{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"3609549","name":"Kimberly Run","status":"Abandoned","status_date":"2020-09-02","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Somerset","nearest_town":"Somerset","operator_id":"P24228","operator_name":"RoxCoal, Inc.","controller_id":"0077457","controller_name":"Quintana Capital Group GP Ltd","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":39.996111,"longitude":-78.996944},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":6586},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609549","name":"Kimberly Run"},"operator":{"type":"operator","id":"P24228","name":"RoxCoal, Inc."},"controller":{"type":"controller","id":"0077457","name":"Quintana Capital Group GP Ltd"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15843","name":"Severstal Resources"},"object":{"type":"mine","id":"3609549","name":"Kimberly Run"},"validFrom":"1998-03-06","validTo":"2014-08-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609549|C15843|1998-03-06|2014-08-19"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24228","name":"RoxCoal, Inc."},"object":{"type":"mine","id":"3609549","name":"Kimberly Run"},"validFrom":"2007-08-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609549|P24228|2007-08-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15843","name":"Severstal Resources"},"object":{"type":"operator","id":"P24228","name":"RoxCoal, Inc."},"validFrom":"2007-08-15","validTo":"2014-08-19","current":false,"derived":true,"evidenceMineId":"3609549","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609549|P24228|2007-08-15|C15843|1998-03-06|97114"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0077457","name":"Quintana Capital Group GP Ltd et al"},"object":{"type":"mine","id":"3609549","name":"Kimberly Run"},"validFrom":"2014-08-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609549|0077457|2014-08-20|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0077457","name":"Quintana Capital Group GP Ltd et al"},"object":{"type":"operator","id":"P24228","name":"RoxCoal, Inc."},"validFrom":"2014-08-20","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609549","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609549|P24228|2007-08-15|0077457|2014-08-20|12203"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":96,"firstDate":"2008-05-30","lastDate":"2014-11-17","metrics":{"daysLost":2204,"injuries":86,"fatalities":0,"recentRows":0,"restrictedDays":1099,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"252339","DOCUMENT_NO":"220143230015","ACCIDENT_DT":"11/17/2014","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was lifting pump off of a cart. Didn't see he was standing on pump cable. When he twisted to walk with the pump, cable pulled pump which caused employee's back to twist.","sourceDate":"2014-11-17"},{"SOURCE_ROW_NUMBER":"170631","DOCUMENT_NO":"220142940021","ACCIDENT_DT":"10/14/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Roof fall occurred in an outby area. Approximately 30' long x 20' wide x 8-10' high. Did not affect any escapeway or ventilation.","sourceDate":"2014-10-14"},{"SOURCE_ROW_NUMBER":"179227","DOCUMENT_NO":"220142510054","ACCIDENT_DT":"09/04/2014","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Pulling bolter cable from reel felt pain in shoulder.","sourceDate":"2014-09-04"},{"SOURCE_ROW_NUMBER":"230833","DOCUMENT_NO":"220142310031","ACCIDENT_DT":"08/12/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The man was changing scoop batteries. The man was removing the scoop cable plug which was tight in the connection. While pulling with force on the plug, it suddenly came loose and struck the man on the lip. Medical Report Only(sutures)","sourceDate":"2014-08-12"},{"SOURCE_ROW_NUMBER":"62944","DOCUMENT_NO":"220142240011","ACCIDENT_DT":"08/01/2014","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"42","NARRATIVE":"The man was loading belt structure into a scoop bucket when he felt a pain in his lower abdomen.","sourceDate":"2014-08-01"},{"SOURCE_ROW_NUMBER":"110148","DOCUMENT_NO":"220142170031","ACCIDENT_DT":"07/31/2014","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Unclassified, insufficient data","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The man complained of a persistent pain in his knee. He was unaware of any specific incident that caused