{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4407127","name":"Derby Wilson Mine","status":"Abandoned and Sealed","status_date":"2013-11-04","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Derby","operator_id":"P23653","operator_name":"Mill Branch Coal Corp","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":36.939166,"longitude":-82.836111},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2001},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"operator":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15409","name":"Paul R  Ison  et al"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|C15409|1950-01-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"1993-03-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|C07082|1993-03-01|2010-04-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"1996-12-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|C07082|1996-12-01|2010-04-18"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P02169","name":"Ambrose Branch Coal Co Inc"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"2005-02-28","validTo":"2005-08-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P02169|2005-02-28|2005-08-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15409","name":"Paul R  Ison  et al"},"object":{"type":"operator","id":"P02169","name":"Ambrose Branch Coal Co Inc"},"validFrom":"2005-02-28","validTo":"2005-08-08","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P02169|2005-02-28|C15409|1950-01-01|95522"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15409","name":"Jessica B  Ison  et al"},"object":{"type":"operator","id":"P02169","name":"Ambrose Branch Coal Co Inc"},"validFrom":"2005-02-28","validTo":"2005-08-08","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P02169|2005-02-28|C15409|1950-01-01|95523"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0063224","name":"North Star Energy, Inc."},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"2005-08-09","validTo":"2009-06-02","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|0063224|2005-08-09|2009-06-02"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16028","name":"Bradley V  Hurley"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"2005-08-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|C16028|2005-08-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16028","name":"Bradley V  Hurley"},"object":{"type":"operator","id":"0063224","name":"North Star Energy, Inc."},"validFrom":"2005-08-09","validTo":"2009-06-02","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|0063224|2005-08-09|C16028|2005-08-09|98138"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"2009-06-03","validTo":"2012-12-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P22270|2009-06-03|2012-12-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2009-06-03","validTo":"2010-04-18","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P22270|2009-06-03|C07082|1993-03-01|73679"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|C02508|2010-04-19|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P22270|2009-06-03|C02508|2010-04-19|59606"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2011-06-01","validTo":"2012-12-31","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P22270|2009-06-03|0041211|2011-06-01|2308"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"object":{"type":"mine","id":"4407127","name":"Derby Wilson Mine"},"validFrom":"2013-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P23653|2013-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"validFrom":"2013-01-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P23653|2013-01-01|0041211|2011-06-01|2309"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"validFrom":"2013-01-01","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P23653|2013-01-01|C02508|2010-04-19|59607"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P23653","name":"Mill Branch Coal Corp"},"validFrom":"2013-01-01","validTo":"2010-04-18","current":false,"derived":true,"evidenceMineId":"4407127","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407127|P23653|2013-01-01|C07082|1996-12-01|73714"}}],"coverage":{"historyRecords":9,"edgeCount":19,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":14,"firstDate":"2006-03-03","lastDate":"2013-03-29","metrics":{"daysLost":116,"injuries":13,"fatalities":0,"recentRows":0,"restrictedDays":89,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"166821","DOCUMENT_NO":"220131050008","ACCIDENT_DT":"03/29/2013","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE filed a claim with the Virginia Worker's Comp. Comm. dated 3/29/13. There is not an accident associated with this claim.","sourceDate":"2013-03-29"},{"SOURCE_ROW_NUMBER":"192554","DOCUMENT_NO":"220130770011","ACCIDENT_DT":"11/01/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"On, November 1, 2012 employee strained his right arm while lifting a 3-wheeler battery. He did not miss any work. On November 17, 2012, he was terminated as a result of company cut-backs. On February 14, 2013 employee had surgery on his right arm due to the injury