{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4405331","name":"No 3","status":"Abandoned","status_date":"2005-06-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Dickenson","nearest_town":"Dante","operator_id":"P24366","operator_name":"Cove Coal Co., Inc.","controller_id":"0044201","controller_name":"Glenn K  Mitchell; Marty  Fuller","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.025,"longitude":-82.208333},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":737},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4405331","name":"No 3"},"operator":{"type":"operator","id":"P24366","name":"Cove Coal Co., Inc."},"controller":{"type":"controller","id":"0044201","name":"Glenn K  Mitchell; Marty  Fuller"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00230","name":"Pittston Company"},"object":{"type":"mine","id":"4405331","name":"No 3"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|C00230|1950-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00653","name":"Clinchfield Coal Company"},"object":{"type":"mine","id":"4405331","name":"No 3"},"validFrom":"1979-12-01","validTo":"2001-02-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|P00653|1979-12-01|2001-02-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00230","name":"Pittston Company"},"object":{"type":"operator","id":"P00653","name":"Clinchfield Coal Company"},"validFrom":"1979-12-01","validTo":"2001-02-14","current":false,"derived":true,"evidenceMineId":"4405331","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|P00653|1979-12-01|C00230|1950-01-01|45103"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07657","name":"Eugene  Ball"},"object":{"type":"mine","id":"4405331","name":"No 3"},"validFrom":"2000-04-01","validTo":"2002-09-02","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|C07657|2000-04-01|2002-09-02"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24366","name":"Cove Coal Co., Inc."},"object":{"type":"mine","id":"4405331","name":"No 3"},"validFrom":"2001-02-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|P24366|2001-02-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07657","name":"Eugene  Ball"},"object":{"type":"operator","id":"P24366","name":"Cove Coal Co., Inc."},"validFrom":"2001-02-15","validTo":"2002-09-02","current":false,"derived":true,"evidenceMineId":"4405331","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|P24366|2001-02-15|C07657|2000-04-01|75290"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0042291","name":"Jeffrey  Cline"},"object":{"type":"mine","id":"4405331","name":"No 3"},"validFrom":"2002-09-03","validTo":"2004-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|0042291|2002-09-03|2004-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0042291","name":"Jeffrey  Cline"},"object":{"type":"operator","id":"P24366","name":"Cove Coal Co., Inc."},"validFrom":"2002-09-03","validTo":"2004-07-25","current":false,"derived":true,"evidenceMineId":"4405331","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|P24366|2001-02-15|0042291|2002-09-03|3839"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0044201","name":"Glenn K  Mitchell  et al"},"object":{"type":"mine","id":"4405331","name":"No 3"},"validFrom":"2004-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|0044201|2004-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0044201","name":"Glenn K  Mitchell  et al"},"object":{"type":"operator","id":"P24366","name":"Cove Coal Co., Inc."},"validFrom":"2004-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4405331","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|P24366|2001-02-15|0044201|2004-07-26|4932"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0044201","name":"Marty  Fuller  et al"},"object":{"type":"operator","id":"P24366","name":"Cove Coal Co., Inc."},"validFrom":"2004-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4405331","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405331|P24366|2001-02-15|0044201|2004-07-26|4933"}}],"coverage":{"historyRecords":5,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":6,"firstDate":"2002-11-19","lastDate":"2004-06-21","metrics":{"daysLost":303,"injuries":4,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"205427","DOCUMENT_NO":"220041820030","ACCIDENT_DT":"06/21/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"246","NARRATIVE":"FILLING BATTERIES ON SMALL THREE-WHEEL MANTRIP, HE STARTED FOR MORE WATER WHEN MANTRIP STARTED IN REVERSE. HIGH TRAM TRAPPED HIM BETWEEN TOP AND TOP OF MANTRIP AND ROLLED HIM IN TOP.","sourceDate":"2004-06-21"},{"SOURCE_ROW_NUMBER":"33407","DOCUMENT_NO":"220041470015","ACCIDENT_DT":"05/17/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"ROCK FALL ON INTAKE SPAD #904 TO 905.  