{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4407046","name":"Locust Thicket","status":"Abandoned and Sealed","status_date":"2014-09-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Buchanan","nearest_town":"Breaks","operator_id":"P21542","operator_name":"Banner Blue Coal Company","controller_id":"0085453","controller_name":"Metinvest B V","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.323333,"longitude":-82.261944},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":4749},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4407046","name":"Locust Thicket"},"operator":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"controller":{"type":"controller","id":"0085453","name":"Metinvest B V"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13160","name":"Southern Mining Co"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"1985-09-27","validTo":"2005-12-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|C13160|1985-09-27|2005-12-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12338","name":"Gary A  Horn"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"1991-07-22","validTo":"2005-10-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|C12338|1991-07-22|2005-10-19"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07550","name":"Sam  Blankenship"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2001-01-29","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|C07550|2001-01-29|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17163","name":"Rapoca Energy Company, LLC"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2002-03-07","validTo":"2003-08-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P17163|2002-03-07|2003-08-18"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13160","name":"Southern Mining Co"},"object":{"type":"operator","id":"P17163","name":"Rapoca Energy Company, LLC"},"validFrom":"2002-03-07","validTo":"2003-08-18","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P17163|2002-03-07|C13160|1985-09-27|88877"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24533","name":"Bee Tree Coal Corporation"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2003-08-19","validTo":"2005-10-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P24533|2003-08-19|2005-10-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07550","name":"Sam  Blankenship"},"object":{"type":"operator","id":"P24533","name":"Bee Tree Coal Corporation"},"validFrom":"2003-08-19","validTo":"2005-10-19","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P24533|2003-08-19|C07550|2001-01-29|74963"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2005-10-20","validTo":"2011-12-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2005-10-20|2011-12-14"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07550","name":"Sam  Blankenship"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2005-10-20","validTo":"2006-01-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|C07550|2005-10-20|2006-01-22"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07550","name":"Sam  Blankenship"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2005-10-20","validTo":"2006-01-22","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2005-10-20|C07550|2005-10-20|74984"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12338","name":"Gary A  Horn"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2005-10-20","validTo":"2005-10-19","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2005-10-20|C12338|1991-07-22|86677"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2006-01-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|C00375|2006-01-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"operator","id":"P17163","name":"Rapoca Energy Company, LLC"},"validFrom":"2006-01-02","validTo":"2003-08-18","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P17163|2002-03-07|C00375|2006-01-02|46709"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2006-01-23","validTo":"2009-04-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|C00375|2006-01-23|2009-04-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2006-01-23","validTo":"2009-04-29","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2005-10-20|C00375|2006-01-23|46747"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2009-04-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|0085453|2009-04-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2009-04-30","validTo":"2011-12-14","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2005-10-20|0085453|2009-04-30|13553"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0090773","name":"J B  Wallace"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2010-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|0090773|2010-02-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0107305","name":"Hanna Coal Co., Inc."