{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4406195","name":"Mine No 3","status":"Abandoned and Sealed","status_date":"2011-01-28","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Buchanan","nearest_town":"Grundy","operator_id":"0052632","operator_name":"Cavalier Mineral Inc","controller_id":"C00283","controller_name":"Gary  Dotson","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.238888,"longitude":-82.125},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2695},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4406195","name":"Mine No 3"},"operator":{"type":"operator","id":"0052632","name":"Cavalier Mineral Inc"},"controller":{"type":"controller","id":"C00283","name":"Gary  Dotson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P16813","name":"Industrial Coal Corp"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"1985-03-01","validTo":"1987-06-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|P16813|1985-03-01|1987-06-17"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02682","name":"Ellis  Baldwin"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"1985-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|C02682|1985-03-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02682","name":"Ellis  Baldwin"},"object":{"type":"operator","id":"P16813","name":"Industrial Coal Corp"},"validFrom":"1985-03-01","validTo":"1987-06-17","current":false,"derived":true,"evidenceMineId":"4406195","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|P16813|1985-03-01|C02682|1985-03-01|60432"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P18939","name":"Classic Coal Corporation"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"1987-06-18","validTo":"2006-08-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|P18939|1987-06-18|2006-08-07"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C08919","name":"James Wayne  Estep"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"1987-06-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|C08919|1987-06-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C08919","name":"James Wayne  Estep"},"object":{"type":"operator","id":"P18939","name":"Classic Coal Corporation"},"validFrom":"1987-06-18","validTo":"2006-08-07","current":false,"derived":true,"evidenceMineId":"4406195","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|P18939|1987-06-18|C08919|1987-06-18|78437"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0040952","name":"Cullen  Ratliff"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"2002-07-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0040952|2002-07-11|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00283","name":"Gary  Dotson  et al"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"2004-05-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|C00283|2004-05-13|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0054051","name":"Kres B  VanDyke"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"2005-10-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0054051|2005-10-14|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0064584","name":"Vandyke Mining Inc."},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"2006-08-08","validTo":"2008-01-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0064584|2006-08-08|2008-01-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0054051","name":"Kres B  VanDyke"},"object":{"type":"operator","id":"0064584","name":"Vandyke Mining Inc."},"validFrom":"2006-08-08","validTo":"2008-01-29","current":false,"derived":true,"evidenceMineId":"4406195","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0064584|2006-08-08|0054051|2005-10-14|6928"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050601","name":"Abby Contractors Inc"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"2008-01-30","validTo":"2008-03-02","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0050601|2008-01-30|2008-03-02"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0040952","name":"Cullen  Ratliff"},"object":{"type":"operator","id":"0050601","name":"Abby Contractors Inc"},"validFrom":"2008-01-30","validTo":"2008-03-02","current":false,"derived":true,"evidenceMineId":"4406195","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0050601|2008-01-30|0040952|2002-07-11|1048"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0052632","name":"Cavalier