{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4406929","name":"Deep Mine #26","status":"Abandoned and Sealed","status_date":"2018-11-29","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Dickenson","nearest_town":"Pound","operator_id":"0146274","operator_name":"Paramont Contura, LLC","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.0925,"longitude":-82.514722},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":15054},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406929","name":"Deep Mine #26"},"operator":{"type":"operator","id":"0146274","name":"Paramont Contura, LLC"},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00230","name":"Pittston Company"},"object":{"type":"mine","id":"4406929","name":"Deep Mine #26"},"validFrom":"1986-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|C00230|1986-06-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17909","name":"Paramont Coal Corporation"},"object":{"type":"mine","id":"4406929","name":"Deep Mine #26"},"validFrom":"1998-09-01","validTo":"2002-12-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|P17909|1998-09-01|2002-12-12"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00230","name":"Pittston Company"},"object":{"type":"operator","id":"P17909","name":"Paramont Coal Corporation"},"validFrom":"1998-09-01","validTo":"2002-12-12","current":false,"derived":true,"evidenceMineId":"4406929","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|P17909|1998-09-01|C00230|1986-06-01|45335"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"object":{"type":"mine","id":"4406929","name":"Deep Mine #26"},"validFrom":"2002-12-13","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|0050885|2002-12-13|2016-07-25"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4406929","name":"Deep Mine #26"},"validFrom":"2002-12-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|0041211|2002-12-13|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"validFrom":"2002-12-13","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"4406929","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|0050885|2002-12-13|0041211|2002-12-13|1591"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0146274","name":"Paramont Contura, LLC"},"object":{"type":"mine","id":"4406929","name":"Deep Mine #26"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|0146274|2016-07-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"4406929","name":"Deep Mine #26"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|0127321|2016-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"0146274","name":"Paramont Contura, LLC"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406929","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406929|0146274|2016-07-26|0127321|2016-07-26|24718"}}],"coverage":{"historyRecords":3,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":261,"firstDate":"2000-12-06","lastDate":"2018-05-21","metrics":{"daysLost":8374,"injuries":220,"fatalities":0,"recentRows":0,"restrictedDays":164,"contractorRecords":13},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"244232","DOCUMENT_NO":"220181520014","ACCIDENT_DT":"05/21/2018","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Grader operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a CWP diagnosis for employee on 5/21/2018. Employee last worked on 11/3/2017 and has been termed.","sourceDate":"2018-05-21"},{"SOURCE_ROW_NUMBER":"218403","DOCUMENT_NO":"220181520015","ACCIDENT_DT":"05/21/2018","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a CWP diagnosis for employee on 5/21/2018. Employee was termed on 3/28/2017.","sourceDate":"2018-05-21"},{"SOURCE_ROW_NUMBER":"89308","DOCUMENT_NO":"220171860024","ACCIDENT_DT":"06/29/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"99","NARRATIVE":"Employee was bolting the 2nd cut out of 4R. While installing a rib bolt in 3rd row of bolts a piece of draw rock measuring 70.5\" long, 0\" to 6.5\" thick and 46.5\" wide fell out from the top and the edge of the rock caught the back of EE's right heel causing an avulsion. **Also fracture to heal bone.