{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"3609159","name":"T.J.S. No. 5 Mine","status":"Abandoned and Sealed","status_date":"2009-09-22","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Armstrong","nearest_town":"Spring Church","operator_id":"P21491","operator_name":"T.J.S. Mining, Inc.","controller_id":"C13674","controller_name":"Thomas J  Smith","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":40.694166,"longitude":-79.372777},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":708},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609159","name":"T.J.S. No. 5 Mine"},"operator":{"type":"operator","id":"P21491","name":"T.J.S. Mining, Inc."},"controller":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"object":{"type":"mine","id":"3609159","name":"T.J.S. No. 5 Mine"},"validFrom":"1991-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609159|C13674|1991-05-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21491","name":"T.J.S. Mining, Inc."},"object":{"type":"mine","id":"3609159","name":"T.J.S. No. 5 Mine"},"validFrom":"2003-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609159|P21491|2003-08-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"object":{"type":"operator","id":"P21491","name":"T.J.S. Mining, Inc."},"validFrom":"2003-08-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609159","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3609159|P21491|2003-08-01|C13674|1991-05-01|90815"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":47,"firstDate":"2005-02-04","lastDate":"2008-10-17","metrics":{"daysLost":376,"injuries":22,"fatalities":0,"recentRows":0,"restrictedDays":113,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"11453","DOCUMENT_NO":"220083010006","ACCIDENT_DT":"10/17/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"17","NARRATIVE":"Employee was directing the fork lift operator on changing batteries on scoop.  He directed the fork lift operator to set batteries down; at the same time he reached for cap on battery jack on scoop.  He got left thumb pinched between cap of jack and battery.","sourceDate":"2008-10-17"},{"SOURCE_ROW_NUMBER":"209246","DOCUMENT_NO":"220082880008","ACCIDENT_DT":"10/02/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unplanned roof fall occurred in the #3 entry of 1 Right, 1 x-cut inby survey station #683. Fall was approximately 4' plus high, 19' wide, and 35' long.  Area was timbered and dangered off.  Did not affect any ventilation but did cover about 35' of belt and structure.  Will not be cleaned up.  Area was bolted with 4' compression bolts  and was also center posted.","sourceDate":"2008-10-02"},{"SOURCE_ROW_NUMBER":"54349","DOCUMENT_NO":"220082740049","ACCIDENT_DT":"09/17/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unplanned roof fall was found in the #2 entry 1 x-cut outby survey station #996 fall was approx. 30' long, 30; wide and 6' plus high. Fall did not affect any ventilation or equipment, roof fall will not be cleaned up, area was timbered and dangered off.","sourceDate":"2008-09-17"},{"SOURCE_ROW_NUMBER":"239438","DOCUMENT_NO":"220082560020","ACCIDENT_DT":"09/04/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"An unplanned roof fall occurred in the belt entry (#3) 1 x-cut outby survey station #8.  Fall was approximately ten (10') high, nineteen (19') wide and thirty five to forty feet (35' to 40') long.  Area was bolted with four (4') fully grouted bolts with x-bars installed as per our approved initial roof control plan.  Fall will be cleaned up.  Did not affect any ventilation.","sourceDate":"2008-09-04"},{"SOURCE_ROW_NUMBER":"75939","DOCUMENT_NO":"220082260021","ACCIDENT_DT":"08/04/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was attempting to punch a hole in a piece of belt for a date board when the employee swung the hammer to strike punch and missed striking his left hand. The employee did not miss any work however he received four (4) sutures thus making this accident report a medical.","sourceDate":"2008-08-04"},{"SOURCE_ROW_NUMBER":"54348","DOCUMENT_NO":"220081910002","ACCIDENT_DT":"07/02/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"Employee had lowered the head of the roof bolter to remove drill steels.  The finisher steel had stuck in the roof.  As the employee was putting the pusher steel away, the finisher steel fell out of the roof, striking the employee on the ring finger of his left hand.","sourceDate":"2008-07-02"},{"SOURCE_ROW_NUMBER":"140440","DOCUMENT_NO":"220080220010","ACCIDENT_DT":"01/08/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was backing a personnel carrier up when his hard hat caught on a roof bolt thus pushing his hard hat down onto forehead causing a laceration.  