers et al"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2001-12-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|C02535|2001-12-19|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0061164","name":"Commonwealth No. 3, Inc."},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2005-06-02","validTo":"2006-06-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|0061164|2005-06-02|2006-06-08"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15465","name":"Charles D  Mullins"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2005-06-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|C15465|2005-06-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15465","name":"Charles D  Mullins"},"object":{"type":"operator","id":"0061164","name":"Commonwealth No. 3, Inc."},"validFrom":"2005-06-02","validTo":"2006-06-08","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|0061164|2005-06-02|C15465|2005-06-02|95710"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050049","name":"Hubble Mining Co., LLC"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2006-06-09","validTo":"2008-04-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|0050049|2006-06-09|2008-04-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02535","name":"Jim D  Akers et al"},"object":{"type":"operator","id":"0050049","name":"Hubble Mining Co., LLC"},"validFrom":"2006-06-09","validTo":"2008-04-30","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|0050049|2006-06-09|C02535|2001-12-19|59859"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02535","name":"Harold E  Akers et al"},"object":{"type":"operator","id":"0050049","name":"Hubble Mining Co., LLC"},"validFrom":"2006-06-09","validTo":"2008-04-30","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|0050049|2006-06-09|C02535|2001-12-19|59860"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2008-05-01","validTo":"2012-12-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P22270|2008-05-01|2012-12-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2008-05-01","validTo":"2010-04-18","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P22270|2008-05-01|C07082|1993-03-01|73680"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|C02508|2010-04-19|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P22270|2008-05-01|C02508|2010-04-19|59608"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2011-06-01","validTo":"2012-12-31","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P22270|2008-05-01|0041211|2011-06-01|2310"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"object":{"type":"mine","id":"4407138","name":"Guest Mtn. No. 5"},"validFrom":"2013-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P23653|2013-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"validFrom":"2013-01-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P23653|2013-01-01|0041211|2011-06-01|2311"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"validFrom":"2013-01-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P23653|2013-01-01|C02508|2010-04-19|59609"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"validFrom":"2013-01-01","validTo":"2010-04-18","current":false,"derived":true,"evidenceMineId":"4407138","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407138|P23653|2013-01-01|C07082|1996-12-01|73715"}}],"coverage":{"historyRecords":9,"edgeCount":19,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":20,"firstDate":"2006-10-16","lastDate":"2014-03-17","metrics":{"daysLost":435,"injuries":20,"fatalities":0,"recentRows":0,"restrictedDays":192,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"12021","DOCUMENT_NO":"220140850026","ACCIDENT_DT":"03/17/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Clerk, Timekeeper, Office worker, Director of sales","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a hearing loss diagnosis on 3/17/2014 for employee.","sourceDate":"2014-03-17"},{"SOURCE_ROW_NUMBER":"127855","DOCUMENT_NO":"220140760016","ACCIDENT_DT":"03/06/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a hearing loss diagnosis for employee on 3/6/2014.","sourceDate":"2014-03-06"},{"SOURCE_ROW_NUMBER":"7690","DOCUMENT_NO":"220140760012","ACCIDENT_DT":"03/06/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a CWP diagnosis for employee on 3/6/2014.","sourceDate":"2014-03-06"},{"SOURCE_ROW_NUMBER":"218436","DOCUMENT_NO":"220140300030","ACCIDENT_DT":"01/24/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Clerk, Timekeeper, Office worker, Director of sales","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a