{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3609401","name":"Primrose Operation","status":"Active","status_date":"2017-05-11","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Anthracite)","state":"PA","county":"Schuylkill","nearest_town":"Mahanoy City","operator_id":"P21041","operator_name":"Blaschak Anthracite Corporation","controller_id":"C09456","controller_name":"Blaschak Holding Corp","district":"M2","office":"Frackville PA Field Office","employees":19,"latitude":40.828056,"longitude":-76.115278},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1784},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609401","name":"Primrose Operation"},"operator":{"type":"operator","id":"P21041","name":"Blaschak Anthracite Corporation"},"controller":{"type":"controller","id":"C09456","name":"Blaschak Holding Corp"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C09456","name":"Blaschak Holding Corp"},"object":{"type":"mine","id":"3609401","name":"Primrose Operation"},"validFrom":"1981-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609401|C09456|1981-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21041","name":"Blaschak Anthracite Corporation"},"object":{"type":"mine","id":"3609401","name":"Primrose Operation"},"validFrom":"2006-03-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609401|P21041|2006-03-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C09456","name":"Blaschak Holding Corp"},"object":{"type":"operator","id":"P21041","name":"Blaschak Anthracite Corporation"},"validFrom":"2006-03-22","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609401","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609401|P21041|2006-03-22|C09456|1981-11-01|79698"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":37,"firstDate":"2007-08-28","lastDate":"2024-02-20","metrics":{"daysLost":1708,"injuries":37,"fatalities":0,"recentRows":7,"restrictedDays":50,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"54373","DOCUMENT_NO":"220240590013","ACCIDENT_DT":"02/20/2024","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"When walking down dragline, dust blew into eye causing irritation.","sourceDate":"2024-02-20"},{"SOURCE_ROW_NUMBER":"209256","DOCUMENT_NO":"220240320020","ACCIDENT_DT":"01/31/2024","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Flash burns (welding)","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was helping the welders all day long. Employee texted their foreman at 10 PM at night to inform them that their eyes are hurting and EE was going to the emergency room. It was found that EE had suffered welders flash. EE had both been around welding all day and lowered the shade setting on their helmet from 11 to 9, which is below the recommended setting.","sourceDate":"2024-01-31"},{"SOURCE_ROW_NUMBER":"213622","DOCUMENT_NO":"220232830067","ACCIDENT_DT":"09/01/2023","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"While pushing a large rock alone with one other D10 dozer, the rock overturned catching the bottom lip of the blade. This lifted the dozer 1-2 feet in the front and then fell down. The bounce caused EE to hit head off the cab. EE did not seek medical treatment until 10/04/2023.","sourceDate":"2023-09-01"},{"SOURCE_ROW_NUMBER":"217927","DOCUMENT_NO":"220231170005","ACCIDENT_DT":"04/19/2023","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was lifting a ladder to support PCR on dragline.","sourceDate":"2023-04-19"},{"SOURCE_ROW_NUMBER":"97271","DOCUMENT_NO":"220223210001","ACCIDENT_DT":"11/08/2022","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Rotary bucket excavator operator","NO_INJURIES":"1","DAYS_LOST":"83","NARRATIVE":"Foot slipped off the catwalk on excavator and went between the catwalk and the step. Employee's foot was caught and EE fell down off excavator, breaking EE's leg due to foot being stuck. EE then fell to the ground. Broke lower right leg.","sourceDate":"2022-11-08"},{"SOURCE_ROW_NUMBER":"248042","DOCUMENT_NO":"220222420006","ACCIDENT_DT":"08/22/2022","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee