{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4406846","name":"Deep Mine #27","status":"Abandoned","status_date":"2004-08-26","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Wise, Va","operator_id":"0050885","operator_name":"Paramont Coal Company Virginia, LLC","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.034444,"longitude":-82.435},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1858},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"operator":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00230","name":"Pittston Company"},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"1986-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|C00230|1986-06-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"1994-07-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|C07082|1994-07-01|2010-04-18"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22858","name":"Dorchester Enterprises Inc"},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"1996-08-01","validTo":"1998-02-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|P22858|1996-08-01|1998-02-19"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P22858","name":"Dorchester Enterprises Inc"},"validFrom":"1996-08-01","validTo":"1998-02-19","current":false,"derived":true,"evidenceMineId":"4406846","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|P22858|1996-08-01|C07082|1994-07-01|73687"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17909","name":"Paramont Coal Corp"},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"1998-02-20","validTo":"2002-12-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|P17909|1998-02-20|2002-12-12"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00230","name":"Pittston Company"},"object":{"type":"operator","id":"P17909","name":"Paramont Coal Corp"},"validFrom":"1998-02-20","validTo":"2002-12-12","current":false,"derived":true,"evidenceMineId":"4406846","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|P17909|1998-02-20|C00230|1986-06-01|45331"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"2002-12-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|0050885|2002-12-13|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"2002-12-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|0041211|2002-12-13|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"validFrom":"2002-12-13","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406846","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|0050885|2002-12-13|0041211|2002-12-13|1587"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|C02508|2010-04-19|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22858","name":"Dorchester Enterprises Inc"},"validFrom":"2010-04-19","validTo":"1998-02-19","current":false,"derived":true,"evidenceMineId":"4406846","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|P22858|1996-08-01|C02508|2010-04-19|59592"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4406846","name":"Deep Mine #27"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22858","name":"Dorchester Enterprises Inc"},"validFrom":"2011-06-01","validTo":"1998-02-19","current":false,"derived":true,"evidenceMineId":"4406846","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406846|P22858|1996-08-01|0041211|2011-06-01|2291"}}],"coverage":{"historyRecords":5,"edgeCount":13,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":46,"firstDate":"2000-01-19","lastDate":"2004-04-15","metrics":{"daysLost":639,"injuries":25,"fatalities":0,"recentRows":0,"restrictedDays":83,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"59117","DOCUMENT_NO":"220041200050","ACCIDENT_DT":"04/15/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"59","NARRATIVE":"EE WAS LOADING ROCK DUST ONTO SCOOP WHEN HE FELT PAIN IN HIS LOWER BACK.","sourceDate":"2004-04-15"},{"SOURCE_ROW_NUMBER":"85019","DOCUMENT_NO":"220040820029","ACCIDENT_DT":"03/03/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was sliding a belt starter box onto a flat car, when his left middle finger got caught between the start box and the flat car. he was taken to a local E.R. where he received stitches to his finger.","sourceDate":"2004-03-03"},{"SOURCE_ROW_NUMBER":"114995","DOCUMENT_NO":"220040540047","ACCIDENT_DT":"02/10/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"EE