{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4406759","name":"DC-36","status":"Abandoned and Sealed","status_date":"2023-08-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Buchanan","nearest_town":"JEWELL RIDGE","operator_id":"0164793","operator_name":"Sons Energy, LLC.","controller_id":"0149121","controller_name":"Danny K Justice; Lori A Brinager; Cecil T Brinager","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.258889,"longitude":-81.855},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":13899},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406759","name":"DC-36"},"operator":{"type":"operator","id":"0164793","name":"Sons Energy, LLC."},"controller":{"type":"controller","id":"0149121","name":"Danny K Justice; Lori A Brinager; Cecil T Brinager"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"mine","id":"4406759","name":"DC-36"},"validFrom":"1979-10-29","validTo":"2012-01-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|C01767|1979-10-29|2012-01-16"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P10904","name":"Dominion Coal Corporation"},"object":{"type":"mine","id":"4406759","name":"DC-36"},"validFrom":"1994-04-01","validTo":"2015-09-28","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|P10904|1994-04-01|2015-09-28"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01767","name":"Sunoco, Inc."},"object":{"type":"operator","id":"P10904","name":"Dominion Coal Corporation"},"validFrom":"1994-04-01","validTo":"2012-01-16","current":false,"derived":true,"evidenceMineId":"4406759","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|P10904|1994-04-01|C01767|1979-10-29|55920"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0104093","name":"SunCoke Energy Incorporated"},"object":{"type":"mine","id":"4406759","name":"DC-36"},"validFrom":"2012-01-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0104093|2012-01-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0104093","name":"SunCoke Energy Incorporated"},"object":{"type":"operator","id":"P10904","name":"Dominion Coal Corporation"},"validFrom":"2012-01-17","validTo":"2015-09-28","current":false,"derived":true,"evidenceMineId":"4406759","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|P10904|1994-04-01|0104093|2012-01-17|18070"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0098493","name":"Steven T  Ratliff et al"},"object":{"type":"mine","id":"4406759","name":"DC-36"},"validFrom":"2015-07-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0098493|2015-07-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0139633","name":"Maverick Coal Inc."},"object":{"type":"mine","id":"4406759","name":"DC-36"},"validFrom":"2015-09-29","validTo":"2019-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0139633|2015-09-29|2019-06-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0098493","name":"Steven T  Ratliff et al"},"object":{"type":"operator","id":"0139633","name":"Maverick Coal Inc."},"validFrom":"2015-09-29","validTo":"2019-06-30","current":false,"derived":true,"evidenceMineId":"4406759","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0139633|2015-09-29|0098493|2015-07-10|16216"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0098493","name":"Noah L  Vandyke et al"},"object":{"type":"operator","id":"0139633","name":"Maverick Coal Inc."},"validFrom":"2015-09-29","validTo":"2019-06-30","current":false,"derived":true,"evidenceMineId":"4406759","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0139633|2015-09-29|0098493|2015-07-10|16217"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0164793","name":"Sons Energy, LLC."},"object":{"type":"mine","id":"4406759","name":"DC-36"},"validFrom":"2019-07-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0164793|2019-07-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0149121","name":"Danny K Justice et al"},"object":{"type":"mine","id":"4406759","name":"DC-36"},"validFrom":"2019-07-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0149121|2019-07-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0149121","name":"Danny K Justice et al"},"object":{"type":"operator","id":"0164793","name":"Sons Energy, LLC."},"validFrom":"2019-07-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406759","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0164793|2019-07-01|0149121|2019-07-01|30500"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0149121","name":"Cecil T Brinager et al"},"object":{"type":"operator","id":"0164793","name":"Sons Energy, LLC."},"validFrom":"2019-07-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406759","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0164793|2019-07-01|0149121|2019-07-01|30501"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0149121","name":"Lori A Brinager et al"},"object":{"type":"operator","id":"0164793","name":"Sons Energy, LLC."