{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"3609637","name":"Starford Mine","status":"Abandoned","status_date":"2018-06-26","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Indiana","nearest_town":"Starford","operator_id":"P09635","operator_name":"Rosebud Mining Company","controller_id":"C07485","controller_name":"J Clifford  Forrest III","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":40.701389,"longitude":-78.953333},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1502},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609637","name":"Starford Mine"},"operator":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"controller":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"mine","id":"3609637","name":"Starford Mine"},"validFrom":"1979-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|C07485|1979-08-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14254","name":"John P  Garcia et al"},"object":{"type":"mine","id":"3609637","name":"Starford Mine"},"validFrom":"1999-04-01","validTo":"2010-03-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|C14254|1999-04-01|2010-03-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24141","name":"Parkwood Resources"},"object":{"type":"mine","id":"3609637","name":"Starford Mine"},"validFrom":"2008-06-17","validTo":"2010-04-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|P24141|2008-06-17|2010-04-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14254","name":"John P  Garcia et al"},"object":{"type":"operator","id":"P24141","name":"Parkwood Resources"},"validFrom":"2008-06-17","validTo":"2010-03-31","current":false,"derived":true,"evidenceMineId":"3609637","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|P24141|2008-06-17|C14254|1999-04-01|92369"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"mine","id":"3609637","name":"Starford Mine"},"validFrom":"2010-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|C07485|2010-04-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"operator","id":"P24141","name":"Parkwood Resources"},"validFrom":"2010-04-01","validTo":"2010-04-30","current":false,"derived":true,"evidenceMineId":"3609637","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|P24141|2008-06-17|C07485|2010-04-01|74860"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"object":{"type":"mine","id":"3609637","name":"Starford Mine"},"validFrom":"2010-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|P09635|2010-05-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"validFrom":"2010-05-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609637","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609637|P09635|2010-05-01|C07485|1979-08-01|74841"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":11,"firstDate":"2011-05-03","lastDate":"2016-03-28","metrics":{"daysLost":385,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"84584","DOCUMENT_NO":"220160960023","ACCIDENT_DT":"03/28/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"The employee was fueling EE's loader at the end of the shift. It was very windy and dust was blowing off the loader. EE apparently had some of the dirt blown into EE's eye. The dirt and rust particles were removed by an eye doctor.  There was no permanent damage to EE's eye.","sourceDate":"2016-03-28"},{"SOURCE_ROW_NUMBER":"196218","DOCUMENT_NO":"220160220009","ACCIDENT_DT":"01/14/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"The loader operator was getting off the CAT 992G loader at the end of the shift. EE stepped off the counter weight of the machine with EE's right foot onto a level berm.  EE stepped onto a piece of #3 stone causing EE's ankle to roll and EE fell to the ground.  