{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3609435","name":"Williamstown Mine #1","status":"Active","status_date":"2020-12-22","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Anthracite)","state":"PA","county":"Dauphin","nearest_town":"Williamstown","operator_id":"0073786","operator_name":"Kimmel's Mining, Inc","controller_id":"0040883","controller_name":"Scott B  Kimmel","district":"M2","office":"Frackville PA Field Office","employees":6,"latitude":40.594722,"longitude":-76.586667},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":1746},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609435","name":"Williamstown Mine #1"},"operator":{"type":"operator","id":"0073786","name":"Kimmel's Mining, Inc"},"controller":{"type":"controller","id":"0040883","name":"Scott B  Kimmel"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0073786","name":"Kimmel's Mining, Inc"},"object":{"type":"mine","id":"3609435","name":"Williamstown Mine #1"},"validFrom":"2006-07-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609435|0073786|2006-07-18|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0040883","name":"Scott B  Kimmel"},"object":{"type":"mine","id":"3609435","name":"Williamstown Mine #1"},"validFrom":"2006-07-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609435|0040883|2006-07-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0040883","name":"Scott B  Kimmel"},"object":{"type":"operator","id":"0073786","name":"Kimmel's Mining, Inc"},"validFrom":"2006-07-18","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609435","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609435|0073786|2006-07-18|0040883|2006-07-18|900"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2008-08-18","lastDate":"2020-10-27","metrics":{"daysLost":159,"injuries":3,"fatalities":1,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"93027","DOCUMENT_NO":"220203080009","ACCIDENT_DT":"10/27/2020","DEGREE_INJURY":"FATALITY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"Feather edge false roof fall resulting in a death","sourceDate":"2020-10-27"},{"SOURCE_ROW_NUMBER":"50122","DOCUMENT_NO":"220082540035","ACCIDENT_DT":"08/21/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner helper, Coal mole helper, Bridgeman","NO_INJURIES":"1","DAYS_LOST":"109","NARRATIVE":"In entrance #3 (beltline) the conditions were wet and sloppy, no bottom had been cut and the floor was slick. EE slipped and twisted right knee resulting in torn mcl and miner cartilage damage.","sourceDate":"2008-08-21"},{"SOURCE_ROW_NUMBER":"217929","DOCUMENT_NO":"220082330034","ACCIDENT_DT":"08/18/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"50","NARRATIVE":"Area was about 38' high causing use of different drill steels.","sourceDate":"2008-08-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-12-22","lastDate":"2020-12-22","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":106,"firstDate":"2006-09-15","lastDate":"2026-07-27","metrics":{"ss":14,"delinquent":95,"recentRows":27,"paidPenalty":14051,"proposedPenalty":14957,"currentAssessment":14957},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3015813","VIOLATION_NO":"5154681","ISSUE_DT":"07/27/2026","CFR_STANDARD_CD":"70.208(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"3013711","VIOLATION_NO":"9606437","ISSUE_DT":"07/13/2026","CFR_STANDARD_CD":"75.333(c)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"3013710","VIOLATION_NO":"9606436","ISSUE_DT":"07/07/2026","CFR_STANDARD_CD":"77.1109(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-07-07"},{"SOURCE_ROW_NUMBER":"2988100","VIOLATION_NO":"5155802","ISSUE_DT":"05/14/2026","CFR_STANDARD_CD":"47.41(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-05-14"},{"SOURCE_ROW_NUMBER":"3013702","VIOLATION_NO":"9606428","ISSUE_DT":"05/06/2026","CFR_STANDARD_CD":"75.381(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2026-05-06"},{"SOURCE_ROW_NUMBER":"2988061","VIOLATION_NO":"9606326","ISSUE_DT":"01/28/2026","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-01-28"},{"SOURCE_ROW_NUMBER":"2984900","VIOLATION_NO":"9606317","ISSUE_DT":"10/07/2025","CFR_STANDARD_CD":"75.1505(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2025-10-07"},{"SOURCE_ROW_NUMBER":"2973155","VIOLATION_NO":"9603950","ISSUE_DT":"07/07/2025","CFR_STANDARD_CD":"75.381(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-07-07"},{"SOURCE_ROW_NUMBER":"2973145","VIOLATION_NO":"9603940","ISSUE_DT":"04/07/2025","CFR_STANDARD_CD":"75.1100-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-04-07"},{"SOURCE_ROW_NUMBER":"2930313","VIOLATION_NO":"9603929","ISSUE_DT":"01/14/2025","CFR_STANDARD_CD":"75.520","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"226.00","CURRENT_ASSESSMENT_AMT":"226.