},"validFrom":"2019-07-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406759","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406759|0164793|2019-07-01|0149121|2019-07-01|30502"}}],"coverage":{"historyRecords":7,"edgeCount":14,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":90,"firstDate":"2000-01-11","lastDate":"2015-05-22","metrics":{"daysLost":1797,"injuries":62,"fatalities":0,"recentRows":0,"restrictedDays":551,"contractorRecords":10},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"97754","DOCUMENT_NO":"220151550005","ACCIDENT_DT":"05/22/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee pulled hard to open a track switch, switch opened easy causing him to pull a muscle in his left rib.","sourceDate":"2015-05-22"},{"SOURCE_ROW_NUMBER":"80704","DOCUMENT_NO":"220143250024","ACCIDENT_DT":"11/12/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"In the process of building a brattice; the ee was placing a block when another ee tossed him another block-catching the injured ee's finger between the blocks, resulting in a fracture to the tip of the finger. There was no medical attention administered, only diagnostic and first aid.","sourceDate":"2014-11-12"},{"SOURCE_ROW_NUMBER":"46324","DOCUMENT_NO":"220142310025","ACCIDENT_DT":"08/07/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"The ee was injured while spot bolting one-break outby the #6 heading. The bolt rotated when the ee attempted to place the bolt into the drilled hole. His little finger was caught between the bolt and drill chuck resulting in a laceration and fracture to the finger.","sourceDate":"2014-08-07"},{"SOURCE_ROW_NUMBER":"231279","DOCUMENT_NO":"220141570012","ACCIDENT_DT":"05/28/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"The ee was injured as a result of a man bus derailment. In an attempt to re-rail the man bus a ratchet type jack was placed under one corner of the man bus and two crib blocks were placed under the center to rest the frame. The jack handle suddenly released upward striking the ee on the left side of the face resulting in a temporal fracture.","sourceDate":"2014-05-28"},{"SOURCE_ROW_NUMBER":"235630","DOCUMENT_NO":"220140800012","ACCIDENT_DT":"03/17/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The ee was installing a roof bolt and lifted his left hand to hold the plate in position.  His left middle finger was caught between the plate and mine roof.  The ee received a laceration to the finger requiring several sutures.","sourceDate":"2014-03-17"},{"SOURCE_ROW_NUMBER":"252808","DOCUMENT_NO":"220140770050","ACCIDENT_DT":"03/13/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"The ee was struck in the face with a 4\" water line. The empty discharge line was struck by the shuttle car and in the turn hit the ee in the face. The ee was dazed but stated that he was ok and completed his shift. Later the ee went to the hospital and it was determined he had three fractures to his jaw.","sourceDate":"2014-03-13"},{"SOURCE_ROW_NUMBER":"179692","DOCUMENT_NO":"220140560027","ACCIDENT_DT":"02/18/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"343","NARRATIVE":"The ee was in the process of tramming miner and the machine became fouled. The ee de-energized the miner and was traveling on the right side of the machine when a piece of rock measuring 12\" X 11.5\" X 5' rolled out and pinned his right leg between the rock and mine floor resulting in two breaks to the tibia.","sourceDate":"2014-02-18"},{"SOURCE_ROW_NUMBER":"205448","DOCUMENT_NO":"220131700008","ACCIDENT_DT":"12/10/2012","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The employee has been diagnosed with Coal Worker's Pneumoconiosis(CWP) Dominion Coal was notified of this illness 12/10/2012. Employee is current off work for other medical. Dominion was notified by a medical doctor.","sourceDate":"2012-12-10"},{"SOURCE_ROW_NUMBER":"214094","DOCUMENT_NO":"220122980038","ACCIDENT_DT":"10/19/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall was discovered on U-section at Survey station 9755.  The fall area was approximately 6' in height, 20' in width and 20 plus feet in length. The fall area was mined in 10/1997 and was supported with point anchor bolt system. The fall area was dangered off to prevent access.","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"252807","DOCUMENT_NO":"220122980040","ACCIDENT_DT":"10/16/2012","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"31","NARRATIVE":"The ee had traveled by scoop to T-Section intake to retrieve conveyor belt to supply a belt move on another section of the mine.  