was removing a piece of drag rope from inside the shovel of the 7450 dragline. While moving it over EE walking shaft, EE lost control of the drag rope and it struck EE in the arm causing a contusion in left upper arm.","sourceDate":"2022-08-22"},{"SOURCE_ROW_NUMBER":"110136","DOCUMENT_NO":"220212950017","ACCIDENT_DT":"10/14/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"171","NARRATIVE":"Employee backed over a rock while operating dozer. No equipment damage. Employee claims they bounced and received a contusion on their shoulder.","sourceDate":"2021-10-14"},{"SOURCE_ROW_NUMBER":"54372","DOCUMENT_NO":"220202870016","ACCIDENT_DT":"08/18/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Welder (non-shop)","NO_INJURIES":"1","DAYS_LOST":"74","NARRATIVE":"Employee was on floor welding plug hole for plates in 777 haul truck box, employee needed more lead so they crawled to suitcase welder, grabbed it with right hand and gave it a yank.","sourceDate":"2020-08-18"},{"SOURCE_ROW_NUMBER":"114514","DOCUMENT_NO":"220201070004","ACCIDENT_DT":"04/14/2020","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"23","NARRATIVE":"When lowering a pump into the pit, the excess hose likely slid down over the highwall and snapped the portion of the hose laying on the bench tight, which caused the portion hanging over the edge to jump over some rocks that stuck out from the highwall and straighten out across the bench, snapping the hose back towards the pickup and striking employee in the leg.","sourceDate":"2020-04-14"},{"SOURCE_ROW_NUMBER":"15735","DOCUMENT_NO":"220183310006","ACCIDENT_DT":"11/16/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was removing snow from the patrol pick up truck and suffered a slip when stepping on the running board.","sourceDate":"2018-11-16"},{"SOURCE_ROW_NUMBER":"11469","DOCUMENT_NO":"220182560028","ACCIDENT_DT":"09/06/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"Stepped out of truck, stepping on uneven ground (rut/hole) and twisted ankle.","sourceDate":"2018-09-06"},{"SOURCE_ROW_NUMBER":"269489","DOCUMENT_NO":"220180250076","ACCIDENT_DT":"01/22/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Crane operator, Mobile equipment operator (MEO), Dragline operator, Dropball operator, Rigger","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"HELPING CHANGE THE HOIST ROPE ON THE 7450 DRAGLINE. WAS REMOVING THE WEDGE FROM THE HOIST CABLE SOCKET USING A RUBBER SLEDGE HAMMER WHEN EMPLOYEE INJURED ARM WHILE SWINGING.","sourceDate":"2018-01-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-05-11","lastDate":"2017-05-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":84,"firstDate":"2006-10-23","lastDate":"2026-06-24","metrics":{"ss":8,"delinquent":82,"recentRows":18,"paidPenalty":10134,"proposedPenalty":10932,"currentAssessment":10134},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2916853","VIOLATION_NO":"9603015","ISSUE_DT":"06/24/2026","CFR_STANDARD_CD":"50.30(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"2916852","VIOLATION_NO":"9603014","ISSUE_DT":"06/24/2026","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"2922019","VIOLATION_NO":"5155604","ISSUE_DT":"01/21/2026","CFR_STANDARD_CD":"47.41(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-01-21"},{"SOURCE_ROW_NUMBER":"1316656","VIOLATION_NO":"9209924","ISSUE_DT":"12/17/2024","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-12-17"},{"SOURCE_ROW_NUMBER":"1316655","VIOLATION_NO":"9209923","ISSUE_DT":"12/17/2024","CFR_STANDARD_CD":"41.12","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-12-17"},{"SOURCE_ROW_NUMBER":"1316881","VIOLATION_NO":"9209150","ISSUE_DT":"06/11/2024","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-06-11"},{"SOURCE_ROW_NUMBER":"1316411","VIOLATION_NO":"9209120","ISSUE_DT":"10/24/2023","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-10-24"},{"SOURCE_ROW_NUMBER":"1316290","VIOLATION_NO":"8005966","ISSUE_DT":"06/07/2023","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"143.00","CURRENT_ASSESSMENT_AMT":"143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