{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"3610330","name":"Rausch Creek Gen Good Spring Bank","status":"Active","status_date":"2023-05-11","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Anthracite)","state":"PA","county":"Schuylkill","nearest_town":"Valley View","operator_id":"0165193","operator_name":"Rausch Creek Fuel, LLC","controller_id":"0145403","controller_name":"Robert  Rivkin","district":"M2","office":"Frackville PA Field Office","employees":4,"latitude":40.622222,"longitude":-76.499722},"coverage":{"contributingSources":9,"registeredSources":20,"sourceRows":81},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3610330","name":"Rausch Creek Gen Good Spring Bank"},"operator":{"type":"operator","id":"0165193","name":"Rausch Creek Fuel, LLC"},"controller":{"type":"controller","id":"0145403","name":"Robert  Rivkin"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0145403","name":"Robert  Rivkin"},"object":{"type":"mine","id":"3610330","name":"Rausch Creek Gen Good Spring Bank"},"validFrom":"2019-05-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3610330|0145403|2019-05-30|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0165193","name":"Rausch Creek Fuel, LLC"},"object":{"type":"mine","id":"3610330","name":"Rausch Creek Gen Good Spring Bank"},"validFrom":"2020-05-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3610330|0165193|2020-05-28|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0145403","name":"Robert  Rivkin"},"object":{"type":"operator","id":"0165193","name":"Rausch Creek Fuel, LLC"},"validFrom":"2020-05-28","validTo":null,"current":true,"derived":true,"evidenceMineId":"3610330","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3610330|0165193|2020-05-28|0145403|2019-05-30|29776"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2023-05-11","lastDate":"2023-05-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":9,"firstDate":"2023-08-21","lastDate":"2026-08-06","metrics":{"ss":1,"delinquent":9,"recentRows":9,"paidPenalty":1033,"proposedPenalty":1335,"currentAssessment":1335},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3007591","VIOLATION_NO":"5155648","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"71.403(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"3007590","VIOLATION_NO":"5155647","ISSUE_DT":"08/05/2026","CFR_STANDARD_CD":"77.1600(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2981605","VIOLATION_NO":"9604087","ISSUE_DT":"04/01/2025","CFR_STANDARD_CD":"71.600","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-04-01"},{"SOURCE_ROW_NUMBER":"2981604","VIOLATION_NO":"9604086","ISSUE_DT":"04/01/2025","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-04-01"},{"SOURCE_ROW_NUMBER":"2915556","VIOLATION_NO":"9209893","ISSUE_DT":"11/06/2024","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-11-06"},{"SOURCE_ROW_NUMBER":"2915555","VIOLATION_NO":"9209892","ISSUE_DT":"11/04/2024","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-11-04"},{"SOURCE_ROW_NUMBER":"1316691","VIOLATION_NO":"9209477","ISSUE_DT":"05/13/2024","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-05-13"},{"SOURCE_ROW_NUMBER":"1316333","VIOLATION_NO":"9209226","ISSUE_DT":"11/15/2023","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-11-15"},{"SOURCE_ROW_NUMBER":"1316026","VIOLATION_NO":"8005070","ISSUE_DT":"08/21/2023","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-08-21"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":35,"firstDate":"2020-11-30","lastDate":"2026-09-14","metrics":{"recentRows":34,"cpdmSamples":0,"voidSamples":2,"validSamples":33,"maxConcentration":0.553,"concentrationTotal":2.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1372326","CASS_NUM":"51674681","SMP_TAKEN_DT":"9/14/2026","CONC":".017","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"464468","CASS_NUM":"51674687","SMP_TAKEN_DT":"9/14/2026","CONC":".011","SMP_TYPE_CD_DESC":"INVALID SAMPLE