**","sourceDate":"2017-06-29"},{"SOURCE_ROW_NUMBER":"67740","DOCUMENT_NO":"220171730013","ACCIDENT_DT":"06/14/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"83","NARRATIVE":"Employee was pulling a miner cable pull rope to attach it to the tail boom of the miner and fell after becoming entangled in the miner water line. Employee fell backwards on to left buttocks. Employee is complaining of pain near tail bone radiating down left leg. Employee continued to work until 6/21/17.","sourceDate":"2017-06-14"},{"SOURCE_ROW_NUMBER":"184003","DOCUMENT_NO":"220170790005","ACCIDENT_DT":"03/09/2017","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was loading high voltage cable. The employee tripped over the cable causing them to fall landing on the left arm resulting in a fracture of the left radius.","sourceDate":"2017-03-09"},{"SOURCE_ROW_NUMBER":"59142","DOCUMENT_NO":"220163280004","ACCIDENT_DT":"11/14/2016","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Superior Coal Services Contractor was attempting to go through a mandoor. EE states, pushed the door open to step through. Stuck hand out to catch the spring loaded door and when it came back the locking mechanism of the door had a sharp corner that hit right pinky finger causing a laceration requiring stitches.","sourceDate":"2016-11-14"},{"SOURCE_ROW_NUMBER":"123506","DOCUMENT_NO":"220162780001","ACCIDENT_DT":"09/26/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"23","NARRATIVE":"Employee suffered an injury to EE's right shoulder on 10/15/15 with a previous employer which required surgery. EE was released from the Dr. on 9/12/16 and was hired at this mine on 9/20/16. On 9/23/16 EE started having pain in the same shoulder and sought a medical evaluation and was diagnosed with Tendonitis and/or Tenosynovitis on 9/26/16 from EE's previous injury.","sourceDate":"2016-09-26"},{"SOURCE_ROW_NUMBER":"106251","DOCUMENT_NO":"220162000043","ACCIDENT_DT":"07/12/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Trackman, Track worker, Track gang","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a hearing loss diagnosis for employee. EE last worked on 7/2/14.","sourceDate":"2016-07-12"},{"SOURCE_ROW_NUMBER":"46354","DOCUMENT_NO":"220161120015","ACCIDENT_DT":"04/20/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a hearing loss diagnosis for EE. EE voluntarily quit and was termed on 3/31/15.","sourceDate":"2016-04-20"},{"SOURCE_ROW_NUMBER":"20531","DOCUMENT_NO":"220160850011","ACCIDENT_DT":"03/22/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a CWP diagnosis for EE. EE was termed on 12/26/2014.","sourceDate":"2016-03-22"},{"SOURCE_ROW_NUMBER":"192525","DOCUMENT_NO":"220160850022","ACCIDENT_DT":"03/21/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a CWP diagnosis for employee.","sourceDate":"2016-03-21"},{"SOURCE_ROW_NUMBER":"248564","DOCUMENT_NO":"220160850024","ACCIDENT_DT":"03/16/2016","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Safety director","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Received a CWP diagnosis for employee.","sourceDate":"2016-03-16"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2018-11-29","lastDate":"2018-11-29","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":2276,"firstDate":"2000-12-13","lastDate":"2018-06-11","metrics":{"ss":717,"delinquent":2193,"recentRows":0,"paidPenalty":1145350.39,"proposedPenalty":1444730,"currentAssessment":1149353.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1403741","VIOLATION_NO":"9874132","ISSUE_DT":"06/11/2018","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1666.00","CURRENT_ASSESSMENT_AMT":"1666.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"1403740","VIOLATION_NO":"9874131","ISSUE_DT":"06/11/2018","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"1403739","VIOLATION_NO":"9874130","ISSUE_DT":"06/11/2018","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"1403738","VIOLATION_NO":"9874129","ISSUE_DT":"06/11/2018","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"1392218","VIOLATION_NO":"8272475","ISSUE_DT":"09/08/2017","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"533.00","CURRENT_ASSESSMENT_AMT":"533.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-09-08"},{"SOURCE_ROW_NUMBER":"1392217","VIOLATION_NO":"8272474","ISSUE_DT":"08/15/2017","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"173.00","CURRENT_ASSESSMENT_AMT":"173.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"1386377","VIOLATION_NO":"8194491","ISSUE_DT":"08/04/2017","CFR_STANDARD_CD":"75.204(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-08-04"},{"SOURCE_ROW_NUMBER":"1392227","VIOLATION_NO":"8272470","ISSUE_DT":"07/31/2017","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"677.00","CURRENT_ASSESSMENT_AMT":"677.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-07-31"},{"SOURCE_ROW_NUMBER":"1392216","VIOLATION_NO":"7387750","ISSUE_DT":"07/18/2017","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"188.00","CURRENT_ASSESSMENT_AMT":"188.