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-01-14"},{"SOURCE_ROW_NUMBER":"2930305","VIOLATION_NO":"9209807","ISSUE_DT":"10/09/2024","CFR_STANDARD_CD":"75.1714-8(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-10-09"},{"SOURCE_ROW_NUMBER":"2930282","VIOLATION_NO":"9209774","ISSUE_DT":"07/29/2024","CFR_STANDARD_CD":"75.206(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-07-29"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1097,"firstDate":"2007-06-07","lastDate":"2054-10-05","metrics":{"recentRows":462,"cpdmSamples":0,"voidSamples":106,"validSamples":991,"maxConcentration":6.702,"concentrationTotal":189.529},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"506224","CASS_NUM":"51464284","SMP_TAKEN_DT":"10/5/2054","CONC":".105","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2054-10-05"},{"SOURCE_ROW_NUMBER":"450817","CASS_NUM":"51671591","SMP_TAKEN_DT":"8/4/2026","CONC":".014","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"1011767","CASS_NUM":"51671584","SMP_TAKEN_DT":"8/3/2026","CONC":".009","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-03"},{"SOURCE_ROW_NUMBER":"433449","CASS_NUM":"51671582","SMP_TAKEN_DT":"7/31/2026","CONC":".006","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-31"},{"SOURCE_ROW_NUMBER":"537194","CASS_NUM":"51671587","SMP_TAKEN_DT":"7/30/2026","CONC":".013","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-30"},{"SOURCE_ROW_NUMBER":"563093","CASS_NUM":"51671588","SMP_TAKEN_DT":"7/29/2026","CONC":".011","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"72528","CASS_NUM":"51671576","SMP_TAKEN_DT":"7/28/2026","CONC":".003","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"482961","CASS_NUM":"51671581","SMP_TAKEN_DT":"7/27/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"425582","CASS_NUM":"51671625","SMP_TAKEN_DT":"7/24/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-24"},{"SOURCE_ROW_NUMBER":"153735","CASS_NUM":"51671631","SMP_TAKEN_DT":"7/23/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"380651","CASS_NUM":"51671627","SMP_TAKEN_DT":"7/22/2026","CONC":".006","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-22"},{"SOURCE_ROW_NUMBER":"875275","CASS_NUM":"51671634","SMP_TAKEN_DT":"7/21/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-21"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2006-10-25","lastDate":"2022-11-14","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2006-07-18","lastDate":"2006-07-18","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":181,"firstDate":"2006-09-14","lastDate":"2026-10-07","metrics":{"inspectors":253,"recentRows":62,"onSiteHours":4150.75,"inspectionHours":6675.25,"inspectionSamples":530},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"820622","EVENT_NO":"F04E18B","INSPECTION_BEGIN_DT":"10/07/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"592756","EVENT_NO":"F04349C","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"226512","EVENT_NO":"F043498","INSPECTION_BEGIN_DT":"09/15/2026","INSPECTION_END_DT":"09/22/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18.25","SUM_TOTAL_ON_SITE_HOURS":"15","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"354139","EVENT_NO":"F02B117","INSPECTION_BEGIN_DT":"07/27/2026","INSPECTION_END_DT":"07/27/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"900167","EVENT_NO":"F02A012","INSPECTION_BEGIN_DT":"07/06/2026","INSPECTION_END_DT":"07/14/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2026-07-06"},{"SOURCE_ROW_NUMBER":"335126","EVENT_NO":"F02A011","INSPECTION_BEGIN_DT":"07/06/2026","INSPECTION_END_DT":"07/14/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"35.5","SUM_TOTAL_ON_SITE_HOURS":"30.5","sourceDate":"2026-07-06"},{"SOURCE_ROW_NUMBER":"1055714","EVENT_NO":"4309956","INSPECTION_BEGIN_DT":"06/24/2026","INSPECTION_END_DT":"06/24/2026","ACTIVITY_CODE":"E24","ACTIVITY":"Other Technical Compliance