WAS TAKING DOWN A SAILBOAT BASE WHEN ONE END THAT HAD BEEN PARTIALLY LOOSENED FELL DOWN CAUSING THE OTHER END TO CATCH TWO OF HIS FINGERS OF THE LEFT HAND BETWEEN THE MINE ROOF & THE BASE, CAUSING A LACERATION TO BOTH FINGERS.","sourceDate":"2004-02-10"},{"SOURCE_ROW_NUMBER":"16216","DOCUMENT_NO":"220040430022","ACCIDENT_DT":"02/04/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL OCCURRED MEASURING 35' LONG BY 25' WIDE AND 6' HIGH AT APPROX 4900' OUT BY THE FACE AREA AT SPAD NO. 11649. A FAIRCHILD SCOOP WAS CAUGHT MODEL NO. 266. NO VENTILATION WAS DISTURBED, NO INJURY OCCURRED AND THE FALL WILL NOT BE CLEANED UP.","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"123486","DOCUMENT_NO":"220033210043","ACCIDENT_DT":"11/08/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL OCCURRED MEASURING 20'LONG X 20'WIDE WITH AN UNDETERMINED HEIGHT BEGINNING AT T-PANEL #9 ENTRY IN INTERSECTION AT SPAD 13206. NO EQUIPMENT WAS INVOLVED, NO VENTILATION WAS DISTURBE D, NO INJURY OCCURRED, AND THE FALL WILL NOT BE CLEANED UP.","sourceDate":"2003-11-08"},{"SOURCE_ROW_NUMBER":"106233","DOCUMENT_NO":"220032750036","ACCIDENT_DT":"09/26/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"78","NARRATIVE":"THE EMPLOYEE HAD BEEN HELPING TO REMOVE A ROCK OFF OF THE CONTINUOUS MINING MACHINE. AFTER GETTING THE ROCK INTO THE CONVEYOR PAN THE EMPLOYEE POSITIONED HIMSELF APPROXIMATELY 7 FT AWAY IN A C ROSSCUT. AT THIS TIME THE MINER OPERATOR LOWERED THE HEAD OF THE MINER DOWN AGAINST THE ROCK TO BREAK UT CAUSING A PIECE OF THE ROCK TO FLIP OUT OF THE PAN ONTO EE'S LEFT LEG CAUSING FRACTURE","sourceDate":"2003-09-26"},{"SOURCE_ROW_NUMBER":"140936","DOCUMENT_NO":"220032750037","ACCIDENT_DT":"09/22/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL WAS DISCOVERED IN THE #4 THRU 7 ENTRIES OF S PANEL AT SS#13071, 13076, 13082, 13080. THE FALL WAS APPROXIMATELY 1800 FT OFF THE ACTIVE SECTION AND MEASURED APPROXIMATELY 230 FT X 1 9FT WIDE AND UNKNOWN HEIGHT. THE AREA HAS BEEN DANGERED OFF AND WILL NOT BE CLEANED UP. VENTILATION OR TRAVEL WAS NOT AFFECTED AND NO INJURIES WERE REPORTED.","sourceDate":"2003-09-22"},{"SOURCE_ROW_NUMBER":"175365","DOCUMENT_NO":"220032650020","ACCIDENT_DT":"09/15/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL WAS DISCOVERED BEGINNING AT #6 ENTRY50'INBY SPAD #10058 IN THE INTERSECTION 40'LONG X19'WIDE X 7'HIGH 9600'OUTBY WORKING SECTION.AREA SUPPORTED WITH 48\" RESIN BOLTS. NO VENTILATION WAS DISTURBED, NO INJURY OCCURRED AND THE FALL WILL NOT BE CLEANED UP AND FALL WILL NOT BE CLEANED UP, NO EQUIPMENT WAS INVOLVED.","sourceDate":"2003-09-15"},{"SOURCE_ROW_NUMBER":"97769","DOCUMENT_NO":"220032750035","ACCIDENT_DT":"09/15/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"73","NARRATIVE":"THE EMPLOYEE WAS RIDING THE MANTRIP TO THE OUTSIDE, WHEN THE MOTOR BOTTOMED OUT IN A DIP CAUSING THE EMPLOYEE PAIN IN HIS LOWER BACK. THE EMPLOYEE HAD 4 CONSECUTIVE DAYS OFF FOLLOWING THE INCI DENT AND UPON RETURNING TO WORK ON THE NEXT REGULAR CYCLE HE STATED THAT HE WAS NOT GOING TO BE ABLE TO MAKE IT AND WANTED TO GO SEE A DOCTOR. EMPLOYEE WAS PLACED ON WORK RESTRICTIONS.","sourceDate":"2003-09-15"},{"SOURCE_ROW_NUMBER":"63394","DOCUMENT_NO":"220032650049","ACCIDENT_DT":"09/13/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A PILLAR FALL OCCURRED ON THE 001 SECTION ON PANEL 5 IN #3 ENTRY 70' INBY SPAD #13028. THE JM-6 MINER WAS CAUGHT IN THE END CUT WHEN UNDETECTED SLIP FELL ON THE MINER. THE FALL WAS APPROX 18'W IDE X 0\" - 8' THICK, LENGTH UNDETERMINED DUE TO EXTRACTION OF PILLARS. VENTILATION NOT AFFECTED. NO INJURIES WERE REPORTED AND THE FALL WAS NOT CLEANED UP.","sourceDate":"2003-09-13"},{"SOURCE_ROW_NUMBER":"132146","DOCUMENT_NO":"220032590019","ACCIDENT_DT":"09/06/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A PILLAR FALL OCCURRED ON THE 001 SECTION IN THE #4 ENTRY APPROX 90' INBY SS #12818. THE FALL CAUGHT THE HEAD OF THE CONT MINING MACHINE AND WOULD NOT ALLOW THE MACHINE TO BACK OUT OF THE C UT.","sourceDate":"2003-09-06"},{"SOURCE_ROW_NUMBER":"248544","DOCUMENT_NO":"220032190032","ACCIDENT_DT":"07/29/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"57","NARRATIVE":"THE ALLEGED INJURY WAS TO HAVE OCCURRED WHILE THE EE & HIS HELPER WERE IN THE PROCESS OF