it.","sourceDate":"2014-07-31"},{"SOURCE_ROW_NUMBER":"204953","DOCUMENT_NO":"220142130056","ACCIDENT_DT":"07/24/2014","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"49","NARRATIVE":"The roof bolter stood on the head of bolter to insert resin and bolt in a 9 ft high area. He asked another operator to raise wrench up with head to push the bolt into roof. After pushing the bolt up, the assisting operator began lowering the head. The victim's foot which was still on the drill head frame became pinched between the frame and hydraulic fitting of the machine.","sourceDate":"2014-07-24"},{"SOURCE_ROW_NUMBER":"256650","DOCUMENT_NO":"220141750017","ACCIDENT_DT":"06/20/2014","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The man was sitting on the mantrip. As the mantrip began to move, he noticed the lunch bag on top of the mantrip was rubbing against the roof. He stated he told the operator to stop and reached for the bag. The operator did not hear him and continued to tram. The mantrip struck a rock causing the man's arm to momentarily be pinched between the mantrip and the roof.","sourceDate":"2014-06-20"},{"SOURCE_ROW_NUMBER":"252338","DOCUMENT_NO":"220141610021","ACCIDENT_DT":"06/05/2014","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The man was carrying a 5 gallon container of oil on the top of his shoulder. When he bent over, the oil can shifted and the man reported feeling a pain in his low back area.","sourceDate":"2014-06-05"},{"SOURCE_ROW_NUMBER":"149142","DOCUMENT_NO":"220141480019","ACCIDENT_DT":"05/21/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The man was tightening a bolt on a shuttle car. As he twisted the wrench, his hand rubbed against a piece of metal lacerating it. The man first went for treatment on 5/22/2014. Report Filed for Medical Treatment Only (stitches)","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"265278","DOCUMENT_NO":"220141250032","ACCIDENT_DT":"04/29/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The man had changed the blade on his utility knife the previous shift and forgot to retract the blade. As he was beginning his next shift he reached for his knife and slid his finger across the blade cutting his finger. Report Filed For Medical Treatment Only (sutures)","sourceDate":"2014-04-29"},{"SOURCE_ROW_NUMBER":"71547","DOCUMENT_NO":"220141200008","ACCIDENT_DT":"04/23/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the NW-B section (MMU 001-0) in #1 to #0 crosscut between survey station 7219 and survey station 7185. The fall was approximately 50 feet long x 20 feet wide x 8-10 feet high.","sourceDate":"2014-04-23"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-09-02","lastDate":"2020-09-02","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1011,"firstDate":"2008-04-15","lastDate":"2019-03-18","metrics":{"ss":174,"delinquent":1010,"recentRows":0,"paidPenalty":317185,"proposedPenalty":483564,"currentAssessment":317185},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1634541","VIOLATION_NO":"9200016","ISSUE_DT":"03/18/2019","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-03-18"},{"SOURCE_ROW_NUMBER":"1634540","VIOLATION_NO":"9200015","ISSUE_DT":"03/18/2019","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-03-18"},{"SOURCE_ROW_NUMBER":"1660409","VIOLATION_NO":"9077797","ISSUE_DT":"08/17/2017","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-08-17"},{"SOURCE_ROW_NUMBER":"1659914","VIOLATION_NO":"9071558","ISSUE_DT":"03/01/2017","CFR_STANDARD_CD":"77.1713(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"1659913","VIOLATION_NO":"9071557","ISSUE_DT":"03/01/2017","CFR_STANDARD_CD":"77.1109(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"259.00","CURRENT_ASSESSMENT_AMT":"259.