{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3609963","name":"Slope #2","status":"Active","status_date":"2025-07-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Anthracite)","state":"PA","county":"Schuylkill","nearest_town":"Pottsville","operator_id":"0126994","operator_name":"S & J Coal Mine","controller_id":"0072271","controller_name":"Kerry  Harris","district":"M2","office":"Frackville PA Field Office","employees":3,"latitude":40.730556,"longitude":-76.251389},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1593},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609963","name":"Slope #2"},"operator":{"type":"operator","id":"0126994","name":"S & J Coal Mine"},"controller":{"type":"controller","id":"0072271","name":"Kerry  Harris"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0072271","name":"Kerry  Harris"},"object":{"type":"mine","id":"3609963","name":"Slope #2"},"validFrom":"2011-09-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609963|0072271|2011-09-30|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0119570","name":"D & F Deep Mine"},"object":{"type":"mine","id":"3609963","name":"Slope #2"},"validFrom":"2011-10-19","validTo":"2013-02-26","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609963|0119570|2011-10-19|2013-02-26"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0072271","name":"Kerry  Harris"},"object":{"type":"operator","id":"0119570","name":"D & F Deep Mine"},"validFrom":"2011-10-19","validTo":"2013-02-26","current":false,"derived":true,"evidenceMineId":"3609963","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609963|0119570|2011-10-19|0072271|2011-09-30|11181"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0126994","name":"S & J Coal Mine"},"object":{"type":"mine","id":"3609963","name":"Slope #2"},"validFrom":"2013-02-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609963|0126994|2013-02-27|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0072271","name":"Kerry  Harris"},"object":{"type":"mine","id":"3609963","name":"Slope #2"},"validFrom":"2013-02-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609963|0072271|2013-02-27|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0072271","name":"Kerry  Harris"},"object":{"type":"operator","id":"0126994","name":"S & J Coal Mine"},"validFrom":"2013-02-27","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609963","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609963|0126994|2013-02-27|0072271|2013-02-27|11182"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":2,"firstDate":"2014-03-03","lastDate":"2014-03-03","metrics":{"daysLost":191,"injuries":4,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"183514","DOCUMENT_NO":"220140730005","ACCIDENT_DT":"03/03/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"2","DAYS_LOST":"55","NARRATIVE":"Piece of loose slate on roof fell before timber was properly secure against top.","sourceDate":"2014-03-03"},{"SOURCE_ROW_NUMBER":"7148","DOCUMENT_NO":"220140730004","ACCIDENT_DT":"03/03/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"2","DAYS_LOST":"136","NARRATIVE":"Piece of loose slate on roof fell, before timber was properly secure against top.","sourceDate":"2014-03-03"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2025-07-01","lastDate":"2025-07-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":112,"firstDate":"2011-12-07","lastDate":"2026-08-03","metrics":{"ss":21,"delinquent":111,"recentRows":23,"paidPenalty":43978,"proposedPenalty":361721,"currentAssessment":163823},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3013715","VIOLATION_NO":"9606441","ISSUE_DT":"08/03/2026","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"3006884","VIOLATION_NO":"5155628","ISSUE_DT":"04/20/2026","CFR_STANDARD_CD":"77.206(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-04-20"},{"SOURCE_ROW_NUMBER":"3012144","VIOLATION_NO":"9606289","ISSUE_DT":"11/10/2025","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2025-11-10"},{"SOURCE_ROW_NUMBER":"2973169","VIOLATION_NO":"9606420","ISSUE_DT":"08/25/2025","CFR_STANDARD_CD":"70.212(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2025-08-25"},{"SOURCE_ROW_NUMBER":"2973168","VIOLATION_NO":"9606419","ISSUE_DT":"08/11/2025","CFR_STANDARD_CD":"75.1505(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2025-08-11"},{"SOURCE_ROW_NUMBER":"2973146","VIOLATION_NO":"9603941","ISSUE_DT":"04/23/2025","CFR_STANDARD_CD":"75.1312(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2025-04-23"},{"SOURCE_ROW_NUMBER":"2930316","VIOLATION_NO":"9603932","ISSUE_DT":"02/03/2025","CFR_STANDARD_CD":"77.1102","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2025-02-03"},{"SOURCE_ROW_NUMBER":"1316429","VIOLATION_NO":"8005806","ISSUE_DT":"01/23/2024","CFR_STANDARD_CD":"75.381(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2024-01-23"},{"SOURCE_ROW_NUMBER":"1316146","VIOLATION_NO":"8005803","ISSUE_DT":"10/10/2023","CFR_STANDARD_CD":"75.1730(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2023-10-10"},{"SOURCE_ROW_NUMBER":"1316141","VIOLATION_NO":"8005318","ISSUE_DT":"07/24/2023","CFR_STANDARD_CD":"75.333(c)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2023-07-24"},{"SOURCE_ROW_NUMBER":"1316137","VIOLATION_NO":"8005314","ISSUE_DT":"04/12/2023","CFR_STANDARD_CD":"75.1100-2(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2023-04-12"},{"SOURCE_ROW_NUMBER":"1315833","VIOLATION_NO":"8005778","ISSUE_DT":"01/11/2023","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2023-01-11"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":9,"firstDate":"2015-01-08","lastDate":"2015-01-08","metrics":{"appeals":0,"decisions":9,"recentRows":0,"decisionPenalty":147975,"originalPenalty":345873},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"343270","VIOLATION_NO":"8000172","DOCKET_NO":"PENN 