{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4403932","name":"Miles Branch Mine","status":"Abandoned and Sealed","status_date":"2011-03-09","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Tazewell","nearest_town":"BISHOP","operator_id":"P00812","operator_name":"Consolidation Coal Company","controller_id":"C13408","controller_name":"Robert E  Murray","district":"C05","office":"Vansant VA Field Office","employees":0,"latitude":37.188888,"longitude":-81.636388},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2833},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"operator":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"controller":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00129","name":"Consolidation Coal Co & Inland Steel Co"},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|C00129|1950-01-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"1950-01-01","validTo":"2013-12-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|C00692|1950-01-01|2013-12-04"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00263","name":"Bishop Coal Company"},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"1975-01-01","validTo":"2002-04-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|P00263|1975-01-01|2002-04-17"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00129","name":"Consolidation Coal Co & Inland Steel Co"},"object":{"type":"operator","id":"P00263","name":"Bishop Coal Company"},"validFrom":"1975-01-01","validTo":"2002-04-17","current":false,"derived":true,"evidenceMineId":"4403932","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|P00263|1975-01-01|C00129|1950-01-01|44389"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14809","name":"Richard F  Baugh"},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"1996-10-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|C14809|1996-10-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23623","name":"Corbin Collieries, Inc."},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"2002-04-18","validTo":"2003-01-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|P23623|2002-04-18|2003-01-06"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14809","name":"Richard F  Baugh"},"object":{"type":"operator","id":"P23623","name":"Corbin Collieries, Inc."},"validFrom":"2002-04-18","validTo":"2003-01-06","current":false,"derived":true,"evidenceMineId":"4403932","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|P23623|2002-04-18|C14809|1996-10-01|93939"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051001","name":"BC Mining, Inc."},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"2003-01-07","validTo":"2003-04-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|0051001|2003-01-07|2003-04-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11941","name":"Ronald  Combs et al"},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"2003-01-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|C11941|2003-01-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11941","name":"Ronald  Combs et al"},"object":{"type":"operator","id":"0051001","name":"BC Mining, Inc."},"validFrom":"2003-01-07","validTo":"2003-04-30","current":false,"derived":true,"evidenceMineId":"4403932","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|0051001|2003-01-07|C11941|2003-01-07|85760"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"2003-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|P00812|2003-05-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"validFrom":"2003-05-01","validTo":"2013-12-04","current":false,"derived":true,"evidenceMineId":"4403932","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|P00812|2003-05-01|C00692|1950-01-01|49116"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"4403932","name":"Miles Branch Mine"},"validFrom":"2013-12-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|C13408|2013-12-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"P00812","name":"Consolidation Coal Company"},"validFrom":"2013-12-05","validTo":null,"current":true,"derived":true,"evidenceMineId":"4403932","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4403932|P00812|2003-05-01|C13408|2013-12-05|89689"}}],"coverage":{"historyRecords":5,"edgeCount":14,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":57,"firstDate":"2003-06-05","lastDate":"2014-09-05","metrics":{"daysLost":1526,"injuries":22,"fatalities":0,"recentRows":0,"restrictedDays":91,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"175315","DOCUMENT_NO":"220142510001","ACCIDENT_DT":"09/05/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Cigarette