{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"3609287","name":"LOWRY MINE","status":"Active","status_date":"2020-12-07","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Indiana","nearest_town":"Lucerne","operator_id":"P09635","operator_name":"ROSEBUD MINING COMPANY","controller_id":"C07485","controller_name":"J Clifford  Forrest III","district":"C03","office":"Indiana PA Field Office","employees":35,"latitude":40.571667,"longitude":-79.123333},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":5078},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609287","name":"LOWRY MINE"},"operator":{"type":"operator","id":"P09635","name":"ROSEBUD MINING COMPANY"},"controller":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"mine","id":"3609287","name":"LOWRY MINE"},"validFrom":"1979-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609287|C07485|1979-08-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"object":{"type":"mine","id":"3609287","name":"LOWRY MINE"},"validFrom":"2005-01-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609287|P09635|2005-01-25|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"validFrom":"2005-01-25","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609287","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609287|P09635|2005-01-25|C07485|1979-08-01|74824"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":32,"firstDate":"2008-08-04","lastDate":"2025-09-18","metrics":{"daysLost":1059,"injuries":27,"fatalities":0,"recentRows":11,"restrictedDays":124,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"131659","DOCUMENT_NO":"220252680007","ACCIDENT_DT":"09/18/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"The scoop guy was pushing a skid in to the belt line. The skid caught a roll of belt pushing it sideways into the employee who was in a crosscut, bruising EE's hip.","sourceDate":"2025-09-18"},{"SOURCE_ROW_NUMBER":"191948","DOCUMENT_NO":"220250700025","ACCIDENT_DT":"02/12/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"58","NARRATIVE":"EE was exiting a scoop and twisted knee. EE was excused from work on 3/11/2025, and will be getting meniscus repaired in right knee.","sourceDate":"2025-02-12"},{"SOURCE_ROW_NUMBER":"170603","DOCUMENT_NO":"220243580007","ACCIDENT_DT":"12/05/2024","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Forklift operator","NO_INJURIES":"1","DAYS_LOST":"37","NARRATIVE":"EE slipped on ice getting out of EE's vehicle and hit EE's head. This resulted in a concussion. EE was excused from work 12/10/2024.","sourceDate":"2024-12-05"},{"SOURCE_ROW_NUMBER":"84570","DOCUMENT_NO":"220243260017","ACCIDENT_DT":"11/19/2024","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While installing a bolt, EE pinched pinky finger between the plate and drill head. Which resulted in stitches.","sourceDate":"2024-11-19"},{"SOURCE_ROW_NUMBER":"32955","DOCUMENT_NO":"220243090016","ACCIDENT_DT":"10/28/2024","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"74","NARRATIVE":"EE was trying to remove pin from the low-tail, when the tail moved back. EE's finger got pinched between the pin and the top surface of the tail. Which resulted in stitches.","sourceDate":"2024-10-28"},{"SOURCE_ROW_NUMBER":"191947","DOCUMENT_NO":"220240030025","ACCIDENT_DT":"10/19/2023","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"66","NARRATIVE":"EE was spotting low structure and strained shoulder, resulting in a lost time accident as of 12/28/2023.","sourceDate":"2023-10-19"},{"SOURCE_ROW_NUMBER":"222160","DOCUMENT_NO":"220232440012","ACCIDENT_DT":"08/21/2023","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Individual was trying to straighten a top slide when it slid off of the structure and the individual struck hand on the rail. This resulted in a fractured hand.","sourceDate":"2023-08-21"},{"SOURCE_ROW_NUMBER":"140447","DOCUMENT_NO":"220230120008","ACCIDENT_DT":"01/09/2023","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"38","NARRATIVE":"Pinched their hand