{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3608741","name":"Penn View Mine","status":"Abandoned and Sealed","status_date":"2009-03-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Indiana","nearest_town":"Blairsville","operator_id":"P24367","operator_name":"Penn View Mining, Inc.","controller_id":"C13674","controller_name":"Thomas J  Smith","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":40.458888,"longitude":-79.144166},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1672},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608741","name":"Penn View Mine"},"operator":{"type":"operator","id":"P24367","name":"Penn View Mining, Inc."},"controller":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01097","name":"Joseph J  Peles"},"object":{"type":"mine","id":"3608741","name":"Penn View Mine"},"validFrom":"1973-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608741|C01097|1973-12-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01296","name":"Joseph Peles Coal Company"},"object":{"type":"mine","id":"3608741","name":"Penn View Mine"},"validFrom":"1998-06-01","validTo":"2000-01-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608741|P01296|1998-06-01|2000-01-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01097","name":"Joseph J  Peles"},"object":{"type":"operator","id":"P01296","name":"Joseph Peles Coal Company"},"validFrom":"1998-06-01","validTo":"2000-01-31","current":false,"derived":true,"evidenceMineId":"3608741","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608741|P01296|1998-06-01|C01097|1973-12-01|52253"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24367","name":"Penn View Mining, Inc."},"object":{"type":"mine","id":"3608741","name":"Penn View Mine"},"validFrom":"2000-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608741|P24367|2000-02-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"object":{"type":"mine","id":"3608741","name":"Penn View Mine"},"validFrom":"2000-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608741|C13674|2000-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"object":{"type":"operator","id":"P24367","name":"Penn View Mining, Inc."},"validFrom":"2000-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608741","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608741|P24367|2000-02-01|C13674|2000-02-01|90793"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":55,"firstDate":"2000-04-06","lastDate":"2007-12-10","metrics":{"daysLost":862,"injuries":48,"fatalities":0,"recentRows":0,"restrictedDays":556,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"7080","DOCUMENT_NO":"220073550022","ACCIDENT_DT":"12/10/2007","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While employee was performing his normal duties as a working supervisor he experienced pain/swelling in his right knee.  Employee did not miss any work however he was placed on restricted duty on 12/11/2007 and was released for full duty on 12/19/2007.","sourceDate":"2007-12-10"},{"SOURCE_ROW_NUMBER":"166273","DOCUMENT_NO":"220072610014","ACCIDENT_DT":"09/08/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee was grinding a light bracket for on a scoop when he felt something enter his right eye.  Employee was wearing safety glasses when this occurred.","sourceDate":"2007-09-08"},{"SOURCE_ROW_NUMBER":"157615","DOCUMENT_NO":"220072000003","ACCIDENT_DT":"07/11/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was backing scoop up in low coal when he pinched his head between the roof and the seat of the scoop.","sourceDate":"2007-07-11"},{"SOURCE_ROW_NUMBER":"166272","DOCUMENT_NO":"220071780016","ACCIDENT_DT":"06/22/2007","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Barge/Boat/Dredge/Towbarge/Towboat/Leach operator, Riverman, Deck hand","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting belt when the knife slipped thus lacerating left middle finger.Employee did not miss any work however he did receive sutures making this accident reportable.","sourceDate":"2007-06-22"},{"SOURCE_ROW_NUMBER":"84532","DOCUMENT_NO":"220071560008","ACCIDENT_DT":"05/23/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"While employee was performing his normal duties as a working supervisor in low coal, he experienced swelling in his right knee.  Employee missed the next two (2) days of work and returned to full duty on May 29. 