lighter blew up in right hand","sourceDate":"2014-09-05"},{"SOURCE_ROW_NUMBER":"16172","DOCUMENT_NO":"220092570046","ACCIDENT_DT":"08/13/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"224","NARRATIVE":"Tearing out a mine fan, the top half of the shroud had been unbolted from the lower half with several bolts left in the conndu without nuts. As one piece was being lifted by a 15ton crane ee stepped onto the top of the shroud closest to the blade. The shroud moved ee jumped off and the shroud rolled onto him pinning him under it.","sourceDate":"2009-08-13"},{"SOURCE_ROW_NUMBER":"132095","DOCUMENT_NO":"220083010046","ACCIDENT_DT":"10/10/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was in process of picking up a timber and turned to place on a stack of timbers and felt pain in lower back. Employee had MRI and was diagnosed with lumbar sprain/strain on 10/21/2008.","sourceDate":"2008-10-10"},{"SOURCE_ROW_NUMBER":"97711","DOCUMENT_NO":"220082760053","ACCIDENT_DT":"09/25/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unintentional roof fall occurred in the # 1 entry of 6-Mains starting at SS# 3907 extending to SS# 3847 and continuing inby SS# 3847 into the #4 entry of 6-Left panel for approximately 80'. The fall dimensions were approximately 18' w x 6' h x 260' long.","sourceDate":"2008-09-25"},{"SOURCE_ROW_NUMBER":"231233","DOCUMENT_NO":"220082380056","ACCIDENT_DT":"08/14/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unintentional roof fall occurred at ss# 4215 in the mains bleeder #4 entry. The fall dimensions were approx. 35;L x 18;W x 6'H.","sourceDate":"2008-08-14"},{"SOURCE_ROW_NUMBER":"158115","DOCUMENT_NO":"220082320045","ACCIDENT_DT":"08/11/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"82","NARRATIVE":"EE was in process of setting turn timbers in the #13 entry of Mains section for the right barrier lift, when two sections of roof broke loose from the roof, measuring from 0-2\" thick and 45\" X 28\" and 45\" X 27\". The roof fell out from around the roof bolts, striking him on back of the head, middle of back, top left hand and left elbow.","sourceDate":"2008-08-11"},{"SOURCE_ROW_NUMBER":"3351","DOCUMENT_NO":"220081360048","ACCIDENT_DT":"05/09/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was n the process of extending line curtain when a section of roof fell measuring 7.5'L x 6'W x 0-14\" thick from the unbolted face and extending approximately 16\" past last row of bolts to where he was standing under a permanently supported area striking him across both legs resulting in fracture to left big toe and tailbone.","sourceDate":"2008-05-09"},{"SOURCE_ROW_NUMBER":"84977","DOCUMENT_NO":"220080160007","ACCIDENT_DT":"01/04/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"172","NARRATIVE":"He was shoveling snow out of truck bed.  Fell down in the truck bed.","sourceDate":"2008-01-04"},{"SOURCE_ROW_NUMBER":"3350","DOCUMENT_NO":"220073230077","ACCIDENT_DT":"11/06/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unintentional roof fall occurred approx one crosscut inby SS# 3779 in the #4 entry of the Mains section. The fall dimensions were approx 20'W x 45'L x 6'H.","sourceDate":"2007-11-06"},{"SOURCE_ROW_NUMBER":"179655","DOCUMENT_NO":"220080150059","ACCIDENT_DT":"10/29/2007","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"115","NARRATIVE":"Employee was operating unihauler while pushing disabled scoop on the surface, when the hauler bucket was raised up approximately one and one half feet and dropped back down to the ground causing him to be shaken in deck. He complained of pain in back, neck and right shoulder. He started missing work on 12/27/07 and medical diagnosis not received until 1/8/08.","sourceDate":"2007-10-29"},{"SOURCE_ROW_NUMBER":"132094","DOCUMENT_NO":"220073030036","ACCIDENT_DT":"10/24/2007","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"IGNITION OR EXPLOSION OF GAS OR DUST","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A methane ignition occurred on Mains section in the face of #3 entry while mining with Joy 14cm15 continuous miner approximately 136' inby SS #4101.","sourceDate":"2007-10-24"},{"SOURCE_ROW_NUMBER":"265662","DOCUMENT_NO":"220073020066","ACCIDENT_DT":"10/16/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"163","NARRATIVE":"EE