{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3609394","name":"KNOB CREEK","status":"Active","status_date":"2020-02-05","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Indiana","nearest_town":"Jacksonville, PA","operator_id":"P09635","operator_name":"ROSEBUD MINING COMPANY","controller_id":"C07485","controller_name":"J Clifford  Forrest III","district":"C03","office":"Indiana PA Field Office","employees":22,"latitude":40.525278,"longitude":-79.331667},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":6380},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609394","name":"KNOB CREEK"},"operator":{"type":"operator","id":"P09635","name":"ROSEBUD MINING COMPANY"},"controller":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"mine","id":"3609394","name":"KNOB CREEK"},"validFrom":"1979-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609394|C07485|1979-08-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0096046","name":"Western Allegheney Energy, LLC."},"object":{"type":"mine","id":"3609394","name":"KNOB CREEK"},"validFrom":"2008-10-22","validTo":"2011-06-20","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609394|0096046|2008-10-22|2011-06-20"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"mine","id":"3609394","name":"KNOB CREEK"},"validFrom":"2008-10-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609394|C07485|2008-10-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"operator","id":"0096046","name":"Western Allegheney Energy, LLC."},"validFrom":"2008-10-22","validTo":"2011-06-20","current":false,"derived":true,"evidenceMineId":"3609394","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609394|0096046|2008-10-22|C07485|2008-10-22|74835"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"object":{"type":"mine","id":"3609394","name":"KNOB CREEK"},"validFrom":"2011-06-21","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609394|P09635|2011-06-21|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"validFrom":"2011-06-21","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609394","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609394|P09635|2011-06-21|C07485|1979-08-01|74808"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":32,"firstDate":"2011-09-28","lastDate":"2026-09-11","metrics":{"daysLost":1243,"injuries":27,"fatalities":0,"recentRows":7,"restrictedDays":44,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"248041","DOCUMENT_NO":"220262600003","ACCIDENT_DT":"09/11/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Individual was installing the roof bolt into the roof when the channel plate slid down the bolt and lacerated EE's forearm, resulting in sutures.","sourceDate":"2026-09-11"},{"SOURCE_ROW_NUMBER":"269488","DOCUMENT_NO":"220260260013","ACCIDENT_DT":"01/15/2026","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was getting a T3 Channel off of the center of the bolter when the stack of T3s shifted smashing a finger and causing a laceration which required sutures.","sourceDate":"2026-01-15"},{"SOURCE_ROW_NUMBER":"11468","DOCUMENT_NO":"220212230022","ACCIDENT_DT":"07/24/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"38","NARRATIVE":"Employee was lifting an I-Beam from the bottom onto the overcast when EE felt pain in right shoulder. The individual worked until 7/26/2021 making the incident a lost time injury.","sourceDate":"2021-07-24"},{"SOURCE_ROW_NUMBER":"170607","DOCUMENT_NO":"220212010011","ACCIDENT_DT":"07/06/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"30","NARRATIVE":"After lifting the spilboard EE went to get off the belt. EE felt the pain in back and felt numbness in leg.","sourceDate":"2021-07-06"},{"SOURCE_ROW_NUMBER":"45816","DOCUMENT_NO":"220212390035","ACCIDENT_DT":"06/23/2021","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"30","NARRATIVE":"The employee has developed carpal tunnel from repetitive motion and crawling over years of work. The employee worked until surgery on 8/17/2021.","sourceDate":"2021-06-23"},{"SOURCE_ROW_NUMBER":"265257","DOCUMENT_NO":"220211590013","ACCIDENT_DT":"06/02/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"176","NARRATIVE":"Was wet and muddy, EE was getting on the loader, slipped on a step causing EE to fall. Grabbed railing with right arm causing pressure on shoulder.","sourceDate":"2021-06-02"},{"SOURCE_ROW_NUMBER":"230820","DOCUMENT_NO":"220210150010","ACCIDENT_DT":"01/12/2021","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall was discovered during the morning preshift in the face of #3 entry in 14 Butt (two crosscuts inby spad #6003).  