{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3609072","name":"Rocky Top Mine","status":"Abandoned","status_date":"2009-01-20","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Anthracite)","state":"PA","county":"Schuylkill","nearest_town":"Williamstown","operator_id":"0064163","operator_name":"Cruz Bay Trading Inc","controller_id":"0053689","controller_name":"Jefferson  Martin; Susan  Deikman","district":"M2","office":"Frackville PA Field Office","employees":0,"latitude":40.602777,"longitude":-76.6},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":197},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3609072","name":"Rocky Top Mine"},"operator":{"type":"operator","id":"0064163","name":"Cruz Bay Trading Inc"},"controller":{"type":"controller","id":"0053689","name":"Jefferson  Martin; Susan  Deikman"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050245","name":"H & M Coal Contracting"},"object":{"type":"mine","id":"3609072","name":"Rocky Top Mine"},"validFrom":"2002-04-15","validTo":"2004-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0050245|2002-04-15|2004-04-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12954","name":"Larry  Madenford et al"},"object":{"type":"mine","id":"3609072","name":"Rocky Top Mine"},"validFrom":"2002-04-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|C12954|2002-04-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12954","name":"Larry  Madenford et al"},"object":{"type":"operator","id":"0050245","name":"H & M Coal Contracting"},"validFrom":"2002-04-15","validTo":"2004-04-18","current":false,"derived":true,"evidenceMineId":"3609072","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0050245|2002-04-15|C12954|2002-04-15|88244"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0052466","name":"J & J Coal Co"},"object":{"type":"mine","id":"3609072","name":"Rocky Top Mine"},"validFrom":"2004-04-19","validTo":"2008-07-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0052466|2004-04-19|2008-07-22"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0043311","name":"John M  Steckley"},"object":{"type":"mine","id":"3609072","name":"Rocky Top Mine"},"validFrom":"2004-04-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0043311|2004-04-19|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0043311","name":"John M  Steckley"},"object":{"type":"operator","id":"0052466","name":"J & J Coal Co"},"validFrom":"2004-04-19","validTo":"2008-07-22","current":false,"derived":true,"evidenceMineId":"3609072","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0052466|2004-04-19|0043311|2004-04-19|4560"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0053689","name":"Jefferson  Martin  et al"},"object":{"type":"mine","id":"3609072","name":"Rocky Top Mine"},"validFrom":"2005-09-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0053689|2005-09-13|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0064163","name":"Cruz Bay Trading Inc"},"object":{"type":"mine","id":"3609072","name":"Rocky Top Mine"},"validFrom":"2008-07-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0064163|2008-07-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0053689","name":"Jefferson  Martin  et al"},"object":{"type":"operator","id":"0064163","name":"Cruz Bay Trading Inc"},"validFrom":"2008-07-23","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609072","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0064163|2008-07-23|0053689|2005-09-13|6852"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0053689","name":"Susan  Deikman  et al"},"object":{"type":"operator","id":"0064163","name":"Cruz Bay Trading Inc"},"validFrom":"2008-07-23","validTo":null,"current":true,"derived":true,"evidenceMineId":"3609072","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3609072|0064163|2008-07-23|0053689|2005-09-13|6853"}}],"coverage":{"historyRecords":4,"edgeCount":10,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-01-20","lastDate":"2009-01-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":19,"firstDate":"2002-07-30","lastDate":"2005-11-22","metrics":{"ss":7,"delinquent":19,"recentRows":0,"paidPenalty":30,"proposedPenalty":1422,"currentAssessment":1380},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1306940","VIOLATION_NO":"7007856","ISSUE_DT":"11/22/2005","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"291.00","CURRENT_ASSESSMENT_AMT":"291.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"1306273","VIOLATION_NO":"4370363","ISSUE_DT":"10/25/2004","CFR_STANDARD_CD":"75.1730(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-10-25"},{"SOURCE_ROW_NUMBER":"1306272","VIOLATION_NO":"4370362","ISSUE_DT":"10/25/2004","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"30.