{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4003273","name":"Watson Branch","status":"Abandoned and Sealed","status_date":"2023-11-06","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"TN","county":"Claiborne","nearest_town":"Clairfield","operator_id":"0051382","operator_name":"Solid Fuel, Inc.","controller_id":"C12755","controller_name":"Darrell  Wagner","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.573611,"longitude":-83.7775},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":2648},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4003273","name":"Watson Branch"},"operator":{"type":"operator","id":"0051382","name":"Solid Fuel, Inc."},"controller":{"type":"controller","id":"C12755","name":"Darrell  Wagner"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15892","name":"Jackie (Mitch)  Fannin Et Al"},"object":{"type":"mine","id":"4003273","name":"Watson Branch"},"validFrom":"1998-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|C15892|1998-02-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041895","name":"Wilma  Wagner"},"object":{"type":"mine","id":"4003273","name":"Watson Branch"},"validFrom":"2003-04-23","validTo":"2011-08-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|0041895|2003-04-23|2011-08-11"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23841","name":"Tennco, Inc."},"object":{"type":"mine","id":"4003273","name":"Watson Branch"},"validFrom":"2006-02-03","validTo":"2012-01-02","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|P23841|2006-02-03|2012-01-02"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15892","name":"Jackie (Mitch)  Fannin Et Al"},"object":{"type":"operator","id":"P23841","name":"Tennco, Inc."},"validFrom":"2006-02-03","validTo":"2012-01-02","current":false,"derived":true,"evidenceMineId":"4003273","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|P23841|2006-02-03|C15892|1998-02-01|97484"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15892","name":"Jack  Stump Et Al"},"object":{"type":"operator","id":"P23841","name":"Tennco, Inc."},"validFrom":"2006-02-03","validTo":"2012-01-02","current":false,"derived":true,"evidenceMineId":"4003273","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|P23841|2006-02-03|C15892|1998-02-01|97485"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12755","name":"Darrell  Wagner"},"object":{"type":"mine","id":"4003273","name":"Watson Branch"},"validFrom":"2011-08-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|C12755|2011-08-12|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051382","name":"Solid Fuel, Inc."},"object":{"type":"mine","id":"4003273","name":"Watson Branch"},"validFrom":"2012-01-03","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|0051382|2012-01-03|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041895","name":"Wilma  Wagner"},"object":{"type":"operator","id":"0051382","name":"Solid Fuel, Inc."},"validFrom":"2012-01-03","validTo":"2011-08-11","current":false,"derived":true,"evidenceMineId":"4003273","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|0051382|2012-01-03|0041895|2003-04-23|3260"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12755","name":"Darrell  Wagner"},"object":{"type":"operator","id":"0051382","name":"Solid Fuel, Inc."},"validFrom":"2012-01-03","validTo":null,"current":true,"derived":true,"evidenceMineId":"4003273","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003273|0051382|2012-01-03|C12755|2011-08-12|87814"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2017-10-10","lastDate":"2017-10-10","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":20,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3034","DOCUMENT_NO":"220181410002","ACCIDENT_DT":"10/10/2017","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While an ee was using a hammer & chisel to break chain apart another ee was observing. A small sliver of metal hit that ee in left wrist.","sourceDate":"2017-10-10"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2023-11-06","lastDate":"2023-11-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":687,"firstDate":"2006-05-09","lastDate":"2018-12-18","metrics":{"ss":160,"delinquent":683,"recentRows":0,"paidPenalty":92125.43,"proposedPenalty":211892,"currentAssessment":211892},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1480753","VIOLATION_NO":"9133090","ISSUE_DT":"12/18/2018","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"4227.00","CURRENT_ASSESSMENT_AMT":"4227.