was in process of tramming miner out of #2 entry on 6-Left when a bucket started to fall off miner. He stopped miner and reached to grab bucket and inadvertenly contacted tram controls on remote box, causing the miner to move partially, catching his right hip between the cable stand off on miner and coal rib.","sourceDate":"2007-10-16"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2011-03-09","lastDate":"2011-03-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":506,"firstDate":"2002-12-03","lastDate":"2009-09-25","metrics":{"ss":205,"delinquent":486,"recentRows":0,"paidPenalty":129384,"proposedPenalty":169283,"currentAssessment":131375},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"906460","VIOLATION_NO":"8168783","ISSUE_DT":"09/25/2009","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3689.00","CURRENT_ASSESSMENT_AMT":"3689.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-09-25"},{"SOURCE_ROW_NUMBER":"906459","VIOLATION_NO":"8168782","ISSUE_DT":"09/25/2009","CFR_STANDARD_CD":"77.1710(g)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3689.00","CURRENT_ASSESSMENT_AMT":"1657.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-09-25"},{"SOURCE_ROW_NUMBER":"1336767","VIOLATION_NO":"6640238","ISSUE_DT":"11/06/2008","CFR_STANDARD_CD":"75.364","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-06"},{"SOURCE_ROW_NUMBER":"1336775","VIOLATION_NO":"6641186","ISSUE_DT":"10/31/2008","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"1336774","VIOLATION_NO":"6641185","ISSUE_DT":"10/31/2008","CFR_STANDARD_CD":"75.360(b)(3)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"1336773","VIOLATION_NO":"6641184","ISSUE_DT":"10/31/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"807.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"1336772","VIOLATION_NO":"6641183","ISSUE_DT":"10/31/2008","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"1336771","VIOLATION_NO":"6640874","ISSUE_DT":"10/28/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"807.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"1336770","VIOLATION_NO":"6640873","ISSUE_DT":"10/28/2008","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1203.00","CURRENT_ASSESSMENT_AMT":"540.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"1336769","VIOLATION_NO":"6640872","ISSUE_DT":"10/28/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"1336768","VIOLATION_NO":"6640871","ISSUE_DT":"10/28/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"1336735","VIOLATION_NO":"7317936","ISSUE_DT":"09/04/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"191.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":104,"firstDate":"2004-11-24","lastDate":"2011-03-23","metrics":{"appeals":0,"decisions":104,"recentRows":0,"decisionPenalty":57662,"originalPenalty":99586},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"213670","VIOLATION_NO":"6633658","DOCKET_NO":"VA 2008-194","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1795.00","DECISION_PENALTY_AMT":"1256.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"19701","VIOLATION_NO":"6633690","DOCKET_NO":"VA 2008-194","DECISION_DT":"03/23/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"778.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2011-03-23"},{"SOURCE_ROW_NUMBER":"232500","VIOLATION_NO":"7317936","DOCKET_NO":"VA 2009-91","DECISION_DT":"09/22/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"191.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-09-22"},{"SOURCE_ROW_NUMBER":"229214","VIOLATION_NO":"6640927","DOCKET_NO":"VA 2009-20","DECISION_DT":"09/22/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-09-22"},{"SOURCE_ROW_NUMBER":"267696","VIOLATION_NO":"8168783","DOCKET_NO":"VA 2010-200","DECISION_DT":"09/09/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"3689.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2010-09-09"},{"SOURCE_ROW_NUMBER":"52187","VIOLATION_NO":"8168782","DOCKET_NO":"VA 2010-200","DECISION_DT":"09/09/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"1657.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2010-09-09"},{"SOURCE_ROW_NUMBER":"230305","VIOLATION_NO":"6631814","DOCKET_NO":"VA 2009-56","DECISION_DT":"07/19/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"263.