between drill head and roof, which resulted in stitches","sourceDate":"2023-01-09"},{"SOURCE_ROW_NUMBER":"183499","DOCUMENT_NO":"220222940007","ACCIDENT_DT":"10/20/2022","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was backing up the mobile, and pulled themselves up in the seat, at the same time the mbc went over a hump, pushing their head down. Which caused their chin to hit off the guard above the levers. This resulted in stitches.","sourceDate":"2022-10-20"},{"SOURCE_ROW_NUMBER":"200557","DOCUMENT_NO":"220211190019","ACCIDENT_DT":"04/28/2021","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was removing a rock from the conveyor, when it dislodged and pinched EE's finger between the rock and coal chain, causing a fracture.","sourceDate":"2021-04-28"},{"SOURCE_ROW_NUMBER":"62930","DOCUMENT_NO":"220211190009","ACCIDENT_DT":"04/21/2021","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"22","NARRATIVE":"Was backing up miner for the day, the employee shut the machine off. Crawled under the bridge and it teetered and pinched their hip, causing a dislocation.","sourceDate":"2021-04-21"},{"SOURCE_ROW_NUMBER":"24374","DOCUMENT_NO":"220200590026","ACCIDENT_DT":"01/24/2020","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"356","NARRATIVE":"While lifting low belt to remove a bottom stand, felt a strain in back, which became a lost time accident 02/20/2020.","sourceDate":"2020-01-24"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2020-12-07","lastDate":"2020-12-07","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":671,"firstDate":"2008-08-05","lastDate":"2026-08-25","metrics":{"ss":168,"delinquent":646,"recentRows":169,"paidPenalty":212927.3,"proposedPenalty":272904,"currentAssessment":213229.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3043039","VIOLATION_NO":"5153505","ISSUE_DT":"08/25/2026","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"3043037","VIOLATION_NO":"5153503","ISSUE_DT":"08/17/2026","CFR_STANDARD_CD":"75.208","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"1668294","VIOLATION_NO":"5153175","ISSUE_DT":"07/27/2026","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1667724","VIOLATION_NO":"9607345","ISSUE_DT":"07/27/2026","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"168.00","CURRENT_ASSESSMENT_AMT":"168.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1667723","VIOLATION_NO":"9607344","ISSUE_DT":"07/27/2026","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1668293","VIOLATION_NO":"5153174","ISSUE_DT":"07/23/2026","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"3043034","VIOLATION_NO":"9603596","ISSUE_DT":"07/07/2026","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-07-07"},{"SOURCE_ROW_NUMBER":"1668283","VIOLATION_NO":"5153171","ISSUE_DT":"06/05/2026","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-06-05"},{"SOURCE_ROW_NUMBER":"1668285","VIOLATION_NO":"5153169","ISSUE_DT":"05/12/2026","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"336.00","CURRENT_ASSESSMENT_AMT":"336.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-05-12"},{"SOURCE_ROW_NUMBER":"1668284","VIOLATION_NO":"5153168","ISSUE_DT":"05/12/2026","CFR_STANDARD_CD":"75.1103-4(a)(1)(iv)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-05-12"},{"SOURCE_ROW_NUMBER":"1668282","VIOLATION_NO":"5153167","ISSUE_DT":"05/11/2026","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-05-11"},{"SOURCE_ROW_NUMBER":"3037927","VIOLATION_NO":"9603591","ISSUE_DT":"04/28/2026","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-04-28"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":191,"firstDate":"2009-04-06","lastDate":"2025-05-12","metrics":{"appeals":0,"decisions":191,"recentRows":9,"decisionPenalty":122504.3,"originalPenalty":185916},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"218817","VIOLATION_NO":"9208341","DOCKET_NO":"PENN 2025-0071","DECISION_DT":"05/12/2025","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"1773.00","DECISION_PENALTY_AMT":"1773.