{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"3608773","name":"Rosebud #3 Armstrong Run Portal","status":"Abandoned and Sealed","status_date":"2002-07-15","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Armstrong","nearest_town":"Karns City","operator_id":"P09635","operator_name":"Rosebud Mining Company","controller_id":"C07485","controller_name":"J Clifford  Forrest III","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":41.014167,"longitude":-79.616667},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":367},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608773","name":"Rosebud #3 Armstrong Run Portal"},"operator":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"controller":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"mine","id":"3608773","name":"Rosebud #3 Armstrong Run Portal"},"validFrom":"1979-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3608773|C07485|1979-08-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"object":{"type":"mine","id":"3608773","name":"Rosebud #3 Armstrong Run Portal"},"validFrom":"1999-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3608773|P09635|1999-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"validFrom":"1999-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608773","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3608773|P09635|1999-02-01|C07485|1979-08-01|74799"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":10,"firstDate":"2000-04-25","lastDate":"2001-03-27","metrics":{"daysLost":151,"injuries":10,"fatalities":0,"recentRows":0,"restrictedDays":25,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"50086","DOCUMENT_NO":"220010920017","ACCIDENT_DT":"03/27/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"THE WORKERS GLOVE GOT CAUGHT ON THE ROTATING DRILL STEEL WHILE HE WAS INSTALLING ROOF BOLTS.","sourceDate":"2001-03-27"},{"SOURCE_ROW_NUMBER":"140420","DOCUMENT_NO":"220003080025","ACCIDENT_DT":"10/23/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"THE MAN WALKED BETWEEN 2 SCOOPS A COWORKER MOVED THE 1 SCOOP & PINCHED THE EE'S RIGHT LEG BETWEEN THE MOVING ONE & THE SATIONARY ONE","sourceDate":"2000-10-23"},{"SOURCE_ROW_NUMBER":"136002","DOCUMENT_NO":"220002640025","ACCIDENT_DT":"09/14/2000","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","NARRATIVE":"THE FOREMAN WAS OPERATING THE SCOOP; HE STRUCK HIS HEAD AGAINST THE MINE ROOF.","sourceDate":"2000-09-14"},{"SOURCE_ROW_NUMBER":"217897","DOCUMENT_NO":"220002590012","ACCIDENT_DT":"09/11/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner helper, Coal mole helper, Bridgeman","NO_INJURIES":"1","DAYS_LOST":"30","NARRATIVE":"THE MAN HAS HAD TROUBLE WITH HIS KNEES FOR A COUPLE OF YEARS. THE MAN WENT TO THE DR ON 8-30-00, AND WAS TOLD HIS KNEE WOULDN'T BE RIGHT UNTIL IT WAS OPERATED ON. HE WAS OPERATED ON 9-11-00.","sourceDate":"2000-09-11"},{"SOURCE_ROW_NUMBER":"200524","DOCUMENT_NO":"220002590013","ACCIDENT_DT":"09/06/2000","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"EMPLOYEE HAD PARKED A SUPPLY CAR; HE THEN TRIED TO GET BACK AROUND IT. WHEN HE WENT PAST THE CAR, THE SCOOP BUMPED A POST, KNOCKING IT DOWN; A PIECE OF ROCK FELL AND HIT EMPLOYEE ON THE BACK AND NECK.","sourceDate":"2000-09-06"},{"SOURCE_ROW_NUMBER":"239410","DOCUMENT_NO":"220002230034","ACCIDENT_DT":"07/31/2000","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"THE MAN WAS RIDING INTO MINE ON MANTRIP. WATER SPLASHED UP ONTO MANTRIP. THE MAN JERKED HIS BODY, SO NOT TO GET WET.","sourceDate":"2000-07-31"},{"SOURCE_ROW_NUMBER":"252290","DOCUMENT_NO":"220002430019","ACCIDENT_DT":"07/24/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"THE MAN HAD SURGERY ON HIS NECK. WHILE WORKING ON THE PUMP, THE MAN WAS SPRAYED WITH WATER. HE JERKED HIS NECK & TORE OPEN HIS STITCHES ON HIS NECK. THE MAN RETURNED TO HIS DR. ON 8-25-00, WAS TOLD NOT TO RETURN TO WORK FOR AT LEAST 3 WEEKS.","sourceDate":"2000-07-24"},{"SOURCE_ROW_NUMBER":"265232","DOCUMENT_NO":"220001790012","ACCIDENT_DT":"06/19/2000","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","DAYS_LOST":"73","NARRATIVE":"THE MAN WAS OPERATED ON FOR CARPAL TUNNEL SYNDROME ON 6/19/00.","sourceDate":"2000-06-19"},{"SOURCE_ROW_NUMBER":"97229","DOCUMENT_NO":"220001260047","ACCIDENT_DT":"05/02/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Transit man, Surveyor/Transit worker","NO_INJURIES":"1","NARRATIVE":"THE WORKER WAS HELPING TO BUILD A CEMENT BLOCK WALL. HE WAS MIXING CEMENT. THE WORKER HAD A BAG OF CEMENT SLIP OUT OF HIS HANDS. THE BAG HIT THE MORTOR PAN, FLIPPING THE PAN END UP IN THE AIR, SPLASHING CEMENT IN HIS