on November 1, 2012","sourceDate":"2012-11-01"},{"SOURCE_ROW_NUMBER":"184026","DOCUMENT_NO":"220122150021","ACCIDENT_DT":"07/31/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Drill steel was hung in drill pot, employee engaged rotation and drill steel struck employee on left shoulder and ear causing a laceration to his ear.","sourceDate":"2012-07-31"},{"SOURCE_ROW_NUMBER":"196746","DOCUMENT_NO":"220121350037","ACCIDENT_DT":"05/11/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A Roof Fall occurred on 3 Left Panel at SS# 1209 to SS# 1227 in the #1 return entry. The fall measured Length 105' x Width 18' x Height 7'.","sourceDate":"2012-05-11"},{"SOURCE_ROW_NUMBER":"46373","DOCUMENT_NO":"220120520077","ACCIDENT_DT":"02/13/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Apprentice, Trainee","NO_INJURIES":"1","DAYS_LOST":"80","NARRATIVE":"Employee was putting rub rail back on Continuous miner. Employee set it in place and went to push rail in when it fell striking him on top of left foot. Accident occurred at MMU 001, between #2 and #3 entries at Brk #9.","sourceDate":"2012-02-13"},{"SOURCE_ROW_NUMBER":"67764","DOCUMENT_NO":"220112990001","ACCIDENT_DT":"10/24/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Changing diesel scoop battery, employee started to pull battery out and it got caught and jerked a battery cap off splashing acid in left nostril.","sourceDate":"2011-10-24"},{"SOURCE_ROW_NUMBER":"252859","DOCUMENT_NO":"220111940027","ACCIDENT_DT":"07/09/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee had moved the refuge chambers and was hooking up lifelines. After crawling under the belt line he stood up and felt pain in his lower back and right leg felt cold.","sourceDate":"2011-07-09"},{"SOURCE_ROW_NUMBER":"54897","DOCUMENT_NO":"220110200044","ACCIDENT_DT":"01/18/2011","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The EE was dropping the miner cable that was hung in the #7 heading and as he was dropping the cable he felt a pain in his lower back.","sourceDate":"2011-01-18"},{"SOURCE_ROW_NUMBER":"3436","DOCUMENT_NO":"220103260053","ACCIDENT_DT":"11/12/2010","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"As the individual was traveling underground on a Mac 8, his dinner started to move. He reached back to catch it as he started under an overcast, catching his left ear causing a laceration which required sutures.","sourceDate":"2010-11-12"},{"SOURCE_ROW_NUMBER":"248588","DOCUMENT_NO":"220103260054","ACCIDENT_DT":"11/11/2010","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The individual was traveling outside on a Lil Mac when he ran into an equipment door. He did not stop at the door switch. The ride was checked and was found to be in proper operating condition.","sourceDate":"2010-11-11"},{"SOURCE_ROW_NUMBER":"72050","DOCUMENT_NO":"220103080053","ACCIDENT_DT":"11/02/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The individual was operating the continuous miner and positioned outby the boom of the miner wearing safety glasses, when an object was thrown by the cutter head, striking himi in the head above the left eye. This is a medical only report.","sourceDate":"2010-11-02"},{"SOURCE_ROW_NUMBER":"188250","DOCUMENT_NO":"220101830053","ACCIDENT_DT":"06/29/2010","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"35","NARRATIVE":"The EE was inserting a roof bolt in the mine roof and as he raised his arm, he felt pain in his right shoulder.","sourceDate":"2010-06-29"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2013-11-04","lastDate":"2013-11-04","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":274,"firstDate":"2005-11-18","lastDate":"2013-07-08","metrics":{"ss":80,"delinquent":273,"recentRows":0,"paidPenalty":88645,"proposedPenalty":108678,"currentAssessment":91920},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1366148","VIOLATION_NO":"8202150","ISSUE_DT":"07/08/2013","CFR_STANDARD_CD":"48.29","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"1366146","VIOLATION_NO":"8202138","ISSUE_DT":"05/28/2013","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"1366145","VIOLATION_NO":"8202137","ISSUE_DT":"05/28/2013","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"1366144","VIOLATION_NO":"8202136","ISSUE_DT":"05/28/2013","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"1369066","VIOLATION_NO":"8196184","ISSUE_DT":"09/27/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1304.00","CURRENT_ASSESSMENT_AMT":"978.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"1369065","VIOLATION_NO":"8196183","ISSUE_DT":"09/27/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1304.00","CURRENT_ASSESSMENT_AMT":"978.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"1369064","VIOLATION_NO":"8196182","ISSUE_DT":"09/27/2012","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"985.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"1369071","VIOLATION_NO":"8196529","ISSUE_DT":"09/25/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1944.00","CURRENT_ASSESSMENT_AMT":"1944.