EE was diagnosed with a sprained ankle.","sourceDate":"2016-01-14"},{"SOURCE_ROW_NUMBER":"20018","DOCUMENT_NO":"220143100006","ACCIDENT_DT":"10/29/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Roof Fall #3 Entry D Butt, Last open Xcut section","sourceDate":"2014-10-29"},{"SOURCE_ROW_NUMBER":"191966","DOCUMENT_NO":"220140550012","ACCIDENT_DT":"02/15/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"28","NARRATIVE":"Muddy - wet","sourceDate":"2014-02-15"},{"SOURCE_ROW_NUMBER":"222185","DOCUMENT_NO":"220140020004","ACCIDENT_DT":"12/23/2013","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Loose Rock","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"217937","DOCUMENT_NO":"220133080003","ACCIDENT_DT":"10/25/2013","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Loose rock","sourceDate":"2013-10-25"},{"SOURCE_ROW_NUMBER":"15740","DOCUMENT_NO":"220121210004","ACCIDENT_DT":"04/23/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"IGNITION OR EXPLOSION OF GAS OR DUST","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Methane","sourceDate":"2012-04-23"},{"SOURCE_ROW_NUMBER":"161996","DOCUMENT_NO":"220120890007","ACCIDENT_DT":"03/24/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Continuation of fall on 3-19-12","sourceDate":"2012-03-24"},{"SOURCE_ROW_NUMBER":"204956","DOCUMENT_NO":"220120860016","ACCIDENT_DT":"03/19/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof deteriorating","sourceDate":"2012-03-19"},{"SOURCE_ROW_NUMBER":"110149","DOCUMENT_NO":"220112100044","ACCIDENT_DT":"07/20/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"355","NARRATIVE":"Muddy, wet conditions - breaking chain while pulling shuttle car out striking him on thigh.","sourceDate":"2011-07-20"},{"SOURCE_ROW_NUMBER":"256652","DOCUMENT_NO":"220111290032","ACCIDENT_DT":"05/03/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall at face area #2 entry, 45' to 55' long, a-mains","sourceDate":"2011-05-03"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2018-06-26","lastDate":"2018-06-26","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":121,"firstDate":"2008-08-26","lastDate":"2015-07-29","metrics":{"ss":32,"delinquent":121,"recentRows":0,"paidPenalty":29048,"proposedPenalty":36427,"currentAssessment":29048},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1665070","VIOLATION_NO":"7032020","ISSUE_DT":"07/29/2015","CFR_STANDARD_CD":"75.1204","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-29"},{"SOURCE_ROW_NUMBER":"1663601","VIOLATION_NO":"7029649","ISSUE_DT":"11/21/2014","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-21"},{"SOURCE_ROW_NUMBER":"1663600","VIOLATION_NO":"7021896","ISSUE_DT":"11/19/2014","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-19"},{"SOURCE_ROW_NUMBER":"1663599","VIOLATION_NO":"7021895","ISSUE_DT":"11/19/2014","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-19"},{"SOURCE_ROW_NUMBER":"1655654","VIOLATION_NO":"7029975","ISSUE_DT":"09/24/2014","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"1664970","VIOLATION_NO":"7029927","ISSUE_DT":"09/17/2014","CFR_STANDARD_CD":"75.1103-5(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-17"},{"SOURCE_ROW_NUMBER":"1664969","VIOLATION_NO":"7029926","ISSUE_DT":"09/16/2014","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"1655653","VIOLATION_NO":"7021499","ISSUE_DT":"09/11/2014","CFR_STANDARD_CD":"75.350(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-11"},{"SOURCE_ROW_NUMBER":"1655652","VIOLATION_NO":"7021498","ISSUE_DT":"09/11/2014","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-11"},{"SOURCE_ROW_NUMBER":"1664968","VIOLATION_NO":"7029632","ISSUE_DT":"09/08/2014","CFR_STANDARD_CD":"75.523-3(b)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-08"},{"SOURCE_ROW_NUMBER":"1664967","VIOLATION_NO":"7029631","ISSUE_DT":"09/05/2014","CFR_STANDARD_CD":"77.1607(u)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"275.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-05"},{"SOURCE_ROW_NUMBER":"1664966","VIOLATION_NO":"7029630","ISSUE_DT":"09/05/2014","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"807.00","CURRENT_ASSESSMENT_AMT":"650.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-05"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":35,"firstDate":"2010-04-02","lastDate":"2015-08-26","metrics":{"appeals":0,"decisions":35,"recentRows":0,"decisionPenalty":18534,"originalPenalty":28733},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"150822","VIOLATION_NO":"7029617","DOCKET_NO":"PENN 2015-0158","DECISION_DT":"08/26/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"380.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-08-26"},{"SOURCE_ROW_NUMBER":"381225","VIOLATION_NO":"7027250","DOCKET_NO":"PENN 2014-0149","DECISION_DT":"06/29/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"2200.