{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4202241","name":"Lila Canyon","status":"Abandoned and Sealed","status_date":"2024-12-02","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"UT","county":"Emery","nearest_town":"East Carbon, UT","operator_id":"0173613","operator_name":"Emery County Coal Resources, Inc.","controller_id":"0157801","controller_name":"ACNR Holdings, Inc","district":"C09","office":"Price UT Field Office","employees":0,"latitude":39.426111,"longitude":-110.340556},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":15094},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4202241","name":"Lila Canyon"},"operator":{"type":"operator","id":"0173613","name":"Emery County Coal Resources, Inc."},"controller":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24505","name":"Utah American Energy, Inc."},"object":{"type":"mine","id":"4202241","name":"Lila Canyon"},"validFrom":"1999-02-24","validTo":"2020-09-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4202241|P24505|1999-02-24|2020-09-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"4202241","name":"Lila Canyon"},"validFrom":"1999-02-24","validTo":"2020-09-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4202241|C13408|1999-02-24|2020-09-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"P24505","name":"Utah American Energy, Inc."},"validFrom":"1999-02-24","validTo":"2020-09-16","current":false,"derived":true,"evidenceMineId":"4202241","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4202241|P24505|1999-02-24|C13408|1999-02-24|89572"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"mine","id":"4202241","name":"Lila Canyon"},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4202241|0157801|2020-09-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"operator","id":"P24505","name":"Utah American Energy, Inc."},"validFrom":"2020-09-17","validTo":"2020-09-16","current":false,"derived":true,"evidenceMineId":"4202241","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4202241|P24505|1999-02-24|0157801|2020-09-17|32654"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0173613","name":"Emery County Coal Resources, Inc."},"object":{"type":"mine","id":"4202241","name":"Lila Canyon"},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4202241|0173613|2020-09-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0157801","name":"ACNR Holdings, Inc"},"object":{"type":"operator","id":"0173613","name":"Emery County Coal Resources, Inc."},"validFrom":"2020-09-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"4202241","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4202241|0173613|2020-09-17|0157801|2020-09-17|32655"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":117,"firstDate":"2009-06-30","lastDate":"2023-12-04","metrics":{"daysLost":1997,"injuries":117,"fatalities":0,"recentRows":32,"restrictedDays":378,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"76370","DOCUMENT_NO":"220233450002","ACCIDENT_DT":"12/04/2023","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was stacking 60 inch top roller clusters on a pile when EE lost EE's grip on the roller and it fell out of EE's hand and smashed EE's right pinky finger. 5 sutures were required to close the wound.","sourceDate":"2023-12-04"},{"SOURCE_ROW_NUMBER":"196591","DOCUMENT_NO":"220230580032","ACCIDENT_DT":"02/01/2023","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was walking in the #5 entry of 3rd East Mains between XC 6-7 when foot slipped and EE fell to the ground. As EE fell to the ground, EE reached out with left hand to catch the fall, resulting in an injury to EE's left thumb. X-rays indicated a fractured thumb.","sourceDate":"2023-02-01"},{"SOURCE_ROW_NUMBER":"179602","DOCUMENT_NO":"220231860010","ACCIDENT_DT":"09/20/2022","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FIRE","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A fire was identified out-by the 7th South #2 seal at approximately 9:58 PM. Efforts to extinguish the fire were unsuccessful, All miners were evacuated. There were no injuries to any miners.","sourceDate":"2022-09-20"},{"SOURCE_ROW_NUMBER":"46205","DOCUMENT_NO":"220222620023","ACCIDENT_DT":"09/09/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"While walking up the longwall face at approximately shield # 112, the employee tripped and lost balance and hit head on the shield leg.","sourceDate":"2022-09-09"},{"SOURCE_ROW_NUMBER":"16108","DOCUMENT_NO":"220222240010","ACCIDENT_DT":"08/05/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"48","NARRATIVE":"Employee was operating the left side of the roof bolter located in the #2 entry face of 12th North, when their foot slipped and they fell hitting right knee and left wrist on the operators platform that they was standing on.","sourceDate":"2022-08-05"},{"SOURCE_ROW_NUMBER":"16107","DOCUMENT_NO":"220222240004","ACCIDENT_DT":"08/02/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee unhooked a chain that was holding up a bundle of wire mesh roof screens that were leaning against the rib in the 12th north section. The bundle of screens fell over and hit the employee and knocked EE to the ground.","sourceDate":"2022-08-02"},{"SOURCE_ROW_NUMBER":"7532","DOCUMENT_NO":"220222200004","ACCIDENT_DT":"07/28/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"While