4 FT. THICK X 20 FT. WIDE X 80 FT. LONG CROSS CUT.","sourceDate":"2004-05-17"},{"SOURCE_ROW_NUMBER":"153821","DOCUMENT_NO":"220033180026","ACCIDENT_DT":"10/29/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"WAS IN SQUATTING POSITION INSTALLING ROOF BOLTS AND DROPPED BOOM ON KNEE.","sourceDate":"2003-10-29"},{"SOURCE_ROW_NUMBER":"76443","DOCUMENT_NO":"220032680017","ACCIDENT_DT":"09/16/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"HE PICKED UP A CAN OF OIL AND TWISTED HIS BACK.","sourceDate":"2003-09-16"},{"SOURCE_ROW_NUMBER":"248506","DOCUMENT_NO":"220030970057","ACCIDENT_DT":"03/31/2003","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL ON 001-0 SECTION 70 FEET TO THE RIGHT OF SURVEY STATION 870. ENTRAPPED THE MINER. IT WAS AN UNDETECTED SLIP.","sourceDate":"2003-03-31"},{"SOURCE_ROW_NUMBER":"37734","DOCUMENT_NO":"220023360005","ACCIDENT_DT":"11/19/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"RUNNING ROOF BOLTING MACHINE PUT LEFT HAND ON BOOM OF MACHINE AND LET ATRS DOWN ON HAND.","sourceDate":"2002-11-19"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-06-01","lastDate":"2005-06-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":209,"firstDate":"2001-11-07","lastDate":"2004-08-31","metrics":{"ss":89,"delinquent":209,"recentRows":0,"paidPenalty":0,"proposedPenalty":48132,"currentAssessment":46721},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"913020","VIOLATION_NO":"7337850","ISSUE_DT":"08/31/2004","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2200.00","CURRENT_ASSESSMENT_AMT":"2200.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"913019","VIOLATION_NO":"7337849","ISSUE_DT":"08/31/2004","CFR_STANDARD_CD":"77.516","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2200.00","CURRENT_ASSESSMENT_AMT":"2200.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"913018","VIOLATION_NO":"7337848","ISSUE_DT":"08/31/2004","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2200.00","CURRENT_ASSESSMENT_AMT":"2200.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"913017","VIOLATION_NO":"7337847","ISSUE_DT":"08/31/2004","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"875.00","CURRENT_ASSESSMENT_AMT":"875.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"913016","VIOLATION_NO":"7337845","ISSUE_DT":"08/31/2004","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"525.00","CURRENT_ASSESSMENT_AMT":"525.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"880938","VIOLATION_NO":"3353787","ISSUE_DT":"08/25/2004","CFR_STANDARD_CD":"75.1715","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"750.00","CURRENT_ASSESSMENT_AMT":"750.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"880937","VIOLATION_NO":"3353786","ISSUE_DT":"08/25/2004","CFR_STANDARD_CD":"75.800-4","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"1000.00","CURRENT_ASSESSMENT_AMT":"1000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"880936","VIOLATION_NO":"3353785","ISSUE_DT":"08/25/2004","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"1000.00","CURRENT_ASSESSMENT_AMT":"1000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"880935","VIOLATION_NO":"3353784","ISSUE_DT":"08/25/2004","CFR_STANDARD_CD":"75.900-4","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"1000.00","CURRENT_ASSESSMENT_AMT":"1000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"880934","VIOLATION_NO":"3353783","ISSUE_DT":"08/25/2004","CFR_STANDARD_CD":"75.312(g)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"1000.00","CURRENT_ASSESSMENT_AMT":"1000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"880933","VIOLATION_NO":"3353782","ISSUE_DT":"08/25/2004","CFR_STANDARD_CD":"75.364(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"1000.00","CURRENT_ASSESSMENT_AMT":"1000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"880932","VIOLATION_NO":"3353781","ISSUE_DT":"08/25/2004","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"1000.00","CURRENT_ASSESSMENT_AMT":"1000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-25"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":20,"firstDate":"2003-10-07","lastDate":"2003-10-07","metrics":{"appeals":0,"decisions":20,"recentRows":0,"decisionPenalty":2245,"originalPenalty":3740},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"480838","VIOLATION_NO":"7327816","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"173.00","DECISION_PENALTY_AMT":"90.