2007.","sourceDate":"2007-05-23"},{"SOURCE_ROW_NUMBER":"19963","DOCUMENT_NO":"220071370026","ACCIDENT_DT":"05/10/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"27","NARRATIVE":"While performing his normal duties as a Scoop Operator in low coal the employee experienced pain/swelling in his right knee.","sourceDate":"2007-05-10"},{"SOURCE_ROW_NUMBER":"41426","DOCUMENT_NO":"220071280015","ACCIDENT_DT":"04/30/2007","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Rubbed or abraded","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"While performing his normal duties as a Roof Bolter/MBC Operator in low coal the employee experienced pain/swelling in his left knee.  Employee continued working until May 3, 2007 at which time the employee started missing work thus making this reportable.","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"37204","DOCUMENT_NO":"220070590014","ACCIDENT_DT":"02/21/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Rubbed or abraded","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"While employee was performing his normal duties as a Roof Bolter/MBC Operator in low coal he experienced pain/swelling in his left knee.","sourceDate":"2007-02-21"},{"SOURCE_ROW_NUMBER":"196157","DOCUMENT_NO":"220070160041","ACCIDENT_DT":"12/28/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"98","NARRATIVE":"Employee was operating MBC when he experienced pain in back.  Employee continued working until January 8, 2007 at which time he started missing work due to this accident now making this a lost time accident.","sourceDate":"2006-12-28"},{"SOURCE_ROW_NUMBER":"37203","DOCUMENT_NO":"220070030060","ACCIDENT_DT":"11/22/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping on move with cables when a loop of cable flipped over striking him in the mouth chipping tooth. He continued working and on 12/28/2006 He had dental work done now making this reportable.","sourceDate":"2006-11-22"},{"SOURCE_ROW_NUMBER":"37202","DOCUMENT_NO":"220063240001","ACCIDENT_DT":"11/10/2006","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Rubbed or abraded","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"While performing his normal duties as a working supervisor in low coal employee experienced swelling of the left knee.  Employee continued working until 11/17/2006 at which time the employee started missing work.","sourceDate":"2006-11-10"},{"SOURCE_ROW_NUMBER":"191895","DOCUMENT_NO":"220062680008","ACCIDENT_DT":"09/18/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"12","NARRATIVE":"Employee was attempting to install roof bolt.  He was trying to straighten bolt and guide the bolt to the drill head of bolter so bolter could assist in pushing bolt up into the drill hole when the drill head caught bolt bending the same and caught finger between roof bolt plate and the drill head.","sourceDate":"2006-09-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-03-25","lastDate":"2009-03-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":246,"firstDate":"2000-04-13","lastDate":"2008-10-20","metrics":{"ss":77,"delinquent":234,"recentRows":0,"paidPenalty":22173,"proposedPenalty":22173,"currentAssessment":22173},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"697277","VIOLATION_NO":"8010962","ISSUE_DT":"10/20/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-20"},{"SOURCE_ROW_NUMBER":"697276","VIOLATION_NO":"8010961","ISSUE_DT":"10/20/2008","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-20"},{"SOURCE_ROW_NUMBER":"696582","VIOLATION_NO":"7049507","ISSUE_DT":"02/05/2008","CFR_STANDARD_CD":"75.360(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1900.00","CURRENT_ASSESSMENT_AMT":"1900.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"696581","VIOLATION_NO":"7049506","ISSUE_DT":"02/05/2008","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"696580","VIOLATION_NO":"7049505","ISSUE_DT":"02/05/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"696579","VIOLATION_NO":"7049503","ISSUE_DT":"01/10/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-01-10"},{"SOURCE_ROW_NUMBER":"696578","VIOLATION_NO":"7049501","ISSUE_DT":"10/04/2007","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-10-04"},{"SOURCE_ROW_NUMBER":"695791","VIOLATION_NO":"3692080","ISSUE_DT":"08/21/2007","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-21"},{"SOURCE_ROW_NUMBER":"695792","VIOLATION_NO":"7049113","ISSUE_DT":"07/19/2007","CFR_STANDARD_CD":"75.1502(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-19"},{"SOURCE_ROW_NUMBER":"695790","VIOLATION