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-12-18"},{"SOURCE_ROW_NUMBER":"1473814","VIOLATION_NO":"9133024","ISSUE_DT":"05/21/2018","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-05-21"},{"SOURCE_ROW_NUMBER":"1480650","VIOLATION_NO":"9133021","ISSUE_DT":"05/09/2018","CFR_STANDARD_CD":"50.20(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-05-09"},{"SOURCE_ROW_NUMBER":"1473645","VIOLATION_NO":"8372568","ISSUE_DT":"01/23/2018","CFR_STANDARD_CD":"75.311(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-01-23"},{"SOURCE_ROW_NUMBER":"1473103","VIOLATION_NO":"8372564","ISSUE_DT":"12/05/2017","CFR_STANDARD_CD":"75.512-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-12-05"},{"SOURCE_ROW_NUMBER":"1473102","VIOLATION_NO":"8372563","ISSUE_DT":"11/21/2017","CFR_STANDARD_CD":"75.1100-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-11-21"},{"SOURCE_ROW_NUMBER":"1473101","VIOLATION_NO":"8372562","ISSUE_DT":"11/16/2017","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"577.00","CURRENT_ASSESSMENT_AMT":"577.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-11-16"},{"SOURCE_ROW_NUMBER":"1473100","VIOLATION_NO":"8372561","ISSUE_DT":"11/16/2017","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-11-16"},{"SOURCE_ROW_NUMBER":"1473099","VIOLATION_NO":"8372560","ISSUE_DT":"11/16/2017","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-11-16"},{"SOURCE_ROW_NUMBER":"1473112","VIOLATION_NO":"8842079","ISSUE_DT":"10/30/2017","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"467.00","CURRENT_ASSESSMENT_AMT":"467.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-10-30"},{"SOURCE_ROW_NUMBER":"1473111","VIOLATION_NO":"8842078","ISSUE_DT":"10/30/2017","CFR_STANDARD_CD":"75.402","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"420.00","CURRENT_ASSESSMENT_AMT":"420.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-10-30"},{"SOURCE_ROW_NUMBER":"1473110","VIOLATION_NO":"8842077","ISSUE_DT":"10/30/2017","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"533.00","CURRENT_ASSESSMENT_AMT":"533.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-10-30"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":675,"firstDate":"2006-05-18","lastDate":"2017-11-22","metrics":{"recentRows":0,"cpdmSamples":251,"voidSamples":202,"validSamples":473,"maxConcentration":4.546,"concentrationTotal":262.052},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2788328","SMP_TAKEN_DT":"11/22/2017","CONC":".101","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-22"},{"SOURCE_ROW_NUMBER":"1936068","SMP_TAKEN_DT":"11/22/2017","CONC":".034","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Sample Transmitted Late","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-22"},{"SOURCE_ROW_NUMBER":"2106774","SMP_TAKEN_DT":"11/21/2017","CONC":".379","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-21"},{"SOURCE_ROW_NUMBER":"2276958","SMP_TAKEN_DT":"11/16/2017","CONC":".612","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"OPERATOR VOID; MISC.","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-16"},{"SOURCE_ROW_NUMBER":"2276805","SMP_TAKEN_DT":"11/15/2017","CONC":".019","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-15"},{"SOURCE_ROW_NUMBER":"1680688","SMP_TAKEN_DT":"11/15/2017","CONC":".685","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-15"},{"SOURCE_ROW_NUMBER":"2447624","SMP_TAKEN_DT":"11/14/2017","CONC":".793","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-14"},{"SOURCE_ROW_NUMBER":"1936428","SMP_TAKEN_DT":"11/14/2017","CONC":".247","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-14"},{"SOURCE_ROW_NUMBER":"2703220","SMP_TAKEN_DT":"11/13/2017","CONC":".102","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-13"},{"SOURCE_ROW_NUMBER":"2020693","SMP_TAKEN_DT":"11/13/2017","CONC":".378","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-13"},{"SOURCE_ROW_NUMBER":"2106614","SMP_TAKEN_DT":"11/12/2017","CONC":".083","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-12"},{"SOURCE_ROW_NUMBER":"2617789","SMP_TAKEN_DT":"11/11/2017","CONC":".166","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-11-11"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":13,"firstDate":"2012-10-09","lastDate":"2017-04-20","metrics":{"linkedIssuances":13},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":179,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":49,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2006-02-03","lastDate":"2012-01-03","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":112,"firstDate":"2006-02-27","lastDate":"2020-04-09","metrics":{"inspectors":233,"recentRows":0,"onSiteHours":3615,"inspectionHours":6155,"inspectionSamples":709},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"600202","EVENT_NO":"4459645","INSPECTION_BEGIN_DT":"04/09/2020","INSPECTION_END_DT":"04/09/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2020-04-09"},{"SOURCE_ROW_NUMBER":"608872","EVENT_NO":"4459489","INSPECTION