CWP diagnosis on 1/24/2014 for employee.","sourceDate":"2014-01-24"},{"SOURCE_ROW_NUMBER":"265756","DOCUMENT_NO":"220113500030","ACCIDENT_DT":"12/16/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Drill steel was hung in the drill chuck, employee struck drill steel with wrench and it came back striking employee above the left eye causing a laceration.","sourceDate":"2011-12-16"},{"SOURCE_ROW_NUMBER":"63445","DOCUMENT_NO":"220112360010","ACCIDENT_DT":"08/15/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The Lo Trac operator was checking the fluids on his equipment. When the operator raised the engine hatch to check the fluids, he secured the hatch with a rope hanger. The rope hanger came loose causing the hatch to fall on the operator's left hand resulting in a fractured thumb.","sourceDate":"2011-08-15"},{"SOURCE_ROW_NUMBER":"218435","DOCUMENT_NO":"220112150029","ACCIDENT_DT":"07/30/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"Employee was beating foot shaft off miner. Piece of steel punctured left arm and lodged in it.","sourceDate":"2011-07-30"},{"SOURCE_ROW_NUMBER":"158214","DOCUMENT_NO":"220111080032","ACCIDENT_DT":"04/12/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"126","NARRATIVE":"The individual was trying to pull a piece of ventilation curtain on a mud hole. He was pulling with both hands when his left hand slipped and caused him to strain his right shoulder.","sourceDate":"2011-04-12"},{"SOURCE_ROW_NUMBER":"42042","DOCUMENT_NO":"220110540032","ACCIDENT_DT":"02/21/2011","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"32","NARRATIVE":"The employee was pushing a rock out of the way with the stab jack on the roof bolter. The rock either broke or the stab jack slipped over top of the rock, causing the drill head to move forward quickly catching his left thumb between the drill steel and the canopy post.","sourceDate":"2011-02-21"},{"SOURCE_ROW_NUMBER":"149651","DOCUMENT_NO":"220110530061","ACCIDENT_DT":"02/16/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The individual was putting an end on an extension cord and cut his thumb resulting in a laceration that required stitches. This is a medical only report with no lost or restricted work days.","sourceDate":"2011-02-16"},{"SOURCE_ROW_NUMBER":"127854","DOCUMENT_NO":"220110100027","ACCIDENT_DT":"12/29/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While the individual was tightening the wheel on the shuttle car, the ratchet slipped causing him to lose balance and fall hitting his mouth on the fender resulting in two chipped teeth. There were no lost or restricted days and he has not sought treatment.","sourceDate":"2010-12-29"},{"SOURCE_ROW_NUMBER":"16262","DOCUMENT_NO":"220103260052","ACCIDENT_DT":"11/10/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"159","NARRATIVE":"The individual pulled a pallet off the Lo Trac fork lift and mashed the ring finger on his left hand. He developed staff infection and was hospitalized.","sourceDate":"2010-11-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-05-06","lastDate":"2014-05-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":502,"firstDate":"2006-06-22","lastDate":"2013-12-10","metrics":{"ss":131,"delinquent":502,"recentRows":0,"paidPenalty":190400,"proposedPenalty":240522,"currentAssessment":190400},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1355285","VIOLATION_NO":"8208654","ISSUE_DT":"12/10/2013","CFR_STANDARD_CD":"75.1714-7(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-12-10"},{"SOURCE_ROW_NUMBER":"1355284","VIOLATION_NO":"8208653","ISSUE_DT":"12/10/2013","CFR_STANDARD_CD":"75.380(d)(7)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-12-10"},{"SOURCE_ROW_NUMBER":"1366726","VIOLATION_NO":"8208702","ISSUE_DT":"09/06/2013","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"1366725","VIOLATION_NO":"8208701","ISSUE_DT":"09/06/2013","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"1366724","VIOLATION_NO":"8202000","ISSUE_DT":"09/06/2013","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"1366723","VIOLATION_NO":"8201992","ISSUE_DT":"08/13/2013","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1366722","VIOLATION_NO":"8201991","ISSUE_DT":"08/13/2013","CFR_STANDARD_CD":"75.204(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1366721","VIOLATION_NO":"8201990","ISSUE_DT":"08/05/2013","CFR_STANDARD_CD":"48.11","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"372.00","CURRENT_ASSESSMENT_AMT":"200.