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"681767","VIOLATION_NO":"7032742","ISSUE_DT":"04/27/2015","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-04-27"},{"SOURCE_ROW_NUMBER":"681766","VIOLATION_NO":"7032741","ISSUE_DT":"04/23/2015","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-04-23"},{"SOURCE_ROW_NUMBER":"681765","VIOLATION_NO":"7032737","ISSUE_DT":"04/09/2015","CFR_STANDARD_CD":"75.1502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-04-09"},{"SOURCE_ROW_NUMBER":"681344","VIOLATION_NO":"8006153","ISSUE_DT":"01/06/2015","CFR_STANDARD_CD":"75.364(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-01-06"},{"SOURCE_ROW_NUMBER":"681343","VIOLATION_NO":"8006152","ISSUE_DT":"01/06/2015","CFR_STANDARD_CD":"75.364(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-01-06"},{"SOURCE_ROW_NUMBER":"681342","VIOLATION_NO":"8006151","ISSUE_DT":"11/25/2014","CFR_STANDARD_CD":"75.380(d)(7)(vi)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-25"},{"SOURCE_ROW_NUMBER":"681341","VIOLATION_NO":"7028900","ISSUE_DT":"11/24/2014","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-11-24"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":256,"firstDate":"2009-10-15","lastDate":"2016-01-15","metrics":{"appeals":0,"decisions":256,"recentRows":0,"decisionPenalty":148041,"originalPenalty":358418},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"395027","VIOLATION_NO":"7028883","DOCKET_NO":"PENN 2015-0212","DECISION_DT":"01/15/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2016-01-15"},{"SOURCE_ROW_NUMBER":"153766","VIOLATION_NO":"7028880","DOCKET_NO":"PENN 2015-0212","DECISION_DT":"01/15/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2744.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2016-01-15"},{"SOURCE_ROW_NUMBER":"152869","VIOLATION_NO":"7019994","DOCKET_NO":"PENN 2015-0212","DECISION_DT":"01/15/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"257.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2016-01-15"},{"SOURCE_ROW_NUMBER":"379964","VIOLATION_NO":"8010743","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"379963","VIOLATION_NO":"8010738","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"379962","VIOLATION_NO":"7020765","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"379805","VIOLATION_NO":"8010736","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"600.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"379804","VIOLATION_NO":"8010691","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"440.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"379803","VIOLATION_NO":"8010682","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"1945.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"379802","VIOLATION_NO":"8010681","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"874.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"379801","VIOLATION_NO":"8010519","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1944.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"},{"SOURCE_ROW_NUMBER":"138485","VIOLATION_NO":"8191247","DOCKET_NO":"PENN 2014-74","DECISION_DT":"12/02/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-12-02"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":2664,"firstDate":"2008-04-22","lastDate":"2019-10-07","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":441,"validSamples":2223,"maxConcentration":7.617,"concentrationTotal":1484.236},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1647728","CASS_NUM":"51460874","SMP_TAKEN_DT":"10/7/2019","CONC":".014","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-10-07"},{"SOURCE_ROW_NUMBER":"1115068","CASS_NUM":"51455957","SMP_TAKEN_DT":"8/2/2019","CONC":".133","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-08-02"},{"SOURCE_ROW_NUMBER":"986334","CASS_NUM":"58374485","SMP_TAKEN_DT":"6/12/2019","CONC":".04","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-06-12"},{"SOURCE_ROW_NUMBER":"597198","CASS_NUM":"51459678","SMP_TAKEN_DT":"4/12/2019","CONC":".286","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-04-12"},{"SOURCE_ROW_NUMBER":"161858","CASS_NUM":"51455907","SMP_TAKEN_DT":"2/5/2019","CONC":".088","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-02-05"},{"SOURCE_ROW_NUMBER":"510123","CASS_NUM":"51459843","SMP_TAKEN_DT":"10/23/2018","CONC":".036","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-10-23"},{"SOURCE_ROW_NUMBER":"39785","CASS_NUM":"51459847","SMP_TAKEN_DT":"7/10/2018","CONC":".09","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-07-10"},{"SOURCE_ROW_NUMBER":"1197277","CASS_NUM":"58305960","SMP_TAKEN_DT":"4/18/2018","CONC":".055","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"1166911","CASS_NUM":"58304865","SMP_TAKEN_DT":"4/18/2018","CONC":".103","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"714391","CASS_NUM":"58306041","SMP_TAKEN_DT":"4/18/2018","CONC":".188","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"466286","CASS_NUM":"58306030","SMP_TAKEN_DT":"4/18/2018","CONC":".019","