2013-199","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"342486","VIOLATION_NO":"8000176","DOCKET_NO":"PENN 2013-199","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"342485","VIOLATION_NO":"8000169","DOCKET_NO":"PENN 2013-198","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"90700.00","DECISION_PENALTY_AMT":"70001.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"333952","VIOLATION_NO":"8000177","DOCKET_NO":"PENN 2013-26","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"705.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"333051","VIOLATION_NO":"8000175","DOCKET_NO":"PENN 2013-27","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"332841","VIOLATION_NO":"8000173","DOCKET_NO":"PENN 2013-27","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"332840","VIOLATION_NO":"8000167","DOCKET_NO":"PENN 2013-26","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":"1073.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"97094","VIOLATION_NO":"8000174","DOCKET_NO":"PENN 2013-198","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"90700.00","DECISION_PENALTY_AMT":"70001.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"},{"SOURCE_ROW_NUMBER":"96995","VIOLATION_NO":"8000171","DOCKET_NO":"PENN 2013-199","DECISION_DT":"01/08/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-01-08"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":951,"firstDate":"2011-12-14","lastDate":"2026-08-28","metrics":{"recentRows":337,"cpdmSamples":0,"voidSamples":58,"validSamples":893,"maxConcentration":1.356,"concentrationTotal":65.553},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"546009","CASS_NUM":"51674244","SMP_TAKEN_DT":"8/28/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID INITIAL WEIGHT","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-28"},{"SOURCE_ROW_NUMBER":"464273","CASS_NUM":"51671616","SMP_TAKEN_DT":"8/27/2026","CONC":".041","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"243872","CASS_NUM":"51671608","SMP_TAKEN_DT":"8/26/2026","CONC":".024","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"1082814","CASS_NUM":"51671614","SMP_TAKEN_DT":"8/25/2026","CONC":".009","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"776800","CASS_NUM":"51671610","SMP_TAKEN_DT":"8/24/2026","CONC":".015","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-24"},{"SOURCE_ROW_NUMBER":"437456","CASS_NUM":"51671611","SMP_TAKEN_DT":"8/21/2026","CONC":".075","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-21"},{"SOURCE_ROW_NUMBER":"1139482","CASS_NUM":"51674662","SMP_TAKEN_DT":"8/20/2026","CONC":".078","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"1313126","CASS_NUM":"51674247","SMP_TAKEN_DT":"8/19/2026","CONC":".018","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"675620","CASS_NUM":"51674678","SMP_TAKEN_DT":"8/19/2026","CONC":".072","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTROL FILTER ABSENT","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-19"},{"SOURCE_ROW_NUMBER":"536520","CASS_NUM":"51674673","SMP_TAKEN_DT":"8/18/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-18"},{"SOURCE_ROW_NUMBER":"711046","CASS_NUM":"51674564","SMP_TAKEN_DT":"8/17/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"1039086","CASS_NUM":"51674668","SMP_TAKEN_DT":"8/14/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-14"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":11,"firstDate":"2012-08-15","lastDate":"2016-08-25","metrics":{"linkedIssuances":11},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":9,"firstDate":"2012-06-06","lastDate":"2012-06-20","metrics":{"decisions":9,"ssChanged":0,"recentRows":0,"decisionPenalty":147975,"proposedPenalty":345873},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"425536","CITATION_NO":"8000177","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-26","DECISION_DT":"01/08/2015","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"705.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"372277","CITATION_NO":"8000172","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-199","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"75.364(h)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"368001","CITATION_NO":"8000169","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-198","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"75.388(a)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"90700.00","DECISION_PENALTY_AMT":"70001.