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"480653","VIOLATION_NO":"7329825","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"161.00","DECISION_PENALTY_AMT":"124.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"480478","VIOLATION_NO":"7327835","DOCKET_NO":"VA  20030099","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"184.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"480477","VIOLATION_NO":"7327820","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"173.00","DECISION_PENALTY_AMT":"90.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"480476","VIOLATION_NO":"7327818","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"173.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"479948","VIOLATION_NO":"7327837","DOCKET_NO":"VA  20030099","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"184.00","DECISION_PENALTY_AMT":"140.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"479426","VIOLATION_NO":"7329827","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"479425","VIOLATION_NO":"7327819","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"173.00","DECISION_PENALTY_AMT":"90.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"479424","VIOLATION_NO":"4380364","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"179490","VIOLATION_NO":"7327834","DOCKET_NO":"VA  20030099","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"184.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"179489","VIOLATION_NO":"7327817","DOCKET_NO":"VA  20030098","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"130.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"},{"SOURCE_ROW_NUMBER":"179190","VIOLATION_NO":"7328701","DOCKET_NO":"VA  20030099","DECISION_DT":"10/07/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"184.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-10-07"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":142,"firstDate":"2001-11-21","lastDate":"2003-12-05","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":134,"maxConcentration":14.37,"concentrationTotal":109.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"738216","CASS_NUM":"50707061","SMP_TAKEN_DT":"12/5/2003","CONC":".024","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-12-05"},{"SOURCE_ROW_NUMBER":"1398638","CASS_NUM":"50707119","SMP_TAKEN_DT":"12/4/2003","CONC":".268","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-12-04"},{"SOURCE_ROW_NUMBER":"824665","CASS_NUM":"50707091","SMP_TAKEN_DT":"12/3/2003","CONC":".479","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-12-03"},{"SOURCE_ROW_NUMBER":"1510241","CASS_NUM":"50707086","SMP_TAKEN_DT":"11/26/2003","CONC":".009","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-11-26"},{"SOURCE_ROW_NUMBER":"1017986","CASS_NUM":"50707139","SMP_TAKEN_DT":"11/26/2003","CONC":".007","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INSUFFICIENT DUST OBSERVED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-11-26"},{"SOURCE_ROW_NUMBER":"1387873","CASS_NUM":"50689479","SMP_TAKEN_DT":"11/4/2003","CONC":".092","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"CITATION SAMPLE/COMPLIANCE DURING FIRST SEVEN DAYS OF CYCLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-11-04"},{"SOURCE_ROW_NUMBER":"255856","CASS_NUM":"50707393","SMP_TAKEN_DT":"11/3/2003","CONC":".207","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"CITATION SAMPLE/COMPLIANCE DURING FIRST SEVEN DAYS OF CYCLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-11-03"},{"SOURCE_ROW_NUMBER":"97872","CASS_NUM":"50689448","SMP_TAKEN_DT":"10/31/2003","CONC":".004","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-10-31"},{"SOURCE_ROW_NUMBER":"1338186","CASS_NUM":"50689447","SMP_TAKEN_DT":"10/30/2003","CONC":".041","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-10-30"},{"SOURCE_ROW_NUMBER":"720303","CASS_NUM":"50689480","SMP_TAKEN_DT":"10/29/2003","CONC":".035","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-10-29"},{"SOURCE_ROW_NUMBER":"1379397","CASS_NUM":"50707416","SMP_TAKEN_DT":"10/28/2003","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-10-28"},{"SOURCE_ROW_NUMBER":"1231598","CASS_NUM":"50707469","SMP_TAKEN_DT":"10/6/2003","CONC":"3.829","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-10-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":16,"firstDate":"2003-04-08","lastDate":"2003-04-08","metrics":{"linkedIssuances":16},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1979-12-01","lastDate":"2001-02-15","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":60,"firstDate":"2001-04-18","lastDate":"2005-01-05","metrics":{"inspectors":77,"recentRows":0,"onSiteHours":813.75,"inspectionHours":1585.