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"803722","CASS_NUM":"51458626","SMP_TAKEN_DT":"4/10/2018","CONC":".142","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2018-04-10"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":68,"firstDate":"2010-04-01","lastDate":"2015-03-17","metrics":{"linkedIssuances":68},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":256,"firstDate":"2008-05-16","lastDate":"2014-11-25","metrics":{"decisions":256,"ssChanged":81,"recentRows":0,"decisionPenalty":148041,"proposedPenalty":358418},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94079","CITATION_NO":"8006151","CITATION_ISSUE_DT":"11/25/2014","DOCKET_NO":"PENN 2015-0128","DECISION_DT":"07/22/2015","CFR_STANDARD_CODE":"75.380(d)(7)(vi)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"133.00","sourceDate":"2014-11-25"},{"SOURCE_ROW_NUMBER":"376348","CITATION_NO":"7028883","CITATION_ISSUE_DT":"10/02/2014","DOCKET_NO":"PENN 2015-0212","DECISION_DT":"01/15/2016","CFR_STANDARD_CODE":"75.1505(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2014-10-02"},{"SOURCE_ROW_NUMBER":"37088","CITATION_NO":"7028926","CITATION_ISSUE_DT":"09/24/2014","DOCKET_NO":"PENN 2015-0065","DECISION_DT":"07/07/2015","CFR_STANDARD_CODE":"70.100(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"918.00","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"96369","CITATION_NO":"7019994","CITATION_ISSUE_DT":"09/02/2014","DOCKET_NO":"PENN 2015-0212","DECISION_DT":"01/15/2016","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"257.00","sourceDate":"2014-09-02"},{"SOURCE_ROW_NUMBER":"37441","CITATION_NO":"7028880","CITATION_ISSUE_DT":"08/25/2014","DOCKET_NO":"PENN 2015-0212","DECISION_DT":"01/15/2016","CFR_STANDARD_CODE":"48.7(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2744.00","sourceDate":"2014-08-25"},{"SOURCE_ROW_NUMBER":"319286","CITATION_NO":"7029053","CITATION_ISSUE_DT":"06/19/2014","DOCKET_NO":"PENN 2014-0955","DECISION_DT":"08/26/2015","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2014-06-19"},{"SOURCE_ROW_NUMBER":"321514","CITATION_NO":"7029037","CITATION_ISSUE_DT":"04/22/2014","DOCKET_NO":"PENN 2015-0065","DECISION_DT":"07/07/2015","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"150.00","DECISION_PENALTY_AMT":"150.00","sourceDate":"2014-04-22"},{"SOURCE_ROW_NUMBER":"204022","CITATION_NO":"8001425","CITATION_ISSUE_DT":"02/26/2014","DOCKET_NO":"PENN 2014-0967","DECISION_DT":"08/26/2015","CFR_STANDARD_CODE":"77.1607(bb)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"557.00","sourceDate":"2014-02-26"},{"SOURCE_ROW_NUMBER":"33755","CITATION_NO":"8000821","CITATION_ISSUE_DT":"02/26/2014","DOCKET_NO":"PENN 2014-0967","DECISION_DT":"08/26/2015","CFR_STANDARD_CODE":"75.1107-16(a)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":".00","sourceDate":"2014-02-26"},{"SOURCE_ROW_NUMBER":"431182","CITATION_NO":"7028729","CITATION_ISSUE_DT":"02/25/2014","DOCKET_NO":"PENN 2014-0967","DECISION_DT":"08/26/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1682.00","sourceDate":"2014-02-25"},{"SOURCE_ROW_NUMBER":"430646","CITATION_NO":"7028728","CITATION_ISSUE_DT":"02/25/2014","DOCKET_NO":"PENN 2014-0967","DECISION_DT":"08/26/2015","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"280.00","sourceDate":"2014-02-25"},{"SOURCE_ROW_NUMBER":"203083","CITATION_NO":"7028730","CITATION_ISSUE_DT":"02/25/2014","DOCKET_NO":"PENN 2014-0967","DECISION_DT":"08/26/2015","CFR_STANDARD_CODE":"75.360(b)(11)(iii)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"980.00","sourceDate":"2014-02-25"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":505,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":114,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2007-08-15","lastDate":"2007-08-15","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":99,"firstDate":"2008-02-21","lastDate":"2020-09-02","metrics":{"inspectors":317,"recentRows":0,"onSiteHours":11479.25,"inspectionHours":17963.5,"inspectionSamples":2406},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"525602","EVENT_NO":"6237233","INSPECTION_BEGIN_DT":"09/02/2020","INSPECTION_END_DT":"09/10/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2020-09-02"},{"SOURCE_ROW_NUMBER":"1033340","EVENT_NO":"6237044","INSPECTION_BEGIN_DT":"02/14/2020","INSPECTION_END_DT":"02/14/2020","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2020-02-14"},{"