{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3609694","name":"Mather Strip","status":"Abandoned","status_date":"2012-06-13","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Greene","nearest_town":"Nemacolin","operator_id":"0103425","operator_name":"Penn Development Services, L.P.","controller_id":"0087473","controller_name":"Donald R.  Gearhart","district":"C03","office":"Waynesburg PA Field Office","employees":0,"latitude":40.863889,"longitude":-79.397222},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":92},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609694","name":"Mather Strip"},"operator":{"type":"operator","id":"0103425","name":"Penn Development Services, L.P."},"controller":{"type":"controller","id":"0087473","name":"Donald R.  Gearhart"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0103425","name":"Penn Development Services, L.P."},"object":{"type":"mine","id":"3609694","name":"Mather Strip"},"validFrom":"2009-01-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609694|0103425|2009-01-07|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0087473","name":"Donald R.  Gearhart et al"},"object":{"type":"mine","id":"3609694","name":"Mather Strip"},"validFrom":"2009-01-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609694|0087473|2009-01-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0087473","name":"Donald R.  Gearhart et al"},"object":{"type":"operator","id":"0103425","name":"Penn Development Services, L.P."},"validFrom":"2009-01-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609694","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609694|0103425|2009-01-07|0087473|2009-01-07|14076"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-06-13","lastDate":"2012-06-13","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":15,"firstDate":"2010-09-08","lastDate":"2011-09-28","metrics":{"ss":4,"delinquent":15,"recentRows":0,"paidPenalty":1316,"proposedPenalty":5316,"currentAssessment":5316},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1638269","VIOLATION_NO":"7022683","ISSUE_DT":"09/28/2011","CFR_STANDARD_CD":"62.130(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"1638268","VIOLATION_NO":"7022682","ISSUE_DT":"09/27/2011","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-27"},{"SOURCE_ROW_NUMBER":"1638267","VIOLATION_NO":"7022681","ISSUE_DT":"09/27/2011","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-27"},{"SOURCE_ROW_NUMBER":"1638266","VIOLATION_NO":"7022678","ISSUE_DT":"09/12/2011","CFR_STANDARD_CD":"77.1713(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"2000.00","CURRENT_ASSESSMENT_AMT":"2000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"1638265","VIOLATION_NO":"7022677","ISSUE_DT":"09/12/2011","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2000.00","CURRENT_ASSESSMENT_AMT":"2000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"1637588","VIOLATION_NO":"7085837","ISSUE_DT":"09/08/2010","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1637587","VIOLATION_NO":"7084802","ISSUE_DT":"09/08/2010","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1637586","VIOLATION_NO":"7084174","ISSUE_DT":"09/08/2010","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1637585","VIOLATION_NO":"7084077","ISSUE_DT":"09/08/2010","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1637584","VIOLATION_NO":"7084076","ISSUE_DT":"09/08/2010","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1637583","VIOLATION_NO":"7084063","ISSUE_DT":"09/08/2010","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1637582","VIOLATION_NO":"7084059","ISSUE_DT":"09/08/2010","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-09-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2012-07-17","lastDate":"2012-07-17","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":4000,"originalPenalty":4000},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"314014","VIOLATION_NO":"7022678","DOCKET_NO":"PENN 2012-47","DECISION_DT":"07/17/2012","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-07-17"},{"SOURCE_ROW_NUMBER":"313338","VIOLATION_NO":"7022677","DOCKET_NO":"PENN 2012-47","DECISION_DT":"07/17/2012","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-07-17"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":10,"firstDate":"2010-09-08","lastDate":"2011-09-28","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":9,"maxConcentration":1.46,"concentrationTotal":3.684},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1515297","CASS_NUM":"57911581","SMP_TAKEN_DT":"9/28/2011","CONC":".103","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"680589","CASS_NUM":"57911569","SMP_TAKEN_DT":"9/28/2011","CONC":".076","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"645280","CASS_NUM":"57911548","SMP_TAKEN_DT":"9/28/2011","CONC":".268","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"548025","CASS_NUM":"57911563","SMP_TAKEN_DT":"9/28/2011","CONC":".381","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"94779","CASS_NUM":"57911547","SMP_TAKEN_DT":"9/28/2011","CONC":".583","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"1437282","CASS_NUM":"57579304","SMP_TAKEN_DT":"9/8/2010","CONC":".109","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"889312","CASS_NUM":"57579330","SMP_TAKEN_DT":"9/8/2010","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"666588","CASS_NUM":"57579313","SMP_TAKEN_DT":"9/8/2010","CONC":".529","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"478795","CASS_NUM":"57579277","SMP_TAKEN_DT":"9/8/2010","CONC":".175","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"BROKEN","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"94780","CASS_NUM":"57579310","SMP_TAKEN_DT":"9/8/2010","CONC":"1.46","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-09-08"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2,"firstDate":"2011-09-12","lastDate":"2011-09-12","metrics":{"decisions":2,"ssChanged":2,"recentRows":0,"decisionPenalty":4000,"proposedPenalty":4000},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"137966","CITATION_NO":"7022677","CITATION_ISSUE_DT":"09/12/2011","DOCKET_NO":"PENN 