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-05"},{"SOURCE_ROW_NUMBER":"1366720","VIOLATION_NO":"8201986","ISSUE_DT":"07/26/2013","CFR_STANDARD_CD":"75.206(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-26"},{"SOURCE_ROW_NUMBER":"1366719","VIOLATION_NO":"8201985","ISSUE_DT":"07/26/2013","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"400.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-26"},{"SOURCE_ROW_NUMBER":"1366718","VIOLATION_NO":"8201984","ISSUE_DT":"07/24/2013","CFR_STANDARD_CD":"75.1505(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"102.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"1366717","VIOLATION_NO":"8201983","ISSUE_DT":"07/24/2013","CFR_STANDARD_CD":"75.333(c)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"275.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":188,"firstDate":"2009-07-08","lastDate":"2014-08-27","metrics":{"appeals":0,"decisions":188,"recentRows":0,"decisionPenalty":147997,"originalPenalty":200951},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"350857","VIOLATION_NO":"8201990","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"372.00","DECISION_PENALTY_AMT":"200.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-08-27"},{"SOURCE_ROW_NUMBER":"350732","VIOLATION_NO":"8202000","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-08-27"},{"SOURCE_ROW_NUMBER":"350731","VIOLATION_NO":"8201992","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"745.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-08-27"},{"SOURCE_ROW_NUMBER":"102288","VIOLATION_NO":"8208701","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-08-27"},{"SOURCE_ROW_NUMBER":"350323","VIOLATION_NO":"8201983","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"275.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"349491","VIOLATION_NO":"8201979","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"268.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"349345","VIOLATION_NO":"8201984","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"102.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"349235","VIOLATION_NO":"8201982","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2350.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"349234","VIOLATION_NO":"8201970","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"834.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"349233","VIOLATION_NO":"8201968","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"348823","VIOLATION_NO":"8201980","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"348822","VIOLATION_NO":"8201969","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"850.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-07-31"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":511,"firstDate":"2006-07-10","lastDate":"2013-09-30","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":53,"validSamples":458,"maxConcentration":8.167,"concentrationTotal":229.257},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"36629","CASS_NUM":"51252659","SMP_TAKEN_DT":"9/30/2013","CONC":".226","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-30"},{"SOURCE_ROW_NUMBER":"1409397","CASS_NUM":"51252856","SMP_TAKEN_DT":"9/11/2013","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-11"},{"SOURCE_ROW_NUMBER":"136394","CASS_NUM":"51252636","SMP_TAKEN_DT":"9/11/2013","CONC":".326","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-11"},{"SOURCE_ROW_NUMBER":"1282587","CASS_NUM":"51236649","SMP_TAKEN_DT":"9/10/2013","CONC":".15","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-10"},{"SOURCE_ROW_NUMBER":"695688","CASS_NUM":"51252845","SMP_TAKEN_DT":"9/10/2013","CONC":".406","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-10"},{"SOURCE_ROW_NUMBER":"1416057","CASS_NUM":"51236695","SMP_TAKEN_DT":"9/9/2013","CONC":".035","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-09"},{"SOURCE_ROW_NUMBER":"1326778","CASS_NUM":"51252729","SMP_TAKEN_DT":"9/9/2013","CONC":".065","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-09"},{"SOURCE_ROW_NUMBER":"865971","CASS_NUM":"58111698","SMP_TAKEN_DT":"9/6/2013","CONC":".089","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"1644147","CASS_NUM":"51252547","SMP_TAKEN_DT":"8/20/2013","CONC":".221","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-20"},{"SOURCE_ROW_NUMBER":"1343621","CASS_NUM":"51252537","SMP_TAKEN_DT":"8/20/2013","CONC":".089","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-20"},{"SOURCE_ROW_NUMBER":"1465576","CASS_NUM":"58109805","SMP_TAKEN_DT":"7/25/2013","CONC":".073","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-25"},{"SOURCE_ROW_NUMBER":"1016