{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4400285","name":"No 1","status":"Abandoned and Sealed","status_date":"2003-12-29","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"VA","county":"Wise","nearest_town":"Norton","operator_id":"P22914","operator_name":"Regent Allied Carbon Energy Inc","controller_id":"C04393","controller_name":"Ervin  Stiltner","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.041666,"longitude":-82.675},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1082},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4400285","name":"No 1"},"operator":{"type":"operator","id":"P22914","name":"Regent Allied Carbon Energy Inc"},"controller":{"type":"controller","id":"C04393","name":"Ervin  Stiltner"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01816","name":"Old Ben Coal Company"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1950-01-01","validTo":"1977-09-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P01816|1950-01-01|1977-09-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01532","name":"British Petroleum Company PLC"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|C01532|1950-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01532","name":"British Petroleum Company PLC"},"object":{"type":"operator","id":"P01816","name":"Old Ben Coal Company"},"validFrom":"1950-01-01","validTo":"1977-09-18","current":false,"derived":true,"evidenceMineId":"4400285","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P01816|1950-01-01|C01532|1950-01-01|54491"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01963","name":"Flat Gap Mining Company Inc"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1977-09-19","validTo":"1981-10-28","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P01963|1977-09-19|1981-10-28"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01655","name":"Hurshel  Bowers et al"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1977-09-19","validTo":"1981-11-02","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|C01655|1977-09-19|1981-11-02"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01655","name":"Hurshel  Bowers et al"},"object":{"type":"operator","id":"P01963","name":"Flat Gap Mining Company Inc"},"validFrom":"1977-09-19","validTo":"1981-10-28","current":false,"derived":true,"evidenceMineId":"4400285","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P01963|1977-09-19|C01655|1977-09-19|55500"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P12586","name":"Sturgill Mining Company"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1981-10-29","validTo":"1985-09-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P12586|1981-10-29|1985-09-17"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C09296","name":"Delbert R  Sturgill"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1981-10-29","validTo":"1985-09-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|C09296|1981-10-29|1985-09-17"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09296","name":"Delbert R  Sturgill"},"object":{"type":"operator","id":"P12586","name":"Sturgill Mining Company"},"validFrom":"1981-10-29","validTo":"1985-09-17","current":false,"derived":true,"evidenceMineId":"4400285","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P12586|1981-10-29|C09296|1981-10-29|79269"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17416","name":"Metro Coal Company Inc"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1985-09-18","validTo":"1994-09-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P17416|1985-09-18|1994-09-25"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11007","name":"Malcom  Gatt"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1985-09-18","validTo":"1994-09-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|C11007|1985-09-18|1994-09-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11007","name":"Malcom  Gatt"},"object":{"type":"operator","id":"P17416","name":"Metro Coal Company Inc"},"validFrom":"1985-09-18","validTo":"1994-09-25","current":false,"derived":true,"evidenceMineId":"4400285","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P17416|1985-09-18|C11007|1985-09-18|83417"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22914","name":"Regent