Investigations","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"714372","EVENT_NO":"F02A010","INSPECTION_BEGIN_DT":"06/15/2026","INSPECTION_END_DT":"06/30/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2026-06-15"},{"SOURCE_ROW_NUMBER":"791634","EVENT_NO":"F019B2B","INSPECTION_BEGIN_DT":"05/11/2026","INSPECTION_END_DT":"05/14/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"40","SUM_TOTAL_ON_SITE_HOURS":"26","sourceDate":"2026-05-11"},{"SOURCE_ROW_NUMBER":"626265","EVENT_NO":"F02A000","INSPECTION_BEGIN_DT":"03/23/2026","INSPECTION_END_DT":"05/28/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"38.5","SUM_TOTAL_ON_SITE_HOURS":"21.5","sourceDate":"2026-03-23"},{"SOURCE_ROW_NUMBER":"615970","EVENT_NO":"F029FF7","INSPECTION_BEGIN_DT":"02/17/2026","INSPECTION_END_DT":"03/18/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2026-02-17"},{"SOURCE_ROW_NUMBER":"614849","EVENT_NO":"F029FF4","INSPECTION_BEGIN_DT":"02/10/2026","INSPECTION_END_DT":"02/19/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20.5","SUM_TOTAL_ON_SITE_HOURS":"12.25","sourceDate":"2026-02-10"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":121,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":4320,"employees":9,"production":2827},"2026-Q1":{"hours":4320,"employees":9,"production":0},"2025-Q4":{"hours":4320,"employees":9,"production":2278},"2025-Q3":{"hours":4800,"employees":9,"production":0},"2025-Q2":{"hours":4320,"employees":9,"production":3482},"2025-Q1":{"hours":3840,"employees":8,"production":3066},"2024-Q4":{"hours":3840,"employees":8,"production":2244},"2024-Q3":{"hours":4240,"employees":8,"production":2746},"2024-Q2":{"hours":3840,"employees":8,"production":2299},"2024-Q1":{"hours":3360,"employees":7,"production":2735},"2023-Q4":{"hours":2880,"employees":6,"production":1904},"2023-Q3":{"hours":3360,"employees":6,"production":2076}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":31,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":17160,"employees":8,"production":13475},"2018":{"hours":15600,"employees":8,"production":13216},"2019":{"hours":18720,"employees":9,"production":8011},"2020":{"hours":15880,"employees":8,"production":10195},"2021":{"hours":12960,"employees":7,"production":9056},"2022":{"hours":14240,"employees":7,"production":9009},"2023":{"hours":9120,"employees":6,"production":5661},"2024":{"hours":15280,"employees":8,"production":10024},"2025":{"hours":17280,"employees":9,"production":8826},"2026":{"hours":8640,"employees":9,"production":2827}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":78,"firstDate":"2008-02-20","lastDate":"2026-05-13","metrics":{"recentRows":25,"doseOver100":10,"actDoseTotal":3563,"pelDoseTotal":2539},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"173288","EVENT_NO":"F019B2B","SURVEY_DATE":"05/13/2026","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"49","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2026-05-13"},{"SOURCE_ROW_NUMBER":"173287","EVENT_NO":"F019B1D","SURVEY_DATE":"02/19/2026","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"40","ACT_DOSE_85":"5","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-02-19"},{"SOURCE_ROW_NUMBER":"173286","EVENT_NO":"F019B1D","SURVEY_DATE":"02/19/2026","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"19","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2026-02-19"},{"SOURCE_ROW_NUMBER":"173285","EVENT_NO":"F018176","SURVEY_DATE":"11/12/2025","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"19","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2025-11-12"},{"SOURCE_ROW_NUMBER":"173284","EVENT_NO":"F018176","SURVEY_DATE":"10/06/2025","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"20","ACT_DOSE_85":"23","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2025-10-06"},{"SOURCE_ROW_NUMBER":"173283","EVENT_NO":"F018176","SURVEY_DATE":"10/06/2025","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"25","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2025-10-06"},{"SOURCE_ROW_NUMBER":"173282","EVENT_NO":"F009C75","SURVEY_DATE":"10/28/2024","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"31","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2024-10-28"},{"SOURCE_ROW_NUMBER":"173281","EVENT_NO":"F009C75","SURVEY_DATE":"10/09/2024","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","ACT_DOSE_85":"18","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2024-10-09"},{"SOURCE_ROW_NUMBER":"173280","EVENT_NO":"F009C75","SURVEY_DATE":"10/09/2024","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"20","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2024-10-09