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2025-05-12"},{"SOURCE_ROW_NUMBER":"459745","VIOLATION_NO":"9208330","DOCKET_NO":"PENN 2025-0055","DECISION_DT":"05/05/2025","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"221.00","DECISION_PENALTY_AMT":"221.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2025-05-05"},{"SOURCE_ROW_NUMBER":"218951","VIOLATION_NO":"9208925","DOCKET_NO":"PENN 2025-0055","DECISION_DT":"05/05/2025","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"736.00","DECISION_PENALTY_AMT":"736.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Young","sourceDate":"2025-05-05"},{"SOURCE_ROW_NUMBER":"207872","VIOLATION_NO":"9201324","DOCKET_NO":"PENN 2023-0065","DECISION_DT":"07/20/2023","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"143.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Sullivan","sourceDate":"2023-07-20"},{"SOURCE_ROW_NUMBER":"438223","VIOLATION_NO":"9201198","DOCKET_NO":"PENN 2021-0049","DECISION_DT":"07/02/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"257.00","DECISION_PENALTY_AMT":"257.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2021-07-02"},{"SOURCE_ROW_NUMBER":"437080","VIOLATION_NO":"9072155","DOCKET_NO":"PENN 2021-0014","DECISION_DT":"02/26/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"123.00","DECISION_PENALTY_AMT":"123.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2021-02-26"},{"SOURCE_ROW_NUMBER":"436926","VIOLATION_NO":"9078658","DOCKET_NO":"PENN 2021-0014","DECISION_DT":"02/26/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"720.00","DECISION_PENALTY_AMT":"146.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2021-02-26"},{"SOURCE_ROW_NUMBER":"436786","VIOLATION_NO":"9073448","DOCKET_NO":"PENN 2021-0009","DECISION_DT":"02/23/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"523.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"435702","VIOLATION_NO":"9078653","DOCKET_NO":"PENN 2021-0009","DECISION_DT":"02/23/2021","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1166.00","DECISION_PENALTY_AMT":"235.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2021-02-23"},{"SOURCE_ROW_NUMBER":"431640","VIOLATION_NO":"9078261","DOCKET_NO":"PENN 2020-0025","DECISION_DT":"03/16/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2020-03-16"},{"SOURCE_ROW_NUMBER":"431177","VIOLATION_NO":"9078257","DOCKET_NO":"PENN 2020-0025","DECISION_DT":"03/16/2020","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2020-03-16"},{"SOURCE_ROW_NUMBER":"403227","VIOLATION_NO":"9073199","DOCKET_NO":"PENN 2016-0199","DECISION_DT":"08/04/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"253.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2016-08-04"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":2277,"firstDate":"2008-01-15","lastDate":"2026-10-15","metrics":{"recentRows":1245,"cpdmSamples":1340,"voidSamples":393,"validSamples":1884,"maxConcentration":63.025,"concentrationTotal":1364.155},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2861897","SMP_TAKEN_DT":"10/15/2026","CONC":".792","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-15"},{"SOURCE_ROW_NUMBER":"2862432","SMP_TAKEN_DT":"10/14/2026","CONC":".688","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2178266","SMP_TAKEN_DT":"10/14/2026","CONC":".826","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"2691287","SMP_TAKEN_DT":"10/13/2026","CONC":"1.006","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"2605193","SMP_TAKEN_DT":"10/13/2026","CONC":".458","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-13"},{"SOURCE_ROW_NUMBER":"3032849","SMP_TAKEN_DT":"10/12/2026","CONC":".894","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-12"},{"SOURCE_ROW_NUMBER":"2178148","SMP_TAKEN_DT":"10/12/2026","CONC":".555","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-12"},{"SOURCE_ROW_NUMBER":"2861770","SMP_TAKEN_DT":"10/9/2026","CONC":".873","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-09"},{"SOURCE_ROW_NUMBER":"2092428","SMP_TAKEN_DT