-06-07"},{"SOURCE_ROW_NUMBER":"1316289","VIOLATION_NO":"8005965","ISSUE_DT":"06/05/2023","CFR_STANDARD_CD":"77.1607(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2023-06-05"},{"SOURCE_ROW_NUMBER":"1315703","VIOLATION_NO":"8005738","ISSUE_DT":"12/06/2022","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-12-06"},{"SOURCE_ROW_NUMBER":"1315702","VIOLATION_NO":"8005737","ISSUE_DT":"11/29/2022","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-11-29"},{"SOURCE_ROW_NUMBER":"1315114","VIOLATION_NO":"8005048","ISSUE_DT":"08/09/2022","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-08-09"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2011-03-22","lastDate":"2012-02-16","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":751,"originalPenalty":1549},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"79828","VIOLATION_NO":"6600385","DOCKET_NO":"PENN 2012-48","DECISION_DT":"02/16/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-02-16"},{"SOURCE_ROW_NUMBER":"265020","VIOLATION_NO":"7012010","DOCKET_NO":"PENN 2010-218","DECISION_DT":"03/22/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1449.00","DECISION_PENALTY_AMT":"651.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2011-03-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":466,"firstDate":"2006-10-25","lastDate":"2026-09-15","metrics":{"recentRows":153,"cpdmSamples":0,"voidSamples":9,"validSamples":457,"maxConcentration":4.088,"concentrationTotal":75.241},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"719906","CASS_NUM":"51665030","SMP_TAKEN_DT":"9/15/2026","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"849839","CASS_NUM":"51665107","SMP_TAKEN_DT":"9/10/2026","CONC":".158","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-09-10"},{"SOURCE_ROW_NUMBER":"1539374","CASS_NUM":"51665025","SMP_TAKEN_DT":"9/9/2026","CONC":".378","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"768117","CASS_NUM":"58589766","SMP_TAKEN_DT":"9/9/2026","CONC":".182","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"1660726","CASS_NUM":"51665032","SMP_TAKEN_DT":"8/4/2026","CONC":".101","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-08-04"},{"SOURCE_ROW_NUMBER":"1333253","CASS_NUM":"58587883","SMP_TAKEN_DT":"6/25/2026","CONC":".024","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"741292","CASS_NUM":"58587938","SMP_TAKEN_DT":"6/25/2026","CONC":".109","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OILER/GREASER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"558228","CASS_NUM":"58588136","SMP_TAKEN_DT":"6/25/2026","CONC":".078","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CRANE OPER/DRAGLINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"264178","CASS_NUM":"58587901","SMP_TAKEN_DT":"6/25/2026","CONC":".077","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-06-25"},{"SOURCE_ROW_NUMBER":"423906","CASS_NUM":"51665138","SMP_TAKEN_DT":"5/28/2026","CONC":".009","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-05-28"},{"SOURCE_ROW_NUMBER":"898491","CASS_NUM":"51665112","SMP_TAKEN_DT":"5/27/2026","CONC":".052","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"1291950","CASS_NUM":"51665026","SMP_TAKEN_DT":"5/26/2026","CONC":".103","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-05-26"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2026-10-06","lastDate":"2026-10-06","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2,"firstDate":"2009-11-04","lastDate":"2011-09-12","metrics":{"decisions":2,"ssChanged":0,"recentRows":0,"decisionPenalty":751,"proposedPenalty":1549},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"196342","CITATION_NO":"6600385","CITATION_ISSUE_DT":"09/12/2011","DOCKET_NO":"PENN 2012-48","DECISION_DT":"02/16/2012","CFR_STANDARD_CODE":"77.410(c)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"188973","CITATION_NO":"7012010","CITATION_ISSUE_DT":"11/04/2009","DOCKET_NO":"PENN 