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-10-25"},{"SOURCE_ROW_NUMBER":"1306176","VIOLATION_NO":"4370361","ISSUE_DT":"09/30/2004","CFR_STANDARD_CD":"75.1713-5","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-09-30"},{"SOURCE_ROW_NUMBER":"1305671","VIOLATION_NO":"7005358","ISSUE_DT":"01/27/2004","CFR_STANDARD_CD":"75.1100-2(i)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"1305670","VIOLATION_NO":"7005355","ISSUE_DT":"01/21/2004","CFR_STANDARD_CD":"75.1713-5","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"656618","VIOLATION_NO":"7005309","ISSUE_DT":"09/11/2003","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"656617","VIOLATION_NO":"7005308","ISSUE_DT":"09/02/2003","CFR_STANDARD_CD":"75.372(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-09-02"},{"SOURCE_ROW_NUMBER":"656608","VIOLATION_NO":"7005252","ISSUE_DT":"06/24/2003","CFR_STANDARD_CD":"75.1323(j)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"75.00","CURRENT_ASSESSMENT_AMT":"75.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-06-24"},{"SOURCE_ROW_NUMBER":"656607","VIOLATION_NO":"7005249","ISSUE_DT":"05/22/2003","CFR_STANDARD_CD":"75.1714-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"656606","VIOLATION_NO":"7005248","ISSUE_DT":"05/19/2003","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"75.00","CURRENT_ASSESSMENT_AMT":"75.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-19"},{"SOURCE_ROW_NUMBER":"656605","VIOLATION_NO":"7005247","ISSUE_DT":"05/13/2003","CFR_STANDARD_CD":"75.310(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-05-13"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2005-03-11","lastDate":"2006-09-14","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":321,"originalPenalty":363},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"192512","VIOLATION_NO":"7007856","DOCKET_NO":"PENN 2006-188","DECISION_DT":"09/14/2006","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"291.00","DECISION_PENALTY_AMT":"291.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2006-09-14"},{"SOURCE_ROW_NUMBER":"186590","VIOLATION_NO":"4370362","DOCKET_NO":"PENN 2005-81","DECISION_DT":"03/11/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2005-03-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":50,"firstDate":"2002-09-25","lastDate":"2004-12-10","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":42,"maxConcentration":45.988,"concentrationTotal":139.642},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"526725","CASS_NUM":"50768808","SMP_TAKEN_DT":"12/10/2004","CONC":".095","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-10"},{"SOURCE_ROW_NUMBER":"1088780","CASS_NUM":"50768806","SMP_TAKEN_DT":"12/9/2004","CONC":".07","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-09"},{"SOURCE_ROW_NUMBER":"1600606","CASS_NUM":"50768802","SMP_TAKEN_DT":"12/8/2004","CONC":".055","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-08"},{"SOURCE_ROW_NUMBER":"710237","CASS_NUM":"50768800","SMP_TAKEN_DT":"12/7/2004","CONC":"1.19","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-07"},{"SOURCE_ROW_NUMBER":"98488","CASS_NUM":"50768801","SMP_TAKEN_DT":"12/6/2004","CONC":".028","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-12-06"},{"SOURCE_ROW_NUMBER":"880931","CASS_NUM":"57484430","SMP_TAKEN_DT":"11/8/2004","CONC":".005","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER/BLACKSMITH","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-08"},{"SOURCE_ROW_NUMBER":"1106298","CASS_NUM":"57484443","SMP_TAKEN_DT":"11/1/2004","CONC":".222","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-01"},{"SOURCE_ROW_NUMBER":"511576","CASS_NUM":"57484420","SMP_TAKEN_DT":"11/1/2004","CONC":".154","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-11-01"},{"SOURCE_ROW_NUMBER":"1563290","CASS_NUM":"57484433","SMP_TAKEN_DT":"9/24/2004","CONC":".065","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-09-24"},{"SOURCE_ROW_NUMBER":"1389192","CASS_NUM":"57484482","SMP_TAKEN_DT":"9/24/2004","CONC":".056","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-09-24"},{"SOURCE_ROW_NUMBER":"455516","CASS_NUM":"50754913","SMP_TAKEN_DT":"9/24/2004","CONC":".049","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-09-24"},{"SOURCE_ROW_NUMBER":"924382","CASS_NUM":"50754905","SMP_TAKEN_DT":"9/23/2004","CONC":".346","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-09-23"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2004-11-23","lastDate":"2004-11-23","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":2,"firstDate":"2004-10-25","lastDate":"2005-11-22","metrics":{"decisions":2,"ssChanged":1,"recentRows":0,"decisionPenalty":321,"proposedPenalty":363},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"3030","CITATION_NO":"7007856","CITATION_ISSUE_DT":"11/22/2005","DOCKET_NO":"PENN 2006-188","DECISION_DT":"09/14/2006","CFR_STANDARD_CODE":"75.1711","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"291.00","DECISION_PENALTY_AMT":"291.00","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"396370","CITATION_NO":"4370362","CITATION_ISSUE_DT":"10/25/2004","DOCKET_NO":"PENN 2005-81","DECISION_DT":"03/11/2005","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"30.00","sourceDate":"2004-10-25"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2002-04-15","lastDate":"2008-07-23","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":56,"firstDate":"2002-04-15","lastDate":"2010-07-22","metrics":{"inspectors":58,"recentRows":0,"onSiteHours":362.25,"inspectionHours":710.