{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4407093","name":"No. 1","status":"Abandoned and Sealed","status_date":"2006-03-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Russell","nearest_town":"St. Paul","operator_id":"0053714","operator_name":"Double A Mining, Inc.","controller_id":"C14881","controller_name":"O A  Stump Jr","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":36.972777,"longitude":-82.237222},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":290},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4407093","name":"No. 1"},"operator":{"type":"operator","id":"0053714","name":"Double A Mining, Inc."},"controller":{"type":"controller","id":"C14881","name":"O A  Stump Jr"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051969","name":"Double A Mining, Inc."},"object":{"type":"mine","id":"4407093","name":"No. 1"},"validFrom":"2004-02-05","validTo":"2004-04-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407093|0051969|2004-02-05|2004-04-12"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14929","name":"Steven Rocky  Justus"},"object":{"type":"mine","id":"4407093","name":"No. 1"},"validFrom":"2004-02-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407093|C14929|2004-02-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14929","name":"Steven Rocky  Justus"},"object":{"type":"operator","id":"0051969","name":"Double A Mining, Inc."},"validFrom":"2004-02-05","validTo":"2004-04-12","current":false,"derived":true,"evidenceMineId":"4407093","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407093|0051969|2004-02-05|C14929|2004-02-05|94282"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0053714","name":"Double A Mining, Inc."},"object":{"type":"mine","id":"4407093","name":"No. 1"},"validFrom":"2004-04-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407093|0053714|2004-04-13|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14881","name":"O A  Stump Jr et al"},"object":{"type":"mine","id":"4407093","name":"No. 1"},"validFrom":"2004-04-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407093|C14881|2004-04-13|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14881","name":"O A  Stump Jr et al"},"object":{"type":"operator","id":"0053714","name":"Double A Mining, Inc."},"validFrom":"2004-04-13","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407093","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407093|0053714|2004-04-13|C14881|2004-04-13|94187"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":2,"firstDate":"2004-04-23","lastDate":"2004-12-24","metrics":{"daysLost":0,"injuries":0,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"76517","DOCUMENT_NO":"220050060034","ACCIDENT_DT":"12/24/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"HIGH WALL ROCK FELL DUE TO POSSIBLE WEATHER, RAIN AND FREEZE TEMPERATURE CHANGES.","sourceDate":"2004-12-24"},{"SOURCE_ROW_NUMBER":"50612","DOCUMENT_NO":"220041380047","ACCIDENT_DT":"04/23/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"HIGHWALL AT MOUTH OF DRIFT AT #1 ENTRY. FAN ENTRY FELL DURING IDLE SHIFT. 6' THICK EXTENDING 15' TO INBY DRIFT MOUTH. WE REBUILT CANOPY - CRIBBED ROOF FROM TOP OF CANOPY - INSTALLED HEIZEMAN HEADERS AND JACKS - RELEASED ON 4-30-04.","sourceDate":"2004-04-23"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-03-30","lastDate":"2006-03-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":90,"firstDate":"2004-04-23","lastDate":"2005-03-30","metrics":{"ss":37,"delinquent":90,"recentRows":0,"paidPenalty":0,"proposedPenalty":17244,"currentAssessment":17244},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"905918","VIOLATION_NO":"7341424","ISSUE_DT":"03/30/2005","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"463.00","CURRENT_ASSESSMENT_AMT":"463.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-03-30"},{"SOURCE_ROW_NUMBER":"905917","VIOLATION_NO":"7341423","ISSUE_DT":"03/30/2005","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"463.00","CURRENT_ASSESSMENT_AMT":"463.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-03-30"},{"SOURCE_ROW_NUMBER":"898071","VIOLATION_NO":"7336369","ISSUE_DT":"12/29/2004","CFR_STANDARD_CD":"75.1710-1(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"898070","VIOLATION_NO":"7336368","ISSUE_DT":"12/29/2004","CFR_STANDARD_CD":"72.520","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"898069","VIOLATION_NO":"7336367","ISSUE_DT":"12/29/2004","CFR_STANDARD_CD":"75.311(f)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3400.00","CURRENT_ASSESSMENT_AMT":"3400.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"898068","VIOLATION_NO":"7336351","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"77.1004","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"84.00","CURRENT_ASSESSMENT_AMT":"84.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"898067","VIOLATION_NO":"7336350","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"898066","VIOLATION_NO":"7336349","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"898065","VIOLATION_NO":"7336348","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"77.1605(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"898064","VIOLATION_NO":"7336347","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"77.206(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"898063","VIOLATION_NO":"7336346","ISSUE_DT":"12/27/2004","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"327.00","CURRENT_ASSESSMENT_AMT":"327.