_NO":"7049110","ISSUE_DT":"04/18/2007","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-18"},{"SOURCE_ROW_NUMBER":"666787","VIOLATION_NO":"3692079","ISSUE_DT":"03/26/2007","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-26"},{"SOURCE_ROW_NUMBER":"666790","VIOLATION_NO":"7063211","ISSUE_DT":"03/13/2007","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":677,"firstDate":"2000-04-17","lastDate":"2009-03-09","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":30,"validSamples":647,"maxConcentration":4.331,"concentrationTotal":591.826},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"748964","CASS_NUM":"57710134","SMP_TAKEN_DT":"3/9/2009","CONC":".014","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-03-09"},{"SOURCE_ROW_NUMBER":"1241053","CASS_NUM":"50890964","SMP_TAKEN_DT":"2/7/2008","CONC":".152","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-07"},{"SOURCE_ROW_NUMBER":"280786","CASS_NUM":"50836610","SMP_TAKEN_DT":"2/7/2008","CONC":".554","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-07"},{"SOURCE_ROW_NUMBER":"100721","CASS_NUM":"50890932","SMP_TAKEN_DT":"2/7/2008","CONC":".606","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-07"},{"SOURCE_ROW_NUMBER":"1465235","CASS_NUM":"50890859","SMP_TAKEN_DT":"2/6/2008","CONC":".766","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"OPERATOR VOID; PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-06"},{"SOURCE_ROW_NUMBER":"1215909","CASS_NUM":"50890951","SMP_TAKEN_DT":"2/6/2008","CONC":".253","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-06"},{"SOURCE_ROW_NUMBER":"1347351","CASS_NUM":"50890933","SMP_TAKEN_DT":"2/5/2008","CONC":".784","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"69324","CASS_NUM":"50923943","SMP_TAKEN_DT":"2/5/2008","CONC":".424","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"1660294","CASS_NUM":"57682278","SMP_TAKEN_DT":"1/22/2008","CONC":".237","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-01-22"},{"SOURCE_ROW_NUMBER":"1397572","CASS_NUM":"57682264","SMP_TAKEN_DT":"1/22/2008","CONC":"1.562","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-01-22"},{"SOURCE_ROW_NUMBER":"1337604","CASS_NUM":"57682274","SMP_TAKEN_DT":"1/22/2008","CONC":".379","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-01-22"},{"SOURCE_ROW_NUMBER":"1310187","CASS_NUM":"57682271","SMP_TAKEN_DT":"1/22/2008","CONC":".764","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-01-22"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":12,"firstDate":"2000-05-26","lastDate":"2008-03-21","metrics":{"linkedIssuances":12},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":57,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1998-06-01","lastDate":"2000-02-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":158,"firstDate":"2000-02-22","lastDate":"2009-03-30","metrics":{"inspectors":209,"recentRows":0,"onSiteHours":3323.25,"inspectionHours":5791.25,"inspectionSamples":174},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147136","EVENT_NO":"4043928","INSPECTION_BEGIN_DT":"03/30/2009","INSPECTION_END_DT":"03/30/2009","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2009-03-30"},{"SOURCE_ROW_NUMBER":"6164","EVENT_NO":"4044306","INSPECTION_BEGIN_DT":"01/05/2009","INSPECTION_END_DT":"03/10/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"22.5","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2009-01-05"},{"SOURCE_ROW_NUMBER":"144902","EVENT_NO":"4044207","INSPECTION_BEGIN_DT":"11/18/2008","INSPECTION_END_DT":"11/18/2008","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2008-11-18"},{"SOURCE_ROW_NUMBER":"850319","EVENT_NO":"4044301","INSPECTION_BEGIN_DT":"10/16/2008","INSPECTION_END_DT":"12/08/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"39.5","SUM_TOTAL_ON_SITE_HOURS":"22","sourceDate":"2008-10-16"},{"SOURCE_ROW_NUMBER":"764871","EVENT_NO":"4043821","INSPECTION_BEGIN_DT":"07/01/2008","INSPECTION_END_DT":"08/12/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2008-07-01"},{"SOURCE_ROW_NUMBER":"253628","EVENT_NO":"4020992","INSPECTION_BEGIN_DT":"06/05/2008","INSPECTION_END_DT":"06/06/2008","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2008-06-05"},{"SOURCE_ROW_NUMBER":"831425","EVENT_NO":"4043814","INSPECTION_BEGIN_DT":"04/01/2008","INSPECTION_END_DT":"05/20/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2008-04-01"},{"SOURCE_ROW_NUMBER":"438320","EVENT_NO":"4043911","INSPECTION_BEGIN_DT":"03/17/2008","INSPECTION_END_DT":"03/18/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5.75","sourceDate":"2008-03-17"},{"SOURCE_ROW_NUMBER":"12316","EVENT_NO":"4043909","INSPECTION_BEGIN_DT":"02/26/2008","INSPECTION_END_DT":"02/26/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2008-02-26"},{"SOURCE_ROW_NUMBER":"244343","EVENT_NO":"4043907","INSPECTION_BEGIN_DT":"01/02/2008","INSPECTION_END_DT":"02/11/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"159.25","SUM_TOTAL_ON_SITE_HOURS":"98.5","sourceDate":"2008-01-02"},{"SOURCE_ROW_NUMBER":"910075","EVENT_NO":"4020970","INSPECTION_BEGIN_DT":"11/23/2007","INSPECTION_END_DT":"12/20/2007","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2007-11-23"},{"SOURCE_ROW_NUMBER":"927534","EVENT_NO":"4043905","INSPECTION_BEGIN_DT":"10/01/2007","INSPECTION_END_DT":"11/05/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"156","SUM_TOTAL_ON_SITE_HOURS":"107","sourceDate":"2007-10-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":74,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009-Q1":{"hours":76,"employees":1,"production":0},"2008-Q4":{"hours":362,"employees":1,"production":0},"2008-Q3":{"hours":184,"employees":1,"production":0},"2008-Q2":{"hours":180,"employees":3,"production":0},"2008-Q1":{"hours":11398,"employees":22,"production":75047},"2007-Q4":{"hours":12656,"employees":24,"production":81369},"2007-Q3":{"hours":12314,"employees":24,"production":77073},"2007-Q2":{"hours":12230,"employees":24,"production":83080},"2007-Q1":{"hours":12904,"employees":24,"production":91428},"2006-Q4":{"hours":12196,"employees":22,"production":80301},"2006-Q3":{"hours":11179,"employees":22,"production":80139},"2006-Q2":{"hours":12313,"employees":22,"production":91407}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":19,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":13943,"employees":8,"production":72198},"2001":{"hours":38802,"employees":17,"production":181166},"2002":{"hours":44316,"employees":22,"production":179183},"2003":{"hours":47658,"employees":22,"production":254225},"2004":{"hours":49602,"employees":27,"production":291089},"2005":{"hours":51317,"employees":22,"production":376732},"2006":{"hours":48567,"employees":22,"production":348981},"2007":{"hours":50104,"employees":24,"production":332950},"2008":{"hours":12124,"employees":22,"production":75047},"2009":{"hours":76,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":66,"firstDate":"2000-04-19","lastDate":"2009-03-09","metrics":{"recentRows":0,"doseOver100":24,"actDoseTotal":5485,"pelDoseTotal":4200},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"163163","EVENT_NO":"4044306","SURVEY_DATE":"03/09/2009","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"58","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2009-03-09"},{"SOURCE_ROW_NUMBER":"163162","EVENT_NO":"4043905","SURVEY_DATE":"10/17/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"75","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2007-10-17"},{"SOURCE_ROW_NUMBER":"163161","EVENT_NO":"4043905","SURVEY_DATE":"10/17/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"124","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2007-10-17"},{"SOURCE_ROW_NUMBER":"163160","EVENT_NO":"4043905","SURVEY_DATE":"10/17/2007","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"056","ACT_DOSE_85":"61","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2007-10-17"},{"SOURCE_ROW_NUMBER":"163159","EVENT_NO":"4043905","SURVEY_DATE":"10/17/2007","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"056","ACT_DOSE_85":"80","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2007-10-17"},{"SOURCE_ROW_NUMBER":"163158","EVENT_NO":"4043905","SURVEY_DATE":"10/17/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"056","ACT_DOSE_85":"92","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2007-10-17"},{"SOURCE_ROW_NUMBER":"163157","EVENT_NO":"4043905","SURVEY_DATE":"10/11/2007","OCCUPATION_CD_DESC":"FORKLIFT