{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3608907","name":"David Breeden Mines","status":"Abandoned","status_date":"2004-08-09","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Washington","nearest_town":"Eighty Four, Pa","operator_id":"P24568","operator_name":"David Breeden Enterprises, Inc.","controller_id":"C16015","controller_name":"Christian J  Swango","district":"C03","office":"Waynesburg PA Field Office","employees":0,"latitude":40.149444,"longitude":-80.075},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":402},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608907","name":"David Breeden Mines"},"operator":{"type":"operator","id":"P24568","name":"David Breeden Enterprises, Inc."},"controller":{"type":"controller","id":"C16015","name":"Christian J  Swango"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24568","name":"David Breeden Enterprises, Inc."},"object":{"type":"mine","id":"3608907","name":"David Breeden Mines"},"validFrom":"2001-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608907|P24568|2001-02-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C16015","name":"Christian J  Swango"},"object":{"type":"mine","id":"3608907","name":"David Breeden Mines"},"validFrom":"2001-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608907|C16015|2001-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C16015","name":"Christian J  Swango"},"object":{"type":"operator","id":"P24568","name":"David Breeden Enterprises, Inc."},"validFrom":"2001-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608907","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608907|P24568|2001-02-01|C16015|2001-02-01|98008"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2002-04-22","lastDate":"2002-04-22","metrics":{"daysLost":41,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"149098","DOCUMENT_NO":"220021260080","ACCIDENT_DT":"04/22/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Truck driver","NO_INJURIES":"1","DAYS_LOST":"41","NARRATIVE":"DRIVER WAS WALKING TO HIS TRUCK. ANOTHER TRUCK BESIDE HIM PROCEEDED TO MOVE. THE ARM TARP OF THE MOVING TRUCK CAUGHT EE ON THE SHOULDER, THROWING HIM TO THE GROUND. EE'S FOOT WAS RUN OVER BY T HE TRUCK.","sourceDate":"2002-04-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-08-09","lastDate":"2004-08-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":8,"firstDate":"2001-09-06","lastDate":"2002-03-04","metrics":{"ss":1,"delinquent":8,"recentRows":0,"paidPenalty":513,"proposedPenalty":513,"currentAssessment":513},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"667963","VIOLATION_NO":"7077192","ISSUE_DT":"03/04/2002","CFR_STANDARD_CD":"41.12","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-04"},{"SOURCE_ROW_NUMBER":"667962","VIOLATION_NO":"7077191","ISSUE_DT":"03/04/2002","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-03-04"},{"SOURCE_ROW_NUMBER":"664847","VIOLATION_NO":"7060580","ISSUE_DT":"09/10/2001","CFR_STANDARD_CD":"71.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-10"},{"SOURCE_ROW_NUMBER":"664846","VIOLATION_NO":"7060578","ISSUE_DT":"09/06/2001","CFR_STANDARD_CD":"48.28(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"86.00","CURRENT_ASSESSMENT_AMT":"86.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"664845","VIOLATION_NO":"7060577","ISSUE_DT":"09/06/2001","CFR_STANDARD_CD":"48.29(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"664844","VIOLATION_NO":"7060576","ISSUE_DT":"09/06/2001","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"664843","VIOLATION_NO":"7060575","ISSUE_DT":"09/06/2001","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"664842","VIOLATION_NO":"7060574","ISSUE_DT":"09/06/2001","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"97.00","CURRENT_ASSESSMENT_AMT":"97.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-06"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":8,"firstDate":"2002-03-05","lastDate":"2002-09-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":7,"maxConcentration":0.778,"concentrationTotal":1.484},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1226145","CASS_NUM":"57440176","SMP_TAKEN_DT":"9/3/2002","CONC":".027","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-03"},{"SOURCE_ROW_NUMBER":"698233","CASS_NUM":"57439991","SMP_TAKEN_DT":"9/3/2002","CONC":".108","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-03"},{"SOURCE_ROW_NUMBER":"383548","CASS_NUM":"57439990","SMP_TAKEN_DT":"9/3/2002","CONC":".134","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-09-03"},{"SOURCE_ROW_NUMBER":"1353451","CASS_NUM":"50636399","SMP_TAKEN_DT":"4/3/2002","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-04-03"},{"SOURCE_ROW_NUMBER":"1628262","CASS_NUM":"57352205","SMP_TAKEN_DT":"3/5/2002","CONC":".042","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"1493291","CASS_NUM":"57352188","SMP_TAKEN_DT":"3/5/2002","CONC":".115","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"1318381","CASS_NUM":"57352121","SMP_TAKEN_DT":"3/5/2002","CONC":".28","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"657589","CASS_NUM":"57352179","SMP_TAKEN_DT":"3/5/2002","CONC":".778","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-05"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2001-10-02","lastDate":"2001-10-19","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":268,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":46,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2001-02-01","lastDate":"2001-02-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":18,"firstDate":"2001-04-09","lastDate":"2004-08-20","metrics":{"inspectors":18,"recentRows":0,"onSiteHours":69.25,"inspectionHours":146.