},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2011-12-15","validTo":"2012-12-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|0107305|2011-12-15|2012-12-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0090773","name":"J B  Wallace"},"object":{"type":"operator","id":"0107305","name":"Hanna Coal Co., Inc."},"validFrom":"2011-12-15","validTo":"2012-12-13","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|0107305|2011-12-15|0090773|2010-02-01|14563"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"object":{"type":"mine","id":"4407046","name":"Locust Thicket"},"validFrom":"2012-12-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2012-12-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085453","name":"Metinvest B V"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2012-12-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2012-12-14|0085453|2009-04-30|13554"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00375","name":"United  Company"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2012-12-14","validTo":"2009-04-29","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2012-12-14|C00375|2006-01-23|46748"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07550","name":"Sam  Blankenship"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2012-12-14","validTo":"2006-01-22","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2012-12-14|C07550|2005-10-20|74985"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12338","name":"Gary A  Horn"},"object":{"type":"operator","id":"P21542","name":"Banner Blue Coal Company"},"validFrom":"2012-12-14","validTo":"2005-10-19","current":false,"derived":true,"evidenceMineId":"4407046","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407046|P21542|2012-12-14|C12338|1991-07-22|86678"}}],"coverage":{"historyRecords":12,"edgeCount":25,"intervalAnomalies":5,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":39,"firstDate":"2004-10-18","lastDate":"2012-08-06","metrics":{"daysLost":1235,"injuries":34,"fatalities":0,"recentRows":0,"restrictedDays":123,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"54892","DOCUMENT_NO":"220122340010","ACCIDENT_DT":"08/06/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Laid right hand on head of roof bolter. Hit up lever pinch little finger between head are and boom jack.","sourceDate":"2012-08-06"},{"SOURCE_ROW_NUMBER":"261569","DOCUMENT_NO":"220112160028","ACCIDENT_DT":"07/22/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"22","NARRATIVE":"Employee was working on the miner and as he was lifting on the rub rail to install it he felt a pain in his groin area. He continued to work and started missing work on July 26 2011 due to a hernia which required surgery.","sourceDate":"2011-07-22"},{"SOURCE_ROW_NUMBER":"171152","DOCUMENT_NO":"220112060005","ACCIDENT_DT":"07/11/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"56","NARRATIVE":"Employee was riding the mantrip to the surface, riding on the off side, as the mantrip was getting ready to go into a turn it scrubbed the rib. The employee got his left foot (toes area) caught between the rib and mantrip railing causing a laceration to the big toe and his big toe and the one next to it was also broken.","sourceDate":"2011-07-11"},{"SOURCE_ROW_NUMBER":"63430","DOCUMENT_NO":"220111110033","ACCIDENT_DT":"04/09/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping with a belt move and a piece of draw rock fell and hit his hip as he was hanging cable near the tail piece in the face area.","sourceDate":"2011-04-09"},{"SOURCE_ROW_NUMBER":"119296","DOCUMENT_NO":"220110390006","ACCIDENT_DT":"01/31/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"As employee was bolting top a piece of rock fell from the rib and hit him in the left hip and knocked him into the bolt tray chipping his front right tooth. Employee stated that he checked the rib before bolting and it looked good. He returned to work on his next scheduled shift.","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"3425","DOCUMENT_NO":"220103340009","ACCIDENT_DT":"11/17/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Transit man, Surveyor/Transit worker","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was picking up a channel