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-07-18"},{"SOURCE_ROW_NUMBER":"1389697","VIOLATION_NO":"8301163","ISSUE_DT":"07/17/2017","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-07-17"},{"SOURCE_ROW_NUMBER":"1392215","VIOLATION_NO":"8272460","ISSUE_DT":"06/20/2017","CFR_STANDARD_CD":"75.1107-3(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-06-20"},{"SOURCE_ROW_NUMBER":"1392214","VIOLATION_NO":"8272457","ISSUE_DT":"05/16/2017","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"148.00","CURRENT_ASSESSMENT_AMT":"148.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-05-16"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":695,"firstDate":"2001-05-16","lastDate":"2018-05-03","metrics":{"appeals":0,"decisions":695,"recentRows":0,"decisionPenalty":675443.5,"originalPenalty":985245},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"127069","VIOLATION_NO":"7346007","DOCKET_NO":"VA 2017-0134","DECISION_DT":"05/03/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"356.00","DECISION_PENALTY_AMT":"256.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-05-03"},{"SOURCE_ROW_NUMBER":"126430","VIOLATION_NO":"7346008","DOCKET_NO":"VA 2017-0134","DECISION_DT":"05/03/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1770.00","DECISION_PENALTY_AMT":"1138.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-05-03"},{"SOURCE_ROW_NUMBER":"128354","VIOLATION_NO":"8177247","DOCKET_NO":"VA 2017-0193","DECISION_DT":"02/15/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"173.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-02-15"},{"SOURCE_ROW_NUMBER":"387951","VIOLATION_NO":"8191490","DOCKET_NO":"VA 2017-0038","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"446.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"387950","VIOLATION_NO":"8191480","DOCKET_NO":"VA 2017-0038","DECISION_DT":"12/20/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1168.00","DECISION_PENALTY_AMT":"800.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Steele","sourceDate":"2017-12-20"},{"SOURCE_ROW_NUMBER":"387147","VIOLATION_NO":"8191465","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"722.00","DECISION_PENALTY_AMT":"361.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-27"},{"SOURCE_ROW_NUMBER":"386884","VIOLATION_NO":"8272372","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1078.00","DECISION_PENALTY_AMT":"539.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-27"},{"SOURCE_ROW_NUMBER":"386883","VIOLATION_NO":"8193658","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1265.00","DECISION_PENALTY_AMT":"632.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-27"},{"SOURCE_ROW_NUMBER":"386785","VIOLATION_NO":"8191463","DOCKET_NO":"VA 2017-0004","DECISION_DT":"07/27/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"583.00","DECISION_PENALTY_AMT":"291.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-27"},{"SOURCE_ROW_NUMBER":"386784","VIOLATION_NO":"8193668","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"235.00","DECISION_PENALTY_AMT":"117.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-27"},{"SOURCE_ROW_NUMBER":"386783","VIOLATION_NO":"8191457","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"185.00","DECISION_PENALTY_AMT":"92.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-27"},{"SOURCE_ROW_NUMBER":"386335","VIOLATION_NO":"8191459","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"134.00","DECISION_PENALTY_AMT":"67.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-27"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":4706,"firstDate":"2001-03-29","lastDate":"2018-11-14","metrics":{"recentRows":0,"cpdmSamples":316,"voidSamples":241,"validSamples":4465,"maxConcentration":7.86,"concentrationTotal":2663.01},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"541108","CASS_NUM":"58319920","SMP_TAKEN_DT":"11/14/2018","CONC":".001","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-11-14"},{"SOURCE_ROW_NUMBER":"213433","CASS_NUM":"58319923","SMP_TAKEN_DT":"11/14/2018","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-11-14"},{"SOURCE_ROW_NUMBER":"633000","CASS_NUM":"51519270","SMP_TAKEN_DT":"10/4/2018","CONC":".066","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-10-04"},{"SOURCE_ROW_NUMBER":"1411262","CASS_NUM":"58332676","SMP_TAKEN_DT":"9/13/2018","CONC":".031","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-09-13"},{"SOURCE_ROW_NUMBER":"1191177","CASS_NUM":"58332943","SMP_TAKEN_DT":"9/13/2018","CONC":".038","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-09-13"},{"SOURCE_ROW_NUMBER":"206261","CASS_NUM":"58332972","SMP_TAKEN_DT":"9/13/2018","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"OUTSIDE FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-09-13"},{"SOURCE_ROW_NUMBER":"570322","CASS_NUM":"51518225","SMP_TAKEN_DT":"7/3/2018","CONC":".033","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-07-03"},{"SOURCE_ROW_NUMBER":"845762","CASS_NUM":"51511304","SMP_TAKEN_DT":"6/28/2018","CONC":".026","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"471804","CASS_NUM":"58334436","SMP_TAKEN_DT":"6/28/2018","CONC":".029","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"392765","CASS_NUM":"58334435","SMP_TAKEN_DT":"6/28/2018","CONC":".059","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"264049","CASS_NUM":"58334414","SMP_TAKEN_DT":"6/28/2018","CONC":".035","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"70399","CASS_NUM":"51463443","SMP_TAKEN_DT":"8/10/2017","CONC":".182","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-08-10"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":142,"firstDate":"2000-12-28","lastDate":"2017-06-22","metrics":{"linkedIssuances":142},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":694,"firstDate":"2004-10-14","lastDate":"2017-04-24","metrics":{"decisions":694,"ssChanged":123,"recentRows":0,"decisionPenalty":675293.5,"proposedPenalty":985038},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"326559","CITATION_NO":"8177247","CITATION_ISSUE_DT":"04/24/2017","DOCKET_NO":"VA 2017-0193","DECISION_DT":"02/15/2018","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"173.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2017-04-24"},{"SOURCE_ROW_NUMBER":"268139","CITATION_NO":"7346007","CITATION_ISSUE_DT":"01/25/2017","DOCKET_NO":"VA 2017-0134","DECISION_DT":"05/03/2018","CFR_STANDARD_CODE":"75.1714-4(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"356.00","DECISION_PENALTY_AMT":"256.00","sourceDate":"2017-01-25"},{"SOURCE_ROW_NUMBER":"43267","CITATION_NO":"7346008","CITATION_ISSUE_DT":"01/25/2017","DOCKET_NO":"VA 2017-0134","DECISION_DT":"05/03/2018","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1770.00","DECISION_PENALTY_AMT":"1138.00","sourceDate":"2017-01-25"},{"SOURCE_ROW_NUMBER":"265348","CITATION_NO":"8191490","CITATION_ISSUE_DT":"08/25/2016","DOCKET_NO":"VA 2017-0038","DECISION_DT":"12/20/2017","CFR_STANDARD_CODE":"77.904","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"446.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2016-08-25"},{"SOURCE_ROW_NUMBER":"439488","CITATION_NO":"8191480","CITATION_ISSUE_DT":"08/23/2016","DOCKET_NO":"VA 2017-0038","DECISION_DT":"12/20/2017","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1168.00","DECISION_PENALTY_AMT":"800.00","sourceDate":"2016-08-23"},{"SOURCE_ROW_NUMBER":"155913","CITATION_NO":"8181476","CITATION_ISSUE_DT":"07/29/2016","DOCKET_NO":"VA 2017-0022","DECISION_DT":"06/27/2017","CFR_STANDARD_CODE":"75.204(c)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"666.00","DECISION_PENALTY_AMT":"465.00","sourceDate":"2016-07-29"},{"SOURCE_ROW_NUMBER":"322033","CITATION_NO":"8191465","CITATION_ISSUE_DT":"07/25/2016","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","CFR_STANDARD_CODE":"75.1107-13(f)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"722.00","DECISION_PENALTY_AMT":"361.00","sourceDate":"2016-07-25"},{"SOURCE_ROW_NUMBER":"266098","CITATION_NO":"8191463","CITATION_ISSUE_DT":"07/25/2016","DOCKET_NO":"VA 2017-0004","DECISION_DT":"07/27/2017","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"583.00","DECISION_PENALTY_AMT":"291.50","sourceDate":"2016-07-25"},{"SOURCE_ROW_NUMBER":"95566","CITATION_NO":"8191464","CITATION_ISSUE_DT":"07/25/2016","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","CFR_STANDARD_CODE":"75.1715","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"134.00","DECISION_PENALTY_AMT":"67.00","sourceDate":"2016-07-25"},{"SOURCE_ROW_NUMBER":"381094","CITATION_NO":"8191460","CITATION_ISSUE_DT":"07/07/2016","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","CFR_STANDARD_CODE":"75.1505(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"524.00","DECISION_PENALTY_AMT":"262.00","sourceDate":"2016-07-07"},{"SOURCE_ROW_NUMBER":"377959","CITATION_NO":"8191457","CITATION_ISSUE_DT":"07/07/2016","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"185.00","DECISION_PENALTY_AMT":"92.50","sourceDate":"2016-07-07"},{"SOURCE_ROW_NUMBER":"96013","CITATION_NO":"8191459","CITATION_ISSUE_DT":"07/07/2016","DOCKET_NO":"VA 