FACE, KNOCKING HIS GLASSES AND HARD HAT OFF.","sourceDate":"2000-05-02"},{"SOURCE_ROW_NUMBER":"123026","DOCUMENT_NO":"220001240018","ACCIDENT_DT":"04/25/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"THE MAN WAS RIDING INTO THE MINE ON THE MANTRIP. HE WAS SETTING UP-RIGHT TOO HIGH. THE MAN STRUCK HIS HEAD ON THE MINE ROOF ALONG #1 TRAVELWAY.","sourceDate":"2000-04-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-07-15","lastDate":"2002-07-15","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":64,"firstDate":"2000-01-25","lastDate":"2001-08-11","metrics":{"ss":12,"delinquent":64,"recentRows":0,"paidPenalty":4675,"proposedPenalty":5518,"currentAssessment":4675},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"664883","VIOLATION_NO":"7061122","ISSUE_DT":"08/11/2001","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-11"},{"SOURCE_ROW_NUMBER":"664882","VIOLATION_NO":"7061121","ISSUE_DT":"08/10/2001","CFR_STANDARD_CD":"75.1103-4(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-10"},{"SOURCE_ROW_NUMBER":"664881","VIOLATION_NO":"7061120","ISSUE_DT":"08/06/2001","CFR_STANDARD_CD":"75.523-3(b)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-08-06"},{"SOURCE_ROW_NUMBER":"664880","VIOLATION_NO":"7061119","ISSUE_DT":"07/31/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-31"},{"SOURCE_ROW_NUMBER":"664879","VIOLATION_NO":"3953167","ISSUE_DT":"07/30/2001","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"664878","VIOLATION_NO":"3953166","ISSUE_DT":"07/30/2001","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"140.00","CURRENT_ASSESSMENT_AMT":"90.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"664877","VIOLATION_NO":"3953165","ISSUE_DT":"07/30/2001","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"664723","VIOLATION_NO":"7060915","ISSUE_DT":"05/16/2001","CFR_STANDARD_CD":"75.523-2(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-05-16"},{"SOURCE_ROW_NUMBER":"664722","VIOLATION_NO":"7060914","ISSUE_DT":"05/15/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-05-15"},{"SOURCE_ROW_NUMBER":"664721","VIOLATION_NO":"7060913","ISSUE_DT":"05/15/2001","CFR_STANDARD_CD":"75.523-2(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-05-15"},{"SOURCE_ROW_NUMBER":"664720","VIOLATION_NO":"7060912","ISSUE_DT":"05/15/2001","CFR_STANDARD_CD":"75.523-2(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-05-15"},{"SOURCE_ROW_NUMBER":"664719","VIOLATION_NO":"7060911","ISSUE_DT":"05/15/2001","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-05-15"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":23,"firstDate":"2000-03-24","lastDate":"2002-02-04","metrics":{"appeals":0,"decisions":23,"recentRows":0,"decisionPenalty":2132,"originalPenalty":3293},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"480027","VIOLATION_NO":"3953166","DOCKET_NO":"PENN20020002","DECISION_DT":"02/04/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"140.00","DECISION_PENALTY_AMT":"90.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2002-02-04"},{"SOURCE_ROW_NUMBER":"479655","VIOLATION_NO":"7060636","DOCKET_NO":"PENN20010151","DECISION_DT":"10/31/2001","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"242.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2001-10-31"},{"SOURCE_ROW_NUMBER":"479541","VIOLATION_NO":"7060643","DOCKET_NO":"PENN20010151","DECISION_DT":"10/31/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"242.00","DECISION_PENALTY_AMT":"221.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2001-10-31"},{"SOURCE_ROW_NUMBER":"479424","VIOLATION_NO":"7060641","DOCKET_NO":"PENN20010151","DECISION_DT":"10/31/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"242.00","DECISION_PENALTY_AMT":"221.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2001-10-31"},{"SOURCE_ROW_NUMBER":"237977","VIOLATION_NO":"7059897","DOCKET_NO":"PENN20010053","DECISION_DT":"03/08/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"140.00","DECISION_PENALTY_AMT":"140.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2001-03-08"},{"SOURCE_ROW_NUMBER":"237976","VIOLATION_NO":"7059896","DOCKET_NO":"PENN20010053","DECISION_DT":"03/08/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"140.00","DECISION_PENALTY_AMT":"70.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2001-03-08"},{"SOURCE_ROW_NUMBER":"479654","VIOLATION_NO":"7060311","DOCKET_NO":"PENN20010016","DECISION_DT":"01/05/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"140.00","DECISION_PENALTY_AMT":"91.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2001-01-05"},{"SOURCE_ROW_NUMBER":"238721","VIOLATION_NO":"7060310","DOCKET_NO":"PENN20010016","DECISION_DT":"01/05/2001","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"97.