Employee did not miss any work, however he did receive eight (8) sutures therefore making this report a medical.","sourceDate":"2008-01-08"},{"SOURCE_ROW_NUMBER":"37244","DOCUMENT_NO":"220073380031","ACCIDENT_DT":"11/21/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee pinched hand between the head of roof bolter and roof bolt plate. He missed one (1) day due to this injury. This occurred over the Thanksgiving/deer season holiday of which we were idle.  We returned back to work on November 28, 2007.  His day missed was on Friday, November 23, 2007 only.","sourceDate":"2007-11-21"},{"SOURCE_ROW_NUMBER":"222154","DOCUMENT_NO":"220073520048","ACCIDENT_DT":"11/19/2007","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee twisted lower back while setting fibercribs.  Employee did not miss any work however after seeking treatment for ongoing pain the physician placed him on restricted duty effective 12/12/2007 now making this report classified as a medical.","sourceDate":"2007-11-19"},{"SOURCE_ROW_NUMBER":"93003","DOCUMENT_NO":"220073130004","ACCIDENT_DT":"11/02/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating scoop, when he ran over a hump on the roadway, thus causing him to strike his head against a roof bolt and caused a laceration.  Employee did not miss any work, however he did receive sutures, making this a medical report.","sourceDate":"2007-11-02"},{"SOURCE_ROW_NUMBER":"273753","DOCUMENT_NO":"220073030007","ACCIDENT_DT":"10/24/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"Employee was servicing his front end loader when he slipped and fell to the ground injuring his lower back and groin area.","sourceDate":"2007-10-24"},{"SOURCE_ROW_NUMBER":"54347","DOCUMENT_NO":"220080650035","ACCIDENT_DT":"09/14/2007","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Draftsman, Surveyor/Transit work supervisor","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"Employee was running levels.  After doing surveying the employee started to duck walk due to sore shoulders when his right knee popped and partially locked up. Employee continued working until February 28, 2008 at which time surgery was performed to repair a meniscus tear of the right knee now making this a reportable.","sourceDate":"2007-09-14"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-09-22","lastDate":"2009-09-22","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":154,"firstDate":"2004-12-29","lastDate":"2009-03-18","metrics":{"ss":70,"delinquent":150,"recentRows":0,"paidPenalty":52257,"proposedPenalty":52257,"currentAssessment":52257},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1655436","VIOLATION_NO":"7061342","ISSUE_DT":"03/18/2009","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-03-18"},{"SOURCE_ROW_NUMBER":"1655435","VIOLATION_NO":"7061341","ISSUE_DT":"03/18/2009","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-03-18"},{"SOURCE_ROW_NUMBER":"665981","VIOLATION_NO":"7060620","ISSUE_DT":"10/03/2008","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-03"},{"SOURCE_ROW_NUMBER":"663915","VIOLATION_NO":"7061316","ISSUE_DT":"10/02/2008","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1657.00","CURRENT_ASSESSMENT_AMT":"1657.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-02"},{"SOURCE_ROW_NUMBER":"665851","VIOLATION_NO":"7054702","ISSUE_DT":"09/18/2008","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-18"},{"SOURCE_ROW_NUMBER":"665850","VIOLATION_NO":"7019383","ISSUE_DT":"09/11/2008","CFR_STANDARD_CD":"75.340(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-11"},{"SOURCE_ROW_NUMBER":"665849","VIOLATION_NO":"7019382","ISSUE_DT":"09/09/2008","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"3143.00","CURRENT_ASSESSMENT_AMT":"3143.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-09"},{"SOURCE_ROW_NUMBER":"665848","VIOLATION_NO":"7019381","ISSUE_DT":"09/09/2008","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"1111.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-09"},{"SOURCE_ROW_NUMBER":"665847","VIOLATION_NO":"7019380","ISSUE_DT":"09/08/2008","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"665846","VIOLATION_NO":"7019379","ISSUE_DT":"09/08/2008","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"1111.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"665845","VIOLATION_NO":"7019378","ISSUE_DT":"09/04/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-04"},{"SOURCE_ROW_NUMBER":"665844","VIOLATION_NO":"7019377","ISSUE_DT":"09/04/2008","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"1111.