{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4406974","name":"Mine No 3","status":"Abandoned and Sealed","status_date":"2004-07-31","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Buchanan","nearest_town":"Big Rock","operator_id":"P22943","operator_name":"A B & J Coal Company Inc","controller_id":"C07671","controller_name":"Susie A  Smith; Elmer  Fuller","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.318333,"longitude":-82.214166},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":650},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406974","name":"Mine No 3"},"operator":{"type":"operator","id":"P22943","name":"A B & J Coal Company Inc"},"controller":{"type":"controller","id":"C07671","name":"Susie A  Smith; Elmer  Fuller"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07671","name":"Susie A  Smith et al"},"object":{"type":"mine","id":"4406974","name":"Mine No 3"},"validFrom":"1994-09-06","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406974|C07671|1994-09-06|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22943","name":"A B & J Coal Company Inc"},"object":{"type":"mine","id":"4406974","name":"Mine No 3"},"validFrom":"1999-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406974|P22943|1999-12-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07671","name":"Susie A  Smith et al"},"object":{"type":"operator","id":"P22943","name":"A B & J Coal Company Inc"},"validFrom":"1999-12-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406974","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406974|P22943|1999-12-01|C07671|1994-09-06|75354"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07671","name":"Elmer  Fuller et al"},"object":{"type":"operator","id":"P22943","name":"A B & J Coal Company Inc"},"validFrom":"1999-12-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406974","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406974|P22943|1999-12-01|C07671|1994-09-06|75355"}}],"coverage":{"historyRecords":2,"edgeCount":4,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":7,"firstDate":"2000-03-27","lastDate":"2002-10-08","metrics":{"daysLost":164,"injuries":7,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"205488","DOCUMENT_NO":"220022880052","ACCIDENT_DT":"10/08/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"93","NARRATIVE":"VICTIM WAS HELPING DRILL ANCHOR HOLES FOR SECTION TAILPIECE WHILE DRILL WAS IN MOTION HE REALLED DOWN TOCLEAN DUST FROM HOLE DRILL STEEL CAUGHT HIS SHIRT GLEEVE AND WRAPPED UP IN STEEL RESULTI NG IN FRACTURE TO RT FOREARM.","sourceDate":"2002-10-08"},{"SOURCE_ROW_NUMBER":"227019","DOCUMENT_NO":"220021190064","ACCIDENT_DT":"04/10/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"60","NARRATIVE":"EE WAS HELPING THE REST OF THE EES TO ADVANCE THE BELT WHEN HE TRIPPED & FELL STRIKING HIS KNEE ON THE MINE FLOOR.","sourceDate":"2002-04-10"},{"SOURCE_ROW_NUMBER":"37788","DOCUMENT_NO":"220012390139","ACCIDENT_DT":"08/15/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EMPLOYEE WAS HANGING MINER CABLE AND WATERLINE IN #3 ENTRY WITH OTHER EE. HE SAID LATER HE FELT STOMACH AND BACK HURTING.","sourceDate":"2001-08-15"},{"SOURCE_ROW_NUMBER":"269999","DOCUMENT_NO":"220010160111","ACCIDENT_DT":"01/05/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"VICTIM WAS INSTALLING ROOF BOLTS IN #4 ENTRY RT. XCUT WHEN HE SET PERSONAL CANOPY AGAINST MINE ROOF THE BOTTOM PLATE THAT SUPPORTS THE JACK BROKE, CAUSING IT BREAK LETTING THE CANOPY TO FALL S TRIKING HIM THE HEAD & STOVING HIS NECK UP.","sourceDate":"2001-01-05"},{"SOURCE_ROW_NUMBER":"257143","DOCUMENT_NO":"220010100005","ACCIDENT_DT":"01/01/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","NARRATIVE":"VICTIM WAS CRAWLING WHEN SCOOP TRAMED BY RUNNING OVER LUMP OF COAL LUMP OF COAL FLIPPED OFF SCOOP TIRE HITTING HIM IN LEFT EYE.","sourceDate":"2001-01-01"},{"SOURCE_ROW_NUMBER":"188226","DOCUMENT_NO":"220002240047","ACCIDENT_DT":"08/02/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"VICTIM PLACED HAND ON DRILL FRAME OF PINNER WHILE LETTING IT DOWN CAUGHT HIS RT. THUMB MASHING