2010-218","DECISION_DT":"03/22/2011","CFR_STANDARD_CODE":"77.1000","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1449.00","DECISION_PENALTY_AMT":"651.00","sourceDate":"2009-11-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":575,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":159,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2006-03-22","lastDate":"2006-03-22","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":67,"firstDate":"2006-09-06","lastDate":"2026-09-09","metrics":{"inspectors":102,"recentRows":16,"onSiteHours":2589,"inspectionHours":3464.25,"inspectionSamples":399},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"939623","EVENT_NO":"F04E183","INSPECTION_BEGIN_DT":"09/09/2026","INSPECTION_END_DT":"09/09/2026","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"525416","EVENT_NO":"F005B05","INSPECTION_BEGIN_DT":"06/24/2026","INSPECTION_END_DT":"06/29/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"45.5","SUM_TOTAL_ON_SITE_HOURS":"37.75","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"957338","EVENT_NO":"F006FBC","INSPECTION_BEGIN_DT":"01/12/2026","INSPECTION_END_DT":"01/26/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"51.5","SUM_TOTAL_ON_SITE_HOURS":"40.5","sourceDate":"2026-01-12"},{"SOURCE_ROW_NUMBER":"419744","EVENT_NO":"F01809F","INSPECTION_BEGIN_DT":"07/08/2025","INSPECTION_END_DT":"07/30/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"63","SUM_TOTAL_ON_SITE_HOURS":"46","sourceDate":"2025-07-08"},{"SOURCE_ROW_NUMBER":"1057355","EVENT_NO":"4315098","INSPECTION_BEGIN_DT":"12/09/2024","INSPECTION_END_DT":"02/10/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"60","SUM_TOTAL_ON_SITE_HOURS":"48","sourceDate":"2024-12-09"},{"SOURCE_ROW_NUMBER":"1090421","EVENT_NO":"F00928E","INSPECTION_BEGIN_DT":"06/25/2024","INSPECTION_END_DT":"06/25/2024","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2024-06-25"},{"SOURCE_ROW_NUMBER":"503546","EVENT_NO":"4315370","INSPECTION_BEGIN_DT":"06/05/2024","INSPECTION_END_DT":"06/21/2024","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"48.5","SUM_TOTAL_ON_SITE_HOURS":"41","sourceDate":"2024-06-05"},{"SOURCE_ROW_NUMBER":"1127566","EVENT_NO":"4315368","INSPECTION_BEGIN_DT":"05/22/2024","INSPECTION_END_DT":"05/22/2024","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2024-05-22"},{"SOURCE_ROW_NUMBER":"794505","EVENT_NO":"4314931","INSPECTION_BEGIN_DT":"10/23/2023","INSPECTION_END_DT":"11/08/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"52","SUM_TOTAL_ON_SITE_HOURS":"40","sourceDate":"2023-10-23"},{"SOURCE_ROW_NUMBER":"113866","EVENT_NO":"4314813","INSPECTION_BEGIN_DT":"06/05/2023","INSPECTION_END_DT":"06/15/2023","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"33.5","SUM_TOTAL_ON_SITE_HOURS":"26.75","sourceDate":"2023-06-05"},{"SOURCE_ROW_NUMBER":"688632","EVENT_NO":"4314468","INSPECTION_BEGIN_DT":"05/17/2023","INSPECTION_END_DT":"05/17/2023","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2023-05-17"},{"SOURCE_ROW_NUMBER":"568361","EVENT_NO":"4314181","INSPECTION_BEGIN_DT":"11/28/2022","INSPECTION_END_DT":"12/14/2022","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"60.75","SUM_TOTAL_ON_SITE_HOURS":"46","sourceDate":"2022-11-28"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":79,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":11542,"employees":22,"production":25782},"2026-Q1":{"hours":11709,"employees":23,"production":17682},"2025-Q4":{"hours":12512,"employees":23,"production":21125},"2025-Q3":{"hours":15096,"employees":28,"production":38837},"2025-Q2":{"hours":14886,"employees":27,"production":43701},"2025-Q1":{"hours":14640,"employees":26,"production":41775},"2024-Q4":{"hours":15239,"employees":26,"production":28734},"2024-Q3":{"hours":16000,"employees":26,"production":24699},"2024-Q2":{"hours":15137,"employees":26,"production":41330},"2024-Q1":{"hours":14047,"employees":24,"production":65962},"2023-Q4":{"hours":12939,"employees":25,"production":56343},"2023-Q3":{"hours":15510,"employees":27,"production":47399}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":37986,"employees":22,"production":115469},"2018":{"hours":44930,"employees":22,"production":127200},"2019":{"hours":52782,"employees":25,"production":109174},"2020":{"hours":54648,"employees":27,"production":140279},"2021":{"hours":56872,"employees":26,"production":156677},"2022":{"hours":63294,"employees":28,"production":155347},"2023":{"hours":58862,"employees":25,"production":189438},"2024":{"hours":60423,"employees":26,"production":160725},"2025":{"hours":57134,"employees":26,"production":145438},"2026":{"hours":23251,"employees":23,"production":43464}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":174,"firstDate":"2006-10-23","lastDate":"2026-09-09","metrics":{"recentRows":61,"doseOver100":2,"actDoseTotal":4932,"pelDoseTotal":1926},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"172865","EVENT_NO":"F04E183","SURVEY_DATE":"09/09/2026","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","ACT_DOSE_85":"13","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"172864","EVENT_NO":"F006FBC","SURVEY_DATE":"01/21/2026","OCCUPATION_CD_DESC":"OILER/GREASER","MACHINE_CD":"40","ACT_DOSE_85":"99","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2026-01-21"},{"SOURCE_ROW_NUMBER":"172863","EVENT_NO":"F006FBC","SURVEY_DATE":"01/21/2026","OCCUPATION_CD_DESC":"CRANE OPER/DRAGLINE OPERATOR","MACHINE_CD":"12","ACT_DOSE_85":"27","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2026-01-21"},{"SOURCE_ROW_NUMBER":"172862","EVENT_NO":"F006FBC","SURVEY_DATE":"01/20/2026","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"40","ACT_DOSE_85":"20","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-01-20"},{"SOURCE_ROW_NUMBER":"172861","EVENT_NO":"F006FBC","SURVEY_DATE":"01/20/2026","OCCUPATION_CD_DESC":"COAL TRUCK DRIVER","MACHINE_CD":"39","ACT_DOSE_85":"22","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2026-01-20"},{"SOURCE_ROW_NUMBER":"172860","EVENT_NO":"F006FBC","SURVEY_DATE":"01/20/2026","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"7","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-01-20"},{"SOURCE_ROW_NUMBER":"172859","EVENT_NO":"F006FBC","SURVEY_DATE":"01/14/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"40","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2026-01-14"},{"SOURCE_ROW_NUMBER":"172858","EVENT_NO":"F006FBC","SURVEY_DATE":"01/14/2026","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"7","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-01-14"},{"SOURCE_ROW_NUMBER":"172857","EVENT_NO":"F006FBC","SURVEY_DATE":"01/14/2026","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","ACT_DOSE_85":"8","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2026-01-14"},{"SOURCE_ROW_NUMBER":"172856","EVENT_NO":"F006FBC","SURVEY_DATE":"01/14/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"18","ACT_DOSE_85":"23","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-01-14"},{"SOURCE_ROW_NUMBER":"172848","EVENT_NO":"4315098","SURVEY_DATE":"01/22/2025","OCCUPATION_CD_DESC":"CRANE OPER/DRAGLINE OPERATOR","MACHINE_CD":"12","ACT_DOSE_85":"12","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2025-01-22"},{"SOURCE_ROW_NUMBER":"172847","EVENT_NO":"4315098","SURVEY_DATE":"01/22/2025","OCCUPATION_CD_DESC":"OILER/GREASER","MACHINE_CD":"40","ACT_DOSE_85":"95","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2025-01-22"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":28,"firstDate":"2006-10-25","lastDate":"2026-09-09","metrics":{"recentRows":5,"voidSamples":1,"maxQuartzPct":39,"validSamples":27,"quartzPctTotal":405.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"80998","CASSETTE_NO":"58589766","SAMPLE_DT":"09/09/2026","QUARTZ_PCT":"01.4","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-09-09"},{"SOURCE_ROW_NUMBER":"138443","CASSETTE_NO":"58570315","SAMPLE_DT":"07/09/2025","QUARTZ_PCT":"10.8","QUARTZ_MICROGRAMS":"31","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-07-09"},{"SOURCE_ROW_NUMBER":"2823","CASSETTE_NO":"58494923","SAMPLE_DT":"06/07/2023","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2023-06-07"},{"SOURCE_ROW_NUMBER":"166730","CASSETTE_NO":"58342427","SAMPLE_DT":"07/22/2021","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-07-22"},{"SOURCE_ROW_NUMBER":"118920","CASSETTE_NO":"58403967","SAMPLE_DT":"01/11/2021","QUARTZ_PCT":"00.5","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"STRIPPING