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-06-29"},{"SOURCE_ROW_NUMBER":"381224","VIOLATION_NO":"7027245","DOCKET_NO":"PENN 2014-0149","DECISION_DT":"06/29/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"9122.00","DECISION_PENALTY_AMT":"8000.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-06-29"},{"SOURCE_ROW_NUMBER":"148726","VIOLATION_NO":"7029631","DOCKET_NO":"PENN 2015-0056","DECISION_DT":"06/29/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"275.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-06-29"},{"SOURCE_ROW_NUMBER":"148725","VIOLATION_NO":"7029630","DOCKET_NO":"PENN 2015-0056","DECISION_DT":"06/29/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"650.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-06-29"},{"SOURCE_ROW_NUMBER":"148724","VIOLATION_NO":"7027348","DOCKET_NO":"PENN 2015-0056","DECISION_DT":"06/29/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"108.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-06-29"},{"SOURCE_ROW_NUMBER":"390330","VIOLATION_NO":"7029625","DOCKET_NO":"PENN 2015-0025","DECISION_DT":"04/20/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1026.00","DECISION_PENALTY_AMT":"718.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-04-20"},{"SOURCE_ROW_NUMBER":"383728","VIOLATION_NO":"7019634","DOCKET_NO":"PENN 2014-0833","DECISION_DT":"03/18/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"108.00","DECISION_PENALTY_AMT":"108.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"141546","VIOLATION_NO":"7019631","DOCKET_NO":"PENN 2014-0833","DECISION_DT":"03/18/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"170.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"143193","VIOLATION_NO":"8011266","DOCKET_NO":"PENN 2014-0883","DECISION_DT":"12/08/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"207.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"380581","VIOLATION_NO":"7027229","DOCKET_NO":"PENN 2014-91","DECISION_DT":"09/19/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"374.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-09-19"},{"SOURCE_ROW_NUMBER":"137278","VIOLATION_NO":"7027232","DOCKET_NO":"PENN 2014-91","DECISION_DT":"09/19/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"199.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2014-09-19"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":219,"firstDate":"2008-07-23","lastDate":"2016-06-07","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":19,"validSamples":200,"maxConcentration":1.523,"concentrationTotal":69.535},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1457999","CASS_NUM":"58244427","SMP_TAKEN_DT":"6/7/2016","CONC":".054","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-06-07"},{"SOURCE_ROW_NUMBER":"1271882","CASS_NUM":"58244653","SMP_TAKEN_DT":"6/7/2016","CONC":".022","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-06-07"},{"SOURCE_ROW_NUMBER":"1094194","CASS_NUM":"58244654","SMP_TAKEN_DT":"6/7/2016","CONC":".537","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-06-07"},{"SOURCE_ROW_NUMBER":"931214","CASS_NUM":"58244409","SMP_TAKEN_DT":"6/7/2016","CONC":".026","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-06-07"},{"SOURCE_ROW_NUMBER":"907394","CASS_NUM":"58244450","SMP_TAKEN_DT":"6/7/2016","CONC":".026","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-06-07"},{"SOURCE_ROW_NUMBER":"244929","CASS_NUM":"58244638","SMP_TAKEN_DT":"6/7/2016","CONC":".011","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-06-07"},{"SOURCE_ROW_NUMBER":"1573129","CASS_NUM":"58229396","SMP_TAKEN_DT":"12/15/2015","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"787949","CASS_NUM":"58229175","SMP_TAKEN_DT":"12/15/2015","CONC":".011","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"754262","CASS_NUM":"58229391","SMP_TAKEN_DT":"12/15/2015","CONC":".005","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"345932","CASS_NUM":"58229394","SMP_TAKEN_DT":"12/15/2015","CONC":".008","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"62104","CASS_NUM":"58229174","SMP_TAKEN_DT":"12/15/2015","CONC":".003","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"1041611","CASS_NUM":"58228928","SMP_TAKEN_DT":"8/11/2015","CONC":".004","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-08-11"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2010-04-02","lastDate":"2010-04-02","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":35,"firstDate":"2008-08-26","lastDate":"2014-09-05","metrics":{"decisions":35,"ssChanged":11,"recentRows":0,"decisionPenalty":18534,"proposedPenalty":28733},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"433055","CITATION_NO":"7029630","CITATION_ISSUE_DT":"09/05/2014","DOCKET_NO":"PENN 