"},{"SOURCE_ROW_NUMBER":"173279","EVENT_NO":"4315027","SURVEY_DATE":"04/29/2024","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"32","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2024-04-29"},{"SOURCE_ROW_NUMBER":"173278","EVENT_NO":"4315016","SURVEY_DATE":"02/12/2024","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"30","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2024-02-12"},{"SOURCE_ROW_NUMBER":"173277","EVENT_NO":"4314700","SURVEY_DATE":"10/25/2023","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","ACT_DOSE_85":"27","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2023-10-25"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":12,"firstDate":"2008-05-05","lastDate":"2025-04-07","metrics":{"recentRows":4,"voidSamples":0,"maxQuartzPct":8.8,"validSamples":12,"quartzPctTotal":44.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"95731","CASSETTE_NO":"58558372","SAMPLE_DT":"04/07/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-04-07"},{"SOURCE_ROW_NUMBER":"35903","CASSETTE_NO":"58490105","SAMPLE_DT":"04/24/2023","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-04-24"},{"SOURCE_ROW_NUMBER":"34265","CASSETTE_NO":"58478688","SAMPLE_DT":"01/23/2023","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-01-23"},{"SOURCE_ROW_NUMBER":"167455","CASSETTE_NO":"58454625","SAMPLE_DT":"04/26/2022","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2022-04-26"},{"SOURCE_ROW_NUMBER":"122149","CASSETTE_NO":"58360670","SAMPLE_DT":"11/12/2019","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-11-12"},{"SOURCE_ROW_NUMBER":"37357","CASSETTE_NO":"58344353","SAMPLE_DT":"01/22/2019","QUARTZ_PCT":"02.1","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-01-22"},{"SOURCE_ROW_NUMBER":"113265","CASSETTE_NO":"58198897","SAMPLE_DT":"10/21/2015","QUARTZ_PCT":"00.5","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-10-21"},{"SOURCE_ROW_NUMBER":"68087","CASSETTE_NO":"57721009","SAMPLE_DT":"08/20/2008","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-08-20"},{"SOURCE_ROW_NUMBER":"51176","CASSETTE_NO":"57721013","SAMPLE_DT":"08/20/2008","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-08-20"},{"SOURCE_ROW_NUMBER":"24797","CASSETTE_NO":"57721011","SAMPLE_DT":"08/20/2008","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-08-20"},{"SOURCE_ROW_NUMBER":"44098","CASSETTE_NO":"57721124","SAMPLE_DT":"07/23/2008","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-07-23"},{"SOURCE_ROW_NUMBER":"64861","CASSETTE_NO":"57676006","SAMPLE_DT":"05/05/2008","QUARTZ_PCT":"08.8","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-05-05"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":112,"firstDate":"2006-09-15","lastDate":"2026-10-05","metrics":{"ss":14,"amountDue":14957,"contested":0,"amountPaid":14051,"recentRows":29,"section104d":0,"unterminated":1,"proposedPenalty":14957},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1986951","VIOLATION_NO":"9606449","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.333(c)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"5","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"1986940","VIOLATION_NO":"5154681","VIOLATION_ISSUE_DT":"07/27/2026","SIG_SUB":"N","PART_SECTION":"70.208(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1986922","VIOLATION_NO":"9606437","VIOLATION_ISSUE_DT":"07/13/2026","SIG_SUB":"N","PART_SECTION":"75.333(c)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"5","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/13/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"1986921","VIOLATION_NO":"9606436","VIOLATION_ISSUE_DT":"07/07/2026","SIG_SUB":"N","PART_SECTION":"77.1109(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/07/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-07"},{"SOURCE_ROW_NUMBER":"1986912","VIOLATION_NO":"5155802","VIOLATION_ISSUE_DT":"05/14/2026","SIG_SUB":"N","PART_SECTION":"47.41(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/14/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-05-14"},{"SOURCE_ROW_NUMBER":"1986876","VIOLATION_NO":"9606428","VIOLATION_ISSUE_DT":"05/06/2026","SIG_SUB":"N","PART_SECTION":"75.381(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/06/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-05-06"},{"SOURCE_ROW_NUMBER":"1986869","VIOLATION_NO":"9606326","VIOLATION_ISSUE_DT":"01/28/2026","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