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"204128","EVENT_NO":"4144902","INSPECTION_BEGIN_DT":"01/05/2005","INSPECTION_END_DT":"03/16/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2005-01-05"},{"SOURCE_ROW_NUMBER":"898170","EVENT_NO":"4144900","INSPECTION_BEGIN_DT":"11/29/2004","INSPECTION_END_DT":"12/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-11-29"},{"SOURCE_ROW_NUMBER":"664285","EVENT_NO":"4127931","INSPECTION_BEGIN_DT":"08/23/2004","INSPECTION_END_DT":"08/31/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"35.5","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"725859","EVENT_NO":"4127923","INSPECTION_BEGIN_DT":"08/09/2004","INSPECTION_END_DT":"08/17/2004","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2004-08-09"},{"SOURCE_ROW_NUMBER":"731496","EVENT_NO":"4153117","INSPECTION_BEGIN_DT":"07/01/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"125","SUM_TOTAL_ON_SITE_HOURS":"39.25","sourceDate":"2004-07-01"},{"SOURCE_ROW_NUMBER":"174287","EVENT_NO":"4153037","INSPECTION_BEGIN_DT":"06/07/2004","INSPECTION_END_DT":"06/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"83.5","SUM_TOTAL_ON_SITE_HOURS":"45","sourceDate":"2004-06-07"},{"SOURCE_ROW_NUMBER":"195255","EVENT_NO":"4144927","INSPECTION_BEGIN_DT":"03/03/2004","INSPECTION_END_DT":"03/03/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2004-03-03"},{"SOURCE_ROW_NUMBER":"390629","EVENT_NO":"4144581","INSPECTION_BEGIN_DT":"12/11/2003","INSPECTION_END_DT":"12/18/2003","ACTIVITY_CODE":"CBA","ACTIVITY":"ELECTRICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"19.5","sourceDate":"2003-12-11"},{"SOURCE_ROW_NUMBER":"771461","EVENT_NO":"4147208","INSPECTION_BEGIN_DT":"10/28/2003","INSPECTION_END_DT":"11/04/2003","ACTIVITY_CODE":"CBD","ACTIVITY":"RESPIRABLE DUST MONITORING INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"26","SUM_TOTAL_ON_SITE_HOURS":"15.25","sourceDate":"2003-10-28"},{"SOURCE_ROW_NUMBER":"770291","EVENT_NO":"4144912","INSPECTION_BEGIN_DT":"10/03/2003","INSPECTION_END_DT":"12/19/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"49","SUM_TOTAL_ON_SITE_HOURS":"27","sourceDate":"2003-10-03"},{"SOURCE_ROW_NUMBER":"1005426","EVENT_NO":"4144739","INSPECTION_BEGIN_DT":"09/15/2003","INSPECTION_END_DT":"09/17/2003","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2003-09-15"},{"SOURCE_ROW_NUMBER":"789488","EVENT_NO":"4144907","INSPECTION_BEGIN_DT":"09/09/2003","INSPECTION_END_DT":"09/30/2003","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"8.25","sourceDate":"2003-09-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q4":{"hours":0,"employees":0,"production":0},"2004-Q3":{"hours":0,"employees":0,"production":0},"2004-Q2":{"hours":10,"employees":1,"production":0},"2004-Q1":{"hours":0,"employees":0,"production":0},"2003-Q4":{"hours":1675,"employees":5,"production":5963},"2003-Q3":{"hours":3632,"employees":11,"production":6056},"2003-Q2":{"hours":4407,"employees":11,"production":4050},"2003-Q1":{"hours":7957,"employees":14,"production":12777},"2002-Q4":{"hours":5878,"employees":11,"production":15643},"2002-Q3":{"hours":4774,"employees":13,"production":11486},"2002-Q2":{"hours":5321,"employees":12,"production":5591},"2002-Q1":{"hours":7082,"employees":16,"production":8177}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":9241,"employees":9,"production":2104},"2002":{"hours":23055,"employees":13,"production":40897},"2003":{"hours":17671,"employees":11,"production":28846},"2004":{"hours":10,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":11,"firstDate":"2002-08-12","lastDate":"2003-09-10","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":664,"pelDoseTotal":480},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"198223","EVENT_NO":"4144906","SURVEY_DATE":"09/10/2003","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"1","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2003-09-10"},{"SOURCE_ROW_NUMBER":"198228","EVENT_NO":"4147039","SURVEY_DATE":"08/21/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"83","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2003-08-21"},{"SOURCE_ROW_NUMBER":"198227","EVENT_NO":"4147039","SURVEY_DATE":"08/21/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"102","