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"898062","VIOLATION_NO":"7336345","ISSUE_DT":"12/22/2004","CFR_STANDARD_CD":"75.333(e)(1)(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":50,"firstDate":"2004-06-23","lastDate":"2005-01-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":10,"validSamples":40,"maxConcentration":13.398,"concentrationTotal":36.534},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"992854","CASS_NUM":"50714043","SMP_TAKEN_DT":"1/14/2005","CONC":".34","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-14"},{"SOURCE_ROW_NUMBER":"66525","CASS_NUM":"50714059","SMP_TAKEN_DT":"12/31/2004","CONC":".25","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-31"},{"SOURCE_ROW_NUMBER":"1621832","CASS_NUM":"50767235","SMP_TAKEN_DT":"12/30/2004","CONC":".146","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-30"},{"SOURCE_ROW_NUMBER":"149827","CASS_NUM":"50714068","SMP_TAKEN_DT":"12/30/2004","CONC":".132","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-30"},{"SOURCE_ROW_NUMBER":"563486","CASS_NUM":"50714069","SMP_TAKEN_DT":"12/29/2004","CONC":".208","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"491318","CASS_NUM":"50767236","SMP_TAKEN_DT":"12/17/2004","CONC":".103","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-17"},{"SOURCE_ROW_NUMBER":"1323570","CASS_NUM":"57543218","SMP_TAKEN_DT":"11/23/2004","CONC":".088","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"564134","CASS_NUM":"57542940","SMP_TAKEN_DT":"11/23/2004","CONC":".342","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"550480","CASS_NUM":"57543130","SMP_TAKEN_DT":"11/23/2004","CONC":".078","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"152729","CASS_NUM":"57543225","SMP_TAKEN_DT":"11/23/2004","CONC":".065","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"141069","CASS_NUM":"57543211","SMP_TAKEN_DT":"11/23/2004","CONC":".091","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"99475","CASS_NUM":"57543223","SMP_TAKEN_DT":"11/23/2004","CONC":".105","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-23"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2004-09-09","lastDate":"2004-09-09","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2004-02-05","lastDate":"2004-04-13","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":27,"firstDate":"2004-03-18","lastDate":"2006-03-30","metrics":{"inspectors":38,"recentRows":0,"onSiteHours":279.25,"inspectionHours":594.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"970990","EVENT_NO":"4160162","INSPECTION_BEGIN_DT":"03/30/2006","INSPECTION_END_DT":"03/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2006-03-30"},{"SOURCE_ROW_NUMBER":"428011","EVENT_NO":"4160037","INSPECTION_BEGIN_DT":"11/09/2005","INSPECTION_END_DT":"11/09/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-11-09"},{"SOURCE_ROW_NUMBER":"208008","EVENT_NO":"4160035","INSPECTION_BEGIN_DT":"09/15/2005","INSPECTION_END_DT":"09/16/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2005-09-15"},{"SOURCE_ROW_NUMBER":"776752","EVENT_NO":"4160066","INSPECTION_BEGIN_DT":"04/04/2005","INSPECTION_END_DT":"05/11/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"35.25","SUM_TOTAL_ON_SITE_HOURS":"6.75","sourceDate":"2005-04-04"},{"SOURCE_ROW_NUMBER":"264964","EVENT_NO":"4125289","INSPECTION_BEGIN_DT":"02/24/2005","INSPECTION_END_DT":"02/25/2005","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2005-02-24"},{"SOURCE_ROW_NUMBER":"309555","EVENT_NO":"4147390","INSPECTION_BEGIN_DT":"01/26/2005","INSPECTION_END_DT":"03/30/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"29.75","SUM_TOTAL_ON_SITE_HOURS":"9.25","sourceDate":"2005-01-26"},{"SOURCE_ROW_NUMBER":"307937","EVENT_NO":"4142539","INSPECTION_BEGIN_DT":"11/17/2004","INSPECTION_END_DT":"12/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"108","SUM_TOTAL_ON_SITE_HOURS":"56.75","sourceDate":"2004-11-17"},{"SOURCE_ROW_NUMBER":"1001985","EVENT_NO":"4128080","INSPECTION_BEGIN_DT":"11/03/2004","INSPECTION_END_DT":"11/04/2004","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2004-11-03"},{"SOURCE_ROW_NUMBER":"21206","EVENT_NO":"4142265","INSPECTION_BEGIN_DT":"09/20/2004","INSPECTION_END_DT":"09/28/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-09-20"},{"SOURCE_ROW_NUMBER":"105173","EVENT_NO":"4142262","INSPECTION_BEGIN_DT":"09/07/2004","INSPECTION_END_DT":"09/08/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.25","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2004-09-07"},{"SOURCE_ROW_NUMBER":"416294","EVENT_NO":"4128502","INSPECTION_BEGIN_DT":"09/03/2004","INSPECTION_END_DT":"09/22/2004","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2004-09-03"},{"SOURCE_ROW_NUMBER":"1124886","EVENT_NO":"4142258","INSPECTION_BEGIN_DT":"08/26/2004","INSPECTION_END_DT":"09/02/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.25","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2004-08-26"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q3":{"hours":0,"employees":0,"production":0},"2006-Q1":{"hours":0,"employees":0,"production":0},"2005-Q4":{"hours":0,"employees":0,"production":0},"2005-Q1":{"hours":835,"employees":5,"production":5295},"2004-Q4":{"hours":3164,"employees":8,"production":16344},"2004-Q3":{"hours":2680,"employees":7,"production":14547},"2004-Q2":{"hours":3000,"employees":5,"production":4225},"2004-Q1":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":8844,"employees":7,"production":35116},"2005":{"hours":835,"employees":5,"production":5295}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":6,"firstDate":"2004-08-26","lastDate":"2004-09-20","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":697,"pelDoseTotal":630},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"207518","EVENT_NO":"4142265","SURVEY_DATE":"09/20/2004","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"29","PEL_DOSE_90":"15","SURVEY_TYPE":"F","sourceDate":"2004-09-20"},{"SOURCE_ROW_NUMBER":"207517","EVENT_NO":"4142262","SURVEY_DATE":"09/07/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"62","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2004-09-07"},{"SOURCE_ROW_NUMBER":"207516","EVENT_NO":"4142262","SURVEY_DATE":"09/07/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"83","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2004-09-07"},{"SOURCE_ROW_NUMBER":"207515","EVENT_NO":"4142262","SURVEY_DATE":"09/07/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"40","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2004-09-07"},{"SOURCE_ROW_NUMBER":"207514","EVENT_NO":"4142262","SURVEY_DATE":"09/07/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"41","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2004-09-07"},{"SOURCE_ROW_NUMBER":"207513","EVENT_NO":"4142259","SURVEY_DATE":"08/26/2004","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"442","PEL_DOSE_90":"434","SURVEY_TYPE":"I","sourceDate":"2004-08-26"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":1,"firstDate":"2004-09-21","lastDate":"2004-09-21","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.9,"validSamples":1,"quartzPctTotal":6.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"38914","CASSETTE_NO":"57542879","SAMPLE_DT":"09/21/2004","QUARTZ_PCT":"06.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-09-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":97,"firstDate":"2004-04-23","lastDate":"2005-05-11","metrics":{"ss":38,"amountDue":17244,"contested":0,"amountPaid":0,"recentRows":0,"section104d":3,"unterminated":2,"proposedPenalty":17244},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2409591","VIOLATION_NO":"7341300","VIOLATION_ISSUE_DT":"05/11/2005","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/05/2006","CONTESTED_IND":"N","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"2409590","VIOLATION_NO":"7341299","VIOLATION_ISSUE_DT":"05/11/2005","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/05/2006","CONTESTED_IND":"N","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"2409589","VIOLATION_NO":"7341424","VIOLATION_ISSUE_DT":"03/30/2005","SIG_SUB":"Y","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"463","AMOUNT_DUE":"463","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-03-30"},{"SOURCE_ROW_NUMBER":"2409588","VIOLATION_NO":"7341423","VIOLATION_ISSUE_DT":"03/30/2005","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"463","AMOUNT_DUE":"463","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-03-30"},{"SOURCE_ROW_NUMBER":"2409679","VIOLATION_NO":"7336369","VIOLATION_ISSUE_DT":"12/29/2004","SIG_SUB":"N","PART_SECTION":"75.1710-1(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/29/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"2409678","VIOLATION_NO":"7336368","VIOLATION_ISSUE_DT":"12/29/2004","SIG_SUB":"N","PART_SECTION":"72.520","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/29/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"2409677","VIOLATION_NO":"7336367","VIOLATION_ISSUE_DT":"12/29/2004","SIG_SUB":"Y","PART_SECTION":"75.311(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Fatal","NO_AFFECTED":"7","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"12/29/2004","PROPOSED_PENALTY":"3400","AMOUNT_DUE":"3400","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"2409676","VIOLATION_NO":"7336366","VIOLATION_ISSUE_DT":"12/29/2004","SIG_SUB":"Y","SECTION_OF_ACT":"107(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/29/2004","CONTESTED_IND":"N","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"2409675","VIOLATION_NO":"7336365","VIOLATION_ISSUE_DT":"12/29/2004","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/29/2004","CONTESTED_IND":"N","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"2409674","VIOLATION_NO":"7336351","VIOLATION_ISSUE_DT":"12/27/2004","SIG_SUB":"Y","PART_SECTION":"77.1004","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2004","PROPOSED_PENALTY":"84","AMOUNT_DUE":"84","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"2409673","VIOLATION_NO":"7336350","VIOLATION_ISSUE_DT":"12/27/2004","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/29/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-12-27"},{"SOURCE_ROW_NUMBER":"2409672","VIOLATION_NO":"7336349","VIOLATION_ISSUE_DT":"12/27/2004","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/27/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-12-27"}]}],"safety":{"href":"/api/v1/mines/4407093/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4407093/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":3},{"chapter":"I","heading":"Canopies or cabs; self-propelled diesel-powered and electric face equipment; installation requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1710-1","part":"75","subchapter":"O","subpart":"R","id":"75.1710-1","citation":"30 CFR 75.1710-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Diesel equipment inventory.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-D/section-72.520","part":"72","subchapter":"O","subpart":"D","id":"72.520","citation":"30 CFR 72.520","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Main mine fan operation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.311","part":"75","subchapter":"O","subpart":"D","id":"75.311","citation":"30 CFR 75.311","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Ground control; inspection and maintenance; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-K/section-77.1004","part":"77","subchapter":"O","subpart":"K","id":"77.1004","citation":"30 CFR 77.1004","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4407093","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}