":"10/9/2026","CONC":"1.21","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-09"},{"SOURCE_ROW_NUMBER":"3031976","SMP_TAKEN_DT":"10/8/2026","CONC":".872","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"1751208","SMP_TAKEN_DT":"10/8/2026","CONC":".503","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-08"},{"SOURCE_ROW_NUMBER":"3032989","SMP_TAKEN_DT":"10/7/2026","CONC":".727","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2026-10-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":20,"firstDate":"2011-02-10","lastDate":"2013-04-16","metrics":{"linkedIssuances":20},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":191,"firstDate":"2008-08-05","lastDate":"2024-12-10","metrics":{"decisions":191,"ssChanged":58,"recentRows":5,"decisionPenalty":122504.3,"proposedPenalty":185916},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"391415","CITATION_NO":"9208341","CITATION_ISSUE_DT":"12/10/2024","DOCKET_NO":"PENN 2025-0071","DECISION_DT":"05/12/2025","CFR_STANDARD_CODE":"75.1103-5(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1773.00","DECISION_PENALTY_AMT":"1773.00","sourceDate":"2024-12-10"},{"SOURCE_ROW_NUMBER":"167191","CITATION_NO":"9208330","CITATION_ISSUE_DT":"10/04/2024","DOCKET_NO":"PENN 2025-0055","DECISION_DT":"05/05/2025","CFR_STANDARD_CODE":"75.523-3(b)(1)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"221.00","DECISION_PENALTY_AMT":"221.00","sourceDate":"2024-10-04"},{"SOURCE_ROW_NUMBER":"166233","CITATION_NO":"9208925","CITATION_ISSUE_DT":"10/02/2024","DOCKET_NO":"PENN 2025-0055","DECISION_DT":"05/05/2025","CFR_STANDARD_CODE":"75.208","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"736.00","DECISION_PENALTY_AMT":"736.00","sourceDate":"2024-10-02"},{"SOURCE_ROW_NUMBER":"50600","CITATION_NO":"9201324","CITATION_ISSUE_DT":"01/24/2023","DOCKET_NO":"PENN 2023-0065","DECISION_DT":"07/20/2023","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"143.00","sourceDate":"2023-01-24"},{"SOURCE_ROW_NUMBER":"274551","CITATION_NO":"9201198","CITATION_ISSUE_DT":"01/11/2021","DOCKET_NO":"PENN 2021-0049","DECISION_DT":"07/02/2021","CFR_STANDARD_CODE":"75.1722(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"257.00","DECISION_PENALTY_AMT":"257.00","sourceDate":"2021-01-11"},{"SOURCE_ROW_NUMBER":"388009","CITATION_NO":"9078658","CITATION_ISSUE_DT":"09/01/2020","DOCKET_NO":"PENN 2021-0014","DECISION_DT":"02/26/2021","CFR_STANDARD_CODE":"75.1725(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"720.00","DECISION_PENALTY_AMT":"146.00","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"105468","CITATION_NO":"9072155","CITATION_ISSUE_DT":"09/01/2020","DOCKET_NO":"PENN 2021-0014","DECISION_DT":"02/26/2021","CFR_STANDARD_CODE":"75.330(b)(1)(i)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"123.00","DECISION_PENALTY_AMT":"123.00","sourceDate":"2020-09-01"},{"SOURCE_ROW_NUMBER":"162321","CITATION_NO":"9073448","CITATION_ISSUE_DT":"08/06/2020","DOCKET_NO":"PENN 2021-0009","DECISION_DT":"02/23/2021","CFR_STANDARD_CODE":"75.326","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"523.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2020-08-06"},{"SOURCE_ROW_NUMBER":"158267","CITATION_NO":"9078653","CITATION_ISSUE_DT":"07/20/2020","DOCKET_NO":"PENN 2021-0009","DECISION_DT":"02/23/2021","CFR_STANDARD_CODE":"75.1103-1","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1166.00","DECISION_PENALTY_AMT":"235.00","sourceDate":"2020-07-20"},{"SOURCE_ROW_NUMBER":"385777","CITATION_NO":"9078261","CITATION_ISSUE_DT":"09/05/2019","DOCKET_NO":"PENN 2020-0025","DECISION_DT":"03/16/2020","CFR_STANDARD_CODE":"70.212(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-05"},{"SOURCE_ROW_NUMBER":"445454","CITATION_NO":"9078257","CITATION_ISSUE_DT":"08/27/2019","DOCKET_NO":"PENN 2020-0025","DECISION_DT":"03/16/2020","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":".00","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"434385","CITATION_NO":"7031764","CITATION_ISSUE_DT":"10/20/2015","DOCKET_NO":"PENN 