TYPE","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-09-14"},{"SOURCE_ROW_NUMBER":"1465754","CASS_NUM":"58588840","SMP_TAKEN_DT":"8/6/2026","CONC":".029","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"1560084","CASS_NUM":"58588745","SMP_TAKEN_DT":"8/5/2026","CONC":".191","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"1418643","CASS_NUM":"58588501","SMP_TAKEN_DT":"8/5/2026","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"672538","CASS_NUM":"58588746","SMP_TAKEN_DT":"8/5/2026","CONC":".185","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"257116","CASS_NUM":"58588498","SMP_TAKEN_DT":"8/5/2026","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"988620","CASS_NUM":"51665206","SMP_TAKEN_DT":"10/27/2025","CONC":".009","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-10-27"},{"SOURCE_ROW_NUMBER":"1141478","CASS_NUM":"58560725","SMP_TAKEN_DT":"10/8/2025","CONC":".02","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"942195","CASS_NUM":"58560676","SMP_TAKEN_DT":"10/8/2025","CONC":".029","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"1231498","CASS_NUM":"51665197","SMP_TAKEN_DT":"9/22/2025","CONC":".022","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-09-22"},{"SOURCE_ROW_NUMBER":"1014438","CASS_NUM":"51650384","SMP_TAKEN_DT":"6/26/2025","CONC":".061","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-06-26"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2020-05-28","lastDate":"2020-05-28","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":9,"firstDate":"2020-06-15","lastDate":"2026-08-24","metrics":{"inspectors":10,"recentRows":8,"onSiteHours":149,"inspectionHours":204,"inspectionSamples":16},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"952143","EVENT_NO":"F026224","INSPECTION_BEGIN_DT":"08/24/2026","INSPECTION_END_DT":"08/24/2026","ACTIVITY_CODE":"E15","ACTIVITY":"Compliance Follow-up Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"942282","EVENT_NO":"F026221","INSPECTION_BEGIN_DT":"08/04/2026","INSPECTION_END_DT":"08/06/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"38.5","SUM_TOTAL_ON_SITE_HOURS":"33","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"246123","EVENT_NO":"F0183E8","INSPECTION_BEGIN_DT":"10/01/2025","INSPECTION_END_DT":"10/08/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"28","SUM_TOTAL_ON_SITE_HOURS":"20","sourceDate":"2025-10-01"},{"SOURCE_ROW_NUMBER":"721771","EVENT_NO":"F017541","INSPECTION_BEGIN_DT":"04/01/2025","INSPECTION_END_DT":"05/05/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.75","SUM_TOTAL_ON_SITE_HOURS":"19.25","sourceDate":"2025-04-01"},{"SOURCE_ROW_NUMBER":"279079","EVENT_NO":"F0055DB","INSPECTION_BEGIN_DT":"10/30/2024","INSPECTION_END_DT":"11/20/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25.5","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2024-10-30"},{"SOURCE_ROW_NUMBER":"857813","EVENT_NO":"4315130","INSPECTION_BEGIN_DT":"05/13/2024","INSPECTION_END_DT":"05/23/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.5","SUM_TOTAL_ON_SITE_HOURS":"18.25","sourceDate":"2024-05-13"},{"SOURCE_ROW_NUMBER":"555257","EVENT_NO":"4314843","INSPECTION_BEGIN_DT":"11/15/2023","INSPECTION_END_DT":"12/06/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"21.75","SUM_TOTAL_ON_SITE_HOURS":"15.75","sourceDate":"2023-11-15"},{"SOURCE_ROW_NUMBER":"1015356","EVENT_NO":"4314477","INSPECTION_BEGIN_DT":"08/16/2023","INSPECTION_END_DT":"08/30/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"41","SUM_TOTAL_ON_SITE_HOURS":"28.75","sourceDate":"2023-08-16"},{"SOURCE_ROW_NUMBER":"1049644","EVENT_NO":"4313301","INSPECTION_BEGIN_DT":"06/15/2020","INSPECTION_END_DT":"06/15/2020","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2020-06-15"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2020":{"hours":410,"employees":3,"production":0},"2021":{"hours":135,"employees":1,"production":0},"2023":{"hours":1058,"employees":2,"production":0},"2024":{"hours":2418,"employees":2,"production":0},"2025":{"hours":1934,"employees":3,"production":0},"2026":{"hours":900,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2023-08-21","lastDate":"2025-10-08","metrics":{"recentRows":10,"doseOver100":0,"actDoseTotal":294,"pelDoseTotal":138},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"180212","EVENT_NO":"F0183E8","SURVEY_DATE":"10/08/2025","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"28","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"180211","EVENT_NO":"F0183E8","SURVEY_DATE":"10/08/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"42","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2025-10-08"},{"SOURCE_ROW_NUMBER":"180210","EVENT_NO":"F0055DB","SURVEY_DATE":"11/06/2024","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2024-11-06"},{"SOURCE_ROW_NUMBER":"180209","EVENT_NO":"F0055DB","SURVEY_DATE":"11/06/2024","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