{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4406807","name":"Guest Mountain Mine No 2","status":"Abandoned and Sealed","status_date":"2005-05-20","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Coeburn","operator_id":"0050885","operator_name":"Paramont Coal Company Virginia, LLC","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":36.975833,"longitude":-82.418611},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1157},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"operator":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01883","name":"El Paso Energy Corp"},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"1989-04-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|C01883|1989-04-04|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"1993-03-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|C07082|1993-03-01|2010-04-18"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corp"},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"1995-09-01","validTo":"1997-05-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|P22270|1995-09-01|1997-05-26"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corp"},"validFrom":"1995-09-01","validTo":"1997-05-26","current":false,"derived":true,"evidenceMineId":"4406807","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|P22270|1995-09-01|C07082|1993-03-01|73675"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24015","name":"Coastal Coal Company, LLC"},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"1997-05-27","validTo":"2003-01-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|P24015|1997-05-27|2003-01-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01883","name":"El Paso Energy Corp"},"object":{"type":"operator","id":"P24015","name":"Coastal Coal Company, LLC"},"validFrom":"1997-05-27","validTo":"2003-01-31","current":false,"derived":true,"evidenceMineId":"4406807","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|P24015|1997-05-27|C01883|1989-04-04|56678"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"2002-12-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|0041211|2002-12-13|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"2003-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|0050885|2003-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0050885","name":"Paramont Coal Company Virginia, LLC"},"validFrom":"2003-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406807","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|0050885|2003-02-01|0041211|2002-12-13|1584"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|C02508|2010-04-19|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corp"},"validFrom":"2010-04-19","validTo":"1997-05-26","current":false,"derived":true,"evidenceMineId":"4406807","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|P22270|1995-09-01|C02508|2010-04-19|59590"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4406807","name":"Guest Mountain Mine No 2"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corp"},"validFrom":"2011-06-01","validTo":"1997-05-26","current":false,"derived":true,"evidenceMineId":"4406807","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406807|P22270|1995-09-01|0041211|2011-06-01|2289"}}],"coverage":{"historyRecords":5,"edgeCount":13,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":23,"firstDate":"2000-03-02","lastDate":"2004-02-24","metrics":{"daysLost":604,"injuries":13,"fatalities":0,"recentRows":0,"restrictedDays":4,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"123482","DOCUMENT_NO":"220042370020","ACCIDENT_DT":"02/24/2004","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"A piece of rock fell from overhead causing a small cut to his right cheek. when cheek healed the scar showed black demarcation. the employee requested that the discoloration be removed by plastic surgery, making this reportable as of 8-12-04.","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"158159","DOCUMENT_NO":"220040430028","ACCIDENT_DT":"01/08/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"EMPLOYEE