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"311692","CITATION_NO":"8000171","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-199","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"75.360(g)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"261014","CITATION_NO":"8000167","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-26","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"50.10(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":"1073.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"256494","CITATION_NO":"8000176","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-199","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"75.334(a)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"143038","CITATION_NO":"8000175","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-27","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"75.1714-2(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"91535","CITATION_NO":"8000174","CITATION_ISSUE_DT":"06/20/2012","DOCKET_NO":"PENN 2013-198","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"75.1202-1(b)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"90700.00","DECISION_PENALTY_AMT":"70001.00","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"87013","CITATION_NO":"8000173","CITATION_ISSUE_DT":"06/06/2012","DOCKET_NO":"PENN 2013-27","DECISION_DT":"01/08/2015","CFR_STANDARD_CODE":"75.1714-7(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2012-06-06"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2011-10-19","lastDate":"2013-02-27","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":157,"firstDate":"2011-11-15","lastDate":"2026-09-29","metrics":{"inspectors":246,"recentRows":57,"onSiteHours":3786.25,"inspectionHours":5723.5,"inspectionSamples":403},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"612453","EVENT_NO":"F04349B","INSPECTION_BEGIN_DT":"09/29/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"1080873","EVENT_NO":"F02A018","INSPECTION_BEGIN_DT":"08/03/2026","INSPECTION_END_DT":"08/06/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"35","SUM_TOTAL_ON_SITE_HOURS":"32.5","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"226123","EVENT_NO":"F02A019","INSPECTION_BEGIN_DT":"08/03/2026","INSPECTION_END_DT":"08/06/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"1104192","EVENT_NO":"F02620F","INSPECTION_BEGIN_DT":"04/08/2026","INSPECTION_END_DT":"04/21/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"21","sourceDate":"2026-04-08"},{"SOURCE_ROW_NUMBER":"867979","EVENT_NO":"F02A004","INSPECTION_BEGIN_DT":"04/08/2026","INSPECTION_END_DT":"04/20/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25.5","SUM_TOTAL_ON_SITE_HOURS":"20.5","sourceDate":"2026-04-08"},{"SOURCE_ROW_NUMBER":"919713","EVENT_NO":"F029FFD","INSPECTION_BEGIN_DT":"03/11/2026","INSPECTION_END_DT":"03/18/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-03-11"},{"SOURCE_ROW_NUMBER":"270005","EVENT_NO":"F029FFA","INSPECTION_BEGIN_DT":"02/25/2026","INSPECTION_END_DT":"03/11/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"42","SUM_TOTAL_ON_SITE_HOURS":"31.75","sourceDate":"2026-02-25"},{"SOURCE_ROW_NUMBER":"670282","EVENT_NO":"F029FF0","INSPECTION_BEGIN_DT":"01/21/2026","INSPECTION_END_DT":"01/26/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2026-01-21"},{"SOURCE_ROW_NUMBER":"645336","EVENT_NO":"F029056","INSPECTION_BEGIN_DT":"10/09/2025","INSPECTION_END_DT":"11/10/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"62.5","SUM_TOTAL_ON_SITE_HOURS":"46.25","sourceDate":"2025-10-09"},{"SOURCE_ROW_NUMBER":"758778","EVENT_NO":"F015AD4","INSPECTION_BEGIN_DT":"09/15/2025","INSPECTION_END_DT":"09/15/2025","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2025-09-15"},{"SOURCE_ROW_NUMBER":"492590","EVENT_NO":"F005600","INSPECTION_BEGIN_DT":"09/09/2025","INSPECTION_END_DT":"09/09/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2025-09-09"},{"SOURCE_ROW_NUMBER":"159333","EVENT_NO":"F015AD1","INSPECTION_BEGIN_DT":"08/25/2025","INSPECTION_END_DT":"09/15/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"10.75","sourceDate":"2025-08-25"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":116,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":1920,"employees":4,"production":1350},"2026-Q1":{"hours":1920,"employees":4,"production":1350},"2025-Q4":{"hours":1440,"employees":3,"production":900},"2025-Q3":{"hours":144,"employees":3,"production":90},"2025-Q2":{"hours":240,"employees":3,"production":100},"2025-Q1":{"hours":1440,"employees":3,"production":600},"2024-Q4":{"hours":360,"employees":3,"production":40},"2024-Q3":{"hours":200,"employees":2,"production":0},"2024-Q1":{"hours":1280,"employees":8,"production":3282},"2023-Q4":{"hours":4470,"employees":8,"production":7631},"2023-Q3":{"hours":4260,"employees":8,"production":6816},"2023-Q2":{"hours":4375,"employees":7,"production":4180}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":32,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":11602,"employees":5,"production":10487},"2018":{"hours":9506,"employees":5,"production":9049},"2019":{"hours":9411,"employees":5,"production":7498},"2020":{"hours":10057,"employees":6,"production":10281