{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4406851","name":"Black Creek #15 Strip","status":"Abandoned","status_date":"2004-11-02","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Norton","operator_id":"P10031","operator_name":"Steven R Mullins Excavating Inc","controller_id":"C07719","controller_name":"Steven R  Mullins","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":36.925,"longitude":-82.675},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":695},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406851","name":"Black Creek #15 Strip"},"operator":{"type":"operator","id":"P10031","name":"Steven R Mullins Excavating Inc"},"controller":{"type":"controller","id":"C07719","name":"Steven R  Mullins"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07719","name":"Steven R  Mullins"},"object":{"type":"mine","id":"4406851","name":"Black Creek #15 Strip"},"validFrom":"1979-10-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4406851|C07719|1979-10-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P10031","name":"Steven R Mullins Excavating Inc"},"object":{"type":"mine","id":"4406851","name":"Black Creek #15 Strip"},"validFrom":"1996-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4406851|P10031|1996-09-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07719","name":"Steven R  Mullins"},"object":{"type":"operator","id":"P10031","name":"Steven R Mullins Excavating Inc"},"validFrom":"1996-09-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406851","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4406851|P10031|1996-09-01|C07719|1979-10-01|75520"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":14,"firstDate":"2000-03-01","lastDate":"2004-07-23","metrics":{"daysLost":26,"injuries":14,"fatalities":0,"recentRows":0,"restrictedDays":7,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3401","DOCUMENT_NO":"220042160002","ACCIDENT_DT":"07/23/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was picking up and carrying metal brackets to install boggie pins in a D11 dozer's roller frame, when he pulled a muscle in his chest.","sourceDate":"2004-07-23"},{"SOURCE_ROW_NUMBER":"123491","DOCUMENT_NO":"220040230046","ACCIDENT_DT":"01/08/2004","DEGREE_INJURY":"NO VALUE FOUND","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"HE WAS REBUILDING D9N DOZER INSIDE SHOP WHEN HE GOT SOMETHING IN HIS EYE; DIDN'T KNOW WHERE HE GOT IT FROM","sourceDate":"2004-01-08"},{"SOURCE_ROW_NUMBER":"102032","DOCUMENT_NO":"220032390052","ACCIDENT_DT":"08/19/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","NARRATIVE":"HE WAS BUILDING A SAFETY STAND WHILE PUTTING IT TOGETHER HE STEPED ON A PIECE OF WOOD WITH A NAIL IN IT, RUNNING IT THREW HIS RIGHT FOOT.","sourceDate":"2003-08-19"},{"SOURCE_ROW_NUMBER":"227001","DOCUMENT_NO":"220031920027","ACCIDENT_DT":"06/30/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Truck driver","NO_INJURIES":"1","NARRATIVE":"HE WAS FILLING TANK WITH WATER. WENT TO GET DOWN OFF OF THE TRUCK AND THE PIECE OF METAL HE WAS HOLDING ONTO GAVE LOOSE, CAUSING HIM TO SLIP, CAUSING HIM TO HIT THE BACK OF THE TRUCK WITH HIS LEFT HIP AND CUTTING THE PALM OF HIS LEFT HAND.","sourceDate":"2003-06-30"},{"SOURCE_ROW_NUMBER":"136540","DOCUMENT_NO":"220031810047","ACCIDENT_DT":"06/25/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","NARRATIVE":"HE WAS USING A GRINDER WHILE WORKING ON A 992 BUCKET. SOMETHING GOT PAST HIS WELDING HELMET AND IN HIS LEFT EYE.","sourceDate":"2003-06-25"},{"SOURCE_ROW_NUMBER":"214108","DOCUMENT_NO":"220030870041","ACCIDENT_DT":"03/17/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"AFTER SERVICING D11N AS HE WAS GETTING OFF OF DOZER HE SLIPPED AND LEG WENT BETWEEN TRACK AND PUSH ARM.","sourceDate":"2003-03-17"},{"SOURCE_ROW_NUMBER":"158171","DOCUMENT_NO":"220030830080","ACCIDENT_DT":"03/11/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"DOZER BACKING UP IN RUN RIGHT TRACK WENT UP ON A ROCK DOZER TURNED OVER ON LEFT SIDE. SEAT BELT CAUGHT OPERATOR AROUND MIDDLE. TOOK HIM TO EMERGENCY ROOM TO BE CHECKED. THEY