sample that his helper was chipping off of the rib and a piece of rock fell and hit his right hand causing a laceration to the ring and little finger that took sutures to close the lacerations. He was wearing gloves.","sourceDate":"2010-11-17"},{"SOURCE_ROW_NUMBER":"97799","DOCUMENT_NO":"220103120001","ACCIDENT_DT":"10/27/2010","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"Employee was helping install an air lock door approximately one break inside the mine. They had scaled the top. Later on a piece of rock 10\"WX10\"LX3\" thick fell and hit him on the back as he was bent over.","sourceDate":"2010-10-27"},{"SOURCE_ROW_NUMBER":"231322","DOCUMENT_NO":"220102990018","ACCIDENT_DT":"10/15/2010","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Approximately one break underground EE was going through an air lock door when the door came back shut and hit him on the right shoulder. He continued to work and was placed on restricted duty when he was diagnosed with a chipped bone in his shoulder.","sourceDate":"2010-10-15"},{"SOURCE_ROW_NUMBER":"89327","DOCUMENT_NO":"220102990030","ACCIDENT_DT":"10/11/2010","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping hang an air lock door approx. one break inside and as he lifted he felt pain in his lower back. He was diagnosed as having a strain and was put on light duty. He has a return to work at full duty slip.","sourceDate":"2010-10-11"},{"SOURCE_ROW_NUMBER":"24960","DOCUMENT_NO":"220102880024","ACCIDENT_DT":"10/04/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"15","NARRATIVE":"Employee was cutting a hole in a piece of belt when the knife slipped and hit him on the right leg two inches above the knee. He was going to use the piece of belt to drag rock dust to a trickle duster a few breaks away. Three sutures were used to close the laceration.","sourceDate":"2010-10-04"},{"SOURCE_ROW_NUMBER":"97798","DOCUMENT_NO":"220102590012","ACCIDENT_DT":"09/01/2010","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"113","NARRATIVE":"Employee was backing a 3 wheeler up on the belt line to check a rib near the #5 drive when he backed up on some rock and caused his head to go into the top. A musle was pulled in his neck. He is working on restricted duty. Additional days will be reported when he returns to full duty.","sourceDate":"2010-09-01"},{"SOURCE_ROW_NUMBER":"257154","DOCUMENT_NO":"220102420032","ACCIDENT_DT":"08/21/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was picking up belt structure outby the loadout in a break and as he picked up one piece another piece lying on the first one hit him above the left eye toward the center of the forehead causing a laceration that took 2 sutures to close.","sourceDate":"2010-08-21"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-09-12","lastDate":"2014-09-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1056,"firstDate":"2003-10-08","lastDate":"2012-11-09","metrics":{"ss":321,"delinquent":1054,"recentRows":0,"paidPenalty":431950.67,"proposedPenalty":497219,"currentAssessment":438735},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1383317","VIOLATION_NO":"8194671","ISSUE_DT":"11/09/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-09"},{"SOURCE_ROW_NUMBER":"1383316","VIOLATION_NO":"8194670","ISSUE_DT":"11/09/2012","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-09"},{"SOURCE_ROW_NUMBER":"1383315","VIOLATION_NO":"8194669","ISSUE_DT":"11/09/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-09"},{"SOURCE_ROW_NUMBER":"1383358","VIOLATION_NO":"8202591","ISSUE_DT":"10/26/2012","CFR_STANDARD_CD":"75.1100-2(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-26"},{"SOURCE_ROW_NUMBER":"1383357","VIOLATION_NO":"8202590","ISSUE_DT":"10/25/2012","CFR_STANDARD_CD":"75.1505(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-25"},{"SOURCE_ROW_NUMBER":"1383356","VIOLATION_NO":"8202589","ISSUE_DT":"10/24/2012","CFR_STANDARD_CD":"75.1403-10(l)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-24"},{"SOURCE_ROW_NUMBER":"1383355","VIOLATION_NO":"8202588","ISSUE_DT":"10/18/2012","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-18"},{"SOURCE_ROW_NUMBER":"1383354","VIOLATION_NO":"8202587","ISSUE_DT":"10/18/2012","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-18"},{"SOURCE_ROW_NUMBER":"1383353","VIOLATION_NO":"8202586","ISSUE_DT":"10/17/2012","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"1383352","VIOLATION_NO":"8202585","ISSUE_DT":"10/17/2012","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"1383351","VIOLATION_NO":"8202584","ISSUE_DT":"10/17/2012","CFR_STANDARD_CD":"75.1714-7(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"1383350","VIOLATION_NO":"8202583","ISSUE_DT":"10/17/2012","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-17"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":154,"firstDate":"2004-04-24","lastDate":"2013-12-13","metrics":{"appeals":0,"decisions":154,"recentRows":0,"decisionPenalty":127382,"originalPenalty":187332},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"313111","VIOLATION_NO":"8190239","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"662.