IT.","sourceDate":"2000-08-02"},{"SOURCE_ROW_NUMBER":"149623","DOCUMENT_NO":"220001010075","ACCIDENT_DT":"03/27/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","NARRATIVE":"REMOVING TINE FROM ROOF BOLTER WITH RATCHET & SOCKET. LOOSENING LUG NUTS WHEN RATCHET SLIPPED & SOCKET BUSTED CAUSING VICTIM TO STRIKE BOLTER FACE FIRST CAUSING LACERATION ABOVE RIGHT EYEBROW REQUIRING 5 STITCHES.","sourceDate":"2000-03-27"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-07-31","lastDate":"2004-07-31","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":65,"firstDate":"2000-02-03","lastDate":"2003-04-28","metrics":{"ss":26,"delinquent":65,"recentRows":0,"paidPenalty":4941,"proposedPenalty":4941,"currentAssessment":4941},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"912530","VIOLATION_NO":"7332034","ISSUE_DT":"04/28/2003","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-28"},{"SOURCE_ROW_NUMBER":"912529","VIOLATION_NO":"7332031","ISSUE_DT":"04/16/2003","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-16"},{"SOURCE_ROW_NUMBER":"912528","VIOLATION_NO":"7332030","ISSUE_DT":"04/16/2003","CFR_STANDARD_CD":"75.523-3(b)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-16"},{"SOURCE_ROW_NUMBER":"912527","VIOLATION_NO":"7332029","ISSUE_DT":"04/16/2003","CFR_STANDARD_CD":"75.523-2(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-16"},{"SOURCE_ROW_NUMBER":"912526","VIOLATION_NO":"7332027","ISSUE_DT":"04/08/2003","CFR_STANDARD_CD":"75.325(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-08"},{"SOURCE_ROW_NUMBER":"912459","VIOLATION_NO":"7325414","ISSUE_DT":"02/11/2003","CFR_STANDARD_CD":"77.410(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"66.00","CURRENT_ASSESSMENT_AMT":"66.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-02-11"},{"SOURCE_ROW_NUMBER":"912458","VIOLATION_NO":"7325413","ISSUE_DT":"02/04/2003","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-02-04"},{"SOURCE_ROW_NUMBER":"912457","VIOLATION_NO":"7325412","ISSUE_DT":"02/04/2003","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-02-04"},{"SOURCE_ROW_NUMBER":"912456","VIOLATION_NO":"7325410","ISSUE_DT":"01/31/2003","CFR_STANDARD_CD":"75.1107","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-31"},{"SOURCE_ROW_NUMBER":"909926","VIOLATION_NO":"7325508","ISSUE_DT":"12/31/2002","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"909925","VIOLATION_NO":"7325507","ISSUE_DT":"12/17/2002","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-12-17"},{"SOURCE_ROW_NUMBER":"909924","VIOLATION_NO":"7325505","ISSUE_DT":"12/17/2002","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-12-17"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":247,"firstDate":"2000-02-17","lastDate":"2003-05-22","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":21,"validSamples":226,"maxConcentration":5.026,"concentrationTotal":91.001},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1429831","CASS_NUM":"50693017","SMP_TAKEN_DT":"5/22/2003","CONC":"1.372","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"132679","CASS_NUM":"50693020","SMP_TAKEN_DT":"4/30/2003","CONC":"5.026","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-04-30"},{"SOURCE_ROW_NUMBER":"944085","CASS_NUM":"50693069","SMP_TAKEN_DT":"4/29/2003","CONC":"1.497","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-04-29"},{"SOURCE_ROW_NUMBER":"277269","CASS_NUM":"50676573","SMP_TAKEN_DT":"4/28/2003","CONC":".866","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-04-28"},{"SOURCE_ROW_NUMBER":"183780","CASS_NUM":"50676594","SMP_TAKEN_DT":"4/26/2003","CONC":"2.538","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-04-26"},{"SOURCE_ROW_NUMBER":"1019587","CASS_NUM":"50693029","SMP_TAKEN_DT":"4/25/2003","CONC":"2.169","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-04-25"},{"SOURCE_ROW_NUMBER":"1208649","CASS_NUM":"50693030","SMP_TAKEN_DT":"4/24/2003","CONC":".481","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-04-24"},{"SOURCE_ROW_NUMBER":"469566","CASS_NUM":"50692984","SMP_TAKEN_DT":"3/28/2003","CONC":".138","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-03-28"},{"SOURCE_ROW_NUMBER":"121852","CASS