The fall measured approximately 18 ft by 75 ft by 6 ft. The fall appears to have occurred as a result of a cutter that formed in a geologic transition zone.","sourceDate":"2021-01-12"},{"SOURCE_ROW_NUMBER":"88807","DOCUMENT_NO":"220203090004","ACCIDENT_DT":"10/21/2020","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Unintentional fall above anchor point in 9 Butt near spad #4869. The fall measured approximately 18 ft by 95 ft by 6 ft. The fall occurred as a result of a cutter that formed in a geologic transition zone several weeks after development.","sourceDate":"2020-10-21"},{"SOURCE_ROW_NUMBER":"54371","DOCUMENT_NO":"220201740009","ACCIDENT_DT":"03/17/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"256","NARRATIVE":"The individual was removing rock from the miner when EE felt a strain in EE's back.  This occurred on 3/17 and the individual worked until 6/12/2020.","sourceDate":"2020-03-17"},{"SOURCE_ROW_NUMBER":"45817","DOCUMENT_NO":"220201610003","ACCIDENT_DT":"01/30/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"21","NARRATIVE":"Individual was sitting filling out pre-shift books.  When EE stood up EE felt a pop in EE's knee.  EE went into surgery on 6/3/2020 resulting in a loss time injury.","sourceDate":"2020-01-30"},{"SOURCE_ROW_NUMBER":"174890","DOCUMENT_NO":"220200130011","ACCIDENT_DT":"01/10/2020","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was attempting to take water supply tree off 4\" main water line, when it came loose and struck them in the chin","sourceDate":"2020-01-10"},{"SOURCE_ROW_NUMBER":"75951","DOCUMENT_NO":"220193300021","ACCIDENT_DT":"11/21/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While rib bolting the individual was pushing up a bolt when the individual pinched left index finger between the roof plate and the bolt resulting in stitches.","sourceDate":"2019-11-21"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-02-05","lastDate":"2020-02-05","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":452,"firstDate":"2008-11-05","lastDate":"2026-08-26","metrics":{"ss":91,"delinquent":439,"recentRows":117,"paidPenalty":95265.4,"proposedPenalty":117307,"currentAssessment":96602.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3018767","VIOLATION_NO":"9607444","ISSUE_DT":"08/26/2026","CFR_STANDARD_CD":"70.209(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"3018766","VIOLATION_NO":"9607443","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"3018765","VIOLATION_NO":"9605430","ISSUE_DT":"08/06/2026","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"1667714","VIOLATION_NO":"9605365","ISSUE_DT":"05/20/2026","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"1667713","VIOLATION_NO":"9605364","ISSUE_DT":"05/12/2026","CFR_STANDARD_CD":"77.408","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-05-12"},{"SOURCE_ROW_NUMBER":"1667716","VIOLATION_NO":"9607329","ISSUE_DT":"05/04/2026","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-05-04"},{"SOURCE_ROW_NUMBER":"1667715","VIOLATION_NO":"9607327","ISSUE_DT":"04/14/2026","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-04-14"},{"SOURCE_ROW_NUMBER":"1667712","VIOLATION_NO":"9605362","ISSUE_DT":"04/10/2026","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-04-10"},{"SOURCE_ROW_NUMBER":"3018744","VIOLATION_NO":"9605473","ISSUE_DT":"03/11/2026","CFR_STANDARD_CD":"75.333(e)(1)(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-11"},{"SOURCE_ROW_NUMBER":"3018743","VIOLATION_NO":"9605472","ISSUE_DT":"03/03/2026","CFR_STANDARD_CD":"75.380(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-03"},{"SOURCE_ROW_NUMBER":"3018742","VIOLATION_NO":"9605471","ISSUE_DT":"03/03/2026","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-03"},{"SOURCE_ROW_NUMBER":"3018747","VIOLATION_NO":"9607317","ISSUE_DT":"02/03/2026","CFR_STANDARD_CD":"75.1103-5(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-02-03"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":86,"firstDate":"2010-11-09","lastDate":"2025-05-08","metrics":{"appeals":0,"decisions":86,"recentRows":3,"decisionPenalty":41771.4,"originalPenalty":63916},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"163298","VIOLATION_NO":"9207721","DOCKET_NO":"PENN 2025-0057","DECISION_DT":"05/08/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4383.00","DECISION_PENALTY_AMT":"1773.