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-07-19"},{"SOURCE_ROW_NUMBER":"29882","VIOLATION_NO":"6631604","DOCKET_NO":"VA 2009-56","DECISION_DT":"07/19/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"263.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-07-19"},{"SOURCE_ROW_NUMBER":"28800","VIOLATION_NO":"6640925","DOCKET_NO":"VA 2009-19","DECISION_DT":"06/24/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2010-06-24"},{"SOURCE_ROW_NUMBER":"222975","VIOLATION_NO":"6631601","DOCKET_NO":"VA 2008-327","DECISION_DT":"05/25/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"600.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-05-25"},{"SOURCE_ROW_NUMBER":"221330","VIOLATION_NO":"6640421","DOCKET_NO":"VA 2008-329","DECISION_DT":"05/25/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"1000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-05-25"},{"SOURCE_ROW_NUMBER":"221263","VIOLATION_NO":"6640425","DOCKET_NO":"VA 2008-329","DECISION_DT":"05/25/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-05-25"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":804,"firstDate":"2003-03-17","lastDate":"2008-11-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":122,"validSamples":682,"maxConcentration":7.88,"concentrationTotal":481.711},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1555961","CASS_NUM":"57774685","SMP_TAKEN_DT":"11/3/2008","CONC":".409","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"1454975","CASS_NUM":"57774732","SMP_TAKEN_DT":"11/3/2008","CONC":".261","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"1228613","CASS_NUM":"57774661","SMP_TAKEN_DT":"11/3/2008","CONC":".248","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"1135081","CASS_NUM":"57774682","SMP_TAKEN_DT":"11/3/2008","CONC":".375","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"1045985","CASS_NUM":"57774687","SMP_TAKEN_DT":"11/3/2008","CONC":".504","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"1021469","CASS_NUM":"57774807","SMP_TAKEN_DT":"11/3/2008","CONC":".342","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"688792","CASS_NUM":"57774662","SMP_TAKEN_DT":"11/3/2008","CONC":".215","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"70933","CASS_NUM":"57774674","SMP_TAKEN_DT":"11/3/2008","CONC":".313","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-03"},{"SOURCE_ROW_NUMBER":"159501","CASS_NUM":"50863760","SMP_TAKEN_DT":"10/23/2008","CONC":".372","SMP_TYPE_CD_DESC":"INVALID SAMPLE TYPE","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID SAMPLE TYPE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"701661","CASS_NUM":"50883631","SMP_TAKEN_DT":"9/29/2008","CONC":".129","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-29"},{"SOURCE_ROW_NUMBER":"457638","CASS_NUM":"50872419","SMP_TAKEN_DT":"9/27/2008","CONC":".13","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-27"},{"SOURCE_ROW_NUMBER":"973300","CASS_NUM":"50899437","SMP_TAKEN_DT":"9/26/2008","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-26"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":66,"firstDate":"2003-03-06","lastDate":"2008-02-04","metrics":{"linkedIssuances":66},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":103,"firstDate":"2006-04-26","lastDate":"2009-09-25","metrics":{"decisions":103,"ssChanged":9,"recentRows":0,"decisionPenalty":57387,"proposedPenalty":99062},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"355811","CITATION_NO":"8168783","CITATION_ISSUE_DT":"09/25/2009","DOCKET_NO":"VA 2010-200","DECISION_DT":"09/09/2010","CFR_STANDARD_CODE":"77.205(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"3689.00","sourceDate":"2009-09-25"},{"SOURCE_ROW_NUMBER":"298671","CITATION_NO":"8168782","CITATION_ISSUE_DT":"09/25/2009","DOCKET_NO":"VA 2010-200","DECISION_DT":"09/09/2010","CFR_STANDARD_CODE":"77.1710(g)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"1657.00","sourceDate":"2009-09-25"},{"SOURCE_ROW_NUMBER":"181483","CITATION_NO":"6640238","CITATION_ISSUE_DT":"11/06/2008","DOCKET_NO":"VA 2009-159","DECISION_DT":"11/20/2009","CFR_STANDARD_CODE":"75.364","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2008-11-06"},{"SOURCE_ROW_NUMBER":"351094","CITATION_NO":"6641185","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"VA 2009-158","DECISION_DT":"11/20/2009","CFR_STANDARD_CODE":"75.360(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"181256","CITATION_NO":"6641184","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"VA 