The ee inserted a chain through the layers of belt that were on the mine floor & jumped across the belt to the opposite side. He felt a \"pop\" in his right knee resulting in pain & swelling to the knee.","sourceDate":"2012-10-16"},{"SOURCE_ROW_NUMBER":"119265","DOCUMENT_NO":"220122620039","ACCIDENT_DT":"09/05/2012","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"49","NARRATIVE":"A belt person uncoupled a 2\" waterline on the off-side of the #7 main line belt. He placed the 20' joint of water line across the belt to the track side to reconnect the line. The injured ee slid across the belt & as he stood up his feet slipped on the muddy mine floor resulting in the ee falling & striking his right hip on the track side belt rail resulting in a bruised muscle.","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"136524","DOCUMENT_NO":"220122270035","ACCIDENT_DT":"08/04/2012","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Motorman, Motor person, Swamper, Switchman, Locomotive operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The supply tram had derailed and the ee was in the process of rerailing the tram using a hydraulic jack to lift the arm. A pin in the jack bar bracket inadvertently came out of the jack resulting in injury to the ee's ring finger on his right hand/being caught between the jack bar and the equipment. The ee received 3 sutures to close the laceration.","sourceDate":"2012-08-04"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2023-08-16","lastDate":"2023-08-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3576,"firstDate":"2000-01-18","lastDate":"2016-10-07","metrics":{"ss":1085,"delinquent":3513,"recentRows":0,"paidPenalty":2234446.2,"proposedPenalty":2892722,"currentAssessment":2234446.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1397551","VIOLATION_NO":"9093553","ISSUE_DT":"10/07/2016","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-10-07"},{"SOURCE_ROW_NUMBER":"1397550","VIOLATION_NO":"9093552","ISSUE_DT":"10/06/2016","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-10-06"},{"SOURCE_ROW_NUMBER":"1397549","VIOLATION_NO":"9093551","ISSUE_DT":"10/06/2016","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-10-06"},{"SOURCE_ROW_NUMBER":"1377037","VIOLATION_NO":"8214739","ISSUE_DT":"07/30/2015","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-30"},{"SOURCE_ROW_NUMBER":"1377036","VIOLATION_NO":"8214738","ISSUE_DT":"07/30/2015","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-30"},{"SOURCE_ROW_NUMBER":"1377046","VIOLATION_NO":"9092091","ISSUE_DT":"07/27/2015","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"1377045","VIOLATION_NO":"9092090","ISSUE_DT":"07/27/2015","CFR_STANDARD_CD":"75.1100-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"1377044","VIOLATION_NO":"9092089","ISSUE_DT":"07/27/2015","CFR_STANDARD_CD":"75.903","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2901.00","CURRENT_ASSESSMENT_AMT":"2901.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"1377043","VIOLATION_NO":"9092088","ISSUE_DT":"07/27/2015","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"897.00","CURRENT_ASSESSMENT_AMT":"897.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"1377047","VIOLATION_NO":"9092087","ISSUE_DT":"07/16/2015","CFR_STANDARD_CD":"75.364(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-16"},{"SOURCE_ROW_NUMBER":"1377035","VIOLATION_NO":"8214730","ISSUE_DT":"07/09/2015","CFR_STANDARD_CD":"75.518","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-09"},{"SOURCE_ROW_NUMBER":"1377034","VIOLATION_NO":"8214729","ISSUE_DT":"07/09/2015","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-09"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":659,"firstDate":"2000-08-21","lastDate":"2016-06-02","metrics":{"appeals":0,"decisions":659,"recentRows":0,"decisionPenalty":1374732.2,"originalPenalty":2248684},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"375674","VIOLATION_NO":"9091824","DOCKET_NO":"VA 2015-0288","DECISION_DT":"06/02/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9634.00","DECISION_PENALTY_AMT":"6744.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2016-06-02"},{"SOURCE_ROW_NUMBER":"376595","VIOLATION_NO":"9091829","DOCKET_NO":"VA 2015-0294","DECISION_DT":"12/24/2015","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"2106.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-12-24"},{"SOURCE_ROW_NUMBER":"116910","VIOLATION_NO":"9091831","DOCKET_NO":"VA 2015-0294","DECISION_DT":"12/24/2015","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"5961.