{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"4003175","name":"White Oak Mine","status":"Abandoned and Sealed","status_date":"2002-07-09","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"TN","county":"Campbell","nearest_town":"White Oak","operator_id":"P23841","operator_name":"Tennco Inc","controller_id":"C15892","controller_name":"Jackie (Mitch)  Fannin; Jack  Stump","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.500833,"longitude":-83.993056},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":248},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"4003175","name":"White Oak Mine"},"operator":{"type":"operator","id":"P23841","name":"Tennco Inc"},"controller":{"type":"controller","id":"C15892","name":"Jackie (Mitch)  Fannin; Jack  Stump"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15892","name":"Jackie (Mitch)  Fannin Et Al"},"object":{"type":"mine","id":"4003175","name":"White Oak Mine"},"validFrom":"1998-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003175|C15892|1998-02-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23841","name":"Tennco Inc"},"object":{"type":"mine","id":"4003175","name":"White Oak Mine"},"validFrom":"2001-07-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003175|P23841|2001-07-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15892","name":"Jackie (Mitch)  Fannin Et Al"},"object":{"type":"operator","id":"P23841","name":"Tennco Inc"},"validFrom":"2001-07-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4003175","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003175|P23841|2001-07-01|C15892|1998-02-01|97470"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15892","name":"Jack  Stump Et Al"},"object":{"type":"operator","id":"P23841","name":"Tennco Inc"},"validFrom":"2001-07-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"4003175","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"4003175|P23841|2001-07-01|C15892|1998-02-01|97471"}}],"coverage":{"historyRecords":2,"edgeCount":4,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":7,"firstDate":"2001-11-12","lastDate":"2002-05-27","metrics":{"daysLost":91,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"162083","DOCUMENT_NO":"220022350063","ACCIDENT_DT":"05/27/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"GETTING OFF OF FORKLIFT AND FOOT SLIPPED AND CAUGHT BRACKET WITH KNEE.","sourceDate":"2002-05-27"},{"SOURCE_ROW_NUMBER":"114639","DOCUMENT_NO":"220020910061","ACCIDENT_DT":"03/21/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL IN #5 ENTRY AT #12 BREAK. INTERSECTION.","sourceDate":"2002-03-21"},{"SOURCE_ROW_NUMBER":"71651","DOCUMENT_NO":"220020630010","ACCIDENT_DT":"02/21/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"91","NARRATIVE":"WAS BOLTING TOP WITH FLETCHER ROOF BOLTER & PIECE OF DRAW ROCK FELL & CAME BETWEEN ATRS & CANOPY AND STRUCK HIM IN THE LEFT LEG AND BROKE LEG.","sourceDate":"2002-02-21"},{"SOURCE_ROW_NUMBER":"20132","DOCUMENT_NO":"220020450010","ACCIDENT_DT":"02/06/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL IN #6 ENTRY AT #18 BREAK.","sourceDate":"2002-02-06"},{"SOURCE_ROW_NUMBER":"230933","DOCUMENT_NO":"220013600034","ACCIDENT_DT":"12/16/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL IN #5 ENTRY OF MAINLINE. ROOF FALL IS IN #4 BREAK AND IS APPROX. 16'X 40' AND 20'HIGH.","sourceDate":"2001-12-16"},{"SOURCE_ROW_NUMBER":"114638","DOCUMENT_NO":"220013600031","ACCIDENT_DT":"12/16/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROCKFALL WAS IN #4 ENTRY IN MAINS. 