RELEASED HIM FROM EMERGENCY ROOM AROUND 4:00 AM ON 3/12/2003. EMERGENCY ROOM DR GAVE HIM A SLIP TO RETURN TO WORK ON 3/13/2003.","sourceDate":"2003-03-11"},{"SOURCE_ROW_NUMBER":"145193","DOCUMENT_NO":"220022750015","ACCIDENT_DT":"09/18/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"HE WAS REBUILDING ROLLER FRAMES FOR D11 TRACTOR. TAKING SNAP RINGS OUT OF BOGGIE PIN COVERS WHEN HE GOT A SMALL PIECE OF METAL IN HIS LEFT EYE.","sourceDate":"2002-09-18"},{"SOURCE_ROW_NUMBER":"106235","DOCUMENT_NO":"220021290019","ACCIDENT_DT":"04/17/2002","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","NARRATIVE":"HE WAS REPAIRING THE FRAME OPN A D11N TRACTOR. HE WAS PUTTING A PIECE OF METAL 35 X 26 X 3/4 IN PLACE AND HIT HIS KNEE AGAINST IT.","sourceDate":"2002-04-17"},{"SOURCE_ROW_NUMBER":"59118","DOCUMENT_NO":"220012980032","ACCIDENT_DT":"10/15/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"WALKED OUT OF SHOP GOING TO HIS SERVICE TRUCK THE WINDOR SOMETHING GOT SOMETHING IN HIS LEFT EYE","sourceDate":"2001-10-15"},{"SOURCE_ROW_NUMBER":"149608","DOCUMENT_NO":"220011970032","ACCIDENT_DT":"06/29/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"HE WAS PUTTING ROLLERS INTO EXCAVATOR BUCKET, SO HE COULD MOVE THEM CLOSER TO WHERE HE WAS WORKING. INJURY OCCURED WHEN HE WAS ROLLING A ROLLER INTO THE BUCKET.","sourceDate":"2001-06-29"},{"SOURCE_ROW_NUMBER":"153854","DOCUMENT_NO":"220010520008","ACCIDENT_DT":"02/09/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"9","NARRATIVE":"EE WAS INSTALLING RACES INTO 785 WHEEL HUB WITH PRESS. RACE WAS GOING IN CROOKED. TOOK 2 HAMMERSAND WAS USING THEM TO STRAIGHTEN THE RACE WHEN APIECE OF A HAMMER CAME OFF AND HIT HIM. METAL IM BEDDED INTO LEFT SIDE OF HEAD NEAR TEMPLE.","sourceDate":"2001-02-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-11-02","lastDate":"2004-11-02","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":33,"firstDate":"2000-09-11","lastDate":"2005-06-28","metrics":{"ss":16,"delinquent":32,"recentRows":0,"paidPenalty":3532,"proposedPenalty":3532,"currentAssessment":3532},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"925183","VIOLATION_NO":"7293062","ISSUE_DT":"06/28/2005","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-28"},{"SOURCE_ROW_NUMBER":"922585","VIOLATION_NO":"7339261","ISSUE_DT":"07/20/2004","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-20"},{"SOURCE_ROW_NUMBER":"922584","VIOLATION_NO":"7338999","ISSUE_DT":"07/14/2004","CFR_STANDARD_CD":"77.402","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"922583","VIOLATION_NO":"7338998","ISSUE_DT":"07/14/2004","CFR_STANDARD_CD":"77.410(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"922582","VIOLATION_NO":"7338997","ISSUE_DT":"07/14/2004","CFR_STANDARD_CD":"77.1710(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"922581","VIOLATION_NO":"7338996","ISSUE_DT":"07/14/2004","CFR_STANDARD_CD":"77.400(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"922580","VIOLATION_NO":"7338995","ISSUE_DT":"07/14/2004","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"203.00","CURRENT_ASSESSMENT_AMT":"203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"922579","VIOLATION_NO":"7338994","ISSUE_DT":"07/14/2004","CFR_STANDARD_CD":"77.205(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"922578","VIOLATION_NO":"7338993","ISSUE_DT":"07/14/2004","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"921161","VIOLATION_NO":"7334410","ISSUE_DT":"01/26/2004","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-26"},{"SOURCE_ROW_NUMBER":"921160","VIOLATION_NO":"7334409","ISSUE_DT":"01/26/2004","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-26"},{"SOURCE_ROW_NUMBER":"921159","VIOLATION_NO":"7334405","ISSUE_DT":"01/20/2004","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":55,"firstDate":"2000-01-12","lastDate":"2004-07-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":4,"validSamples":51,"maxConcentration":1.156,"concentrationTotal":13.328},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1462295","CASS_NUM":"57552744