attempting to attach the fork attachment to the mounting plate on a Ghel skid steer in the 10th North Section, the forks fell off of the attachment mount and landed on employees left foot.","sourceDate":"2022-07-28"},{"SOURCE_ROW_NUMBER":"145064","DOCUMENT_NO":"220222130009","ACCIDENT_DT":"07/23/2022","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was stacking used belt structure onto a flat bed trailer. The stack of rollers started to tip over and as the employee reached with right hand, a roller smashed right hand against the bed of the trailer resulting in a laceration to the hand which required stitches.","sourceDate":"2022-07-23"},{"SOURCE_ROW_NUMBER":"76369","DOCUMENT_NO":"220222010013","ACCIDENT_DT":"07/13/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between running or meshing objects","OCCUPATION":"LW Propman, Propman helper, Move crew if LW, Move-up man, Jacksetter, Advanceman LW helper","NO_INJURIES":"1","DAYS_LOST":"44","NARRATIVE":"Employee was kneeling down on shield #2 on the 9th North longwall face preparing to push the headgate drive. As they pushed the drive, their left foot was pinched between the relay bar and the shield toe.","sourceDate":"2022-07-13"},{"SOURCE_ROW_NUMBER":"239840","DOCUMENT_NO":"220222000010","ACCIDENT_DT":"07/11/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"2","DAYS_LOST":"2","NARRATIVE":"While standing on shield #124 on the 9th North longwall face, the bret-by cable flipped out of the cable tray and stuck the employee, thus knocking the employee to the ground.","sourceDate":"2022-07-11"},{"SOURCE_ROW_NUMBER":"192379","DOCUMENT_NO":"220222000023","ACCIDENT_DT":"07/11/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"2","DAYS_LOST":"2","NARRATIVE":"While standing at shield #125 on the 9th North longwall face, the bret-by cable flipped out of the cable tray and struck the employee, thus knocking EE to the ground.","sourceDate":"2022-07-11"},{"SOURCE_ROW_NUMBER":"200948","DOCUMENT_NO":"220221580004","ACCIDENT_DT":"06/03/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"48","NARRATIVE":"The employee was getting out of the cab of a shuttle car at crosscut 37 in the 4th East Mains Development section, when EE's foot slipped on the mine floor, causing EE to fall to the mine floor. As EE fell EE tried to catch EE's fall with EE's left hand, resulting in a fracture to EE's left wrist.","sourceDate":"2022-06-03"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2024-12-02","lastDate":"2024-12-02","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1541,"firstDate":"2009-05-05","lastDate":"2023-12-18","metrics":{"ss":125,"delinquent":1515,"recentRows":346,"paidPenalty":578739,"proposedPenalty":717483.2,"currentAssessment":606905},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2519147","VIOLATION_NO":"9730503","ISSUE_DT":"12/18/2023","CFR_STANDARD_CD":"77.1303(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-12-18"},{"SOURCE_ROW_NUMBER":"2033951","VIOLATION_NO":"9730533","ISSUE_DT":"10/26/2023","CFR_STANDARD_CD":"75.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-10-26"},{"SOURCE_ROW_NUMBER":"2033950","VIOLATION_NO":"9730532","ISSUE_DT":"10/18/2023","CFR_STANDARD_CD":"77.401(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"155.00","CURRENT_ASSESSMENT_AMT":"155.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-10-18"},{"SOURCE_ROW_NUMBER":"2519105","VIOLATION_NO":"9155457","ISSUE_DT":"09/09/2023","CFR_STANDARD_CD":"75.380(d)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"518.00","CURRENT_ASSESSMENT_AMT":"518.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-09-09"},{"SOURCE_ROW_NUMBER":"2519104","VIOLATION_NO":"9155456","ISSUE_DT":"09/08/2023","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"198.00","CURRENT_ASSESSMENT_AMT":"198.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"2519100","VIOLATION_NO":"9152034","ISSUE_DT":"08/25/2023","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"407.00","CURRENT_ASSESSMENT_AMT":"407.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-25"},{"SOURCE_ROW_NUMBER":"2519103","VIOLATION_NO":"9155448","ISSUE_DT":"08/02/2023","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"232.00","CURRENT_ASSESSMENT_AMT":"232.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-02"},{"SOURCE_ROW_NUMBER":"2519102","VIOLATION_NO":"9155447","ISSUE_DT":"08/01/2023","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"232.00","CURRENT_ASSESSMENT_AMT":"232.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-01"},{"SOURCE_ROW_NUMBER":"2519101","VIOLATION_NO":"9155446","ISSUE_DT":"07/24/2023","CFR_STANDARD_CD":"75.321(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"182.00","CURRENT_ASSESSMENT_AMT":"182.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-07-24"},{"SOURCE_ROW_NUMBER":"2519098","VIOLATION_NO":"9155436","ISSUE_DT":"06/26/2023","CFR_STANDARD_CD":"50.20(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-06-26"},{"SOURCE_ROW_NUMBER":"2519097","VIOLATION_NO":"9155428","ISSUE_DT":"04/27/2023","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"182.00","CURRENT_ASSESSMENT_AMT":"182.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-04-27"},{"SOURCE_ROW_NUMBER":"2519096","VIOLATION_NO":"9155427","ISSUE_DT":"04/20/2023","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"182.00","CURRENT_ASSESSMENT_AMT":"182.