18'X 30' AND 20'HIGH. ROCKFALL WAS IN #7 BREAK ON MAINLINE.","sourceDate":"2001-12-16"},{"SOURCE_ROW_NUMBER":"162082","DOCUMENT_NO":"220020720047","ACCIDENT_DT":"11/12/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS BOLTING AND WRENCH POPPED OUT AND HIT LEFT FOREARM.","sourceDate":"2001-11-12"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-07-09","lastDate":"2002-07-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":51,"firstDate":"2001-08-09","lastDate":"2003-01-13","metrics":{"ss":18,"delinquent":51,"recentRows":0,"paidPenalty":4199,"proposedPenalty":4346,"currentAssessment":4199},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1158213","VIOLATION_NO":"7466809","ISSUE_DT":"01/13/2003","CFR_STANDARD_CD":"50.20(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-13"},{"SOURCE_ROW_NUMBER":"1126286","VIOLATION_NO":"7466783","ISSUE_DT":"05/20/2002","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-20"},{"SOURCE_ROW_NUMBER":"1126285","VIOLATION_NO":"7466782","ISSUE_DT":"05/20/2002","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-20"},{"SOURCE_ROW_NUMBER":"1126284","VIOLATION_NO":"7466781","ISSUE_DT":"04/30/2002","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-30"},{"SOURCE_ROW_NUMBER":"1126283","VIOLATION_NO":"7466780","ISSUE_DT":"04/30/2002","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-30"},{"SOURCE_ROW_NUMBER":"1126282","VIOLATION_NO":"7466779","ISSUE_DT":"04/30/2002","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"242.00","CURRENT_ASSESSMENT_AMT":"242.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-30"},{"SOURCE_ROW_NUMBER":"1126281","VIOLATION_NO":"7466778","ISSUE_DT":"04/29/2002","CFR_STANDARD_CD":"75.220(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-29"},{"SOURCE_ROW_NUMBER":"1126280","VIOLATION_NO":"7466777","ISSUE_DT":"03/27/2002","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"122.00","CURRENT_ASSESSMENT_AMT":"122.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-27"},{"SOURCE_ROW_NUMBER":"1131530","VIOLATION_NO":"7451847","ISSUE_DT":"03/26/2002","CFR_STANDARD_CD":"75.1914(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"1131529","VIOLATION_NO":"7451846","ISSUE_DT":"03/26/2002","CFR_STANDARD_CD":"72.510(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"1126279","VIOLATION_NO":"7466776","ISSUE_DT":"03/21/2002","CFR_STANDARD_CD":"75.364(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-21"},{"SOURCE_ROW_NUMBER":"1093067","VIOLATION_NO":"7509937","ISSUE_DT":"03/15/2002","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"122.00","CURRENT_ASSESSMENT_AMT":"122.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":80,"firstDate":"2001-09-11","lastDate":"2002-05-17","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":72,"maxConcentration":3.436,"concentrationTotal":31.792},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1212660","CASS_NUM":"50659592","SMP_TAKEN_DT":"5/17/2002","CONC":".957","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-17"},{"SOURCE_ROW_NUMBER":"426463","CASS_NUM":"50624654","SMP_TAKEN_DT":"5/16/2002","CONC":".681","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-16"},{"SOURCE_ROW_NUMBER":"1539721","CASS_NUM":"57414415","SMP_TAKEN_DT":"5/15/2002","CONC":"0","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"1480245","CASS_NUM":"50624599","SMP_TAKEN_DT":"5/15/2002","CONC":".606","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"1160697","CASS_NUM":"57414468","SMP_TAKEN_DT":"5/15/2002","CONC":".14","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"1131111","CASS_NUM":"57414421","SMP_TAKEN_DT":"5/15/2002","CONC":".228","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"Invalid Code","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"1112456","CASS_NUM":"57414463","SMP_TAKEN_DT":"5/15/2002","CONC":".125","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"1004051","CASS_NUM":"57414412","SMP_TAKEN_DT":"5/15/2002","CONC":".242","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"490834","CASS_NUM":"57414435","SMP_TAKEN_DT":"5/15/2002","CONC":".193","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"490106","CASS_NUM":"57414448","SMP_TAKEN_DT":"5/15/2002","CONC":".23","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"465937","CASS_NUM":"57414447","SMP_TAKEN_DT":"5/15/2002","CONC":".388","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-15"},{"SOURCE_ROW_NUMBER":"671812","CASS_NUM":"50624602","SMP_TAKEN_DT":"5/14/2002","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-05-14"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2001-10-05","lastDate":"2001-10