OPERATOR","MACHINE_CD":"17","MANUFACTURER_CD":"018","ACT_DOSE_85":"20","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2007-10-11"},{"SOURCE_ROW_NUMBER":"163156","EVENT_NO":"4043905","SURVEY_DATE":"10/11/2007","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2007-10-11"},{"SOURCE_ROW_NUMBER":"163140","EVENT_NO":"4020949","SURVEY_DATE":"03/28/2007","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"18","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2007-03-28"},{"SOURCE_ROW_NUMBER":"163139","EVENT_NO":"4020949","SURVEY_DATE":"03/28/2007","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"30","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2007-03-28"},{"SOURCE_ROW_NUMBER":"163138","EVENT_NO":"4020949","SURVEY_DATE":"03/26/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"056","ACT_DOSE_85":"104","PEL_DOSE_90":"88","SURVEY_TYPE":"F","sourceDate":"2007-03-26"},{"SOURCE_ROW_NUMBER":"163137","EVENT_NO":"4020949","SURVEY_DATE":"03/21/2007","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"056","ACT_DOSE_85":"111","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2007-03-21"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":48,"firstDate":"2000-05-02","lastDate":"2008-01-22","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":16,"validSamples":48,"quartzPctTotal":106},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"97560","CASSETTE_NO":"57682246","SAMPLE_DT":"01/22/2008","QUARTZ_PCT":"02.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-01-22"},{"SOURCE_ROW_NUMBER":"154219","CASSETTE_NO":"57681721","SAMPLE_DT":"07/18/2007","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-07-18"},{"SOURCE_ROW_NUMBER":"105628","CASSETTE_NO":"57525088","SAMPLE_DT":"08/14/2006","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-08-14"},{"SOURCE_ROW_NUMBER":"88670","CASSETTE_NO":"57571161","SAMPLE_DT":"07/11/2006","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-07-11"},{"SOURCE_ROW_NUMBER":"42866","CASSETTE_NO":"57525080","SAMPLE_DT":"06/21/2006","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-21"},{"SOURCE_ROW_NUMBER":"24327","CASSETTE_NO":"57506460","SAMPLE_DT":"11/08/2005","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-08"},{"SOURCE_ROW_NUMBER":"108764","CASSETTE_NO":"57515441","SAMPLE_DT":"08/23/2005","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-23"},{"SOURCE_ROW_NUMBER":"119566","CASSETTE_NO":"57515546","SAMPLE_DT":"07/06/2005","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-07-06"},{"SOURCE_ROW_NUMBER":"142085","CASSETTE_NO":"57515408","SAMPLE_DT":"04/07/2005","QUARTZ_PCT":"01.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-07"},{"SOURCE_ROW_NUMBER":"148185","CASSETTE_NO":"57598955","SAMPLE_DT":"02/16/2005","QUARTZ_PCT":"01.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-16"},{"SOURCE_ROW_NUMBER":"81194","CASSETTE_NO":"57598942","SAMPLE_DT":"02/16/2005","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-16"},{"SOURCE_ROW_NUMBER":"77902","CASSETTE_NO":"57599027","SAMPLE_DT":"12/06/2004","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-12-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":250,"firstDate":"2000-04-13","lastDate":"2008-10-20","metrics":{"ss":77,"amountDue":22173,"contested":0,"amountPaid":22173,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":22173},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1953649","VIOLATION_NO":"8010962","VIOLATION_ISSUE_DT":"10/20/2008","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/20/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-20"},{"SOURCE_ROW_NUMBER":"1953648","VIOLATION_NO":"8010961","VIOLATION_ISSUE_DT":"10/20/2008","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/20/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-20"},{"SOURCE_ROW_NUMBER":"1953429","VIOLATION_NO":"7049507","VIOLATION_ISSUE_DT":"02/05/2008","SIG_SUB":"N","PART_SECTION":"75.360(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"7","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"02/05/2008","PROPOSED_PENALTY":"1900","AMOUNT_DUE":"1900","AMOUNT_PAID":"1900","CONTESTED_IND":"N","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"1953428","VIOLATION_NO":"7049506","VIOLATION_ISSUE_DT":"02/05/2008","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/05/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"1953427","VIOLATION_NO":"7049505","VIOLATION_ISSUE_DT":"02/05/2008","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/05/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"1953426","VIOLATION_NO":"7049503","VIOLATION_ISSUE_DT":"01/10/2008","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/10/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-01-10"},{"SOURCE_ROW_NUMBER":"1953605","VIOLATION_NO":"7049501","VIOLATION_ISSUE_DT":"10/04/2007","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/04/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-10-04"},{"SOURCE_ROW_NUMBER":"1953570","VIOLATION