{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4405815","name":"Mine No 4","status":"Abandoned","status_date":"2013-03-20","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Roda","operator_id":"P22270","operator_name":"Guest Mountain Mining Corporation","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":36.993888,"longitude":-82.825},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":3603},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4405815","name":"Mine No 4"},"operator":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P12960","name":"Double M No 2 Mine Inc"},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"1981-12-01","validTo":"1999-11-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P12960|1981-12-01|1999-11-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03830","name":"Clyde A  Mullins"},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"1981-12-01","validTo":"1999-11-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|C03830|1981-12-01|1999-11-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03830","name":"Clyde A  Mullins"},"object":{"type":"operator","id":"P12960","name":"Double M No 2 Mine Inc"},"validFrom":"1981-12-01","validTo":"1999-11-30","current":false,"derived":true,"evidenceMineId":"4405815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P12960|1981-12-01|C03830|1981-12-01|63990"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"1993-03-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|C07082|1993-03-01|2010-04-18"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24350","name":"Appalachia Coal Company Inc"},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"1999-12-01","validTo":"2007-05-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P24350|1999-12-01|2007-05-17"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15904","name":"Harold  Sturgill"},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"1999-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|C15904|1999-12-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15904","name":"Harold  Sturgill"},"object":{"type":"operator","id":"P24350","name":"Appalachia Coal Company Inc"},"validFrom":"1999-12-01","validTo":"2007-05-17","current":false,"derived":true,"evidenceMineId":"4405815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P24350|1999-12-01|C15904|1999-12-01|97548"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"2007-05-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P22270|2007-05-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2007-05-18","validTo":"2010-04-18","current":false,"derived":true,"evidenceMineId":"4405815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P22270|2007-05-18|C07082|1993-03-01|73673"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|C02508|2010-04-19|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"4405815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P22270|2007-05-18|C02508|2010-04-19|59585"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"4405815","name":"Mine No 4"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22270","name":"Guest Mountain Mining Corporation"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4405815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405815|P22270|2007-05-18|0041211|2011-06-01|2278"}}],"coverage":{"historyRecords":5,"edgeCount":13,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":35,"firstDate":"2001-04-24","lastDate":"2013-02-05","metrics":{"daysLost":1004,"injuries":24,"fatalities":0,"recentRows":0,"restrictedDays":8,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"16192","DOCUMENT_NO":"220132960002","ACCIDENT_DT":"02/05/2013","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has filed a hearing loss claim dated February 5, 2013, with the Virginia Workers' Compensation Commission. As per the audiologist's report, employee suffers from \"moderate sloping to severe sensorineuria loss.\" Employee's last date of service with company was 10/21/2012. **THERE ARE NO ACCIDENTS ASSOCIATED WITH THIS CLAIM.**","sourceDate":"2013-02-05"},{"SOURCE_ROW_NUMBER":"89267","DOCUMENT_NO":"220101180040","ACCIDENT_DT":"04/22/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The individual was tightening the steering arm bolts with a wrench when he felt pain in his left arm and shoulder. This is a medical only reportable accident as the indiviual performed his normal duties and did not have any lost or restricted work days.","sourceDate":"2010-04-22"},{"SOURCE_ROW_NUMBER":"136505","DOCUMENT_NO":"220100120025","ACCIDENT_DT":"01/07/2010","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The individual was getting out of the operator's compartment of the roof drift and twisted around. He said he felt something pop in his chest.","sourceDate":"2010-01-07"},{"SOURCE_ROW_NUMBER":"257093","DOCUMENT_NO":"220093270059","ACCIDENT_DT":"11/16/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The individual had been grinding in the shop area. When he finished he rubbed his eyes with his hands and got a sliver