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"860062","EVENT_NO":"4023998","INSPECTION_BEGIN_DT":"08/20/2004","INSPECTION_END_DT":"08/20/2004","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2004-08-20"},{"SOURCE_ROW_NUMBER":"324670","EVENT_NO":"4023984","INSPECTION_BEGIN_DT":"06/30/2004","INSPECTION_END_DT":"07/20/2004","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2004-06-30"},{"SOURCE_ROW_NUMBER":"552530","EVENT_NO":"4023920","INSPECTION_BEGIN_DT":"01/07/2004","INSPECTION_END_DT":"01/07/2004","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"1133570","EVENT_NO":"4023180","INSPECTION_BEGIN_DT":"08/07/2003","INSPECTION_END_DT":"08/07/2003","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2003-08-07"},{"SOURCE_ROW_NUMBER":"281047","EVENT_NO":"4023144","INSPECTION_BEGIN_DT":"05/13/2003","INSPECTION_END_DT":"05/13/2003","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2003-05-13"},{"SOURCE_ROW_NUMBER":"391345","EVENT_NO":"4022795","INSPECTION_BEGIN_DT":"01/27/2003","INSPECTION_END_DT":"01/29/2003","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2003-01-27"},{"SOURCE_ROW_NUMBER":"537462","EVENT_NO":"4022760","INSPECTION_BEGIN_DT":"10/16/2002","INSPECTION_END_DT":"10/16/2002","ACTIVITY_CODE":"CFA","ACTIVITY":"MINE IDLE","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2002-10-16"},{"SOURCE_ROW_NUMBER":"780341","EVENT_NO":"4022718","INSPECTION_BEGIN_DT":"09/03/2002","INSPECTION_END_DT":"09/12/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2002-09-03"},{"SOURCE_ROW_NUMBER":"586429","EVENT_NO":"4022717","INSPECTION_BEGIN_DT":"09/03/2002","INSPECTION_END_DT":"09/12/2002","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2002-09-03"},{"SOURCE_ROW_NUMBER":"357901","EVENT_NO":"4022723","INSPECTION_BEGIN_DT":"09/03/2002","INSPECTION_END_DT":"09/03/2002","ACTIVITY_CODE":"CFC","ACTIVITY":"OTHER CONTACTS","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".75","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2002-09-03"},{"SOURCE_ROW_NUMBER":"639804","EVENT_NO":"4022711","INSPECTION_BEGIN_DT":"08/20/2002","INSPECTION_END_DT":"09/12/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.75","SUM_TOTAL_ON_SITE_HOURS":"7.75","sourceDate":"2002-08-20"},{"SOURCE_ROW_NUMBER":"743172","EVENT_NO":"4022045","INSPECTION_BEGIN_DT":"03/05/2002","INSPECTION_END_DT":"03/06/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2002-03-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":27,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q3":{"hours":0,"employees":0,"production":0},"2004-Q1":{"hours":0,"employees":0,"production":0},"2003-Q4":{"hours":0,"employees":0,"production":0},"2003-Q3":{"hours":0,"employees":0,"production":0},"2003-Q2":{"hours":0,"employees":0,"production":0},"2003-Q1":{"hours":0,"employees":0,"production":0},"2002-Q4":{"hours":2663,"employees":12,"production":13398},"2002-Q3":{"hours":7727,"employees":14,"production":43079},"2002-Q2":{"hours":8297,"employees":13,"production":45687},"2002-Q1":{"hours":8823,"employees":16,"production":46327},"2001-Q4":{"hours":10721,"employees":18,"production":52100},"2001-Q3":{"hours":9813,"employees":16,"production":61882}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":32497,"employees":15,"production":180963},"2002":{"hours":27510,"employees":14,"production":148491}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":4,"firstDate":"2002-03-05","lastDate":"2002-03-05","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":154,"pelDoseTotal":51},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"166855","EVENT_NO":"4022045","SURVEY_DATE":"03/05/2002","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"055","ACT_DOSE_85":"4","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"166854","EVENT_NO":"4022045","SURVEY_DATE":"03/05/2002","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"33","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"166853","EVENT_NO":"4022045","SURVEY_DATE":"03/05/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"52","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"166852","EVENT_NO":"4022045","SURVEY_DATE":"03/05/2002","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"65","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2002-03-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":4,"firstDate":"2002-03-05","lastDate":"2002-04-03","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":19,"validSamples":3,"quartzPctTotal":31.5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94672","CASSETTE_NO":"50648423","SAMPLE_DT":"04/03/2002","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-04-03"},{"SOURCE_ROW_NUMBER":"15520","CASSETTE_NO":"50636399","SAMPLE_DT":"04/03/2002","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2002