2009-158","DECISION_DT":"11/20/2009","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"66541","CITATION_NO":"6640874","CITATION_ISSUE_DT":"10/28/2008","DOCKET_NO":"VA 2009-158","DECISION_DT":"11/20/2009","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"12413","CITATION_NO":"6640873","CITATION_ISSUE_DT":"10/28/2008","DOCKET_NO":"VA 2009-158","DECISION_DT":"11/20/2009","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"540.00","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"178374","CITATION_NO":"7317936","CITATION_ISSUE_DT":"09/04/2008","DOCKET_NO":"VA 2009-91","DECISION_DT":"09/22/2010","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"191.00","sourceDate":"2008-09-04"},{"SOURCE_ROW_NUMBER":"348534","CITATION_NO":"6631604","CITATION_ISSUE_DT":"08/26/2008","DOCKET_NO":"VA 2009-56","DECISION_DT":"07/19/2010","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"348100","CITATION_NO":"7317929","CITATION_ISSUE_DT":"08/20/2008","DOCKET_NO":"VA 2009-55","DECISION_DT":"11/12/2009","CFR_STANDARD_CODE":"75.1702","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2008-08-20"},{"SOURCE_ROW_NUMBER":"121914","CITATION_NO":"6631814","CITATION_ISSUE_DT":"08/18/2008","DOCKET_NO":"VA 2009-56","DECISION_DT":"07/19/2010","CFR_STANDARD_CODE":"75.900","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2008-08-18"},{"SOURCE_ROW_NUMBER":"347798","CITATION_NO":"6640925","CITATION_ISSUE_DT":"08/04/2008","DOCKET_NO":"VA 2009-19","DECISION_DT":"06/24/2010","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2008-08-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":121,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":32,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1975-01-01","lastDate":"2003-05-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":298,"firstDate":"2002-05-13","lastDate":"2011-03-09","metrics":{"inspectors":404,"recentRows":0,"onSiteHours":4405.25,"inspectionHours":7589.25,"inspectionSamples":268},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"113933","EVENT_NO":"4413074","INSPECTION_BEGIN_DT":"03/09/2011","INSPECTION_END_DT":"03/09/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2011-03-09"},{"SOURCE_ROW_NUMBER":"792883","EVENT_NO":"4413284","INSPECTION_BEGIN_DT":"02/08/2011","INSPECTION_END_DT":"02/28/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2011-02-08"},{"SOURCE_ROW_NUMBER":"22689","EVENT_NO":"4403783","INSPECTION_BEGIN_DT":"08/21/2009","INSPECTION_END_DT":"08/21/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2009-08-21"},{"SOURCE_ROW_NUMBER":"1032","EVENT_NO":"4147549","INSPECTION_BEGIN_DT":"08/13/2009","INSPECTION_END_DT":"09/29/2009","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"49.5","SUM_TOTAL_ON_SITE_HOURS":"13.25","sourceDate":"2009-08-13"},{"SOURCE_ROW_NUMBER":"968216","EVENT_NO":"4403555","INSPECTION_BEGIN_DT":"01/23/2009","INSPECTION_END_DT":"01/23/2009","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2009-01-23"},{"SOURCE_ROW_NUMBER":"349089","EVENT_NO":"4403598","INSPECTION_BEGIN_DT":"11/14/2008","INSPECTION_END_DT":"11/14/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2008-11-14"},{"SOURCE_ROW_NUMBER":"374029","EVENT_NO":"4403596","INSPECTION_BEGIN_DT":"11/05/2008","INSPECTION_END_DT":"11/05/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2008-11-05"},{"SOURCE_ROW_NUMBER":"827815","EVENT_NO":"4403595","INSPECTION_BEGIN_DT":"10/29/2008","INSPECTION_END_DT":"10/29/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2008-10-29"},{"SOURCE_ROW_NUMBER":"253172","EVENT_NO":"4403594","INSPECTION_BEGIN_DT":"10/21/2008","INSPECTION_END_DT":"10/21/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2008-10-21"},{"SOURCE_ROW_NUMBER":"805396","EVENT_NO":"4403593","INSPECTION_BEGIN_DT":"10/17/2008","INSPECTION_END_DT":"10/17/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2008-10-17"},{"SOURCE_ROW_NUMBER":"742010","EVENT_NO":"4403592","INSPECTION_BEGIN_DT":"10/14/2008","INSPECTION_END_DT":"12/16/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"104.5","SUM_TOTAL_ON_SITE_HOURS":"59.75","sourceDate":"2008-10-14"},{"SOURCE_ROW_NUMBER":"643071","EVENT_NO":"4403590","INSPECTION_BEGIN_DT":"10/09/2008","INSPECTION_END_DT":"10/09/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2008-10-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":85,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010-Q1":{"hours":0,"employees":0,"production