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2025-05-08"},{"SOURCE_ROW_NUMBER":"429769","VIOLATION_NO":"7027121","DOCKET_NO":"PENN 2022-0005","DECISION_DT":"01/26/2022","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"622.00","DECISION_PENALTY_AMT":"622.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2022-01-26"},{"SOURCE_ROW_NUMBER":"425825","VIOLATION_NO":"9072421","DOCKET_NO":"PENN 2021-0040","DECISION_DT":"05/19/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"378.00","DECISION_PENALTY_AMT":"378.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2021-05-19"},{"SOURCE_ROW_NUMBER":"137667","VIOLATION_NO":"7031144","DOCKET_NO":"PENN 2019-0068","DECISION_DT":"04/30/2019","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"589.00","DECISION_PENALTY_AMT":"589.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2019-04-30"},{"SOURCE_ROW_NUMBER":"401068","VIOLATION_NO":"9072090","DOCKET_NO":"PENN 2018-0149","DECISION_DT":"08/02/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4717.00","DECISION_PENALTY_AMT":"2830.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2018-08-02"},{"SOURCE_ROW_NUMBER":"398796","VIOLATION_NO":"7031103","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"116.00","DECISION_PENALTY_AMT":"116.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-03-23"},{"SOURCE_ROW_NUMBER":"398271","VIOLATION_NO":"7031350","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"160.00","DECISION_PENALTY_AMT":"144.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-03-23"},{"SOURCE_ROW_NUMBER":"130498","VIOLATION_NO":"7031104","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"356.00","DECISION_PENALTY_AMT":"356.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-03-23"},{"SOURCE_ROW_NUMBER":"130403","VIOLATION_NO":"7031102","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"160.00","DECISION_PENALTY_AMT":"144.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2018-03-23"},{"SOURCE_ROW_NUMBER":"128095","VIOLATION_NO":"9072076","DOCKET_NO":"PENN 2017-0210","DECISION_DT":"12/15/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"550.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2017-12-15"},{"SOURCE_ROW_NUMBER":"390043","VIOLATION_NO":"7031329","DOCKET_NO":"PENN 2017-0077","DECISION_DT":"07/25/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"568.00","DECISION_PENALTY_AMT":"568.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-25"},{"SOURCE_ROW_NUMBER":"389245","VIOLATION_NO":"7031328","DOCKET_NO":"PENN 2017-0077","DECISION_DT":"07/25/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"324.00","DECISION_PENALTY_AMT":"227.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-25"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":3739,"firstDate":"2008-11-04","lastDate":"2026-10-07","metrics":{"recentRows":1746,"cpdmSamples":2806,"voidSamples":1062,"validSamples":2677,"maxConcentration":22.233,"concentrationTotal":2210.281},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2603621","SMP_TAKEN_DT":"10/7/2026","CONC":".045","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"},{"SOURCE_ROW_NUMBER":"2005604","SMP_TAKEN_DT":"10/6/2026","CONC":".965","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"2176325","SMP_TAKEN_DT":"10/2/2026","CONC":".619","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-02"},{"SOURCE_ROW_NUMBER":"2517107","SMP_TAKEN_DT":"10/1/2026","CONC":".92","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"2688810","SMP_TAKEN_DT":"9/30/2026","CONC":".744","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"2347470","SMP_TAKEN_DT":"9/30/2026","CONC":".716","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"1751112","SMP_TAKEN_DT":"9/29/2026","CONC":".403","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-29"},{"SOURCE_ROW_NUMBER":"2602226","SMP_TAKEN_DT":"9/28/2026","CONC":".766","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