_BEGIN_DT":"02/05/2020","INSPECTION_END_DT":"02/05/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2020-02-05"},{"SOURCE_ROW_NUMBER":"108103","EVENT_NO":"4459487","INSPECTION_BEGIN_DT":"11/26/2019","INSPECTION_END_DT":"11/26/2019","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2019-11-26"},{"SOURCE_ROW_NUMBER":"300762","EVENT_NO":"4456964","INSPECTION_BEGIN_DT":"08/02/2019","INSPECTION_END_DT":"08/02/2019","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2019-08-02"},{"SOURCE_ROW_NUMBER":"877298","EVENT_NO":"4457570","INSPECTION_BEGIN_DT":"04/08/2019","INSPECTION_END_DT":"04/08/2019","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2019-04-08"},{"SOURCE_ROW_NUMBER":"188620","EVENT_NO":"4456908","INSPECTION_BEGIN_DT":"02/20/2019","INSPECTION_END_DT":"02/20/2019","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2019-02-20"},{"SOURCE_ROW_NUMBER":"888045","EVENT_NO":"4456903","INSPECTION_BEGIN_DT":"12/18/2018","INSPECTION_END_DT":"12/18/2018","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2018-12-18"},{"SOURCE_ROW_NUMBER":"276469","EVENT_NO":"4456904","INSPECTION_BEGIN_DT":"12/18/2018","INSPECTION_END_DT":"01/02/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2018-12-18"},{"SOURCE_ROW_NUMBER":"46044","EVENT_NO":"4456859","INSPECTION_BEGIN_DT":"07/02/2018","INSPECTION_END_DT":"08/14/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.25","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2018-07-02"},{"SOURCE_ROW_NUMBER":"98655","EVENT_NO":"4454280","INSPECTION_BEGIN_DT":"05/30/2018","INSPECTION_END_DT":"05/30/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2018-05-30"},{"SOURCE_ROW_NUMBER":"990361","EVENT_NO":"4456851","INSPECTION_BEGIN_DT":"05/09/2018","INSPECTION_END_DT":"05/21/2018","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2018-05-09"},{"SOURCE_ROW_NUMBER":"801759","EVENT_NO":"4454550","INSPECTION_BEGIN_DT":"04/02/2018","INSPECTION_END_DT":"05/23/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18.25","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2018-04-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":47,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q4":{"hours":10,"employees":1,"production":0},"2017-Q1":{"hours":15300,"employees":26,"production":18511},"2016-Q4":{"hours":9402,"employees":21,"production":7843},"2016-Q3":{"hours":11275,"employees":23,"production":9942},"2016-Q2":{"hours":11135,"employees":24,"production":11290},"2016-Q1":{"hours":10250,"employees":22,"production":12404},"2015-Q4":{"hours":12478,"employees":28,"production":19965},"2015-Q3":{"hours":9295,"employees":23,"production":14939},"2015-Q2":{"hours":7550,"employees":18,"production":12030},"2015-Q1":{"hours":7926,"employees":18,"production":12365},"2014-Q4":{"hours":9911,"employees":21,"production":14530},"2014-Q3":{"hours":24038,"employees":20,"production":14569}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":20785,"employees":30,"production":41926},"2012":{"hours":23170,"employees":16,"production":26891},"2013":{"hours":33300,"employees":22,"production":43371},"2014":{"hours":43082,"employees":18,"production":46193},"2015":{"hours":37249,"employees":22,"production":59299},"2016":{"hours":42062,"employees":23,"production":41479},"2017":{"hours":15310,"employees":16,"production":18511}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":125,"firstDate":"2012-08-14","lastDate":"2017-08-15","metrics":{"recentRows":0,"doseOver100":14,"actDoseTotal":6624,"pelDoseTotal":4827},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"183251","EVENT_NO":"6431565","SURVEY_DATE":"08/15/2017","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"43","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"183250","EVENT_NO":"6431565","SURVEY_DATE":"08/15/2017","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"44","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"183249","EVENT_NO":"6431565","SURVEY_DATE":"08/15/2017","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"43","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"183248","EVENT_NO":"6431565","SURVEY_DATE":"08/15/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"59","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"183247","EVENT_NO":"6431565","SURVEY_DATE":"08/15/2017","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"120","PEL_DOSE_90":"107","SURVEY_TYPE":"I","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"183246","EVENT_NO":"6431565","SURVEY_DATE":"07/12/2017","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"50","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2017-07-12"},{"SOURCE_ROW_NUMBER":"183245","EVENT_NO":"6431558","SURVEY_DATE":"04/11/2017","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