INSTALLING TIMBERS & COLLARS. AS THE EE WAS IN THE PROCESS OF SETTING TIMBERS, AN UNDETECTED PIECE OF D RAW ROCK FELL FROM BETWEEN PERMANENT SUPPORTS IMPACTING THE EE ON TOP OF HIS HARD HAT. THE ROCK MEASURED 24\" X 17\" X 0-8\" THICK & THE OVERALL HEIGHT OF THE AREA WAS 8'4\" HIGH & EE'S APPROXIMA","sourceDate":"2003-07-29"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-08-26","lastDate":"2004-08-26","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":139,"firstDate":"2000-03-02","lastDate":"2004-07-22","metrics":{"ss":55,"delinquent":131,"recentRows":0,"paidPenalty":14818,"proposedPenalty":15034,"currentAssessment":15034},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"918559","VIOLATION_NO":"7335730","ISSUE_DT":"07/22/2004","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"153.00","CURRENT_ASSESSMENT_AMT":"153.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-07-22"},{"SOURCE_ROW_NUMBER":"918548","VIOLATION_NO":"7335699","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918547","VIOLATION_NO":"7335698","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918546","VIOLATION_NO":"7335697","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918545","VIOLATION_NO":"7335696","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"77.410(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918544","VIOLATION_NO":"7335695","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918543","VIOLATION_NO":"7335694","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"268.00","CURRENT_ASSESSMENT_AMT":"268.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918542","VIOLATION_NO":"7335693","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"75.340(a)(1)(i)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"268.00","CURRENT_ASSESSMENT_AMT":"268.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918541","VIOLATION_NO":"7335692","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918540","VIOLATION_NO":"7335691","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918539","VIOLATION_NO":"7335690","ISSUE_DT":"06/04/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"918538","VIOLATION_NO":"7335682","ISSUE_DT":"05/17/2004","CFR_STANDARD_CD":"77.1107","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-05-17"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3,"firstDate":"2004-12-20","lastDate":"2004-12-20","metrics":{"appeals":0,"decisions":3,"recentRows":0,"decisionPenalty":216,"originalPenalty":216},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"184615","VIOLATION_NO":"7335695","DOCKET_NO":"VA 2004-52","DECISION_DT":"12/20/2004","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"72.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-20"},{"SOURCE_ROW_NUMBER":"2563","VIOLATION_NO":"7335697","DOCKET_NO":"VA 2004-52","DECISION_DT":"12/20/2004","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"72.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-20"},{"SOURCE_ROW_NUMBER":"2457","VIOLATION_NO":"7335696","DOCKET_NO":"VA 2004-52","DECISION_DT":"12/20/2004","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"72.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-12-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":790,"firstDate":"2000-01-05","lastDate":"2004-06-08","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":24,"validSamples":766,"maxConcentration":6.332,"concentrationTotal":561.242},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1532754","CASS_NUM":"57553144","SMP_TAKEN_DT":"6/8/2004","CONC":".574","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"1328938","CASS_NUM":"57553114","SMP_TAKEN_DT":"6/8/2004","CONC":".604","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"433764","CASS_NUM":"57552810","SMP_TAKEN_DT":"6/8/2004","CONC":".273","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"139442","CASS_NUM":"57552756","SMP_TAKEN_DT":"6/8/2004","CONC":".244","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"35568","CASS_NUM":"57552790","SMP_TAKEN_DT":"6/8/2004","CONC":".696","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"31423","CASS_NUM":"57552935","SMP_TAKEN_DT":"6/8/2004","CONC":".404","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"1467582","CASS_NUM":"50749482","SMP_TAKEN_DT":"5/19/2004","CONC":".421","