},"2021":{"hours":11255,"employees":6,"production":10087},"2022":{"hours":12916,"employees":6,"production":14568},"2023":{"hours":16535,"employees":8,"production":22417},"2024":{"hours":1840,"employees":6,"production":3322},"2025":{"hours":3264,"employees":3,"production":1690},"2026":{"hours":3840,"employees":4,"production":2700}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":66,"firstDate":"2012-02-07","lastDate":"2026-04-20","metrics":{"recentRows":25,"doseOver100":0,"actDoseTotal":937,"pelDoseTotal":489},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"177941","EVENT_NO":"F02620F","SURVEY_DATE":"04/20/2026","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-04-20"},{"SOURCE_ROW_NUMBER":"177944","EVENT_NO":"F029056","SURVEY_DATE":"11/10/2025","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"20","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2025-11-10"},{"SOURCE_ROW_NUMBER":"177943","EVENT_NO":"F029056","SURVEY_DATE":"10/14/2025","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"25","ACT_DOSE_85":"22","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2025-10-14"},{"SOURCE_ROW_NUMBER":"177942","EVENT_NO":"F029056","SURVEY_DATE":"10/14/2025","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"40","ACT_DOSE_85":"32","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2025-10-14"},{"SOURCE_ROW_NUMBER":"177940","EVENT_NO":"F009C88","SURVEY_DATE":"02/03/2025","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"20","ACT_DOSE_85":"1","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2025-02-03"},{"SOURCE_ROW_NUMBER":"177939","EVENT_NO":"F009C88","SURVEY_DATE":"01/23/2025","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2025-01-23"},{"SOURCE_ROW_NUMBER":"177938","EVENT_NO":"F009C88","SURVEY_DATE":"01/23/2025","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"20","ACT_DOSE_85":"4","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2025-01-23"},{"SOURCE_ROW_NUMBER":"177937","EVENT_NO":"4315012","SURVEY_DATE":"01/30/2024","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2024-01-30"},{"SOURCE_ROW_NUMBER":"177936","EVENT_NO":"4314699","SURVEY_DATE":"10/31/2023","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"10","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2023-10-31"},{"SOURCE_ROW_NUMBER":"177935","EVENT_NO":"4314699","SURVEY_DATE":"10/17/2023","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"25","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2023-10-17"},{"SOURCE_ROW_NUMBER":"177934","EVENT_NO":"4314699","SURVEY_DATE":"10/17/2023","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"20","ACT_DOSE_85":"1","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2023-10-17"},{"SOURCE_ROW_NUMBER":"177933","EVENT_NO":"4314699","SURVEY_DATE":"10/17/2023","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"20","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2023-10-17"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":8,"firstDate":"2014-11-17","lastDate":"2024-01-22","metrics":{"recentRows":1,"voidSamples":0,"maxQuartzPct":3.2,"validSamples":8,"quartzPctTotal":11.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"9700","CASSETTE_NO":"58529094","SAMPLE_DT":"01/22/2024","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2024-01-22"},{"SOURCE_ROW_NUMBER":"150249","CASSETTE_NO":"58341021","SAMPLE_DT":"10/19/2020","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-10-19"},{"SOURCE_ROW_NUMBER":"76759","CASSETTE_NO":"58342487","SAMPLE_DT":"07/13/2020","QUARTZ_PCT":"00.3","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-07-13"},{"SOURCE_ROW_NUMBER":"116277","CASSETTE_NO":"58258479","SAMPLE_DT":"04/11/2018","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-04-11"},{"SOURCE_ROW_NUMBER":"22672","CASSETTE_NO":"58260262","SAMPLE_DT":"02/22/2017","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-02-22"},{"SOURCE_ROW_NUMBER":"6670","CASSETTE_NO":"58276204","SAMPLE_DT":"10/20/2016","QUARTZ_PCT":"00.2","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-10-20"},{"SOURCE_ROW_NUMBER":"22935","CASSETTE_NO":"58199323","SAMPLE_DT":"03/07/2016","QUARTZ_PCT":"02.3","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-03-07"},{"SOURCE_ROW_NUMBER":"20696","CASSETTE_NO":"58110468","SAMPLE_DT":"11/17/2014","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":116,"firstDate":"2011-12-07","lastDate":"2026-09-29","metrics":{"ss":21,"amountDue":163823,"contested":0,"amountPaid":43978,"recentRows":24,"section104d":6,"unterminated":0,"proposedPenalty":361721},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1999391","VIOLATION_NO":"9606448","VIOLATION_ISSUE_DT":"09/29/2026","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/29/2026","CONTESTED_IND":"N","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"1999379","VIOLATION_NO":"9606441","VIOLATION_ISSUE_DT":"08/03/2026","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/03/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"1999334","VIOLATION_NO":"5155628","VIOLATION_ISSUE_DT":"04/20/2026","SIG_SUB":"N","PART_SECTION":"77.206(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/20/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