Allied Carbon Energy Inc"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1994-09-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P22914|1994-09-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C04393","name":"Ervin  Stiltner"},"object":{"type":"mine","id":"4400285","name":"No 1"},"validFrom":"1994-09-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|C04393|1994-09-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04393","name":"Ervin  Stiltner"},"object":{"type":"operator","id":"P22914","name":"Regent Allied Carbon Energy Inc"},"validFrom":"1994-09-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"4400285","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4400285|P22914|1994-09-26|C04393|1994-09-26|65907"}}],"coverage":{"historyRecords":5,"edgeCount":15,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2000-02-01","lastDate":"2003-02-21","metrics":{"daysLost":135,"injuries":5,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"106162","DOCUMENT_NO":"220030690069","ACCIDENT_DT":"02/21/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"67","NARRATIVE":"EMPLOYEE WAS HOOKING UP CHAIN TO LIFT ROOF BOLTS UP WITH THE ENDLOADER, THE OPERATOR WAS GOING TO BACK THE LOADER UP, WHEN THE LOADER WENT FORWARD STRIKING EMPLOYEE ON THE RIGHT LEG.","sourceDate":"2003-02-21"},{"SOURCE_ROW_NUMBER":"153791","DOCUMENT_NO":"220023470017","ACCIDENT_DT":"12/02/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AT SPAD #1486 ROCK FALL IN #6 ENTRY ON MAINS EXTENDED INBY FOR A DISTANCE OF APPROX 80' - 20' WIDE AND 5' THICK. AREA HAD ALREADY BEN TIMBERED AND DANGERED OFF PRIOR TO FALL. APPROX 650' OUTBY WORKING SECTION - SECTION IS ON RETREAT MINING.","sourceDate":"2002-12-02"},{"SOURCE_ROW_NUMBER":"46252","DOCUMENT_NO":"220021930020","ACCIDENT_DT":"07/08/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"THE SECTION FOREMAN WAS HELPING MOVE THE CONT. MINER TO ANOTHER WORKING PLACE WHILE WATCHING THE MINER CABLE A PIECE OF ROCK FELL FROM BETWEEN THE ROOF BOLTS STRIKING HIM ON THE RIGHT SHOULDER AND ARM.","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"205393","DOCUMENT_NO":"220020500047","ACCIDENT_DT":"02/11/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"41","NARRATIVE":"ROOF BOLTER OPER. WAS INSTALLING A ROOF BOLT IN THE ROOF-HE PUSHED IT UP ABOUT 2/3 OF THE WAY THE BOLT BENT. HE SET THE MACHINE OVER TO PUT UP ANOTHER BOLT HE PUSHED THE LEVER THE WRONG WAY-TH E HEAD CAME OVER ON HIS LEFT KNEE.","sourceDate":"2002-02-11"},{"SOURCE_ROW_NUMBER":"136464","DOCUMENT_NO":"220012780073","ACCIDENT_DT":"09/27/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"APPROX 20' IN BY SPAD 1334 IN #5 ENTRY ON MAINS, A ROOF FALL OCCURRED, THE FALL LOOKS TO BE APPROX 0-5' THICK IN BY RANGES UP TO 5' THICK FOR A DISTANCE OF APPROX 230' IN LENGTH.","sourceDate":"2001-09-27"},{"SOURCE_ROW_NUMBER":"158105","DOCUMENT_NO":"220012710065","ACCIDENT_DT":"09/24/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"APPROX. 15' INBY SPAD #1359 IN #4 ENTRY ON MAINS(BELT) A ROOF FALL WAS DISCOVERED DURING THE PRESHIFT. FALL MEASURED ~20' WIDE; STARTS OUT ~3'ONONE END & ~5' THICK ON THE OTHER FOR A DISTANCE OF ~170' IN LENGTH. ROOF WAS BOLTED WITH 4' RESIN RODS.","sourceDate":"2001-09-24"},{"SOURCE_ROW_NUMBER":"226937","DOCUMENT_NO":"220002270073","ACCIDENT_DT":"08/07/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"CONT. MINR OPERATOR WAS CUTTING THE #4 RIGHT CROSS CUT THEN HE HAD HIS BACK TURNED TOWARD THE RIB. WHEN A PIECE OF ROCK ROLLED FROM THE RIB STRIKING HIM IN HIS LOWER BACK.","sourceDate":"2000-08-07"},{"SOURCE_ROW_NUMBER":"76405","DOCUMENT_NO":"220001290029","ACCIDENT_DT":"05/04/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"DISCOVERED A ROOF FALL ON THE INTAKE IN #3 ENTRY APPROX 400' UNDERGROUND FROM THE SURFACE AT SPAD #15. THE FALL WAS IN AN AREA THAT HAS BEEN CRIBBED OFF FOR APPROX 2 MONTHS OR LONGER. THE FALL IS APPROX 12'W, 5'H, 15'L. THIS ENTRY WAS NOT BEING USED AS A