of metal in his right eye. He was wearing prescription safety glasses while he was grinding. The individual received prescription medication for his eye.","sourceDate":"2009-11-16"},{"SOURCE_ROW_NUMBER":"209738","DOCUMENT_NO":"220093380033","ACCIDENT_DT":"10/27/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"173","NARRATIVE":"The conditions were wet had a light drizzle rain all day.","sourceDate":"2009-10-27"},{"SOURCE_ROW_NUMBER":"218353","DOCUMENT_NO":"220082660042","ACCIDENT_DT":"09/08/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"98","NARRATIVE":"The employee alleges that he was hanging a miner cable and had it on his shoulder. The cable pulled him to the ground, resulting in a possible bruise to his hip. The alleged injury is still under investigation and we reserve the right to withdraw the report upon completion of the investigation.","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"274208","DOCUMENT_NO":"220082530046","ACCIDENT_DT":"06/06/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"267","NARRATIVE":"Employee got truck out of gear on hill to slow truck down. He steered truck into drainage ditch; impact from going into ditch caused water tank to become loose and come into cab on driver.","sourceDate":"2008-06-06"},{"SOURCE_ROW_NUMBER":"226974","DOCUMENT_NO":"220081010053","ACCIDENT_DT":"04/04/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Excessive rain caused the highwall above the belt portal entry to erode. The additional weight of the wet material on the canopy caused the portal canopy to partially collapse onto the belt conveyor. Ventilation was not affected ant there were no injuries or equipment involved. A new canopy has been installed.","sourceDate":"2008-04-04"},{"SOURCE_ROW_NUMBER":"33412","DOCUMENT_NO":"220080090035","ACCIDENT_DT":"01/07/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall was discovered on the No 1 south panel, which was being pillared. The fall was discovered in the No 5 entry, just inby survey station 3219. The fall was an extension of a pillar fall which extended outby the break-line about 60'. The fall was 20' wide X approx 5' high. There were no injuries or equipment involved.","sourceDate":"2008-01-07"},{"SOURCE_ROW_NUMBER":"162430","DOCUMENT_NO":"220073530044","ACCIDENT_DT":"12/10/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"The individual was lifting a timber and strained his back.","sourceDate":"2007-12-10"},{"SOURCE_ROW_NUMBER":"63376","DOCUMENT_NO":"220080700063","ACCIDENT_DT":"11/29/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"75","NARRATIVE":"The employee was working on the section conveyor belt tailpiece when his wrench slipped. When the wrench slipped it caused him to strike his elbow against the tailpiece. He worked his regular job until 2-26-08. He did not miss work or receive medical treatment until 2-26-08.","sourceDate":"2007-11-29"},{"SOURCE_ROW_NUMBER":"132117","DOCUMENT_NO":"220073300035","ACCIDENT_DT":"11/17/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The EE was installing a roof bolt, when a piece of rock fell from the mine roof and caught his finger against the drill head. This resulted in a laceration which required sutures.","sourceDate":"2007-11-17"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2013-03-20","lastDate":"2013-03-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":715,"firstDate":"2000-01-28","lastDate":"2011-10-04","metrics":{"ss":318,"delinquent":684,"recentRows":0,"paidPenalty":247908.24,"proposedPenalty":501317,"currentAssessment":262145},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1365270","VIOLATION_NO":"8187865","ISSUE_DT":"10/04/2011","CFR_STANDARD_CD":"77.401(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2473.00","CURRENT_ASSESSMENT_AMT":"2473.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-04"},{"SOURCE_ROW_NUMBER":"1365269","VIOLATION_NO":"8187864","ISSUE_DT":"10/04/2011","CFR_STANDARD_CD":"77.402","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2473.00","CURRENT_ASSESSMENT_AMT":"2473.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-10-04"},{"SOURCE_ROW_NUMBER":"935236","VIOLATION_NO":"6631336","ISSUE_DT":"05/26/2010","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"935254","VIOLATION_NO":"8168574","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.362(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935253","VIOLATION_NO":"8168573","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935252","VIOLATION_NO":"8168572","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935251","VIOLATION_NO":"8168571","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935250","VIOLATION_NO":"8168570","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.380(d)(7)(vi)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935249","VIOLATION_NO":"8168569","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.380(d)(7)(vii)(B)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935248","VIOLATION_NO":"8168568","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.380(d)(7)(vii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935247","VIOLATION_NO":"8168567","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.380(d)(7)(vii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"935246","VIOLATION_NO":"8168566","ISSUE_DT":"05/06/2010","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-06"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":119,"firstDate":"2008-04-14","lastDate":"2011-10-14","metrics":{"appeals":0,"decisions":119,"recentRows":0,"decisionPenalty":172763,"originalPenalty":412035},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"233970","VIOLATION_NO":"6635494","DOCKET_NO":"VA 