-04-20"},{"SOURCE_ROW_NUMBER":"1999395","VIOLATION_NO":"9606289","VIOLATION_ISSUE_DT":"11/10/2025","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/10/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2025-11-10"},{"SOURCE_ROW_NUMBER":"1999389","VIOLATION_NO":"9606420","VIOLATION_ISSUE_DT":"08/25/2025","SIG_SUB":"N","PART_SECTION":"70.212(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/25/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2025-08-25"},{"SOURCE_ROW_NUMBER":"1999386","VIOLATION_NO":"9606419","VIOLATION_ISSUE_DT":"08/11/2025","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/11/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2025-08-11"},{"SOURCE_ROW_NUMBER":"1999324","VIOLATION_NO":"9603941","VIOLATION_ISSUE_DT":"04/23/2025","SIG_SUB":"N","PART_SECTION":"75.1312(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/23/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2025-04-23"},{"SOURCE_ROW_NUMBER":"1999303","VIOLATION_NO":"9603932","VIOLATION_ISSUE_DT":"02/03/2025","SIG_SUB":"N","PART_SECTION":"77.1102","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/03/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2025-02-03"},{"SOURCE_ROW_NUMBER":"1999301","VIOLATION_NO":"8005806","VIOLATION_ISSUE_DT":"01/23/2024","SIG_SUB":"N","PART_SECTION":"75.381(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/23/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2024-01-23"},{"SOURCE_ROW_NUMBER":"1999394","VIOLATION_NO":"8005803","VIOLATION_ISSUE_DT":"10/10/2023","SIG_SUB":"N","PART_SECTION":"75.1730(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/10/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2023-10-10"},{"SOURCE_ROW_NUMBER":"1999376","VIOLATION_NO":"8005318","VIOLATION_ISSUE_DT":"07/24/2023","SIG_SUB":"N","PART_SECTION":"75.333(c)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/24/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2023-07-24"},{"SOURCE_ROW_NUMBER":"1999329","VIOLATION_NO":"8005314","VIOLATION_ISSUE_DT":"04/12/2023","SIG_SUB":"N","PART_SECTION":"75.1100-2(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/12/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2023-04-12"}]}],"safety":{"href":"/api/v1/mines/3609963/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609963/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":5,"companyType":"Independent Producer Operator","components":[{"averageEmployees":5,"laborHours":1840,"mineType":"Underground","productionTons":3322}],"county":"Schuylkill","laborHours":1840,"mineName":"Slope #2","mineType":"Underground","mshaId":"3609963","operatingAddress":"15 Motter Drive, Pine Grove, PA 17963","operatingCompany":"S & J Coal Mine","operationType":"Mine only","productionTons":3322,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Pennsylvania (Anthracite)","status":"Active","supplyRegion":"Appalachia Northern","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.206","heading":"Ladders; construction; installation and maintenance.","id":"77.206","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.206","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Ladders shall be of substantial construction and maintained in good condition.\n\n(b) Wooden members of ladders shall not be painted.\n\n(c) Steep or vertical ladders which are used regularly at fixed locations shall be anchored securely and provided with backguards extending from a point not more than 7 feet from the bottom of the ladder to the top of the ladder.\n\n(d) Fixed ladders shall not incline backwards at any point unless provided with backguards.\n\n(e) Fixed ladders shall be anchored securely and installed to provide at least 3 inches of toe clearance.\n\n(f) Fixed ladders shall project at least 3 feet above landings, or substantial handholds shall be provided above the landings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Status change reports.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.212","part":"70","subchapter":"O","subpart":"C","id":"70.212","citation":"30 CFR 70.212","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Explosives and detonators in underground magazines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-N/section-75.1312","part":"75","subchapter":"O","subpart":"N","id":"75.1312","citation":"30 CFR 75.1312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Warning signs; smoking and open flame.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1102","part":"77","subchapter":"O","subpart":"L","id":"77.1102","citation":"30 CFR 77.1102","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Escapeways; anthracite mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.381","part":"75","subchapter":"O","subpart":"D","id":"75.381","citation":"30 CFR 75.381","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Compressed air; general; compressed air systems.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1730","part":"75","subchapter":"O","subpart":"R","id":"75.1730","citation":"30 CFR 75.1730","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609963","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}