2017-0003","DECISION_DT":"07/27/2017","CFR_STANDARD_CODE":"75.1719-4(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"134.00","DECISION_PENALTY_AMT":"67.00","sourceDate":"2016-07-07"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1297,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":11,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":288,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":10,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1998-09-01","lastDate":"2016-07-26","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":1409,"firstDate":"2000-10-30","lastDate":"2018-11-29","metrics":{"inspectors":1968,"recentRows":0,"onSiteHours":25116.75,"inspectionHours":37275.75,"inspectionSamples":4476},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"261763","EVENT_NO":"4422452","INSPECTION_BEGIN_DT":"11/29/2018","INSPECTION_END_DT":"11/29/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2018-11-29"},{"SOURCE_ROW_NUMBER":"270177","EVENT_NO":"4421623","INSPECTION_BEGIN_DT":"11/13/2018","INSPECTION_END_DT":"11/21/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"26","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2018-11-13"},{"SOURCE_ROW_NUMBER":"516082","EVENT_NO":"4422418","INSPECTION_BEGIN_DT":"07/18/2018","INSPECTION_END_DT":"09/14/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"24.5","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2018-07-18"},{"SOURCE_ROW_NUMBER":"390466","EVENT_NO":"4422270","INSPECTION_BEGIN_DT":"06/28/2018","INSPECTION_END_DT":"06/28/2018","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"21447","EVENT_NO":"4418455","INSPECTION_BEGIN_DT":"06/27/2018","INSPECTION_END_DT":"07/05/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2018-06-27"},{"SOURCE_ROW_NUMBER":"992476","EVENT_NO":"4421608","INSPECTION_BEGIN_DT":"06/21/2018","INSPECTION_END_DT":"06/21/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2018-06-21"},{"SOURCE_ROW_NUMBER":"920839","EVENT_NO":"4422413","INSPECTION_BEGIN_DT":"05/22/2018","INSPECTION_END_DT":"06/12/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"25.75","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2018-05-22"},{"SOURCE_ROW_NUMBER":"758315","EVENT_NO":"4421601","INSPECTION_BEGIN_DT":"02/09/2018","INSPECTION_END_DT":"03/13/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2018-02-09"},{"SOURCE_ROW_NUMBER":"184312","EVENT_NO":"4421057","INSPECTION_BEGIN_DT":"01/16/2018","INSPECTION_END_DT":"01/19/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2018-01-16"},{"SOURCE_ROW_NUMBER":"612764","EVENT_NO":"4422121","INSPECTION_BEGIN_DT":"12/18/2017","INSPECTION_END_DT":"12/18/2017","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2017-12-18"},{"SOURCE_ROW_NUMBER":"854242","EVENT_NO":"4418317","INSPECTION_BEGIN_DT":"11/28/2017","INSPECTION_END_DT":"11/28/2017","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2017-11-28"},{"SOURCE_ROW_NUMBER":"801974","EVENT_NO":"4418517","INSPECTION_BEGIN_DT":"11/22/2017","INSPECTION_END_DT":"11/22/2017","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2017-11-22"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":192,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2018-Q4":{"hours":0,"employees":0,"production":0},"2018-Q3":{"hours":0,"employees":0,"production":0},"2018-Q2":{"hours":0,"employees":0,"production":0},"2018-Q1":{"hours":0,"employees":0,"production":0},"2017-Q4":{"hours":2117,"employees":10,"production":57},"2017-Q3":{"hours":30730,"employees":67,"production":62071},"2017-Q2":{"hours":44474,"employees":89,"production":123654},"2017-Q1":{"hours":45832,"employees":88,"production":101734},"2016-Q4":{"hours":41315,"employees":86,"production":74637},"2016-Q3":{"hours":47061,"employees":87,"production":89608},"2016-Q2":{"hours":45791,"employees":88,"production":86033},"2016-Q1":{"hours":47714,"employees":87,"production":96379}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":37,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":575872,"employees":257,"production":1587512},"2009":{"hours":580999,"employees":247,"production":1541364},"2010":{"hours":640667,"employees":274,"production":1642479},"2011":{"hours":607000,"employees":258,"production":1264570},"2012":{"hours":497185,"employees":207,"production":977594},"2013":{"hours":487865,"employees":206,"production":818477},"2014":{"hours":436030,"employees":185,"production":713642},"2015":{"hours":279347,"employees":120,"production":436476},"2016":{"hours