2009-74","DECISION_DT":"10/14/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55000.00","DECISION_PENALTY_AMT":"3421.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2011-10-14"},{"SOURCE_ROW_NUMBER":"233969","VIOLATION_NO":"6635493","DOCKET_NO":"VA 2009-74","DECISION_DT":"10/14/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60000.00","DECISION_PENALTY_AMT":"3421.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2011-10-14"},{"SOURCE_ROW_NUMBER":"232827","VIOLATION_NO":"6635497","DOCKET_NO":"VA 2009-74","DECISION_DT":"10/14/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"50000.00","DECISION_PENALTY_AMT":"50000.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2011-10-14"},{"SOURCE_ROW_NUMBER":"229318","VIOLATION_NO":"6635498","DOCKET_NO":"VA 2009-25","DECISION_DT":"10/14/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"3405.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2011-10-14"},{"SOURCE_ROW_NUMBER":"29266","VIOLATION_NO":"6635496","DOCKET_NO":"VA 2009-25","DECISION_DT":"10/14/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3405.00","DECISION_PENALTY_AMT":"3405.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2011-10-14"},{"SOURCE_ROW_NUMBER":"270985","VIOLATION_NO":"8168038","DOCKET_NO":"VA 2010-301","DECISION_DT":"08/30/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"38500.00","DECISION_PENALTY_AMT":"15000.00","JUDGE_FIRST_NAME":"George","JUDGE_LAST_NAME":"Koutras","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"54926","VIOLATION_NO":"8168039","DOCKET_NO":"VA 2010-301","DECISION_DT":"08/30/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"38500.00","DECISION_PENALTY_AMT":"5000.00","JUDGE_FIRST_NAME":"George","JUDGE_LAST_NAME":"Koutras","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"224033","VIOLATION_NO":"6635479","DOCKET_NO":"VA 2008-340","DECISION_DT":"08/05/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"263.00","DECISION_PENALTY_AMT":"176.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2011-08-05"},{"SOURCE_ROW_NUMBER":"224032","VIOLATION_NO":"6635293","DOCKET_NO":"VA 2008-340","DECISION_DT":"08/05/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2011-08-05"},{"SOURCE_ROW_NUMBER":"25558","VIOLATION_NO":"6635286","DOCKET_NO":"VA 2008-340","DECISION_DT":"08/05/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"190.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2011-08-05"},{"SOURCE_ROW_NUMBER":"271905","VIOLATION_NO":"8166563","DOCKET_NO":"VA 2010-296","DECISION_DT":"07/05/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"243.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-07-05"},{"SOURCE_ROW_NUMBER":"271904","VIOLATION_NO":"8166562","DOCKET_NO":"VA 2010-296","DECISION_DT":"07/05/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"243.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-07-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":955,"firstDate":"2000-04-12","lastDate":"2010-06-01","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":87,"validSamples":868,"maxConcentration":9.918,"concentrationTotal":577.609},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"613577","CASS_NUM":"51082277","SMP_TAKEN_DT":"6/1/2010","CONC":".495","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-06-01"},{"SOURCE_ROW_NUMBER":"1550560","CASS_NUM":"57858117","SMP_TAKEN_DT":"5/26/2010","CONC":".659","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"1368675","CASS_NUM":"57858063","SMP_TAKEN_DT":"5/26/2010","CONC":".313","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"1155040","CASS_NUM":"57858074","SMP_TAKEN_DT":"5/26/2010","CONC":".03","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"1057475","CASS_NUM":"57858120","SMP_TAKEN_DT":"5/26/2010","CONC":".51","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"1002852","CASS_NUM":"57858093","SMP_TAKEN_DT":"5/26/2010","CONC":".332","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"763728","CASS_NUM":"57858161","SMP_TAKEN_DT":"5/26/2010","CONC":".35","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"67432","CASS_NUM":"57858173","SMP_TAKEN_DT":"5/26/2010","CONC":".35","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"1588482","CASS_NUM":"51082981","SMP_TAKEN_DT":"4/29/2010","CONC":".43","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-04-29"},{"SOURCE_ROW_NUMBER":"494203","CASS_NUM":"51082978","SMP_TAKEN_DT":"4/29/2010","CONC":".542","