":0},"2009-Q4":{"hours":0,"employees":0,"production":0},"2009-Q3":{"hours":10,"employees":1,"production":0},"2009-Q2":{"hours":0,"employees":0,"production":0},"2009-Q1":{"hours":0,"employees":0,"production":0},"2008-Q4":{"hours":16667,"employees":31,"production":21771},"2008-Q3":{"hours":27088,"employees":46,"production":55649},"2008-Q2":{"hours":34046,"employees":58,"production":50939},"2008-Q1":{"hours":40367,"employees":63,"production":53181},"2007-Q4":{"hours":37677,"employees":65,"production":57280},"2007-Q3":{"hours":39378,"employees":64,"production":76418},"2007-Q2":{"hours":40234,"employees":67,"production":82888}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003":{"hours":67468,"employees":31,"production":104878},"2004":{"hours":143006,"employees":59,"production":257160},"2005":{"hours":166288,"employees":66,"production":271645},"2006":{"hours":155639,"employees":64,"production":311544},"2007":{"hours":154630,"employees":65,"production":309449},"2008":{"hours":118168,"employees":50,"production":181540},"2009":{"hours":10,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":55,"firstDate":"2003-09-10","lastDate":"2008-02-01","metrics":{"recentRows":0,"doseOver100":9,"actDoseTotal":4005,"pelDoseTotal":3044},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"194924","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"11","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194923","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"49","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194922","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"56","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194921","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"55","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194920","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"53","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194919","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"24","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194918","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"88","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194917","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"42","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194916","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"115","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194915","EVENT_NO":"4402856","SURVEY_DATE":"02/01/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"050","ACT_DOSE_85":"57","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2008-02-01"},{"SOURCE_ROW_NUMBER":"194914","EVENT_NO":"4402672","SURVEY_DATE":"08/10/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"41","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2007-08-10"},{"SOURCE_ROW_NUMBER":"194913","EVENT_NO":"4402672","SURVEY_DATE":"08/10/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"29","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2007-08-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":61,"firstDate":"2003-07-23","lastDate":"2008-02-20","metrics":{"recentRows":0,"voidSamples":6,"maxQuartzPct":18.4,"validSamples":55,"quartzPctTotal":376.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"164714","CASSETTE_NO":"57686150","SAMPLE_DT":"02/20/2008","QUARTZ_PCT":"07.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-02-20"},{"SOURCE_ROW_NUMBER":"69116","CASSETTE_NO":"57686180","SAMPLE_DT":"02/20/2008","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-02-20"},{"SOURCE_ROW_NUMBER":"8254","CASSETTE_NO":"57686217","SAMPLE_DT":"01/10/2008","QUARTZ_PCT":"10.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-01-10"},{"SOURCE_ROW_NUMBER":"101369","CASSETTE_NO":"57683738","SAMPLE_DT":"10/30/2007","QUARTZ_PCT":"01.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-10-30"},{"SOURCE_ROW_NUMBER":"58449","CASSETTE_NO":"57683669","SAMPLE_DT":"10/30/2007","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-10-30"},{"SOURCE_ROW_NUMBER":"119439","CASSETTE_NO":"57684844","SAMPLE_DT":"07/17/2007","QUARTZ_PCT":"08.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-07-17"},{"SOURCE_ROW_NUMBER":"47933","CASSETTE_NO":"57684836","SAMPLE_DT":"07/17/2007","QUARTZ_PCT":"07.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-07-17"},{"SOURCE_ROW_NUMBER":"157489","CASSETTE_NO":"50674141","SAMPLE_DT":"07/09/2007","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2007-07-09"},{"SOURCE_ROW_NUMBER":"127666","CASSETTE_NO":"57684930","SAMPLE_DT":"06/20/2007","QUARTZ_PCT":"10.