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-04-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":185,"firstDate":"2011-06-07","lastDate":"2023-02-22","metrics":{"appeals":0,"decisions":185,"recentRows":19,"decisionPenalty":193181,"originalPenalty":329888.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"435334","VIOLATION_NO":"9151771","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3080.00","DECISION_PENALTY_AMT":"357.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2023-02-22"},{"SOURCE_ROW_NUMBER":"434765","VIOLATION_NO":"9151760","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1358.00","DECISION_PENALTY_AMT":"1358.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2023-02-22"},{"SOURCE_ROW_NUMBER":"152268","VIOLATION_NO":"9155384","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"2025.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2023-02-22"},{"SOURCE_ROW_NUMBER":"152153","VIOLATION_NO":"9151767","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"295.20","DECISION_PENALTY_AMT":"328.00","JUDGE_FIRST_NAME":"Richard","JUDGE_LAST_NAME":"Manning","sourceDate":"2023-02-22"},{"SOURCE_ROW_NUMBER":"436249","VIOLATION_NO":"9155462","DOCKET_NO":"WEST 2022-0363","DECISION_DT":"02/03/2023","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1358.00","DECISION_PENALTY_AMT":"610.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2023-02-03"},{"SOURCE_ROW_NUMBER":"433426","VIOLATION_NO":"9151748","DOCKET_NO":"WEST 2022-0265","DECISION_DT":"12/19/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1156.00","DECISION_PENALTY_AMT":"1156.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2022-12-19"},{"SOURCE_ROW_NUMBER":"432913","VIOLATION_NO":"9151691","DOCKET_NO":"WEST 2022-0265","DECISION_DT":"12/19/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"17565.00","DECISION_PENALTY_AMT":"10000.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2022-12-19"},{"SOURCE_ROW_NUMBER":"151847","VIOLATION_NO":"9151687","DOCKET_NO":"WEST 2022-0265","DECISION_DT":"12/19/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1358.00","DECISION_PENALTY_AMT":"700.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2022-12-19"},{"SOURCE_ROW_NUMBER":"434258","VIOLATION_NO":"9155303","DOCKET_NO":"WEST 2022-0248","DECISION_DT":"09/13/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2376.00","DECISION_PENALTY_AMT":"1069.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2022-09-13"},{"SOURCE_ROW_NUMBER":"150860","VIOLATION_NO":"9154943","DOCKET_NO":"WEST 2022-0177","DECISION_DT":"06/17/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2025.00","DECISION_PENALTY_AMT":"2025.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2022-06-17"},{"SOURCE_ROW_NUMBER":"430031","VIOLATION_NO":"9151039","DOCKET_NO":"WEST 2021-0341","DECISION_DT":"02/07/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3917.00","DECISION_PENALTY_AMT":"3917.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2022-02-07"},{"SOURCE_ROW_NUMBER":"149120","VIOLATION_NO":"9151037","DOCKET_NO":"WEST 2021-0341","DECISION_DT":"02/07/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1759.00","DECISION_PENALTY_AMT":"177.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2022-02-07"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":8507,"firstDate":"2007-03-17","lastDate":"2023-10-18","metrics":{"recentRows":2279,"cpdmSamples":6110,"voidSamples":2915,"validSamples":5592,"maxConcentration":48505.726,"concentrationTotal":53474.968},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"744654","CASS_NUM":"58462924","SMP_TAKEN_DT":"10/18/2023","CONC":".089","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-10-18"},{"SOURCE_ROW_NUMBER":"709373","CASS_NUM":"58462836","SMP_TAKEN_DT":"10/18/2023","CONC":".046","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-10-18"},{"SOURCE_ROW_NUMBER":"584107","CASS_NUM":"58462984","SMP_TAKEN_DT":"10/18/2023","CONC":".021","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-10-18"},{"SOURCE_ROW_NUMBER":"766595","CASS_NUM":"51586137","SMP_TAKEN_DT":"9/12/2023","CONC":".235","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DA NOT IN PRODUCING STATUS","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-12"},{"SOURCE_ROW_NUMBER":"1217506","CASS_NUM":"58461893","SMP_TAKEN_DT":"9/8/2023","CONC":".258","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"1666346","CASS_NUM":"51572632","SMP_TAKEN_DT":"9/7/2023","CONC":".233","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DA NOT IN PRODUCING STATUS","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-07"},{"SOURCE_ROW_NUMBER":"336787","CASS_NUM":"51572652","SMP_TAKEN_DT":"9/7/2023","CONC":".116","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-07"},{"SOURCE_ROW_NUMBER":"911474","CASS_NUM":"51586310","SMP_TAKEN_DT":"9/6/2023","CONC":".093","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DA NOT IN PRODUCING STATUS","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-06"},{"SOURCE_ROW_NUMBER":"634671","CASS_NUM":"58472893","SMP_TAKEN_DT":"9/6/2023","CONC":".388","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-06"},{"SOURCE_ROW_NUMBER":"315182","CASS_NUM":"51586290","SMP_TAKEN_DT":"9/6/2023","CONC":".235","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DA