{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4407014","name":"Mine No 1","status":"Abandoned and Sealed","status_date":"2007-03-08","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Buchanan","nearest_town":"Hurley","operator_id":"0052632","operator_name":"Cavalier Mineral Inc","controller_id":"C00283","controller_name":"Gary  Dotson","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.458333,"longitude":-82.079166},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1113},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4407014","name":"Mine No 1"},"operator":{"type":"operator","id":"0052632","name":"Cavalier Mineral Inc"},"controller":{"type":"controller","id":"C00283","name":"Gary  Dotson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15772","name":"Carl  Mullins"},"object":{"type":"mine","id":"4407014","name":"Mine No 1"},"validFrom":"1998-12-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|C15772|1998-12-10|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15967","name":"Terry E  Matney"},"object":{"type":"mine","id":"4407014","name":"Mine No 1"},"validFrom":"2000-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|C15967|2000-08-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24473","name":"Matney Construction Company Inc"},"object":{"type":"mine","id":"4407014","name":"Mine No 1"},"validFrom":"2000-11-01","validTo":"2001-03-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|P24473|2000-11-01|2001-03-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15967","name":"Terry E  Matney"},"object":{"type":"operator","id":"P24473","name":"Matney Construction Company Inc"},"validFrom":"2000-11-01","validTo":"2001-03-25","current":false,"derived":true,"evidenceMineId":"4407014","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|P24473|2000-11-01|C15967|2000-08-01|97871"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24050","name":"Minchar Coal Company"},"object":{"type":"mine","id":"4407014","name":"Mine No 1"},"validFrom":"2001-03-26","validTo":"2004-05-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|P24050|2001-03-26|2004-05-12"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15772","name":"Carl  Mullins"},"object":{"type":"operator","id":"P24050","name":"Minchar Coal Company"},"validFrom":"2001-03-26","validTo":"2004-05-12","current":false,"derived":true,"evidenceMineId":"4407014","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|P24050|2001-03-26|C15772|1998-12-10|96729"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0052632","name":"Cavalier Mineral Inc"},"object":{"type":"mine","id":"4407014","name":"Mine No 1"},"validFrom":"2004-05-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|0052632|2004-05-13|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00283","name":"Gary  Dotson  et al"},"object":{"type":"mine","id":"4407014","name":"Mine No 1"},"validFrom":"2004-05-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|C00283|2004-05-13|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00283","name":"Gary  Dotson  et al"},"object":{"type":"operator","id":"0052632","name":"Cavalier Mineral Inc"},"validFrom":"2004-05-13","validTo":null,"current":true,"derived":true,"evidenceMineId":"4407014","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4407014|0052632|2004-05-13|C00283|2004-05-13|45733"}}],"coverage":{"historyRecords":3,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":18,"firstDate":"2001-05-24","lastDate":"2006-09-12","metrics":{"daysLost":640,"injuries":18,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"29126","DOCUMENT_NO":"220062650036","ACCIDENT_DT":"09/12/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"188","NARRATIVE":"Rib rolled off striking employee across right shoulder and back.","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"205495","DOCUMENT_NO":"220060240055","ACCIDENT_DT":"01/11/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE said before shift started he was hurting in groin area and stomach while operating the 21sc shuttle car when he hit a hole in the roadway that made him hurt worse.","sourceDate":"2006-01-11"},{"SOURCE_ROW_NUMBER":"102051","DOCUMENT_NO":"220052100040","ACCIDENT_DT":"07/21/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"THERE WAS A ROCK IN THE FEEDER.  EE WAS GOING TO GET THE ROCK OUT.  SUPERVISOR WAS GOING TO MOVE SCOOP OUT OF THE WAY AND THERE WAS A MISCOMMUNICATION.  EE GOT IN THE FEEDER WHILE SUPERVISOR WAS MOVING SCOOP AND THE SCOOP GOT HIS ANKLE.","sourceDate":"2005-07-21"},{"SOURCE_ROW_NUMBER":"214132","DOCUMENT_NO":"220051320044","ACCIDENT_DT":"05/02/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE had a 930 cat loader brake head in his vehicle when he went to get the brake head out of the vehicle he pulled a muscle in his lower back.","sourceDate":"2005-05-02"},{"SOURCE_ROW_NUMBER":"54882","DOCUMENT_NO":"220042430053","ACCIDENT_DT":"08/23/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"INJURED EMPLOYEE WAS TRYING TO GET A PIECE OF ROCK OFF MINER WITH A SLATE BAR WHILE TRYING TO GET THE ROCK OFF MINER HE FELT OR HEARD SOMETHING TEAR IN HIS LOWER BACK.","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"257153","DOCUMENT_NO":"220040820061","ACCIDENT_DT":"03/11/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating shuttle car when rock flew up and hit him in the mouth causing a laceration to his lip and chipped a tooth.","sourceDate":"2004-03-11"},{"SOURCE_ROW_NUMBER":"42027","DOCUMENT_NO":"220040820062","ACCIDENT_DT":"03/10/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee was operating shuttle car when rock fell and hit him on the right shoulder and side of face causing a contusion and sprained neck.","sourceDate":"2004-03-10"},{"SOURCE_ROW_NUMBER":"244247","DOCUMENT_NO":"220033110032","ACCIDENT_DT":"10/27/2003","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","NARRATIVE":"EE LIFTED ROCK FROM BELTLINE, FELT PAIN IN HIS STOMACH, CAUSING AN ABDOMINAL WALL MUSCLE STRAIN.","sourceDate":"2003-10-27"},{"SOURCE_ROW_NUMBER":"37796","DOCUMENT_NO":"220033110033","ACCIDENT_DT":"09/24/2003","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE BUMPED HEAD ON BROW OF ROOF INSIDE MINE CAUSING PAIN IN THE NECK.","sourceDate":"2003-09-24"},{"SOURCE_ROW_NUMBER":"80744","DOCUMENT_NO":"220032400064","ACCIDENT_DT":"08/18/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE WAS LIFTING SIDE RAIL OF MINER AND FELL ON HIS RIGHT FOOT.","sourceDate":"2003-08-18"},{"SOURCE_ROW_NUMBER":"252846","DOCUMENT_NO":"220031500031","ACCIDENT_DT":"05/19/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EE WAS LIFTING BOX OF GLUE AND STRAINED LEFT SHOULDER","sourceDate":"2003-05-19"},{"SOURCE_ROW_NUMBER":"127844","DOCUMENT_NO":"220030170028","ACCIDENT_DT":"01/07/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"EE WAS HANGING VENTILATION CURTAIN, HIS FOOT WAS STICKING OUT FROM UNDERNEATH CURTAIN, PINNER RAN OVER RIGHT FOOT CAUSING CONTUSION.","sourceDate":"2003-01-07"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-03-08","lastDate":"2007-03-08","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":157,"firstDate":"2001-05-01","lastDate":"2006-12-12","metrics":{"ss":49,"delinquent":157,"recentRows":0,"paidPenalty":12647.57,"proposedPenalty":12648,"currentAssessment":12648},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"881352","VIOLATION_NO":"7318643","ISSUE_DT":"12/12/2006","CFR_STANDARD_CD":"75.380(d)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"881351","VIOLATION_NO":"7318633","ISSUE_DT":"12/05/2006","CFR_STANDARD_CD":"75.1714-2(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-12-05"},{"SOURCE_ROW_NUMBER":"881350","VIOLATION_NO":"7318632","ISSUE_DT":"12/05/2006","CFR_STANDARD_CD":"75.206(e)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"135.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-12-05"},{"SOURCE_ROW_NUMBER":"916202","VIOLATION_NO":"7317067","ISSUE_DT":"10/12/2006","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"914181","VIOLATION_NO":"7316530","ISSUE_DT":"09/21/2006","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-21"},{"SOURCE_ROW_NUMBER":"914180","VIOLATION_NO":"7316529","ISSUE_DT":"09/20/2006","CFR_STANDARD_CD":"75.602","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"914953","VIOLATION_NO":"7316493","ISSUE_DT":"06/26/2006","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"914952","VIOLATION_NO":"7316492","ISSUE_DT":"06/26/2006","CFR_STANDARD_CD":"75.1714-2(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"914951","VIOLATION_NO":"7316491","ISSUE_DT":"06/22/2006","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-22"},{"SOURCE_ROW_NUMBER":"914950","VIOLATION_NO":"7316490","ISSUE_DT":"06/22/2006","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-22"},{"SOURCE_ROW_NUMBER":"914949","VIOLATION_NO":"7316489","ISSUE_DT":"06/21/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"914948","VIOLATION_NO":"7316488","ISSUE_DT":"06/19/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-19"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":466,"firstDate":"2001-05-24","lastDate":"2006-12-12","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":10,"validSamples":456,"maxConcentration":4.594,"concentrationTotal":319.513},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1160092","CASS_NUM":"57661602","SMP_TAKEN_DT":"12/12/2006","CONC":".04","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"1032709","CASS_NUM":"57661594","SMP_TAKEN_DT":"12/12/2006","CONC":".189","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"900126","CASS_NUM":"57661627","SMP_TAKEN_DT":"12/12/2006","CONC":".411","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"591366","CASS_NUM":"57661621","SMP_TAKEN_DT":"12/12/2006","CONC":".769","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"91445","CASS_NUM":"57661632","SMP_TAKEN_DT":"12/12/2006","CONC":".754","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"1636874","CASS_NUM":"50797773","SMP_TAKEN_DT":"10/3/2006","CONC":".465","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-03"},{"SOURCE_ROW_NUMBER":"940911","CASS_NUM":"50797769","SMP_TAKEN_DT":"10/3/2006","CONC":".18","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-03"},{"SOURCE_ROW_NUMBER":"1655457","CASS_NUM":"50797709","SMP_TAKEN_DT":"10/2/2006","CONC":".617","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-02"},{"SOURCE_ROW_NUMBER":"267482","CASS_NUM":"50797728","SMP_TAKEN_DT":"9/30/2006","CONC":".431","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-30"},{"SOURCE_ROW_NUMBER":"191956","CASS_NUM":"50797772","SMP_TAKEN_DT":"9/29/2006","CONC":".662","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-29"},{"SOURCE_ROW_NUMBER":"57985","CASS_NUM":"50797732","SMP_TAKEN_DT":"9/28/2006","CONC":".693","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1618935","CASS_NUM":"57610032","SMP_TAKEN_DT":"9/18/2006","CONC":".444","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-18"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":4,"firstDate":"2001-07-12","lastDate":"2007-02-22","metrics":{"linkedIssuances":4},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":27,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":9,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2000-11-01","lastDate":"2004-05-13","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":110,"firstDate":"2001-01-24","lastDate":"2007-02-08","metrics":{"inspectors":141,"recentRows":0,"onSiteHours":1442.5,"inspectionHours":2586.75,"inspectionSamples":36},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1138166","EVENT_NO":"4402308","INSPECTION_BEGIN_DT":"02/08/2007","INSPECTION_END_DT":"03/08/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2007-02-08"},{"SOURCE_ROW_NUMBER":"565044","EVENT_NO":"4153965","INSPECTION_BEGIN_DT":"12/12/2006","INSPECTION_END_DT":"12/28/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"60","SUM_TOTAL_ON_SITE_HOURS":"41.75","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"27702","EVENT_NO":"4128132","INSPECTION_BEGIN_DT":"12/05/2006","INSPECTION_END_DT":"01/08/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20.75","SUM_TOTAL_ON_SITE_HOURS":"11.75","sourceDate":"2006-12-05"},{"SOURCE_ROW_NUMBER":"78289","EVENT_NO":"4153962","INSPECTION_BEGIN_DT":"10/12/2006","INSPECTION_END_DT":"10/12/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.25","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"308984","EVENT_NO":"4153515","INSPECTION_BEGIN_DT":"09/18/2006","INSPECTION_END_DT":"09/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"63","SUM_TOTAL_ON_SITE_HOURS":"45.5","sourceDate":"2006-09-18"},{"SOURCE_ROW_NUMBER":"458074","EVENT_NO":"4153710","INSPECTION_BEGIN_DT":"05/18/2006","INSPECTION_END_DT":"06/27/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"163.5","SUM_TOTAL_ON_SITE_HOURS":"95","sourceDate":"2006-05-18"},{"SOURCE_ROW_NUMBER":"1116792","EVENT_NO":"4154593","INSPECTION_BEGIN_DT":"01/03/2006","INSPECTION_END_DT":"02/28/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"131.75","SUM_TOTAL_ON_SITE_HOURS":"76","sourceDate":"2006-01-03"},{"SOURCE_ROW_NUMBER":"1101527","EVENT_NO":"4402038","INSPECTION_BEGIN_DT":"12/21/2005","INSPECTION_END_DT":"01/26/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-12-21"},{"SOURCE_ROW_NUMBER":"39739","EVENT_NO":"4154583","INSPECTION_BEGIN_DT":"10/03/2005","INSPECTION_END_DT":"12/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"107","SUM_TOTAL_ON_SITE_HOURS":"63.75","sourceDate":"2005-10-03"},{"SOURCE_ROW_NUMBER":"164531","EVENT_NO":"4402079","INSPECTION_BEGIN_DT":"09/13/2005","INSPECTION_END_DT":"09/29/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"48.5","SUM_TOTAL_ON_SITE_HOURS":"34.5","sourceDate":"2005-09-13"},{"SOURCE_ROW_NUMBER":"409881","EVENT_NO":"4153156","INSPECTION_BEGIN_DT":"07/14/2005","INSPECTION_END_DT":"10/03/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-07-14"},{"SOURCE_ROW_NUMBER":"538366","EVENT_NO":"4153153","INSPECTION_BEGIN_DT":"07/05/2005","INSPECTION_END_DT":"07/11/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2005-07-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":39,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q1":{"hours":552,"employees":8,"production":2905},"2006-Q4":{"hours":4058,"employees":18,"production":9764},"2006-Q3":{"hours":5754,"employees":14,"production":25320},"2006-Q1":{"hours":5574,"employees":14,"production":14521},"2005-Q4":{"hours":6860,"employees":16,"production":11068},"2005-Q3":{"hours":6684,"employees":14,"production":14970},"2005-Q2":{"hours":7416,"employees":14,"production":16775},"2005-Q1":{"hours":8349,"employees":13,"production":19656},"2004-Q3":{"hours":5737,"employees":14,"production":15723},"2004-Q1":{"hours":0,"employees":0,"production":0},"2003-Q4":{"hours":0,"employees":0,"production":0},"2003-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":15958,"employees":9,"production":36262},"2002":{"hours":10980,"employees":15,"production":27839},"2004":{"hours":5737,"employees":14,"production":15723},"2005":{"hours":29309,"employees":14,"production":62469},"2006":{"hours":15386,"employees":15,"production":49605},"2007":{"hours":552,"employees":8,"production":2905}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":39,"firstDate":"2001-09-10","lastDate":"2006-02-23","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":2160,"pelDoseTotal":1534},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"205392","EVENT_NO":"4154593","SURVEY_DATE":"02/23/2006","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"27","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2006-02-23"},{"SOURCE_ROW_NUMBER":"205391","EVENT_NO":"4154593","SURVEY_DATE":"02/23/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"27","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2006-02-23"},{"SOURCE_ROW_NUMBER":"205390","EVENT_NO":"4154593","SURVEY_DATE":"02/23/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"70","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2006-02-23"},{"SOURCE_ROW_NUMBER":"205389","EVENT_NO":"4154593","SURVEY_DATE":"02/23/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"07","MANUFACTURER_CD":"058","ACT_DOSE_85":"60","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2006-02-23"},{"SOURCE_ROW_NUMBER":"205388","EVENT_NO":"4154583","SURVEY_DATE":"12/01/2005","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"7","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"205381","EVENT_NO":"4153059","SURVEY_DATE":"01/25/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"033","ACT_DOSE_85":"26","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"205380","EVENT_NO":"4153059","SURVEY_DATE":"01/25/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"44","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"205379","EVENT_NO":"4153059","SURVEY_DATE":"01/25/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"45","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"205378","EVENT_NO":"4153059","SURVEY_DATE":"01/25/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"033","ACT_DOSE_85":"38","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"205377","EVENT_NO":"4153059","SURVEY_DATE":"01/25/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"56","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"205387","EVENT_NO":"4153276","SURVEY_DATE":"09/16/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"71","PEL_DOSE_90":"61","SURVEY_TYPE":"F","sourceDate":"2004-09-16"},{"SOURCE_ROW_NUMBER":"205386","EVENT_NO":"4153272","SURVEY_DATE":"08/25/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"246","PEL_DOSE_90":"221","SURVEY_TYPE":"I","sourceDate":"2004-08-25"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":69,"firstDate":"2001-05-30","lastDate":"2006-12-12","metrics":{"recentRows":0,"voidSamples":4,"maxQuartzPct":40,"validSamples":65,"quartzPctTotal":471.