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-19"},{"SOURCE_ROW_NUMBER":"1342531","CASS_NUM":"50749523","SMP_TAKEN_DT":"5/18/2004","CONC":".192","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"444324","CASS_NUM":"50749506","SMP_TAKEN_DT":"5/18/2004","CONC":".23","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"1568660","CASS_NUM":"50749508","SMP_TAKEN_DT":"5/17/2004","CONC":".188","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-17"},{"SOURCE_ROW_NUMBER":"269838","CASS_NUM":"50749474","SMP_TAKEN_DT":"5/17/2004","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-17"},{"SOURCE_ROW_NUMBER":"1662793","CASS_NUM":"50740090","SMP_TAKEN_DT":"5/12/2004","CONC":"1.191","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-12"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2000-10-18","lastDate":"2004-08-10","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":3,"firstDate":"2004-06-04","lastDate":"2004-06-04","metrics":{"decisions":3,"ssChanged":3,"recentRows":0,"decisionPenalty":216,"proposedPenalty":216},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"339093","CITATION_NO":"7335696","CITATION_ISSUE_DT":"06/04/2004","DOCKET_NO":"VA 2004-52","DECISION_DT":"12/20/2004","CFR_STANDARD_CODE":"77.410(b)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"72.00","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"169369","CITATION_NO":"7335695","CITATION_ISSUE_DT":"06/04/2004","DOCKET_NO":"VA 2004-52","DECISION_DT":"12/20/2004","CFR_STANDARD_CODE":"77.1109(c)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"72.00","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"113099","CITATION_NO":"7335697","CITATION_ISSUE_DT":"06/04/2004","DOCKET_NO":"VA 2004-52","DECISION_DT":"12/20/2004","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"72.00","sourceDate":"2004-06-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":322,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":70,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1996-08-01","lastDate":"2002-12-13","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":132,"firstDate":"2000-03-01","lastDate":"2004-07-07","metrics":{"inspectors":165,"recentRows":0,"onSiteHours":1817.5,"inspectionHours":2982.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1124412","EVENT_NO":"4132435","INSPECTION_BEGIN_DT":"07/07/2004","INSPECTION_END_DT":"07/08/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-07-07"},{"SOURCE_ROW_NUMBER":"869850","EVENT_NO":"4154727","INSPECTION_BEGIN_DT":"07/01/2004","INSPECTION_END_DT":"08/31/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2004-07-01"},{"SOURCE_ROW_NUMBER":"768453","EVENT_NO":"4127369","INSPECTION_BEGIN_DT":"06/22/2004","INSPECTION_END_DT":"06/22/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2004-06-22"},{"SOURCE_ROW_NUMBER":"913868","EVENT_NO":"4154726","INSPECTION_BEGIN_DT":"06/03/2004","INSPECTION_END_DT":"06/09/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-06-03"},{"SOURCE_ROW_NUMBER":"353208","EVENT_NO":"4155968","INSPECTION_BEGIN_DT":"04/27/2004","INSPECTION_END_DT":"05/05/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-04-27"},{"SOURCE_ROW_NUMBER":"771277","EVENT_NO":"4155959","INSPECTION_BEGIN_DT":"04/05/2004","INSPECTION_END_DT":"04/12/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-04-05"},{"SOURCE_ROW_NUMBER":"507306","EVENT_NO":"4154722","INSPECTION_BEGIN_DT":"04/01/2004","INSPECTION_END_DT":"06/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"122.75","SUM_TOTAL_ON_SITE_HOURS":"77","sourceDate":"2004-04-01"},{"SOURCE_ROW_NUMBER":"1105568","EVENT_NO":"4155955","INSPECTION_BEGIN_DT":"03/24/2004","INSPECTION_END_DT":"03/31/2004","ACTIVITY_CODE":"CBD","ACTIVITY":"RESPIRABLE DUST MONITORING INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-03-24"},{"SOURCE_ROW_NUMBER":"820797","EVENT_NO":"4155950","INSPECTION_BEGIN_DT":"03/15/2004","INSPECTION_END_DT":"03/23/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-03-15"},{"SOURCE_ROW_NUMBER":"880932","EVENT_NO":"4154528","INSPECTION_BEGIN_DT":"02/20/2004","INSPECTION_END_DT":"03/01/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-02-20"},{"SOURCE_ROW_NUMBER":"168463","EVENT_NO":"4155941","INSPECTION_BEGIN_DT":"02/19/2004","INSPECTION_END_DT":"03/04/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"185052","EVENT_NO":"4127230","INSPECTION_BEGIN_DT":"02/09/2004","INSPECTION_END_DT":"02/20/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2004-02-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":44,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q3":{"hours":0,"employees":0,"production":0},"2004-Q2":{"hours":24085,"employees":55,"production":59019},"2004-Q1":{"hours":31776,"employees":58,"production":83125},"2003-Q4":{"hours":37451,"employees":58,"production":98018},"2003-Q3":{"hours":49948,"employees":106,"production":170166},"2003-Q2":{"hours":51055,"employees":89,"production":146674},"2003-Q1":{"hours":51625,"employees":91,"production":126014},"2002-Q4":{"hours":42110,"employees":91,"production":137817},"2002-Q3":{"hours":42366,"employees":80,"production":107452},"2002-Q2":{"hours":38415,"employees":77,"production":89093},"2002-Q1":{"hours":42335,"employees":78,"production":93725},"2001-Q4":{"hours":40181,"employees":76,"production":104394}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":165451,"employees":77,"production":568538},"2001":{"hours":164600,"employees":76,"production":419420},"2002":{"hours":165226,"employees":82,"production":428087},"2003":{"hours":190079,"employees":88,"production":540872},"2004":{"hours":55861,"employees":57,"production":142144}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":44,"firstDate":"2000-04-17","lastDate":"2004-06-04","metrics":{"recentRows":0,"doseOver100":8,"actDoseTotal":3699,"pelDoseTotal":2722},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"202191","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"62","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202190","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"51","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202189","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"80","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202188","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"92","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202187","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"80","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202186","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202185","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (MOUNTED) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"92","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202184","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"CUTTING MACHINE HELPER","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"80","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202183","EVENT_NO":"4154726","SURVEY_DATE":"06/04/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"202181","EVENT_NO":"4138782","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"28","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"202180","EVENT_NO":"4138782","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"54","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"202179","EVENT_NO":"4138782","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"53","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2003-09-11"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":99,"firstDate":"2000-03-02","lastDate":"2004-06-08","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":13.3,"validSamples":96,"quartzPctTotal":618.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"106312","CASSETTE_NO":"57552790","SAMPLE_DT":"06/08/2004","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"58150","CASSETTE_NO":"57553114","SAMPLE_DT":"06/08/2004","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"36062","CASSETTE_NO":"57553144","SAMPLE_DT":"06/08/2004","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"33582","CASSETTE_NO":"50740059","SAMPLE_DT":"05/12/2004","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-12"},{"SOURCE_ROW_NUMBER":"59753","CASSETTE_NO":"57529432","SAMPLE_DT":"04/05/2004","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-05"},{"SOURCE_ROW_NUMBER":"130918","CASSETTE_NO":"57529211","SAMPLE_DT":"02/23/2004","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"140900","CASSETTE_NO":"57531024","SAMPLE_DT":"01/20/2004","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-20"},{"SOURCE_ROW_NUMBER":"98199","CASSETTE_NO":"57531054","SAMPLE_DT":"01/20/2004","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-20"},{"SOURCE_ROW_NUMBER":"7557","CASSETTE_NO":"57531018","SAMPLE_DT":"01/20/2004","QUARTZ_PCT":"08.