{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4406896","name":"#5","status":"Abandoned and Sealed","status_date":"2006-01-10","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Buchanan","nearest_town":"Hurley","operator_id":"P23324","operator_name":"Laurel Creek Mining Corp","controller_id":"C03173","controller_name":"James R  Gibbs","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.456944,"longitude":-82.076388},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":809},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406896","name":"#5"},"operator":{"type":"operator","id":"P23324","name":"Laurel Creek Mining Corp"},"controller":{"type":"controller","id":"C03173","name":"James R  Gibbs"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C09013","name":"Jerry  Skeens  et al"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1987-06-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|C09013|1987-06-19|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00286","name":"TECO Energy Inc"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1988-04-26","validTo":"2015-09-20","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|C00286|1988-04-26|2015-09-20"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03173","name":"James R  Gibbs et al"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1995-09-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|C03173|1995-09-05|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1996-10-24","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|C15455|1996-10-24|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23562","name":"Race Fork Coal Corp"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1997-11-01","validTo":"1998-04-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P23562|1997-11-01|1998-04-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"P23562","name":"Race Fork Coal Corp"},"validFrom":"1997-11-01","validTo":"1998-04-14","current":false,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P23562|1997-11-01|C15455|1996-10-24|95644"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19062","name":"Falcon Coal Corp"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1998-04-15","validTo":"1999-04-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P19062|1998-04-15|1999-04-22"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09013","name":"Jerry  Skeens  et al"},"object":{"type":"operator","id":"P19062","name":"Falcon Coal Corp"},"validFrom":"1998-04-15","validTo":"1999-04-22","current":false,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P19062|1998-04-15|C09013|1987-06-19|78701"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09013","name":"Eddie  Skeens  et al"},"object":{"type":"operator","id":"P19062","name":"Falcon Coal Corp"},"validFrom":"1998-04-15","validTo":"1999-04-22","current":false,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P19062|1998-04-15|C09013|1987-06-19|78702"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23562","name":"Race Fork Coal Corp"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1999-04-23","validTo":"1999-07-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P23562|1999-04-23|1999-07-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"P23562","name":"Race Fork Coal Corp"},"validFrom":"1999-04-23","validTo":"1999-07-14","current":false,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P23562|1999-04-23|C15455|1996-10-24|95645"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19736","name":"Clintwood Elkhorn Mining Company Inc"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1999-07-15","validTo":"1999-08-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P19736|1999-07-15|1999-08-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00286","name":"TECO Energy Inc"},"object":{"type":"operator","id":"P19736","name":"Clintwood Elkhorn Mining Company Inc"},"validFrom":"1999-07-15","validTo":"1999-08-16","current":false,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P19736|1999-07-15|C00286|1988-04-26|45802"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23324","name":"Laurel Creek Mining Corp"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"1999-08-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P23324|1999-08-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03173","name":"James R  Gibbs et al"},"object":{"type":"operator","id":"P23324","name":"Laurel Creek Mining Corp"},"validFrom":"1999-08-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P23324|1999-08-17|C03173|1995-09-05|62141"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"2015-09-21","validTo":"2019-06-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|C11194|2015-09-21|2019-06-15"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"operator","id":"P19736","name":"Clintwood Elkhorn Mining Company