-05","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2001-07-01","lastDate":"2001-07-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":29,"firstDate":"2001-08-09","lastDate":"2003-01-13","metrics":{"inspectors":36,"recentRows":0,"onSiteHours":487.5,"inspectionHours":746,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"548045","EVENT_NO":"4241507","INSPECTION_BEGIN_DT":"01/13/2003","INSPECTION_END_DT":"01/13/2003","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2003-01-13"},{"SOURCE_ROW_NUMBER":"432037","EVENT_NO":"4225083","INSPECTION_BEGIN_DT":"06/26/2002","INSPECTION_END_DT":"07/08/2002","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2002-06-26"},{"SOURCE_ROW_NUMBER":"835470","EVENT_NO":"4228948","INSPECTION_BEGIN_DT":"05/13/2002","INSPECTION_END_DT":"05/15/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2002-05-13"},{"SOURCE_ROW_NUMBER":"814987","EVENT_NO":"4228586","INSPECTION_BEGIN_DT":"04/24/2002","INSPECTION_END_DT":"06/20/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"97.5","SUM_TOTAL_ON_SITE_HOURS":"73.5","sourceDate":"2002-04-24"},{"SOURCE_ROW_NUMBER":"647852","EVENT_NO":"4230891","INSPECTION_BEGIN_DT":"03/26/2002","INSPECTION_END_DT":"03/27/2002","ACTIVITY_CODE":"AEA","ACTIVITY":"TOXIC SUBS OR HARMFUL PHY AGENT INV","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"611541","EVENT_NO":"4228582","INSPECTION_BEGIN_DT":"03/21/2002","INSPECTION_END_DT":"03/21/2002","ACTIVITY_CODE":"AFC","ACTIVITY":"NON-INJURY ACCIDENT INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2002-03-21"},{"SOURCE_ROW_NUMBER":"878986","EVENT_NO":"4213982","INSPECTION_BEGIN_DT":"03/15/2002","INSPECTION_END_DT":"03/15/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2002-03-15"},{"SOURCE_ROW_NUMBER":"681868","EVENT_NO":"4228737","INSPECTION_BEGIN_DT":"03/12/2002","INSPECTION_END_DT":"03/28/2002","ACTIVITY_CODE":"CBA","ACTIVITY":"ELECTRICAL INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"78.5","SUM_TOTAL_ON_SITE_HOURS":"54.5","sourceDate":"2002-03-12"},{"SOURCE_ROW_NUMBER":"507529","EVENT_NO":"4228576","INSPECTION_BEGIN_DT":"03/05/2002","INSPECTION_END_DT":"03/28/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"55","SUM_TOTAL_ON_SITE_HOURS":"42","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"263889","EVENT_NO":"4221504","INSPECTION_BEGIN_DT":"03/05/2002","INSPECTION_END_DT":"03/05/2002","ACTIVITY_CODE":"CEA","ACTIVITY":"ROOF CONTROL TECHNICAL INVESTIGTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"890892","EVENT_NO":"4228932","INSPECTION_BEGIN_DT":"02/27/2002","INSPECTION_END_DT":"03/01/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2002-02-27"},{"SOURCE_ROW_NUMBER":"4339","EVENT_NO":"4211446","INSPECTION_BEGIN_DT":"02/21/2002","INSPECTION_END_DT":"05/15/2002","ACTIVITY_CODE":"AFB","ACTIVITY":"NONFATAL INJURY ACCIDENT INV","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2002-02-21"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q3":{"hours":0,"employees":0,"production":0},"2002-Q2":{"hours":15016,"employees":28,"production":44206},"2002-Q1":{"hours":20828,"employees":37,"production":124646},"2001-Q4":{"hours":19647,"employees":35,"production":110873},"2001-Q3":{"hours":5826,"employees":21,"production":44045}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":25473,"employees":28,"production":154918},"2002":{"hours":35844,"employees":33,"production":168852}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":9,"firstDate":"2001-10-02","lastDate":"2001-12-27","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":594,"pelDoseTotal":479},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"181928","EVENT_NO":"4228918","SURVEY_DATE":"12/27/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"033","ACT_DOSE_85":"17","PEL_DOSE_90":"13","SURVEY_TYPE":"F","sourceDate":"2001-12-27"},{"SOURCE_ROW_NUMBER":"181927","EVENT_NO":"4228918","SURVEY_DATE":"12/27/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"033","ACT_DOSE_85":"6","PEL_DOSE_90":"4","SURVEY_TYPE":"F","sourceDate":"2001-12-27"},{"SOURCE_ROW_NUMBER":"181926","EVENT_NO":"4228918","SURVEY_DATE":"12/27/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"15","PEL_DOSE_90":"13","SURVEY_TYPE":"F","sourceDate":"2001-12-27"},{"SOURCE_ROW_NUMBER":"181925","EVENT_NO":"4228918","SURVEY_DATE":"12/27/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"10","PEL_DOSE_90":"8","SURVEY_TYPE":"F","sourceDate":"2001-12-27"},{"SOURCE_ROW_NUMBER":"181924","EVENT_NO":"4228902","SURVEY_DATE":"10/02/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"176","PEL_DOSE_90":"164","SURVEY_TYPE":"I","sourceDate":"2001-10-02"},{"SOURCE_ROW_NUMBER":"181923","EVENT_NO":"4228902","SURVEY_DATE":"10/02/2001","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"73","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2001-10-02"},{"SOURCE_ROW_NUMBER":"181922","EVENT_NO":"4228902","SURVEY_DATE":"10/02/2001","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"68","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2001-10-02"},{"SOURCE_ROW_NUMBER":"181921","EVENT_NO":"4228902","SURVEY_DATE":"10/02/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"85","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2001-10-02"},{"SOURCE_ROW_NUMBER":"181920","EVENT_NO":"4228902","SURVEY_DATE":"10/02/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"144","PEL_DOSE_90":"136","SURVEY_TYPE":"I","sourceDate":"2001-10-02"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":1,"firstDate":"2001-11-08","lastDate":"2001-11-08","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":3.9,"validSamples":1,"quartzPctTotal":3.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"108489","CASSETTE_NO":"57358405","SAMPLE_DT":"11/08/2001","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":52,"firstDate":"2001-08-09","lastDate":"2003-01-13","metrics":{"ss":18,"amountDue":4199,"contested":0,"amountPaid":4199,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":4346},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2076552","VIOLATION_NO":"7466809","VIOLATION_ISSUE_DT":"01/13/2003","SIG_SUB":"N","PART_SECTION":"50.20(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/13/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-01-13"},{"SOURCE_ROW_NUMBER":"2076571","VIOLATION_NO":"7466783","VIOLATION_ISSUE_DT":"05/20/2002","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/22/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-05-20"},{"SOURCE_ROW_NUMBER":"2076570","VIOLATION_NO":"7466782","VIOLATION_ISSUE_DT":"05/20/2002","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/22/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-05-20"},{"SOURCE_ROW_NUMBER":"2076569","VIOLATION_NO":"7466781","VIOLATION_ISSUE_DT":"04/30/2002","SIG_SUB":"Y","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/01/2002","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2002-04-30"},{"SOURCE_ROW_NUMBER":"2076568","VIOLATION_NO":"7466780","VIOLATION_ISSUE_DT":"04/30/2002","SIG_SUB":"Y","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/01/2002","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2002-04-30"},{"SOURCE_ROW_NUMBER":"2076567","VIOLATION_NO":"7466779","VIOLATION_ISSUE_DT":"04/30/2002","SIG_SUB":"Y","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/01/2002","PROPOSED_PENALTY":"242","AMOUNT_DUE":"242","AMOUNT_PAID":"242","CONTESTED_IND":"N","sourceDate":"2002-04-30"},{"SOURCE_ROW_NUMBER":"2076566","VIOLATION_NO":"7466778","VIOLATION_ISSUE_DT":"04/29/2002","SIG_SUB":"N","PART_SECTION":"75.220(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/29/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-04-29"},{"SOURCE_ROW_NUMBER":"2076557","VIOLATION_NO":"7466777","VIOLATION_ISSUE_DT":"03/27/2002","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/27/2002","PROPOSED_PENALTY":"122","AMOUNT_DUE":"122","AMOUNT_PAID":"122","CONTESTED_IND":"N","sourceDate":"2002-03-27"},{"SOURCE_ROW_NUMBER":"2076565","VIOLATION_NO":"7451847","VIOLATION_ISSUE_DT":"03/26/2002","SIG_SUB":"N","PART_SECTION":"75.1914(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"2076564","VIOLATION_NO":"7451846","VIOLATION_