Mineral Inc"},"object":{"type":"mine","id":"4406195","name":"Mine No 3"},"validFrom":"2008-03-03","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0052632|2008-03-03|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00283","name":"Gary  Dotson  et al"},"object":{"type":"operator","id":"0052632","name":"Cavalier Mineral Inc"},"validFrom":"2008-03-03","validTo":null,"current":true,"derived":true,"evidenceMineId":"4406195","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4406195|0052632|2008-03-03|C00283|2004-05-13|45731"}}],"coverage":{"historyRecords":5,"edgeCount":15,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":11,"firstDate":"2004-06-23","lastDate":"2009-10-16","metrics":{"daysLost":243,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":7,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"257098","DOCUMENT_NO":"220092990048","ACCIDENT_DT":"10/16/2009","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Lid covering pick breaker chain on feeder was raised up and braced so work could be done, when brace slipped letting lid fall suddenly hitting EE on finger of left hand.","sourceDate":"2009-10-16"},{"SOURCE_ROW_NUMBER":"265694","DOCUMENT_NO":"220092860078","ACCIDENT_DT":"09/30/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE said he was walking away from his 21SC. He then stopped on the corner, put his hand on the rib and rock rolled off the rib striking him on his right side. Witnesses from 3rd shift state that they pulled this rib prior to the beginning of the shift.","sourceDate":"2009-09-30"},{"SOURCE_ROW_NUMBER":"183967","DOCUMENT_NO":"220080140069","ACCIDENT_DT":"01/09/2008","DEGREE_INJURY":"INJURIES DUE TO NATURAL CAUSES","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Possible heart attack (illness). Employee has had two heart attacks before.","sourceDate":"2008-01-09"},{"SOURCE_ROW_NUMBER":"166753","DOCUMENT_NO":"220072980039","ACCIDENT_DT":"10/10/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"Shuttle car operator ran over a piece of bottom rock and ruptured himself. Had out patient surgery.","sourceDate":"2007-10-10"},{"SOURCE_ROW_NUMBER":"162436","DOCUMENT_NO":"220061740030","ACCIDENT_DT":"06/12/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Cutting a piece off plastic with a box cutter knife it slipped cut left hand.","sourceDate":"2006-06-12"},{"SOURCE_ROW_NUMBER":"145160","DOCUMENT_NO":"220052550034","ACCIDENT_DT":"08/31/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"78","NARRATIVE":"HE WAS RUNNING ROOF BOLTER HE TURNED AROUND TO GET A ROOF BOLT OFF RIB AND TWISTED HIS KNEE","sourceDate":"2005-08-31"},{"SOURCE_ROW_NUMBER":"76447","DOCUMENT_NO":"220052200042","ACCIDENT_DT":"07/28/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"63","NARRATIVE":"HANGING CURTON PUT KNEE DOWN ON ROCK","sourceDate":"2005-07-28"},{"SOURCE_ROW_NUMBER":"127808","DOCUMENT_NO":"220051860087","ACCIDENT_DT":"06/27/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"78","NARRATIVE":"PUTTING CATHEAD ON BUGGY CABLE.  TWISTED RIGHT KNEE.","sourceDate":"2005-06-27"},{"SOURCE_ROW_NUMBER":"205436","DOCUMENT_NO":"220051290084","ACCIDENT_DT":"04/22/2005","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"CHANGING DOWLS ON MINER HEAD, HIT RIGHT SHOULDER ON MINER HEAD","sourceDate":"2005-04-22"},{"SOURCE_ROW_NUMBER":"192480","DOCUMENT_NO":"220041880072","ACCIDENT_DT":"06/29/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"WHILE TRAVELING #5 HEADING OF OUR SOUTH MAINS A ROOF FALL MEASURING 600' IN LENGTH; 20' IN WIDTH; APPROXIMATELY 36' HIGH WAS DISCOVERED ON A 7 DAY CHECK. THIS FALL WILL NOT BE CLEANED UP. IT DOES NOT ADVERSLEY AIR COURSES OR TRAVELWAYS.","sourceDate":"2004-06-29"},{"SOURCE_ROW_NUMBER":"93473","DOCUMENT_NO":"220041810019","ACCIDENT_DT":"06/23/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A ROCK FALL LOCATED 60 INBY S.S# 728 MEASURING 120' IN LENGTH & 120'WIDTH WAS DISCOVERED ON OUR WEEKLY EXAM OF WORKED OUT AREAS. THIS FALL WILL NOT BE CLEANED UP. THE FALL WAS DANGERED OFF. THE RETURN AIR COURSE IS NOT AFFECTED BY THE