WAS LIFTING A PUMP OUT OF A CONTINUOUS MINER WHEN HE FELT PAIN IN HIS GROIN. HE FINISHED HIS SHIFT WITHOUT ANY PROBLEM AND WORKED UNTIL THE 30TH OF JANUARY WITHOUT MISSING A SHIFT. HE SOUGHT MEDICAL ATTENTION ON JAN. 28 AT WHICH TIME HE WAS TOLD HE HAD A HERNIA AND WOULD NEED SURGERY. HE WORKED UNTIL THE DAY OF THE SURGERY - JAN. 30, 2004 (THE DAY LOST TIME BEGAN).","sourceDate":"2004-01-08"},{"SOURCE_ROW_NUMBER":"201065","DOCUMENT_NO":"220032650056","ACCIDENT_DT":"09/10/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL OCCURRED MEASURING 18'WIDE X 80'LONG X 8-10'HIGH BEGINNING LEFT OF SPAD #3997 (40' TO THE LEFT). NO EQUIPMENT WAS INVOLVED. NO VENTILATION WAS DISTURBED. NO INJURY OCCURRED AND THE FALL WILL NOT BE CLEANED UP.","sourceDate":"2003-09-10"},{"SOURCE_ROW_NUMBER":"89291","DOCUMENT_NO":"220032450111","ACCIDENT_DT":"08/06/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL OCCURRED MEASURING 20' WIDE BY 10' HIGH BY 260' LONG BEGINNING AT THE NO.7 AND NO.8 ENTRY. THE TOP STARTED WORKING ON THE 2ND SHIFT AND WAS CRIBBED AND THEN CENTER CRIBBED DOWN THE ENTRY. IT BEGAN WORKING AGAIN ON THE 3RD SHIFT AND MORE CRIBS WERE ADDED, BUT AT 4:00 AM IT FELL.","sourceDate":"2003-08-06"},{"SOURCE_ROW_NUMBER":"76472","DOCUMENT_NO":"220031880083","ACCIDENT_DT":"06/22/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"258","NARRATIVE":"WHILE WORKING TO REPLACE THE COUPLING BETWEEN THE MOTOR AND SPEED REDUCER ON THE BELT LINE HIS FOOT SLIPPED CAUSING A TWIST TO HIS RIGHT KNEE.","sourceDate":"2003-06-22"},{"SOURCE_ROW_NUMBER":"192507","DOCUMENT_NO":"220031780044","ACCIDENT_DT":"06/16/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL OCCURRED MEASURING 30' BY 40' BY 7' BEGINNING AT #4 ENTRY RIGHT OF SPAD 3809. NO EQUIPMENT WAS INVOLVED. NO VENTILATION WAS DISTURBED, NO INJURY OCCURRED AND THE FALL WILL BE CLEAN ED UP.","sourceDate":"2003-06-16"},{"SOURCE_ROW_NUMBER":"33450","DOCUMENT_NO":"220031140009","ACCIDENT_DT":"04/07/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROCK FALL OCCURRED MEASURING 35' X 20' X 10' HIGH AT THE NO.3 INTERSECTION LAST OPEN CROSSCUT. NO EQUIPMENT WAS INVOLVED, NO VENTILATION WAS DISTURBED, NO INJURY OCCURRED, AND THE FALL WILL NOT BE CLEANED UP.","sourceDate":"2003-04-07"},{"SOURCE_ROW_NUMBER":"274236","DOCUMENT_NO":"220030130121","ACCIDENT_DT":"12/19/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Roof bolter helper, Rock bolter helper, Pinner helper","NO_INJURIES":"1","DAYS_LOST":"60","NARRATIVE":"WHILE UNLOADING BOLTS AND PLATES OUT OF A SCOOP BUCKET ONTO THE BOLTER, EMPLOYEE PICKED UP 5 TO 6 BOLTS TOOK ONE STEP BACK INTO A HOLE FORCING HIS LEFT KNEE BACKWARD. NOTE: OPERATIONS WERE IDL E FROM 12/21/02 THRU 1/2/03. REPORT IS WITHIN 10 DAY LIMIT.","sourceDate":"2002-12-19"},{"SOURCE_ROW_NUMBER":"231283","DOCUMENT_NO":"220022620006","ACCIDENT_DT":"09/12/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"OPERATOR WAS HAVING TROUBLE WITH THE STEEL STOPPING UP WHEN HE DROPPED THE HEAD THE STEEL STAYED IN THE HOLE. HE THEN RAISED THE HEAD BACK UP AND WHEN HE DID AS HE HIT THE ROTATION HE DID NOT REALIZE HIS GLOVE WAS CAUGHT BETWEEN THE PINNER HEAD & HIS STEEL CAUSING HIS RT ARM AND HAND TO TWIST AROUND STEEL.","sourceDate":"2002-09-12"},{"SOURCE_ROW_NUMBER":"110621","DOCUMENT_NO":"220022410036","ACCIDENT_DT":"08/22/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"WHILE DRILLING HOLE FOR ROOF BOLT THE DRILL STEEL FELL OUT OF THE TOP & HIT EE ON THE MIDDLE FINGER OF HIS LEFT HAND. CAUSING A LACERATION REQUIRING 4 SUTURES.","sourceDate":"2002-08-22"},{"SOURCE_ROW_NUMBER":"235639","DOCUMENT_NO":"220021570026","ACCIDENT_DT":"05/31/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL OCCURRED AT SPAD #3118 IN THE NO 3 ENTRY 1000' OUTBY SECTION MEASURING 20' X 20' X 8'. NO EQUIPMENT WAS INVOLVED. THE VENTILATION WAS NOT DISTURBED. NO INJURY OCCURRED. THE FALL WI LL NOT BE CLEANED UP.","sourceDate":"2002-05-31"},{"SOURCE_ROW_NUMBER":"261528","DOCUMENT_NO":"220021220036","ACCIDENT_DT":"04/26/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL WAS DISCOVERED IN THE NO 2 & 1 ENTRY AT SPAD 1640 MEASURING 80'X 18'X 6'. NO EQUIPMENT WAS INVOLVED. THE VENTILATION WAS NOT DISTURBED. NO INJURY OCCURRED. THE FALL WILL NOT BE CLE ANED UP.","sourceDate":"2002-04-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-05-20","lastDate":"2005-05-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":182,"firstDate":"2000-01-28","lastDate":"2004-08-16","metrics":{"ss":64,"delinquent":166,"recentRows":0,"paidPenalty":17675,"proposedPenalty":17675,"currentAssessment":17675},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"919334","VIOLATION_NO":"7335838","ISSUE_DT":"08/16/2004","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-16"},{"SOURCE_ROW_NUMBER":"919249","VIOLATION_NO":"7330683","ISSUE_DT":"04/23/2004","CFR_STANDARD_CD":"75.1100-2(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-23"},{"SOURCE_ROW_NUMBER":"919248","VIOLATION_NO":"7330682","ISSUE_DT":"04/23/2004","CFR_STANDARD_CD":"75.208","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"286.00","CURRENT_ASSESSMENT_AMT":"286.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-23"},{"SOURCE_ROW_NUMBER":"919247","VIOLATION_NO":"7330679","ISSUE_DT":"04/22/2004","CFR_STANDARD_CD":"75.208","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"919246","VIOLATION_NO":"7330672","ISSUE_DT":"04/16/2004","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"919245","VIOLATION_NO":"7330671","ISSUE_DT":"04/16/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"919244","VIOLATION_NO":"7330670","ISSUE_DT":"04/16/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"919243","VIOLATION_NO":"7330669","ISSUE_DT":"04/16/2004","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"286.00","CURRENT_ASSESSMENT_AMT":"286.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"919242","VIOLATION_NO":"7330668","ISSUE_DT":"04/16/2004","CFR_STANDARD_CD":"75.606","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"286.00","CURRENT_ASSESSMENT_AMT":"286.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"922279","VIOLATION_NO":"3788200","ISSUE_DT":"03/31/2004","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"268.00","CURRENT_ASSESSMENT_AMT":"268.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-31"},{"SOURCE_ROW_NUMBER":"880694","VIOLATION_NO":"7332375","ISSUE_DT":"02/23/2004","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"918874","VIOLATION_NO":"7334346","ISSUE_DT":"02/11/2004","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"217.00","CURRENT_ASSESSMENT_AMT":"217.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":469,"firstDate":"2000-01-05","lastDate":"2004-04-21","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":10,"validSamples":459,"maxConcentration":4.684,"concentrationTotal":215.21},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"239474","CASS_NUM":"50740007","SMP_TAKEN_DT":"4/21/2004","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"1290173","CASS_NUM":"57529379","SMP_TAKEN_DT":"4/6/2004","CONC":".963","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"1131002","CASS_NUM":"57529419","SMP_TAKEN_DT":"4/6/2004","CONC":".243","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"978621","CASS_NUM":"57529356","SMP_TAKEN_DT":"4/6/2004","CONC":"1.022","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"808682","CASS_NUM":"57529721","SMP_TAKEN_DT":"4/6/2004","CONC":".963","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"655108","CASS_NUM":"57529364","SMP_TAKEN_DT":"4/6/2004","CONC":".25","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"126049","CASS_NUM":"57529333","SMP_TAKEN_DT":"4/6/2004","CONC":".381","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"1231918","CASS_NUM":"57529700","SMP_TAKEN_DT":"3/24/2004","CONC":".14","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-24"},{"SOURCE_ROW_NUMBER":"1575592","CASS_NUM":"50739773","SMP_TAKEN_DT":"3/18/2004","CONC":".149","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