TRAVELWAY.","sourceDate":"2000-05-04"},{"SOURCE_ROW_NUMBER":"239887","DOCUMENT_NO":"220000400022","ACCIDENT_DT":"02/01/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Flash burns (electric)","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"EE SAW THE CIRCUIT BREAKER FOR THE ROOF BOLTER HAD DROPPED OUT-WHEN HE WENT TO RESET IT-IT WENT PHASE TO PHASE AND BURNT HIS FINGERS.","sourceDate":"2000-02-01"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2003-12-29","lastDate":"2003-12-29","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":209,"firstDate":"2000-02-15","lastDate":"2003-09-08","metrics":{"ss":104,"delinquent":209,"recentRows":0,"paidPenalty":26843,"proposedPenalty":26843,"currentAssessment":26843},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"883354","VIOLATION_NO":"7332987","ISSUE_DT":"09/08/2003","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"346.00","CURRENT_ASSESSMENT_AMT":"346.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-09-08"},{"SOURCE_ROW_NUMBER":"883353","VIOLATION_NO":"7332986","ISSUE_DT":"09/08/2003","CFR_STANDARD_CD":"75.333(e)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-09-08"},{"SOURCE_ROW_NUMBER":"883352","VIOLATION_NO":"7332985","ISSUE_DT":"09/08/2003","CFR_STANDARD_CD":"75.1202-1(b)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-09-08"},{"SOURCE_ROW_NUMBER":"892891","VIOLATION_NO":"7329927","ISSUE_DT":"08/04/2003","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-08-04"},{"SOURCE_ROW_NUMBER":"892890","VIOLATION_NO":"7329926","ISSUE_DT":"08/03/2003","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-08-03"},{"SOURCE_ROW_NUMBER":"892889","VIOLATION_NO":"7329924","ISSUE_DT":"07/21/2003","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-21"},{"SOURCE_ROW_NUMBER":"892883","VIOLATION_NO":"7324045","ISSUE_DT":"06/11/2003","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-06-11"},{"SOURCE_ROW_NUMBER":"892882","VIOLATION_NO":"7324044","ISSUE_DT":"06/09/2003","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-06-09"},{"SOURCE_ROW_NUMBER":"892884","VIOLATION_NO":"7324060","ISSUE_DT":"06/08/2003","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-06-08"},{"SOURCE_ROW_NUMBER":"881506","VIOLATION_NO":"7315097","ISSUE_DT":"05/22/2003","CFR_STANDARD_CD":"75.335(a)(1)(iv)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"164.00","CURRENT_ASSESSMENT_AMT":"164.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"892885","VIOLATION_NO":"7324138","ISSUE_DT":"05/16/2003","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-16"},{"SOURCE_ROW_NUMBER":"881503","VIOLATION_NO":"7315094","ISSUE_DT":"05/09/2003","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-09"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":317,"firstDate":"2000-01-17","lastDate":"2003-09-17","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":21,"validSamples":296,"maxConcentration":9.009,"concentrationTotal":196.322},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1108916","CASS_NUM":"57491969","SMP_TAKEN_DT":"9/17/2003","CONC":".152","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-09-17"},{"SOURCE_ROW_NUMBER":"1005357","CASS_NUM":"57492037","SMP_TAKEN_DT":"9/17/2003","CONC":".246","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-09-17"},{"SOURCE_ROW_NUMBER":"563007","CASS_NUM":"57492002","SMP_TAKEN_DT":"9/17/2003","CONC":".168","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-09-17"},{"SOURCE_ROW_NUMBER":"531012","CASS_NUM":"57492020","SMP_TAKEN_DT":"9/17/2003","CONC":".224","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-09-17"},{"SOURCE_ROW_NUMBER":"451439","CASS_NUM":"57492000","SMP_TAKEN_DT":"9/17/2003","CONC":".584","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-09-17"},{"SOURCE_ROW_NUMBER":"1134475","CASS_NUM":"57518845","SMP_TAKEN_DT":"7/22/2003","CONC":".689","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"1108408","CASS_NUM":"57518895","SMP_TAKEN_DT":"7/22/2003","CONC":".174","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"1084074","CASS_NUM":"57518857","SMP_TAKEN_DT":"7/22/2003","CONC":".423","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"836575","CASS_NUM":"57518850","SMP_TAKEN_DT":"7/22/2003","CONC":".346","