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-09-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2010-12-17","lastDate":"2010-12-17","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":1657,"originalPenalty":1657},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"16034","VIOLATION_NO":"7063809","DOCKET_NO":"PENN 2008-376","DECISION_DT":"12/17/2010","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1657.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-12-17"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":230,"firstDate":"2005-03-23","lastDate":"2008-09-24","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":222,"maxConcentration":8.928,"concentrationTotal":161.567},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1368397","CASS_NUM":"57694304","SMP_TAKEN_DT":"9/24/2008","CONC":".415","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-24"},{"SOURCE_ROW_NUMBER":"1237010","CASS_NUM":"57694351","SMP_TAKEN_DT":"9/24/2008","CONC":".556","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-24"},{"SOURCE_ROW_NUMBER":"1004614","CASS_NUM":"57694315","SMP_TAKEN_DT":"9/24/2008","CONC":".498","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-24"},{"SOURCE_ROW_NUMBER":"493733","CASS_NUM":"57694314","SMP_TAKEN_DT":"9/24/2008","CONC":".287","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-24"},{"SOURCE_ROW_NUMBER":"447016","CASS_NUM":"57694357","SMP_TAKEN_DT":"9/24/2008","CONC":"1.082","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-24"},{"SOURCE_ROW_NUMBER":"172065","CASS_NUM":"57694310","SMP_TAKEN_DT":"9/24/2008","CONC":".081","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-24"},{"SOURCE_ROW_NUMBER":"1279357","CASS_NUM":"50939832","SMP_TAKEN_DT":"9/17/2008","CONC":".28","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-17"},{"SOURCE_ROW_NUMBER":"1263543","CASS_NUM":"57728280","SMP_TAKEN_DT":"9/17/2008","CONC":".094","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"FORKLIFT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-17"},{"SOURCE_ROW_NUMBER":"1204746","CASS_NUM":"50939825","SMP_TAKEN_DT":"9/17/2008","CONC":".106","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-17"},{"SOURCE_ROW_NUMBER":"1153422","CASS_NUM":"57728369","SMP_TAKEN_DT":"9/17/2008","CONC":".248","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"FORKLIFT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-17"},{"SOURCE_ROW_NUMBER":"239924","CASS_NUM":"57728302","SMP_TAKEN_DT":"9/17/2008","CONC":".031","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-17"},{"SOURCE_ROW_NUMBER":"1084337","CASS_NUM":"50939852","SMP_TAKEN_DT":"9/16/2008","CONC":".076","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-09-16"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2008-03-21","lastDate":"2008-03-21","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2007-05-01","lastDate":"2007-05-01","metrics":{"decisions":1,"ssChanged":1,"recentRows":0,"decisionPenalty":1657,"proposedPenalty":1657},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"118311","CITATION_NO":"7063809","CITATION_ISSUE_DT":"05/01/2007","DOCKET_NO":"PENN 2008-376","DECISION_DT":"12/17/2010","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1657.00","sourceDate":"2007-05-01"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2003-08-01","lastDate":"2003-08-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":63,"firstDate":"2004-09-28","lastDate":"2009-07-22","metrics":{"inspectors":113,"recentRows":0,"onSiteHours":1842.75,"inspectionHours":3195.5,"inspectionSamples":166},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1000543","EVENT_NO":"6230307","INSPECTION_BEGIN_DT":"07/22/2009","INSPECTION_END_DT":"09/22/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"639419","EVENT_NO":"6230273","INSPECTION_BEGIN_DT":"05/14/2009","INSPECTION_END_DT":"05/18/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2009-05-14"},{"SOURCE_ROW_NUMBER":"338295","EVENT_NO":"6230302","INSPECTION_BEGIN_DT":"03/18/2009","INSPECTION_END_DT":"03/27/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2009-03-18"},{"SOURCE_ROW_NUMBER":"634112","EVENT_NO":"6230253","INSPECTION_BEGIN_DT":"11/24/2008","INSPECTION_END_DT":"12/16/2008","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2008-11-24"},{"SOURCE_ROW_NUMBER":"388554","EVENT_NO":"4016584","INSPECTION_BEGIN_DT":"10/23/2008","INSPECTION_END_DT":"10/23/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"269309","EVENT_NO":"4018411","INSPECTION_BEGIN_DT":"10/02/2008","INSPECTION_END_DT":"10/10/2008","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2008-10-02"},{"SOURCE_ROW_NUMBER":"114649","EVENT_NO":"4019728","INSPECTION_BEGIN_DT":"10/02/2008","INSPECTION_END_DT":"11/17/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"47.5","SUM_TOTAL_ON_SITE_HOURS":"24.5","sourceDate":"2008-10-02"},{"SOURCE_ROW_NUMBER":"1110770","EVENT_NO":"4016578","INSPECTION_BEGIN_DT":"10/01/2008","INSPECTION_END_DT":"10/02/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2008-10-01"},{"SOURCE_ROW_NUMBER":"807634","EVENT_NO":"6230054","INSPECTION_BEGIN_DT":"09/16/2008","INSPECTION_END_DT":"09/16/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2008-09-16"},{"SOURCE_ROW_NUMBER":"830094","EVENT_NO":"4018203","INSPECTION_BEGIN_DT":"09/04/2008","INSPECTION_END_DT":"09/15/2008","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2008-09-04"},{"SOURCE_ROW_NUMBER":"122053","EVENT_NO":"4016523","INSPECTION_BEGIN_DT":"08/29/2008","INSPECTION_END_DT":"08/29/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.75","SUM_TOTAL_ON_SITE_HOURS":"7.75","sourceDate":"2008-08-29"},{"SOURCE_ROW_NUMBER":"345233","EVENT_NO":"4016398","INSPECTION_BEGIN_DT":"08/08/2008","INSPECTION_END_DT":"08/08/2008","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2008-08-08"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":11,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":1986,"employees":9,"production":0},"2005":{"hours":36911,"employees":16,"production":93991},"2006":{"hours":54692,"employees":20,"production":189969},"2007":{"hours":58951,"employees":24,"production":156997},"2008":{"hours":51518,"employees":21,"production":77105},"2009":{"hours":3004,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":25,"firstDate":"2005-09-20","lastDate":"2008-06-24","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":1445,"pelDoseTotal":983},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"168729","EVENT_NO":"4018724","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"46","PEL_DOSE_90":"30","SURVEY_TYPE":"F","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"168728","EVENT_NO":"4018724","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"67","PEL_DOSE_90":"51","SURVEY_TYPE":"F","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"168727","EVENT_NO":"4018724","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"056","ACT_DOSE_85":"73","PEL_DOSE_90":"42","SURVEY_TYPE":"F","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"168726","EVENT_NO":"4018724","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"056","ACT_DOSE_85":"61","PEL_DOSE_90":"40","SURVEY_TYPE":"F","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"168725","EVENT_NO":"4018724","SURVEY_DATE":"06/24/2008","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"056","ACT_DOSE_85":"64","PEL_DOSE_90":"42","SURVEY_TYPE":"F","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"168730","EVENT_NO":"4018724","SURVEY_DATE":"05/21/2008","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"056","ACT_DOSE_85":"160","PEL_DOSE_90":"144","SURVEY_TYPE":"I","sourceDate":"2008-05-21"},{"SOURCE_ROW_NUMBER":"168724","EVENT_NO":"4018724","SURVEY_DATE":"05/21/2008","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"056","ACT_DOSE_85":"85","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2008-05-21"},{"SOURCE_ROW_NUMBER":"168723","EVENT_NO":"4018724","SURVEY_DATE":"05/21/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"116","PEL_DOSE_90":"85","SURVEY_TYPE":"I","sourceDate":"2008-05-21"},{"SOURCE_ROW_NUMBER":"168722","EVENT_NO":"4018724","SURVEY_DATE":"05/21/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"100","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2008-05-21"},{"SOURCE_ROW_NUMBER":"168738","EVENT_NO":"4051950","SURVEY_DATE":"03/20/2008","OCCUPATION_CD_DESC":"FORKLIFT OPERATOR","MACHINE_CD":"17","MANUFACTURER_CD":"018","ACT_DOSE_85":"21","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2008-03-20"},{"SOURCE_ROW_NUMBER":"168746","EVENT_NO":"4051981","SURVEY_DATE":"06/15/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"49","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2007-06-15"},{"SOURCE_ROW_NUMBER":"168745","EVENT_NO":"4051981","SURVEY_DATE":"06/15/2007","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"056","ACT_DOSE_85":"29","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2007-06-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":11,"firstDate":"2005-04-06","lastDate":"2008-05-28","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":5.4,"validSamples":11,"quartzPctTotal":43.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"154795","CASSETTE_NO":"57669259","SAMPLE_DT":"05/28/2008","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-05-28"},{"SOURCE_ROW_NUMBER":"69752","CASSETTE_NO":"57668871","SAMPLE_DT":"02/05/2008","QUARTZ_PCT":"01.