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"1369070","VIOLATION_NO":"8196528","ISSUE_DT":"09/25/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"1369069","VIOLATION_NO":"8196527","ISSUE_DT":"09/25/2012","CFR_STANDARD_CD":"75.1910(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1304.00","CURRENT_ASSESSMENT_AMT":"732.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"1369068","VIOLATION_NO":"8196526","ISSUE_DT":"09/25/2012","CFR_STANDARD_CD":"75.606","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2473.00","CURRENT_ASSESSMENT_AMT":"1434.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"1369067","VIOLATION_NO":"8196525","ISSUE_DT":"09/24/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":99,"firstDate":"2011-04-04","lastDate":"2013-10-24","metrics":{"appeals":1,"decisions":99,"recentRows":0,"decisionPenalty":70089,"originalPenalty":88147},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"337147","VIOLATION_NO":"8196529","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1944.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-10-24"},{"SOURCE_ROW_NUMBER":"337146","VIOLATION_NO":"8196526","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1434.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-10-24"},{"SOURCE_ROW_NUMBER":"336316","VIOLATION_NO":"8196182","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"985.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-10-24"},{"SOURCE_ROW_NUMBER":"93607","VIOLATION_NO":"8196527","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"732.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-10-24"},{"SOURCE_ROW_NUMBER":"330399","VIOLATION_NO":"8196141","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"162.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"330398","VIOLATION_NO":"8196134","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"360.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"329848","VIOLATION_NO":"8193910","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1412.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"329775","VIOLATION_NO":"8196142","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"523.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"329594","VIOLATION_NO":"8196140","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"523.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"328484","VIOLATION_NO":"8196124","DOCKET_NO":"VA 2012-511","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"327918","VIOLATION_NO":"8193911","DOCKET_NO":"VA 2012-511","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"308.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"},{"SOURCE_ROW_NUMBER":"327873","VIOLATION_NO":"8196125","DOCKET_NO":"VA 2012-511","DECISION_DT":"09/05/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4689.00","DECISION_PENALTY_AMT":"1876.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-09-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":363,"firstDate":"2006-02-15","lastDate":"2012-09-12","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":35,"validSamples":328,"maxConcentration":5.157,"concentrationTotal":179.635},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1592805","CASS_NUM":"57982132","SMP_TAKEN_DT":"9/12/2012","CONC":".362","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"1588757","CASS_NUM":"57982026","SMP_TAKEN_DT":"9/12/2012","CONC":".278","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"1518708","CASS_NUM":"57982204","SMP_TAKEN_DT":"9/12/2012","CONC":".37","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"1272232","CASS_NUM":"57982140","SMP_TAKEN_DT":"9/12/2012","CONC":".382","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"951415","CASS_NUM":"57982170","SMP_TAKEN_DT":"9/12/2012","CONC":".534","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"701047","CASS_NUM":"57982174","SMP_TAKEN_DT":"9/12/2012","CONC":".543","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"409911","CASS_NUM":"57981998","SMP_TAKEN_DT":"9/12/2012","CONC":".198","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"1374871","CASS_NUM":"57982099","SMP_TAKEN_DT":"8/26/2012","CONC":".05","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-26"},{"SOURCE_ROW_NUMBER":"1175512","CASS_NUM":"57982394","SMP_TAKEN_DT":"8/26/2012","CONC":".303","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-26"},{"SOURCE_ROW_NUMBER":"709122","CASS_NUM":"57982011","SMP_TAKEN_DT":"8/26/2012","CONC":"1.024","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-26"},{"SOURCE_ROW_NUMBER":"605646","CASS_NUM":"57982135","SMP_TAKEN_DT":"8/26/2012","CONC":".224","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-26"},{"SOURCE_ROW_NUMBER":"325329","CASS_NUM":"57982315","SMP_TAKEN_DT":"8/26/2012","CONC":".514","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-26"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":4,"firstDate":"2006-02-23","lastDate":"2012-11-27","metrics":{"linkedIssuances":4},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":99,"firstDate":"2010-05-20","lastDate":"2012-09-27","metrics":{"decisions":99,"ssChanged":22,"recentRows":0,"decisionPenalty":70089,"proposedPenalty":88147},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"313164","CITATION_NO":"8196184","CITATION_ISSUE_DT":"09/27/2012","DOCKET_NO":"VA 