SOURCE_ROW_NUMBER":"833571","EVENT_NO":"6218306","INSPECTION_BEGIN_DT":"06/11/2019","INSPECTION_END_DT":"06/19/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.25","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2019-06-11"},{"SOURCE_ROW_NUMBER":"365071","EVENT_NO":"6218301","INSPECTION_BEGIN_DT":"03/18/2019","INSPECTION_END_DT":"03/19/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"28","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2019-03-18"},{"SOURCE_ROW_NUMBER":"896793","EVENT_NO":"6227143","INSPECTION_BEGIN_DT":"04/16/2018","INSPECTION_END_DT":"04/18/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2018-04-16"},{"SOURCE_ROW_NUMBER":"884954","EVENT_NO":"6236492","INSPECTION_BEGIN_DT":"12/04/2017","INSPECTION_END_DT":"12/27/2017","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2017-12-04"},{"SOURCE_ROW_NUMBER":"339677","EVENT_NO":"6236574","INSPECTION_BEGIN_DT":"11/27/2017","INSPECTION_END_DT":"12/14/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"10.25","sourceDate":"2017-11-27"},{"SOURCE_ROW_NUMBER":"739489","EVENT_NO":"6236448","INSPECTION_BEGIN_DT":"08/16/2017","INSPECTION_END_DT":"09/05/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2017-08-16"},{"SOURCE_ROW_NUMBER":"666999","EVENT_NO":"6236386","INSPECTION_BEGIN_DT":"03/30/2017","INSPECTION_END_DT":"03/30/2017","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.25","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2017-03-30"},{"SOURCE_ROW_NUMBER":"738306","EVENT_NO":"6236238","INSPECTION_BEGIN_DT":"02/16/2017","INSPECTION_END_DT":"03/15/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"28.5","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2017-02-16"},{"SOURCE_ROW_NUMBER":"406050","EVENT_NO":"6236041","INSPECTION_BEGIN_DT":"12/09/2016","INSPECTION_END_DT":"01/10/2017","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2016-12-09"},{"SOURCE_ROW_NUMBER":"301348","EVENT_NO":"4035824","INSPECTION_BEGIN_DT":"05/31/2016","INSPECTION_END_DT":"06/06/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"11.75","sourceDate":"2016-05-31"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":27,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010":{"hours":328138,"employees":149,"production":580713},"2011":{"hours":360895,"employees":172,"production":736348},"2012":{"hours":432561,"employees":196,"production":769923},"2013":{"hours":449496,"employees":205,"production":652325},"2014":{"hours":337433,"employees":161,"production":406037},"2015":{"hours":19301,"employees":24,"production":0},"2016":{"hours":1068,"employees":1,"production":0},"2017":{"hours":2938,"employees":2,"production":0},"2018":{"hours":5767,"employees":2,"production":0},"2019":{"hours":7250,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":266,"firstDate":"2008-06-11","lastDate":"2019-06-12","metrics":{"recentRows":0,"doseOver100":65,"actDoseTotal":19755,"pelDoseTotal":14970},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"175204","EVENT_NO":"6218306","SURVEY_DATE":"06/12/2019","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"61","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2019-06-12"},{"SOURCE_ROW_NUMBER":"175208","EVENT_NO":"6227143","SURVEY_DATE":"04/18/2018","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"48","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"175207","EVENT_NO":"6227143","SURVEY_DATE":"04/18/2018","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"29","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"175206","EVENT_NO":"6227143","SURVEY_DATE":"04/18/2018","OCCUPATION_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"063","ACT_DOSE_85":"12","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"175205","EVENT_NO":"6227143","SURVEY_DATE":"04/18/2018","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"28","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2018-04-18"},{"SOURCE_ROW_NUMBER":"175213","EVENT_NO":"6236574","SURVEY_DATE":"12/05/2017","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"86","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2017-12-05"},{"SOURCE_ROW_NUMBER":"175212","EVENT_NO":"6236238","SURVEY_DATE":"03/01/2017","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"25","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"175211","EVENT_NO":"6236238","SURVEY_DATE":"03/01/2017","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