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-12-24"},{"SOURCE_ROW_NUMBER":"370178","VIOLATION_NO":"8215107","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1450.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"370177","VIOLATION_NO":"8212617","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1450.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"370176","VIOLATION_NO":"8211543","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"800.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"369691","VIOLATION_NO":"8211544","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1500.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"369610","VIOLATION_NO":"9870686","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1700.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"369406","VIOLATION_NO":"8211538","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1450.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"369207","VIOLATION_NO":"8211537","DOCKET_NO":"VA 2015-0084","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4329.00","DECISION_PENALTY_AMT":"1944.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"113455","VIOLATION_NO":"8211539","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1412.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"},{"SOURCE_ROW_NUMBER":"112868","VIOLATION_NO":"8211535","DOCKET_NO":"VA 2015-0084","DECISION_DT":"09/25/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"750.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2015-09-25"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":3611,"firstDate":"2000-01-04","lastDate":"2014-12-11","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":752,"validSamples":2859,"maxConcentration":10.612,"concentrationTotal":2299.527},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1662545","CASS_NUM":"58175858","SMP_TAKEN_DT":"12/11/2014","CONC":".45","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"1662544","CASS_NUM":"58175546","SMP_TAKEN_DT":"12/11/2014","CONC":".692","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"1657777","CASS_NUM":"58175547","SMP_TAKEN_DT":"12/11/2014","CONC":".337","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"1526202","CASS_NUM":"58175860","SMP_TAKEN_DT":"12/11/2014","CONC":".318","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"1228024","CASS_NUM":"58175588","SMP_TAKEN_DT":"12/11/2014","CONC":".528","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"345110","CASS_NUM":"58175811","SMP_TAKEN_DT":"12/11/2014","CONC":".087","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"71704","CASS_NUM":"58175502","SMP_TAKEN_DT":"12/11/2014","CONC":".489","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"1175583","CASS_NUM":"51321119","SMP_TAKEN_DT":"12/5/2014","CONC":".123","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"1130370","CASS_NUM":"58175800","SMP_TAKEN_DT":"12/5/2014","CONC":".501","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"1108507","CASS_NUM":"58175808","SMP_TAKEN_DT":"12/5/2014","CONC":"1.079","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"1021725","CASS_NUM":"58175773","SMP_TAKEN_DT":"12/5/2014","CONC":".83","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"725771","CASS_NUM":"58175820","SMP_TAKEN_DT":"12/5/2014","CONC":".136","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-05"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":103,"firstDate":"2000-03-28","lastDate":"2014-12-22","metrics":{"linkedIssuances":103},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":658,"firstDate":"2007-04-05","lastDate":"2015-06-08","metrics":{"decisions":658,"ssChanged":117,"recentRows":0,"decisionPenalty":1374497.2,"proposedPenalty":2255256},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"153706","CITATION_NO":"9091829","CITATION_ISSUE_DT":"06/08/2015","DOCKET_NO":"VA 2015-0294","DECISION_DT":"12/24/2015","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"2106.00","sourceDate":"2015-06-08"},{"SOURCE_ROW_NUMBER":"36720","CITATION_NO":"9091831","CITATION_ISSUE_DT":"06/08/2015","DOCKET_NO":"VA 2015-0294","DECISION_DT":"12/24/2015","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5961.00","DECISION_PENALTY_AMT":"5961.00","sourceDate":"2015-06-08"},{"SOURCE_ROW_NUMBER":"154655","CITATION_NO":"9091824","CITATION_ISSUE_DT":"05/12/2015","DOCKET_NO":"VA 2015-0288","DECISION_DT":"06/02/2016","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"9634.00","DECISION_PENALTY_AMT":"6744.00","sourceDate":"2015-05-12"},{"SOURCE_ROW_NUMBER":"262460","CITATION_NO":"9091773","CITATION_ISSUE_DT":"03/02/2015","DOCKET_NO":"VA 