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"28752","CASSETTE_NO":"57661621","SAMPLE_DT":"12/12/2006","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"20370","CASSETTE_NO":"57610032","SAMPLE_DT":"09/18/2006","QUARTZ_PCT":"08.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-09-18"},{"SOURCE_ROW_NUMBER":"36283","CASSETTE_NO":"57610213","SAMPLE_DT":"06/20/2006","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-20"},{"SOURCE_ROW_NUMBER":"99295","CASSETTE_NO":"57609411","SAMPLE_DT":"02/08/2006","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"69534","CASSETTE_NO":"57609382","SAMPLE_DT":"02/08/2006","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-08"},{"SOURCE_ROW_NUMBER":"46267","CASSETTE_NO":"57609669","SAMPLE_DT":"01/04/2006","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-01-04"},{"SOURCE_ROW_NUMBER":"56755","CASSETTE_NO":"57561326","SAMPLE_DT":"11/17/2005","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-17"},{"SOURCE_ROW_NUMBER":"38955","CASSETTE_NO":"57561381","SAMPLE_DT":"11/17/2005","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-17"},{"SOURCE_ROW_NUMBER":"130418","CASSETTE_NO":"57543812","SAMPLE_DT":"09/13/2005","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-13"},{"SOURCE_ROW_NUMBER":"122112","CASSETTE_NO":"57543782","SAMPLE_DT":"09/13/2005","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-13"},{"SOURCE_ROW_NUMBER":"50982","CASSETTE_NO":"57543799","SAMPLE_DT":"09/13/2005","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-13"},{"SOURCE_ROW_NUMBER":"72866","CASSETTE_NO":"57530084","SAMPLE_DT":"06/21/2005","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-06-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":158,"firstDate":"2001-05-01","lastDate":"2006-12-12","metrics":{"ss":49,"amountDue":12648,"contested":0,"amountPaid":12647.57,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":12648},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2393152","VIOLATION_NO":"7318643","VIOLATION_ISSUE_DT":"12/12/2006","SIG_SUB":"N","PART_SECTION":"75.380(d)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/20/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-12-12"},{"SOURCE_ROW_NUMBER":"2393151","VIOLATION_NO":"7318633","VIOLATION_ISSUE_DT":"12/05/2006","SIG_SUB":"N","PART_SECTION":"75.1714-2(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-12-05"},{"SOURCE_ROW_NUMBER":"2393150","VIOLATION_NO":"7318632","VIOLATION_ISSUE_DT":"12/05/2006","SIG_SUB":"Y","PART_SECTION":"75.206(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/05/2006","PROPOSED_PENALTY":"135","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2006-12-05"},{"SOURCE_ROW_NUMBER":"2393138","VIOLATION_NO":"7317067","VIOLATION_ISSUE_DT":"10/12/2006","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/12/2006","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"2393110","VIOLATION_NO":"7316530","VIOLATION_ISSUE_DT":"09/21/2006","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2006","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2006-09-21"},{"SOURCE_ROW_NUMBER":"2393109","VIOLATION_NO":"7316529","VIOLATION_ISSUE_DT":"09/20/2006","SIG_SUB":"N","PART_SECTION":"75.602","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/21/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"2393076","VIOLATION_NO":"7316493","VIOLATION_ISSUE_DT":"06/26/2006","SIG_SUB":"Y","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/27/2006","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"2393075","VIOLATION_NO":"7316492","VIOLATION_ISSUE_DT":"06/26/2006","SIG_SUB":"N","PART_SECTION":"75.1714-2(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"2393074","VIOLATION_NO":"7316491","VIOLATION_ISSUE_DT":"06/22