2013-265","DECISION_DT":"09/04/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"978.00","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"256251","CITATION_NO":"8196183","CITATION_ISSUE_DT":"09/27/2012","DOCKET_NO":"VA 2013-265","DECISION_DT":"09/04/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"978.00","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"147654","CITATION_NO":"8196182","CITATION_ISSUE_DT":"09/27/2012","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"985.00","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"368627","CITATION_NO":"8196527","CITATION_ISSUE_DT":"09/25/2012","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","CFR_STANDARD_CODE":"75.1910(d)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"732.00","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"368199","CITATION_NO":"8196526","CITATION_ISSUE_DT":"09/25/2012","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","CFR_STANDARD_CODE":"75.606","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1434.00","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"255171","CITATION_NO":"8196529","CITATION_ISSUE_DT":"09/25/2012","DOCKET_NO":"VA 2013-102","DECISION_DT":"10/24/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1944.00","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"86046","CITATION_NO":"8191022","CITATION_ISSUE_DT":"05/31/2012","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","CFR_STANDARD_CODE":"75.342(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-05-31"},{"SOURCE_ROW_NUMBER":"429020","CITATION_NO":"8196143","CITATION_ISSUE_DT":"05/24/2012","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","CFR_STANDARD_CODE":"75.1100-1(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"176.00","sourceDate":"2012-05-24"},{"SOURCE_ROW_NUMBER":"259050","CITATION_NO":"8196142","CITATION_ISSUE_DT":"05/21/2012","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","CFR_STANDARD_CODE":"75.1909(a)(7)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"523.00","sourceDate":"2012-05-21"},{"SOURCE_ROW_NUMBER":"82702","CITATION_NO":"8196140","CITATION_ISSUE_DT":"05/21/2012","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","CFR_STANDARD_CODE":"75.1909(a)(7)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"523.00","sourceDate":"2012-05-21"},{"SOURCE_ROW_NUMBER":"26348","CITATION_NO":"8196141","CITATION_ISSUE_DT":"05/21/2012","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"162.00","sourceDate":"2012-05-21"},{"SOURCE_ROW_NUMBER":"308762","CITATION_NO":"8196135","CITATION_ISSUE_DT":"05/17/2012","DOCKET_NO":"VA 2012-554","DECISION_DT":"09/05/2013","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4689.00","DECISION_PENALTY_AMT":"3447.00","sourceDate":"2012-05-17"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":552,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":122,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":9,"firstDate":"2005-02-28","lastDate":"2013-01-01","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":6},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":77,"firstDate":"2005-04-02","lastDate":"2013-11-04","metrics":{"inspectors":146,"recentRows":0,"onSiteHours":1739.5,"inspectionHours":2783,"inspectionSamples":393},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"223077","EVENT_NO":"4407695","INSPECTION_BEGIN_DT":"11/04/2013","INSPECTION_END_DT":"11/05/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.75","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2013-11-04"},{"SOURCE_ROW_NUMBER":"839942","EVENT_NO":"4415218","INSPECTION_BEGIN_DT":"07/17/2013","INSPECTION_END_DT":"07/18/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2013-07-17"},{"SOURCE_ROW_NUMBER":"116977","EVENT_NO":"4415816","INSPECTION_BEGIN_DT":"07/11/2013","INSPECTION_END_DT":"07/11/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2013-07-11"},{"SOURCE_ROW_NUMBER":"728347","EVENT_NO":"4410438","INSPECTION_BEGIN_DT":"07/08/2013","INSPECTION_END_DT":"09/25/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"1120543","EVENT_NO":"4410435","INSPECTION_BEGIN_DT":"05/28/2013","INSPECTION_END_DT":"06/06/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.25","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"914453","EVENT_NO":"4410563","INSPECTION_BEGIN_DT":"01/04/2013","INSPECTION_END_DT":"03/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"19.5","sourceDate":"2013-01-04"},{"SOURCE_ROW_NUMBER":"386306","EVENT_NO":"4415779","INSPECTION_BEGIN_DT":"12/31/2012","INSPECTION_END_DT":"12/31/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2012-12-31"},{"SOURCE_ROW_NUMBER":"76980","EVENT_NO":"4415210","INSPECTION_BEGIN_DT":"12/17/2012","INSPECTION_END_DT":"12/18/2012","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.75","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2012-12-17"},{"SOURCE_ROW_NUMBER":"981101","EVENT_NO":"4411284","INSPECTION_BEGIN_DT":"11/05/2012","INSPECTION_END_DT":"12/17/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