2015-0198","DECISION_DT":"09/24/2015","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"4000.00","sourceDate":"2015-03-02"},{"SOURCE_ROW_NUMBER":"375177","CITATION_NO":"8215107","CITATION_ISSUE_DT":"12/05/2014","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1450.00","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"265774","CITATION_NO":"9870686","CITATION_ISSUE_DT":"12/02/2014","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"70.100(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2473.00","DECISION_PENALTY_AMT":"1700.00","sourceDate":"2014-12-02"},{"SOURCE_ROW_NUMBER":"265901","CITATION_NO":"8212617","CITATION_ISSUE_DT":"11/28/2014","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1450.00","sourceDate":"2014-11-28"},{"SOURCE_ROW_NUMBER":"152502","CITATION_NO":"8211544","CITATION_ISSUE_DT":"11/20/2014","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1500.00","sourceDate":"2014-11-20"},{"SOURCE_ROW_NUMBER":"38336","CITATION_NO":"8211543","CITATION_ISSUE_DT":"11/20/2014","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"800.00","sourceDate":"2014-11-20"},{"SOURCE_ROW_NUMBER":"321083","CITATION_NO":"8211539","CITATION_ISSUE_DT":"11/13/2014","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1412.00","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"264236","CITATION_NO":"8211538","CITATION_ISSUE_DT":"11/13/2014","DOCKET_NO":"VA 2015-0116","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1450.00","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"94787","CITATION_NO":"8211537","CITATION_ISSUE_DT":"11/06/2014","DOCKET_NO":"VA 2015-0084","DECISION_DT":"09/25/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"4329.00","DECISION_PENALTY_AMT":"1944.00","sourceDate":"2014-11-06"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":298,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":76,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":7,"firstDate":"1994-04-01","lastDate":"2019-07-01","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":544,"firstDate":"2000-01-05","lastDate":"2020-01-31","metrics":{"inspectors":881,"recentRows":0,"onSiteHours":18974.25,"inspectionHours":28137.25,"inspectionSamples":2286},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"559109","EVENT_NO":"4419145","INSPECTION_BEGIN_DT":"01/31/2020","INSPECTION_END_DT":"01/31/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2020-01-31"},{"SOURCE_ROW_NUMBER":"1141273","EVENT_NO":"4421769","INSPECTION_BEGIN_DT":"07/03/2019","INSPECTION_END_DT":"07/03/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2019-07-03"},{"SOURCE_ROW_NUMBER":"1152668","EVENT_NO":"4419537","INSPECTION_BEGIN_DT":"10/06/2016","INSPECTION_END_DT":"10/11/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.75","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2016-10-06"},{"SOURCE_ROW_NUMBER":"629344","EVENT_NO":"4404360","INSPECTION_BEGIN_DT":"06/28/2016","INSPECTION_END_DT":"06/28/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2016-06-28"},{"SOURCE_ROW_NUMBER":"791834","EVENT_NO":"4418761","INSPECTION_BEGIN_DT":"01/28/2016","INSPECTION_END_DT":"01/28/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2016-01-28"},{"SOURCE_ROW_NUMBER":"103413","EVENT_NO":"4416433","INSPECTION_BEGIN_DT":"01/05/2016","INSPECTION_END_DT":"01/06/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2016-01-05"},{"SOURCE_ROW_NUMBER":"70238","EVENT_NO":"4416653","INSPECTION_BEGIN_DT":"10/07/2015","INSPECTION_END_DT":"10/07/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2015-10-07"},{"SOURCE_ROW_NUMBER":"631482","EVENT_NO":"4418721","INSPECTION_BEGIN_DT":"07/29/2015","INSPECTION_END_DT":"07/29/2015","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2015-07-29"},{"SOURCE_ROW_NUMBER":"697704","EVENT_NO":"4412879","INSPECTION_BEGIN_DT":"07/16/2015","INSPECTION_END_DT":"07/20/2015","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2015-07-16"},{"SOURCE_ROW_NUMBER":"491221","EVENT_NO":"4412878","INSPECTION_BEGIN_DT":"07/02/2015","INSPECTION_END_DT":"09/24/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"120.5","SUM_TOTAL_ON_SITE_HOURS":"67.75","sourceDate":"2015-07-02"},{"SOURCE_ROW_NUMBER":"143010","EVENT_NO":"4412877","INSPECTION_BEGIN_DT":"06/29/2015","INSPECTION_END_DT":"06/29/2015","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2015-06-29"},{"SOURCE_ROW_NUMBER":"745029","EVENT_NO":"4404197","INSPECTION_BEGIN_DT":"06/24/2015","INSPECTION_END_DT":"06/24/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2015-06-24"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":130,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2016-Q3":{"hours":0,"employees":0,"production":0},"2016-Q1":{"hours":0,"employees":0,"production":0},"2015-Q3":{"hours":803,"employees":3,"production":0},"2015-Q2":{"hours":7061,"employees":10