-18"},{"SOURCE_ROW_NUMBER":"1308325","CASS_NUM":"50739784","SMP_TAKEN_DT":"3/18/2004","CONC":".593","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-18"},{"SOURCE_ROW_NUMBER":"1212872","CASS_NUM":"50739733","SMP_TAKEN_DT":"3/18/2004","CONC":".702","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-18"},{"SOURCE_ROW_NUMBER":"625759","CASS_NUM":"50739763","SMP_TAKEN_DT":"3/18/2004","CONC":".066","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-18"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":10,"firstDate":"2003-03-05","lastDate":"2004-08-31","metrics":{"linkedIssuances":10},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":45,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1995-09-01","lastDate":"2003-02-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":98,"firstDate":"2000-01-04","lastDate":"2004-10-28","metrics":{"inspectors":122,"recentRows":0,"onSiteHours":1581,"inspectionHours":2493.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"176159","EVENT_NO":"4154949","INSPECTION_BEGIN_DT":"10/28/2004","INSPECTION_END_DT":"11/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2004-10-28"},{"SOURCE_ROW_NUMBER":"509885","EVENT_NO":"4154938","INSPECTION_BEGIN_DT":"07/06/2004","INSPECTION_END_DT":"09/08/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2004-07-06"},{"SOURCE_ROW_NUMBER":"344707","EVENT_NO":"4154934","INSPECTION_BEGIN_DT":"06/18/2004","INSPECTION_END_DT":"06/18/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2004-06-18"},{"SOURCE_ROW_NUMBER":"409392","EVENT_NO":"4127319","INSPECTION_BEGIN_DT":"06/15/2004","INSPECTION_END_DT":"06/16/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2004-06-15"},{"SOURCE_ROW_NUMBER":"56992","EVENT_NO":"4155960","INSPECTION_BEGIN_DT":"04/05/2004","INSPECTION_END_DT":"04/22/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-04-05"},{"SOURCE_ROW_NUMBER":"590363","EVENT_NO":"4154921","INSPECTION_BEGIN_DT":"04/01/2004","INSPECTION_END_DT":"05/17/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"55.5","SUM_TOTAL_ON_SITE_HOURS":"40.5","sourceDate":"2004-04-01"},{"SOURCE_ROW_NUMBER":"535065","EVENT_NO":"4155957","INSPECTION_BEGIN_DT":"03/30/2004","INSPECTION_END_DT":"04/12/2004","ACTIVITY_CODE":"CED","ACTIVITY":"RESP DUST TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2004-03-30"},{"SOURCE_ROW_NUMBER":"35333","EVENT_NO":"4155951","INSPECTION_BEGIN_DT":"03/16/2004","INSPECTION_END_DT":"03/31/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-03-16"},{"SOURCE_ROW_NUMBER":"413617","EVENT_NO":"4127279","INSPECTION_BEGIN_DT":"02/23/2004","INSPECTION_END_DT":"03/01/2004","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"984987","EVENT_NO":"4155938","INSPECTION_BEGIN_DT":"02/11/2004","INSPECTION_END_DT":"02/26/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2004-02-11"},{"SOURCE_ROW_NUMBER":"983621","EVENT_NO":"4154805","INSPECTION_BEGIN_DT":"01/13/2004","INSPECTION_END_DT":"03/05/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"99","SUM_TOTAL_ON_SITE_HOURS":"68.5","sourceDate":"2004-01-13"},{"SOURCE_ROW_NUMBER":"313317","EVENT_NO":"4155930","INSPECTION_BEGIN_DT":"01/13/2004","INSPECTION_END_DT":"01/22/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2004-01-13"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":43,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q2":{"hours":9056,"employees":39,"production":9129},"2004-Q1":{"hours":20411,"employees":36,"production":47387},"2003-Q4":{"hours":19567,"employees":36,"production":66667},"2003-Q3":{"hours":24875,"employees":49,"production":88655},"2003-Q2":{"hours":28080,"employees":47,"production":100115},"2003-Q1":{"hours":27828,"employees":47,"production":110502},"2002-Q4":{"hours":28705,"employees":54,"production":100879},"2002-Q3":{"hours":37668,"employees":55,"production":97908},"2002-Q2":{"hours":31416,"employees":56,"production":108281},"2002-Q1":{"hours":28520,"employees":54,"production":106564},"2001-Q4":{"hours":29884,"employees":51,"production":101566},"2001-Q3":{"hours":28960,"employees":51,"production":97248}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":127647,"employees":53,"production":323972},"2001":{"hours":114832,"employees":51,"production":393848},"2002":{"hours":126309,"employees":55,"production":413632},"2003":{"hours":100350,"employees":45,"production":365939},"2004":{"hours":29467,"employees":38,"production":56516}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2001-07-30","lastDate":"2003-09-11","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1138,"pelDoseTotal":796},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"201738","EVENT_NO":"4155377","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"075","ACT_DOSE_85":"6","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"201737","EVENT_NO":"4155377","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"39","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"201736","EVENT_NO":"4155377","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"52","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"201735","EVENT_NO":"4155377","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"103","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"201734","EVENT_NO":"4155377","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"98","PEL_DOSE_90":"82","SURVEY_TYPE":"I","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"201733","EVENT_NO":"4137589","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"62","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"201732","EVENT_NO":"4137589","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"75","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"201731","EVENT_NO":"4137589","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"53","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"201730","EVENT_NO":"4137589","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"133","PEL_DOSE_90":"113","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"201729","EVENT_NO":"4137589","SURVEY_DATE":"05/21/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"144","PEL_DOSE_90":"132","SURVEY_TYPE":"I","sourceDate":"2002-05-21"},{"SOURCE_ROW_NUMBER":"201728","EVENT_NO":"4137541","SURVEY_DATE":"07/30/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"68","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"201727","EVENT_NO":"4137541","SURVEY_DATE":"07/30/2001","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"58","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2001-07-30"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":58,"firstDate":"2000-01-05","lastDate":"2004-04-21","metrics":{"recentRows":0,"voidSamples":5,"maxQuartzPct":19.2,"validSamples":53,"quartzPctTotal":456.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"163127","CASSETTE_NO":"50740007","SAMPLE_DT":"04/21/2004","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2004-04-21"},{"SOURCE_ROW_NUMBER":"161685","CASSETTE_NO":"57529379","SAMPLE_DT":"04/06/2004","QUARTZ_PCT":"08.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"71019","CASSETTE_NO":"57529721","SAMPLE_DT":"04/06/2004","QUARTZ_PCT":"09.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"32058","CASSETTE_NO":"57529356","SAMPLE_DT":"04/06/2004","QUARTZ_PCT":"09.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-04-06"},{"SOURCE_ROW_NUMBER":"27597","CASSETTE_NO":"50739722","SAMPLE_DT":"03/30/2004","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2004-03-30"},{"SOURCE_ROW_NUMBER":"140604","CASSETTE_NO":"57530822","SAMPLE_DT":"02/19/2004","QUARTZ_PCT":"08.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"112729","CASSETTE_NO":"57530780","SAMPLE_DT":"02/19/2004","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"61442","CASSETTE_NO":"57530649","SAMPLE_DT":"02/19/2004","QUARTZ_PCT":"14.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"86577","CASSETTE_NO":"57530536","SAMPLE_DT":"01/14/2004","QUARTZ_PCT":"14.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-14"},{"SOURCE_ROW_NUMBER":"40842","CASSETTE_NO":"57530508","SAMPLE_DT":"01/14/2004","QUARTZ_PCT":"13.