2015-0056","DECISION_DT":"06/29/2015","CFR_STANDARD_CODE":"75.904","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"650.00","sourceDate":"2014-09-05"},{"SOURCE_ROW_NUMBER":"95560","CITATION_NO":"7029631","CITATION_ISSUE_DT":"09/05/2014","DOCKET_NO":"PENN 2015-0056","DECISION_DT":"06/29/2015","CFR_STANDARD_CODE":"77.1607(u)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"275.00","sourceDate":"2014-09-05"},{"SOURCE_ROW_NUMBER":"320046","CITATION_NO":"7029625","CITATION_ISSUE_DT":"08/05/2014","DOCKET_NO":"PENN 2015-0025","DECISION_DT":"04/20/2015","CFR_STANDARD_CODE":"75.1714-4(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1026.00","DECISION_PENALTY_AMT":"718.00","sourceDate":"2014-08-05"},{"SOURCE_ROW_NUMBER":"377774","CITATION_NO":"7029617","CITATION_ISSUE_DT":"07/07/2014","DOCKET_NO":"PENN 2015-0158","DECISION_DT":"08/26/2015","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"380.00","sourceDate":"2014-07-07"},{"SOURCE_ROW_NUMBER":"178754","CITATION_NO":"8011266","CITATION_ISSUE_DT":"04/25/2014","DOCKET_NO":"PENN 2014-0883","DECISION_DT":"12/08/2014","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"207.00","sourceDate":"2014-04-25"},{"SOURCE_ROW_NUMBER":"152421","CITATION_NO":"7027348","CITATION_ISSUE_DT":"04/09/2014","DOCKET_NO":"PENN 2015-0056","DECISION_DT":"06/29/2015","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"108.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2014-04-09"},{"SOURCE_ROW_NUMBER":"265097","CITATION_NO":"7019634","CITATION_ISSUE_DT":"01/31/2014","DOCKET_NO":"PENN 2014-0833","DECISION_DT":"03/18/2015","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"108.00","DECISION_PENALTY_AMT":"108.00","sourceDate":"2014-01-31"},{"SOURCE_ROW_NUMBER":"202875","CITATION_NO":"7019631","CITATION_ISSUE_DT":"01/31/2014","DOCKET_NO":"PENN 2014-0833","DECISION_DT":"03/18/2015","CFR_STANDARD_CODE":"75.1100-2(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"170.00","sourceDate":"2014-01-31"},{"SOURCE_ROW_NUMBER":"373202","CITATION_NO":"7027250","CITATION_ISSUE_DT":"12/27/2013","DOCKET_NO":"PENN 2014-0149","DECISION_DT":"06/29/2015","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"2200.00","sourceDate":"2013-12-27"},{"SOURCE_ROW_NUMBER":"91697","CITATION_NO":"7027245","CITATION_ISSUE_DT":"12/04/2013","DOCKET_NO":"PENN 2014-0149","DECISION_DT":"06/29/2015","CFR_STANDARD_CODE":"75.321(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"9122.00","DECISION_PENALTY_AMT":"8000.00","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"429580","CITATION_NO":"7027240","CITATION_ISSUE_DT":"11/21/2013","DOCKET_NO":"PENN 2014-126","DECISION_DT":"06/23/2014","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"1111.00","sourceDate":"2013-11-21"},{"SOURCE_ROW_NUMBER":"147962","CITATION_NO":"7027239","CITATION_ISSUE_DT":"11/20/2013","DOCKET_NO":"PENN 2014-126","DECISION_DT":"06/23/2014","CFR_STANDARD_CODE":"77.202","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"150.00","sourceDate":"2013-11-20"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":597,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":144,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2008-06-17","lastDate":"2010-05-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":140,"firstDate":"2008-07-22","lastDate":"2018-06-26","metrics":{"inspectors":207,"recentRows":0,"onSiteHours":2546.75,"inspectionHours":3917.75,"inspectionSamples":431},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"113818","EVENT_NO":"6243797","INSPECTION_BEGIN_DT":"06/26/2018","INSPECTION_END_DT":"06/26/2018","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2018-06-26"},{"SOURCE_ROW_NUMBER":"518377","EVENT_NO":"6243648","INSPECTION_BEGIN_DT":"01/25/2017","INSPECTION_END_DT":"01/25/2017","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2017-01-25"},{"SOURCE_ROW_NUMBER":"951563","EVENT_NO":"6243632","INSPECTION_BEGIN_DT":"10/19/2016","INSPECTION_END_DT":"10/19/2016","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2016-10-19"},{"SOURCE_ROW_NUMBER":"1305