","SMP_TAKEN_DT":"7/14/2004","CONC":".082","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"1153932","CASS_NUM":"57552590","SMP_TAKEN_DT":"7/14/2004","CONC":".085","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"658469","CASS_NUM":"57552733","SMP_TAKEN_DT":"7/14/2004","CONC":".07","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"1237871","CASS_NUM":"57531042","SMP_TAKEN_DT":"1/15/2004","CONC":".28","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"918719","CASS_NUM":"57530580","SMP_TAKEN_DT":"1/15/2004","CONC":".049","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"555110","CASS_NUM":"57531053","SMP_TAKEN_DT":"1/15/2004","CONC":".239","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"411652","CASS_NUM":"57530596","SMP_TAKEN_DT":"1/15/2004","CONC":".389","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"271996","CASS_NUM":"57530593","SMP_TAKEN_DT":"1/15/2004","CONC":".568","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"1023804","CASS_NUM":"57519022","SMP_TAKEN_DT":"6/24/2003","CONC":".085","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-24"},{"SOURCE_ROW_NUMBER":"667013","CASS_NUM":"57519006","SMP_TAKEN_DT":"6/24/2003","CONC":".204","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-24"},{"SOURCE_ROW_NUMBER":"352055","CASS_NUM":"57518990","SMP_TAKEN_DT":"6/24/2003","CONC":".502","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-24"},{"SOURCE_ROW_NUMBER":"269712","CASS_NUM":"57518957","SMP_TAKEN_DT":"6/24/2003","CONC":".059","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-06-24"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":419,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":63,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1996-09-01","lastDate":"1996-09-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":32,"firstDate":"2000-01-12","lastDate":"2005-06-22","metrics":{"inspectors":32,"recentRows":0,"onSiteHours":370.75,"inspectionHours":497.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"401172","EVENT_NO":"4156765","INSPECTION_BEGIN_DT":"06/22/2005","INSPECTION_END_DT":"08/01/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.5","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2005-06-22"},{"SOURCE_ROW_NUMBER":"670098","EVENT_NO":"4156176","INSPECTION_BEGIN_DT":"01/24/2005","INSPECTION_END_DT":"02/16/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2005-01-24"},{"SOURCE_ROW_NUMBER":"779927","EVENT_NO":"4156123","INSPECTION_BEGIN_DT":"07/14/2004","INSPECTION_END_DT":"09/15/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"521199","EVENT_NO":"4156122","INSPECTION_BEGIN_DT":"07/14/2004","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"164990","EVENT_NO":"4156121","INSPECTION_BEGIN_DT":"07/13/2004","INSPECTION_END_DT":"09/08/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"17.5","sourceDate":"2004-07-13"},{"SOURCE_ROW_NUMBER":"51364","EVENT_NO":"4155594","INSPECTION_BEGIN_DT":"03/29/2004","INSPECTION_END_DT":"03/29/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2004-03-29"},{"SOURCE_ROW_NUMBER":"889954","EVENT_NO":"4155575","INSPECTION_BEGIN_DT":"01/15/2004","INSPECTION_END_DT":"02/26/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"925827","EVENT_NO":"4155574","INSPECTION_BEGIN_DT":"01/12/2004","INSPECTION_END_DT":"02/26/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"57","SUM_TOTAL_ON_SITE_HOURS":"42","sourceDate":"2004-01-12"},{"SOURCE_ROW_NUMBER":"421071","EVENT_NO":"4155558","INSPECTION_BEGIN_DT":"10/09/2003","INSPECTION_END_DT":"10/14/2003","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"3.25","sourceDate":"2003-10-09"},{"SOURCE_ROW_NUMBER":"530910","EVENT_NO":"4155210","INSPECTION_BEGIN_DT":"06/25/2003","INSPECTION_END_DT":"09/30/2003","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2003-06-25"},{"SOURCE_ROW_NUMBER":"728162","EVENT_NO":"4155209","INSPECTION_BEGIN_DT":"06/24/2003","INSPECTION_END_DT":"09/30/2003","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2003-06-24"},{"SOURCE_ROW_NUMBER":"673060","EVENT_NO":"4155208","INSPECTION_BEGIN_DT":"06/21/2003","INSPECTION_END_DT":"07/21/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"22","sourceDate":"2003-06-21"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":41968,"employees":55,"production":86630},"2002-Q3":{"hours":38451,"employees":65,"production":109735},"2002-Q2":{"hours":40135,"employees":57,"production":114824},"2002-Q1":{"hours":27352,"employees":49,"production":72206},"2001-Q4":{"hours":28169,"employees":40,"production":57480},"2001-Q3":{"hours":27822,"employees":44,"production":65425},"2001-Q2":{"hours":37912,"employees":62,"production":89660},"2001-Q1":{"hours":34810,"employees":64,"production":116020},"2000-Q4":{"hours":42857,"employees":70,"production":108372},"2000-Q3":{"hours":31893,"employees":60,"production":76240},"2000-Q2":{"hours":36600,"employees":58,"production":83986},"2000-Q1":{"hours":31492,"employees":58,"production":83377}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":142842,"employees":62,"production":351975},"2001":{"hours":128713,"employees":53,"production":328585},"2002":{"hours":147906,"employees":57,"production":383395},"2003":{"hours":142002,"employees":57,"production":366312},"2004":{"hours":91733,"employees":45,"production":208490}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":20,"firstDate":"2000-01-12","lastDate":"2004-07-14","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":860,"pelDoseTotal":509},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"202306","EVENT_NO":"4156122","SURVEY_DATE":"07/14/2004","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"73","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"202305","EVENT_NO":"4156122","SURVEY_DATE":"07/14/2004","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"33","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"202304","EVENT_NO":"4156122","SURVEY_DATE":"07/14/2004","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"45","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"202303","EVENT_NO":"4155210","SURVEY_DATE":"06/25/2003","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"71","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2003-06-25"},{"SOURCE_ROW_NUMBER":"202302","EVENT_NO":"4155210","SURVEY_DATE":"06/25/2003","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"119","ACT_DOSE_85":"41","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2003-06-25"},{"SOURCE_ROW_NUMBER":"202301","EVENT_NO":"4155210","SURVEY_DATE":"06/25/2003","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"28","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2003-06-25"},{"SOURCE_ROW_NUMBER":"202300","EVENT_NO":"4155210","SURVEY_DATE":"06/25/2003","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"17","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2003-06-25"},{"SOURCE_ROW_NUMBER":"202299","EVENT_NO":"4155104","SURVEY_DATE":"06/05/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"61","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2002-06-05"},{"SOURCE_ROW_NUMBER":"202298","EVENT_NO":"4155104","SURVEY_DATE":"06/05/2002","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"21","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2002-06-05"},{"SOURCE_ROW_NUMBER":"202297","EVENT_NO":"4155104","SURVEY_DATE":"06/05/2002","OCCUPATION_CD_DESC":"STRIPPING SHOVEL OPERATOR","MACHINE_CD":"35","MANUFACTURER_CD":"063","ACT_DOSE_85":"8","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2002-06-05"},{"SOURCE_ROW_NUMBER":"202296","EVENT_NO":"4155104","SURVEY_DATE":"06/05/2002","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"119","ACT_DOSE_85":"7","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2002-06-05"},{"SOURCE_ROW_NUMBER":"202295","EVENT_NO":"4155104","SURVEY_DATE":"06/05/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"87","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2002-06-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":6,"firstDate":"2000-01-12","lastDate":"2002-01-15","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":49.3,"validSamples":5,"quartzPctTotal":113.