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"818501","CASS_NUM":"57518892","SMP_TAKEN_DT":"7/22/2003","CONC":".598","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"485635","CASS_NUM":"57518852","SMP_TAKEN_DT":"7/22/2003","CONC":".598","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"1182152","CASS_NUM":"50677523","SMP_TAKEN_DT":"7/17/2003","CONC":".477","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-17"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2001-02-28","lastDate":"2002-08-27","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":122,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1950-01-01","lastDate":"1994-09-26","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":85,"firstDate":"2000-01-04","lastDate":"2003-12-02","metrics":{"inspectors":104,"recentRows":0,"onSiteHours":1315.5,"inspectionHours":2151.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1026526","EVENT_NO":"4138441","INSPECTION_BEGIN_DT":"12/02/2003","INSPECTION_END_DT":"12/02/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2003-12-02"},{"SOURCE_ROW_NUMBER":"504078","EVENT_NO":"4138425","INSPECTION_BEGIN_DT":"09/17/2003","INSPECTION_END_DT":"10/03/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2003-09-17"},{"SOURCE_ROW_NUMBER":"917329","EVENT_NO":"4131299","INSPECTION_BEGIN_DT":"09/05/2003","INSPECTION_END_DT":"09/15/2003","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"10.25","sourceDate":"2003-09-05"},{"SOURCE_ROW_NUMBER":"195131","EVENT_NO":"4138418","INSPECTION_BEGIN_DT":"07/22/2003","INSPECTION_END_DT":"08/11/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"178760","EVENT_NO":"4138417","INSPECTION_BEGIN_DT":"07/17/2003","INSPECTION_END_DT":"09/05/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"62","SUM_TOTAL_ON_SITE_HOURS":"37","sourceDate":"2003-07-17"},{"SOURCE_ROW_NUMBER":"248479","EVENT_NO":"4128444","INSPECTION_BEGIN_DT":"05/20/2003","INSPECTION_END_DT":"05/28/2003","ACTIVITY_CODE":"CEA","ACTIVITY":"ROOF CONTROL TECHNICAL INVESTIGTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2003-05-20"},{"SOURCE_ROW_NUMBER":"50724","EVENT_NO":"4138408","INSPECTION_BEGIN_DT":"05/20/2003","INSPECTION_END_DT":"07/07/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"77","SUM_TOTAL_ON_SITE_HOURS":"48","sourceDate":"2003-05-20"},{"SOURCE_ROW_NUMBER":"778961","EVENT_NO":"4138407","INSPECTION_BEGIN_DT":"05/13/2003","INSPECTION_END_DT":"06/24/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"73","SUM_TOTAL_ON_SITE_HOURS":"43.5","sourceDate":"2003-05-13"},{"SOURCE_ROW_NUMBER":"686245","EVENT_NO":"4128439","INSPECTION_BEGIN_DT":"05/08/2003","INSPECTION_END_DT":"05/12/2003","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"7.25","sourceDate":"2003-05-08"},{"SOURCE_ROW_NUMBER":"419317","EVENT_NO":"4128431","INSPECTION_BEGIN_DT":"04/04/2003","INSPECTION_END_DT":"04/07/2003","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2003-04-04"},{"SOURCE_ROW_NUMBER":"1103450","EVENT_NO":"4138402","INSPECTION_BEGIN_DT":"03/18/2003","INSPECTION_END_DT":"03/18/2003","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2003-03-18"},{"SOURCE_ROW_NUMBER":"244993","EVENT_NO":"4138565","INSPECTION_BEGIN_DT":"03/06/2003","INSPECTION_END_DT":"03/21/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2003-03-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":19361,"employees":36,"production":67861},"2002-Q3":{"hours":19473,"employees":37,"production":55844},"2002-Q2":{"hours":21375,"employees":36,"production":56326},"2002-Q1":{"hours":21232,"employees":36,"production":56685},"2001-Q4":{"hours":21756,"employees":37,"production":55502},"2001-Q3":{"hours":19968,"employees":36,"production":48829},"2001-Q2":{"hours":21129,"employees":37,"production":61906},"2001-Q1":{"hours":21034,"employees":37,"production":73205},"2000-Q4":{"hours":21046,"employees":38,"production":63300},"2000-Q3":{"hours":19142,"employees":37,"production":70498},"2000-Q2":{"hours":21322,"employees":36,"production":75052},"2000-Q1":{"hours":20271,"employees":38,"production":70025}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":81781,"employees":37,"production":278875},"2