","EVENT_NO":"6243610","INSPECTION_BEGIN_DT":"07/05/2016","INSPECTION_END_DT":"07/19/2016","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2016-07-05"},{"SOURCE_ROW_NUMBER":"919746","EVENT_NO":"6242389","INSPECTION_BEGIN_DT":"06/28/2016","INSPECTION_END_DT":"07/06/2016","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.25","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2016-06-28"},{"SOURCE_ROW_NUMBER":"458710","EVENT_NO":"6243602","INSPECTION_BEGIN_DT":"06/01/2016","INSPECTION_END_DT":"06/08/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"34.5","SUM_TOTAL_ON_SITE_HOURS":"19","sourceDate":"2016-06-01"},{"SOURCE_ROW_NUMBER":"1056490","EVENT_NO":"6243356","INSPECTION_BEGIN_DT":"12/15/2015","INSPECTION_END_DT":"01/21/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.5","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"637337","EVENT_NO":"6243076","INSPECTION_BEGIN_DT":"07/08/2015","INSPECTION_END_DT":"08/27/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"31","SUM_TOTAL_ON_SITE_HOURS":"20.5","sourceDate":"2015-07-08"},{"SOURCE_ROW_NUMBER":"768410","EVENT_NO":"6242996","INSPECTION_BEGIN_DT":"06/11/2015","INSPECTION_END_DT":"06/11/2015","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2015-06-11"},{"SOURCE_ROW_NUMBER":"804331","EVENT_NO":"6243120","INSPECTION_BEGIN_DT":"04/23/2015","INSPECTION_END_DT":"06/17/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2015-04-23"},{"SOURCE_ROW_NUMBER":"161001","EVENT_NO":"6242979","INSPECTION_BEGIN_DT":"03/20/2015","INSPECTION_END_DT":"03/20/2015","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2015-03-20"},{"SOURCE_ROW_NUMBER":"50457","EVENT_NO":"6242967","INSPECTION_BEGIN_DT":"01/02/2015","INSPECTION_END_DT":"02/26/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2015-01-02"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":11,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009":{"hours":80,"employees":2,"production":2256},"2011":{"hours":60248,"employees":29,"production":93393},"2012":{"hours":33347,"employees":16,"production":72600},"2013":{"hours":20753,"employees":15,"production":34491},"2014":{"hours":61561,"employees":24,"production":60095},"2015":{"hours":1911,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":55,"firstDate":"2008-07-22","lastDate":"2015-12-15","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":2973,"pelDoseTotal":2066},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"176225","EVENT_NO":"6243356","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"18","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"176224","EVENT_NO":"6243356","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"18","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"176223","EVENT_NO":"6243356","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"58","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"176222","EVENT_NO":"6243356","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"52","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"176221","EVENT_NO":"6243356","SURVEY_DATE":"12/15/2015","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"48","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2015-12-15"},{"SOURCE_ROW_NUMBER":"176220","EVENT_NO":"6242355","SURVEY_DATE":"11/05/2014","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"39","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"176219","EVENT_NO":"6242355","SURVEY_DATE":"11/05/2014","OCCUPATION_CD_DESC":"FORKLIFT OPERATOR","MACHINE_CD":"17","MANUFACTURER_CD":"017","ACT_DOSE_85":"29","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"176218","EVENT_NO":"6242073","SURVEY_DATE":"12/04/2013","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"38","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"176217","EVENT_NO":"6242073","SURVEY_DATE":"12/04/2013","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"119","ACT_DOSE_85":"51","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"176216","EVENT_NO":"6242073","SURVEY_DATE":"12/04/2013","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"119","ACT_DOSE_85":"89","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"176215","EVENT_NO":"6242073","SURVEY_DATE":"12/04/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"85","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2013-12-04"},{"SOURCE_ROW_NUMBER":"176214","EVENT_NO":"6242073","SURVEY_DATE":"12/04/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"74","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2013-12-04"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":1,"firstDate":"2014-04-15","lastDate":"2014-04-15","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":2.6,"validSamples":1,"quartzPctTotal":2.