2012-47","DECISION_DT":"07/17/2012","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"27241","CITATION_NO":"7022678","CITATION_ISSUE_DT":"09/12/2011","DOCKET_NO":"PENN 2012-47","DECISION_DT":"07/17/2012","CFR_STANDARD_CODE":"77.1713(c)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2011-09-12"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2009-01-07","lastDate":"2009-01-07","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":6,"firstDate":"2010-08-24","lastDate":"2011-10-06","metrics":{"inspectors":7,"recentRows":0,"onSiteHours":54.5,"inspectionHours":86.75,"inspectionSamples":20},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1158184","EVENT_NO":"6222824","INSPECTION_BEGIN_DT":"10/06/2011","INSPECTION_END_DT":"10/06/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2011-10-06"},{"SOURCE_ROW_NUMBER":"978098","EVENT_NO":"6222820","INSPECTION_BEGIN_DT":"09/12/2011","INSPECTION_END_DT":"09/29/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"40","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"948734","EVENT_NO":"6222334","INSPECTION_BEGIN_DT":"02/03/2011","INSPECTION_END_DT":"03/30/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2011-02-03"},{"SOURCE_ROW_NUMBER":"527237","EVENT_NO":"6222328","INSPECTION_BEGIN_DT":"12/21/2010","INSPECTION_END_DT":"01/18/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2010-12-21"},{"SOURCE_ROW_NUMBER":"959429","EVENT_NO":"6222304","INSPECTION_BEGIN_DT":"08/30/2010","INSPECTION_END_DT":"09/13/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2010-08-30"},{"SOURCE_ROW_NUMBER":"1012535","EVENT_NO":"6222303","INSPECTION_BEGIN_DT":"08/24/2010","INSPECTION_END_DT":"08/24/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2010-08-24"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011-Q3":{"hours":7100,"employees":15,"production":29405},"2011-Q2":{"hours":7101,"employees":15,"production":18133},"2011-Q1":{"hours":1185,"employees":3,"production":6111},"2010-Q3":{"hours":1015,"employees":4,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010":{"hours":1015,"employees":4,"production":0},"2011":{"hours":15386,"employees":12,"production":53649}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2010-09-08","lastDate":"2011-09-28","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":666,"pelDoseTotal":391},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"176546","EVENT_NO":"6222820","SURVEY_DATE":"09/28/2011","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"275","PEL_DOSE_90":"263","SURVEY_TYPE":"I","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"176545","EVENT_NO":"6222820","SURVEY_DATE":"09/28/2011","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","MANUFACTURER_CD":"105","ACT_DOSE_85":"61","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"176544","EVENT_NO":"6222820","SURVEY_DATE":"09/28/2011","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"40","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"176543","EVENT_NO":"6222820","SURVEY_DATE":"09/28/2011","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"30","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"176542","EVENT_NO":"6222820","SURVEY_DATE":"09/28/2011","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"8","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"176541","EVENT_NO":"6222304","SURVEY_DATE":"09/08/2010","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"86","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"176540","EVENT_NO":"6222304","SURVEY_DATE":"09/08/2010","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"82","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"176539","EVENT_NO":"6222304","SURVEY_DATE":"09/08/2010","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"37","MANUFACTURER_CD":"018","ACT_DOSE_85":"34","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"176538","EVENT_NO":"6222304","SURVEY_DATE":"09/08/2010","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"105","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"176537","EVENT_NO":"6222304","SURVEY_DATE":"09/08/2010","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"48","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2010-09-08"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":3,"firstDate":"2010-09-08","lastDate":"2011-09-28","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":14.4,"validSamples":3,"quartzPctTotal":35.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"100017","CASSETTE_NO":"57911547","SAMPLE_DT":"09/28/2011","QUARTZ_PCT":"08.6","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"42335","CASSETTE_NO":"57579310","SAMPLE_DT":"09/08/2010","QUARTZ_PCT":"12.5","OCC_CODE_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"31284","CASSETTE_NO":"57579313","SAMPLE_DT":"09/08/2010","QUARTZ_PCT":"14.4","OCC_CODE_DESC":"BACKHOE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-09-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":15,"firstDate":"2010-09-08","lastDate":"2011-09-28","metrics":{"ss":4,"amountDue":5316,"contested":0,"amountPaid":1316,"recentRows":0,"section104d":2,"unterminated":0,"proposedPenalty":5316},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1994787","VIOLATION_NO":"7022683","VIOLATION_ISSUE_DT":"09/28/2011","SIG_SUB":"N","PART_SECTION":"62.130(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/05/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-09-28"},{"SOURCE_ROW_NUMBER":"1994786","VIOLATION_NO":"7022682","VIOLATION_ISSUE_DT":"09/27/2011","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/06/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-09-27"},{"SOURCE_ROW_NUMBER":"1994785","VIOLATION_NO":"7022681","VIOLATION_ISSUE_DT":"09/27/2011","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