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-04-29"},{"SOURCE_ROW_NUMBER":"841165","CASS_NUM":"51082985","SMP_TAKEN_DT":"4/28/2010","CONC":".403","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-04-28"},{"SOURCE_ROW_NUMBER":"746098","CASS_NUM":"51082970","SMP_TAKEN_DT":"4/28/2010","CONC":".437","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-04-28"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":13,"firstDate":"2007-09-05","lastDate":"2008-09-10","metrics":{"linkedIssuances":13},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":119,"firstDate":"2007-08-15","lastDate":"2010-05-20","metrics":{"decisions":119,"ssChanged":4,"recentRows":0,"decisionPenalty":172763,"proposedPenalty":412035},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"57349","CITATION_NO":"6631312","CITATION_ISSUE_DT":"05/20/2010","DOCKET_NO":"VA 2010-495","DECISION_DT":"04/04/2011","CFR_STANDARD_CODE":"41.13","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"138.00","DECISION_PENALTY_AMT":"138.00","sourceDate":"2010-05-20"},{"SOURCE_ROW_NUMBER":"418994","CITATION_NO":"8168563","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.523-3(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"1111.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"418365","CITATION_NO":"8168562","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.523-1(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"745.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"360398","CITATION_NO":"8168573","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"745.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"245482","CITATION_NO":"8168561","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"192212","CITATION_NO":"8168568","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.380(d)(7)(vii)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"191591","CITATION_NO":"8168566","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"134845","CITATION_NO":"8168564","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"134844","CITATION_NO":"8168574","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.362(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"745.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"132045","CITATION_NO":"8168567","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.380(d)(7)(vii)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"79493","CITATION_NO":"8168570","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.380(d)(7)(vi)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"78801","CITATION_NO":"8168569","CITATION_ISSUE_DT":"05/06/2010","DOCKET_NO":"VA 2010-462","DECISION_DT":"12/15/2010","CFR_STANDARD_CODE":"75.380(d)(7)(vii)(B)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","sourceDate":"2010-05-06"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":327,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":68,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1981-12-01","lastDate":"2007-05-18","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":228,"firstDate":"2000-01-20","lastDate":"2013-03-20","metrics":{"inspectors":327,"recentRows":0,"onSiteHours":4200.5,"inspectionHours":7093.75,"inspectionSamples":315},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"463083","EVENT_NO":"4410391","INSPECTION_BEGIN_DT":"03/20/2013","INSPECTION_END_DT":"03/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"130690","EVENT_NO":"4410269","INSPECTION_BEGIN_DT":"07/11/2012","INSPECTION_END_DT":"07/13/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2012-07-11"},{"SOURCE_ROW_NUMBER":"1003953","EVENT_NO":"4410246","INSPECTION_BEGIN_DT":"10/04/2011","INSPECTION_END_DT":"03/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2011-10-04"},{"SOURCE_ROW_NUMBER":"767484","EVENT_NO":"4411436","INSPECTION_BEGIN_DT":"06/23/2011","INSPECTION_END_DT":"06/24/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.75","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2011-06-23"},{"SOURCE_ROW_NUMBER":"226229","EVENT_NO":"4411029","INSPECTION_BEGIN_DT":"03/09/2011","INSPECTION_END_DT":"03/09/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.75","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2011-03-09"},{"SOURCE_ROW_NUMBER":"537555","EVENT_NO":"4411021","INSPECTION_BEGIN_DT":"12/30/2010","INSPECTION_END_DT":"12/30/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2010-12-30"},{"SOURCE_ROW_NUMBER":"939791","EVENT_NO":"4159165","INSPECTION_BEGIN_DT":"08/11/2010","INSPECTION_END_DT":"08/27/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2010-08-11"},{"SOURCE_ROW_NUMBER":"1159604","EVENT_NO":"4414029","INSPECTION_BEGIN_DT":"07/09/2010","INSPECTION_END_DT":"07/09/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2010-07-09"},{"SOURCE_ROW_NUMBER":"946143","EVENT_NO":"4131977","INSPECTION_BEGIN_DT":"05/21/2010","INSPECTION_END_DT":"05/24/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2010-05-21"},{"SOURCE_ROW_NUMBER":"113453","EVENT_NO":"4159157","INSPECTION_BEGIN_DT":"05/04/2010","INSPECTION_END_DT":"06/25/