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-20"},{"SOURCE_ROW_NUMBER":"122853","CASSETTE_NO":"57491898","SAMPLE_DT":"10/27/2003","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-10-27"},{"SOURCE_ROW_NUMBER":"112089","CASSETTE_NO":"57491907","SAMPLE_DT":"10/27/2003","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-10-27"},{"SOURCE_ROW_NUMBER":"109073","CASSETTE_NO":"57491854","SAMPLE_DT":"10/27/2003","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-10-27"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":141,"firstDate":"2000-03-02","lastDate":"2004-07-22","metrics":{"ss":55,"amountDue":15034,"contested":3,"amountPaid":14818,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":15034},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2370540","VIOLATION_NO":"7335730","VIOLATION_ISSUE_DT":"07/22/2004","SIG_SUB":"Y","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/22/2004","PROPOSED_PENALTY":"153","AMOUNT_DUE":"153","AMOUNT_PAID":"153","CONTESTED_IND":"N","sourceDate":"2004-07-22"},{"SOURCE_ROW_NUMBER":"2370509","VIOLATION_NO":"7335699","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/04/2004","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370508","VIOLATION_NO":"7335698","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/08/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370507","VIOLATION_NO":"7335697","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/10/2004","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"VA 2004-52","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370506","VIOLATION_NO":"7335696","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"Y","PART_SECTION":"77.410(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/10/2004","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"VA 2004-52","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370505","VIOLATION_NO":"7335695","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"Y","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/10/2004","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"VA 2004-52","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370504","VIOLATION_NO":"7335694","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2004","PROPOSED_PENALTY":"268","AMOUNT_DUE":"268","AMOUNT_PAID":"268","CONTESTED_IND":"N","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370503","VIOLATION_NO":"7335693","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"Y","PART_SECTION":"75.340(a)(1)(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2004","PROPOSED_PENALTY":"268","AMOUNT_DUE":"268","AMOUNT_PAID":"268","CONTESTED_IND":"N","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370502","VIOLATION_NO":"7335692","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370501","VIOLATION_NO":"7335691","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/08/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370500","VIOLATION_NO":"7335690","VIOLATION_ISSUE_DT":"06/04/2004","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/08/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"2370499","VIOLATION_NO":"7335682","VIOLATION_ISSUE_DT":"05/17/2004","SIG_SUB":"N","PART_SECTION":"77.1107","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-05-17"}]}],"safety":{"href":"/api/v1/mines/4406846/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406846/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.31","part":"48","subchapter":"H","subpart":"B","id":"48.31","citation":"30 CFR 48.31","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","heading":"Underground electrical installations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.340","part":"75","subchapter":"O","subpart":"D","id":"75.340","citation":"30 CFR 75.340","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Belt conveyors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1107","part":"77","subchapter":"O","subpart":"L","id":"77.1107","citation":"30 CFR 77.1107","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406846","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}