"24","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"183244","EVENT_NO":"6431558","SURVEY_DATE":"04/11/2017","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"49","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"183243","EVENT_NO":"6431558","SURVEY_DATE":"04/11/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"57","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"183242","EVENT_NO":"6431558","SURVEY_DATE":"04/11/2017","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"116","PEL_DOSE_90":"104","SURVEY_TYPE":"I","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"183241","EVENT_NO":"6431558","SURVEY_DATE":"04/11/2017","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"21","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"183240","EVENT_NO":"6431558","SURVEY_DATE":"04/06/2017","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"16","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2017-04-06"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":32,"firstDate":"2012-08-14","lastDate":"2017-08-15","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":13.4,"validSamples":29,"quartzPctTotal":159},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"155568","CASSETTE_NO":"58311639","SAMPLE_DT":"08/15/2017","QUARTZ_PCT":"09.1","QUARTZ_MICROGRAMS":"27","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"122865","CASSETTE_NO":"58311546","SAMPLE_DT":"08/15/2017","QUARTZ_PCT":"04.5","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"113259","CASSETTE_NO":"58311643","SAMPLE_DT":"08/15/2017","QUARTZ_PCT":"08.8","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"69927","CASSETTE_NO":"58284616","SAMPLE_DT":"07/12/2017","QUARTZ_PCT":"01.0","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-07-12"},{"SOURCE_ROW_NUMBER":"35909","CASSETTE_NO":"58284531","SAMPLE_DT":"04/11/2017","QUARTZ_PCT":"07.0","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"33998","CASSETTE_NO":"58284595","SAMPLE_DT":"04/11/2017","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"14033","CASSETTE_NO":"58284558","SAMPLE_DT":"04/11/2017","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-04-11"},{"SOURCE_ROW_NUMBER":"34454","CASSETTE_NO":"58284532","SAMPLE_DT":"04/06/2017","QUARTZ_PCT":"00.3","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-04-06"},{"SOURCE_ROW_NUMBER":"21891","CASSETTE_NO":"58267479","SAMPLE_DT":"02/10/2017","QUARTZ_PCT":"06.2","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-02-10"},{"SOURCE_ROW_NUMBER":"5266","CASSETTE_NO":"58267466","SAMPLE_DT":"02/10/2017","QUARTZ_PCT":"04.8","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2017-02-10"},{"SOURCE_ROW_NUMBER":"163801","CASSETTE_NO":"58267476","SAMPLE_DT":"02/08/2017","QUARTZ_PCT":"01.1","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-02-08"},{"SOURCE_ROW_NUMBER":"114549","CASSETTE_NO":"58267382","SAMPLE_DT":"11/22/2016","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"25","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-11-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":708,"firstDate":"2006-05-09","lastDate":"2018-12-21","metrics":{"ss":160,"amountDue":211892,"contested":0,"amountPaid":92125.43,"recentRows":0,"section104d":4,"unterminated":11,"proposedPenalty":211892},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2082517","VIOLATION_NO":"8314252","VIOLATION_ISSUE_DT":"12/21/2018","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"11/07/2023","CONTESTED_IND":"N","sourceDate":"2018-12-21"},{"SOURCE_ROW_NUMBER":"2082518","VIOLATION_NO":"9133090","VIOLATION_ISSUE_DT":"12/18/2018","SIG_SUB":"Y","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"4227","AMOUNT_DUE":"4227","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2018-12-18"},{"SOURCE_ROW_NUMBER":"2082008","VIOLATION_NO":"9133024","VIOLATION_ISSUE_DT":"05/21/2018","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2018","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2018-05-21"},{"SOURCE_ROW_NUMBER":"2082140","VIOLATION_NO":"9133021","VIOLATION_ISSUE_DT":"05/09/2018","SIG_SUB":"N","PART_SECTION":"50.20(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/21/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2018-05-09"},{"SOURCE_ROW_NUMBER":"2081843","VIOLATION_NO":"8372568","VIOLATION_ISSUE_DT":"01/23/2018","SIG_SUB":"N","PART_SECTION":"75.311(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2018-01-23"},{"SOURCE_ROW_NUMBER":"2082445","VIOLATION_NO":"8372564","VIOLATION_ISSUE_DT":"12/05/2017","SIG_SUB":"N","PART_SECTION":"75.512-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2017","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-12-05"},{"SOURCE_ROW_NUMBER":"2082444","VIOLATION_NO":"8372563","VIOLATION_ISSUE_DT":"11/21/2017","SIG_SUB":"N","PART_SECTION":"75.1100-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/21/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-11-21"},{"SOURCE_ROW_NUMBER":"2082455","VIOLATION_NO":"8842083","VIOLATION_ISSUE_DT":"11/20/2017","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"07/19/2018","CONTESTED_IND":"N","sourceDate":"2017-11-20"},{"SOURCE_ROW_NUMBER":"2082443","VIOLATION_NO":"8372562","VIOLATION_ISSUE_DT":"11/16/2017","SIG_SUB":"Y","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/16/2017","PROPOSED_PENALTY":"577","AMOUNT_DUE":"577","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-11-16"},{"SOURCE_ROW_NUMBER":"2082442","VIOLATION_NO":"8372561","VIOLATION_ISSUE_DT":"11/16/2017","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/16/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-11-16"},{"SOURCE_ROW_NUMBER":"2082441","VIOLATION_NO":"8372560","VIOLATION_ISSUE_DT":"11/16/2017","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/21/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-11-16"},{"SOURCE_ROW_NUMBER":"2082454","VIOLATION_NO":"8842079","VIOLATION_ISSUE_DT":"10/30/2017","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"467","AMOUNT_DUE":"467","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-10-30"}]}],"safety":{"href":"/api/v1/mines/4003273/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4003273/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Main mine fan operation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.311","part":"75","subchapter":"O","subpart":"D","id":"75.311","citation":"30 CFR 75.311","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512-2","heading":"Frequency of examinations.","id":"75.512-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"The examinations and tests required by § 75.512 shall be made at least weekly. Permissible equipment shall be examined to see that it is in permissible condition.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-1","heading":"Type and quality of firefighting equipment.","id":"75.1100-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment required under this subpart shall meet the following minimum requirements:\n\n(a) Waterlines: Waterlines shall be capable of delivering 50 gallons of water a minute at a nozzle pressure of 50 pounds per square inch.\n\n(b) Portable water cars: A portable water car shall be of at least 1,000 gallons capacity (500 gallons capacity for anthracite mines) and shall have at least 300 feet of fire hose with nozzles. A portable water car shall be capable of providing a flow through the hose of 50 gallons of water per minute at a nozzle pressure of 50 pounds per square inch.\n\n(c) A portable chemical car shall carry enough chemicals to provide a fire extinguishing capacity equivalent to that of a portable water car.\n\n(d) Portable foam-generating machines or devices: A portable foam-generating machine or device shall have facilities and equipment for supplying the machine with 30 gallons of water per minute at 30 pounds per square inch for a period of 35 minutes.\n\n(e) Portable fire extinguisher: A portable fire extinguisher shall be either (1) a multipurpose dry chemical type containing a nominal weight of 5 pounds of dry powder and enough expellant to apply the powder or (2) a foam-producing type containing at least 2 1/2 gallons of foam-producing liquids and enough expellant to supply the foam. Only fire extinguishers approved by the Underwriters Laboratories, Inc., or Factory Mutual Research Corp., carrying appropriate labels as to type and purpose, shall be used. After March 30, 1971, all new portable fire extinguishers acquired for use in a coal mine shall have a 2A 10 BC or higher rating.\n\n(f)(1) Except as provided in paragraph (f)(2) of this section, the fire hose shall be lined with a material having flame resistant qualities meeting requirements for hose in Bureau of Mines' Schedule 2G. The cover shall be polyester, or other material with flame-spread qualities and mildew resistance equal or superior to polyester. The bursting pressure shall be at least 4 times the water pressure at the valve to the hose inlet with the valve closed; the maximum water pressure in the hose nozzle shall not exceed 100 p.s.i.g.\n\n(2) Fire hose installed for use in underground coal mines prior to December 30, 1970, shall be mildew-proof and have a bursting pressure at least 4 times the water pressure at the valve to the hose inlet with the valve closed, and the maximum water pressure in the hose nozzle with water flowing shall not exceed 100 p.s.i.g.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4003273","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}