"2176925","SMP_TAKEN_DT":"9/28/2026","CONC":".526","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"2603994","SMP_TAKEN_DT":"9/23/2026","CONC":".824","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"1751759","SMP_TAKEN_DT":"9/23/2026","CONC":".915","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-23"},{"SOURCE_ROW_NUMBER":"2347058","SMP_TAKEN_DT":"9/22/2026","CONC":".6","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-09-22"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":4,"firstDate":"2010-11-09","lastDate":"2014-10-29","metrics":{"linkedIssuances":4},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":86,"firstDate":"2009-11-16","lastDate":"2024-10-10","metrics":{"decisions":86,"ssChanged":27,"recentRows":2,"decisionPenalty":41771.4,"proposedPenalty":63916},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"222460","CITATION_NO":"9207721","CITATION_ISSUE_DT":"10/10/2024","DOCKET_NO":"PENN 2025-0057","DECISION_DT":"05/08/2025","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4383.00","DECISION_PENALTY_AMT":"1773.00","sourceDate":"2024-10-10"},{"SOURCE_ROW_NUMBER":"274957","CITATION_NO":"7027121","CITATION_ISSUE_DT":"07/21/2021","DOCKET_NO":"PENN 2022-0005","DECISION_DT":"01/26/2022","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"622.00","DECISION_PENALTY_AMT":"622.00","sourceDate":"2021-07-21"},{"SOURCE_ROW_NUMBER":"103747","CITATION_NO":"9072421","CITATION_ISSUE_DT":"11/18/2020","DOCKET_NO":"PENN 2021-0040","DECISION_DT":"05/19/2021","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"378.00","DECISION_PENALTY_AMT":"378.00","sourceDate":"2020-11-18"},{"SOURCE_ROW_NUMBER":"271386","CITATION_NO":"7031144","CITATION_ISSUE_DT":"11/27/2018","DOCKET_NO":"PENN 2019-0068","DECISION_DT":"04/30/2019","CFR_STANDARD_CODE":"75.1714(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"589.00","DECISION_PENALTY_AMT":"589.00","sourceDate":"2018-11-27"},{"SOURCE_ROW_NUMBER":"268390","CITATION_NO":"9072090","CITATION_ISSUE_DT":"11/21/2017","DOCKET_NO":"PENN 2018-0149","DECISION_DT":"08/02/2018","CFR_STANDARD_CODE":"75.1505(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"4717.00","DECISION_PENALTY_AMT":"2830.00","sourceDate":"2017-11-21"},{"SOURCE_ROW_NUMBER":"326522","CITATION_NO":"7031103","CITATION_ISSUE_DT":"09/07/2017","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"116.00","DECISION_PENALTY_AMT":"116.00","sourceDate":"2017-09-07"},{"SOURCE_ROW_NUMBER":"324160","CITATION_NO":"7031104","CITATION_ISSUE_DT":"09/07/2017","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"356.00","DECISION_PENALTY_AMT":"356.00","sourceDate":"2017-09-07"},{"SOURCE_ROW_NUMBER":"97957","CITATION_NO":"7031102","CITATION_ISSUE_DT":"08/29/2017","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"160.00","DECISION_PENALTY_AMT":"144.00","sourceDate":"2017-08-29"},{"SOURCE_ROW_NUMBER":"97956","CITATION_NO":"7031350","CITATION_ISSUE_DT":"08/29/2017","DOCKET_NO":"PENN 2018-0072","DECISION_DT":"03/23/2018","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"160.00","DECISION_PENALTY_AMT":"144.00","sourceDate":"2017-08-29"},{"SOURCE_ROW_NUMBER":"98067","CITATION_NO":"9072076","CITATION_ISSUE_DT":"05/08/2017","DOCKET_NO":"PENN 2017-0210","DECISION_DT":"12/15/2017","CFR_STANDARD_CODE":"75.1725(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"550.00","sourceDate":"2017-05-08"},{"SOURCE_ROW_NUMBER":"438142","CITATION_NO":"7031329","CITATION_ISSUE_DT":"10/25/2016","DOCKET_NO":"PENN 2017-0077","DECISION_DT":"07/25/2017","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"568.00","DECISION_PENALTY_AMT":"568.00","sourceDate":"2016-10-25"},{"SOURCE_ROW_NUMBER":"42095","CITATION_NO":"7031328","CITATION_ISSUE_DT":"10/12/2016","DOCKET_NO":"PENN 