NOT IN PRODUCING STATUS","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-06"},{"SOURCE_ROW_NUMBER":"201519","CASS_NUM":"58472895","SMP_TAKEN_DT":"9/6/2023","CONC":".173","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-06"},{"SOURCE_ROW_NUMBER":"105940","CASS_NUM":"58472898","SMP_TAKEN_DT":"9/6/2023","CONC":".041","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"FORKLIFT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2023-09-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":14,"firstDate":"2017-07-24","lastDate":"2022-10-28","metrics":{"linkedIssuances":14},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":185,"firstDate":"2009-09-28","lastDate":"2022-07-26","metrics":{"decisions":185,"ssChanged":34,"recentRows":15,"decisionPenalty":193181,"proposedPenalty":342043},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"47541","CITATION_NO":"9155462","CITATION_ISSUE_DT":"07/26/2022","DOCKET_NO":"WEST 2022-0363","DECISION_DT":"02/03/2023","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1358.00","DECISION_PENALTY_AMT":"610.00","sourceDate":"2022-07-26"},{"SOURCE_ROW_NUMBER":"389194","CITATION_NO":"9151771","CITATION_ISSUE_DT":"06/27/2022","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"14172.00","DECISION_PENALTY_AMT":"357.00","sourceDate":"2022-06-27"},{"SOURCE_ROW_NUMBER":"106219","CITATION_NO":"9151767","CITATION_ISSUE_DT":"06/22/2022","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1358.00","DECISION_PENALTY_AMT":"328.00","sourceDate":"2022-06-22"},{"SOURCE_ROW_NUMBER":"163523","CITATION_NO":"9155384","CITATION_ISSUE_DT":"06/21/2022","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2025.00","DECISION_PENALTY_AMT":".00","sourceDate":"2022-06-21"},{"SOURCE_ROW_NUMBER":"386439","CITATION_NO":"9151760","CITATION_ISSUE_DT":"06/03/2022","DOCKET_NO":"WEST 2022-0316","DECISION_DT":"02/22/2023","CFR_STANDARD_CODE":"75.601","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1358.00","DECISION_PENALTY_AMT":"1358.00","sourceDate":"2022-06-03"},{"SOURCE_ROW_NUMBER":"333308","CITATION_NO":"9151748","CITATION_ISSUE_DT":"04/20/2022","DOCKET_NO":"WEST 2022-0265","DECISION_DT":"12/19/2022","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1156.00","DECISION_PENALTY_AMT":"1156.00","sourceDate":"2022-04-20"},{"SOURCE_ROW_NUMBER":"160066","CITATION_NO":"9151691","CITATION_ISSUE_DT":"04/06/2022","DOCKET_NO":"WEST 2022-0265","DECISION_DT":"12/19/2022","CFR_STANDARD_CODE":"75.380(d)(7)(i)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"17565.00","DECISION_PENALTY_AMT":"10000.00","sourceDate":"2022-04-06"},{"SOURCE_ROW_NUMBER":"103708","CITATION_NO":"9151687","CITATION_ISSUE_DT":"04/06/2022","DOCKET_NO":"WEST 2022-0265","DECISION_DT":"12/19/2022","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1358.00","DECISION_PENALTY_AMT":"700.00","sourceDate":"2022-04-06"},{"SOURCE_ROW_NUMBER":"50748","CITATION_NO":"9155303","CITATION_ISSUE_DT":"03/22/2022","DOCKET_NO":"WEST 2022-0248","DECISION_DT":"09/13/2022","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2376.00","DECISION_PENALTY_AMT":"1069.00","sourceDate":"2022-03-22"},{"SOURCE_ROW_NUMBER":"102877","CITATION_NO":"9154943","CITATION_ISSUE_DT":"01/28/2022","DOCKET_NO":"WEST 2022-0177","DECISION_DT":"06/17/2022","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2025.00","DECISION_PENALTY_AMT":"2025.00","sourceDate":"2022-01-28"},{"SOURCE_ROW_NUMBER":"277061","CITATION_NO":"9151039","CITATION_ISSUE_DT":"07/13/2021","DOCKET_NO":"WEST 2021-0341","DECISION_DT":"02/07/2022","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3917.00","DECISION_PENALTY_AMT":"3917.00","sourceDate":"2021-07-13"},{"SOURCE_ROW_NUMBER":"50165","CITATION_NO":"9151037","CITATION_ISSUE_DT":"07/12/2021","DOCKET_NO":"WEST 2021-0341","DECISION_DT":"02/07/2022","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1759.00","DECISION_PENALTY_AMT":"177.00","sourceDate":"2021-07-12"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1483,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":344,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1999-02-24","lastDate":"2020-09-17","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":186,"firstDate":"2009-02-23","lastDate":"2024-07-23","metrics":{"inspectors":475,"recentRows":80,"onSiteHours":14617,"inspectionHours":22979,"inspectionSamples":2497},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"619005","EVENT_NO":"6469810","INSPECTION_BEGIN_DT":"07/23/2024","INSPECTION_END_DT":"07/23/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2024-07-23"},{"SOURCE_ROW_NUMBER":"785515","EVENT_NO":"F007B13","INSPECTION_BEGIN_DT":"06/26/2024","INSPECTION_END_DT":"06/27/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2024-06-26"},{"SOURCE_ROW_NUMBER":"937468","EVENT_NO":"6469731","INSPECTION_BEGIN_DT":"05/22/2024","INSPECTION_END_DT":"05/23/2024","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2024-05-22"},{"SOURCE_ROW_NUMBER":"218424","EVENT_NO":"6469842","INSPECTION_BEGIN_DT":"01/04/2024","INSPECTION_END_DT":"01/17/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"42","SUM_TOTAL_ON_SITE_HOURS":"21.5","sourceDate":"2024-01-04"},{"SOURCE_ROW_NUMBER":"658058","EVENT_NO":"6790953","INSPECTION_BEGIN_DT":"12/18/2023","INSPECTION_END_DT":"12/18/2023","