834","CASS_NUM":"58109687","SMP_TAKEN_DT":"7/25/2013","CONC":".129","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-07-25"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2008-01-17","lastDate":"2010-03-04","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":188,"firstDate":"2008-03-04","lastDate":"2013-09-06","metrics":{"decisions":188,"ssChanged":20,"recentRows":0,"decisionPenalty":147997,"proposedPenalty":200951},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"149930","CITATION_NO":"8208701","CITATION_ISSUE_DT":"09/06/2013","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"149735","CITATION_NO":"8202000","CITATION_ISSUE_DT":"09/06/2013","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","CFR_STANDARD_CODE":"77.502","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"200794","CITATION_NO":"8201992","CITATION_ISSUE_DT":"08/13/2013","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"745.00","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"320120","CITATION_NO":"8201990","CITATION_ISSUE_DT":"08/05/2013","DOCKET_NO":"VA 2014-39","DECISION_DT":"08/27/2014","CFR_STANDARD_CODE":"48.11","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"372.00","DECISION_PENALTY_AMT":"200.00","sourceDate":"2013-08-05"},{"SOURCE_ROW_NUMBER":"263120","CITATION_NO":"8201985","CITATION_ISSUE_DT":"07/26/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2013-07-26"},{"SOURCE_ROW_NUMBER":"376440","CITATION_NO":"8201983","CITATION_ISSUE_DT":"07/24/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.333(c)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"275.00","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"376439","CITATION_NO":"8201977","CITATION_ISSUE_DT":"07/24/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"263417","CITATION_NO":"8201980","CITATION_ISSUE_DT":"07/24/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"257435","CITATION_NO":"8201979","CITATION_ISSUE_DT":"07/24/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"268.00","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"206935","CITATION_NO":"8201984","CITATION_ISSUE_DT":"07/24/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.1505(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"102.00","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"37291","CITATION_NO":"8201982","CITATION_ISSUE_DT":"07/24/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.380(d)(7)(vi)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2350.00","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"206867","CITATION_NO":"8201970","CITATION_ISSUE_DT":"07/11/2013","DOCKET_NO":"VA 2013-550","DECISION_DT":"07/31/2014","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"834.00","sourceDate":"2013-07-11"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":245,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":44,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":9,"firstDate":"2005-06-02","lastDate":"2013-01-01","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":6},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":111,"firstDate":"2005-08-08","lastDate":"2014-05-06","metrics":{"inspectors":183,"recentRows":0,"onSiteHours":2817.75,"inspectionHours":4557.75,"inspectionSamples":593},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"829555","EVENT_NO":"4408450","INSPECTION_BEGIN_DT":"05/06/2014","INSPECTION_END_DT":"05/06/2014","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"2.75","sourceDate":"2014-05-06"},{"SOURCE_ROW_NUMBER":"883878","EVENT_NO":"4415840","INSPECTION_BEGIN_DT":"01/14/2014","INSPECTION_END_DT":"01/14/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2014-01-14"},{"SOURCE_ROW_NUMBER":"44136","EVENT_NO":"4408266","INSPECTION_BEGIN_DT":"01/02/2014","INSPECTION_END_DT":"03/21/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2014-01-02"},{"SOURCE_ROW_NUMBER":"391099","EVENT_NO":"4415833","INSPECTION_BEGIN_DT":"12/13/2013","INSPECTION_END_DT":"12/13/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"33154","EVENT_NO":"4415386","INSPECTION_BEGIN_DT":"11/25/2013","INSPECTION_END_DT":"12/06/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2013-11-25"},{"SOURCE_ROW_NUMBER":"78137","EVENT_NO":"4408258","INSPECTION_BEGIN_DT":"10/17/2013","INSPECTION_END_DT":"12/17/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"56.5","SUM_TOTAL_ON_SITE_HOURS":"34.5","sourceDate":"2013-10-17"},{"SOURCE_ROW_NUMBER":"690368","EVENT_NO":"4408252","INSPECTION_BEGIN_DT":"10/04/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2013-10-04"},{"SOURCE_ROW_NUMBER":"526699","EVENT_NO":"4407690","INSPECTION_BEGIN_DT":"10/02/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-10-02"},{"SOURCE_ROW_NUMBER":"523734","EVENT_NO":"4415823","INSPECTION_BEGIN_DT":"09/24/2013","INSPECTION_END_DT":"09/24/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2013-09-24"},{"SOURCE_ROW_NUMBER":"220275","EVENT_NO":"4410574","INSPECTION_BEGIN_DT":"07/08/2013","INSPECTION_END_DT":"09/26/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"217","SUM_TOTAL_ON_SITE_HOURS":"145.5","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"5740","EVENT_NO":"4410450","INSPECTION_BEGIN_DT":"06/21/2013","INSPECTION_END_DT":"06/21/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-06-21"},{"SOURCE_ROW_NUMBER":"1067621","EVENT_NO":"4415808","INSPECTION_BEGIN_DT":"06/17/2013","INSPECTION_END_DT":"06/17/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2013-06-17"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":99,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014-Q2":{"hours":0,"employees":0,"production":0},"2014-Q1":{"hours":2143,"employees":7,"production":0},"2013-Q4":{"hours":6236,"employees":19,"production":7116},"2013-Q3":{"hours":21668,"employees":46,"production":46007},"2013-Q2":{"hours":9064,"employees":27,"production":7400},"2013-Q1":{"hours":0,"employees":0,"production":0},"2012-Q4":{"hours":724,"employees":2,"production":0},"2012-Q3":{"hours":1569,"employees":3,"production":0},"2012-Q2":{"hours":1524,"employees":3,"production":0},"2012-Q1":{"hours":6080,"employees":16,"production":0},"2011-Q4":{"hours":25617,"employees":50,"production":36350},"2011-Q3":{"hours":29450,"employees":46,"production":42035}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":1910,"employees":3,"production":0},"2006":{"hours":20901,"employees":17,"production":52545},"2007":{"hours":40961,"employees":19,"production":131842},"2008":{"hours":35996,"employees":20,"production":155528},"2009":{"hours":86839,"employees":37,"production":242945},"2010":{"hours":102909,"employees":45,"production":282075},"2011":{"hours":111208,"employees":46,"production":166256},"2012":{"hours":9897,"employees":6,"production":0},"2013":{"hours":36968,"employees":31,"production":60523},"2014":{"hours":2143,"employees":7,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":46,"firstDate":"2006-08-22","lastDate":"2013-09-12","metrics":{"recentRows":0,"doseOver100":8,"actDoseTotal":2951,"pelDoseTotal":2128},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"208779","EVENT_NO":"4410574","SURVEY_DATE":"09/12/2013","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"119","ACT_DOSE_85":"9","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"208778","EVENT_NO":"4410574","SURVEY_DATE":"09/12/2013","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"17","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"208777","EVENT_NO":"4410574","SURVEY_DATE":"09/12/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"12","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"208776","EVENT_NO":"4410574","SURVEY_DATE":"09/12/2013","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","MANUFACTURER_CD":"033","ACT_DOSE_85":"15","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"208775","EVENT_NO":"4410574","SURVEY_DATE":"09/12/2013","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"27","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"208774","EVENT_NO":"4410574","SURVEY_DATE":"09/12/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"8","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"208780","EVENT_NO":"4410574","SURVEY_DATE":"09/06/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"81","PEL_DOSE_90":"79","SURVEY_TYPE":"I","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"208772","EVENT_NO":"4407532","SURVEY_DATE":"03/07/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"91","PEL_DOSE_90":"63","SURVEY_TYPE":"F","sourceDate":"2011-03-07"},{"SOURCE_ROW_NUMBER":"208771","EVENT_NO":"4407532","SURVEY_DATE":"03/07/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"120","PEL_DOSE_90":"95","SURVEY_TYPE":"F","sourceDate":"2011-03-07"},{"SOURCE_ROW_NUMBER":"208770","EVENT_NO":"4407532","SURVEY_DATE":"03/07/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"91","PEL_DOSE_90":"67","SURVEY_TYPE":"F","sourceDate":"2011-03-07"},{"SOURCE_ROW_NUMBER":"208769","EVENT_NO":"4407532","SURVEY_DATE":"03/07/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"70","PEL_DOSE_90":"39","SURVEY_TYPE":"F","sourceDate":"2011-03-07"},{"SOURCE_ROW_NUMBER":"208768","EVENT_NO":"4407532","SURVEY_DATE":"03/07/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"123","PEL_DOSE_90":"95","SURVEY_TYPE":"F","sourceDate":"2011-03-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":58,"firstDate":"2006-08-24","lastDate":"2013-06-17","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":24.7,"validSamples":55,"quartzPctTotal":487.