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"85184","CASSETTE_NO":"50635194","SAMPLE_DT":"01/15/2002","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"43274","CASSETTE_NO":"57397291","SAMPLE_DT":"12/18/2001","QUARTZ_PCT":"49.3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"90780","CASSETTE_NO":"57323368","SAMPLE_DT":"01/29/2001","QUARTZ_PCT":"17.8","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-29"},{"SOURCE_ROW_NUMBER":"108658","CASSETTE_NO":"57296587","SAMPLE_DT":"09/15/2000","QUARTZ_PCT":"24.9","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-09-15"},{"SOURCE_ROW_NUMBER":"154995","CASSETTE_NO":"57219332","SAMPLE_DT":"01/12/2000","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-01-12"},{"SOURCE_ROW_NUMBER":"46927","CASSETTE_NO":"57219346","SAMPLE_DT":"01/12/2000","QUARTZ_PCT":"15.5","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-01-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":33,"firstDate":"2000-09-11","lastDate":"2005-06-28","metrics":{"ss":16,"amountDue":3532,"contested":0,"amountPaid":3532,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":3532},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2371743","VIOLATION_NO":"7293062","VIOLATION_ISSUE_DT":"06/28/2005","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/28/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-06-28"},{"SOURCE_ROW_NUMBER":"2371751","VIOLATION_NO":"7339261","VIOLATION_ISSUE_DT":"07/20/2004","SIG_SUB":"N","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-07-20"},{"SOURCE_ROW_NUMBER":"2371750","VIOLATION_NO":"7338999","VIOLATION_ISSUE_DT":"07/14/2004","SIG_SUB":"N","PART_SECTION":"77.402","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"2371749","VIOLATION_NO":"7338998","VIOLATION_ISSUE_DT":"07/14/2004","SIG_SUB":"N","PART_SECTION":"77.410(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"2371748","VIOLATION_NO":"7338997","VIOLATION_ISSUE_DT":"07/14/2004","SIG_SUB":"N","PART_SECTION":"77.1710(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"2371747","VIOLATION_NO":"7338996","VIOLATION_ISSUE_DT":"07/14/2004","SIG_SUB":"N","PART_SECTION":"77.400(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"2371746","VIOLATION_NO":"7338995","VIOLATION_ISSUE_DT":"07/14/2004","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2004","PROPOSED_PENALTY":"203","AMOUNT_DUE":"203","AMOUNT_PAID":"203","CONTESTED_IND":"N","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"2371745","VIOLATION_NO":"7338994","VIOLATION_ISSUE_DT":"07/14/2004","SIG_SUB":"Y","PART_SECTION":"77.205(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2004","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"N","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"2371744","VIOLATION_NO":"7338993","VIOLATION_ISSUE_DT":"07/14/2004","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2004","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2004-07-14"},{"SOURCE_ROW_NUMBER":"2371729","VIOLATION_NO":"7334410","VIOLATION_ISSUE_DT":"01/26/2004","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/26/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-26"},{"SOURCE_ROW_NUMBER":"2371728","VIOLATION_NO":"7334409","VIOLATION_ISSUE_DT":"01/26/2004","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/04/2004","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2004-01-26"},{"SOURCE_ROW_NUMBER":"2371727","VIOLATION_NO":"7334405","VIOLATION_ISSUE_DT":"01/20/2004","SIG_SUB":"Y","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/22/2004","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2004-01-20"}]}],"safety":{"href":"/api/v1/mines/4406851/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406851/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","heading":"Hand-held power tools; safety devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.402","part":"77","subchapter":"O","subpart":"E","id":"77.402","citation":"30 CFR 77.402","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406851","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}