"31","SUM_TOTAL_ON_SITE_HOURS":"19","sourceDate":"2012-11-05"},{"SOURCE_ROW_NUMBER":"44948","EVENT_NO":"4414816","INSPECTION_BEGIN_DT":"09/28/2012","INSPECTION_END_DT":"10/10/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2012-09-28"},{"SOURCE_ROW_NUMBER":"241078","EVENT_NO":"4126504","INSPECTION_BEGIN_DT":"08/21/2012","INSPECTION_END_DT":"08/23/2012","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"39.5","SUM_TOTAL_ON_SITE_HOURS":"23.5","sourceDate":"2012-08-21"},{"SOURCE_ROW_NUMBER":"256459","EVENT_NO":"4411278","INSPECTION_BEGIN_DT":"08/17/2012","INSPECTION_END_DT":"09/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"117","SUM_TOTAL_ON_SITE_HOURS":"77.5","sourceDate":"2012-08-17"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":36,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013-Q4":{"hours":0,"employees":0,"production":0},"2013-Q3":{"hours":0,"employees":0,"production":0},"2013-Q2":{"hours":759,"employees":3,"production":0},"2013-Q1":{"hours":1279,"employees":5,"production":0},"2012-Q4":{"hours":6458,"employees":23,"production":818},"2012-Q3":{"hours":36255,"employees":69,"production":92561},"2012-Q2":{"hours":33872,"employees":69,"production":98833},"2012-Q1":{"hours":35179,"employees":69,"production":93003},"2011-Q4":{"hours":31183,"employees":67,"production":62399},"2011-Q3":{"hours":36131,"employees":59,"production":73111},"2011-Q2":{"hours":34605,"employees":51,"production":109895},"2011-Q1":{"hours":35455,"employees":49,"production":107580}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":9,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":10,"employees":1,"production":0},"2010":{"hours":64064,"employees":42,"production":143162},"2011":{"hours":137374,"employees":57,"production":352985},"2012":{"hours":111764,"employees":57,"production":285215},"2013":{"hours":2038,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":23,"firstDate":"2010-06-10","lastDate":"2011-10-23","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":1422,"pelDoseTotal":1205},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"208092","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","ACT_DOSE_85":"24","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208091","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","ACT_DOSE_85":"47","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208090","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","ACT_DOSE_85":"58","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208089","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"74","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208088","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"47","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208087","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"24","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208086","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"74","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208085","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"47","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208084","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"82","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208083","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"62","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208082","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"50","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2011-10-23"},{"SOURCE_ROW_NUMBER":"208081","EVENT_NO":"4410171","SURVEY_DATE":"10/23/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"56","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2011-10-23"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":39,"firstDate":"2006-02-15","lastDate":"2012-09-12","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":19.2,"validSamples":37,"quartzPctTotal":346.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"131497","CASSETTE_NO":"57982170","SAMPLE_DT":"09/12/2012","QUARTZ_PCT":"08.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"4072","CASSETTE_NO":"51207136","SAMPLE_DT":"09/12/2012","QUARTZ_PCT":"11.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-09-12"},{"SOURCE_ROW_NUMBER":"79737","CASSETTE_NO":"57982315","SAMPLE_DT":"08/26/2012","QUARTZ_PCT":"08.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-08-26"},{"SOURCE_ROW_NUMBER":"50212","CASSETTE_NO":"57982011","SAMPLE_DT":"08/26/2012","QUARTZ_PCT":"09.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-08-26"},{"SOURCE_ROW_NUMBER":"66845","CASSETTE_NO":"57959126","SAMPLE_DT":"04/23/2012","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-23"},{"SOURCE_ROW_NUMBER":"160279","CASSETTE_NO":"51176396","SAMPLE_DT":"02/20/2012","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2012-02-20"},{"SOURCE_ROW_NUMBER":"63745","CASSETTE_NO":"57952369","SAMPLE_DT":"02/07/2012","QUARTZ_PCT":"08.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-02-07"},{"SOURCE_ROW_NUMBER":"102040","CASSETTE_NO":"57952211","SAMPLE_DT":"02/01/2012","QUARTZ_PCT":"10.