2016-0098","DECISION_DT":"06/24/2016","CFR_STANDARD_CODE":"77.205(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"114.00","sourceDate":"2015-10-20"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":15,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2005-01-25","lastDate":"2005-01-25","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":643,"firstDate":"2008-01-10","lastDate":"2026-10-15","metrics":{"inspectors":863,"recentRows":259,"onSiteHours":12520.75,"inspectionHours":17680.5,"inspectionSamples":1872},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1150016","EVENT_NO":"F047535","INSPECTION_BEGIN_DT":"10/15/2026","INSPECTION_END_DT":"10/15/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2026-10-15"},{"SOURCE_ROW_NUMBER":"377328","EVENT_NO":"F04752F","INSPECTION_BEGIN_DT":"10/06/2026","INSPECTION_END_DT":"10/06/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-10-06"},{"SOURCE_ROW_NUMBER":"1092517","EVENT_NO":"F03EB86","INSPECTION_BEGIN_DT":"10/05/2026","INSPECTION_END_DT":"10/05/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"833249","EVENT_NO":"F02DA4A","INSPECTION_BEGIN_DT":"10/01/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"53","SUM_TOTAL_ON_SITE_HOURS":"40.75","sourceDate":"2026-10-01"},{"SOURCE_ROW_NUMBER":"90148","EVENT_NO":"6245854","INSPECTION_BEGIN_DT":"09/24/2026","INSPECTION_END_DT":"09/24/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2026-09-24"},{"SOURCE_ROW_NUMBER":"43405","EVENT_NO":"F04752A","INSPECTION_BEGIN_DT":"09/21/2026","INSPECTION_END_DT":"09/21/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-09-21"},{"SOURCE_ROW_NUMBER":"1118075","EVENT_NO":"F00BB76","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/10/2026","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"397662","EVENT_NO":"F047525","INSPECTION_BEGIN_DT":"09/08/2026","INSPECTION_END_DT":"09/08/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-09-08"},{"SOURCE_ROW_NUMBER":"1030819","EVENT_NO":"F028F8D","INSPECTION_BEGIN_DT":"08/27/2026","INSPECTION_END_DT":"08/27/2026","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"1088681","EVENT_NO":"F047521","INSPECTION_BEGIN_DT":"08/25/2026","INSPECTION_END_DT":"08/25/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"298311","EVENT_NO":"F04751E","INSPECTION_BEGIN_DT":"08/17/2026","INSPECTION_END_DT":"08/17/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"112230","EVENT_NO":"F047519","INSPECTION_BEGIN_DT":"08/04/2026","INSPECTION_END_DT":"08/04/2026","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2026-08-04"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":38,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017":{"hours":11670,"employees":8,"production":20752},"2018":{"hours":7078,"employees":7,"production":12894},"2019":{"hours":24005,"employees":11,"production":75872},"2020":{"hours":27782,"employees":15,"production":72632},"2021":{"hours":44568,"employees":17,"production":117436},"2022":{"hours":51072,"employees":24,"production":140824},"2023":{"hours":55733,"employees":21,"production":174879},"2024":{"hours":50806,"employees":21,"production":135717},"2025":{"hours":56101,"employees":23,"production":98332},"2026":{"hours":40732,"employees":34,"production":122368}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":170,"firstDate":"2008-01-22","lastDate":"2026-08-27","metrics":{"recentRows":54,"doseOver100":19,"actDoseTotal":9720,"pelDoseTotal":6541},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"170539","EVENT_NO":"F028F8D","SURVEY_DATE":"08/27/2026","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","ACT_DOSE_85":"75","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2026-08-27"},{"SOURCE_ROW_NUMBER":"170537","EVENT_NO":"6245850","SURVEY_DATE":"07/20/2026","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","ACT_DOSE_85":"1","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"170536","EVENT_NO":"6245850","SURVEY_DATE":"07/20/2026","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","ACT_DOSE_85":"10","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"170535","EVENT_NO":"6245850","SURVEY_DATE":"07/20/2026","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"20","ACT_DOSE_85":"4","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2026-07-20"},{"SOURCE_ROW_NUMBER":"170526","EVENT_NO":"6245540","SURVEY_DATE":"03/24/2026","OCCUPATION_CD_DESC":"SCOOP OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"33","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-03-24"},{"SOURCE_ROW_NUMBER":"170534","EVENT_NO":"6245794","SURVEY_DATE":"03/12/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"60","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"170533","EVENT_NO":"6245794","SURVEY_DATE":"03/12/2026","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","ACT_DOSE_85":"50","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"170532","EVENT_NO":"6245794","SURVEY_DATE":"03/12/2026","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","ACT_DOSE_85":"30","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"170531","EVENT_NO":"6245794","SURVEY_DATE":"03/12/2026","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","ACT_DOSE_85":"32","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"170530","EVENT_NO":"6245794","SURVEY_DATE":"03/12/2026","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","ACT_DOSE_85":"102","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"170529","EVENT_NO":"6245794","SURVEY_DATE":"03/12/2026","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","ACT_DOSE_85":"39","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"170528","EVENT_NO":"6245794","SURVEY_DATE":"02/13/2026","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2026-02-13"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":139,"firstDate":"2008-09-10","lastDate":"2026-10-05","metrics":{"recentRows":82,"voidSamples":4,"maxQuartzPct":7.3,"validSamples":135,"quartzPctTotal":274.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"166052","CASSETTE_NO":"58601253","SAMPLE_DT":"10/05/2026","QUARTZ_PCT":"04.1","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"79276","CASSETTE_NO":"58601291","SAMPLE_DT":"10/05/2026","QUARTZ_PCT":"00.9","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"119552","CASSETTE_NO":"58601059","SAMPLE_DT":"07/23/2026","QUARTZ_PCT":"01.3","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"100039","CASSETTE_NO":"58600789","SAMPLE_DT":"07/23/2026","QUARTZ_PCT":"00.6","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"80595","CASSETTE_NO":"58600838","SAMPLE_DT":"07/23/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"31442","CASSETTE_NO":"58597676","SAMPLE_DT":"05/27/2026","QUARTZ_PCT":"01.5","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"CONTROL FILTER INVALID","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"18956","CASSETTE_NO":"58597405","SAMPLE_DT":"05/27/2026","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-05-27"},{"SOURCE_ROW_NUMBER":"167580","CASSETTE_NO":"58565034","SAMPLE_DT":"02/03/2026","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-03"},{"SOURCE_ROW_NUMBER":"166675","CASSETTE_NO":"58565201","SAMPLE_DT":"02/03/2026","QUARTZ_PCT":"01.5","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-03"},{"SOURCE_ROW_NUMBER":"140208","CASSETTE_NO":"58565094","SAMPLE_DT":"02/03/2026","QUARTZ_PCT":"00.7","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2026-02-03"},{"SOURCE_ROW_NUMBER":"31868","CASSETTE_NO":"58564704","SAMPLE_DT":"12/17/2025","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-12-17"},{"SOURCE_ROW_NUMBER":"3712","CASSETTE_NO":"58564986","SAMPLE_DT":"12/17/2025","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2025-12-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":682,"firstDate":"2008-08-05","lastDate":"2026-10-14","metrics":{"ss":168,"amountDue":213229.3,"contested":70,"amountPaid":212927.3,"recentRows":174,"section104d":1,"unterminated":0,"proposedPenalty":272904},