SHOVEL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2021-01-11"},{"SOURCE_ROW_NUMBER":"30418","CASSETTE_NO":"58341607","SAMPLE_DT":"09/15/2020","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-09-15"},{"SOURCE_ROW_NUMBER":"64775","CASSETTE_NO":"58375083","SAMPLE_DT":"01/14/2020","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2020-01-14"},{"SOURCE_ROW_NUMBER":"33045","CASSETTE_NO":"58343075","SAMPLE_DT":"07/16/2019","QUARTZ_PCT":"19.4","QUARTZ_MICROGRAMS":"49","OCC_CODE_DESC":"STRIPPING SHOVEL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-16"},{"SOURCE_ROW_NUMBER":"46516","CASSETTE_NO":"58344464","SAMPLE_DT":"03/12/2019","QUARTZ_PCT":"00.5","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-03-12"},{"SOURCE_ROW_NUMBER":"143699","CASSETTE_NO":"58289682","SAMPLE_DT":"06/26/2018","QUARTZ_PCT":"18.0","QUARTZ_MICROGRAMS":"56","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-06-26"},{"SOURCE_ROW_NUMBER":"155325","CASSETTE_NO":"58244203","SAMPLE_DT":"01/08/2018","QUARTZ_PCT":"04.6","QUARTZ_MICROGRAMS":"63","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-01-08"},{"SOURCE_ROW_NUMBER":"101153","CASSETTE_NO":"58319208","SAMPLE_DT":"06/08/2017","QUARTZ_PCT":"39.0","QUARTZ_MICROGRAMS":"93","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-06-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":86,"firstDate":"2006-10-23","lastDate":"2026-06-29","metrics":{"ss":8,"amountDue":10134,"contested":1,"amountPaid":10134,"recentRows":19,"section104d":0,"unterminated":0,"proposedPenalty":10932},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1985521","VIOLATION_NO":"9603016","VIOLATION_ISSUE_DT":"06/29/2026","SIG_SUB":"N","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/29/2026","CONTESTED_IND":"N","sourceDate":"2026-06-29"},{"SOURCE_ROW_NUMBER":"1985520","VIOLATION_NO":"9603015","VIOLATION_ISSUE_DT":"06/24/2026","SIG_SUB":"N","PART_SECTION":"50.30(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/24/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"1985519","VIOLATION_NO":"9603014","VIOLATION_ISSUE_DT":"06/24/2026","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/24/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-06-24"},{"SOURCE_ROW_NUMBER":"1985473","VIOLATION_NO":"5155604","VIOLATION_ISSUE_DT":"01/21/2026","SIG_SUB":"N","PART_SECTION":"47.41(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/21/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-01-21"},{"SOURCE_ROW_NUMBER":"1985552","VIOLATION_NO":"9209924","VIOLATION_ISSUE_DT":"12/17/2024","SIG_SUB":"N","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/17/2024","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2024-12-17"},{"SOURCE_ROW_NUMBER":"1985551","VIOLATION_NO":"9209923","VIOLATION_ISSUE_DT":"12/17/2024","SIG_SUB":"N","PART_SECTION":"41.12","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/14/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2024-12-17"},{"SOURCE_ROW_NUMBER":"1985510","VIOLATION_NO":"9209150","VIOLATION_ISSUE_DT":"06/11/2024","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/11/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-06-11"},{"SOURCE_ROW_NUMBER":"1985541","VIOLATION_NO":"9209120","VIOLATION_ISSUE_DT":"10/24/2023","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/24/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-10-24"},{"SOURCE_ROW_NUMBER":"1985509","VIOLATION_NO":"8005966","VIOLATION_ISSUE_DT":"06/07/2023","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2023","PROPOSED_PENALTY":"143","AMOUNT_DUE":"143","AMOUNT_PAID":"143","CONTESTED_IND":"N","sourceDate":"2023-06-07"},{"SOURCE_ROW_NUMBER":"1985508","VIOLATION_NO":"8005965","VIOLATION_ISSUE_DT":"06/05/2023","SIG_SUB":"N","PART_SECTION":"77.1607(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/05/2023","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2023-06-05"},{"SOURCE_ROW_NUMBER":"1985550","VIOLATION_NO":"8005738","VIOLATION_ISSUE_DT":"12/06/2022","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/07/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-12-06"},{"SOURCE_ROW_NUMBER":"1985549","VIOLATION_NO":"8005737","VIOLATION_ISSUE_DT":"11/29/2022","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/29/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-11-29"}]}],"safety":{"href":"/api/v1/mines/3609401/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609401/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":26,"companyType":"Independent