ISSUE_DT":"03/26/2002","SIG_SUB":"N","PART_SECTION":"72.510(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"20","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"2076556","VIOLATION_NO":"7466776","VIOLATION_ISSUE_DT":"03/21/2002","SIG_SUB":"N","PART_SECTION":"75.364(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-03-21"},{"SOURCE_ROW_NUMBER":"2076563","VIOLATION_NO":"7509937","VIOLATION_ISSUE_DT":"03/15/2002","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/20/2002","PROPOSED_PENALTY":"122","AMOUNT_DUE":"122","AMOUNT_PAID":"122","CONTESTED_IND":"N","sourceDate":"2002-03-15"}]}],"safety":{"href":"/api/v1/mines/4003175/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/4003175/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Preparation and submission of MSHA Report Form 7000-1—Mine Accident, Injury, and Illness Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20","part":"50","subchapter":"I","subpart":"C","id":"50.20","citation":"30 CFR 50.20","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1914","heading":"Maintenance of diesel-powered equipment.","id":"75.1914","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1914","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Diesel-powered equipment shall be maintained in approved and safe condition or removed from service.\n\n(b) Maintenance and repairs of approved features and those features required by §§ 75.1909 and 75.1910 on diesel-powered equipment shall be made only by a person qualified under § 75.1915.\n\n(c) The water scrubber system on diesel-powered equipment shall be drained and flushed, by a person who is trained to perform this task, at least once on each shift in which the equipment is operated.\n\n(d) The intake air filter on diesel-powered equipment shall be replaced or serviced, by a person who is trained to perform this task, when the intake air pressure drop device so indicates or when the engine manufacturer's maximum allowable air pressure drop level is exceeded.\n\n(e) Mobile diesel-powered equipment that is to be used during a shift shall be visually examined by the equipment operator before being placed in operation. Equipment defects affecting safety shall be reported promptly to the mine operator.\n\n(f) All diesel-powered equipment shall be examined and tested weekly by a person qualified under § 75.1915.\n\n(1) Examinations and tests shall be conducted in accordance with approved checklists and manufacturers' maintenance manuals.\n\n(2) Persons performing weekly examinations and tests of diesel-powered equipment under this paragraph shall make a record when the equipment is not in approved or safe condition. The record shall include the equipment that is not in approved or safe condition, the defect found, and the corrective action taken.\n\n(g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:\n\n(1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;\n\n(2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;\n\n(3) The method of evaluation and interpretation of the results;\n\n(4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and\n\n(5) The maintenance of records necessary to track engine performance.\n\n(h) Recordkeeping. Records required by paragraphs (f)(2) and (g)(5) shall be—\n\n(1) Recorded in a secure book that is not susceptible to alteration, or recorded electronically in a computer system that is secure and not susceptible to alteration; and\n\n(2) Retained at a surface location at the mine for at least 1 year and made available for inspection by an authorized representative of the Secretary and by miners' representatives.\n\n(i) Diesel-powered equipment must be maintained in accordance with this part as of November 25, 1997.","occurrenceCount":1},{"chapter":"I","heading":"Miner health training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-D/section-72.510","part":"72","subchapter":"O","subpart":"D","id":"72.510","citation":"30 CFR 72.510","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"4003175","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}