_NUM":"50676610","SMP_TAKEN_DT":"2/24/2003","CONC":".408","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-02-24"},{"SOURCE_ROW_NUMBER":"1097336","CASS_NUM":"50676602","SMP_TAKEN_DT":"2/21/2003","CONC":".296","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-02-21"},{"SOURCE_ROW_NUMBER":"1138888","CASS_NUM":"50693008","SMP_TAKEN_DT":"2/20/2003","CONC":".346","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-02-20"},{"SOURCE_ROW_NUMBER":"84901","CASS_NUM":"50693027","SMP_TAKEN_DT":"2/19/2003","CONC":".764","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-02-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":81,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":17,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1999-12-01","lastDate":"1999-12-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":85,"firstDate":"2000-01-06","lastDate":"2004-07-23","metrics":{"inspectors":96,"recentRows":0,"onSiteHours":782.75,"inspectionHours":1377.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1026429","EVENT_NO":"4153040","INSPECTION_BEGIN_DT":"07/23/2004","INSPECTION_END_DT":"07/27/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2004-07-23"},{"SOURCE_ROW_NUMBER":"603917","EVENT_NO":"4153261","INSPECTION_BEGIN_DT":"06/09/2004","INSPECTION_END_DT":"06/09/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"106370","EVENT_NO":"4150842","INSPECTION_BEGIN_DT":"01/16/2004","INSPECTION_END_DT":"01/19/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-01-16"},{"SOURCE_ROW_NUMBER":"794134","EVENT_NO":"4153079","INSPECTION_BEGIN_DT":"11/20/2003","INSPECTION_END_DT":"11/20/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2003-11-20"},{"SOURCE_ROW_NUMBER":"11596","EVENT_NO":"4152898","INSPECTION_BEGIN_DT":"09/03/2003","INSPECTION_END_DT":"09/03/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2003-09-03"},{"SOURCE_ROW_NUMBER":"1129852","EVENT_NO":"4152997","INSPECTION_BEGIN_DT":"06/18/2003","INSPECTION_END_DT":"06/18/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2003-06-18"},{"SOURCE_ROW_NUMBER":"948408","EVENT_NO":"4150997","INSPECTION_BEGIN_DT":"06/18/2003","INSPECTION_END_DT":"06/18/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2003-06-18"},{"SOURCE_ROW_NUMBER":"744008","EVENT_NO":"4144725","INSPECTION_BEGIN_DT":"06/02/2003","INSPECTION_END_DT":"06/02/2003","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2003-06-02"},{"SOURCE_ROW_NUMBER":"531786","EVENT_NO":"4150316","INSPECTION_BEGIN_DT":"05/06/2003","INSPECTION_END_DT":"05/13/2003","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2003-05-06"},{"SOURCE_ROW_NUMBER":"1126368","EVENT_NO":"4152869","INSPECTION_BEGIN_DT":"04/08/2003","INSPECTION_END_DT":"05/05/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"55","SUM_TOTAL_ON_SITE_HOURS":"31","sourceDate":"2003-04-08"},{"SOURCE_ROW_NUMBER":"760705","EVENT_NO":"4150304","INSPECTION_BEGIN_DT":"03/20/2003","INSPECTION_END_DT":"03/27/2003","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2003-03-20"},{"SOURCE_ROW_NUMBER":"783149","EVENT_NO":"4144388","INSPECTION_BEGIN_DT":"01/22/2003","INSPECTION_END_DT":"01/30/2003","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2003-01-22"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":38,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q3":{"hours":0,"employees":0,"production":0},"2004-Q2":{"hours":0,"employees":0,"production":0},"2004-Q1":{"hours":0,"employees":0,"production":0},"2003-Q4":{"hours":1648,"employees":3,"production":0},"2003-Q3":{"hours":2609,"employees":3,"production":0},"2003-Q2":{"hours":10188,"employees":13,"production":17433},"2003-Q1":{"hours":8312,"employees":14,"production":24268},"2002-Q4":{"hours":9444,"employees":12,"production":24178},"2002-Q3":{"hours":8543,"employees":12,"production":21032},"2002-Q2":{"hours":12094,"employees":15,"production":28520},"2002-Q1":{"hours":9545,"employees":15,"production":26046},"2001-Q4":{"hours":11216,"employees":15,"production":25767}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":27966,"employees":14,"production":60825},"2001":{"hours":46707,"employees":18,"production":117884},"2002":{"hours":39626,"employees":14,"production":99776},"2003":{"hours":22757,"employees":14,"production":41701}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":21,"firstDate":"2000-02-16","lastDate":"2002-12-17","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1407,"pelDoseTotal":1009},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"204554","EVENT_NO":"4150095","SURVEY_DATE":"12/17/2002","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2002-12-17"},{"SOURCE_ROW_NUMBER":"204553","EVENT_NO":"4150089","SURVEY_DATE":"10/02/2002","OCCUPATION_CD_DESC":"CUTTING