/27/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-09-27"},{"SOURCE_ROW_NUMBER":"1994784","VIOLATION_NO":"7022678","VIOLATION_ISSUE_DT":"09/12/2011","SIG_SUB":"N","PART_SECTION":"77.1713(c)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/13/2011","PROPOSED_PENALTY":"2000","AMOUNT_DUE":"2000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"1994783","VIOLATION_NO":"7022677","VIOLATION_ISSUE_DT":"09/12/2011","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/12/2011","PROPOSED_PENALTY":"2000","AMOUNT_DUE":"2000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"1994782","VIOLATION_NO":"7085837","VIOLATION_ISSUE_DT":"09/08/2010","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/09/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1994781","VIOLATION_NO":"7084802","VIOLATION_ISSUE_DT":"09/08/2010","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/09/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1994780","VIOLATION_NO":"7084174","VIOLATION_ISSUE_DT":"09/08/2010","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/08/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1994779","VIOLATION_NO":"7084077","VIOLATION_ISSUE_DT":"09/08/2010","SIG_SUB":"N","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/08/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1994778","VIOLATION_NO":"7084076","VIOLATION_ISSUE_DT":"09/08/2010","SIG_SUB":"Y","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/08/2010","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1994777","VIOLATION_NO":"7084063","VIOLATION_ISSUE_DT":"09/08/2010","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/13/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"1994776","VIOLATION_NO":"7084059","VIOLATION_ISSUE_DT":"09/08/2010","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/08/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-09-08"}]}],"safety":{"href":"/api/v1/mines/3609694/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609694/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 62.130","heading":"Permissible exposure level.","id":"62.130","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-M/part-62/section-62.130","part":"62","partHeading":"PART 62—OCCUPATIONAL NOISE EXPOSURE","subchapter":"M","subchapterHeading":"SUBCHAPTER M—UNIFORM MINE HEALTH REGULATIONS","subpart":"","subpartHeading":"","text":"(a) The mine operator must assure that no miner is exposed during any work shift to noise that exceeds the permissible exposure level. If during any work shift a miner's noise exposure exceeds the permissible exposure level, the mine operator must use all feasible engineering and administrative controls to reduce the miner's noise exposure to the permissible exposure level, and enroll the miner in a hearing conservation program that complies with § 62.150 of this part. When a mine operator uses administrative controls to reduce a miner's exposure, the mine operator must post the procedures for such controls on the mine bulletin board and provide a copy to the affected miner.\n\n(b) If a miner's noise exposure continues to exceed the permissible exposure level despite the use of all feasible engineering and administrative controls, the mine operator must continue to use the engineering and administrative controls to reduce the miner's noise exposure to as low a level as is feasible.\n\n(c) The mine operator must assure that no miner is exposed at any time to sound levels exceeding 115 dBA, as determined without adjustment for the use of any hearing protector.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1713","heading":"Daily inspection of surface coal mine; certified person; reports of inspection.","id":"77.1713","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1713","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) At least once during each working shift, or more often if necessary for safety, each active working area and each active surface installation shall be examined by a certified person designated by the operator to conduct such examinations for hazardous conditions and any hazardous conditions noted during such examinations shall be reported to the operator and shall be corrected by the operator.\n\n(b) If any hazardous condition noted during an examination conducted in accordance with paragraph (a) of this section creates an imminent danger, the person conducting such examination shall notify the operator and the operator shall withdraw all persons from the area affected, except those persons referred to in section 104(d) of the Act, until the danger is abated.\n\n(c) After each examination conducted in accordance with the provisions of paragraph (a) of this section, each certified person who conducted all or any part of the examination required shall enter with ink or indelible pencil in a book approved by the Secretary the date and a report of the condition of the mine or any area of the mine which he has inspected together with a report of the nature and location of any hazardous condition found to be present at the mine. The book in which such entries are made shall be kept in an area at the mine designated by the operator to minimize the danger of destruction by fire or other hazard.\n\n(d) All examination reports recorded in accordance with the provisions of paragraph (c) of this section shall include a report of the action taken to abate hazardous conditions and shall be signed or countersigned each day by at least one of the following persons:\n\n(1) The surface mine foreman;\n\n(2) The assistant superintendent of the mine;\n\n(3) The superintendent of the mine;\n\n(4) The person designated by the operator as responsible for health and safety at the mine; or,\n\n(5) An equivalent mine official.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995; 63 FR 58613, Oct. 30, 1998]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609694","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}