":181881,"employees":87,"production":346657},"2017":{"hours":123153,"employees":64,"production":287516}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":438,"firstDate":"2001-08-16","lastDate":"2018-11-14","metrics":{"recentRows":0,"doseOver100":128,"actDoseTotal":39307,"pelDoseTotal":29396},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"203919","EVENT_NO":"4421623","SURVEY_DATE":"11/14/2018","OCCUPATION_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"14","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2018-11-14"},{"SOURCE_ROW_NUMBER":"203918","EVENT_NO":"4421623","SURVEY_DATE":"11/14/2018","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"68","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2018-11-14"},{"SOURCE_ROW_NUMBER":"203910","EVENT_NO":"4418455","SURVEY_DATE":"06/28/2018","OCCUPATION_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","MACHINE_CD":"31","MANUFACTURER_CD":"018","ACT_DOSE_85":"10","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"203909","EVENT_NO":"4418455","SURVEY_DATE":"06/28/2018","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"119","ACT_DOSE_85":"92","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"203908","EVENT_NO":"4418455","SURVEY_DATE":"06/28/2018","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"11","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2018-06-28"},{"SOURCE_ROW_NUMBER":"203917","EVENT_NO":"4418600","SURVEY_DATE":"03/14/2017","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"75","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2017-03-14"},{"SOURCE_ROW_NUMBER":"203916","EVENT_NO":"4418600","SURVEY_DATE":"03/14/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"110","PEL_DOSE_90":"102","SURVEY_TYPE":"I","sourceDate":"2017-03-14"},{"SOURCE_ROW_NUMBER":"203915","EVENT_NO":"4418600","SURVEY_DATE":"03/14/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"101","PEL_DOSE_90":"87","SURVEY_TYPE":"I","sourceDate":"2017-03-14"},{"SOURCE_ROW_NUMBER":"203914","EVENT_NO":"4418600","SURVEY_DATE":"03/14/2017","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"83","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2017-03-14"},{"SOURCE_ROW_NUMBER":"203913","EVENT_NO":"4418600","SURVEY_DATE":"03/14/2017","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"38","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2017-03-14"},{"SOURCE_ROW_NUMBER":"203912","EVENT_NO":"4418490","SURVEY_DATE":"11/15/2016","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"5","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2016-11-15"},{"SOURCE_ROW_NUMBER":"203911","EVENT_NO":"4418490","SURVEY_DATE":"11/15/2016","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"24","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2016-11-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":291,"firstDate":"2002-09-03","lastDate":"2017-07-18","metrics":{"recentRows":0,"voidSamples":13,"maxQuartzPct":58.1,"validSamples":278,"quartzPctTotal":1096.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"165739","CASSETTE_NO":"58295115","SAMPLE_DT":"07/18/2017","QUARTZ_PCT":"03.5","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-07-18"},{"SOURCE_ROW_NUMBER":"149820","CASSETTE_NO":"58295137","SAMPLE_DT":"07/18/2017","QUARTZ_PCT":"04.6","QUARTZ_MICROGRAMS":"19","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-07-18"},{"SOURCE_ROW_NUMBER":"116750","CASSETTE_NO":"58295188","SAMPLE_DT":"07/18/2017","QUARTZ_PCT":"01.5","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-07-18"},{"SOURCE_ROW_NUMBER":"103260","CASSETTE_NO":"58295132","SAMPLE_DT":"07/18/2017","QUARTZ_PCT":"05.6","QUARTZ_MICROGRAMS":"24","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-07-18"},{"SOURCE_ROW_NUMBER":"136342","CASSETTE_NO":"58274690","SAMPLE_DT":"05/02/2017","QUARTZ_PCT":"06.7","QUARTZ_MICROGRAMS":"30","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-05-02"},{"SOURCE_ROW_NUMBER":"126208","CASSETTE_NO":"58274681","SAMPLE_DT":"05/02/2017","QUARTZ_PCT":"06.2","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-05-02"},{"SOURCE_ROW_NUMBER":"103733","CASSETTE_NO":"58275053","SAMPLE_DT":"05/02/2017","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-05-02"},{"SOURCE_ROW_NUMBER":"58664","CASSETTE_NO":"58274721","SAMPLE_DT":"05/02/2017","QUARTZ_PCT":"04.0","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-05-02"},{"SOURCE_ROW_NUMBER":"92285","CASSETTE_NO":"58274650","SAMPLE_DT":"01/10/2017","QUARTZ_PCT":"03.6","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