Inc"},"validFrom":"2015-09-21","validTo":"1999-08-16","current":false,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P19736|1999-07-15|C11194|2015-09-21|84076"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0149203","name":"J Mark  Campbell"},"object":{"type":"mine","id":"4406896","name":"#5"},"validFrom":"2019-06-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|0149203|2019-06-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0149203","name":"J Mark  Campbell"},"object":{"type":"operator","id":"P19736","name":"Clintwood Elkhorn Mining Company Inc"},"validFrom":"2019-06-16","validTo":"1999-08-16","current":false,"derived":true,"evidenceMineId":"4406896","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406896|P19736|1999-07-15|0149203|2019-06-16|30642"}}],"coverage":{"historyRecords":8,"edgeCount":19,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":6,"firstDate":"2000-02-23","lastDate":"2003-06-04","metrics":{"daysLost":51,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"196705","DOCUMENT_NO":"220031630004","ACCIDENT_DT":"06/04/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"FALL DISCOVERED IN BLEEDER ENTRIES INBY SPAD # 469 AJACENT TO PILLAR OUT AREA OF 3RD LEFT PANEL ON A REGULAR INSPECTION BY MSHA REP. AND MINE FOREMAN.","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"235656","DOCUMENT_NO":"220023080010","ACCIDENT_DT":"10/21/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"THIRD INTERSECTION INBY SPAD STATION 491 A ROOF FALL OCCURRED. MEASURING 20' IN WIDTH, APP 5' IN HEIGHT AND 70' IN LENGTH. FELL ABOVE ANCHORAGE POINT. FALL DOES NOT IMPAIR TRAVELWAY OR VENTILA TION.","sourceDate":"2002-10-21"},{"SOURCE_ROW_NUMBER":"59132","DOCUMENT_NO":"220021830067","ACCIDENT_DT":"06/17/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"9","NARRATIVE":"WHEN CENTER SECTION FROM 820 UN-HAULER WAS REMOVED FROM HAULER, BED SHIFTED SQUEEZING VICTIM BETWEEN BED & ROOF DUE TO ABSENCE OF WEIGHT OF CENTER SECTION. VICTIM WAS ASKED IF HE WAS IN THE CL EAR BEFORE CENTER SECTION WAS REMOVED AND VICTIM STATED HE WAS.","sourceDate":"2002-06-17"},{"SOURCE_ROW_NUMBER":"110635","DOCUMENT_NO":"220010330060","ACCIDENT_DT":"01/16/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"PIECE OF DRAW SLATE FELL, STRIKING BOTTOM OF FOOT.","sourceDate":"2001-01-16"},{"SOURCE_ROW_NUMBER":"171129","DOCUMENT_NO":"220002350020","ACCIDENT_DT":"08/08/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"42","NARRATIVE":"VICTIM ALLEDGED BACK STRAIN WHILE SHOVELING MATERIAL ON BELT CONVEYOR WITH A #2 ALUMINUM SHOVEL.","sourceDate":"2000-08-08"},{"SOURCE_ROW_NUMBER":"231298","DOCUMENT_NO":"220000660030","ACCIDENT_DT":"02/23/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"RIGHT BRAKE OFF #6 HEADING A FALL OCCURRED MEASURE 30' IN LENGTH AND 20' IN WIDTH FELL ABOVE ANCHORAGE POINT 48\" RESIN BOLTS. FALL OCCURRED ON SHIFT AND WAS NOT CLEANED-UP. TIMBERED AND DANGER ED OFF PRIOR TO FALL OCCURING.","sourceDate":"2000-02-23"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-01-10","lastDate":"2006-01-10","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":93,"firstDate":"2000-01-12","lastDate":"2005-12-01","metrics":{"ss":26,"delinquent":93,"recentRows":0,"paidPenalty":6332,"proposedPenalty":6332,"currentAssessment":6332},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"918001","VIOLATION_NO":"7311010","ISSUE_DT":"12/01/2005","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"911157","VIOLATION_NO":"7340174","ISSUE_DT":"09/14/2004","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-09-14"},{"SOURCE_ROW_NUMBER":"910774","VIOLATION_NO":"7339725","ISSUE_DT":"05/04/2004","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"911090","VIOLATION_NO":"7339785","ISSUE_DT":"04/23/2004","CFR_STANDARD_CD":"62.130(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"135.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-23"},{"SOURCE_ROW_NUMBER":"910763","VIOLATION_NO":"7332700","ISSUE_DT":"04/20/2004","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-20"},{"SOURCE_ROW_NUMBER":"910762","VIOLATION_NO":"7332693","ISSUE_DT":"04/02/2004","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"99.00","CURRENT_ASSESSMENT_AMT":"99.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-02"},{"SOURCE_ROW_NUMBER":"910761","VIOLATION_NO":"7332692","ISSUE_DT":"04/02/2004","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"99.00","CURRENT_ASSESSMENT_AMT":"99.