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"313099","VIOLATION_NO":"8190235","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"312683","VIOLATION_NO":"8182418","DOCKET_NO":"VA 2012-68","DECISION_DT":"12/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6600.00","DECISION_PENALTY_AMT":"3840.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"79345","VIOLATION_NO":"8190240","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"78861","VIOLATION_NO":"8190238","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"78860","VIOLATION_NO":"8187092","DOCKET_NO":"VA 2012-67","DECISION_DT":"12/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"127.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"309209","VIOLATION_NO":"8179339","DOCKET_NO":"VA 2011-697","DECISION_DT":"11/25/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1750.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-11-25"},{"SOURCE_ROW_NUMBER":"76779","VIOLATION_NO":"8186072","DOCKET_NO":"VA 2011-697","DECISION_DT":"11/25/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2901.00","DECISION_PENALTY_AMT":"2180.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-11-25"},{"SOURCE_ROW_NUMBER":"76519","VIOLATION_NO":"8185323","DOCKET_NO":"VA 2011-697","DECISION_DT":"11/25/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"873.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-11-25"},{"SOURCE_ROW_NUMBER":"304263","VIOLATION_NO":"8179330","DOCKET_NO":"VA 2011-571","DECISION_DT":"10/25/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1750.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-10-25"},{"SOURCE_ROW_NUMBER":"303529","VIOLATION_NO":"9870541","DOCKET_NO":"VA 2011-521","DECISION_DT":"09/12/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1569.00","DECISION_PENALTY_AMT":"1569.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2013-09-12"},{"SOURCE_ROW_NUMBER":"236568","VIOLATION_NO":"8160884","DOCKET_NO":"VA 2009-149","DECISION_DT":"02/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"317.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2013-02-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":877,"firstDate":"2003-11-06","lastDate":"2012-11-26","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":230,"validSamples":647,"maxConcentration":7.167,"concentrationTotal":523.208},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1661145","CASS_NUM":"57985922","SMP_TAKEN_DT":"11/26/2012","CONC":".347","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-26"},{"SOURCE_ROW_NUMBER":"1238624","CASS_NUM":"57986449","SMP_TAKEN_DT":"11/26/2012","CONC":".265","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-26"},{"SOURCE_ROW_NUMBER":"1105762","CASS_NUM":"57985917","SMP_TAKEN_DT":"11/26/2012","CONC":".071","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-26"},{"SOURCE_ROW_NUMBER":"978739","CASS_NUM":"57985928","SMP_TAKEN_DT":"11/26/2012","CONC":".107","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-26"},{"SOURCE_ROW_NUMBER":"794715","CASS_NUM":"57985927","SMP_TAKEN_DT":"11/26/2012","CONC":".441","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-26"},{"SOURCE_ROW_NUMBER":"582246","CASS_NUM":"57985911","SMP_TAKEN_DT":"11/26/2012","CONC":".727","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-26"},{"SOURCE_ROW_NUMBER":"565535","CASS_NUM":"57986435","SMP_TAKEN_DT":"11/26/2012","CONC":".452","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-26"},{"SOURCE_ROW_NUMBER":"1430772","CASS_NUM":"57986393","SMP_TAKEN_DT":"11/19/2012","CONC":".151","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"1222051","CASS_NUM":"57985934","SMP_TAKEN_DT":"11/19/2012","CONC":".143","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"1168708","CASS_NUM":"57986386","SMP_TAKEN_DT":"11/19/2012","CONC":".872","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"1001474","CASS_NUM":"57985923","SMP_TAKEN_DT":"11/19/2012","CONC":".267","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"},{"SOURCE_ROW_NUMBER":"740225","CASS_NUM":"57986432","SMP_TAKEN_DT":"11/19/2012","CONC":".162","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-19"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":23,"firstDate":"2004-01-21","lastDate":"2010-11-10","metrics":{"linkedIssuances":23},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":142,"firstDate":"2004-10-13","lastDate":"2011-08-31","metrics":{"decisions":142,"ssChanged":32,"recentRows":0,"decisionPenalty":126392,"proposedPenalty":186350},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"423952","CITATION_NO":"8187092","CITATION_ISSUE_DT":"08/31/2011","DOCKET_NO":"VA 