MACHINE HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"72","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2002-10-02"},{"SOURCE_ROW_NUMBER":"204552","EVENT_NO":"4150089","SURVEY_DATE":"10/02/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"51","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2002-10-02"},{"SOURCE_ROW_NUMBER":"204551","EVENT_NO":"4150089","SURVEY_DATE":"10/02/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"74","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2002-10-02"},{"SOURCE_ROW_NUMBER":"204550","EVENT_NO":"4150089","SURVEY_DATE":"10/02/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"46","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2002-10-02"},{"SOURCE_ROW_NUMBER":"204549","EVENT_NO":"4150089","SURVEY_DATE":"10/02/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"64","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2002-10-02"},{"SOURCE_ROW_NUMBER":"204568","EVENT_NO":"4152653","SURVEY_DATE":"10/26/2001","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2001-10-26"},{"SOURCE_ROW_NUMBER":"204567","EVENT_NO":"4152648","SURVEY_DATE":"10/15/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"51","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2001-10-15"},{"SOURCE_ROW_NUMBER":"204566","EVENT_NO":"4152648","SURVEY_DATE":"10/15/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"48","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2001-10-15"},{"SOURCE_ROW_NUMBER":"204565","EVENT_NO":"4152648","SURVEY_DATE":"10/15/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"50","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2001-10-15"},{"SOURCE_ROW_NUMBER":"204564","EVENT_NO":"4152648","SURVEY_DATE":"10/15/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"68","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2001-10-15"},{"SOURCE_ROW_NUMBER":"204563","EVENT_NO":"4152648","SURVEY_DATE":"10/15/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"50","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2001-10-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":12,"firstDate":"2000-02-17","lastDate":"2002-10-02","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":6.7,"validSamples":10,"quartzPctTotal":42},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"85315","CASSETTE_NO":"57412151","SAMPLE_DT":"10/02/2002","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-10-02"},{"SOURCE_ROW_NUMBER":"123883","CASSETTE_NO":"50630290","SAMPLE_DT":"07/25/2002","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2002-07-25"},{"SOURCE_ROW_NUMBER":"107975","CASSETTE_NO":"50630299","SAMPLE_DT":"07/24/2002","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2002-07-24"},{"SOURCE_ROW_NUMBER":"112502","CASSETTE_NO":"57415828","SAMPLE_DT":"07/08/2002","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"21358","CASSETTE_NO":"57415744","SAMPLE_DT":"07/08/2002","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"12018","CASSETTE_NO":"57416030","SAMPLE_DT":"04/03/2002","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-04-03"},{"SOURCE_ROW_NUMBER":"141181","CASSETTE_NO":"57336155","SAMPLE_DT":"04/20/2001","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-20"},{"SOURCE_ROW_NUMBER":"75961","CASSETTE_NO":"57321901","SAMPLE_DT":"04/10/2001","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-10"},{"SOURCE_ROW_NUMBER":"32513","CASSETTE_NO":"57307591","SAMPLE_DT":"02/01/2001","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-01"},{"SOURCE_ROW_NUMBER":"40078","CASSETTE_NO":"57307004","