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"108.75","SUM_TOTAL_ON_SITE_HOURS":"74.5","sourceDate":"2010-05-04"},{"SOURCE_ROW_NUMBER":"1010400","EVENT_NO":"4414002","INSPECTION_BEGIN_DT":"04/21/2010","INSPECTION_END_DT":"04/21/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2010-04-21"},{"SOURCE_ROW_NUMBER":"444093","EVENT_NO":"4159612","INSPECTION_BEGIN_DT":"03/31/2010","INSPECTION_END_DT":"03/31/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2010-03-31"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":104,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q3":{"hours":0,"employees":0,"production":0},"2012-Q2":{"hours":0,"employees":0,"production":0},"2011-Q3":{"hours":1303,"employees":3,"production":0},"2011-Q2":{"hours":1322,"employees":2,"production":0},"2011-Q1":{"hours":1345,"employees":2,"production":0},"2010-Q4":{"hours":1445,"employees":4,"production":0},"2010-Q3":{"hours":3212,"employees":8,"production":0},"2010-Q2":{"hours":20303,"employees":33,"production":49075},"2010-Q1":{"hours":23782,"employees":39,"production":104128},"2009-Q4":{"hours":21462,"employees":38,"production":99619},"2009-Q3":{"hours":22281,"employees":35,"production":79771},"2009-Q2":{"hours":22057,"employees":36,"production":93467}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":39668,"employees":20,"production":194048},"2003":{"hours":53199,"employees":23,"production":236830},"2004":{"hours":50735,"employees":22,"production":278568},"2005":{"hours":47348,"employees":21,"production":219131},"2006":{"hours":40101,"employees":17,"production":183014},"2007":{"hours":49374,"employees":23,"production":224060},"2008":{"hours":81117,"employees":32,"production":397111},"2009":{"hours":93152,"employees":38,"production":365622},"2010":{"hours":48742,"employees":22,"production":153203},"2011":{"hours":3970,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":58,"firstDate":"2000-04-18","lastDate":"2010-01-28","metrics":{"recentRows":0,"doseOver100":11,"actDoseTotal":4178,"pelDoseTotal":3057},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"198708","EVENT_NO":"4159604","SURVEY_DATE":"01/28/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"61","PEL_DOSE_90":"54","SURVEY_TYPE":"F","sourceDate":"2010-01-28"},{"SOURCE_ROW_NUMBER":"198707","EVENT_NO":"4159604","SURVEY_DATE":"01/28/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"41","PEL_DOSE_90":"40","SURVEY_TYPE":"F","sourceDate":"2010-01-28"},{"SOURCE_ROW_NUMBER":"198706","EVENT_NO":"4159604","SURVEY_DATE":"01/28/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"50","PEL_DOSE_90":"47","SURVEY_TYPE":"F","sourceDate":"2010-01-28"},{"SOURCE_ROW_NUMBER":"198705","EVENT_NO":"4159604","SURVEY_DATE":"01/28/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"67","PEL_DOSE_90":"59","SURVEY_TYPE":"F","sourceDate":"2010-01-28"},{"SOURCE_ROW_NUMBER":"198704","EVENT_NO":"4159604","SURVEY_DATE":"01/28/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"52","SURVEY_TYPE":"F","sourceDate":"2010-01-28"},{"SOURCE_ROW_NUMBER":"198703","EVENT_NO":"4159604","SURVEY_DATE":"01/28/2010","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"93","PEL_DOSE_90":"83","SURVEY_TYPE":"F","sourceDate":"2010-01-28"},{"SOURCE_ROW_NUMBER":"198714","EVENT_NO":"4407413","SURVEY_DATE":"12/01/2009","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"294","PEL_DOSE_90":"281","SURVEY_TYPE":"I","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"198713","EVENT_NO":"4407413","SURVEY_DATE":"12/01/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"75","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"198712","EVENT_NO":"4407413","SURVEY_DATE":"12/01/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"77","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"198711","EVENT_NO":"4407413","SURVEY_DATE":"12/01/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"62","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"198710","EVENT_NO":"4407413","SURVEY_DATE":"12/01/2009","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"24","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"198709","EVENT_NO":"4407413","SURVEY_DATE":"12/01/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"93","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2009-12-01"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":102,"firstDate":"2000-05-22","lastDate":"2010-05-26","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":27.3,"validSamples":99,"quartzPctTotal":706.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"156815","CASSETTE_NO":"57858117","SAMPLE_DT":"05/26/2010","QUARTZ_PCT":"12.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"35953","CASSETTE_NO":"57858093","SAMPLE_DT":"05/26/2010","QUARTZ_PCT":"27.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"21311","CASSETTE_NO":"57858063","SAMPLE_DT":"05/26/2010","QUARTZ_PCT":"26.