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2001-01-05"},{"SOURCE_ROW_NUMBER":"480026","VIOLATION_NO":"7060413","DOCKET_NO":"PENN20010002","DECISION_DT":"12/08/2000","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"97.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2000-12-08"},{"SOURCE_ROW_NUMBER":"480025","VIOLATION_NO":"3953161","DOCKET_NO":"PENN20010002","DECISION_DT":"12/08/2000","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"140.00","DECISION_PENALTY_AMT":"75.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2000-12-08"},{"SOURCE_ROW_NUMBER":"479653","VIOLATION_NO":"7045299","DOCKET_NO":"PENN20010002","DECISION_DT":"12/08/2000","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"140.00","DECISION_PENALTY_AMT":"75.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2000-12-08"},{"SOURCE_ROW_NUMBER":"479540","VIOLATION_NO":"7060402","DOCKET_NO":"PENN20010002","DECISION_DT":"12/08/2000","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"140.00","DECISION_PENALTY_AMT":"75.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2000-12-08"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":112,"firstDate":"2000-01-03","lastDate":"2001-08-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":112,"maxConcentration":2.286,"concentrationTotal":66.66},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1642841","CASS_NUM":"57340592","SMP_TAKEN_DT":"8/14/2001","CONC":".723","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"1214107","CASS_NUM":"57340665","SMP_TAKEN_DT":"8/14/2001","CONC":".116","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"1155886","CASS_NUM":"57340658","SMP_TAKEN_DT":"8/14/2001","CONC":".538","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"669809","CASS_NUM":"57340672","SMP_TAKEN_DT":"8/14/2001","CONC":"1.972","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"483357","CASS_NUM":"57340606","SMP_TAKEN_DT":"8/14/2001","CONC":"1.494","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"991587","CASS_NUM":"50563308","SMP_TAKEN_DT":"8/9/2001","CONC":".209","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-08-09"},{"SOURCE_ROW_NUMBER":"1581737","CASS_NUM":"50457681","SMP_TAKEN_DT":"7/11/2001","CONC":".231","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-11"},{"SOURCE_ROW_NUMBER":"460165","CASS_NUM":"50457793","SMP_TAKEN_DT":"7/11/2001","CONC":".311","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-11"},{"SOURCE_ROW_NUMBER":"1162137","CASS_NUM":"50457670","SMP_TAKEN_DT":"7/10/2001","CONC":".904","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-10"},{"SOURCE_ROW_NUMBER":"1160965","CASS_NUM":"50534214","SMP_TAKEN_DT":"7/10/2001","CONC":".441","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-10"},{"SOURCE_ROW_NUMBER":"496335","CASS_NUM":"50534178","SMP_TAKEN_DT":"7/9/2001","CONC":"1.072","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-07-09"},{"SOURCE_ROW_NUMBER":"1403219","CASS_NUM":"57340696","SMP_TAKEN_DT":"6/7/2001","CONC":".102","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-06-07"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1999-02-01","lastDate":"1999-02-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":50,"firstDate":"2000-01-21","lastDate":"2002-06-24","metrics":{"inspectors":52,"recentRows":0,"onSiteHours":535.5,"inspectionHours":881.75,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"373089","EVENT_NO":"4017896","INSPECTION_BEGIN_DT":"06/24/2002","INSPECTION_END_DT":"06/26/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"21","sourceDate":"2002-06-24"},{"SOURCE_ROW_NUMBER":"322363","EVENT_NO":"4048495","INSPECTION_BEGIN_DT":"05/31/2002","INSPECTION_END_DT":"06/04/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2002-05-31"},{"SOURCE_ROW_NUMBER":"860515","EVENT_NO":"4018241","INSPECTION_BEGIN_DT":"01/28/2002","INSPECTION_END_DT":"01/28/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2002-01-28"},{"SOURCE_ROW_NUMBER":"895310","EVENT_NO":"4017960","INSPECTION_BEGIN_DT":"11/26/2001","INSPECTION_END_DT":"11/27/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"1094359","EVENT_NO":"4018327","INSPECTION_BEGIN_DT":"09/04/2001","INSPECTION_END_DT":"09/04/2001","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"155835","EVENT_NO":"4018509","INSPECTION_BEGIN_DT":"08/07/2001","INSPECTION_END_DT":"08/21/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.25","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2001-08-07"},{"SOURCE_ROW_NUMBER":"616168","EVENT_NO":"4011