Producer Operator","components":[{"averageEmployees":26,"laborHours":60423,"mineType":"Surface","productionTons":160725}],"county":"Schuylkill","laborHours":60423,"mineName":"Primrose Operation","mineType":"Surface","mshaId":"3609401","operatingAddress":"Route 54, P.O. Box 12, Mahanoy City, PA 17948","operatingCompany":"Blaschak Anthracite Corporatio","operationType":"Mine only","productionTons":160725,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Pennsylvania (Anthracite)","status":"Active","supplyRegion":"Appalachia Northern","union":"United Mine Workers Of America","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","heading":"Preparation and submission of MSHA Form 7000-2—Quarterly Employment and Coal Production Report.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-D/section-50.30","part":"50","subchapter":"I","subpart":"D","id":"50.30","citation":"30 CFR 50.30","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 47.41","heading":"Requirement for container labels.","id":"47.41","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-47/subpart-E/section-47.41","part":"47","partHeading":"PART 47—HAZARD COMMUNICATION (HazCom)","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"E","subpartHeading":"Subpart E—Container Labels and Other Forms of Warning","text":"(a) The operator must ensure that each container of a hazardous chemical has a label. If a container is tagged or marked with the appropriate information, it is labeled.\n\n(1) The operator must replace a container label immediately if it is missing or if the hazard information on the label is unreadable.\n\n(2) The operator must not remove or deface existing labels on containers of hazardous chemicals.\n\n(b) For each hazardous chemical produced at the mine, the operator must prepare a container label and update this label with any significant, new information about the chemical's hazards within 3 months of becoming aware of this information.\n\n(c) For each hazardous chemical brought to the mine, the operator must replace an outdated label when a revised label is received from the chemical's manufacturer or supplier. The operator is not responsible for an inaccurate label obtained from the chemical's manufacturer or supplier.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","heading":"Changes; notification by operator.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-G/part-41/subpart-B/section-41.12","part":"41","subchapter":"G","subpart":"B","id":"41.12","citation":"30 CFR 41.12","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER G—FILING AND OTHER ADMINISTRATIVE REQUIREMENTS","partHeading":"PART 41—NOTIFICATION OF LEGAL IDENTITY","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1607","heading":"Loading and haulage equipment; operation.","id":"77.1607","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1607","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Vehicles shall follow at a safe distance; passing shall be limited to areas of adequate clearance and visibility.\n\n(b) Mobile equipment operators shall have full control of the equipment while it is in motion.\n\n(c) Equipment operating speeds shall be prudent and consistent with conditions of roadway, grades, clearance, visibility, traffic, and the type of equipment used.\n\n(d) Cabs of mobile equipment shall be kept free of extraneous materials.\n\n(e) Operators shall sit facing the direction of travel while operating equipment with dual controls.