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"628482","EVENT_NO":"4306760","INSPECTION_BEGIN_DT":"07/22/2010","INSPECTION_END_DT":"07/22/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2010-07-22"},{"SOURCE_ROW_NUMBER":"1156559","EVENT_NO":"4304039","INSPECTION_BEGIN_DT":"04/24/2009","INSPECTION_END_DT":"04/29/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2009-04-24"},{"SOURCE_ROW_NUMBER":"304368","EVENT_NO":"4304096","INSPECTION_BEGIN_DT":"12/17/2008","INSPECTION_END_DT":"12/17/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2008-12-17"},{"SOURCE_ROW_NUMBER":"595458","EVENT_NO":"4304078","INSPECTION_BEGIN_DT":"09/04/2008","INSPECTION_END_DT":"09/04/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2008-09-04"},{"SOURCE_ROW_NUMBER":"876417","EVENT_NO":"4302282","INSPECTION_BEGIN_DT":"11/22/2005","INSPECTION_END_DT":"11/28/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"74440","EVENT_NO":"4302629","INSPECTION_BEGIN_DT":"08/30/2005","INSPECTION_END_DT":"08/30/2005","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-08-30"},{"SOURCE_ROW_NUMBER":"394618","EVENT_NO":"4302623","INSPECTION_BEGIN_DT":"08/05/2005","INSPECTION_END_DT":"08/05/2005","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2005-08-05"},{"SOURCE_ROW_NUMBER":"287306","EVENT_NO":"4301546","INSPECTION_BEGIN_DT":"08/01/2005","INSPECTION_END_DT":"08/17/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-08-01"},{"SOURCE_ROW_NUMBER":"588147","EVENT_NO":"4301529","INSPECTION_BEGIN_DT":"04/08/2005","INSPECTION_END_DT":"04/14/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2005-04-08"},{"SOURCE_ROW_NUMBER":"772246","EVENT_NO":"4301506","INSPECTION_BEGIN_DT":"02/09/2005","INSPECTION_END_DT":"02/14/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2005-02-09"},{"SOURCE_ROW_NUMBER":"329195","EVENT_NO":"4301555","INSPECTION_BEGIN_DT":"01/20/2005","INSPECTION_END_DT":"01/20/2005","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-01-20"},{"SOURCE_ROW_NUMBER":"80404","EVENT_NO":"4301708","INSPECTION_BEGIN_DT":"01/14/2005","INSPECTION_END_DT":"03/15/2005","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-01-14"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":28,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005-Q3":{"hours":0,"employees":0,"production":0},"2005-Q2":{"hours":25,"employees":1,"production":0},"2005-Q1":{"hours":38,"employees":1,"production":0},"2004-Q4":{"hours":840,"employees":2,"production":467},"2004-Q3":{"hours":248,"employees":3,"production":60},"2004-Q2":{"hours":347,"employees":2,"production":0},"2004-Q1":{"hours":180,"employees":2,"production":45},"2003-Q4":{"hours":1080,"employees":3,"production":240},"2003-Q3":{"hours":600,"employees":2,"production":188},"2003-Q2":{"hours":900,"employees":3,"production":140},"2003-Q1":{"hours":360,"employees":3,"production":64},"2002-Q4":{"hours":900,"employees":3,"production":88}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":2520,"employees":3,"production":136},"2003":{"hours":2940,"employees":3,"production":632},"2004":{"hours":1615,"employees":2,"production":572},"2005":{"hours":63,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":4,"firstDate":"2003-09-11","lastDate":"2004-11-08","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":21,"pelDoseTotal":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"167616","EVENT_NO":"4301417","SURVEY_DATE":"11/08/2004","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"1","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2004-11-08"},{"SOURCE_ROW_NUMBER":"167617","EVENT_NO":"4301417","SURVEY_DATE":"11/01/2004","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"8","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2004-11-01"},{"SOURCE_ROW_NUMBER":"167618","EVENT_NO":"4301452","SURVEY_DATE":"09/24/2004","OCCUPATION_CD_DESC":"WELDER","MACHINE_CD":"20","MANUFACTURER_CD":"039","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2004-09-24"},{"SOURCE_ROW_NUMBER":"167615","EVENT_NO":"4009617","SURVEY_DATE":"09/11/2003","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"10","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2003-09-11"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":2,"firstDate":"2002-09-25","lastDate":"2003-09-09","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":2.4,"validSamples":2,"quartzPctTotal":3.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"146332","CASSETTE_NO":"57461573","SAMPLE_DT":"09/09/2003","QUARTZ_PCT":"00.8","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-09-09"},{"SOURCE_ROW_NUMBER":"131849","CASSETTE_NO":"57407618","SAMPLE_DT":"09/25/2002","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-09-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":19,"firstDate":"2002-07-30","lastDate":"2005-11-22","metrics":{"ss":7,"amountDue":1380,"contested":2,"amountPaid":30,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":1422},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1968843","VIOLATION_NO":"7007856","VIOLATION_ISSUE_DT":"11/22/2005","SIG_SUB":"Y","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"291","AMOUNT_DUE":"291","AMOUNT_PAID":"0","CONTESTED_IND":"Y","DOCKET_NO":"PENN 2006-188","sourceDate":"2005-11-22"},{"SOURCE_ROW_NUMBER":"1968842","VIOLATION_NO":"4370363","VIOLATION_ISSUE_DT":"10/25/2004","SIG_SUB":"N","PART_SECTION":"75.1730(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/01/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-10-25"},{"SOURCE_ROW_NUMBER":"1968841","VIOLATION_NO":"4370362","VIOLATION_ISSUE_DT":"10/25/2004","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/01/2004","PROPOSED_PENALTY":"72","AMOUNT_DUE":"30","AMOUNT_PAID":"30","CONTESTED_IND":"Y","DOCKET_NO":"PENN 2005-81","sourceDate":"2004-10-25"},{"SOURCE_ROW_NUMBER":"1968833","VIOLATION_NO":"4370361","VIOLATION_ISSUE_DT":"09/30/2004","SIG_SUB":"N","PART_SECTION":"75.1713-5","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-09-30"},{"SOURCE_ROW_NUMBER":"1968826","VIOLATION_NO":"7005358","VIOLATION_ISSUE_DT":"01/27/2004","SIG_SUB":"N","PART_SECTION":"75.1100-2(i)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/24/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"1968825","VIOLATION_NO":"7005355","VIOLATION_ISSUE_DT":"01/21/2004","SIG_SUB":"N","PART_SECTION":"75.1713-5","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/23/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-01-21"},{"SOURCE_ROW_NUMBER":"1968836","VIOLATION_NO":"7005309","VIOLATION_ISSUE_DT":"09/11/2003","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/16/2003","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-09-11"},{"SOURCE_ROW_NUMBER":"1968835","VIOLATION_NO":"7005308","VIOLATION_ISSUE_DT":"09/02/2003","SIG_SUB":"N","PART_SECTION":"75.372(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/23/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-09-02"},{"SOURCE_ROW_NUMBER":"1968832","VIOLATION_NO":"7005252","VIOLATION_ISSUE_DT":"06/24/2003","SIG_SUB":"Y","PART_SECTION":"75.1323(j)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2003","PROPOSED_PENALTY":"75","AMOUNT_DUE":"75","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-06-24"},{"SOURCE_ROW_NUMBER":"1968831","VIOLATION_NO":"7005249","VIOLATION_ISSUE_DT":"05/22/2003","SIG_SUB":"N","PART_SECTION":"75.1714-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/04/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-05-22"},{"SOURCE_ROW_NUMBER":"1968830","VIOLATION_NO":"7005248","VIOLATION_ISSUE_DT":"05/19/2003","SIG_SUB":"Y","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2003","PROPOSED_PENALTY":"75","AMOUNT_DUE":"75","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-05-19"},{"SOURCE_ROW_NUMBER":"1968829","VIOLATION_NO":"7005247","VIOLATION_ISSUE_DT":"05/13/2003","SIG_SUB":"N","PART_SECTION":"75.310(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/04/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-05-13"}]}],"safety":{"href":"/api/v1/mines/3609072/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3609072/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Compressed air; general; compressed air systems.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1730","part":"75","subchapter":"O","subpart":"R","id":"75.1730","citation":"30 CFR 75.1730","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","heading":"First-aid training program; retraining of supervisory employees; availability to all miners.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1713-5","part":"75","subchapter":"O","subpart":"R","id":"75.1713-5","citation":"30 CFR 75.1713-5","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Mine ventilation map.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.372","part":"75","subchapter":"O","subpart":"D","id":"75.372","citation":"30 CFR 75.372","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Blasting circuits.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-N/section-75.1323","part":"75","subchapter":"O","subpart":"N","id":"75.1323","citation":"30 CFR 75.1323","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; use and location requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-2","part":"75","subchapter":"O","subpart":"R","id":"75.1714-2","citation":"30 CFR 75.1714-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3609072","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}