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-02"},{"SOURCE_ROW_NUMBER":"910485","VIOLATION_NO":"7332448","ISSUE_DT":"01/14/2004","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-14"},{"SOURCE_ROW_NUMBER":"910484","VIOLATION_NO":"7332447","ISSUE_DT":"01/12/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-12"},{"SOURCE_ROW_NUMBER":"910483","VIOLATION_NO":"7332446","ISSUE_DT":"01/07/2004","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"910482","VIOLATION_NO":"7332445","ISSUE_DT":"01/07/2004","CFR_STANDARD_CD":"75.1100-2(e)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"910481","VIOLATION_NO":"7332444","ISSUE_DT":"01/07/2004","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-07"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":387,"firstDate":"2000-01-03","lastDate":"2005-02-18","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":14,"validSamples":373,"maxConcentration":2.815,"concentrationTotal":197.372},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1626638","CASS_NUM":"50775666","SMP_TAKEN_DT":"2/18/2005","CONC":".577","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-18"},{"SOURCE_ROW_NUMBER":"1438575","CASS_NUM":"50775652","SMP_TAKEN_DT":"2/17/2005","CONC":".613","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-17"},{"SOURCE_ROW_NUMBER":"1556707","CASS_NUM":"50775650","SMP_TAKEN_DT":"2/16/2005","CONC":".506","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-16"},{"SOURCE_ROW_NUMBER":"282635","CASS_NUM":"50775663","SMP_TAKEN_DT":"2/15/2005","CONC":".593","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-15"},{"SOURCE_ROW_NUMBER":"273744","CASS_NUM":"50775664","SMP_TAKEN_DT":"2/14/2005","CONC":"1.046","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-14"},{"SOURCE_ROW_NUMBER":"1243946","CASS_NUM":"57543020","SMP_TAKEN_DT":"1/11/2005","CONC":".657","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"955978","CASS_NUM":"57455740","SMP_TAKEN_DT":"1/11/2005","CONC":".633","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"951500","CASS_NUM":"57455737","SMP_TAKEN_DT":"1/11/2005","CONC":".269","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"718198","CASS_NUM":"57455747","SMP_TAKEN_DT":"1/11/2005","CONC":".749","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"549649","CASS_NUM":"57542991","SMP_TAKEN_DT":"1/11/2005","CONC":".841","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"880674","CASS_NUM":"50775480","SMP_TAKEN_DT":"12/13/2004","CONC":".24","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-13"},{"SOURCE_ROW_NUMBER":"1432846","CASS_NUM":"50767164","SMP_TAKEN_DT":"11/5/2004","CONC":".46","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-05"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":8,"firstDate":"1997-11-01","lastDate":"1999-08-17","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":7},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":101,"firstDate":"2000-01-11","lastDate":"2005-12-01","metrics":{"inspectors":127,"recentRows":0,"onSiteHours":1103,"inspectionHours":1938.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1116477","EVENT_NO":"4154589","INSPECTION_BEGIN_DT":"12/01/2005","INSPECTION_END_DT":"01/10/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"144577","EVENT_NO":"4153381","INSPECTION_BEGIN_DT":"04/05/2005","INSPECTION_END_DT":"04/11/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2005-04-05"},{"SOURCE_ROW_NUMBER":"189760","EVENT_NO":"4402013","INSPECTION_BEGIN_DT":"03/14/2005","INSPECTION_END_DT":"03/14/2005","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2005-03-14"},{"SOURCE_ROW_NUMBER":"910907","EVENT_NO":"4150383","INSPECTION_BEGIN_DT":"01/10/2005","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"52.25","SUM_TOTAL_ON_SITE_HOURS":"27.75","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"252278","EVENT_NO":"4402085","INSPECTION_BEGIN_DT":"10/29/2004","INSPECTION_END_DT":"11/05/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-10-29"},{"SOURCE_ROW_NUMBER":"900049","EVENT_NO":"4150382","INSPECTION_BEGIN_DT":"10/04/2004","INSPECTION_END_DT":"12/20/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"58.5","SUM_TOTAL_ON_SITE_HOURS":"39","sourceDate":"2004-10-04"},{"SOURCE_ROW_NUMBER":"1049788","EVENT_NO":"4150928","INSPECTION_BEGIN_DT":"09/22/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"CBA","ACTIVITY":"ELECTRICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"15","sourceDate":"2004-09-22"},{"SOURCE_ROW_NUMBER":"600310","EVENT_NO":"4150653","INSPECTION_BEGIN_DT":"09/10/2004","INSPECTION_END_DT":"09/10/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2004-09-10"},{"SOURCE_ROW_NUMBER":"806579","EVENT_NO":"4150999","INSPECTION_BEGIN_DT":"08/23/2004","INSPECTION_END_DT":"09/21/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"74","SUM_TOTAL_ON_SITE_HOURS":"48.5","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"288984","EVENT_NO":"4150987","INSPECTION_BEGIN_DT":"06/09/2004","INSPECTION_END_DT":"06/18/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"591653","EVENT_NO":"4150982","INSPECTION_BEGIN_DT":"05/20/2004","INSPECTION_END_DT":"05/25/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2004-05-20"},{"SOURCE_ROW_NUMBER":"441727","EVENT_NO":"4150840","INSPECTION_BEGIN_DT":"05/11/2004","INSPECTION_END_DT":"05/25/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