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-14"},{"SOURCE_ROW_NUMBER":"67286","CASSETTE_NO":"50688778","SAMPLE_DT":"01/05/2004","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2004-01-05"},{"SOURCE_ROW_NUMBER":"65961","CASSETTE_NO":"50688770","SAMPLE_DT":"01/05/2004","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2004-01-05"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":183,"firstDate":"2000-01-28","lastDate":"2004-08-16","metrics":{"ss":64,"amountDue":17675,"contested":0,"amountPaid":17675,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":17675},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2366671","VIOLATION_NO":"7335838","VIOLATION_ISSUE_DT":"08/16/2004","SIG_SUB":"N","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-08-16"},{"SOURCE_ROW_NUMBER":"2366610","VIOLATION_NO":"7330683","VIOLATION_ISSUE_DT":"04/23/2004","SIG_SUB":"N","PART_SECTION":"75.1100-2(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/27/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-23"},{"SOURCE_ROW_NUMBER":"2366609","VIOLATION_NO":"7330682","VIOLATION_ISSUE_DT":"04/23/2004","SIG_SUB":"Y","PART_SECTION":"75.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/23/2004","PROPOSED_PENALTY":"286","AMOUNT_DUE":"286","AMOUNT_PAID":"286","CONTESTED_IND":"N","sourceDate":"2004-04-23"},{"SOURCE_ROW_NUMBER":"2366608","VIOLATION_NO":"7330679","VIOLATION_ISSUE_DT":"04/22/2004","SIG_SUB":"N","PART_SECTION":"75.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-22"},{"SOURCE_ROW_NUMBER":"2366607","VIOLATION_NO":"7330672","VIOLATION_ISSUE_DT":"04/16/2004","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/16/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"2366606","VIOLATION_NO":"7330671","VIOLATION_ISSUE_DT":"04/16/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/22/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"2366605","VIOLATION_NO":"7330670","VIOLATION_ISSUE_DT":"04/16/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/16/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"2366604","VIOLATION_NO":"7330669","VIOLATION_ISSUE_DT":"04/16/2004","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/16/2004","PROPOSED_PENALTY":"286","AMOUNT_DUE":"286","AMOUNT_PAID":"286","CONTESTED_IND":"N","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"2366603","VIOLATION_NO":"7330668","VIOLATION_ISSUE_DT":"04/16/2004","SIG_SUB":"Y","PART_SECTION":"75.606","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/16/2004","PROPOSED_PENALTY":"286","AMOUNT_DUE":"286","AMOUNT_PAID":"286","CONTESTED_IND":"N","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"2366602","VIOLATION_NO":"3788200","VIOLATION_ISSUE_DT":"03/31/2004","SIG_SUB":"Y","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/31/2004","PROPOSED_PENALTY":"268","AMOUNT_DUE":"268","AMOUNT_PAID":"268","CONTESTED_IND":"N","sourceDate":"2004-03-31"},{"SOURCE_ROW_NUMBER":"2366595","VIOLATION_NO":"7332375","VIOLATION_ISSUE_DT":"02/23/2004","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/25/2004","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"2366580","VIOLATION_NO":"7334346","VIOLATION_ISSUE_DT":"02/11/2004","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/18/2004","PROPOSED_PENALTY":"217","AMOUNT_DUE":"217","AMOUNT_PAID":"217","CONTESTED_IND":"N","sourceDate":"2004-02-11"}]}],"safety":{"href":"/api/v1/mines/4406807/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406807/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.208","part":"75","subchapter":"O","subpart":"C","id":"75.208","citation":"30 CFR 75.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.606","heading":"Protection of trailing cables.","id":"75.606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.606","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nTrailing cables shall be adequately protected to prevent damage by mobile equipment.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406807","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}