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1977907","VIOLATION_NO":"9607449","VIOLATION_ISSUE_DT":"10/14/2026","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/14/2026","CONTESTED_IND":"N","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"1977906","VIOLATION_NO":"9607448","VIOLATION_ISSUE_DT":"10/14/2026","SIG_SUB":"N","PART_SECTION":"75.333(e)(1)(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/14/2026","CONTESTED_IND":"N","sourceDate":"2026-10-14"},{"SOURCE_ROW_NUMBER":"1978000","VIOLATION_NO":"9605370","VIOLATION_ISSUE_DT":"10/05/2026","SIG_SUB":"N","PART_SECTION":"75.809","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/05/2026","CONTESTED_IND":"N","sourceDate":"2026-10-05"},{"SOURCE_ROW_NUMBER":"1977848","VIOLATION_NO":"5153505","VIOLATION_ISSUE_DT":"08/25/2026","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/25/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-25"},{"SOURCE_ROW_NUMBER":"1977845","VIOLATION_NO":"5153503","VIOLATION_ISSUE_DT":"08/17/2026","SIG_SUB":"N","PART_SECTION":"75.208","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/17/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-08-17"},{"SOURCE_ROW_NUMBER":"1977827","VIOLATION_NO":"9607345","VIOLATION_ISSUE_DT":"07/27/2026","SIG_SUB":"N","SECTION_OF_ACT":"316(b)(2)(A)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/27/2026","PROPOSED_PENALTY":"168","AMOUNT_DUE":"168","AMOUNT_PAID":"168","CONTESTED_IND":"N","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1977826","VIOLATION_NO":"9607344","VIOLATION_ISSUE_DT":"07/27/2026","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1977794","VIOLATION_NO":"5153175","VIOLATION_ISSUE_DT":"07/27/2026","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/27/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-27"},{"SOURCE_ROW_NUMBER":"1977793","VIOLATION_NO":"5153174","VIOLATION_ISSUE_DT":"07/23/2026","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/23/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-23"},{"SOURCE_ROW_NUMBER":"1977795","VIOLATION_NO":"9603596","VIOLATION_ISSUE_DT":"07/07/2026","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/07/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-07-07"},{"SOURCE_ROW_NUMBER":"1977606","VIOLATION_NO":"5153171","VIOLATION_ISSUE_DT":"06/05/2026","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/08/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-06-05"},{"SOURCE_ROW_NUMBER":"1977670","VIOLATION_NO":"5153169","VIOLATION_ISSUE_DT":"05/12/2026","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/13/2026","PROPOSED_PENALTY":"336","AMOUNT_DUE":"336","AMOUNT_PAID":"336","CONTESTED_IND":"N","sourceDate":"2026-05-12"}]}],"safety":{"href":"/api/v1/mines/3609287/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609287/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":{"averageEmployees":22,"companyType":"Independent Producer Operator","components":[{"averageEmployees":22,"laborHours":50806,"mineType":"Underground","productionTons":135717}],"county":"Indiana","laborHours":50806,"mineName":"Lowry Mine","mineType":"Underground","mshaId":"3609287","operatingAddress":"301 Market Street, Kittanning, PA 16201","operatingCompany":"Rosebud Mining Company","operationType":"Mine only","productionTons":135717,"reportedRows":1,"sourceUrl":"https://www.eia.gov/coal/data/public/xls/coalpublic2024.xlsx","state":"Pennsylvania (Bituminous)","status":"Active","supplyRegion":"Appalachia Northern","union":"","year":2024},"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Identification of circuit breakers and disconnecting switches.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.809","part":"75","subchapter":"O","subpart":"I","id":"75.809","citation":"30 CFR 75.809","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.208","part":"75","subchapter":"O","subpart":"C","id":"75.208","citation":"30 CFR 75.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609287","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}