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"86592","CASSETTE_NO":"51207138","SAMPLE_DT":"06/17/2013","QUARTZ_PCT":"08.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-06-17"},{"SOURCE_ROW_NUMBER":"22013","CASSETTE_NO":"57941787","SAMPLE_DT":"11/14/2011","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-14"},{"SOURCE_ROW_NUMBER":"128923","CASSETTE_NO":"57942165","SAMPLE_DT":"10/24/2011","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"118045","CASSETTE_NO":"57941986","SAMPLE_DT":"10/24/2011","QUARTZ_PCT":"09.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"63654","CASSETTE_NO":"57927328","SAMPLE_DT":"07/19/2011","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-07-19"},{"SOURCE_ROW_NUMBER":"140433","CASSETTE_NO":"57916431","SAMPLE_DT":"03/22/2011","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-22"},{"SOURCE_ROW_NUMBER":"89880","CASSETTE_NO":"57916392","SAMPLE_DT":"03/22/2011","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-22"},{"SOURCE_ROW_NUMBER":"299","CASSETTE_NO":"57916395","SAMPLE_DT":"03/22/2011","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-22"},{"SOURCE_ROW_NUMBER":"57157","CASSETTE_NO":"57898182","SAMPLE_DT":"12/20/2010","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-12-20"},{"SOURCE_ROW_NUMBER":"31722","CASSETTE_NO":"51109380","SAMPLE_DT":"11/29/2010","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-11-29"},{"SOURCE_ROW_NUMBER":"75915","CASSETTE_NO":"57888339","SAMPLE_DT":"09/08/2010","QUARTZ_PCT":"09.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"107059","CASSETTE_NO":"57857998","SAMPLE_DT":"05/13/2010","QUARTZ_PCT":"08.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-05-13"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":513,"firstDate":"2006-06-22","lastDate":"2013-12-10","metrics":{"ss":131,"amountDue":190400,"contested":109,"amountPaid":190400,"recentRows":0,"section104d":5,"unterminated":2,"proposedPenalty":240522},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2416687","VIOLATION_NO":"8208654","VIOLATION_ISSUE_DT":"12/10/2013","SIG_SUB":"N","PART_SECTION":"75.1714-7(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/10/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-12-10"},{"SOURCE_ROW_NUMBER":"2416686","VIOLATION_NO":"8208653","VIOLATION_ISSUE_DT":"12/10/2013","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/10/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-12-10"},{"SOURCE_ROW_NUMBER":"2416523","VIOLATION_NO":"8208702","VIOLATION_ISSUE_DT":"09/06/2013","SIG_SUB":"Y","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/06/2013","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"2416522","VIOLATION_NO":"8208701","VIOLATION_ISSUE_DT":"09/06/2013","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/06/2013","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"2416521","VIOLATION_NO":"8202000","VIOLATION_ISSUE_DT":"09/06/2013","SIG_SUB":"Y","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/06/2013","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2013-09-06"},{"SOURCE_ROW_NUMBER":"2416520","VIOLATION_NO":"8201992","VIOLATION_ISSUE_DT":"08/13/2013","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/13/2013","PROPOSED_PENALTY":"1111","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"2416519","VIOLATION_NO":"8201991","VIOLATION_ISSUE_DT":"08/13/2013","SIG_SUB":"N","PART_SECTION":"75.204(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/13/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"2416518","VIOLATION_NO":"8201990","VIOLATION_ISSUE_DT":"08/05/2013","SIG_SUB":"N","PART_SECTION":"48.11","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/05/2013","PROPOSED_PENALTY":"372","AMOUNT_DUE":"200","AMOUNT_PAID":"200","CONTESTED_IND":"N","sourceDate":"2013-08-05"},{"SOURCE_ROW_NUMBER":"2416517","VIOLATION_NO":"8201986","VIOLATION_ISSUE_DT":"07/26/2013","SIG_SUB":"N","PART_SECTION":"75.206(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/29/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-07-26"},{"SOURCE_ROW_NUMBER":"2416516","VIOLATION_NO":"8201985","VIOLATION_ISSUE_DT":"07/26/2013","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/26/2013","PROPOSED_PENALTY":"540","AMOUNT_DUE":