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-02-01"},{"SOURCE_ROW_NUMBER":"156084","CASSETTE_NO":"51152010","SAMPLE_DT":"11/11/2011","QUARTZ_PCT":"14.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-11"},{"SOURCE_ROW_NUMBER":"107879","CASSETTE_NO":"57941911","SAMPLE_DT":"11/01/2011","QUARTZ_PCT":"07.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-01"},{"SOURCE_ROW_NUMBER":"157476","CASSETTE_NO":"57941964","SAMPLE_DT":"10/25/2011","QUARTZ_PCT":"13.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-25"},{"SOURCE_ROW_NUMBER":"112554","CASSETTE_NO":"51148407","SAMPLE_DT":"10/08/2011","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"OVERSIZE PARTICLES","sourceDate":"2011-10-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":279,"firstDate":"2005-11-18","lastDate":"2013-07-08","metrics":{"ss":80,"amountDue":91920,"contested":2,"amountPaid":88645,"recentRows":0,"section104d":2,"unterminated":1,"proposedPenalty":108678},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2412674","VIOLATION_NO":"8202150","VIOLATION_ISSUE_DT":"07/08/2013","SIG_SUB":"N","PART_SECTION":"48.29","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/08/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"2412622","VIOLATION_NO":"8202138","VIOLATION_ISSUE_DT":"05/28/2013","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"2412621","VIOLATION_NO":"8202137","VIOLATION_ISSUE_DT":"05/28/2013","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/28/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"2412620","VIOLATION_NO":"8202136","VIOLATION_ISSUE_DT":"05/28/2013","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-05-28"},{"SOURCE_ROW_NUMBER":"2412706","VIOLATION_NO":"8196184","VIOLATION_ISSUE_DT":"09/27/2012","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/27/2012","PROPOSED_PENALTY":"1304","AMOUNT_DUE":"978","AMOUNT_PAID":"978","CONTESTED_IND":"N","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"2412705","VIOLATION_NO":"8196183","VIOLATION_ISSUE_DT":"09/27/2012","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/27/2012","PROPOSED_PENALTY":"1304","AMOUNT_DUE":"978","AMOUNT_PAID":"978","CONTESTED_IND":"N","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"2412704","VIOLATION_NO":"8196182","VIOLATION_ISSUE_DT":"09/27/2012","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/28/2012","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"985","AMOUNT_PAID":"985","CONTESTED_IND":"N","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"2412711","VIOLATION_NO":"8196529","VIOLATION_ISSUE_DT":"09/25/2012","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2012","PROPOSED_PENALTY":"1944","AMOUNT_DUE":"1944","AMOUNT_PAID":"1944","CONTESTED_IND":"N","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"2412710","VIOLATION_NO":"8196528","VIOLATION_ISSUE_DT":"09/25/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2012","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"2412709","VIOLATION_NO":"8196527","VIOLATION_ISSUE_DT":"09/25/2012","SIG_SUB":"N","PART_SECTION":"75.1910(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2012","PROPOSED_PENALTY":"1304","AMOUNT_DUE":"732","AMOUNT_PAID":"732","CONTESTED_IND":"N","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"2412708","VIOLATION_NO":"8196526","VIOLATION_ISSUE_DT":"09/25/2012","SIG_SUB":"N","PART_SECTION":"75.606","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2012","PROPOSED_PENALTY":"2473","AMOUNT_DUE":"1434","AMOUNT_PAID":"1434","CONTESTED_IND":"N","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"2412707","VIOLATION_NO":"8196525","VIOLATION_ISSUE_DT":"09/24/2012","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/24/2012","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"243","CONTESTED_IND":"N","sourceDate":"2012-09-24"}]}],"safety":{"href":"/api/v1/mines/4407127/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4407127/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 48.29","heading":"Records of training.","id":"48.29","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.29","part":"48","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"B","subpartHeading":"Subpart B—Training and Retraining of Miners Working at Surface Mines and Surface Areas of Underground Mines","text":"(a) Upon a miner's completion of each MSHA approved training program, the operator shall record and certify on MSHA form 5000-23 that the miner has received the specified training. A copy of the training certificate shall be given to the miner at the completion of the training. The training certificates for each miner shall be available at the mine site for inspection by MSHA and for examination by the miners, the miners' representative and State inspection agencies. When a miner leaves the operator's employ, the miner shall be entitled to a copy of his training certificates.\n\n(b) False certification that training was given shall be punishable under section 110 (a) and (f) of the Act.\n\n(c) Copies of training certificates for currently employed miners shall be kept at the mine site for 2 years, or for 60 days after termination of employment.