{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4405210","name":"#44","status":"Abandoned and Sealed","status_date":"2006-01-04","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Dickenson","nearest_town":"Nora","operator_id":"P24661","operator_name":"Gbl Enterprises Inc","controller_id":"C02467","controller_name":"Arlie J  Lambert; Dennis B  Sutherland","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.044444,"longitude":-82.305555},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":744},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4405210","name":"#44"},"operator":{"type":"operator","id":"P24661","name":"Gbl Enterprises Inc"},"controller":{"type":"controller","id":"C02467","name":"Arlie J  Lambert; Dennis B  Sutherland"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24661","name":"Gbl Enterprises Inc"},"object":{"type":"mine","id":"4405210","name":"#44"},"validFrom":"1979-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405210|P24661|1979-04-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02467","name":"Arlie J  Lambert et al"},"object":{"type":"mine","id":"4405210","name":"#44"},"validFrom":"1979-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405210|C02467|1979-04-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02467","name":"Arlie J  Lambert et al"},"object":{"type":"operator","id":"P24661","name":"Gbl Enterprises Inc"},"validFrom":"1979-04-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4405210","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405210|P24661|1979-04-01|C02467|1979-04-01|58580"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02467","name":"Dennis B  Sutherland et al"},"object":{"type":"operator","id":"P24661","name":"Gbl Enterprises Inc"},"validFrom":"1979-04-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4405210","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4405210|P24661|1979-04-01|C02467|1979-04-01|58581"}}],"coverage":{"historyRecords":2,"edgeCount":4,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":7,"firstDate":"2000-02-02","lastDate":"2004-05-26","metrics":{"daysLost":370,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":5,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"136499","DOCUMENT_NO":"220041590072","ACCIDENT_DT":"05/26/2004","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EMPLOYEE WAS USING A SLATE BAR TO PRY SHIMS FROM TRACK, BAR SLIPPED HURTING EE'S HAND & WRIST.","sourceDate":"2004-05-26"},{"SOURCE_ROW_NUMBER":"20481","DOCUMENT_NO":"220032330030","ACCIDENT_DT":"08/08/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"EMPLOYEE WAS MOVING THE MINER CABLE AND FELT PAIN IN HIS BACK.","sourceDate":"2003-08-08"},{"SOURCE_ROW_NUMBER":"33399","DOCUMENT_NO":"220031690024","ACCIDENT_DT":"06/04/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"270","NARRATIVE":"EE WAS RIDING A BATTERY POWERED PERSONNEL CARRIER WHICH RAN OVER A HOLE, CAUSING EE TO BOUNCE UP, JARRING HIS BACK AND LEG.","sourceDate":"2003-06-04"},{"SOURCE_ROW_NUMBER":"222629","DOCUMENT_NO":"220023650001","ACCIDENT_DT":"12/17/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"69","NARRATIVE":"EE WAS LIFTING A VALVE BLOCK OUT OF THE ROOF BOLTER FOR REPAIR AND FELT PAIN IN LOWER BACK.","sourceDate":"2002-12-17"},{"SOURCE_ROW_NUMBER":"226965","DOCUMENT_NO":"220023460008","ACCIDENT_DT":"12/04/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL #2 ENTRY, 1 BREAK INBY SPAD 3440. 20' X 20' X 4' FALL, AREA TIMBERS AND CRIBBED OFF. AREA MARKED OFF AND LEFT.","sourceDate":"2002-12-04"},{"SOURCE_ROW_NUMBER":"274199","DOCUMENT_NO":"220010230037","ACCIDENT_DT":"01/15/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"17","NARRATIVE":"EE WAS OPERATING R.B. BOLTER WRENCH STUCK ON BOLT. WHEN HEAD WAS LOWERED THE WRENCH FELL AND HIT EE ON THE LEFT INDEX FINGER.","sourceDate":"2001-01-15"},{"SOURCE_ROW_NUMBER":"226964","DOCUMENT_NO":"220000410013","ACCIDENT_DT":"02/02/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"WHILE OPERATING THE ROOF BOLTER THE PINNER WRENCH HIT EE IN THE MOUTH.","sourceDate":"2000-02-02"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-01-04","lastDate":"2006-01-04","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":37,"firstDate":"2000-03-17","lastDate":"2005-02-28","metrics":{"ss":5,"delinquent":37,"recentRows":0,"paidPenalty":2292,"proposedPenalty":2292,"currentAssessment":2292},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"922059","VIOLATION_NO":"7343310","ISSUE_DT":"02/28/2005","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-02-28"},{"SOURCE_ROW_NUMBER":"922058","VIOLATION_NO":"7343308","ISSUE_DT":"02/22/2005","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-02-22"},{"SOURCE_ROW_NUMBER":"922057","VIOLATION_NO":"7343307","ISSUE_DT":"02/22/2005","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-02-22"},{"SOURCE_ROW_NUMBER":"882599","VIOLATION_NO":"7342071","ISSUE_DT":"12/29/2004","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"921409","VIOLATION_NO":"7342845","ISSUE_DT":"11/23/2004","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"921408","VIOLATION_NO":"7342844","ISSUE_DT":"11/23/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"921407","VIOLATION_NO":"7342843","ISSUE_DT":"11/23/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"921406","VIOLATION_NO":"7342842","ISSUE_DT":"11/23/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"921356","VIOLATION_NO":"7338820","ISSUE_DT":"08/23/2004","CFR_STANDARD_CD":"75.320(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"921315","VIOLATION_NO":"7338802","ISSUE_DT":"06/07/2004","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-07"},{"SOURCE_ROW_NUMBER":"878647","VIOLATION_NO":"9870330","ISSUE_DT":"05/24/2004","CFR_STANDARD_CD":"70.208(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-05-24"},{"SOURCE_ROW_NUMBER":"921314","VIOLATION_NO":"7336911","ISSUE_DT":"04/13/2004","CFR_STANDARD_CD":"75.1107-4(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-04-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":455,"firstDate":"2000-01-10","lastDate":"2005-03-22","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":30,"validSamples":425,"maxConcentration":3.12,"concentrationTotal":137.518},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1580583","CASS_NUM":"57554829","SMP_TAKEN_DT":"3/22/2005","CONC":".329","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-22"},{"SOURCE_ROW_NUMBER":"1186167","CASS_NUM":"57554868","SMP_TAKEN_DT":"3/22/2005","CONC":".139","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-22"},{"SOURCE_ROW_NUMBER":"1050073","CASS_NUM":"57554909","SMP_TAKEN_DT":"3/22/2005","CONC":".269","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-22"},{"SOURCE_ROW_NUMBER":"445434","CASS_NUM":"57554944","SMP_TAKEN_DT":"3/22/2005","CONC":".114","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-22"},{"SOURCE_ROW_NUMBER":"189844","CASS_NUM":"57554831","SMP_TAKEN_DT":"3/22/2005","CONC":".529","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-03-22"},{"SOURCE_ROW_NUMBER":"133514","CASS_NUM":"50688569","SMP_TAKEN_DT":"2/4/2005","CONC":".428","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-04"},{"SOURCE_ROW_NUMBER":"687635","CASS_NUM":"50679038","SMP_TAKEN_DT":"2/3/2005","CONC":".437","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-03"},{"SOURCE_ROW_NUMBER":"1160482","CASS_NUM":"50688528","SMP_TAKEN_DT":"2/2/2005","CONC":".323","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-02-02"},{"SOURCE_ROW_NUMBER":"1439383","CASS_NUM":"50688542","SMP_TAKEN_DT":"1/26/2005","CONC":".309","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-26"},{"SOURCE_ROW_NUMBER":"1576265","CASS_NUM":"50679043","SMP_TAKEN_DT":"1/25/2005","CONC":"1.29","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-25"},{"SOURCE_ROW_NUMBER":"890631","CASS_NUM":"50678995","SMP_TAKEN_DT":"1/24/2005","CONC":".178","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-24"},{"SOURCE_ROW_NUMBER":"307739","CASS_NUM":"50688538","SMP_TAKEN_DT":"1/21/2005","CONC":".153","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-01-21"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1979-04-01","lastDate":"1979-04-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":90,"firstDate":"2000-01-11","lastDate":"2005-10-17","metrics":{"inspectors":111,"recentRows":0,"onSiteHours":994.75,"inspectionHours":1835.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"550890","EVENT_NO":"4141079","INSPECTION_BEGIN_DT":"10/17/2005","INSPECTION_END_DT":"12/29/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2005-10-17"},{"SOURCE_ROW_NUMBER":"513698","EVENT_NO":"4141073","INSPECTION_BEGIN_DT":"09/28/2005","INSPECTION_END_DT":"09/28/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-09-28"},{"SOURCE_ROW_NUMBER":"602522","EVENT_NO":"4155870","INSPECTION_BEGIN_DT":"07/11/2005","INSPECTION_END_DT":"09/28/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2005-07-11"},{"SOURCE_ROW_NUMBER":"810334","EVENT_NO":"4155857","INSPECTION_BEGIN_DT":"04/04/2005","INSPECTION_END_DT":"06/28/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2005-04-04"},{"SOURCE_ROW_NUMBER":"537442","EVENT_NO":"4128924","INSPECTION_BEGIN_DT":"03/16/2005","INSPECTION_END_DT":"03/23/2005","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2005-03-16"},{"SOURCE_ROW_NUMBER":"939016","EVENT_NO":"4155847","INSPECTION_BEGIN_DT":"01/05/2005","INSPECTION_END_DT":"03/30/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"90","SUM_TOTAL_ON_SITE_HOURS":"49","sourceDate":"2005-01-05"},{"SOURCE_ROW_NUMBER":"252760","EVENT_NO":"4130219","INSPECTION_BEGIN_DT":"12/29/2004","INSPECTION_END_DT":"01/03/2005","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"33.5","SUM_TOTAL_ON_SITE_HOURS":"15","