/2006","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"59.57","CONTESTED_IND":"N","sourceDate":"2006-06-22"},{"SOURCE_ROW_NUMBER":"2393073","VIOLATION_NO":"7316490","VIOLATION_ISSUE_DT":"06/22/2006","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-22"},{"SOURCE_ROW_NUMBER":"2393072","VIOLATION_NO":"7316489","VIOLATION_ISSUE_DT":"06/21/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"2393071","VIOLATION_NO":"7316488","VIOLATION_ISSUE_DT":"06/19/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/20/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-19"}]}],"safety":{"href":"/api/v1/mines/4407014/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4407014/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; use and location requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-2","part":"75","subchapter":"O","subpart":"R","id":"75.1714-2","citation":"30 CFR 75.1714-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.206","heading":"Conventional roof support.","id":"75.206","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.206","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) Except in anthracite mines using non-mechanized mining systems, when conventional roof support materials are used as the only means of support—\n\n(1) The width of any opening shall not exceed 20 feet;\n\n(2) The spacing of roadway roof support shall not exceed 5 feet;\n\n(3)(i) Supports shall be installed to within 5 feet of the uncut face;\n\n(ii) When supports nearest the face must be removed to facilitate the operation of face equipment, equivalent temporary support shall be installed prior to removing the supports;\n\n(4) Straight roadways shall not exceed 16 feet wide where full overhead support is used and 14 feet wide where only posts are used;\n\n(5) Curved roadways shall not exceed 16 feet wide; and\n\n(6) The roof at the entrance of all openings along travelways which are no longer needed for storing supplies or for travel of equipment shall be supported by extending the line of support across the opening.\n\n(b) Conventional roof support materials shall meet the following specifications:\n\n(1) The minimum diameter of cross-sectional area of wooden posts shall be as follows:\n\nPost length (in inches) Diameter of round posts (in inches) Cross-sectional area of split posts (in square inches) 60 or less 4 13 Over 60 to 84 5 20 Over 84 to 108 6 28 Over 108 to 132 7 39 Over 132 to 156 8 50 Over 156 to 180 9 64 Over 180 to 204 10 79 Over 204 to 228 11 95 Over 228 12 113\n\n(2) Wooden materials used for support shall have the following dimensions:\n\n(i) Cap blocks and footings shall have flat sides and be at least 2 inches thick, 4 inches wide and 12 inches long.\n\n(ii) Crossbars shall have a minimum cross-sectional area of 24 square inches and be at least 3 inches thick.\n\n(iii) Planks shall be at least 6 inches wide and 1 inch thick.\n\n(3) Cribbing materials shall have at least two parallel flat sides.\n\n(c) A cluster of two or more posts that provide equivalent strength may be used to meet the requirements of paragraph (b)(1) of this section, except that no post shall have a diameter less than 4 inches or have a cross-sectional area less than 13 square inches.\n\n(d) Materials other than wood used for support shall have support strength at least equivalent to wooden material meeting the applicable provisions of this section.\n\n(e) Posts and jacks shall be tightly installed on solid footing.\n\n(f) When posts are installed under roof susceptible to sloughing a cap block, plank, crossbar or materials that are equally effective shall be placed between the post and the roof.\n\n(g) Blocks used for lagging between the roof and crossbars shall be spaced to distribute the load.\n\n(h) Jacks used for roof support shall be used with at least 36 square inches of roof bearing surface.\n\n[53 FR 2375, Jan. 27, 1988, as amended at 55 FR 14228, Apr. 16, 1990; 55 FR 20137, May 15, 1990]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","heading":"Trailing cable junctions.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.602","part":"75","subchapter":"O","subpart":"G","id":"75.602","citation":"30 CFR 75.602","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4407014","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}