2017-0077","DECISION_DT":"07/25/2017","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"324.00","DECISION_PENALTY_AMT":"227.00","sourceDate":"2016-10-12"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":489,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":110,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2008-10-22","lastDate":"2011-06-21","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":317,"firstDate":"2008-11-04","lastDate":"2026-10-05","metrics":{"inspectors":484,"recentRows":185,"onSiteHours":11291.5,"inspectionHours":16566.5,"inspectionSamples":1737},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1071907","EVENT_NO":"F049F4C","INSPECTION_BEGIN_DT":"10/05/2026","INSPECTION_END_DT":"10/05/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"61988","EVENT_NO":"F03EB85","INSPECTION_BEGIN_DT":"09/30/2026","INSPECTION_END_DT":"09/30/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2026-09-30"},{"SOURCE_ROW_NUMBER":"894414","EVENT_NO":"F00F4BE","INSPECTION_BEGIN_DT":"09/28/2026","INSPECTION_END_DT":"09/28/2026","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-28"},{"SOURCE_ROW_NUMBER":"185151","EVENT_NO":"F049F46","INSPECTION_BEGIN_DT":"09/24/2026","INSPECTION_END_DT":"09/24/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-09-24"},{"SOURCE_ROW_NUMBER":"598340","EVENT_NO":"F049F43","INSPECTION_BEGIN_DT":"09/15/2026","INSPECTION_END_DT":"09/15/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-15"},{"SOURCE_ROW_NUMBER":"399204","EVENT_NO":"F02DA48","INSPECTION_BEGIN_DT":"08/31/2026","INSPECTION_END_DT":"08/31/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-08-31"},{"SOURCE_ROW_NUMBER":"364191","EVENT_NO":"F049F40","INSPECTION_BEGIN_DT":"08/10/2026","INSPECTION_END_DT":"08/10/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-08-10"},{"SOURCE_ROW_NUMBER":"717008","EVENT_NO":"F02DA3C","INSPECTION_BEGIN_DT":"07/29/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9.25","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-07-29"},{"SOURCE_ROW_NUMBER":"192723","EVENT_NO":"F037F58","INSPECTION_BEGIN_DT":"07/21/2026","INSPECTION_END_DT":"07/21/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-07-21"},{"SOURCE_ROW_NUMBER":"618809","EVENT_NO":"6245554","INSPECTION_BEGIN_DT":"07/20/2026","INSPECTION_END_DT":"08/10/2026","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"290302","EVENT_NO":"F028F80","INSPECTION_BEGIN_DT":"07/16/2026","INSPECTION_END_DT":"07/16/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2026-07-16"},{"SOURCE_ROW_NUMBER":"552929","EVENT_NO":"F037F55","INSPECTION_BEGIN_DT":"07/01/2026","INSPECTION_END_DT":"08/13/2026","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2026-07-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":142,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":13205,"employees":25,"production":24095},"2026-Q1":{"hours":13770,"employees":25,"production":13770},"2025-Q4":{"hours":21101,"employees":27,"production":46218},"2025-Q3":{"hours":21504,"employees":27,"production":25285},"2025-Q2":{"hours":21537,"employees":27,"production":62714},"2025-Q1":{"hours":22772,"employees":27,"production":57167},"2024-Q4":{"hours":15381,"employees":25,"production":21030},"2024-Q3":{"hours":13323,"employees":24,"production":21321},"2024-Q2":{"hours":13490,"employees":24,"production":26733},"2024-Q1":{"hours":13216,"employees":24,"production":32311},"2023-Q4":{"hours":11757,"employees":23,"production":33341},"2023-Q3":{"hours":11646,"employees":23,"production":40084}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":36,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":46754,"employees":19,"production":221386},"2018":{"hours":47459,"employees":19,"production":145254},"2019":{"hours":69481,"employees":29,"production":88554},"2020":{"hours":57074,"employees":26,"production":165864},"2021":{"hours":65273,"employees":27,"production":134557},"2022":{"hours":43645,"employees":18,"production":127016},"2023":{"hours":47388,"employees":21,"production":126999},"2024":{"hours":55410,"employees":24,"production":101395},"2025":{"hours":86914,"employees":27,"production":191384},"2026":{"hours":26975,"employees":25,"production":37865}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":196,"firstDate":"2008-11-05","lastDate":"2026-07-28","metrics":{"recentRows":70,"doseOver100":42,"actDoseTotal":11847,"pelDoseTotal":9218},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"172688","EVENT_NO":"F02DA3A","SURVEY_DATE":"07/28/2026","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"20","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"172687","EVENT_NO":"F02DA3A","SURVEY_DATE":"07/28/2026","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"6","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"172686","EVENT_NO":"F02DA3A","