564","INSPECTION_BEGIN_DT":"07/17/2001","INSPECTION_END_DT":"07/27/2001","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19.25","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2001-07-17"},{"SOURCE_ROW_NUMBER":"414376","EVENT_NO":"4018506","INSPECTION_BEGIN_DT":"07/12/2001","INSPECTION_END_DT":"08/16/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"66","SUM_TOTAL_ON_SITE_HOURS":"48.25","sourceDate":"2001-07-12"},{"SOURCE_ROW_NUMBER":"777201","EVENT_NO":"4017946","INSPECTION_BEGIN_DT":"06/07/2001","INSPECTION_END_DT":"06/28/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2001-06-07"},{"SOURCE_ROW_NUMBER":"14111","EVENT_NO":"4018207","INSPECTION_BEGIN_DT":"05/14/2001","INSPECTION_END_DT":"05/22/2001","ACTIVITY_CODE":"CBA","ACTIVITY":"ELECTRICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"43","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2001-05-14"},{"SOURCE_ROW_NUMBER":"894565","EVENT_NO":"4016271","INSPECTION_BEGIN_DT":"04/11/2001","INSPECTION_END_DT":"04/13/2001","ACTIVITY_CODE":"BBA","ACTIVITY":"ELECTRICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2001-04-11"},{"SOURCE_ROW_NUMBER":"633928","EVENT_NO":"4017940","INSPECTION_BEGIN_DT":"04/09/2001","INSPECTION_END_DT":"04/16/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2001-04-09"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":18,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q1":{"hours":0,"employees":0,"production":0},"2001-Q4":{"hours":0,"employees":0,"production":0},"2001-Q3":{"hours":7669,"employees":19,"production":21351},"2001-Q2":{"hours":8696,"employees":15,"production":46871},"2001-Q1":{"hours":7940,"employees":13,"production":61679},"2000-Q4":{"hours":7562,"employees":14,"production":57301},"2000-Q3":{"hours":10263,"employees":19,"production":76660},"2000-Q2":{"hours":12535,"employees":19,"production":57751},"2000-Q1":{"hours":11214,"employees":19,"production":95791}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":41574,"employees":18,"production":287503},"2001":{"hours":24305,"employees":16,"production":129901}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":11,"firstDate":"2000-04-05","lastDate":"2001-02-12","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":810,"pelDoseTotal":569},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"164545","EVENT_NO":"4017836","SURVEY_DATE":"02/12/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"103","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2001-02-12"},{"SOURCE_ROW_NUMBER":"164544","EVENT_NO":"4017836","SURVEY_DATE":"02/12/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"75","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2001-02-12"},{"SOURCE_ROW_NUMBER":"164543","EVENT_NO":"4017836","SURVEY_DATE":"02/12/2001","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"067","ACT_DOSE_85":"80","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2001-02-12"},{"SOURCE_ROW_NUMBER":"164542","EVENT_NO":"4017836","SURVEY_DATE":"02/12/2001","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"106","PEL_DOSE_90":"89","SURVEY_TYPE":"I","sourceDate":"2001-02-12"},{"SOURCE_ROW_NUMBER":"164541","EVENT_NO":"4017509","SURVEY_DATE":"04/05/2000","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"22","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2000-04-05"},{"SOURCE_ROW_NUMBER":"164540","EVENT_NO":"4017509","SURVEY_DATE":"04/05/2000","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"17","MANUFACTURER_CD":"119","ACT_DOSE_85":"32","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2000-04-05"},{"SOURCE_ROW_NUMBER":"164539","EVENT_NO":"4017508","SURVEY_DATE":"04/05/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"066","ACT_DOSE_85":"123","PEL_DOSE_90":"113","SURVEY_TYPE":"I","sourceDate":"2000-04-05"},{"SOURCE_ROW_NUMBER":"164538","EVENT_NO":"4017508","SURVEY_DATE":"04/05/2000","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"54","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2000-04-05"},{"SOURCE_ROW_NUMBER":"164537","EVENT_NO":"4017508","SURVEY_DATE":"04/05/2000","OCCUPATION_CD_DESC":"ROOF BOLTER HELPER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"80","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2000-04-05"},{"SOURCE_ROW_NUMBER":"164536","EVENT_NO":"4017508","SURVEY_DATE":"04/05/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"96","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2000-04-05"},{"SOURCE_ROW_NUMBER":"164535","EVENT_NO":"4017508","SURVEY_DATE":"04/05/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"034","ACT_DOSE_85":"39","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2000-04-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":7,"firstDate":"2000-04-11","lastDate":"2001-08-14","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":5.4,"validSamples":7,"quartzPctTotal":25.