"063","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"175210","EVENT_NO":"6236238","SURVEY_DATE":"03/01/2017","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"12","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"175209","EVENT_NO":"6236238","SURVEY_DATE":"03/01/2017","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"95","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"174984","EVENT_NO":"4031870","SURVEY_DATE":"11/05/2014","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"019","ACT_DOSE_85":"36","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"174983","EVENT_NO":"4031870","SURVEY_DATE":"10/20/2014","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"49","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2014-10-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":196,"firstDate":"2008-06-12","lastDate":"2017-03-01","metrics":{"recentRows":0,"voidSamples":13,"maxQuartzPct":27.5,"validSamples":183,"quartzPctTotal":1219.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"9213","CASSETTE_NO":"58307777","SAMPLE_DT":"03/01/2017","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"116688","CASSETTE_NO":"58144986","SAMPLE_DT":"11/13/2014","QUARTZ_PCT":"00.9","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"85720","CASSETTE_NO":"58144752","SAMPLE_DT":"11/13/2014","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-13"},{"SOURCE_ROW_NUMBER":"132824","CASSETTE_NO":"58145142","SAMPLE_DT":"11/10/2014","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-10"},{"SOURCE_ROW_NUMBER":"34358","CASSETTE_NO":"58144824","SAMPLE_DT":"11/05/2014","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"UTILITY MAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"15681","CASSETTE_NO":"58142544","SAMPLE_DT":"09/15/2014","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"64","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INVALID PRODUCTION","sourceDate":"2014-09-15"},{"SOURCE_ROW_NUMBER":"124677","CASSETTE_NO":"58142461","SAMPLE_DT":"09/04/2014","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-09-04"},{"SOURCE_ROW_NUMBER":"103227","CASSETTE_NO":"58142473","SAMPLE_DT":"09/04/2014","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-09-04"},{"SOURCE_ROW_NUMBER":"149096","CASSETTE_NO":"58142573","SAMPLE_DT":"08/13/2014","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-08-13"},{"SOURCE_ROW_NUMBER":"76196","CASSETTE_NO":"58142438","SAMPLE_DT":"08/13/2014","QUARTZ_PCT":"00.5","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-08-13"},{"SOURCE_ROW_NUMBER":"36529","CASSETTE_NO":"58146632","SAMPLE_DT":"05/20/2014","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-05-20"},{"SOURCE_ROW_NUMBER":"75474","CASSETTE_NO":"58146577","SAMPLE_DT":"05/13/2014","QUARTZ_PCT":"01.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-05-13"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1024,"firstDate":"2008-04-15","lastDate":"2019-03-18","metrics":{"ss":173,"amountDue":317185,"contested":166,"amountPaid":317185,"recentRows":0,"section104d":3,"unterminated":0,"proposedPenalty":483564},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1991531","VIOLATION_NO":"9200016","VIOLATION_ISSUE_DT":"03/18/2019","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/18/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-03-18"},{"SOURCE_ROW_NUMBER":"1991530","VIOLATION_NO":"9200015","VIOLATION_ISSUE_DT":"03/18/2019","SIG_SUB":"N","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/18/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-03-18"},{"SOURCE_ROW_NUMBER":"1992026","VIOLATION_NO":"9077797","VIOLATION_ISSUE_DT":"08/17/2017","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/17/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"116","CONTESTED_IND":"N","sourceDate":"2017-08-17"},{"SOURCE_ROW_NUMBER":"1991527","VIOLATION_NO":"9071558","VIOLATION_ISSUE_DT":"03/01/2017","SIG_SUB":"N","PART_SECTION":"77.1713(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/01/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"116","CONTESTED_IND":"N","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"1991526","VIOLATION_NO":"9071557","VIOLATION_ISSUE_DT":"03/01/2017","SIG_SUB":"N","PART_SECTION":"77.1109(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/01/2017","PROPOSED_PENALTY":"259","AMOUNT_DUE":"259","AMOUNT_PAID":"259","