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"86958","CASSETTE_NO":"58132704","SAMPLE_DT":"04/15/2014","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-04-15"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":127,"firstDate":"2008-08-26","lastDate":"2015-07-29","metrics":{"ss":32,"amountDue":29048,"contested":4,"amountPaid":29048,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":36427},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1994014","VIOLATION_NO":"7032020","VIOLATION_ISSUE_DT":"07/29/2015","SIG_SUB":"N","PART_SECTION":"75.1204","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/10/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-07-29"},{"SOURCE_ROW_NUMBER":"1994044","VIOLATION_NO":"7029649","VIOLATION_ISSUE_DT":"11/21/2014","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/25/2014","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2014-11-21"},{"SOURCE_ROW_NUMBER":"1994043","VIOLATION_NO":"7021896","VIOLATION_ISSUE_DT":"11/19/2014","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/19/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-11-19"},{"SOURCE_ROW_NUMBER":"1994042","VIOLATION_NO":"7021895","VIOLATION_ISSUE_DT":"11/19/2014","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/19/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-11-19"},{"SOURCE_ROW_NUMBER":"1994065","VIOLATION_NO":"7029644","VIOLATION_ISSUE_DT":"10/30/2014","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"11/07/2014","CONTESTED_IND":"N","sourceDate":"2014-10-30"},{"SOURCE_ROW_NUMBER":"1994039","VIOLATION_NO":"7029975","VIOLATION_ISSUE_DT":"09/24/2014","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/24/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"1994013","VIOLATION_NO":"7029927","VIOLATION_ISSUE_DT":"09/17/2014","SIG_SUB":"N","PART_SECTION":"75.1103-5(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-09-17"},{"SOURCE_ROW_NUMBER":"1994012","VIOLATION_NO":"7029926","VIOLATION_ISSUE_DT":"09/16/2014","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/16/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-09-16"},{"SOURCE_ROW_NUMBER":"1994038","VIOLATION_NO":"7021499","VIOLATION_ISSUE_DT":"09/11/2014","SIG_SUB":"N","PART_SECTION":"75.350(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/11/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-09-11"},{"SOURCE_ROW_NUMBER":"1994037","VIOLATION_NO":"7021498","VIOLATION_ISSUE_DT":"09/11/2014","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/11/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-09-11"},{"SOURCE_ROW_NUMBER":"1994011","VIOLATION_NO":"7029632","VIOLATION_ISSUE_DT":"09/08/2014","SIG_SUB":"N","PART_SECTION":"75.523-3(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-09-08"},{"SOURCE_ROW_NUMBER":"1994010","VIOLATION_NO":"7029631","VIOLATION_ISSUE_DT":"09/05/2014","SIG_SUB":"Y","PART_SECTION":"77.1607(u)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/08/2014","PROPOSED_PENALTY":"362","AMOUNT_DUE":"275","AMOUNT_PAID":"275","CONTESTED_IND":"N","sourceDate":"2014-09-05"}]}],"safety":{"href":"/api/v1/mines/3609637/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609637/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Mine closure; filing of map with Secretary.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1204","part":"75","subchapter":"O","subpart":"M","id":"75.1204","citation":"30 CFR 75.1204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-5","heading":"Automatic fire warning devices; actions and response.","id":"75.1103-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) When the carbon monoxide level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following locations:\n\n(1) At working sections and other work locations where miners may be endangered from a fire in the belt entry.