\n\n(f) When an equipment operator is present, men shall notify him before getting on or off equipment.\n\n(g) Equipment operators shall be certain, by signal or other means, that all persons are clear before starting or moving equipment.\n\n(h) Where possible, aerial tramways shall not be started until the tramway operator has ascertained that everyone is in the clear.\n\n(i) Dust control measures shall be taken where dust significantly reduces visibility of equipment operators.\n\n(j) Dippers, buckets, loading booms, or heavy suspended loads shall not be swung over the cabs of haulage vehicles until the drivers are out of the cabs and in safe locations, unless the trucks are designed specifically to protect the drivers from falling material.\n\n(k) Men shall not work or pass under the buckets or booms of loaders in operation.\n\n(l) Tires shall be deflated before repairs on them are started and adequate means shall be provided to prevent wheel locking rims from creating a hazard during tire inflation.\n\n(m) Electrically powered mobile equipment shall not be left unattended unless the master switch is in the off position, all operating controls are in the neutral position, and the brakes are set or other equivalent precautions are taken against rolling.\n\n(n) Mobile equipment shall not be left unattended unless the brakes are set. The wheels shall be turned into a bank or berm, or shall be blocked, when such equipment is parked on a grade.\n\n(o) Lights, flares, or other warning devices shall be posted when parked equipment creates a hazard to vehicular traffic.\n\n(p) Dippers, buckets, scraper blades, and similar movable parts shall be secured or lowered to the ground when not in use.\n\n(q) Shovel trailing cables shall not be moved with the shovel dipper unless cable slings or sleds are used.\n\n(r) Equipment which is to be hauled shall be loaded and protected so as to prevent sliding or spillage.\n\n(s) When moving between work areas, the equipment shall be secured in the travel position.\n\n(t) Any load extending more than 4 feet beyond the rear of the vehicle body should be marked clearly with a red flag by day and a red light at night.\n\n(u) Tow bars shall be used to tow heavy equipment and a safety chain shall be used in conjunction with each tow bar.\n\n(v) Railroad cars shall be kept under control at all times by the car dropper. Cars shall be dropped at a safe rate and in a manner that will insure that the car dropper maintains a safe position while working and traveling around the cars.\n\n(w) Railroad cars shall not be coupled or uncoupled manually from the inside of curves unless the railroad and cars are so designed to eliminate any hazard from coupling or uncoupling cars from inside of curves.\n\n(x) Persons shall wear safety belts when dropping railroad cars.\n\n(y) Railcars shall not be left on sidetracks unless ample clearance is provided for traffic on adjacent tracks.\n\n(z) Parked railcars, unless held effectively by brakes, shall be blocked securely.\n\n(aa) Railroad cars and all trucks shall be trimmed properly when they have been loaded higher than the confines of their cargo space.\n\n(bb) When the entire length of a conveyor is visible from the starting switch, the operator shall visually check to make certain that all persons are in the clear before starting the conveyor. When the entire length of the conveyor is not visible from the starting switch, a positive audible or visible warning system shall be installed and operated to warn persons that the conveyor will be started.\n\n(cc) Unguarded conveyors with walkways shall be equipped with emergency stop devices or cords along their full length.\n\n(dd) Adequate backstops or brakes shall be installed on inclined-conveyor drive units to prevent conveyors from running in reverse if a hazard to personnel would be caused.\n\n(ee) Aerial tram conveyor buckets shall not be overloaded, and feed shall be regulated to prevent spillage.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609401","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}