CONTESTED_IND":"N","sourceDate":"2017-03-01"},{"SOURCE_ROW_NUMBER":"1991732","VIOLATION_NO":"7032742","VIOLATION_ISSUE_DT":"04/27/2015","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/27/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-04-27"},{"SOURCE_ROW_NUMBER":"1991731","VIOLATION_NO":"7032741","VIOLATION_ISSUE_DT":"04/23/2015","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/27/2015","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2015-04-23"},{"SOURCE_ROW_NUMBER":"1991730","VIOLATION_NO":"7032737","VIOLATION_ISSUE_DT":"04/09/2015","SIG_SUB":"N","PART_SECTION":"75.1502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/09/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-04-09"},{"SOURCE_ROW_NUMBER":"1991515","VIOLATION_NO":"8006153","VIOLATION_ISSUE_DT":"01/06/2015","SIG_SUB":"N","PART_SECTION":"75.364(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-01-06"},{"SOURCE_ROW_NUMBER":"1991514","VIOLATION_NO":"8006152","VIOLATION_ISSUE_DT":"01/06/2015","SIG_SUB":"N","PART_SECTION":"75.364(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-01-06"},{"SOURCE_ROW_NUMBER":"1992091","VIOLATION_NO":"8006151","VIOLATION_ISSUE_DT":"11/25/2014","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(vi)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/25/2014","PROPOSED_PENALTY":"190","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2014-11-25"},{"SOURCE_ROW_NUMBER":"1992090","VIOLATION_NO":"7028900","VIOLATION_ISSUE_DT":"11/24/2014","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/24/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-11-24"}]}],"safety":{"href":"/api/v1/mines/3609549/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609549/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1713","heading":"Daily inspection of surface coal mine; certified person; reports of inspection.","id":"77.1713","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1713","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) At least once during each working shift, or more often if necessary for safety, each active working area and each active surface installation shall be examined by a certified person designated by the operator to conduct such examinations for hazardous conditions and any hazardous conditions noted during such examinations shall be reported to the operator and shall be corrected by the operator.\n\n(b) If any hazardous condition noted during an examination conducted in accordance with paragraph (a) of this section creates an imminent danger, the person conducting such examination shall notify the operator and the operator shall withdraw all persons from the area affected, except those persons referred to in section 104(d) of the Act, until the danger is abated.\n\n(c) After each examination conducted in accordance with the provisions of paragraph (a) of this section, each certified person who conducted all or any part of the examination required shall enter with ink or indelible pencil in a book approved by the Secretary the date and a report of the condition of the mine or any area of the mine which he has inspected together with a report of the nature and location of any hazardous condition found to be present at the mine. The book in which such entries are made shall be kept in an area at the mine designated by the operator to minimize the danger of destruction by fire or other hazard.\n\n(d) All examination reports recorded in accordance with the provisions of paragraph (c) of this section shall include a report of the action taken to abate hazardous conditions and shall be signed or countersigned each day by at least one of the following persons:\n\n(1) The surface mine foreman;\n\n(2) The assistant superintendent of the mine;\n\n(3) The superintendent of the mine;\n\n(4) The person designated by the operator as responsible for health and safety at the mine; or,\n\n(5) An equivalent mine official.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995; 63 FR 58613, Oct. 30, 1998]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Mine emergency evacuation and firefighting program of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1502","part":"75","subchapter":"O","subpart":"P","id":"75.1502","citation":"30 CFR 75.1502","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609549","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}