2012-67","DECISION_DT":"12/13/2013","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"127.00","sourceDate":"2011-08-31"},{"SOURCE_ROW_NUMBER":"426548","CITATION_NO":"8190238","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"199730","CITATION_NO":"8190239","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"662.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"23880","CITATION_NO":"8190240","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","CFR_STANDARD_CODE":"77.1000","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":".00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"423121","CITATION_NO":"8190235","CITATION_ISSUE_DT":"08/24/2011","DOCKET_NO":"VA 2012-69","DECISION_DT":"12/13/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","sourceDate":"2011-08-24"},{"SOURCE_ROW_NUMBER":"306212","CITATION_NO":"8185323","CITATION_ISSUE_DT":"06/14/2011","DOCKET_NO":"VA 2011-697","DECISION_DT":"11/25/2013","CFR_STANDARD_CODE":"77.208(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"873.00","sourceDate":"2011-06-14"},{"SOURCE_ROW_NUMBER":"363297","CITATION_NO":"8186072","CITATION_ISSUE_DT":"06/08/2011","DOCKET_NO":"VA 2011-697","DECISION_DT":"11/25/2013","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2901.00","DECISION_PENALTY_AMT":"2180.00","sourceDate":"2011-06-08"},{"SOURCE_ROW_NUMBER":"363363","CITATION_NO":"8179339","CITATION_ISSUE_DT":"05/19/2011","DOCKET_NO":"VA 2011-697","DECISION_DT":"11/25/2013","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1750.00","sourceDate":"2011-05-19"},{"SOURCE_ROW_NUMBER":"137028","CITATION_NO":"9870541","CITATION_ISSUE_DT":"04/05/2011","DOCKET_NO":"VA 2011-521","DECISION_DT":"09/12/2013","CFR_STANDARD_CODE":"70.100(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1569.00","DECISION_PENALTY_AMT":"1569.00","sourceDate":"2011-04-05"},{"SOURCE_ROW_NUMBER":"80655","CITATION_NO":"8179330","CITATION_ISSUE_DT":"04/05/2011","DOCKET_NO":"VA 2011-571","DECISION_DT":"10/25/2013","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1750.00","sourceDate":"2011-04-05"},{"SOURCE_ROW_NUMBER":"227240","CITATION_NO":"7319140","CITATION_ISSUE_DT":"03/03/2011","DOCKET_NO":"VA 2011-434","DECISION_DT":"11/20/2012","CFR_STANDARD_CODE":"49.12(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"4750.00","sourceDate":"2011-03-03"},{"SOURCE_ROW_NUMBER":"1845","CITATION_NO":"7319139","CITATION_ISSUE_DT":"03/03/2011","DOCKET_NO":"VA 2011-434","DECISION_DT":"11/20/2012","CFR_STANDARD_CODE":"49.50(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-03-03"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":841,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":199,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":12,"firstDate":"2002-03-07","lastDate":"2012-12-14","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":8},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":123,"firstDate":"2002-04-02","lastDate":"2013-03-26","metrics":{"inspectors":259,"recentRows":0,"onSiteHours":4646.25,"inspectionHours":7805.25,"inspectionSamples":662},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"310921","EVENT_NO":"4413745","INSPECTION_BEGIN_DT":"03/26/2013","INSPECTION_END_DT":"03/26/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2013-03-26"},{"SOURCE_ROW_NUMBER":"854756","EVENT_NO":"4413741","INSPECTION_BEGIN_DT":"10/02/2012","INSPECTION_END_DT":"12/18/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"206","SUM_TOTAL_ON_SITE_HOURS":"118","sourceDate":"2012-10-02"},{"SOURCE_ROW_NUMBER":"147142","EVENT_NO":"4413740","INSPECTION_BEGIN_DT":"09/25/2012","INSPECTION_END_DT":"09/26/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5.25","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"869095","EVENT_NO":"4413594","INSPECTION_BEGIN_DT":"08/29/2012","INSPECTION_END_DT":"09/20/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-08-29"},{"SOURCE_ROW_NUMBER