FALL.","sourceDate":"2004-06-23"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2011-01-28","lastDate":"2011-01-28","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":585,"firstDate":"2001-08-03","lastDate":"2010-06-23","metrics":{"ss":187,"delinquent":585,"recentRows":0,"paidPenalty":54302.87,"proposedPenalty":153955,"currentAssessment":87280},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1371309","VIOLATION_NO":"8176073","ISSUE_DT":"06/23/2010","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"1371308","VIOLATION_NO":"8176072","ISSUE_DT":"06/23/2010","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"1371307","VIOLATION_NO":"8176071","ISSUE_DT":"06/23/2010","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"1371305","VIOLATION_NO":"8171757","ISSUE_DT":"06/04/2010","CFR_STANDARD_CD":"75.380(d)(7)(iv)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-04"},{"SOURCE_ROW_NUMBER":"1371304","VIOLATION_NO":"8171756","ISSUE_DT":"06/03/2010","CFR_STANDARD_CD":"75.362(d)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-03"},{"SOURCE_ROW_NUMBER":"1371303","VIOLATION_NO":"8171755","ISSUE_DT":"06/03/2010","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"308.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-06-03"},{"SOURCE_ROW_NUMBER":"1337587","VIOLATION_NO":"8171303","ISSUE_DT":"05/18/2010","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"1337593","VIOLATION_NO":"8176486","ISSUE_DT":"04/19/2010","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-04-19"},{"SOURCE_ROW_NUMBER":"1337592","VIOLATION_NO":"8176485","ISSUE_DT":"04/19/2010","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-04-19"},{"SOURCE_ROW_NUMBER":"1337591","VIOLATION_NO":"8176484","ISSUE_DT":"04/16/2010","CFR_STANDARD_CD":"77.1707(b)(5)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-04-16"},{"SOURCE_ROW_NUMBER":"1337590","VIOLATION_NO":"8176483","ISSUE_DT":"04/15/2010","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2901.00","CURRENT_ASSESSMENT_AMT":"807.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-04-15"},{"SOURCE_ROW_NUMBER":"1337589","VIOLATION_NO":"8176482","ISSUE_DT":"04/15/2010","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-04-15"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":119,"firstDate":"2005-02-02","lastDate":"2012-07-18","metrics":{"appeals":0,"decisions":119,"recentRows":0,"decisionPenalty":22432,"originalPenalty":89207},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"283485","VIOLATION_NO":"8176071","DOCKET_NO":"VA 2010-600","DECISION_DT":"07/18/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"George","JUDGE_LAST_NAME":"Koutras","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"61435","VIOLATION_NO":"8176073","DOCKET_NO":"VA 2010-601","DECISION_DT":"07/18/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"George","JUDGE_LAST_NAME":"Koutras","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"61434","VIOLATION_NO":"8176072","DOCKET_NO":"VA 2010-601","DECISION_DT":"07/18/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":"117.00","JUDGE_FIRST_NAME":"George","JUDGE_LAST_NAME":"Koutras","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"270608","VIOLATION_NO":"8165294","DOCKET_NO":"VA 2010-265","DECISION_DT":"07/09/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"971.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2012-07-09"},{"SOURCE_ROW_NUMBER":"53678","VIOLATION_NO":"8165295","DOCKET_NO":"VA 2010-265","DECISION_DT":"07/09/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2161.00","DECISION_PENALTY_AMT":"971.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2012-07-09"},{"SOURCE_ROW_NUMBER":"281268","VIOLATION_NO":"8171303","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"280712","VIOLATION_NO":"8171757","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"224.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"280064","VIOLATION_NO":"8171755","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"138.