\n\n(2) At a manned surface location where personnel have an assigned post of duty. The manned surface location must have:\n\n(i) A telephone or equivalent communication with all miners who may be endangered and\n\n(ii) A map or schematic that shows the locations of sensors, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(3) The automatic fire sensor and warning device system shall be monitored for a period of 4 hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in § 75.1103-4(e).\n\n(b) The fire sensor and warning device system shall include a means for rapid evaluation of electrical short and open circuits, ground faults, pneumatic leaks, or other defect detrimental to its proper operational condition.\n\n(c) Automatic fire sensor and warning devices shall include a manual reset feature.\n\n(d) When a malfunction or warning signal is received at the manned surface location, the sensors that are activated must be identified and appropriate personnel immediately notified.\n\n(e) Upon notification of a malfunction or warning signal, appropriate personnel must immediately initiate an investigation to determine the cause of the malfunction or warning signal and take the required actions set forth in paragraph (f) of this section.\n\n(f) If any sensor indicates a warning, the following actions must be taken unless the mine operator determines that the signal does not present a hazard to miners:\n\n(1) Appropriate personnel must notify miners in affected working sections, in affected areas where mechanized mining equipment is being installed or removed, and at other locations specified in the approved mine emergency evacuation and firefighting program of instruction; and\n\n(2) All miners in the affected areas, unless assigned emergency response duties, must be immediately withdrawn to a safe location identified in the mine emergency evacuation and firefighting program of instruction.\n\n(g) If the warning signal will be activated during calibration of sensors, personnel manning the surface location must be notified prior to and upon completion of calibration. Affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction must be notified at the beginning and completion of calibration.\n\n(h) If any fire detection component becomes inoperative, immediate action must be taken to repair the component. While repairs are being made, operation of the belt may continue if the following requirements are met:\n\n(1) If one sensor becomes inoperative, a trained person must continuously monitor for carbon monoxide at the inoperative sensor;\n\n(2) If two or more adjacent sensors become inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety. Alternatively, a trained person must be stationed at each inoperative sensor to monitor for carbon monoxide;\n\n(3) If the complete fire detection system becomes inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety;\n\n(4) Trained persons who conduct monitoring under this section must have two-way voice communication capability, at intervals not to exceed 2,000 feet, and must report carbon monoxide concentrations to the surface at intervals not to exceed one hour;\n\n(5) Trained persons who conduct monitoring under this section must immediately report to the surface any concentration of carbon monoxide that reaches 10 parts per million above the established ambient level, unless the mine operator knows that the source of the carbon monoxide does not present a hazard to miners; and\n\n(6) Handheld detectors used to monitor the belt entry under this section must have a detection level equivalent to that of the system's carbon monoxide sensors.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","heading":"Belt air course ventilation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.350","part":"75","subchapter":"O","subpart":"D","id":"75.350","citation":"30 CFR 75.350","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1607","heading":"Loading and haulage equipment; operation.","id":"77.1607","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1607","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Vehicles shall follow at a safe distance; passing shall be limited to areas of adequate clearance and visibility.\n\n(b) Mobile equipment operators shall have full control of the equipment while it is in motion.\n\n(c) Equipment operating speeds shall be prudent and consistent with conditions of roadway, grades, clearance, visibility, traffic, and the type of equipment used.