":"552274","EVENT_NO":"4413590","INSPECTION_BEGIN_DT":"07/20/2012","INSPECTION_END_DT":"09/04/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"112.5","SUM_TOTAL_ON_SITE_HOURS":"68.75","sourceDate":"2012-07-20"},{"SOURCE_ROW_NUMBER":"757907","EVENT_NO":"4412551","INSPECTION_BEGIN_DT":"06/26/2012","INSPECTION_END_DT":"06/28/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2012-06-26"},{"SOURCE_ROW_NUMBER":"1072295","EVENT_NO":"4413480","INSPECTION_BEGIN_DT":"04/02/2012","INSPECTION_END_DT":"06/15/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"97.75","SUM_TOTAL_ON_SITE_HOURS":"59.75","sourceDate":"2012-04-02"},{"SOURCE_ROW_NUMBER":"471547","EVENT_NO":"4412539","INSPECTION_BEGIN_DT":"03/26/2012","INSPECTION_END_DT":"03/26/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2012-03-26"},{"SOURCE_ROW_NUMBER":"148978","EVENT_NO":"4412525","INSPECTION_BEGIN_DT":"01/26/2012","INSPECTION_END_DT":"03/26/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"160.75","SUM_TOTAL_ON_SITE_HOURS":"103","sourceDate":"2012-01-26"},{"SOURCE_ROW_NUMBER":"239219","EVENT_NO":"4412524","INSPECTION_BEGIN_DT":"01/24/2012","INSPECTION_END_DT":"01/24/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2012-01-24"},{"SOURCE_ROW_NUMBER":"223871","EVENT_NO":"4412522","INSPECTION_BEGIN_DT":"01/09/2012","INSPECTION_END_DT":"01/10/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.5","SUM_TOTAL_ON_SITE_HOURS":"9.75","sourceDate":"2012-01-09"},{"SOURCE_ROW_NUMBER":"78873","EVENT_NO":"4412293","INSPECTION_BEGIN_DT":"10/03/2011","INSPECTION_END_DT":"12/29/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"212.25","SUM_TOTAL_ON_SITE_HOURS":"125.75","sourceDate":"2011-10-03"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":75,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q4":{"hours":0,"employees":0,"production":0},"2012-Q3":{"hours":6548,"employees":14,"production":9952},"2012-Q2":{"hours":6925,"employees":15,"production":9952},"2012-Q1":{"hours":6743,"employees":14,"production":8851},"2011-Q4":{"hours":5198,"employees":17,"production":5370},"2011-Q3":{"hours":39842,"employees":58,"production":34535},"2011-Q2":{"hours":42108,"employees":60,"production":38032},"2011-Q1":{"hours":47435,"employees":54,"production":45594},"2010-Q4":{"hours":34178,"employees":58,"production":40323},"2010-Q3":{"hours":32379,"employees":60,"production":49312},"2010-Q2":{"hours":38267,"employees":59,"production":47253},"2010-Q1":{"hours":34259,"employees":55,"production":48128}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003":{"hours":7162,"employees":27,"production":10246},"2004":{"hours":55997,"employees":24,"production":81765},"2005":{"hours":56961,"employees":25,"production":113210},"2006":{"hours":66926,"employees":30,"production":129125},"2007":{"hours":91617,"employees":43,"production":142420},"2008":{"hours":101922,"employees":47,"production":178008},"2009":{"hours":121683,"employees":53,"production":187780},"2010":{"hours":139083,"employees":58,"production":185016},"2011":{"hours":134583,"employees":48,"production":123531},"2012":{"hours":20216,"employees":14,"production":28755}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":72,"firstDate":"2004-04-19","lastDate":"2012-08-03","metrics":{"recentRows":0,"doseOver100":10,"actDoseTotal":5068,"pelDoseTotal":3867},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"206224","EVENT_NO":"4413590","SURVEY_DATE":"08/03/2012","OCCUPATION_CD_DESC":"CAGE ATTENDANT/CAGER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2012-08-03"},{"SOURCE_ROW_NUMBER":"206223","EVENT_NO":"4413590","SURVEY_DATE":"07/31/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"55","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2012-07-31"},{"SOURCE_ROW_NUMBER":"206222","EVENT_NO":"4413590","SURVEY_DATE":"07/31/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"20","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2012-07-31"},{"SOURCE_ROW_NUMBER":"206221","EVENT_NO":"4413590","SURVEY_DATE":"07/31/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"27","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2012-07-31"},{"SOURCE_ROW_NUMBER":"206220","EVENT_NO":"4413590","SURVEY_DATE":"07/31/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"27","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2012-07-31"},{"SOURCE_ROW_NUMBER":"206219","EVENT_NO":"4413590","SURVEY_DATE":"07/31/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"32","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2012-07-31"},{"SOURCE_ROW_NUMBER":"206218","EVENT_NO":