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"60092","VIOLATION_NO":"8171756","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"278919","VIOLATION_NO":"8167714","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2011-09-22"},{"SOURCE_ROW_NUMBER":"278918","VIOLATION_NO":"8167711","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2011-09-22"},{"SOURCE_ROW_NUMBER":"278693","VIOLATION_NO":"8167719","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2011-09-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":511,"firstDate":"2000-01-12","lastDate":"2010-06-19","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":44,"validSamples":467,"maxConcentration":6.671,"concentrationTotal":270.132},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147160","CASS_NUM":"51068066","SMP_TAKEN_DT":"6/19/2010","CONC":"1.234","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-06-19"},{"SOURCE_ROW_NUMBER":"1348733","CASS_NUM":"51068040","SMP_TAKEN_DT":"6/18/2010","CONC":".487","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-06-18"},{"SOURCE_ROW_NUMBER":"473731","CASS_NUM":"51061684","SMP_TAKEN_DT":"6/17/2010","CONC":".375","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-06-17"},{"SOURCE_ROW_NUMBER":"89043","CASS_NUM":"51061707","SMP_TAKEN_DT":"6/16/2010","CONC":".29","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-06-16"},{"SOURCE_ROW_NUMBER":"434265","CASS_NUM":"51067995","SMP_TAKEN_DT":"6/15/2010","CONC":".441","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-06-15"},{"SOURCE_ROW_NUMBER":"1003260","CASS_NUM":"51061661","SMP_TAKEN_DT":"5/20/2010","CONC":".426","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-20"},{"SOURCE_ROW_NUMBER":"1183932","CASS_NUM":"51061682","SMP_TAKEN_DT":"5/19/2010","CONC":".47","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-19"},{"SOURCE_ROW_NUMBER":"759380","CASS_NUM":"51061654","SMP_TAKEN_DT":"5/19/2010","CONC":".396","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-19"},{"SOURCE_ROW_NUMBER":"1549144","CASS_NUM":"57865800","SMP_TAKEN_DT":"5/18/2010","CONC":".168","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"1465416","CASS_NUM":"57865786","SMP_TAKEN_DT":"5/18/2010","CONC":".319","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"1374122","CASS_NUM":"57865696","SMP_TAKEN_DT":"5/18/2010","CONC":".429","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"1358088","CASS_NUM":"57865479","SMP_TAKEN_DT":"5/18/2010","CONC":".172","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-18"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":7,"firstDate":"2005-05-05","lastDate":"2009-11-12","metrics":{"linkedIssuances":7},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":119,"firstDate":"2004-07-29","lastDate":"2010-06-23","metrics":{"decisions":119,"ssChanged":8,"recentRows":0,"decisionPenalty":22432,"proposedPenalty":89207},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"301714","CITATION_NO":"8176073","CITATION_ISSUE_DT":"06/23/2010","DOCKET_NO":"VA 2010-601","DECISION_DT":"07/18/2012","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"245484","CITATION_NO":"8176072","CITATION_ISSUE_DT":"06/23/2010","DOCKET_NO":"VA 2010-601","DECISION_DT":"07/18/2012","CFR_STANDARD_CODE":"75.360(f)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":"117.00","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"133185","CITATION_NO":"8176071","CITATION_ISSUE_DT":"06/23/2010","DOCKET_NO":"VA 2010-600","DECISION_DT":"07/18/2012","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"245976","CITATION_NO":"8171757","CITATION_ISSUE_DT":"06/04/2010","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"224.00","sourceDate":"2010-06-04"},{"SOURCE_ROW_NUMBER":"360963","CITATION_NO":"8171755","CITATION_ISSUE_DT":"06/03/2010","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"138.00","sourceDate":"2010-06-03"},{"SOURCE_ROW_NUMBER":"135361","CITATION_NO":"8171756","CITATION_ISSUE_DT":"06/03/2010","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","CFR_STANDARD_CODE":"75.362(d)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2010-06-03"},{"SOURCE_ROW_NUMBER":"133296","CITATION_NO":"8171303","CITATION_ISSUE_DT":"05/18/2010","DOCKET_NO":"VA 2010-540","DECISION_DT":"11/30/2011","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"416527","CITATION_NO":"8176485","CITATION_ISSUE_DT":"04/19/2010","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"176.00","sourceDate":"2010-04-19"},{"SOURCE_ROW_NUMBER":"359579","CITATION_NO":"8176486","CITATION_ISSUE_DT":"04/19/2010","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2010-04-19"},{"SOURCE_ROW_NUMBER":"188994","CITATION_NO":"8176484","CITATION_ISSUE_DT":"04/16/2010","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","CFR_STANDARD_CODE":"77.1707(b)(5)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2010-04-16"},{"SOURCE_ROW_NUMBER":"414654","CITATION_NO":"8176481","CITATION_ISSUE_DT":"04/15/2010","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","CFR_STANDARD_CODE":"75.333(e)(1)(ii)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2010-04-15"},{"SOURCE_ROW_NUMBER":"358271","CITATION_NO":"8167720","CITATION_ISSUE_DT":"04/15/2010","DOCKET_NO":"VA 