{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"4202238","name":"DTE Utah Synfuels LLC","status":"Abandoned","status_date":"2008-06-16","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"UT","county":"Carbon","nearest_town":"Price","operator_id":"0069523","operator_name":"DTE Utah Synfuels LLC","controller_id":"C15950","controller_name":"DTE Energy Company","district":"C09","office":"Price UT Field Office","employees":0,"latitude":39.535,"longitude":-110.776944},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":295},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4202238","name":"DTE Utah Synfuels LLC"},"operator":{"type":"operator","id":"0069523","name":"DTE Utah Synfuels LLC"},"controller":{"type":"controller","id":"C15950","name":"DTE Energy Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15639","name":"Brent M  Cook"},"object":{"type":"mine","id":"4202238","name":"DTE Utah Synfuels LLC"},"validFrom":"1999-02-01","validTo":"2002-12-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|C15639|1999-02-01|2002-12-01"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24539","name":"Headwaters Inc"},"object":{"type":"mine","id":"4202238","name":"DTE Utah Synfuels LLC"},"validFrom":"1999-03-01","validTo":"2005-11-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|P24539|1999-03-01|2005-11-01"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15639","name":"Brent M  Cook"},"object":{"type":"operator","id":"P24539","name":"Headwaters Inc"},"validFrom":"1999-03-01","validTo":"2002-12-01","current":false,"derived":true,"evidenceMineId":"4202238","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|P24539|1999-03-01|C15639|1999-02-01|96420"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041435","name":"Kirk A  Benson et al"},"object":{"type":"mine","id":"4202238","name":"DTE Utah Synfuels LLC"},"validFrom":"2002-12-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|0041435|2002-12-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041435","name":"Kirk A  Benson et al"},"object":{"type":"operator","id":"P24539","name":"Headwaters Inc"},"validFrom":"2002-12-02","validTo":"2005-11-01","current":false,"derived":true,"evidenceMineId":"4202238","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|P24539|1999-03-01|0041435|2002-12-02|2591"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0069523","name":"DTE Utah Synfuels LLC"},"object":{"type":"mine","id":"4202238","name":"DTE Utah Synfuels LLC"},"validFrom":"2005-11-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|0069523|2005-11-02|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15950","name":"DTE Energy Company"},"object":{"type":"mine","id":"4202238","name":"DTE Utah Synfuels LLC"},"validFrom":"2005-11-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|C15950|2005-11-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15950","name":"DTE Energy Company"},"object":{"type":"operator","id":"0069523","name":"DTE Utah Synfuels LLC"},"validFrom":"2005-11-02","validTo":null,"current":true,"derived":true,"evidenceMineId":"4202238","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"4202238|0069523|2005-11-02|C15950|2005-11-02|97817"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2006-02-07","lastDate":"2006-02-07","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"196596","DOCUMENT_NO":"220060870005","ACCIDENT_DT":"02/07/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured employee was sweeping the floor and stepped on a piece of coal which caused his right leg to slip from under him, twisting his knee.  Initially the injury received only first aid level treatment.  Knee pain persisted and the employee returned to the doctor.  The doctor the diagnosed a possible torn meniscus in the knee and ordered a surgical scope of the knee.","sourceDate":"2006-02-07"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2008-06-16","lastDate":"2008-06-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":6,"firstDate":"2004-06-17","lastDate":"2007-04-12","metrics":{"ss":2,"delinquent":5,"recentRows":0,"paidPenalty":411,"proposedPenalty":411,"currentAssessment":411},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1509664","VIOLATION_NO":"7287203","ISSUE_DT":"04/12/2007","CFR_STANDARD_CD":"77.1710(i)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-12"},{"SOURCE_ROW_NUMBER":"1509763","VIOLATION_NO":"7287012","ISSUE_DT":"01/22/2007","CFR_STANDARD_CD":"77.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"1509762","VIOLATION_NO":"7286906","ISSUE_DT":"01/22/2007","CFR_STANDARD_CD":"77.202","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"1509761","VIOLATION_NO":"7286905","ISSUE_DT":"01/22/2007","CFR_STANDARD_CD":"77.202","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"1509760","VIOLATION_NO":"7286904","ISSUE_DT":"01/22/2007","CFR_STANDARD_CD":"77.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"99.00","CURRENT_ASSESSMENT_AMT":"99.