\n\n(d) Cabs of mobile equipment shall be kept free of extraneous materials.\n\n(e) Operators shall sit facing the direction of travel while operating equipment with dual controls.\n\n(f) When an equipment operator is present, men shall notify him before getting on or off equipment.\n\n(g) Equipment operators shall be certain, by signal or other means, that all persons are clear before starting or moving equipment.\n\n(h) Where possible, aerial tramways shall not be started until the tramway operator has ascertained that everyone is in the clear.\n\n(i) Dust control measures shall be taken where dust significantly reduces visibility of equipment operators.\n\n(j) Dippers, buckets, loading booms, or heavy suspended loads shall not be swung over the cabs of haulage vehicles until the drivers are out of the cabs and in safe locations, unless the trucks are designed specifically to protect the drivers from falling material.\n\n(k) Men shall not work or pass under the buckets or booms of loaders in operation.\n\n(l) Tires shall be deflated before repairs on them are started and adequate means shall be provided to prevent wheel locking rims from creating a hazard during tire inflation.\n\n(m) Electrically powered mobile equipment shall not be left unattended unless the master switch is in the off position, all operating controls are in the neutral position, and the brakes are set or other equivalent precautions are taken against rolling.\n\n(n) Mobile equipment shall not be left unattended unless the brakes are set. The wheels shall be turned into a bank or berm, or shall be blocked, when such equipment is parked on a grade.\n\n(o) Lights, flares, or other warning devices shall be posted when parked equipment creates a hazard to vehicular traffic.\n\n(p) Dippers, buckets, scraper blades, and similar movable parts shall be secured or lowered to the ground when not in use.\n\n(q) Shovel trailing cables shall not be moved with the shovel dipper unless cable slings or sleds are used.\n\n(r) Equipment which is to be hauled shall be loaded and protected so as to prevent sliding or spillage.\n\n(s) When moving between work areas, the equipment shall be secured in the travel position.\n\n(t) Any load extending more than 4 feet beyond the rear of the vehicle body should be marked clearly with a red flag by day and a red light at night.\n\n(u) Tow bars shall be used to tow heavy equipment and a safety chain shall be used in conjunction with each tow bar.\n\n(v) Railroad cars shall be kept under control at all times by the car dropper. Cars shall be dropped at a safe rate and in a manner that will insure that the car dropper maintains a safe position while working and traveling around the cars.\n\n(w) Railroad cars shall not be coupled or uncoupled manually from the inside of curves unless the railroad and cars are so designed to eliminate any hazard from coupling or uncoupling cars from inside of curves.\n\n(x) Persons shall wear safety belts when dropping railroad cars.\n\n(y) Railcars shall not be left on sidetracks unless ample clearance is provided for traffic on adjacent tracks.\n\n(z) Parked railcars, unless held effectively by brakes, shall be blocked securely.\n\n(aa) Railroad cars and all trucks shall be trimmed properly when they have been loaded higher than the confines of their cargo space.\n\n(bb) When the entire length of a conveyor is visible from the starting switch, the operator shall visually check to make certain that all persons are in the clear before starting the conveyor. When the entire length of the conveyor is not visible from the starting switch, a positive audible or visible warning system shall be installed and operated to warn persons that the conveyor will be started.\n\n(cc) Unguarded conveyors with walkways shall be equipped with emergency stop devices or cords along their full length.\n\n(dd) Adequate backstops or brakes shall be installed on inclined-conveyor drive units to prevent conveyors from running in reverse if a hazard to personnel would be caused.\n\n(ee) Aerial tram conveyor buckets shall not be overloaded, and feed shall be regulated to prevent spillage.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609637","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}