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"165290","CASSETTE_NO":"57668903","SAMPLE_DT":"01/23/2008","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-01-23"},{"SOURCE_ROW_NUMBER":"43969","CASSETTE_NO":"57669053","SAMPLE_DT":"11/15/2007","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-11-15"},{"SOURCE_ROW_NUMBER":"28372","CASSETTE_NO":"57669047","SAMPLE_DT":"11/15/2007","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-11-15"},{"SOURCE_ROW_NUMBER":"17664","CASSETTE_NO":"57668515","SAMPLE_DT":"09/05/2007","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-09-05"},{"SOURCE_ROW_NUMBER":"15069","CASSETTE_NO":"57628500","SAMPLE_DT":"06/20/2007","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-20"},{"SOURCE_ROW_NUMBER":"131839","CASSETTE_NO":"57574580","SAMPLE_DT":"12/20/2006","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-12-20"},{"SOURCE_ROW_NUMBER":"118597","CASSETTE_NO":"57579825","SAMPLE_DT":"04/27/2006","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-27"},{"SOURCE_ROW_NUMBER":"38517","CASSETTE_NO":"57579985","SAMPLE_DT":"03/01/2006","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-03-01"},{"SOURCE_ROW_NUMBER":"133339","CASSETTE_NO":"57516214","SAMPLE_DT":"04/06/2005","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":161,"firstDate":"2004-12-29","lastDate":"2009-03-18","metrics":{"ss":70,"amountDue":52257,"contested":1,"amountPaid":52257,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":52257},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1972704","VIOLATION_NO":"7061342","VIOLATION_ISSUE_DT":"03/18/2009","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/27/2009","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2009-03-18"},{"SOURCE_ROW_NUMBER":"1972703","VIOLATION_NO":"7061341","VIOLATION_ISSUE_DT":"03/18/2009","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/18/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-03-18"},{"SOURCE_ROW_NUMBER":"1972818","VIOLATION_NO":"7060620","VIOLATION_ISSUE_DT":"10/03/2008","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"14","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/03/2008","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2008-10-03"},{"SOURCE_ROW_NUMBER":"1972817","VIOLATION_NO":"7058824","VIOLATION_ISSUE_DT":"10/02/2008","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"10/08/2008","CONTESTED_IND":"N","sourceDate":"2008-10-02"},{"SOURCE_ROW_NUMBER":"1972797","VIOLATION_NO":"7061316","VIOLATION_ISSUE_DT":"10/02/2008","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"9","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/02/2008","PROPOSED_PENALTY":"1657","AMOUNT_DUE":"1657","AMOUNT_PAID":"1657","CONTESTED_IND":"N","sourceDate":"2008-10-02"},{"SOURCE_ROW_NUMBER":"1972752","VIOLATION_NO":"7054702","VIOLATION_ISSUE_DT":"09/18/2008","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/18/2008","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2008-09-18"},{"SOURCE_ROW_NUMBER":"1972751","VIOLATION_NO":"7019383","VIOLATION_ISSUE_DT":"09/11/2008","SIG_SUB":"N","PART_SECTION":"75.340(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/12/2008","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"634","CONTESTED_IND":"N","sourceDate":"2008-09-11"},{"SOURCE_ROW_NUMBER":"1972750","VIOLATION_NO":"7019382","VIOLATION_ISSUE_DT":"09/09/2008","SIG_SUB":"Y","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/09/2008","PROPOSED_PENALTY":"3143","AMOUNT_DUE":"3143","AMOUNT_PAID":"3143","CONTESTED_IND":"N","sourceDate":"2008-09-09"},{"SOURCE_ROW_NUMBER":"1972749","VIOLATION_NO":"7019381","VIOLATION_ISSUE_DT":"09/09/2008","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/10/2008","PROPOSED_PENALTY":"1111","AMOUNT_DUE":"1111","AMOUNT_PAID":"1111","CONTESTED_IND":"N","sourceDate":"2008-09-09"},{"SOURCE_ROW_NUMBER":"1972748","VIOLATION_NO":"7019380","VIOLATION_ISSUE_DT":"09/08/2008","SIG_SUB":"Y","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2008","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"1972747","VIOLATION_NO":"7019379","VIOLATION_ISSUE_DT":"09/08/2008","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/08/2008","PROPOSED_PENALTY":"1111","AMOUNT_DUE":"1111","AMOUNT_PAID":"1111","CONTESTED_IND":"N","sourceDate":"2008-09-08"},{"SOURCE_ROW_NUMBER":"1972782","VIOLATION_NO":"7058820","VIOLATION_ISSUE_DT":"09/05/2008","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"09/12/2008","CONTESTED_IND":"N","sourceDate":"2008-09-05"}]}],"safety":{"href":"/api/v1/mines/3609159/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609159/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Underground electrical installations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.340","part":"75","subchapter":"O","subpart":"D","id":"75.340","citation":"30 CFR 75.340","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609159","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}