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[43 FR 47459, Oct. 13, 1978, as amended at 47 FR 14706, Apr. 6, 1982; 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1910","heading":"Nonpermissible diesel-powered equipment; electrical system design and performance requirements.","id":"75.1910","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1910","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"Electrical circuits and components associated with or connected to electrical systems on nonpermissible diesel-powered equipment utilizing storage batteries and integral charging systems, except for the special category of equipment under § 75.1908(d), must conform to the following requirements:\n\n(a) Overload and short circuit protection must be provided for electric circuits and components in accordance with §§ 75.518 and 75.518-1 of this part;\n\n(b) Each electric conductor from the battery to the starting motor must be protected against short circuit by fuses or other circuit-interrupting devices placed as near as practicable to the battery terminals;\n\n(c) Each branch circuit conductor connected to the main circuit between the battery and charging generator must be protected against short circuit by fuses or other automatic circuit-interrupting devices;\n\n(d) The electrical system shall be equipped with a circuit-interrupting device by means of which all power conductors can be deenergized. The device must be located as close as practicable to the battery terminals and be designed to operate within its electrical rating without damage. The device shall not automatically reset after being actuated. All magnetic circuit-interrupting devices must be mounted in a manner to preclude their closing by force of gravity;\n\n(e) Each motor and charging generator must be protected by an automatic overcurrent device. One protective device will be acceptable when two motors of the same rating operate simultaneously and perform virtually the same duty;\n\n(f) Each ungrounded conductor must have insulation compatible with the impressed voltage. Insulation materials must be resistant to deterioration from engine heat and oil. Electric conductors must meet the applicable requirements of §§ 75.513 and 75.513-1, except electric conductors for starting motors, which must only meet the requirements of § 75.513;\n\n(g) All wiring must have adequate mechanical protection to prevent damage to the cable that might result in short circuits;\n\n(h) Sharp edges and corners must be removed at all points where there is a possibility of damaging wires, cables, or conduits by cutting or abrasion. The insulation of the cables within a battery box must be protected against abrasion;\n\n(i) When insulated wires other than cables pass through metal frames, the holes must be substantially bushed with insulated bushings. Cables must enter metal frames of motors, splice boxes, and electric components only through proper fittings. All electrical connections and splices must be mechanically and electrically efficient, and suitable connectors shall be used. All electrical connectors or splices in insulated wire must be reinsulated at least to the same degree of protection as the remainder of the wire;\n\n(j) The battery must be secured to prevent movement, and must be protected from external damage by position. Batteries that are not protected from external damage by position must be enclosed in a battery box. Flame-resistant insulation treated to resist chemical reaction to electrolyte must be provided on battery connections to prevent battery terminals from contacting conducting surfaces;\n\n(k) A battery box, including the cover, must be constructed of steel with a minimum thickness of 1/8 inch, or of a material other than steel that provides equivalent strength;\n\n(l) Battery-box covers must be lined with a flame-resistant insulating material permanently attached to the underside of the cover, unless equivalent protection is provided. Battery-box covers must be provided with a means for securing them in closed position. At least 1/2 inch of air space must be provided between the underside of the cover and the top of the battery, including terminals;\n\n(m) Battery boxes must be provided with ventilation openings to prevent the accumulation of flammable or toxic gases or vapors within the battery box. The size and locations of openings for ventilation must prevent direct access to battery terminals;\n\n(n) The battery must be insulated from the battery-box walls and supported on insulating materials. Insulating materials that may be subject to chemical reaction with electrolyte must be treated to resist such action; and\n\n(o) Drainage holes must be provided in the bottom of each battery box.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.606","heading":"Protection of trailing cables.","id":"75.606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.606","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nTrailing cables shall be adequately protected to prevent damage by mobile equipment.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4407127","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}