001":{"hours":83887,"employees":37,"production":239442},"2002":{"hours":81441,"employees":36,"production":236716},"2003":{"hours":52467,"employees":33,"production":178207}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":20,"firstDate":"2001-02-14","lastDate":"2003-03-18","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1429,"pelDoseTotal":1026},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"193516","EVENT_NO":"4138402","SURVEY_DATE":"03/18/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"27","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2003-03-18"},{"SOURCE_ROW_NUMBER":"193515","EVENT_NO":"4138402","SURVEY_DATE":"03/18/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"35","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2003-03-18"},{"SOURCE_ROW_NUMBER":"193514","EVENT_NO":"4138402","SURVEY_DATE":"03/18/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"62","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2003-03-18"},{"SOURCE_ROW_NUMBER":"193513","EVENT_NO":"4138402","SURVEY_DATE":"03/18/2003","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"132","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2003-03-18"},{"SOURCE_ROW_NUMBER":"193512","EVENT_NO":"4138402","SURVEY_DATE":"03/18/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"132","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2003-03-18"},{"SOURCE_ROW_NUMBER":"193511","EVENT_NO":"4138220","SURVEY_DATE":"06/12/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"75","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2002-06-12"},{"SOURCE_ROW_NUMBER":"193510","EVENT_NO":"4138220","SURVEY_DATE":"06/12/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"16","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2002-06-12"},{"SOURCE_ROW_NUMBER":"193509","EVENT_NO":"4138220","SURVEY_DATE":"06/12/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2002-06-12"},{"SOURCE_ROW_NUMBER":"193508","EVENT_NO":"4138220","SURVEY_DATE":"06/12/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"71","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2002-06-12"},{"SOURCE_ROW_NUMBER":"193507","EVENT_NO":"4138220","SURVEY_DATE":"06/12/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"91","PEL_DOSE_90":"73","SURVEY_TYPE":"I","sourceDate":"2002-06-12"},{"SOURCE_ROW_NUMBER":"193506","EVENT_NO":"4137635","SURVEY_DATE":"05/30/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"83","PEL_DOSE_90":"64","SURVEY_TYPE":"F","sourceDate":"2001-05-30"},{"SOURCE_ROW_NUMBER":"193497","EVENT_NO":"4137622","SURVEY_DATE":"03/01/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"50","PEL_DOSE_90":"36","SURVEY_TYPE":"F","sourceDate":"2001-03-01"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":46,"firstDate":"2000-04-06","lastDate":"2003-07-22","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":15.8,"validSamples":44,"quartzPctTotal":233.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"163962","CASSETTE_NO":"57518845","SAMPLE_DT":"07/22/2003","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"38916","CASSETTE_NO":"57518892","SAMPLE_DT":"07/22/2003","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"22340","CASSETTE_NO":"57518852","SAMPLE_DT":"07/22/2003","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-07-22"},{"SOURCE_ROW_NUMBER":"116413","CASSETTE_NO":"57519052","SAMPLE_DT":"05/21/2003","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"114817","CASSETTE_NO":"57519126","SAMPLE_DT":"05/21/2003","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"94739","CASSETTE_NO":"57519174","SAMPLE_DT":"05/21/2003","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-05-21"},{"SOURCE_ROW_NUMBER":"155117","CASSETTE_NO":"57477152","SAMPLE_DT":"03/10/2003","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-10"},{"SOURCE_ROW_NUMBER":"70640","CASSETTE_NO":"57477490","SAMPLE_DT":"03/10/2003","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-10"},{"SOURCE_ROW_NUMBER":"27402","CASSETTE_NO":"57477529","SAMPLE_DT":"03/10/2003","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-10"},{"SOURCE_ROW_NUMBER":"118860","CASSETTE_NO":"57477306","SAMPLE_DT":"02