-01-10"},{"SOURCE_ROW_NUMBER":"75963","CASSETTE_NO":"58274512","SAMPLE_DT":"01/10/2017","QUARTZ_PCT":"05.4","QUARTZ_MICROGRAMS":"32","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2017-01-10"},{"SOURCE_ROW_NUMBER":"12272","CASSETTE_NO":"58274510","SAMPLE_DT":"01/10/2017","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2017-01-10"},{"SOURCE_ROW_NUMBER":"134518","CASSETTE_NO":"58262298","SAMPLE_DT":"10/19/2016","QUARTZ_PCT":"02.8","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2016-10-19"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":2323,"firstDate":"2000-12-13","lastDate":"2018-06-11","metrics":{"ss":719,"amountDue":1149353.5,"contested":163,"amountPaid":1145350.39,"recentRows":0,"section104d":0,"unterminated":2,"proposedPenalty":1444730},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2383739","VIOLATION_NO":"9874132","VIOLATION_ISSUE_DT":"06/11/2018","SIG_SUB":"Y","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/11/2018","PROPOSED_PENALTY":"1666","AMOUNT_DUE":"1666","AMOUNT_PAID":"1666","CONTESTED_IND":"N","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"2383738","VIOLATION_NO":"9874131","VIOLATION_ISSUE_DT":"06/11/2018","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/11/2018","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"2383737","VIOLATION_NO":"9874130","VIOLATION_ISSUE_DT":"06/11/2018","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/11/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"2383736","VIOLATION_NO":"9874129","VIOLATION_ISSUE_DT":"06/11/2018","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/12/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-06-11"},{"SOURCE_ROW_NUMBER":"2384204","VIOLATION_NO":"8272475","VIOLATION_ISSUE_DT":"09/08/2017","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2017","PROPOSED_PENALTY":"533","AMOUNT_DUE":"533","AMOUNT_PAID":"533","CONTESTED_IND":"N","sourceDate":"2017-09-08"},{"SOURCE_ROW_NUMBER":"2384203","VIOLATION_NO":"8272474","VIOLATION_ISSUE_DT":"08/15/2017","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/15/2017","PROPOSED_PENALTY":"173","AMOUNT_DUE":"173","AMOUNT_PAID":"173","CONTESTED_IND":"N","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"2384304","VIOLATION_NO":"8194491","VIOLATION_ISSUE_DT":"08/04/2017","SIG_SUB":"N","PART_SECTION":"75.204(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/04/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"116","CONTESTED_IND":"N","sourceDate":"2017-08-04"},{"SOURCE_ROW_NUMBER":"2384299","VIOLATION_NO":"8272470","VIOLATION_ISSUE_DT":"07/31/2017","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/31/2017","PROPOSED_PENALTY":"677","AMOUNT_DUE":"677","AMOUNT_PAID":"677","CONTESTED_IND":"N","sourceDate":"2017-07-31"},{"SOURCE_ROW_NUMBER":"2384202","VIOLATION_NO":"7387750","VIOLATION_ISSUE_DT":"07/18/2017","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2017","PROPOSED_PENALTY":"188","AMOUNT_DUE":"188","AMOUNT_PAID":"188","CONTESTED_IND":"N","sourceDate":"2017-07-18"},{"SOURCE_ROW_NUMBER":"2384282","VIOLATION_NO":"8301163","VIOLATION_ISSUE_DT":"07/17/2017","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/17/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"116","CONTESTED_IND":"N","sourceDate":"2017-07-17"},{"SOURCE_ROW_NUMBER":"2383783","VIOLATION_NO":"8272460","VIOLATION_ISSUE_DT":"06/20/2017","SIG_SUB":"N","PART_SECTION":"75.1107-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/20/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"116","CONTESTED_IND":"N","sourceDate":"2017-06-20"},{"SOURCE_ROW_NUMBER":"2383730","VIOLATION_NO":"8272457","VIOLATION_ISSUE_DT":"05/16/2017","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2017","PROPOSED_PENALTY":"148","AMOUNT_DUE":"148","AMOUNT_PAID":"148","CONTESTED_IND":"N","sourceDate":"2017-05-16"}]}],"safety":{"href":"/api/v1/mines/4406929/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406929/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3},{"chapter":"I","heading":"Roof bolting.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.204","part":"75","subchapter":"O","subpart":"C","id":"75.204","citation":"30 CFR 75.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Fire suppression devices; approved components; installation requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-3","part":"75","subchapter":"O","subpart":"L","id":"75.1107-3","citation":"30 CFR 75.1107-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406929","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}