,"production":0},"2015-Q1":{"hours":5856,"employees":45,"production":0},"2014-Q4":{"hours":51881,"employees":99,"production":46744},"2014-Q3":{"hours":57058,"employees":99,"production":67538},"2014-Q2":{"hours":55562,"employees":95,"production":49634},"2014-Q1":{"hours":59864,"employees":101,"production":55086},"2013-Q4":{"hours":5593,"employees":14,"production":0},"2013-Q3":{"hours":10341,"employees":18,"production":0},"2013-Q2":{"hours":6768,"employees":12,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":31,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":131704,"employees":51,"production":344665},"2007":{"hours":141440,"employees":56,"production":366118},"2008":{"hours":176554,"employees":68,"production":326223},"2009":{"hours":182659,"employees":74,"production":249675},"2010":{"hours":243048,"employees":86,"production":203370},"2011":{"hours":267433,"employees":87,"production":160995},"2012":{"hours":306423,"employees":114,"production":219077},"2013":{"hours":53267,"employees":36,"production":23109},"2014":{"hours":224365,"employees":99,"production":219002},"2015":{"hours":13720,"employees":19,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":200,"firstDate":"2000-03-15","lastDate":"2014-06-17","metrics":{"recentRows":0,"doseOver100":41,"actDoseTotal":15606,"pelDoseTotal":11428},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"201159","EVENT_NO":"4416227","SURVEY_DATE":"06/17/2014","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"58","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"201158","EVENT_NO":"4416227","SURVEY_DATE":"06/17/2014","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"115","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"201157","EVENT_NO":"4416227","SURVEY_DATE":"06/17/2014","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"93","PEL_DOSE_90":"69","SURVEY_TYPE":"I","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"201156","EVENT_NO":"4416227","SURVEY_DATE":"06/17/2014","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"39","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"201155","EVENT_NO":"4416227","SURVEY_DATE":"06/17/2014","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"22","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"201154","EVENT_NO":"4416227","SURVEY_DATE":"06/17/2014","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"68","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"201153","EVENT_NO":"4416227","SURVEY_DATE":"06/17/2014","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"57","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2014-06-17"},{"SOURCE_ROW_NUMBER":"201166","EVENT_NO":"4416228","SURVEY_DATE":"03/12/2014","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"115","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"201165","EVENT_NO":"4416228","SURVEY_DATE":"03/12/2014","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"37","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"201164","EVENT_NO":"4416228","SURVEY_DATE":"03/12/2014","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"89","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"201163","EVENT_NO":"4416228","SURVEY_DATE":"03/12/2014","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"43","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"201162","EVENT_NO":"4416228","SURVEY_DATE":"03/12/2014","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"80","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2014-03-12"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":292,"firstDate":"2000-01-05","lastDate":"2014-12-11","metrics":{"recentRows":0,"voidSamples":16,"maxQuartzPct":19.4,"validSamples":276,"quartzPctTotal":1506.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"164708","CASSETTE_NO":"58175546","SAMPLE_DT":"12/11/2014","QUARTZ_PCT":"07.5","QUARTZ_MICROGRAMS":"51","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"68847","CASSETTE_NO":"58175547","SAMPLE_DT":"12/11/2014","QUARTZ_PCT":"06.8","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-12-11"},{"SOURCE_ROW_NUMBER":"157687","CASSETTE_NO":"58175820","SAMPLE_DT":"12/05/2014","QUARTZ_PCT":"05.1","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"59891","CASSETTE_NO":"58175768","SAMPLE_DT":"12/05/2014","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"148002","CASSETTE_NO":"58163110","SAMPLE_DT":"09/05/2014","QUARTZ_PCT":"03.9","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-09-05"},{"SOURCE_ROW_NUMBER":"40935","CASSETTE_NO":"58163105","SAMPLE_DT":"09/05/2014","QUARTZ_PCT":"06.3","QUARTZ_MICROGRAMS":"26","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-09-05"},{"SOURCE_ROW_NUMBER":"85803","CASSETTE_NO":"58174129","SAMPLE_DT":"08/13/2014","QUARTZ_PCT":"05.2","QUARTZ_MICROGRAMS":"30","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-08-13"},{"SOURCE_ROW_NUMBER":"65073","CASSETTE_NO":"58173988","SAMPLE_DT":"08/13/2014","QUARTZ_PCT":"07.0","QUARTZ_MICROGRAMS":"30","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-08-13"},{"SOURCE_ROW_NUMBER":"117606","CASSETTE_NO":"57959104","SAMPLE_DT":"03/12/2014","QUARTZ_PCT":"07.