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2023-12-18"},{"SOURCE_ROW_NUMBER":"898717","EVENT_NO":"6469901","INSPECTION_BEGIN_DT":"10/10/2023","INSPECTION_END_DT":"11/13/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"167.5","SUM_TOTAL_ON_SITE_HOURS":"103","sourceDate":"2023-10-10"},{"SOURCE_ROW_NUMBER":"727662","EVENT_NO":"6790945","INSPECTION_BEGIN_DT":"07/03/2023","INSPECTION_END_DT":"09/26/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"195","SUM_TOTAL_ON_SITE_HOURS":"122.5","sourceDate":"2023-07-03"},{"SOURCE_ROW_NUMBER":"344981","EVENT_NO":"6790942","INSPECTION_BEGIN_DT":"05/17/2023","INSPECTION_END_DT":"05/17/2023","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2023-05-17"},{"SOURCE_ROW_NUMBER":"804916","EVENT_NO":"6790940","INSPECTION_BEGIN_DT":"04/10/2023","INSPECTION_END_DT":"06/30/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"158","SUM_TOTAL_ON_SITE_HOURS":"93","sourceDate":"2023-04-10"},{"SOURCE_ROW_NUMBER":"1045628","EVENT_NO":"6469622","INSPECTION_BEGIN_DT":"04/05/2023","INSPECTION_END_DT":"04/05/2023","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2023-04-05"},{"SOURCE_ROW_NUMBER":"880018","EVENT_NO":"6463424","INSPECTION_BEGIN_DT":"02/21/2023","INSPECTION_END_DT":"03/30/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"173","SUM_TOTAL_ON_SITE_HOURS":"113.75","sourceDate":"2023-02-21"},{"SOURCE_ROW_NUMBER":"743544","EVENT_NO":"6463543","INSPECTION_BEGIN_DT":"11/02/2022","INSPECTION_END_DT":"12/12/2022","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"54","SUM_TOTAL_ON_SITE_HOURS":"30.75","sourceDate":"2022-11-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":192,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2024-Q4":{"hours":2916,"employees":6,"production":0},"2024-Q3":{"hours":2877,"employees":6,"production":0},"2024-Q2":{"hours":2967,"employees":7,"production":0},"2024-Q1":{"hours":19433,"employees":54,"production":0},"2023-Q4":{"hours":89352,"employees":148,"production":9141},"2023-Q3":{"hours":94902,"employees":152,"production":78168},"2023-Q2":{"hours":95942,"employees":155,"production":60546},"2023-Q1":{"hours":92009,"employees":146,"production":11385},"2022-Q4":{"hours":96484,"employees":166,"production":0},"2022-Q3":{"hours":149132,"employees":261,"production":680762},"2022-Q2":{"hours":153192,"employees":263,"production":652295},"2022-Q1":{"hours":141770,"employees":260,"production":948232}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":47,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015":{"hours":141707,"employees":65,"production":349570},"2016":{"hours":371814,"employees":157,"production":1586720},"2017":{"hours":346913,"employees":139,"production":1629311},"2018":{"hours":459205,"employees":207,"production":2630631},"2019":{"hours":625493,"employees":261,"production":3713971},"2020":{"hours":619984,"employees":266,"production":3301880},"2021":{"hours":583814,"employees":249,"production":3470644},"2022":{"hours":540578,"employees":294,"production":2281289},"2023":{"hours":372205,"employees":150,"production":159240},"2024":{"hours":28193,"employees":50,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":381,"firstDate":"2009-06-29","lastDate":"2023-09-08","metrics":{"recentRows":75,"doseOver100":45,"actDoseTotal":21423,"pelDoseTotal":13798},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"192320","EVENT_NO":"6790945","SURVEY_DATE":"09/08/2023","OCCUPATION_CD_DESC":"PUMPER","MACHINE_CD":"40","ACT_DOSE_85":"17","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"192319","EVENT_NO":"6790945","SURVEY_DATE":"09/08/2023","OCCUPATION_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","MACHINE_CD":"40","ACT_DOSE_85":"30","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"192318","EVENT_NO":"6790945","SURVEY_DATE":"09/08/2023","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"50","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"192317","EVENT_NO":"6790945","SURVEY_DATE":"09/08/2023","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","ACT_DOSE_85":"105","PEL_DOSE_90":"97","SURVEY_TYPE":"I","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"192316","EVENT_NO":"6790945","SURVEY_DATE":"09/08/2023","OCCUPATION_CD_DESC":"FIRE BOSS PRE-SHIFT EXAMINER","MACHINE_CD":"40","ACT_DOSE_85":"30","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"192315","EVENT_NO":"6790940","SURVEY_DATE":"05/31/2023","OCCUPATION_CD_DESC":"TIPPLE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"20","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2023-05-31"},{"SOURCE_ROW_NUMBER":"192314","EVENT_NO":"6790940","SURVEY_DATE":"05/31/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"30","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2023-05-31"},{"SOURCE_ROW_NUMBER":"192313","EVENT_NO":"6790940","SURVEY_DATE":"04/12/2023","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"90","PEL_DOSE_90":"66","SURVEY_TYPE":"I","sourceDate":"2023-04-12"},{"SOURCE_ROW_NUMBER":"192312","EVENT_NO":"6790940","SURVEY_DATE":"04/12/2023","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD SIDE)","MACHINE_CD":"37","ACT_DOSE_85":"35","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2023-04-12"},{"SOURCE_ROW_NUMBER":"192311","EVENT_NO":"6790940","SURVEY_DATE":"04/12/2023","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"86","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2023-04-12"},{"SOURCE_ROW_NUMBER":"192310","EVENT_NO":"6790940","SURVEY_DATE":"04/12/2023","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"40","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2023-04-12"},{"SOURCE_ROW_NUMBER":"192093","EVENT_NO":"6463424","SURVEY_DATE":"03/15/2023","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","ACT_DOSE_85":"53","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2023-03-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":356,"firstDate":"2009-06-23","lastDate":"2023-09-08","metrics":{"recentRows":80,"voidSamples":24,"maxQuartzPct":51.7,"validSamples":332,"quartzPctTotal":1494.