"14","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2024-11-06"},{"SOURCE_ROW_NUMBER":"180208","EVENT_NO":"F0055DB","SURVEY_DATE":"11/06/2024","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"63","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2024-11-06"},{"SOURCE_ROW_NUMBER":"180207","EVENT_NO":"4315130","SURVEY_DATE":"05/14/2024","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2024-05-14"},{"SOURCE_ROW_NUMBER":"180206","EVENT_NO":"4315130","SURVEY_DATE":"05/14/2024","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2024-05-14"},{"SOURCE_ROW_NUMBER":"180205","EVENT_NO":"4315130","SURVEY_DATE":"05/14/2024","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"50","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2024-05-14"},{"SOURCE_ROW_NUMBER":"180204","EVENT_NO":"4314843","SURVEY_DATE":"11/27/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"40","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2023-11-27"},{"SOURCE_ROW_NUMBER":"180203","EVENT_NO":"4314477","SURVEY_DATE":"08/21/2023","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"47","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2023-08-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":9,"firstDate":"2023-08-21","lastDate":"2026-08-06","metrics":{"ss":1,"amountDue":1335,"contested":0,"amountPaid":1033,"recentRows":9,"section104d":0,"unterminated":0,"proposedPenalty":1335},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2009004","VIOLATION_NO":"5155648","VIOLATION_ISSUE_DT":"08/06/2026","SIG_SUB":"N","PART_SECTION":"71.403(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/24/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"2009003","VIOLATION_NO":"5155647","VIOLATION_ISSUE_DT":"08/05/2026","SIG_SUB":"N","PART_SECTION":"77.1600(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/05/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-05"},{"SOURCE_ROW_NUMBER":"2009001","VIOLATION_NO":"9604087","VIOLATION_ISSUE_DT":"04/01/2025","SIG_SUB":"N","PART_SECTION":"71.600","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/01/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-04-01"},{"SOURCE_ROW_NUMBER":"2009000","VIOLATION_NO":"9604086","VIOLATION_ISSUE_DT":"04/01/2025","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/01/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-04-01"},{"SOURCE_ROW_NUMBER":"2009007","VIOLATION_NO":"9209893","VIOLATION_ISSUE_DT":"11/06/2024","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/06/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-11-06"},{"SOURCE_ROW_NUMBER":"2009006","VIOLATION_NO":"9209892","VIOLATION_ISSUE_DT":"11/04/2024","SIG_SUB":"Y","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/04/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-11-04"},{"SOURCE_ROW_NUMBER":"2009002","VIOLATION_NO":"9209477","VIOLATION_ISSUE_DT":"05/13/2024","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/13/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-05-13"},{"SOURCE_ROW_NUMBER":"2009008","VIOLATION_NO":"9209226","VIOLATION_ISSUE_DT":"11/15/2023","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2023","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2023-11-15"},{"SOURCE_ROW_NUMBER":"2009005","VIOLATION_NO":"8005070","VIOLATION_ISSUE_DT":"08/21/2023","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/21/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-08-21"}]}],"safety":{"href":"/api/v1/mines/3610330/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3610330/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Waiver of surface facilities requirements; posting of waiver.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-E/section-71.403","part":"71","subchapter":"O","subpart":"E","id":"71.403","citation":"30 CFR 71.403","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Loading and haulage; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1600","part":"77","subchapter":"O","subpart":"Q","id":"77.1600","citation":"30 CFR 77.1600","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Drinking water; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-G/section-71.600","part":"71","subchapter":"O","subpart":"G","id":"71.600","citation":"30 CFR 71.600","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":5},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3610330","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}