SAMPLE_DT":"12/11/2000","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-12-11"},{"SOURCE_ROW_NUMBER":"92046","CASSETTE_NO":"57295409","SAMPLE_DT":"08/16/2000","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-08-16"},{"SOURCE_ROW_NUMBER":"165099","CASSETTE_NO":"57219718","SAMPLE_DT":"02/17/2000","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-02-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":65,"firstDate":"2000-02-03","lastDate":"2003-04-28","metrics":{"ss":26,"amountDue":4941,"contested":0,"amountPaid":4941,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":4941},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2389778","VIOLATION_NO":"7332034","VIOLATION_ISSUE_DT":"04/28/2003","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/28/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-04-28"},{"SOURCE_ROW_NUMBER":"2389777","VIOLATION_NO":"7332031","VIOLATION_ISSUE_DT":"04/16/2003","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/18/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-04-16"},{"SOURCE_ROW_NUMBER":"2389776","VIOLATION_NO":"7332030","VIOLATION_ISSUE_DT":"04/16/2003","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/16/2003","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2003-04-16"},{"SOURCE_ROW_NUMBER":"2389775","VIOLATION_NO":"7332029","VIOLATION_ISSUE_DT":"04/16/2003","SIG_SUB":"Y","PART_SECTION":"75.523-2(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/18/2003","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2003-04-16"},{"SOURCE_ROW_NUMBER":"2389774","VIOLATION_NO":"7332027","VIOLATION_ISSUE_DT":"04/08/2003","SIG_SUB":"N","PART_SECTION":"75.325(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/08/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-04-08"},{"SOURCE_ROW_NUMBER":"2389752","VIOLATION_NO":"7325414","VIOLATION_ISSUE_DT":"02/11/2003","SIG_SUB":"Y","PART_SECTION":"77.410(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2003","PROPOSED_PENALTY":"66","AMOUNT_DUE":"66","AMOUNT_PAID":"66","CONTESTED_IND":"N","sourceDate":"2003-02-11"},{"SOURCE_ROW_NUMBER":"2389751","VIOLATION_NO":"7325413","VIOLATION_ISSUE_DT":"02/04/2003","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-02-04"},{"SOURCE_ROW_NUMBER":"2389750","VIOLATION_NO":"7325412","VIOLATION_ISSUE_DT":"02/04/2003","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/04/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-02-04"},{"SOURCE_ROW_NUMBER":"2389749","VIOLATION_NO":"7325410","VIOLATION_ISSUE_DT":"01/31/2003","SIG_SUB":"N","PART_SECTION":"75.1107","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/10/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-01-31"},{"SOURCE_ROW_NUMBER":"2389808","VIOLATION_NO":"7325508","VIOLATION_ISSUE_DT":"12/31/2002","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/31/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-12-31"},{"SOURCE_ROW_NUMBER":"2389807","VIOLATION_NO":"7325507","VIOLATION_ISSUE_DT":"12/17/2002","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-12-17"},{"SOURCE_ROW_NUMBER":"2389806","VIOLATION_NO":"7325505","VIOLATION_ISSUE_DT":"12/17/2002","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"12/17/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-12-17"}]}],"safety":{"href":"/api/v1/mines/4406974/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406974/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment; performance requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-2","part":"75","subchapter":"O","subpart":"F","id":"75.523-2","citation":"30 CFR 75.523-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Air quantity.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.325","part":"75","subchapter":"O","subpart":"D","id":"75.325","citation":"30 CFR 75.325","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","heading":"Fire suppression devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107","part":"75","subchapter":"O","subpart":"L","id":"75.1107","citation":"30 CFR 75.1107","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406974","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}