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2003-08-21"},{"SOURCE_ROW_NUMBER":"198226","EVENT_NO":"4147039","SURVEY_DATE":"08/21/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"070","ACT_DOSE_85":"122","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2003-08-21"},{"SOURCE_ROW_NUMBER":"198225","EVENT_NO":"4147039","SURVEY_DATE":"08/21/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"053","ACT_DOSE_85":"63","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2003-08-21"},{"SOURCE_ROW_NUMBER":"198224","EVENT_NO":"4147039","SURVEY_DATE":"08/21/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"067","ACT_DOSE_85":"96","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2003-08-21"},{"SOURCE_ROW_NUMBER":"198222","EVENT_NO":"4138610","SURVEY_DATE":"08/12/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"043","ACT_DOSE_85":"47","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"198221","EVENT_NO":"4138610","SURVEY_DATE":"08/12/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"37","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"198220","EVENT_NO":"4138610","SURVEY_DATE":"08/12/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"45","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"198219","EVENT_NO":"4138610","SURVEY_DATE":"08/12/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2002-08-12"},{"SOURCE_ROW_NUMBER":"198218","EVENT_NO":"4138610","SURVEY_DATE":"08/12/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"66","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2002-08-12"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":15,"firstDate":"2001-11-21","lastDate":"2003-09-04","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":28.5,"validSamples":13,"quartzPctTotal":181.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"80758","CASSETTE_NO":"50687915","SAMPLE_DT":"09/04/2003","QUARTZ_PCT":"28.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-09-04"},{"SOURCE_ROW_NUMBER":"66672","CASSETTE_NO":"50689405","SAMPLE_DT":"08/20/2003","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-20"},{"SOURCE_ROW_NUMBER":"90182","CASSETTE_NO":"57465854","SAMPLE_DT":"08/04/2003","QUARTZ_PCT":"20.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-04"},{"SOURCE_ROW_NUMBER":"105288","CASSETTE_NO":"50693100","SAMPLE_DT":"07/11/2003","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2003-07-11"},{"SOURCE_ROW_NUMBER":"120455","CASSETTE_NO":"50693086","SAMPLE_DT":"06/23/2003","QUARTZ_PCT":"21.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-06-23"},{"SOURCE_ROW_NUMBER":"150222","CASSETTE_NO":"57421262","SAMPLE_DT":"08/02/2002","QUARTZ_PCT":"13.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-08-02"},{"SOURCE_ROW_NUMBER":"61501","CASSETTE_NO":"57421131","SAMPLE_DT":"08/02/2002","QUARTZ_PCT":"14.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-08-02"},{"SOURCE_ROW_NUMBER":"62403","CASSETTE_NO":"57409532","SAMPLE_DT":"03/28/2002","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-28"},{"SOURCE_ROW_NUMBER":"32472","CASSETTE_NO":"57409535","SAMPLE_DT":"03/28/2002","QUARTZ_PCT":"13.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-28"},{"SOURCE_ROW_NUMBER":"161802","CASSETTE_NO":"50639557","SAMPLE_DT":"02/12/2002","QUARTZ_PCT":"09.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"69728","CASSETTE_NO":"50639573","SAMPLE_DT":"02/12/2002","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"159743","CASSETTE_NO":"57409928","SAMPLE_DT":"01/23/2002","QUARTZ_PCT":"09.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-23"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":214,"firstDate":"2001-11-07","lastDate":"2004-08-31","metrics":{"ss":90,"amountDue":46721,"contested":19,"amountPaid":0,"recentRows":0,"section104d":14,"unterminated":2,"proposedPenalty":48132},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2334498","VIOLATION_NO":"7337850","VIOLATION_ISSUE_DT":"08/31/2004","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/31/2004","PROPOSED_PENALTY":"2200","AMOUNT_DUE":"2200","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"2334497","VIOLATION_NO":"7337849","VIOLATION_ISSUE_DT":"08/31/2004","SIG_SUB":"Y","PART_SECTION":"77.