-04-03"},{"SOURCE_ROW_NUMBER":"12657","CASSETTE_NO":"57352179","SAMPLE_DT":"03/05/2002","QUARTZ_PCT":"09.4","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-05"},{"SOURCE_ROW_NUMBER":"8497","CASSETTE_NO":"57352121","SAMPLE_DT":"03/05/2002","QUARTZ_PCT":"19.0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-05"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":9,"firstDate":"2001-09-06","lastDate":"2002-03-04","metrics":{"ss":1,"amountDue":513,"contested":0,"amountPaid":513,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":513},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1965188","VIOLATION_NO":"7077192","VIOLATION_ISSUE_DT":"03/04/2002","SIG_SUB":"N","PART_SECTION":"41.12","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/03/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-03-04"},{"SOURCE_ROW_NUMBER":"1965187","VIOLATION_NO":"7077191","VIOLATION_ISSUE_DT":"03/04/2002","SIG_SUB":"N","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/05/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-03-04"},{"SOURCE_ROW_NUMBER":"1965195","VIOLATION_NO":"7060580","VIOLATION_ISSUE_DT":"09/10/2001","SIG_SUB":"N","PART_SECTION":"71.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/05/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-10"},{"SOURCE_ROW_NUMBER":"1965194","VIOLATION_NO":"7060579","VIOLATION_ISSUE_DT":"09/10/2001","SIG_SUB":"N","PART_SECTION":"48.28(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/18/2001","CONTESTED_IND":"N","sourceDate":"2001-09-10"},{"SOURCE_ROW_NUMBER":"1965193","VIOLATION_NO":"7060578","VIOLATION_ISSUE_DT":"09/06/2001","SIG_SUB":"N","PART_SECTION":"48.28(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/10/2001","PROPOSED_PENALTY":"86","AMOUNT_DUE":"86","AMOUNT_PAID":"86","CONTESTED_IND":"N","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"1965192","VIOLATION_NO":"7060577","VIOLATION_ISSUE_DT":"09/06/2001","SIG_SUB":"N","PART_SECTION":"48.29(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/10/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"1965191","VIOLATION_NO":"7060576","VIOLATION_ISSUE_DT":"09/06/2001","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/10/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"1965190","VIOLATION_NO":"7060575","VIOLATION_ISSUE_DT":"09/06/2001","SIG_SUB":"N","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/10/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-06"},{"SOURCE_ROW_NUMBER":"1965189","VIOLATION_NO":"7060574","VIOLATION_ISSUE_DT":"09/06/2001","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/06/2001","PROPOSED_PENALTY":"97","AMOUNT_DUE":"97","AMOUNT_PAID":"97","CONTESTED_IND":"N","sourceDate":"2001-09-06"}]}],"safety":{"href":"/api/v1/mines/3608907/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608907/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Changes; notification by operator.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-G/part-41/subpart-B/section-41.12","part":"41","subchapter":"G","subpart":"B","id":"41.12","citation":"30 CFR 41.12","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER G—FILING AND OTHER ADMINISTRATIVE REQUIREMENTS","partHeading":"PART 41—NOTIFICATION OF LEGAL IDENTITY","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","heading":"Bathing facilities; change rooms; sanitary flush toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-E/section-71.400","part":"71","subchapter":"O","subpart":"E","id":"71.400","citation":"30 CFR 71.400","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Annual refresher training of miners; minimum courses of instruction; hours of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.28","part":"48","subchapter":"H","subpart":"B","id":"48.28","citation":"30 CFR 48.28","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 48.29","heading":"Records of training.","id":"48.29","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.29","part":"48","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"B","subpartHeading":"Subpart B—Training and Retraining of Miners Working at Surface Mines and Surface Areas of Underground Mines","text":"(a) Upon a miner's completion of each MSHA approved training program, the operator shall record and certify on MSHA form 5000-23 that the miner has received the specified training. A copy of the training certificate shall be given to the miner at the completion of the training. The training certificates for each miner shall be available at the mine site for inspection by MSHA and for examination by the miners, the miners' representative and State inspection agencies. When a miner leaves the operator's employ, the miner shall be entitled to a copy of his training certificates.\n\n(b) False certification that training was given shall be punishable under section 110 (a) and (f) of the Act.\n\n(c) Copies of training certificates for currently employed miners shall be kept at the mine site for 2 years, or for 60 days after termination of employment.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[43 FR 47459, Oct. 13, 1978, as amended at 47 FR 14706, Apr. 6, 1982; 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608907","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}