SURVEY_DATE":"07/28/2026","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"172655","EVENT_NO":"6245542","SURVEY_DATE":"05/14/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"48","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2026-05-14"},{"SOURCE_ROW_NUMBER":"172654","EVENT_NO":"6245542","SURVEY_DATE":"04/15/2026","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-04-15"},{"SOURCE_ROW_NUMBER":"172653","EVENT_NO":"6245542","SURVEY_DATE":"04/15/2026","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"17","ACT_DOSE_85":"1","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-04-15"},{"SOURCE_ROW_NUMBER":"172682","EVENT_NO":"F02DA34","SURVEY_DATE":"03/10/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"28","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2026-03-10"},{"SOURCE_ROW_NUMBER":"172685","EVENT_NO":"F02DA34","SURVEY_DATE":"01/12/2026","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"17","ACT_DOSE_85":"6","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-01-12"},{"SOURCE_ROW_NUMBER":"172684","EVENT_NO":"F02DA34","SURVEY_DATE":"01/12/2026","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-01-12"},{"SOURCE_ROW_NUMBER":"172683","EVENT_NO":"F02DA34","SURVEY_DATE":"01/12/2026","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"11","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2026-01-12"},{"SOURCE_ROW_NUMBER":"172681","EVENT_NO":"F02DA30","SURVEY_DATE":"12/22/2025","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"90","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2025-12-22"},{"SOURCE_ROW_NUMBER":"172680","EVENT_NO":"F02DA30","SURVEY_DATE":"12/22/2025","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"80","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2025-12-22"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":228,"firstDate":"2010-09-21","lastDate":"2026-08-20","metrics":{"recentRows":117,"voidSamples":10,"maxQuartzPct":12.5,"validSamples":218,"quartzPctTotal":672.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"144088","CASSETTE_NO":"58600866","SAMPLE_DT":"08/20/2026","QUARTZ_PCT":"02.3","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"128308","CASSETTE_NO":"58601295","SAMPLE_DT":"08/20/2026","QUARTZ_PCT":"00.9","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"93685","CASSETTE_NO":"58601281","SAMPLE_DT":"08/20/2026","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"89201","CASSETTE_NO":"58601279","SAMPLE_DT":"08/20/2026","QUARTZ_PCT":"01.9","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"88656","CASSETTE_NO":"58601278","SAMPLE_DT":"08/20/2026","QUARTZ_PCT":"02.0","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-08-20"},{"SOURCE_ROW_NUMBER":"156205","CASSETTE_NO":"58596531","SAMPLE_DT":"04/28/2026","QUARTZ_PCT":"02.2","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"142030","CASSETTE_NO":"58596580","SAMPLE_DT":"04/28/2026","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"107666","CASSETTE_NO":"58596511","SAMPLE_DT":"04/28/2026","QUARTZ_PCT":"02.5","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"100301","CASSETTE_NO":"58596593","SAMPLE_DT":"04/28/2026","QUARTZ_PCT":"03.2","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"90900","CASSETTE_NO":"58596583","SAMPLE_DT":"04/28/2026","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-04-28"},{"SOURCE_ROW_NUMBER":"158327","CASSETTE_NO":"58565290","SAMPLE_DT":"01/27/2026","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-01-27"},{"SOURCE_ROW_NUMBER":"123761","CASSETTE_NO":"58564885","SAMPLE_DT":"01/27/2026","QUARTZ_PCT":"01.6","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-01-27"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":459,"firstDate":"2008-11-05","lastDate":"2026-09-03","metrics":{"ss":92,"amountDue":96602.4,"contested":20,"amountPaid":95265.4,"recentRows":121,"section104d":0,"unterminated":0,"proposedPenalty":117307},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1985103","VIOLATION_NO":"9607447","VIOLATION_ISSUE_DT":"09/03/2026","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/03/2026","CONTESTED_IND":"N","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"1985102","VIOLATION_NO":"9607446","VIOLATION_ISSUE_DT":"09/03/2026","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