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"1238497","VIOLATION_NO":"7616616","ISSUE_DT":"06/17/2004","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-06-17"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":42,"firstDate":"2002-01-15","lastDate":"2007-04-13","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":41,"maxConcentration":0.73,"concentrationTotal":7.363},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1512541","CASS_NUM":"57665277","SMP_TAKEN_DT":"4/13/2007","CONC":".73","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"FINE COAL PLANT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-13"},{"SOURCE_ROW_NUMBER":"1459516","CASS_NUM":"57665279","SMP_TAKEN_DT":"4/13/2007","CONC":".201","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-13"},{"SOURCE_ROW_NUMBER":"1269313","CASS_NUM":"57665276","SMP_TAKEN_DT":"4/13/2007","CONC":".044","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-13"},{"SOURCE_ROW_NUMBER":"795064","CASS_NUM":"57665265","SMP_TAKEN_DT":"4/13/2007","CONC":".106","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-13"},{"SOURCE_ROW_NUMBER":"71554","CASS_NUM":"57665280","SMP_TAKEN_DT":"4/13/2007","CONC":".265","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-13"},{"SOURCE_ROW_NUMBER":"1341830","CASS_NUM":"57675191","SMP_TAKEN_DT":"1/30/2007","CONC":".132","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROTARY DUMP OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-30"},{"SOURCE_ROW_NUMBER":"1216323","CASS_NUM":"57675195","SMP_TAKEN_DT":"1/30/2007","CONC":".288","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"MALFUNCTIONING PUMP","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-30"},{"SOURCE_ROW_NUMBER":"1211313","CASS_NUM":"57675192","SMP_TAKEN_DT":"1/30/2007","CONC":".028","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROTARY DUMP OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-30"},{"SOURCE_ROW_NUMBER":"793395","CASS_NUM":"57675194","SMP_TAKEN_DT":"1/30/2007","CONC":".194","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-30"},{"SOURCE_ROW_NUMBER":"630196","CASS_NUM":"57675190","SMP_TAKEN_DT":"1/30/2007","CONC":".034","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROTARY DUMP OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-30"},{"SOURCE_ROW_NUMBER":"561441","CASS_NUM":"57675193","SMP_TAKEN_DT":"1/30/2007","CONC":".383","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-30"},{"SOURCE_ROW_NUMBER":"384840","CASS_NUM":"57675196","SMP_TAKEN_DT":"1/30/2007","CONC":".297","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-01-30"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":127,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":27,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1999-03-01","lastDate":"2005-11-02","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":25,"firstDate":"2001-07-02","lastDate":"2008-03-17","metrics":{"inspectors":27,"recentRows":0,"onSiteHours":195.75,"inspectionHours":279.5,"inspectionSamples":19},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1058910","EVENT_NO":"4478585","INSPECTION_BEGIN_DT":"03/17/2008","INSPECTION_END_DT":"03/17/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2008-03-17"},{"SOURCE_ROW_NUMBER":"1157142","EVENT_NO":"4476452","INSPECTION_BEGIN_DT":"04/10/2007","INSPECTION_END_DT":"04/16/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"28","SUM_TOTAL_ON_SITE_HOURS":"17","sourceDate":"2007-04-10"},{"SOURCE_ROW_NUMBER":"1112995","EVENT_NO":"4476463","INSPECTION_BEGIN_DT":"01/22/2007","INSPECTION_END_DT":"02/05/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"53.5","SUM_TOTAL_ON_SITE_HOURS":"32.5","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"75868","EVENT_NO":"4474203","INSPECTION_BEGIN_DT":"03/24/2006","INSPECTION_END_DT":"03/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"12.75","sourceDate":"2006-03-24"},{"SOURCE_ROW_NUMBER":"906600","EVENT_NO":"4271619","INSPECTION_BEGIN_DT":"04/17/2005","INSPECTION_END_DT":"04/29/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-04-17"},{"SOURCE_ROW_NUMBER":"812873","EVENT_NO":"4271618","INSPECTION_BEGIN_DT":"04/17/2005","INSPECTION_END_DT":"04/18/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2005-04-17"},{"SOURCE_ROW_NUMBER":"477616","EVENT_NO":"4271686","INSPECTION_BEGIN_DT":"02/27/2005","INSPECTION_END_DT":"03/08/2005","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-02-27"},{"SOURCE_ROW_NUMBER":"185901","EVENT_NO":"4271687","INSPECTION_BEGIN_DT":"02/27/2005","INSPECTION_END_DT":"02/27/2005","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2005-02-27"},{"SOURCE_ROW_NUMBER":"28838","EVENT_NO":"4271685","INSPECTION_BEGIN_DT":"02/24/2005","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"17.5","sourceDate":"2005-02-24"},{"SOURCE_ROW_NUMBER":"836383","EVENT_NO":"4271556","INSPECTION_BEGIN_DT":"06/17/2004","INSPECTION_END_DT":"06/18/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"37649","EVENT_NO":"4271555","INSPECTION_BEGIN_DT":"06/17/2004","INSPECTION_END_DT":"06/17/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2004-06-17"},{"SOURCE_ROW_NUMBER":"580944","EVENT_NO":"4271548","INSPECTION_BEGIN_DT":"04/01/2004","INSPECTION_END_DT":"06/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2004-04-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":10652,"employees":21,"production":0},"2002-Q3":{"hours":9793,"employees":21,"production":0},"2002-Q2":{"hours":11887,"employees":24,"production":0},"2002-Q1":{"hours":10921,"employees":24,"production":0},"2001-Q4":{"hours":9728,"employees":22,"production":0},"2001-Q3":{"hours":5065,"employees":12,"production":0},"2001-Q2":{"hours":200,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