"400","AMOUNT_PAID":"400","CONTESTED_IND":"N","sourceDate":"2013-07-26"},{"SOURCE_ROW_NUMBER":"2416515","VIOLATION_NO":"8201984","VIOLATION_ISSUE_DT":"07/24/2013","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"8","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/26/2013","PROPOSED_PENALTY":"127","AMOUNT_DUE":"102","AMOUNT_PAID":"102","CONTESTED_IND":"N","sourceDate":"2013-07-24"},{"SOURCE_ROW_NUMBER":"2416514","VIOLATION_NO":"8201983","VIOLATION_ISSUE_DT":"07/24/2013","SIG_SUB":"Y","PART_SECTION":"75.333(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/26/2013","PROPOSED_PENALTY":"334","AMOUNT_DUE":"275","AMOUNT_PAID":"275","CONTESTED_IND":"N","sourceDate":"2013-07-24"}]}],"safety":{"href":"/api/v1/mines/4407138/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4407138/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Multi-gas detectors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-7","part":"75","subchapter":"O","subpart":"R","id":"75.1714-7","citation":"30 CFR 75.1714-7","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","heading":"Roof bolting.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.204","part":"75","subchapter":"O","subpart":"C","id":"75.204","citation":"30 CFR 75.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-A/section-48.11","part":"48","subchapter":"H","subpart":"A","id":"48.11","citation":"30 CFR 48.11","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.206","heading":"Conventional roof support.","id":"75.206","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.206","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) Except in anthracite mines using non-mechanized mining systems, when conventional roof support materials are used as the only means of support—\n\n(1) The width of any opening shall not exceed 20 feet;\n\n(2) The spacing of roadway roof support shall not exceed 5 feet;\n\n(3)(i) Supports shall be installed to within 5 feet of the uncut face;\n\n(ii) When supports nearest the face must be removed to facilitate the operation of face equipment, equivalent temporary support shall be installed prior to removing the supports;\n\n(4) Straight roadways shall not exceed 16 feet wide where full overhead support is used and 14 feet wide where only posts are used;\n\n(5) Curved roadways shall not exceed 16 feet wide; and\n\n(6) The roof at the entrance of all openings along travelways which are no longer needed for storing supplies or for travel of equipment shall be supported by extending the line of support across the opening.\n\n(b) Conventional roof support materials shall meet the following specifications:\n\n(1) The minimum diameter of cross-sectional area of wooden posts shall be as follows:\n\nPost length (in inches) Diameter of round posts (in inches) Cross-sectional area of split posts (in square inches) 60 or less 4 13 Over 60 to 84 5 20 Over 84 to 108 6 28 Over 108 to 132 7 39 Over 132 to 156 8 50 Over 156 to 180 9 64 Over 180 to 204 10 79 Over 204 to 228 11 95 Over 228 12 113\n\n(2) Wooden materials used for support shall have the following dimensions:\n\n(i) Cap blocks and footings shall have flat sides and be at least 2 inches thick, 4 inches wide and 12 inches long.\n\n(ii) Crossbars shall have a minimum cross-sectional area of 24 square inches and be at least 3 inches thick.\n\n(iii) Planks shall be at least 6 inches wide and 1 inch thick.\n\n(3) Cribbing materials shall have at least two parallel flat sides.\n\n(c) A cluster of two or more posts that provide equivalent strength may be used to meet the requirements of paragraph (b)(1) of this section, except that no post shall have a diameter less than 4 inches or have a cross-sectional area less than 13 square inches.\n\n(d) Materials other than wood used for support shall have support strength at least equivalent to wooden material meeting the applicable provisions of this section.\n\n(e) Posts and jacks shall be tightly installed on solid footing.\n\n(f) When posts are installed under roof susceptible to sloughing a cap block, plank, crossbar or materials that are equally effective shall be placed between the post and the roof.\n\n(g) Blocks used for lagging between the roof and crossbars shall be spaced to distribute the load.\n\n(h) Jacks used for roof support shall be used with at least 36 square inches of roof bearing surface.\n\n[53 FR 2375, Jan. 27, 1988, as amended at 55 FR 14228, Apr. 16, 1990; 55 FR 20137, May 15, 1990]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4407138","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}