/03/2026","CONTESTED_IND":"N","sourceDate":"2026-09-03"},{"SOURCE_ROW_NUMBER":"1985101","VIOLATION_NO":"9607445","VIOLATION_ISSUE_DT":"09/01/2026","SIG_SUB":"N","PART_SECTION":"75.1103-8(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/01/2026","CONTESTED_IND":"N","sourceDate":"2026-09-01"},{"SOURCE_ROW_NUMBER":"1985100","VIOLATION_NO":"9607444","VIOLATION_ISSUE_DT":"08/26/2026","SIG_SUB":"N","PART_SECTION":"70.209(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/26/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-26"},{"SOURCE_ROW_NUMBER":"1985099","VIOLATION_NO":"9607443","VIOLATION_ISSUE_DT":"08/25/2026","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/25/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"1985098","VIOLATION_NO":"9605430","VIOLATION_ISSUE_DT":"08/06/2026","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/10/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-06"},{"SOURCE_ROW_NUMBER":"1984998","VIOLATION_NO":"9605365","VIOLATION_ISSUE_DT":"05/20/2026","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/20/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-05-20"},{"SOURCE_ROW_NUMBER":"1984997","VIOLATION_NO":"9605364","VIOLATION_ISSUE_DT":"05/12/2026","SIG_SUB":"N","PART_SECTION":"77.408","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/12/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-05-12"},{"SOURCE_ROW_NUMBER":"1985000","VIOLATION_NO":"9607329","VIOLATION_ISSUE_DT":"05/04/2026","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/04/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-05-04"},{"SOURCE_ROW_NUMBER":"1984999","VIOLATION_NO":"9607327","VIOLATION_ISSUE_DT":"04/14/2026","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/14/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-04-14"},{"SOURCE_ROW_NUMBER":"1984996","VIOLATION_NO":"9605362","VIOLATION_ISSUE_DT":"04/10/2026","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/10/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-04-10"},{"SOURCE_ROW_NUMBER":"1984949","VIOLATION_NO":"9605473","VIOLATION_ISSUE_DT":"03/11/2026","SIG_SUB":"N","PART_SECTION":"75.333(e)(1)(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/11/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-03-11"}]}],"safety":{"href":"/api/v1/mines/3609394/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609394/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":25,"companyType":"Independent Producer Operator","components":[{"averageEmployees":25,"laborHours":55410,"mineType":"Underground","productionTons":101395}],"county":"Indiana","laborHours":55410,"mineName":"Knob Creek","mineType":"Underground","mshaId":"3609394","operatingAddress":"301 Market Street, Kittanning, PA 16201","operatingCompany":"Rosebud Mining Company","operationType":"Mine only","productionTons":101395,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Pennsylvania (Bituminous)","status":"Active","supplyRegion":"Appalachia Northern","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-8","heading":"Automatic fire sensor and warning device systems; examination and test requirements.","id":"75.1103-8","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-8","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Automatic fire sensor and warning device systems shall be examined at least once each shift when belts are operated as part of a production shift. A functional test of the warning signals shall be made at least once every seven days. Examination and maintenance of such systems shall be by a qualified person.\n\n(b) A record of the functional test conducted in accordance with paragraph (a) of this section shall be maintained by the operator and kept for a period of one year.\n\n(c) Sensors shall be calibrated in accordance with the manufacturer's calibration instructions at intervals not to exceed 31 days. A record of the sensor calibrations shall be maintained by the operator and kept for a period of one year.