2010-473","DECISION_DT":"09/22/2011","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2010-04-15"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":367,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":78,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1985-03-01","lastDate":"2008-03-03","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":99,"firstDate":"2000-03-24","lastDate":"2011-01-25","metrics":{"inspectors":149,"recentRows":0,"onSiteHours":2571,"inspectionHours":3878,"inspectionSamples":420},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"828387","EVENT_NO":"4413071","INSPECTION_BEGIN_DT":"01/25/2011","INSPECTION_END_DT":"01/28/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.75","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2011-01-25"},{"SOURCE_ROW_NUMBER":"678059","EVENT_NO":"4413049","INSPECTION_BEGIN_DT":"08/19/2010","INSPECTION_END_DT":"08/23/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2010-08-19"},{"SOURCE_ROW_NUMBER":"531077","EVENT_NO":"4412012","INSPECTION_BEGIN_DT":"06/22/2010","INSPECTION_END_DT":"06/23/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2010-06-22"},{"SOURCE_ROW_NUMBER":"348189","EVENT_NO":"4412010","INSPECTION_BEGIN_DT":"06/16/2010","INSPECTION_END_DT":"06/16/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2010-06-16"},{"SOURCE_ROW_NUMBER":"922104","EVENT_NO":"4412007","INSPECTION_BEGIN_DT":"06/03/2010","INSPECTION_END_DT":"06/10/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.75","SUM_TOTAL_ON_SITE_HOURS":"10.25","sourceDate":"2010-06-03"},{"SOURCE_ROW_NUMBER":"318057","EVENT_NO":"4131974","INSPECTION_BEGIN_DT":"05/04/2010","INSPECTION_END_DT":"05/14/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.25","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2010-05-04"},{"SOURCE_ROW_NUMBER":"32991","EVENT_NO":"4131973","INSPECTION_BEGIN_DT":"04/07/2010","INSPECTION_END_DT":"04/07/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.25","SUM_TOTAL_ON_SITE_HOURS":"3.75","sourceDate":"2010-04-07"},{"SOURCE_ROW_NUMBER":"914153","EVENT_NO":"4403835","INSPECTION_BEGIN_DT":"04/01/2010","INSPECTION_END_DT":"05/25/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"161.5","SUM_TOTAL_ON_SITE_HOURS":"117.5","sourceDate":"2010-04-01"},{"SOURCE_ROW_NUMBER":"953730","EVENT_NO":"4406788","INSPECTION_BEGIN_DT":"03/22/2010","INSPECTION_END_DT":"03/29/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"36","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2010-03-22"},{"SOURCE_ROW_NUMBER":"63227","EVENT_NO":"4131970","INSPECTION_BEGIN_DT":"03/17/2010","INSPECTION_END_DT":"03/31/2010","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"10.75","sourceDate":"2010-03-17"},{"SOURCE_ROW_NUMBER":"110718","EVENT_NO":"4403388","INSPECTION_BEGIN_DT":"03/10/2010","INSPECTION_END_DT":"03/22/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"28.5","SUM_TOTAL_ON_SITE_HOURS":"19.75","sourceDate":"2010-03-10"},{"SOURCE_ROW_NUMBER":"407585","EVENT_NO":"4403334","INSPECTION_BEGIN_DT":"03/09/2010","INSPECTION_END_DT":"04/05/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"43","SUM_TOTAL_ON_SITE_HOURS":"27.75","sourceDate":"2010-03-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":76,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011-Q1":{"hours":0,"employees":0,"production":0},"2010-Q3":{"hours":5345,"employees":12,"production":1226},"2010-Q2":{"hours":8442,"employees":12,"production":15744},"2010-Q1":{"hours":15131,"employees":27,"production":26629},"2009-Q4":{"hours":12806,"employees":27,"production":23983},"2009-Q3":{"hours":8505,"employees":14,"production":30021},"2009-Q2":{"hours":8961,"employees":14,"production":11105},"2009-Q1":{"hours":8017,"employees":14,"production":13460},"2008-Q4":{"hours":6592,"employees":16,"production":12540},"2008-Q3":{"hours":5547,"employees":16,"production":14847},"2008-Q2":{"hours":5962,"employees":13,"production":7043},"2008-Q1":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":18,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":