/06/2003","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-02-06"},{"SOURCE_ROW_NUMBER":"160836","CASSETTE_NO":"57444653","SAMPLE_DT":"11/15/2002","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-11-15"},{"SOURCE_ROW_NUMBER":"38891","CASSETTE_NO":"57445097","SAMPLE_DT":"11/15/2002","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-11-15"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":210,"firstDate":"2000-02-15","lastDate":"2003-09-08","metrics":{"ss":105,"amountDue":26843,"contested":0,"amountPaid":26843,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":26843},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2300697","VIOLATION_NO":"7332987","VIOLATION_ISSUE_DT":"09/08/2003","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/15/2003","PROPOSED_PENALTY":"346","AMOUNT_DUE":"346","AMOUNT_PAID":"346","CONTESTED_IND":"N","sourceDate":"2003-09-08"},{"SOURCE_ROW_NUMBER":"2300696","VIOLATION_NO":"7332986","VIOLATION_ISSUE_DT":"09/08/2003","SIG_SUB":"N","PART_SECTION":"75.333(e)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"6","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-09-08"},{"SOURCE_ROW_NUMBER":"2300695","VIOLATION_NO":"7332985","VIOLATION_ISSUE_DT":"09/08/2003","SIG_SUB":"N","PART_SECTION":"75.1202-1(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-09-08"},{"SOURCE_ROW_NUMBER":"2300673","VIOLATION_NO":"7329927","VIOLATION_ISSUE_DT":"08/04/2003","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/04/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-08-04"},{"SOURCE_ROW_NUMBER":"2300672","VIOLATION_NO":"7329926","VIOLATION_ISSUE_DT":"08/03/2003","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/03/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-08-03"},{"SOURCE_ROW_NUMBER":"2300671","VIOLATION_NO":"7329924","VIOLATION_ISSUE_DT":"07/21/2003","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/22/2003","PROPOSED_PENALTY":"226","AMOUNT_DUE":"226","AMOUNT_PAID":"226","CONTESTED_IND":"N","sourceDate":"2003-07-21"},{"SOURCE_ROW_NUMBER":"2300647","VIOLATION_NO":"7324045","VIOLATION_ISSUE_DT":"06/11/2003","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2003","PROPOSED_PENALTY":"226","AMOUNT_DUE":"226","AMOUNT_PAID":"226","CONTESTED_IND":"N","sourceDate":"2003-06-11"},{"SOURCE_ROW_NUMBER":"2300646","VIOLATION_NO":"7324044","VIOLATION_ISSUE_DT":"06/09/2003","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/09/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-06-09"},{"SOURCE_ROW_NUMBER":"2300648","VIOLATION_NO":"7324060","VIOLATION_ISSUE_DT":"06/08/2003","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/08/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-06-08"},{"SOURCE_ROW_NUMBER":"2300651","VIOLATION_NO":"7315097","VIOLATION_ISSUE_DT":"05/22/2003","SIG_SUB":"Y","PART_SECTION":"75.335(a)(1)(iv)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/22/2003","PROPOSED_PENALTY":"164","AMOUNT_DUE":"164","AMOUNT_PAID":"164","CONTESTED_IND":"N","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"2300649","VIOLATION_NO":"7324138","VIOLATION_ISSUE_DT":"05/16/2003","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-05-16"},{"SOURCE_ROW_NUMBER":"2300645","VIOLATION_NO":"7315094","VIOLATION_ISSUE_DT":"05/09/2003","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/09/2003","PROPOSED_PENALTY":"226","AMOUNT_DUE":"226","AMOUNT_PAID":"226","CONTESTED_IND":"N","sourceDate":"2003-05-09"}]}],"safety":{"href":"/api/v1/mines/4400285/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4400285/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Temporary notations, revisions, and supplements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1202-1","part":"75","subchapter":"O","subpart":"M","id":"75.1202-1","citation":"30 CFR 75.1202-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Seal strengths, design applications, and installation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.335","part":"75","subchapter":"O","subpart":"D","id":"75.335","citation":"30 CFR 75.335","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4400285","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}