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"6322","CASSETTE_NO":"58461893","SAMPLE_DT":"09/08/2023","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"3948","CASSETTE_NO":"58472893","SAMPLE_DT":"09/06/2023","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-09-06"},{"SOURCE_ROW_NUMBER":"161021","CASSETTE_NO":"58472907","SAMPLE_DT":"08/23/2023","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-08-23"},{"SOURCE_ROW_NUMBER":"86985","CASSETTE_NO":"58472901","SAMPLE_DT":"08/23/2023","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-08-23"},{"SOURCE_ROW_NUMBER":"7167","CASSETTE_NO":"58461902","SAMPLE_DT":"05/31/2023","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-05-31"},{"SOURCE_ROW_NUMBER":"105570","CASSETTE_NO":"58460725","SAMPLE_DT":"04/12/2023","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-04-12"},{"SOURCE_ROW_NUMBER":"2364","CASSETTE_NO":"58460726","SAMPLE_DT":"04/12/2023","QUARTZ_PCT":"04.4","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-04-12"},{"SOURCE_ROW_NUMBER":"157680","CASSETTE_NO":"58448080","SAMPLE_DT":"09/20/2022","QUARTZ_PCT":"00.3","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-20"},{"SOURCE_ROW_NUMBER":"58537","CASSETTE_NO":"58447878","SAMPLE_DT":"09/07/2022","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-07"},{"SOURCE_ROW_NUMBER":"33021","CASSETTE_NO":"58447877","SAMPLE_DT":"09/07/2022","QUARTZ_PCT":"00.9","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-07"},{"SOURCE_ROW_NUMBER":"23681","CASSETTE_NO":"58447879","SAMPLE_DT":"09/07/2022","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"SECTION FOREMAN","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-09-07"},{"SOURCE_ROW_NUMBER":"168275","CASSETTE_NO":"58447863","SAMPLE_DT":"08/17/2022","QUARTZ_PCT":"03.4","QUARTZ_MICROGRAMS":"22","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-08-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1551,"firstDate":"2009-05-05","lastDate":"2023-12-18","metrics":{"ss":124,"amountDue":606905,"contested":3,"amountPaid":578739,"recentRows":348,"section104d":1,"unterminated":0,"proposedPenalty":717483.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2259693","VIOLATION_NO":"9730503","VIOLATION_ISSUE_DT":"12/18/2023","SIG_SUB":"N","PART_SECTION":"77.1303(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/04/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2023-12-18"},{"SOURCE_ROW_NUMBER":"2259662","VIOLATION_NO":"9730533","VIOLATION_ISSUE_DT":"10/26/2023","SIG_SUB":"N","PART_SECTION":"75.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/26/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-10-26"},{"SOURCE_ROW_NUMBER":"2259661","VIOLATION_NO":"9730532","VIOLATION_ISSUE_DT":"10/18/2023","SIG_SUB":"N","PART_SECTION":"77.401(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/18/2023","PROPOSED_PENALTY":"155","AMOUNT_DUE":"155","AMOUNT_PAID":"155","CONTESTED_IND":"N","sourceDate":"2023-10-18"},{"SOURCE_ROW_NUMBER":"2259103","VIOLATION_NO":"9155457","VIOLATION_ISSUE_DT":"09/09/2023","SIG_SUB":"N","PART_SECTION":"75.380(d)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/09/2023","PROPOSED_PENALTY":"518","AMOUNT_DUE":"518","AMOUNT_PAID":"518","CONTESTED_IND":"N","sourceDate":"2023-09-09"},{"SOURCE_ROW_NUMBER":"2259102","VIOLATION_NO":"9155456","VIOLATION_ISSUE_DT":"09/08/2023","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2023","PROPOSED_PENALTY":"198","AMOUNT_DUE":"198","AMOUNT_PAID":"198","CONTESTED_IND":"N","sourceDate":"2023-09-08"},{"SOURCE_ROW_NUMBER":"2259098","VIOLATION_NO":"9152034","VIOLATION_ISSUE_DT":"08/25/2023","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/15/2023","PROPOSED_PENALTY":"407","AMOUNT_DUE":"407","AMOUNT_PAID":"407","CONTESTED_IND":"N","sourceDate":"2023-08-25"},{"SOURCE_ROW_NUMBER":"2259101","VIOLATION_NO":"9155448","VIOLATION_ISSUE_DT":"08/02/2023","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/22/2023","PROPOSED_PENALTY":"232","AMOUNT_DUE":"232","AMOUNT_PAID":"232","CONTESTED_IND":"N","sourceDate":"2023-08-02"},{"SOURCE_ROW_NUMBER":"2259100","VIOLATION_NO":"9155447","VIOLATION_ISSUE_DT":"08/01/2023","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/02/2023","PROPOSED_PENALTY":"232","AMOUNT_DUE":"232","AMOUNT_PAID":"232","CONTESTED_IND":"N","sourceDate":"2023-08-01"},{"SOURCE_ROW_NUMBER":"2259099","VIOLATION_NO":"9155446","VIOLATION_ISSUE_DT":"07/24/2023","SIG_SUB":"N","PART_SECTION":"75.321(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/31/2023","PROPOSED_PENALTY":"182","AMOUNT_DUE":"182","AMOUNT_PAID":"182","CONTESTED_IND":"N","sourceDate":"2023-07-24"},{"SOURCE_ROW_NUMBER":"2258849","VIOLATION_NO":"9155436","VIOLATION_ISSUE_DT":"06/26/2023","SIG_SUB":"N","PART_SECTION":"50.20(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/26/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-06-26"},{"SOURCE_ROW_NUMBER":"2258848","VIOLATION_NO":"9155428","VIOLATION_ISSUE_DT":"04/27/2023","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/28/2023","PROPOSED_PENALTY":"182","AMOUNT_DUE":"182","AMOUNT_PAID":"182","CONTESTED_IND":"N","sourceDate":"2023-04-27"},{"SOURCE_ROW_NUMBER":"2258847","VIOLATION_NO":"9155427","VIOLATION_ISSUE_DT":"04/20/2023","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/21/2023","PROPOSED_PENALTY":"182","AMOUNT_DUE":"182","AMOUNT_PAID":"182","CONTESTED_IND":"N","sourceDate":"2023-04-20"}]}],"safety":{"href":"/api/v1/mines/4202241/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4202241/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1303","heading":"Explosives, handling and use.","id":"77.1303","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-N/section-77.1303","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"N","subpartHeading":"Subpart N—Explosives and Blasting","text":"(a) Persons who use or handle explosives or detonators shall be experienced men who understand the hazards involved; trainees shall do such work only under the supervision of and in the immediate presence of experienced men.\n\n(b) Blasting operations shall be under the direct control of authorized persons.\n\n(c) Substantial nonconductive closed containers shall be used to carry explosives, other than blasting agents to the blasting site.\n\n(d) Damaged or deteriorated explosives or detonators shall be destroyed in a safe manner.\n\n(e) Where electric blasting is to be performed, electric circuits to equipment in the immediate area to be blasted shall be deenergized before explosives or detonators are brought into the area; the power shall not be turned on again until after the shots are fired.\n\n(f) Explosives shall be kept separated from detonators until charging is started.\n\n(g) Areas in which charged holes are awaiting firing shall be guarded, or barricaded and posted, or flagged against unauthorized entry.\n\n(h) Ample warning shall be given before blasts are fired. All persons shall be cleared and removed from the blasting area unless suitable blasting shelters are provided to protect men endangered by concussion or flyrock from blasting.\n\n(i) Lead wires and blasting lines shall not be strung across power conductors, pipelines, railroad tracks, or within 20 feet of bare powerlines. They shall be protected from sources of static or other electrical contact.\n\n(j) For the protection of underground workers, special precautions shall be taken when blasting in close proximity to underground operations, and no blasting shall be done that would be hazardous to persons working underground.\n\n(k) Holes shall not be drilled where there is danger of intersecting a charged or misfired hole.\n\n(l) Only wooden or other nonsparking implements shall be used to punch holes in an explosive cartridge.\n\n(m) Tamping poles shall be blunt and squared at one end and made of wood, nonsparking material, or of special plastic acceptable to the Mine Safety and Health Administration.\n\n(n) Delay connectors for firing detonating cord shall be treated and handled with the same safety precautions as blasting caps and electric detonators.\n\n(o) Capped primers shall be made up at the time of charging and as close to the blasting site as conditions allow.\n\n(p) A capped primer shall be prepared so that the detonator is contained securely and is completely embedded within the explosive cartridge.\n\n(q) No tamping shall be done directly on a capped primer.\n\n(r) Detonating cord shall not be used if it has been kinked, bent, or otherwise handled in such a manner that the train of detonation may be interrupted.\n\n(s) Fuse shall not be used if it has been kinked, bent sharply, or handled roughly in such a manner that the train of deflagration may be interrupted.\n\n(t) Blasting caps shall be crimped to fuses only with implements designed for that specific purpose.\n\n(u) When firing from 1 to 15 blast-holes with safety fuse ignited individually using hand-held lighters, the fuses shall be of such lengths to provide the minimum burning time specified in the following table for a particular size round:\n\nNumber of holes in a round Minimum burning time, minutes 1 2 2 to 5 22⁄3 6 to 10 31⁄3 11 to 15 5\n\nIn no case shall any 40-second-per-foot safety fuse less than 36 inches long or any 30-second-per-foot safety fuse less than 48 inches long be used.\n\n(v) The burning rate of the safety fuse in use at any time shall be measured, posted in conspicuous locations, and brought to the attention of all men concerned with blasting.\n\n(w) Electric detonators of different brands shall not be used in the same round.\n\n(x) Adequate priming shall be employed to guard against misfires, increased toxic fumes, and poor performance.\n\n(y) Except when being tested with a blasting galvanometer:\n\n(1) Electric detonators shall be kept shunted until they are being connected to the blasting line or wired into a blasting round.\n\n(2) Wired rounds shall be kept shunted until they are being connected to the blasting line.