/28/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-01-28"},{"SOURCE_ROW_NUMBER":"1986955","VIOLATION_NO":"9606317","VIOLATION_ISSUE_DT":"10/07/2025","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/07/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2025-10-07"},{"SOURCE_ROW_NUMBER":"1986916","VIOLATION_NO":"9603950","VIOLATION_ISSUE_DT":"07/07/2025","SIG_SUB":"N","PART_SECTION":"75.381(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/07/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-07-07"},{"SOURCE_ROW_NUMBER":"1986879","VIOLATION_NO":"9603940","VIOLATION_ISSUE_DT":"04/07/2025","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/07/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-04-07"},{"SOURCE_ROW_NUMBER":"1986866","VIOLATION_NO":"9603929","VIOLATION_ISSUE_DT":"01/14/2025","SIG_SUB":"Y","PART_SECTION":"75.520","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/14/2025","PROPOSED_PENALTY":"226","AMOUNT_DUE":"226","AMOUNT_PAID":"226","CONTESTED_IND":"N","sourceDate":"2025-01-14"},{"SOURCE_ROW_NUMBER":"1986956","VIOLATION_NO":"9209807","VIOLATION_ISSUE_DT":"10/09/2024","SIG_SUB":"N","PART_SECTION":"75.1714-8(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/21/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-10-09"}]}],"safety":{"href":"/api/v1/mines/3609435/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609435/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":8,"companyType":"Independent Producer Operator","components":[{"averageEmployees":8,"laborHours":15280,"mineType":"Underground","productionTons":10024}],"county":"Dauphin","laborHours":15280,"mineName":"Williamstown Mine #1","mineType":"Underground","mshaId":"3609435","operatingAddress":"17rr East Grand Avenue, Tower City, PA 17980","operatingCompany":"Kimmel's Mining, Inc","operationType":"Mine only","productionTons":10024,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Pennsylvania (Anthracite)","status":"Active","supplyRegion":"Appalachia Northern","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":2},{"chapter":"I","heading":"Quarterly sampling; mechanized mining units.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.208","part":"70","subchapter":"O","subpart":"C","id":"70.208","citation":"30 CFR 70.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 47.41","heading":"Requirement for container labels.","id":"47.41","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-47/subpart-E/section-47.41","part":"47","partHeading":"PART 47—HAZARD COMMUNICATION (HazCom)","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"E","subpartHeading":"Subpart E—Container Labels and Other Forms of Warning","text":"(a) The operator must ensure that each container of a hazardous chemical has a label. If a container is tagged or marked with the appropriate information, it is labeled.\n\n(1) The operator must replace a container label immediately if it is missing or if the hazard information on the label is unreadable.\n\n(2) The operator must not remove or deface existing labels on containers of hazardous chemicals.\n\n(b) For each hazardous chemical produced at the mine, the operator must prepare a container label and update this label with any significant, new information about the chemical's hazards within 3 months of becoming aware of this information.\n\n(c) For each hazardous chemical brought to the mine, the operator must replace an outdated label when a revised label is received from the chemical's manufacturer or supplier. The operator is not responsible for an inaccurate label obtained from the chemical's manufacturer or supplier.","occurrenceCount":1},{"chapter":"I","heading":"Escapeways; anthracite mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.381","part":"75","subchapter":"O","subpart":"D","id":"75.381","citation":"30 CFR 75.381","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; switches.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.520","part":"75","subchapter":"O","subpart":"F","id":"75.520","citation":"30 CFR 75.520","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Reporting SCSR inventory and malfunctions; retention of SCSRs.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-8","part":"75","subchapter":"O","subpart":"R","id":"75.1714-8","citation":"30 CFR 75.1714-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609435","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}