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"101086","CASSETTE_NO":"57340606","SAMPLE_DT":"08/14/2001","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-14"},{"SOURCE_ROW_NUMBER":"157755","CASSETTE_NO":"57329765","SAMPLE_DT":"04/09/2001","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-04-09"},{"SOURCE_ROW_NUMBER":"128139","CASSETTE_NO":"57329569","SAMPLE_DT":"02/07/2001","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-07"},{"SOURCE_ROW_NUMBER":"152643","CASSETTE_NO":"57290506","SAMPLE_DT":"12/05/2000","QUARTZ_PCT":"02.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-12-05"},{"SOURCE_ROW_NUMBER":"134180","CASSETTE_NO":"57289545","SAMPLE_DT":"10/25/2000","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-25"},{"SOURCE_ROW_NUMBER":"78288","CASSETTE_NO":"57276546","SAMPLE_DT":"08/04/2000","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-08-04"},{"SOURCE_ROW_NUMBER":"159534","CASSETTE_NO":"57228567","SAMPLE_DT":"04/11/2000","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-04-11"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":65,"firstDate":"2000-01-25","lastDate":"2001-08-11","metrics":{"ss":12,"amountDue":4675,"contested":18,"amountPaid":4675,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":5518},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1957003","VIOLATION_NO":"7061122","VIOLATION_ISSUE_DT":"08/11/2001","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/11/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-08-11"},{"SOURCE_ROW_NUMBER":"1957002","VIOLATION_NO":"7061121","VIOLATION_ISSUE_DT":"08/10/2001","SIG_SUB":"N","PART_SECTION":"75.1103-4(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/11/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-08-10"},{"SOURCE_ROW_NUMBER":"1957001","VIOLATION_NO":"7061120","VIOLATION_ISSUE_DT":"08/06/2001","SIG_SUB":"N","PART_SECTION":"75.523-3(b)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/06/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-08-06"},{"SOURCE_ROW_NUMBER":"1957000","VIOLATION_NO":"7061119","VIOLATION_ISSUE_DT":"07/31/2001","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/10/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-31"},{"SOURCE_ROW_NUMBER":"1956999","VIOLATION_NO":"3953167","VIOLATION_ISSUE_DT":"07/30/2001","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/30/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"1956998","VIOLATION_NO":"3953166","VIOLATION_ISSUE_DT":"07/30/2001","SIG_SUB":"Y","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/31/2001","PROPOSED_PENALTY":"140","AMOUNT_DUE":"90","AMOUNT_PAID":"90","CONTESTED_IND":"Y","DOCKET_NO":"PENN20020002","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"1956997","VIOLATION_NO":"3953165","VIOLATION_ISSUE_DT":"07/30/2001","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/31/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"1956996","VIOLATION_NO":"7060915","VIOLATION_ISSUE_DT":"05/16/2001","SIG_SUB":"N","PART_SECTION":"75.523-2(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/18/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-05-16"},{"SOURCE_ROW_NUMBER":"1956995","VIOLATION_NO":"7060914","VIOLATION_ISSUE_DT":"05/15/2001","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-05-15"},{"SOURCE_ROW_NUMBER":"1956994","VIOLATION_NO":"7060913","VIOLATION_ISSUE_DT":"05/15/2001","SIG_SUB":"N","PART_SECTION":"75.523-2(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-05-15"},{"SOURCE_ROW_NUMBER":"1956993","VIOLATION_NO":"7060912","VIOLATION_ISSUE_DT":"05/15/2001","SIG_SUB":"N","PART_SECTION":"75.523-2(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-05-15"},{"SOURCE_ROW_NUMBER":"1956992","VIOLATION_NO":"7060911","VIOLATION_ISSUE_DT":"05/15/2001","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-05-15"}]}],"safety":{"href":"/api/v1/mines/3608773/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608773/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","heading":"Deenergization of self-propelled electric face equipment; performance requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-2","part":"75","subchapter":"O","subpart":"F","id":"75.523-2","citation":"30 CFR 75.523-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":3}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608773","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}