"4413480","SURVEY_DATE":"05/15/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"112","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"206217","EVENT_NO":"4413480","SURVEY_DATE":"05/15/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"51","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"206216","EVENT_NO":"4413480","SURVEY_DATE":"05/15/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"18","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"206215","EVENT_NO":"4413480","SURVEY_DATE":"05/15/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"21","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"206214","EVENT_NO":"4413480","SURVEY_DATE":"05/15/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"49","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"206208","EVENT_NO":"4412293","SURVEY_DATE":"11/01/2011","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"033","ACT_DOSE_85":"56","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2011-11-01"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":50,"firstDate":"2003-11-06","lastDate":"2011-07-14","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":8.4,"validSamples":47,"quartzPctTotal":213.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"48421","CASSETTE_NO":"57922871","SAMPLE_DT":"07/14/2011","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-07-14"},{"SOURCE_ROW_NUMBER":"72197","CASSETTE_NO":"57920886","SAMPLE_DT":"05/24/2011","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-24"},{"SOURCE_ROW_NUMBER":"155681","CASSETTE_NO":"57916758","SAMPLE_DT":"03/10/2011","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-10"},{"SOURCE_ROW_NUMBER":"141873","CASSETTE_NO":"57916756","SAMPLE_DT":"03/10/2011","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-10"},{"SOURCE_ROW_NUMBER":"99370","CASSETTE_NO":"51111230","SAMPLE_DT":"12/10/2010","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-12-10"},{"SOURCE_ROW_NUMBER":"134592","CASSETTE_NO":"57888687","SAMPLE_DT":"11/04/2010","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-11-04"},{"SOURCE_ROW_NUMBER":"54045","CASSETTE_NO":"57888522","SAMPLE_DT":"09/29/2010","QUARTZ_PCT":"00.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-09-29"},{"SOURCE_ROW_NUMBER":"95679","CASSETTE_NO":"51061706","SAMPLE_DT":"06/01/2010","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"165609","CASSETTE_NO":"51065456","SAMPLE_DT":"05/14/2010","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-05-14"},{"SOURCE_ROW_NUMBER":"155691","CASSETTE_NO":"57857577","SAMPLE_DT":"04/14/2010","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-04-14"},{"SOURCE_ROW_NUMBER":"74606","CASSETTE_NO":"57857542","SAMPLE_DT":"04/14/2010","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-04-14"},{"SOURCE_ROW_NUMBER":"163959","CASSETTE_NO":"57844953","SAMPLE_DT":"02/10/2010","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1064,"firstDate":"2003-10-08","lastDate":"2012-11-09","metrics":{"ss":321,"amountDue":438735,"contested":135,"amountPaid":431950.67,"recentRows":0,"section104d":3,"unterminated":1,"proposedPenalty":497219},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2398090","VIOLATION_NO":"8194671","VIOLATION_ISSUE_DT":"11/09/2012","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-11-09"},{"SOURCE_ROW_NUMBER":"2398089","VIOLATION_NO":"8194670","VIOLATION_ISSUE_DT":"11/09/2012","SIG_SUB":"Y","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2012-11-09"},{"SOURCE_ROW_NUMBER":"2398088","VIOLATION_NO":"8194669","VIOLATION_ISSUE_DT":"11/09/2012","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"127","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"N","sourceDate":"2012-11-09"},{"SOURCE_ROW_NUMBER":"2398131","VIOLATION_NO":"8202591","VIOLATION_ISSUE_DT":"10/26/2012","SIG_SUB":"N","PART_SECTION":"75.1100-2(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-26"},{"SOURCE_ROW_NUMBER":"2398130","VIOLATION_NO":"8202590","VIOLATION_ISSUE_DT":"10/25/2012","SIG_SUB":"N","PART_SECTION":"75.1505(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"7","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/26/2012","PROPOSED_PENALTY":"127","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"N","sourceDate":"2012-10-25"},{"SOURCE_ROW_NUMBER":"2398129","VIOLATION_NO":"8202589","VIOLATION_ISSUE_DT":"10/24/2012","SIG_SUB":"N","PART_SECTION":"75.1403-10(l)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/24/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-24"},{"SOURCE_ROW_NUMBER":"2398128","VIOLATION_NO":"8202