10108,"employees":13,"production":12904},"2002":{"hours":9636,"employees":14,"production":17667},"2004":{"hours":19500,"employees":13,"production":23962},"2005":{"hours":41083,"employees":14,"production":57742},"2006":{"hours":20818,"employees":15,"production":38242},"2007":{"hours":24098,"employees":28,"production":43091},"2008":{"hours":18101,"employees":15,"production":34430},"2009":{"hours":38289,"employees":18,"production":78569},"2010":{"hours":28918,"employees":17,"production":43599}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":65,"firstDate":"2002-01-10","lastDate":"2009-11-24","metrics":{"recentRows":0,"doseOver100":12,"actDoseTotal":4993,"pelDoseTotal":3873},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"199236","EVENT_NO":"4406771","SURVEY_DATE":"11/24/2009","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"27","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2009-11-24"},{"SOURCE_ROW_NUMBER":"199235","EVENT_NO":"4406771","SURVEY_DATE":"11/03/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"058","ACT_DOSE_85":"85","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2009-11-03"},{"SOURCE_ROW_NUMBER":"199234","EVENT_NO":"4406771","SURVEY_DATE":"11/03/2009","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"47","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2009-11-03"},{"SOURCE_ROW_NUMBER":"199233","EVENT_NO":"4406771","SURVEY_DATE":"11/03/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"80","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2009-11-03"},{"SOURCE_ROW_NUMBER":"199232","EVENT_NO":"4406771","SURVEY_DATE":"11/03/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"56","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2009-11-03"},{"SOURCE_ROW_NUMBER":"199231","EVENT_NO":"4406771","SURVEY_DATE":"11/03/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2009-11-03"},{"SOURCE_ROW_NUMBER":"199225","EVENT_NO":"4406722","SURVEY_DATE":"09/14/2009","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2009-09-14"},{"SOURCE_ROW_NUMBER":"199230","EVENT_NO":"4406722","SURVEY_DATE":"09/10/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"63","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2009-09-10"},{"SOURCE_ROW_NUMBER":"199229","EVENT_NO":"4406722","SURVEY_DATE":"09/10/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2009-09-10"},{"SOURCE_ROW_NUMBER":"199228","EVENT_NO":"4406722","SURVEY_DATE":"09/10/2009","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"107","PEL_DOSE_90":"93","SURVEY_TYPE":"I","sourceDate":"2009-09-10"},{"SOURCE_ROW_NUMBER":"199227","EVENT_NO":"4406722","SURVEY_DATE":"09/10/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"51","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2009-09-10"},{"SOURCE_ROW_NUMBER":"199226","EVENT_NO":"4406722","SURVEY_DATE":"09/10/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"57","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2009-09-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":43,"firstDate":"2004-07-21","lastDate":"2010-05-18","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":12.6,"validSamples":41,"quartzPctTotal":225.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"133778","CASSETTE_NO":"57865563","SAMPLE_DT":"05/18/2010","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"68018","CASSETTE_NO":"57865557","SAMPLE_DT":"05/18/2010","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"105336","CASSETTE_NO":"57844944","SAMPLE_DT":"02/04/2010","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-04"},{"SOURCE_ROW_NUMBER":"88082","CASSETTE_NO":"57850853","SAMPLE_DT":"12/08/2009","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-12-08"},{"SOURCE_ROW_NUMBER":"41562","CASSETTE_NO":"57850884","SAMPLE_DT":"12/08/2009","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-12-08"},{"SOURCE_ROW_NUMBER":"71260","CASSETTE_NO":"57774865","SAMPLE_DT":"11/19/2008","QUARTZ_PCT":"02.