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"139975","CASSETTE_NO":"57995492","SAMPLE_DT":"01/23/2013","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-01-23"},{"SOURCE_ROW_NUMBER":"101896","CASSETTE_NO":"57995263","SAMPLE_DT":"12/18/2012","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-12-18"},{"SOURCE_ROW_NUMBER":"21663","CASSETTE_NO":"51191303","SAMPLE_DT":"11/16/2012","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2012-11-16"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3622,"firstDate":"2000-01-18","lastDate":"2016-10-07","metrics":{"ss":1085,"amountDue":2234446.2,"contested":127,"amountPaid":2234446.2,"recentRows":0,"section104d":8,"unterminated":6,"proposedPenalty":2892722},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2361215","VIOLATION_NO":"9093553","VIOLATION_ISSUE_DT":"10/07/2016","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2016","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2016-10-07"},{"SOURCE_ROW_NUMBER":"2361214","VIOLATION_NO":"9093552","VIOLATION_ISSUE_DT":"10/06/2016","SIG_SUB":"N","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/07/2016","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2016-10-06"},{"SOURCE_ROW_NUMBER":"2361213","VIOLATION_NO":"9093551","VIOLATION_ISSUE_DT":"10/06/2016","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/06/2016","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2016-10-06"},{"SOURCE_ROW_NUMBER":"2359709","VIOLATION_NO":"8214739","VIOLATION_ISSUE_DT":"07/30/2015","SIG_SUB":"Y","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/03/2015","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"190","CONTESTED_IND":"N","sourceDate":"2015-07-30"},{"SOURCE_ROW_NUMBER":"2359708","VIOLATION_NO":"8214738","VIOLATION_ISSUE_DT":"07/30/2015","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-07-30"},{"SOURCE_ROW_NUMBER":"2359718","VIOLATION_NO":"9092091","VIOLATION_ISSUE_DT":"07/27/2015","SIG_SUB":"N","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/29/2015","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"2359717","VIOLATION_NO":"9092090","VIOLATION_ISSUE_DT":"07/27/2015","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/29/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"2359716","VIOLATION_NO":"9092089","VIOLATION_ISSUE_DT":"07/27/2015","SIG_SUB":"Y","PART_SECTION":"75.903","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2015","PROPOSED_PENALTY":"2901","AMOUNT_DUE":"2901","AMOUNT_PAID":"2901","CONTESTED_IND":"N","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"2359715","VIOLATION_NO":"9092088","VIOLATION_ISSUE_DT":"07/27/2015","SIG_SUB":"N","SECTION_OF_ACT":"316(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/29/2015","PROPOSED_PENALTY":"897","AMOUNT_DUE":"897","AMOUNT_PAID":"897","CONTESTED_IND":"N","sourceDate":"2015-07-27"},{"SOURCE_ROW_NUMBER":"2360327","VIOLATION_NO":"9092087","VIOLATION_ISSUE_DT":"07/16/2015","SIG_SUB":"N","PART_SECTION":"75.364(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/16/2015","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2015-07-16"},{"SOURCE_ROW_NUMBER":"2359707","VIOLATION_NO":"8214730","VIOLATION_ISSUE_DT":"07/09/2015","SIG_SUB":"N","PART_SECTION":"75.518","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2015","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2015-07-09"},{"SOURCE_ROW_NUMBER":"2359706","VIOLATION_NO":"8214729","VIOLATION_ISSUE_DT":"07/09/2015","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/09/2015","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2015-07-09"}]}],"safety":{"href":"/api/v1/mines/4406759/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406759/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Disconnecting devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.903","part":"75","subchapter":"O","subpart":"J","id":"75.903","citation":"30 CFR 75.903","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment and circuits; overload and short circuit protection.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.518","part":"75","subchapter":"O","subpart":"F","id":"75.518","citation":"30 CFR 75.518","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406759","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}