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"136791","CASSETTE_NO":"51065787","SAMPLE_DT":"04/08/2010","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2010-04-08"},{"SOURCE_ROW_NUMBER":"166240","CASSETTE_NO":"57816573","SAMPLE_DT":"02/17/2010","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-17"},{"SOURCE_ROW_NUMBER":"141735","CASSETTE_NO":"57816602","SAMPLE_DT":"02/17/2010","QUARTZ_PCT":"11.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-17"},{"SOURCE_ROW_NUMBER":"42580","CASSETTE_NO":"57809613","SAMPLE_DT":"11/10/2009","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-11-10"},{"SOURCE_ROW_NUMBER":"21628","CASSETTE_NO":"57809605","SAMPLE_DT":"11/10/2009","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-11-10"},{"SOURCE_ROW_NUMBER":"16267","CASSETTE_NO":"57809206","SAMPLE_DT":"11/10/2009","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-11-10"},{"SOURCE_ROW_NUMBER":"156484","CASSETTE_NO":"57808923","SAMPLE_DT":"08/25/2009","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-08-25"},{"SOURCE_ROW_NUMBER":"104266","CASSETTE_NO":"57808977","SAMPLE_DT":"08/25/2009","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-08-25"},{"SOURCE_ROW_NUMBER":"81742","CASSETTE_NO":"57808925","SAMPLE_DT":"08/25/2009","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-08-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":729,"firstDate":"2000-01-28","lastDate":"2011-10-04","metrics":{"ss":317,"amountDue":262145,"contested":117,"amountPaid":247908.24,"recentRows":0,"section104d":3,"unterminated":1,"proposedPenalty":501317},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2339154","VIOLATION_NO":"8187865","VIOLATION_ISSUE_DT":"10/04/2011","SIG_SUB":"Y","PART_SECTION":"77.401(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/04/2011","PROPOSED_PENALTY":"2473","AMOUNT_DUE":"2473","AMOUNT_PAID":"2473","CONTESTED_IND":"N","sourceDate":"2011-10-04"},{"SOURCE_ROW_NUMBER":"2339153","VIOLATION_NO":"8187864","VIOLATION_ISSUE_DT":"10/04/2011","SIG_SUB":"Y","PART_SECTION":"77.402","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/04/2011","PROPOSED_PENALTY":"2473","AMOUNT_DUE":"2473","AMOUNT_PAID":"2473","CONTESTED_IND":"N","sourceDate":"2011-10-04"},{"SOURCE_ROW_NUMBER":"2338865","VIOLATION_NO":"6631336","VIOLATION_ISSUE_DT":"05/26/2010","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/26/2010","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2010-05-26"},{"SOURCE_ROW_NUMBER":"2338883","VIOLATION_NO":"8168574","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"Y","PART_SECTION":"75.362(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2010","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-462","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338882","VIOLATION_NO":"8168573","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2010","PROPOSED_PENALTY":"1111","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-462","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338881","VIOLATION_NO":"8168572","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2010","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338880","VIOLATION_NO":"8168571","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2010","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338879","VIOLATION_NO":"8168570","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(vi)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2010","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-462","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338878","VIOLATION_NO":"8168569","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(vii)(B)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/06/2010","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-462","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338877","VIOLATION_NO":"8168568","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(vii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/06/2010","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-462","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338876","VIOLATION_NO":"8168567","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(vii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/06/2010","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-462","sourceDate":"2010-05-06"},{"SOURCE_ROW_NUMBER":"2338875","VIOLATION_NO":"8168566","VIOLATION_ISSUE_DT":"05/06/2010","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2010","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-462","sourceDate":"2010-05-06"}]}],"safety":{"href":"/api/v1/mines/4405815/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4405815/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Stationary grinding machines; protective devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.401","part":"77","subchapter":"O","subpart":"E","id":"77.401","citation":"30 CFR 77.401","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Hand-held power tools; safety devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.402","part":"77","subchapter":"O","subpart":"E","id":"77.402","citation":"30 CFR 77.402","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4405815","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}