\n\n[73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 70.209","heading":"Quarterly sampling; designated areas.","id":"70.209","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.209","part":"70","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Sampling Procedures","text":"As of April 14, 2025:\n\n(a) The operator shall sample quarterly each designated area (DA) on consecutive production shifts until five valid representative samples are taken. The quarterly periods are:\n\n(1) January 1-March 31\n\n(2) April 1-June 30\n\n(3) July 1-September 30\n\n(4) October 1-December 31.\n\n(b) [Reserved]\n\n(c) When a valid representative sample taken in accordance with this section meets or exceeds the ECV in table 1 to this section that corresponds to the particular sampling device used, the operator shall:\n\n(1) Make approved respiratory equipment available to affected miners in accordance with § 72.700 of this chapter;\n\n(2) Immediately take corrective action to lower the concentration of respirable dust to at or below the respirable dust standard; and\n\n(3) Make a record of the corrective actions taken. The record shall be certified by the mine foreman or equivalent mine official, no later than the end of the mine foreman's or equivalent official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration. Such records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(d) Noncompliance with the standard is demonstrated during the sampling period when:\n\n(1) Two or more valid representative samples meet or exceed the ECV in table 1 to this section that corresponds to the particular sampling device used; or\n\n(2) The average for all valid representative samples meets or exceeds the ECV in table 1 to this section that corresponds to the particular sampling device used.\n\n(e) Unless otherwise directed by the District Manager, upon issuance of a citation for a violation of the standard, paragraph (a) of this section shall not apply to that DA until the violation is abated and the citation is terminated in accordance with paragraphs (e) and (f) of this section.\n\n(f) Upon issuance of a citation for a violation of the standard, the operator shall take the following actions sequentially:\n\n(1) Make approved respiratory equipment available to affected miners in accordance with § 72.700 of this chapter;\n\n(2) Immediately take corrective action to lower the concentration of respirable coal mine dust to at or below the standard; and\n\n(3) Make a record of the corrective actions taken. The record shall be certified by the mine foreman or equivalent mine official, no later than the end of the mine foreman's or equivalent official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration. Such records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(4) Begin sampling, within 8 calendar days after the date the citation is issued, the environment of the affected DA on consecutive normal production shifts until five valid representative samples are taken.\n\n(g) A citation for a violation of the standard shall be terminated by MSHA when:\n\n(1) Each of the five valid representative samples is at or below the standard; and\n\n(2) The operator has submitted to the District Manager revised dust control parameters as part of the mine ventilation plan applicable to the DA in the citation, and the changes have been approved by the District Manager. The revised parameters shall reflect the control measures used by the operator to abate the violation.\n\nTable 1 to § 70.209—Excessive Concentration Values (ECV) Based on a Single Sample, Two Samples, or the Average of Five or Fifteen Full-Shift CMDPSU/CPDM Concentration Measurements Section Samples ECV (mg/m3) CMDPSU CPDM 70.209 (c) 70.100(a)—Single sample 1.79 1.70 70.100(b)—Single sample 0.74 0.57 70.209(d)(1) 70.100(a)—2 or more samples 1.79 1.70 70.100(b)—2 or more samples 0.74 0.57 70.209(d)(2) 70.100(a)—5 sample average 1.63 1.59 70.100(b)—5 sample average 0.61 0.53 70.209(d)(2) 70.100(a)—15 sample average 1.58 1.56 70.100(b)—15 sample average 0.57 0.52 70.209(g)(1) 70.100(a)—Each of 5 samples 1.79 1.70 70.100(b)—Each of 5 samples 0.74 0.57\n\n[89 FR 28475, 28476, Apr. 18, 2024]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":2},{"chapter":"I","heading":"Welding operations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.408","part":"77","subchapter":"O","subpart":"E","id":"77.408","citation":"30 CFR 77.408","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609394","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}