\n\n(3) Blasting lines shall be kept shunted until immediately before blasting.\n\n(z) Completely wired rounds shall be tested with a blasting galvanometer before connections are made to the blasting line.\n\n(aa) Permanent blasting lines shall be properly supported, insulated, and kept in good repair.\n\n(bb) At least a 5-foot airgap shall be provided between the blasting circuit and the power circuit.\n\n(cc) When instantaneous blasting is performed, the double-trunkline or loop system shall be used in detonating-cord blasting.\n\n(dd) When instantaneous blasting is performed, trunklines, in multiple-row blasts, shall make one or more complete loops, with crossties between loops at intervals of not over 200 feet.\n\n(ee) All detonating cord knots shall be tight and all connections shall be kept at right angles to the trunklines.\n\n(ff) Power sources shall be suitable for the number of electrical detonators to be fired and for the type of circuits used.\n\n(gg) Electric circuits from the blasting switches to the blast area shall not be grounded.\n\n(hh) Safety switches and blasting switches shall be labeled, encased in boxes, and arranged so that the covers of the boxes cannot be closed with the switches in the through-circuit or firing position.\n\n(ii) Blasting switches shall be locked in the open position, except when closed to fire the blast. Lead wires shall not be connected to the blasting switch until the shot is ready to be fired.\n\n(jj) The key or other control to an electrical firing device shall be entrusted only to the person designated to fire the round or rounds.\n\n(kk) If branch circuits are used when blasts are fired from power circuits, safety switches located at safe distances from the blast areas shall be provided in addition to the main blasting switch.\n\n(ll) Misfires shall be reported to the proper supervisor and shall be disposed of safely before any other work is performed in that blasting area.\n\n(mm) When safety fuse has been used, men shall not return to misfired holes for at least 30 minutes.\n\n(nn) When electric blasting caps have been used, men shall not return to misfired holes for at least 15 minutes.\n\n(oo) If explosives are suspected of burning in a hole, all persons in the endangered area shall move to a safe location and no one should return to the hole until the danger has passed, but in no case within 1 hour.\n\n(pp) Blasted areas shall be examined for undetonated explosives after each blast and undetonated explosives found shall be disposed of safely.\n\n(qq) Blasted areas shall not be reentered by any person after firing until such time as concentrations of smoke, dust, or fumes have been reduced to safe limits.\n\n(rr) In secondary blasting, if more than one shot is to be fired at one time, blasting shall be done electrically or with detonating cord.\n\n(ss) Unused explosives and detonators shall be moved to a safe location as soon as charging operations are completed.\n\n(tt) When electric detonators are used, charging shall be stopped immediately when the presence of static electricity or stray currents is detected; the condition shall be remedied before charging is resumed.\n\n(uu) When electric detonators are used, charging shall be suspended and men withdrawn to a safe location upon the approach of an electrical storm.","occurrenceCount":1},{"chapter":"I","heading":"Underground storage, lubricating oil and grease.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1104","part":"75","subchapter":"O","subpart":"L","id":"75.1104","citation":"30 CFR 75.1104","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Stationary grinding machines; protective devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.401","part":"77","subchapter":"O","subpart":"E","id":"77.401","citation":"30 CFR 77.401","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.321","heading":"Air quality.","id":"75.321","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.321","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The air in areas where persons work or travel, except as specified in paragraph (a)(2) of this section, shall contain at least 19.5 percent oxygen and not more than 0.5 percent carbon dioxide, and the volume and velocity of the air current in these areas shall be sufficient to dilute, render harmless, and carry away flammable, explosive, noxious, and harmful gases, dusts, smoke, and fumes.\n\n(2) The air in areas of bleeder entries and worked-out areas where persons work or travel shall contain at least 19.5 percent oxygen, and carbon dioxide levels shall not exceed 0.5 percent time weighted average and 3.0 percent short term exposure limit.\n\n(b) Notwithstanding the provisions of § 75.322, for the purpose of preventing explosions from gases other than methane, the following gases shall not be permitted to accumulate in excess of the concentrations listed below:\n\n(1) Carbon monoxide (CO)—2.5 percent\n\n(2) Hydrogen (H2)—.80 percent\n\n(3) Hydrogen sulfide (H2 S)—.80 percent\n\n(4) Acetylene (C2 H2)—.40 percent\n\n(5) Propane (C3 H8)—.40 percent\n\n(6) MAPP (methyl-acetylene-propylene-propodiene)—.30 percent","occurrenceCount":1},{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4202241","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}