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/31/2004","PROPOSED_PENALTY":"2200","AMOUNT_DUE":"2200","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"2334496","VIOLATION_NO":"7337848","VIOLATION_ISSUE_DT":"08/31/2004","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/31/2004","PROPOSED_PENALTY":"2200","AMOUNT_DUE":"2200","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"2334495","VIOLATION_NO":"7337847","VIOLATION_ISSUE_DT":"08/31/2004","SIG_SUB":"Y","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/31/2004","PROPOSED_PENALTY":"875","AMOUNT_DUE":"875","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"2334494","VIOLATION_NO":"7337846","VIOLATION_ISSUE_DT":"08/31/2004","SIG_SUB":"Y","SECTION_OF_ACT":"107(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"08/31/2004","CONTESTED_IND":"N","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"2334493","VIOLATION_NO":"7337845","VIOLATION_ISSUE_DT":"08/31/2004","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"08/31/2004","PROPOSED_PENALTY":"525","AMOUNT_DUE":"525","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-31"},{"SOURCE_ROW_NUMBER":"2334543","VIOLATION_NO":"3353788","VIOLATION_ISSUE_DT":"08/25/2004","PART_SECTION":"75.360(a)(1)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"09/20/2004","CONTESTED_IND":"N","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"2334542","VIOLATION_NO":"3353787","VIOLATION_ISSUE_DT":"08/25/2004","SIG_SUB":"N","PART_SECTION":"75.1715","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"5","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/20/2004","PROPOSED_PENALTY":"750","AMOUNT_DUE":"750","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"2334541","VIOLATION_NO":"3353786","VIOLATION_ISSUE_DT":"08/25/2004","SIG_SUB":"N","PART_SECTION":"75.800-4","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"6","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/22/2004","PROPOSED_PENALTY":"1000","AMOUNT_DUE":"1000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"2334540","VIOLATION_NO":"3353785","VIOLATION_ISSUE_DT":"08/25/2004","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"6","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/30/2004","PROPOSED_PENALTY":"1000","AMOUNT_DUE":"1000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"2334539","VIOLATION_NO":"3353784","VIOLATION_ISSUE_DT":"08/25/2004","SIG_SUB":"N","PART_SECTION":"75.900-4","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"6","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/30/2004","PROPOSED_PENALTY":"1000","AMOUNT_DUE":"1000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-25"},{"SOURCE_ROW_NUMBER":"2334538","VIOLATION_NO":"3353783","VIOLATION_ISSUE_DT":"08/25/2004","SIG_SUB":"N","PART_SECTION":"75.312(g)(1)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"6","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/20/2004","PROPOSED_PENALTY":"1000","AMOUNT_DUE":"1000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-08-25"}]}],"safety":{"href":"/api/v1/mines/4405331/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4405331/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","heading":"Electric wiring and equipment; installation and maintenance.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.516","part":"77","subchapter":"O","subpart":"F","id":"77.516","citation":"30 CFR 77.516","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Identification check system.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1715","part":"75","subchapter":"O","subpart":"R","id":"75.1715","citation":"30 CFR 75.1715","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.800-4","heading":"Testing, examination, and maintenance of circuit breakers; record.","id":"75.800-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.800-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"I","subpartHeading":"Subpart I—Underground High-Voltage Distribution","text":"(a) Recordkeeping. The operator shall make a record of each test, examination, repair, or adjustment of all circuit breakers protecting high-voltage circuits which enter any underground area of the mine.\n\n(b) Record security. These records shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(c) Retention and access. These records shall be retained at a surface location at the mine for at least one year and shall be made available to authorized representatives of the Secretary, the representative of miners, and other interested persons.\n\n[64 FR 43287, Aug. 10, 1999]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; record.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.900-4","part":"75","subchapter":"O","subpart":"J","id":"75.900-4","citation":"30 CFR 75.900-4","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4405331","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}