":14993,"employees":13,"production":0},"2002":{"hours":43253,"employees":23,"production":0},"2003":{"hours":36207,"employees":16,"production":0},"2004":{"hours":22703,"employees":12,"production":0},"2005":{"hours":49834,"employees":24,"production":0},"2006":{"hours":47078,"employees":24,"production":0},"2007":{"hours":47604,"employees":24,"production":0},"2008":{"hours":1920,"employees":24,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":27,"firstDate":"2002-01-16","lastDate":"2007-01-29","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":696,"pelDoseTotal":377},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"192017","EVENT_NO":"4476463","SURVEY_DATE":"01/29/2007","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"26","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"192016","EVENT_NO":"4476463","SURVEY_DATE":"01/29/2007","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"62","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"192015","EVENT_NO":"4476463","SURVEY_DATE":"01/29/2007","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"20","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"192014","EVENT_NO":"4476463","SURVEY_DATE":"01/29/2007","OCCUPATION_CD_DESC":"SCOOP OPERATOR","MACHINE_CD":"24","MANUFACTURER_CD":"018","ACT_DOSE_85":"16","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"192013","EVENT_NO":"4476463","SURVEY_DATE":"01/29/2007","OCCUPATION_CD_DESC":"SCOOP OPERATOR","MACHINE_CD":"24","MANUFACTURER_CD":"018","ACT_DOSE_85":"7","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"192012","EVENT_NO":"4476463","SURVEY_DATE":"01/29/2007","OCCUPATION_CD_DESC":"TIPPLE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"30","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"192011","EVENT_NO":"4476463","SURVEY_DATE":"01/29/2007","OCCUPATION_CD_DESC":"SCOOP OPERATOR","MACHINE_CD":"24","MANUFACTURER_CD":"018","ACT_DOSE_85":"10","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2007-01-29"},{"SOURCE_ROW_NUMBER":"192010","EVENT_NO":"4271687","SURVEY_DATE":"02/27/2005","OCCUPATION_CD_DESC":"PREPARATION PLANT FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"35","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2005-02-27"},{"SOURCE_ROW_NUMBER":"192009","EVENT_NO":"4271687","SURVEY_DATE":"02/27/2005","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"27","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2005-02-27"},{"SOURCE_ROW_NUMBER":"192008","EVENT_NO":"4271687","SURVEY_DATE":"02/27/2005","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"28","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2005-02-27"},{"SOURCE_ROW_NUMBER":"192007","EVENT_NO":"4271687","SURVEY_DATE":"02/27/2005","OCCUPATION_CD_DESC":"SCOOP OPERATOR","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2005-02-27"},{"SOURCE_ROW_NUMBER":"192006","EVENT_NO":"4271687","SURVEY_DATE":"02/27/2005","OCCUPATION_CD_DESC":"SCOOP OPERATOR","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"22","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2005-02-27"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":6,"firstDate":"2004-06-17","lastDate":"2007-04-12","metrics":{"ss":2,"amountDue":411,"contested":0,"amountPaid":411,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":411},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2259001","VIOLATION_NO":"7287203","VIOLATION_ISSUE_DT":"04/12/2007","SIG_SUB":"Y","PART_SECTION":"77.1710(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/12/2007","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"72","CONTESTED_IND":"N","sourceDate":"2007-04-12"},{"SOURCE_ROW_NUMBER":"2258999","VIOLATION_NO":"7287012","VIOLATION_ISSUE_DT":"01/22/2007","SIG_SUB":"N","PART_SECTION":"77.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/22/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"2258998","VIOLATION_NO":"7286906","VIOLATION_ISSUE_DT":"01/22/2007","SIG_SUB":"N","PART_SECTION":"77.202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"2258997","VIOLATION_NO":"7286905","VIOLATION_ISSUE_DT":"01/22/2007","SIG_SUB":"N","PART_SECTION":"77.202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"2258996","VIOLATION_NO":"7286904","VIOLATION_ISSUE_DT":"01/22/2007","SIG_SUB":"Y","PART_SECTION":"77.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2007","PROPOSED_PENALTY":"99","AMOUNT_DUE":"99","AMOUNT_PAID":"99","CONTESTED_IND":"N","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"2259000","VIOLATION_NO":"7616616","VIOLATION_ISSUE_DT":"06/17/2004","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/17/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-06-17"}]}],"safety":{"href":"/api/v1/mines/4202238/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4202238/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Identification of circuit breakers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.904","part":"77","subchapter":"O","subpart":"J","id":"77.904","citation":"30 CFR 77.904","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Dust accumulations in surface installations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.202","part":"77","subchapter":"O","subpart":"C","id":"77.202","citation":"30 CFR 77.202","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4202238","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}