588","VIOLATION_ISSUE_DT":"10/18/2012","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/18/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-18"},{"SOURCE_ROW_NUMBER":"2398127","VIOLATION_NO":"8202587","VIOLATION_ISSUE_DT":"10/18/2012","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/23/2012","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2012-10-18"},{"SOURCE_ROW_NUMBER":"2398126","VIOLATION_NO":"8202586","VIOLATION_ISSUE_DT":"10/17/2012","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/18/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"2398125","VIOLATION_NO":"8202585","VIOLATION_ISSUE_DT":"10/17/2012","SIG_SUB":"N","SECTION_OF_ACT":"316(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2012","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"2398124","VIOLATION_NO":"8202584","VIOLATION_ISSUE_DT":"10/17/2012","SIG_SUB":"N","PART_SECTION":"75.1714-7(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/17/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"2398123","VIOLATION_NO":"8202583","VIOLATION_ISSUE_DT":"10/17/2012","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/17/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-17"}]}],"safety":{"href":"/api/v1/mines/4407046/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4407046/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-10","heading":"Criteria—Haulage; general.","id":"75.1403-10","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-10","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) A permissible trip light or other approved device such as reflectors, approved by the Coal Mine Safety District Manager(s), should be used on the rear of trips pulled, on the front of trips pushed and on trips lowered in slopes. However, trip lights or other approved devices need not be used on cars being shifted to and from loading machines, on cars being handled at loading heads, during gathering operations at working faces, when trailing locomotives are used, or on trips pulled by animals.\n\n(b) Cars on main haulage roads should not be pushed, except where necessary to push cars from side tracks located near the working section to the producing entries and rooms, where necessary to clear switches and sidetracks, and on the approach to cages, slopes, and surface inclines.\n\n(c) Warning lights or reflective signs or tapes should be installed along haulage roads at locations of abrupt or sudden changes in the overhead clearance.\n\n(d) No person, other than the motorman and brakeman, should ride on a locomotive unless authorized by the mine foreman, and then only when safe riding facilities are provided. No person should ride on any loaded car or on the bumper of any car. However, the brakeman may ride on the rear bumper of the last car of a slow moving trip pulled by a locomotive.\n\n(e) Positive-acting stopblocks or derails should be used where necessary to protect persons from danger of runaway haulage equipment.\n\n(f) An audible warning should be given by the operator of all self-propelled equipment including off-track equipment, where persons may be endangered by the movement of the equipment.\n\n(g) Locomotives and personnel carriers should not approach to within 300 feet of preceding haulage equipment, except trailing locomotives that are an integral part of the trip.\n\n(h) A total of at least 36 inches of unobstructed side clearance (both sides combined) should be provided for all rubber-tired haulage equipment where such equipment is used.\n\n(i) Off-track haulage roadways should be maintained as free as practicable from bottom irregularities, debris, and wet or muddy conditions that affect the control of the equipment.\n\n(j) Operators of self-propelled equipment should face in the direction of travel.\n\n(k) Mechanical steering and control devices should be maintained so as to provide positive control at all times.\n\n(l) All self-propelled rubber-tired haulage equipment should be equipped with well maintained brakes, lights, and a warning device.\n\n(m) On and after March 30, 1971, all tram control switches on rubber-tired equipment should be designed to provide automatic return to the stop or off position when released.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Multi-gas detectors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-7","part":"75","subchapter":"O","subpart":"R","id":"75.1714-7","citation":"30 CFR 75.1714-7","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4407046","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}