2004-05-11"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":42,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005-Q1":{"hours":3720,"employees":7,"production":9880},"2004-Q4":{"hours":3765,"employees":8,"production":7722},"2004-Q3":{"hours":3333,"employees":8,"production":6419},"2004-Q2":{"hours":4258,"employees":8,"production":9285},"2004-Q1":{"hours":4354,"employees":9,"production":8790},"2003-Q4":{"hours":4322,"employees":9,"production":8513},"2003-Q3":{"hours":4293,"employees":9,"production":10558},"2003-Q2":{"hours":4979,"employees":10,"production":14846},"2003-Q1":{"hours":4945,"employees":10,"production":11797},"2002-Q4":{"hours":4552,"employees":9,"production":11155},"2002-Q3":{"hours":4664,"employees":9,"production":10279},"2002-Q2":{"hours":4346,"employees":8,"production":14423}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":17376,"employees":9,"production":34667},"2001":{"hours":17589,"employees":8,"production":42311},"2002":{"hours":18031,"employees":9,"production":48176},"2003":{"hours":18539,"employees":10,"production":45714},"2004":{"hours":15710,"employees":8,"production":32216},"2005":{"hours":3720,"employees":7,"production":9880}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":31,"firstDate":"2000-04-06","lastDate":"2004-05-23","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":2013,"pelDoseTotal":1505},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"203170","EVENT_NO":"4150982","SURVEY_DATE":"05/23/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"040","ACT_DOSE_85":"62","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2004-05-23"},{"SOURCE_ROW_NUMBER":"203169","EVENT_NO":"4150982","SURVEY_DATE":"05/23/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"93","PEL_DOSE_90":"84","SURVEY_TYPE":"F","sourceDate":"2004-05-23"},{"SOURCE_ROW_NUMBER":"203168","EVENT_NO":"4150975","SURVEY_DATE":"04/22/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"148","PEL_DOSE_90":"139","SURVEY_TYPE":"I","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"203167","EVENT_NO":"4150975","SURVEY_DATE":"04/22/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"040","ACT_DOSE_85":"123","PEL_DOSE_90":"104","SURVEY_TYPE":"I","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"203166","EVENT_NO":"4150975","SURVEY_DATE":"04/22/2004","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"48","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"203165","EVENT_NO":"4150975","SURVEY_DATE":"04/22/2004","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"53","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"203176","EVENT_NO":"4153076","SURVEY_DATE":"10/09/2003","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"9","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2003-10-09"},{"SOURCE_ROW_NUMBER":"203164","EVENT_NO":"4150181","SURVEY_DATE":"11/01/2002","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2002-11-01"},{"SOURCE_ROW_NUMBER":"203163","EVENT_NO":"4150176","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"46","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"203162","EVENT_NO":"4150176","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"040","ACT_DOSE_85":"94","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"203161","EVENT_NO":"4150176","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"040","ACT_DOSE_85":"87","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2002-10-07"},{"SOURCE_ROW_NUMBER":"203160","EVENT_NO":"4150176","SURVEY_DATE":"10/07/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"66","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2002-10-07"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":34,"firstDate":"2000-01-11","lastDate":"2005-01-11","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":8.4,"validSamples":34,"quartzPctTotal":197.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"76823","CASSETTE_NO":"57455747","SAMPLE_DT":"01/11/2005","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-11"},{"SOURCE_ROW_NUMBER":"132371","CASSETTE_NO":"57528887","SAMPLE_DT":"10/12/2004","QUARTZ_PCT":"07.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-10-12"},{"SOURCE_ROW_NUMBER":"152938","CASSETTE_NO":"57455542","SAMPLE_DT":"08/24/2004","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-08-24"},{"SOURCE_ROW_NUMBER":"131216","CASSETTE_NO":"57455304","SAMPLE_DT":"06/09/2004","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"19205","CASSETTE_NO":"57455378","SAMPLE_DT":"06/09/2004","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"7620","CASSETTE_NO":"57455349","SAMPLE_DT":"06/09/2004","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"136679","CASSETTE_NO":"57456678","SAMPLE_DT":"04/22/2004","QUARTZ_PCT":"07.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"135412","CASSETTE_NO":"57456703","SAMPLE_DT":"04/22/2004","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"49108","CASSETTE_NO":"57456550","SAMPLE_DT":"07/01/2003","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-07-01"},{"SOURCE_ROW_NUMBER":"163201","CASSETTE_NO":"57456309","SAMPLE_DT":"04/28/2003","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-04-28"},{"SOURCE_ROW_NUMBER":"132762","CASSETTE_NO":"57415843","SAMPLE_DT":"07/03/2002","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-03"},{"SOURCE_ROW_NUMBER":"89211","CASSETTE_NO":"57415789","SAMPLE_DT":"07/03/2002","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-03"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":93,"firstDate":"2000-01-12","lastDate":"2005-12-01","metrics":{"ss":26,"amountDue":6332,"contested":0,"amountPaid":6332,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":6332},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2380336","VIOLATION_NO":"7311010","VIOLATION_ISSUE_DT":"12/01/2005","SIG_SUB":"N","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/09/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-01"},{"SOURCE_ROW_NUMBER":"2380307","VIOLATION_NO":"7340174","VIOLATION_ISSUE_DT":"09/14/2004","SIG_SUB":"N","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-09-14"},{"SOURCE_ROW_NUMBER":"2380292","VIOLATION_NO":"7339725","VIOLATION_ISSUE_DT":"05/04/2004","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-05-04"},{"SOURCE_ROW_NUMBER":"2380288","VIOLATION_NO":"7339785","VIOLATION_ISSUE_DT":"04/23/2004","SIG_SUB":"Y","PART_SECTION":"62.130(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/20/2004","PROPOSED_PENALTY":"135","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2004-04-23"},{"SOURCE_ROW_NUMBER":"2380273","VIOLATION_NO":"7332700","VIOLATION_ISSUE_DT":"04/20/2004","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-20"},{"SOURCE_ROW_NUMBER":"2380272","VIOLATION_NO":"7332693","VIOLATION_ISSUE_DT":"04/02/2004","SIG_SUB":"Y","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/02/2004","PROPOSED_PENALTY":"99","AMOUNT_DUE":"99","AMOUNT_PAID":"99","CONTESTED_IND":"N","sourceDate":"2004-04-02"},{"SOURCE_ROW_NUMBER":"2380271","VIOLATION_NO":"7332692","VIOLATION_ISSUE_DT":"04/02/2004","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/05/2004","PROPOSED_PENALTY":"99","AMOUNT_DUE":"99","AMOUNT_PAID":"99","CONTESTED_IND":"N","sourceDate":"2004-04-02"},{"SOURCE_ROW_NUMBER":"2380252","VIOLATION_NO":"7332448","VIOLATION_ISSUE_DT":"01/14/2004","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/14/2004","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2004-01-14"},{"SOURCE_ROW_NUMBER":"2380251","VIOLATION_NO":"7332447","VIOLATION_ISSUE_DT":"01/12/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-12"},{"SOURCE_ROW_NUMBER":"2380250","VIOLATION_NO":"7332446","VIOLATION_ISSUE_DT":"01/07/2004","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"2380249","VIOLATION_NO":"7332445","VIOLATION_ISSUE_DT":"01/07/2004","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"2380248","VIOLATION_NO":"7332444","VIOLATION_ISSUE_DT":"01/07/2004","SIG_SUB":"N","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-07"}]}],"safety":{"href":"/api/v1/mines/4406896/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406896/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 62.130","heading":"Permissible exposure level.","id":"62.130","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-M/part-62/section-62.130","part":"62","partHeading":"PART 62—OCCUPATIONAL NOISE EXPOSURE","subchapter":"M","subchapterHeading":"SUBCHAPTER M—UNIFORM MINE HEALTH REGULATIONS","subpart":"","subpartHeading":"","text":"(a) The mine operator must assure that no miner is exposed during any work shift to noise that exceeds the permissible exposure level. If during any work shift a miner's noise exposure exceeds the permissible exposure level, the mine operator must use all feasible engineering and administrative controls to reduce the miner's noise exposure to the permissible exposure level, and enroll the miner in a hearing conservation program that complies with § 62.150 of this part. When a mine operator uses administrative controls to reduce a miner's exposure, the mine operator must post the procedures for such controls on the mine bulletin board and provide a copy to the affected miner.\n\n(b) If a miner's noise exposure continues to exceed the permissible exposure level despite the use of all feasible engineering and administrative controls, the mine operator must continue to use the engineering and administrative controls to reduce the miner's noise exposure to as low a level as is feasible.\n\n(c) The mine operator must assure that no miner is exposed at any time to sound levels exceeding 115 dBA, as determined without adjustment for the use of any hearing protector.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406896","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}