_NO":"3692080","VIOLATION_ISSUE_DT":"08/21/2007","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/21/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-08-21"},{"SOURCE_ROW_NUMBER":"1953571","VIOLATION_NO":"7049113","VIOLATION_ISSUE_DT":"07/19/2007","SIG_SUB":"N","PART_SECTION":"75.1502(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"22","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-07-19"},{"SOURCE_ROW_NUMBER":"1953494","VIOLATION_NO":"7049110","VIOLATION_ISSUE_DT":"04/18/2007","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/18/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-04-18"},{"SOURCE_ROW_NUMBER":"1953493","VIOLATION_NO":"7049109","VIOLATION_ISSUE_DT":"04/05/2007","PART_SECTION":"75.1403-10(c)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"04/05/2007","CONTESTED_IND":"N","sourceDate":"2007-04-05"},{"SOURCE_ROW_NUMBER":"1953440","VIOLATION_NO":"3692079","VIOLATION_ISSUE_DT":"03/26/2007","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/26/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-03-26"}]}],"safety":{"href":"/api/v1/mines/3608741/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608741/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","heading":"Mine emergency evacuation and firefighting program of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1502","part":"75","subchapter":"O","subpart":"P","id":"75.1502","citation":"30 CFR 75.1502","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-10","heading":"Criteria—Haulage; general.","id":"75.1403-10","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-10","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) A permissible trip light or other approved device such as reflectors, approved by the Coal Mine Safety District Manager(s), should be used on the rear of trips pulled, on the front of trips pushed and on trips lowered in slopes. However, trip lights or other approved devices need not be used on cars being shifted to and from loading machines, on cars being handled at loading heads, during gathering operations at working faces, when trailing locomotives are used, or on trips pulled by animals.\n\n(b) Cars on main haulage roads should not be pushed, except where necessary to push cars from side tracks located near the working section to the producing entries and rooms, where necessary to clear switches and sidetracks, and on the approach to cages, slopes, and surface inclines.\n\n(c) Warning lights or reflective signs or tapes should be installed along haulage roads at locations of abrupt or sudden changes in the overhead clearance.\n\n(d) No person, other than the motorman and brakeman, should ride on a locomotive unless authorized by the mine foreman, and then only when safe riding facilities are provided. No person should ride on any loaded car or on the bumper of any car. However, the brakeman may ride on the rear bumper of the last car of a slow moving trip pulled by a locomotive.\n\n(e) Positive-acting stopblocks or derails should be used where necessary to protect persons from danger of runaway haulage equipment.\n\n(f) An audible warning should be given by the operator of all self-propelled equipment including off-track equipment, where persons may be endangered by the movement of the equipment.\n\n(g) Locomotives and personnel carriers should not approach to within 300 feet of preceding haulage equipment, except trailing locomotives that are an integral part of the trip.\n\n(h) A total of at least 36 inches of unobstructed side clearance (both sides combined) should be provided for all rubber-tired haulage equipment where such equipment is used.\n\n(i) Off-track haulage roadways should be maintained as free as practicable from bottom irregularities, debris, and wet or muddy conditions that affect the control of the equipment.\n\n(j) Operators of self-propelled equipment should face in the direction of travel.\n\n(k) Mechanical steering and control devices should be maintained so as to provide positive control at all times.\n\n(l) All self-propelled rubber-tired haulage equipment should be equipped with well maintained brakes, lights, and a warning device.\n\n(m) On and after March 30, 1971, all tram control switches on rubber-tired equipment should be designed to provide automatic return to the stop or off position when released.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608741","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}