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-11-19"},{"SOURCE_ROW_NUMBER":"124610","CASSETTE_NO":"57744199","SAMPLE_DT":"06/10/2008","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-06-10"},{"SOURCE_ROW_NUMBER":"22541","CASSETTE_NO":"50940850","SAMPLE_DT":"01/17/2008","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-01-17"},{"SOURCE_ROW_NUMBER":"164970","CASSETTE_NO":"57685032","SAMPLE_DT":"06/14/2007","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-14"},{"SOURCE_ROW_NUMBER":"77372","CASSETTE_NO":"57671802","SAMPLE_DT":"04/24/2007","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"69359","CASSETTE_NO":"57671855","SAMPLE_DT":"04/24/2007","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"146917","CASSETTE_NO":"57629342","SAMPLE_DT":"03/21/2007","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":590,"firstDate":"2001-08-03","lastDate":"2010-06-23","metrics":{"ss":186,"amountDue":87280,"contested":118,"amountPaid":54302.87,"recentRows":0,"section104d":1,"unterminated":0,"proposedPenalty":153955},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2341288","VIOLATION_NO":"8176073","VIOLATION_ISSUE_DT":"06/23/2010","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/23/2010","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-601","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"2341287","VIOLATION_NO":"8176072","VIOLATION_ISSUE_DT":"06/23/2010","SIG_SUB":"N","PART_SECTION":"75.360(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/23/2010","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-601","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"2341286","VIOLATION_NO":"8176071","VIOLATION_ISSUE_DT":"06/23/2010","SIG_SUB":"N","SECTION_OF_ACT":"316(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/23/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-600","sourceDate":"2010-06-23"},{"SOURCE_ROW_NUMBER":"2341242","VIOLATION_NO":"8171757","VIOLATION_ISSUE_DT":"06/04/2010","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(iv)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2010","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-540","sourceDate":"2010-06-04"},{"SOURCE_ROW_NUMBER":"2341241","VIOLATION_NO":"8171756","VIOLATION_ISSUE_DT":"06/03/2010","SIG_SUB":"N","PART_SECTION":"75.362(d)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/03/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-540","sourceDate":"2010-06-03"},{"SOURCE_ROW_NUMBER":"2341240","VIOLATION_NO":"8171755","VIOLATION_ISSUE_DT":"06/03/2010","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/03/2010","PROPOSED_PENALTY":"308","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-540","sourceDate":"2010-06-03"},{"SOURCE_ROW_NUMBER":"2341165","VIOLATION_NO":"8171303","VIOLATION_ISSUE_DT":"05/18/2010","SIG_SUB":"N","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/19/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-540","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"2341171","VIOLATION_NO":"8176486","VIOLATION_ISSUE_DT":"04/19/2010","SIG_SUB":"Y","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2010","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-473","sourceDate":"2010-04-19"},{"SOURCE_ROW_NUMBER":"2341170","VIOLATION_NO":"8176485","VIOLATION_ISSUE_DT":"04/19/2010","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/19/2010","PROPOSED_PENALTY":"392","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-473","sourceDate":"2010-04-19"},{"SOURCE_ROW_NUMBER":"2341169","VIOLATION_NO":"8176484","VIOLATION_ISSUE_DT":"04/16/2010","SIG_SUB":"N","PART_SECTION":"77.1707(b)(5)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-473","sourceDate":"2010-04-16"},{"SOURCE_ROW_NUMBER":"2341168","VIOLATION_NO":"8176483","VIOLATION_ISSUE_DT":"04/15/2010","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/27/2010","PROPOSED_PENALTY":"2901","AMOUNT_DUE":"807","AMOUNT_PAID":"807","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-473","sourceDate":"2010-04-15"},{"SOURCE_ROW_NUMBER":"2341167","VIOLATION_NO":"8176482","VIOLATION_ISSUE_DT":"04/15/2010","SIG_SUB":"Y","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/15/2010","PROPOSED_PENALTY":"425","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-473","sourceDate":"2010-04-15"}]}],"safety":{"href":"/api/v1/mines/4406195/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4406195/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"First aid equipment; location; minimum requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1707","part":"77","subchapter":"O","subpart":"R","id":"77.1707","citation":"30 CFR 77.1707","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4406195","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}