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"703250","EVENT_NO":"4127977","INSPECTION_BEGIN_DT":"11/03/2004","INSPECTION_END_DT":"11/04/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2004-11-03"},{"SOURCE_ROW_NUMBER":"1001981","EVENT_NO":"4155682","INSPECTION_BEGIN_DT":"10/04/2004","INSPECTION_END_DT":"12/08/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"47","SUM_TOTAL_ON_SITE_HOURS":"25.5","sourceDate":"2004-10-04"},{"SOURCE_ROW_NUMBER":"395800","EVENT_NO":"4127965","INSPECTION_BEGIN_DT":"09/21/2004","INSPECTION_END_DT":"09/21/2004","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2004-09-21"},{"SOURCE_ROW_NUMBER":"1137481","EVENT_NO":"4155673","INSPECTION_BEGIN_DT":"08/17/2004","INSPECTION_END_DT":"08/19/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2004-08-17"},{"SOURCE_ROW_NUMBER":"1046255","EVENT_NO":"4155674","INSPECTION_BEGIN_DT":"08/17/2004","INSPECTION_END_DT":"08/31/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2004-08-17"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":63,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q1":{"hours":0,"employees":0,"production":0},"2005-Q4":{"hours":85,"employees":1,"production":0},"2005-Q3":{"hours":120,"employees":1,"production":0},"2005-Q2":{"hours":480,"employees":8,"production":1140},"2005-Q1":{"hours":4623,"employees":9,"production":7260},"2004-Q4":{"hours":5665,"employees":10,"production":13043},"2004-Q3":{"hours":5808,"employees":10,"production":10920},"2004-Q2":{"hours":6355,"employees":11,"production":16231},"2004-Q1":{"hours":6439,"employees":11,"production":16366},"2003-Q4":{"hours":6410,"employees":11,"production":13171},"2003-Q3":{"hours":6573,"employees":11,"production":13929},"2003-Q2":{"hours":6732,"employees":11,"production":21517}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":23681,"employees":11,"production":78764},"2001":{"hours":26376,"employees":12,"production":78936},"2002":{"hours":23658,"employees":12,"production":52043},"2003":{"hours":26444,"employees":11,"production":62529},"2004":{"hours":24267,"employees":11,"production":56560},"2005":{"hours":5308,"employees":6,"production":8400}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":24,"firstDate":"2000-01-24","lastDate":"2004-08-18","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":1366,"pelDoseTotal":940},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"197473","EVENT_NO":"4155673","SURVEY_DATE":"08/18/2004","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"15","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2004-08-18"},{"SOURCE_ROW_NUMBER":"197472","EVENT_NO":"4155664","SURVEY_DATE":"06/09/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"057","ACT_DOSE_85":"46","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"197471","EVENT_NO":"4155664","SURVEY_DATE":"06/09/2004","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"057","ACT_DOSE_85":"32","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"197470","EVENT_NO":"4155664","SURVEY_DATE":"06/09/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"69","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"197469","EVENT_NO":"4155664","SURVEY_DATE":"06/09/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"86","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"197468","EVENT_NO":"4155664","SURVEY_DATE":"06/09/2004","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"057","ACT_DOSE_85":"56","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"197467","EVENT_NO":"4155617","SURVEY_DATE":"07/15/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"31","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2003-07-15"},{"SOURCE_ROW_NUMBER":"197466","EVENT_NO":"4155617","SURVEY_DATE":"07/15/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"44","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2003-07-15"},{"SOURCE_ROW_NUMBER":"197465","EVENT_NO":"4155617","SURVEY_DATE":"07/15/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"31","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2003-07-15"},{"SOURCE_ROW_NUMBER":"197464","EVENT_NO":"4155617","SURVEY_DATE":"07/15/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"96","PEL_DOSE_90":"70","SURVEY_TYPE":"I","sourceDate":"2003-07-15"},{"SOURCE_ROW_NUMBER":"197463","EVENT_NO":"4155617","SURVEY_DATE":"07/15/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"45","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2003-07-15"},{"SOURCE_ROW_NUMBER":"197462","EVENT_NO":"4155617","SURVEY_DATE":"07/15/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"53","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2003-07-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":15,"firstDate":"2000-02-08","lastDate":"2004-10-04","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":11.4,"validSamples":14,"quartzPctTotal":91.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"150868","CASSETTE_NO":"57554583","SAMPLE_DT":"10/04/2004","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-10-04"},{"SOURCE_ROW_NUMBER":"63883","CASSETTE_NO":"57543243","SAMPLE_DT":"07/21/2004","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-07-21"},{"SOURCE_ROW_NUMBER":"61525","CASSETTE_NO":"50688515","SAMPLE_DT":"06/08/2004","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"101314","CASSETTE_NO":"57552945","SAMPLE_DT":"05/17/2004","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-17"},{"SOURCE_ROW_NUMBER":"9680","CASSETTE_NO":"57553151","SAMPLE_DT":"05/17/2004","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-17"},{"SOURCE_ROW_NUMBER":"165431","CASSETTE_NO":"57530603","SAMPLE_DT":"02/04/2004","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"117866","CASSETTE_NO":"57518901","SAMPLE_DT":"08/13/2003","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-13"},{"SOURCE_ROW_NUMBER":"47611","CASSETTE_NO":"57518498","SAMPLE_DT":"07/17/2003","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-07-17"},{"SOURCE_ROW_NUMBER":"137439","CASSETTE_NO":"57409429","SAMPLE_DT":"04/03/2002","QUARTZ_PCT":"07.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-04-03"},{"SOURCE_ROW_NUMBER":"57718","CASSETTE_NO":"57408857","SAMPLE_DT":"02/12/2002","QUARTZ_PCT":"08.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"17889","CASSETTE_NO":"57408961","SAMPLE_DT":"02/12/2002","QUARTZ_PCT":"07.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"30152","CASSETTE_NO":"57397425","SAMPLE_DT":"12/03/2001","QUARTZ_PCT":"11.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-03"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":37,"firstDate":"2000-03-17","lastDate":"2005-02-28","metrics":{"ss":5,"amountDue":2292,"contested":0,"amountPaid":2292,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2292},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2331970","VIOLATION_NO":"7343310","VIOLATION_ISSUE_DT":"02/28/2005","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/28/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-02-28"},{"SOURCE_ROW_NUMBER":"2331969","VIOLATION_NO":"7343308","VIOLATION_ISSUE_DT":"02/22/2005","SIG_SUB":"N","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/22/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-02-22"},{"SOURCE_ROW_NUMBER":"2331968","VIOLATION_NO":"7343307","VIOLATION_ISSUE_DT":"02/22/2005","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/22/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-02-22"},{"SOURCE_ROW_NUMBER":"2331998","VIOLATION_NO":"7342071","VIOLATION_ISSUE_DT":"12/29/2004","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/03/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"2331990","VIOLATION_NO":"7342845","VIOLATION_ISSUE_DT":"11/23/2004","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/23/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"2331989","VIOLATION_NO":"7342844","VIOLATION_ISSUE_DT":"11/23/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"2331988","VIOLATION_NO":"7342843","VIOLATION_ISSUE_DT":"11/23/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"2331987","VIOLATION_NO":"7342842","VIOLATION_ISSUE_DT":"11/23/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-11-23"},{"SOURCE_ROW_NUMBER":"2331984","VIOLATION_NO":"7338820","VIOLATION_ISSUE_DT":"08/23/2004","SIG_SUB":"N","PART_SECTION":"75.320(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/23/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"2331976","VIOLATION_NO":"7338802","VIOLATION_ISSUE_DT":"06/07/2004","SIG_SUB":"N","PART_SECTION":"77.205(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-07"},{"SOURCE_ROW_NUMBER":"2331981","VIOLATION_NO":"9870330","VIOLATION_ISSUE_DT":"05/24/2004","SIG_SUB":"N","PART_SECTION":"70.208(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/18/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-05-24"},{"SOURCE_ROW_NUMBER":"2331975","VIOLATION_NO":"7336911","VIOLATION_ISSUE_DT":"04/13/2004","SIG_SUB":"N","PART_SECTION":"75.1107-4(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/20/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-04-13"}]}],"safety":{"href":"/api/v1/mines/4405210/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4405210/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","heading":"Air quality detectors and measurement devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.320","part":"75","subchapter":"O","subpart":"D","id":"75.320","citation":"30 CFR 75.320","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","heading":"Quarterly sampling; mechanized mining units.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.208","part":"70","subchapter":"O","subpart":"C","id":"70.208","citation":"30 CFR 70.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4405210","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}