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-20"},{"SOURCE_ROW_NUMBER":"97142","CASSETTE_NO":"57685027","SAMPLE_DT":"06/20/2007","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-20"},{"SOURCE_ROW_NUMBER":"132270","CASSETTE_NO":"57671528","SAMPLE_DT":"03/08/2007","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-08"},{"SOURCE_ROW_NUMBER":"50508","CASSETTE_NO":"57671536","SAMPLE_DT":"03/08/2007","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":521,"firstDate":"2002-12-03","lastDate":"2009-09-25","metrics":{"ss":205,"amountDue":131375,"contested":98,"amountPaid":129384,"recentRows":0,"section104d":0,"unterminated":4,"proposedPenalty":169283},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2314944","VIOLATION_NO":"8168783","VIOLATION_ISSUE_DT":"09/25/2009","SIG_SUB":"Y","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Occurred","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2009","PROPOSED_PENALTY":"3689","AMOUNT_DUE":"3689","AMOUNT_PAID":"3689","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-200","sourceDate":"2009-09-25"},{"SOURCE_ROW_NUMBER":"2314943","VIOLATION_NO":"8168782","VIOLATION_ISSUE_DT":"09/25/2009","SIG_SUB":"Y","PART_SECTION":"77.1710(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Occurred","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/25/2009","PROPOSED_PENALTY":"3689","AMOUNT_DUE":"1657","AMOUNT_PAID":"1657","CONTESTED_IND":"Y","DOCKET_NO":"VA 2010-200","sourceDate":"2009-09-25"},{"SOURCE_ROW_NUMBER":"2314942","VIOLATION_NO":"8167085","VIOLATION_ISSUE_DT":"08/13/2009","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"09/28/2009","CONTESTED_IND":"N","sourceDate":"2009-08-13"},{"SOURCE_ROW_NUMBER":"2315079","VIOLATION_NO":"6640238","VIOLATION_ISSUE_DT":"11/06/2008","SIG_SUB":"N","PART_SECTION":"75.364","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/21/2008","PROPOSED_PENALTY":"117","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"Y","DOCKET_NO":"VA 2009-159","sourceDate":"2008-11-06"},{"SOURCE_ROW_NUMBER":"2315078","VIOLATION_NO":"6640237","VIOLATION_ISSUE_DT":"11/06/2008","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"11/21/2008","CONTESTED_IND":"N","sourceDate":"2008-11-06"},{"SOURCE_ROW_NUMBER":"2315087","VIOLATION_NO":"6641186","VIOLATION_ISSUE_DT":"10/31/2008","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/31/2008","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"190","CONTESTED_IND":"N","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"2315086","VIOLATION_NO":"6641185","VIOLATION_ISSUE_DT":"10/31/2008","SIG_SUB":"Y","PART_SECTION":"75.360(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/31/2008","PROPOSED_PENALTY":"585","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"Y","DOCKET_NO":"VA 2009-158","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"2315085","VIOLATION_NO":"6641184","VIOLATION_ISSUE_DT":"10/31/2008","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/31/2008","PROPOSED_PENALTY":"807","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"Y","DOCKET_NO":"VA 2009-158","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"2315084","VIOLATION_NO":"6641183","VIOLATION_ISSUE_DT":"10/31/2008","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/31/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"2315083","VIOLATION_NO":"6640874","VIOLATION_ISSUE_DT":"10/28/2008","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/28/2008","PROPOSED_PENALTY":"807","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"Y","DOCKET_NO":"VA 2009-158","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"2315082","VIOLATION_NO":"6640873","VIOLATION_ISSUE_DT":"10/28/2008","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/28/2008","PROPOSED_PENALTY":"1203","AMOUNT_DUE":"540","AMOUNT_PAID":"540","CONTESTED_IND":"Y","DOCKET_NO":"VA 2009-158","sourceDate":"2008-10-28"},{"SOURCE_ROW_NUMBER":"2315081","VIOLATION_NO":"6640872","VIOLATION_ISSUE_DT":"10/28/2008","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2008","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2008-10-28"}]}],"safety":{"href":"/api/v1/mines/4403932/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4403932/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4403932","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}