{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3608704","name":"Hamilton Shop","status":"Abandoned","status_date":"2017-04-07","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Jefferson","nearest_town":"Hamilton","operator_id":"P09635","operator_name":"Rosebud Mining Company","controller_id":"C07485","controller_name":"J Clifford  Forrest III","district":"M2","office":"Clearfield PA Field Office","employees":0,"latitude":40.920278,"longitude":-79.079722},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":3815},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"operator":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"controller":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"1979-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|C07485|1979-08-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07727","name":"Kerry L  Mears"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"1980-01-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|C07727|1980-01-31|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C10919","name":"Stanford Energy"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"1983-07-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|C10919|1983-07-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17492","name":"Doverspike Brothers Coal Company"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"1997-11-01","validTo":"1999-06-24","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P17492|1997-11-01|1999-06-24"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C10919","name":"Stanford Energy"},"object":{"type":"operator","id":"P17492","name":"Doverspike Brothers Coal Company"},"validFrom":"1997-11-01","validTo":"1999-06-24","current":false,"derived":true,"evidenceMineId":"3608704","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P17492|1997-11-01|C10919|1983-07-01|83136"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15854","name":"Marvin D  Phillips Jr"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"1999-04-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|C15854|1999-04-05|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24256","name":"Anita Mining Company"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"1999-06-25","validTo":"2002-04-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P24256|1999-06-25|2002-04-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15854","name":"Marvin D  Phillips Jr"},"object":{"type":"operator","id":"P24256","name":"Anita Mining Company"},"validFrom":"1999-06-25","validTo":"2002-04-30","current":false,"derived":true,"evidenceMineId":"3608704","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P24256|1999-06-25|C15854|1999-04-05|97114"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P10041","name":"Mears Enterprises Inc."},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"2002-05-01","validTo":"2003-11-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P10041|2002-05-01|2003-11-16"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07727","name":"Kerry L  Mears"},"object":{"type":"operator","id":"P10041","name":"Mears Enterprises Inc."},"validFrom":"2002-05-01","validTo":"2003-11-16","current":false,"derived":true,"evidenceMineId":"3608704","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P10041|2002-05-01|C07727|1980-01-31|75541"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"2003-03-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|0041211|2003-03-11|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051231","name":"AMFIRE Mining Company LLC"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"2003-11-17","validTo":"2014-12-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|0051231|2003-11-17|2014-12-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0051231","name":"AMFIRE Mining Company LLC"},"validFrom":"2003-11-17","validTo":"2014-12-29","current":false,"derived":true,"evidenceMineId":"3608704","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|0051231|2003-11-17|0041211|2003-03-11|1703"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"object":{"type":"mine","id":"3608704","name":"Hamilton Shop"},"validFrom":"2014-12-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P09635|2014-12-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07485","name":"J Clifford  Forrest III"},"object":{"type":"operator","id":"P09635","name":"Rosebud Mining Company"},"validFrom":"2014-12-30","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608704","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608704|P09635|2014-12-30|C07485|1979-08-01|74774"}}],"coverage":{"historyRecords":5,"edgeCount":15,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":94,"firstDate":"2002-01-11","lastDate":"2012-07-16","metrics":{"daysLost":2315,"injuries":70,"fatalities":0,"recentRows":0,"restrictedDays":169,"contractorRecords":9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"161916","DOCUMENT_NO":"220122000037","ACCIDENT_DT":"07/16/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using a rock bar to scale down a piece of sand rock when the rock shifted allowing the bar to suddenly rise up and strike the employee in the mouth causing a laceration of the lower lip requiring 3 sutures.","sourceDate":"2012-07-16"},{"SOURCE_ROW_NUMBER":"105719","DOCUMENT_NO":"220121500030","ACCIDENT_DT":"05/24/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof Fall on #3 Entry of 2-Southwest Section. Roof supported with 6-foot FG Resin Bolts and various lengths of cable bolts (10' - 12' - 16'). Ventilation was not disrupted. Slicken-sided roof was noted in the stack rock produced during the fall.","sourceDate":"2012-05-24"},{"SOURCE_ROW_NUMBER":"183461","DOCUMENT_NO":"220121290018","ACCIDENT_DT":"05/03/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Unloading airlock doors off of a skid when the doors slid pinching his finger causing a fracture that required surgery to repair. Employee was wearing metacarpal gloves.","sourceDate":"2012-05-03"},{"SOURCE_ROW_NUMBER":"153309","DOCUMENT_NO":"220120820007","ACCIDENT_DT":"03/19/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall was discovered by an examiner in the #2 entry of 6-Butt LT in the #2 Entry 800 feet outby the active 2-Southwest section. The fall measured 50-feet x 18-20 feet x 8-10 feet high. The roof was supported with 4-foot FG Resin Bolts on 4-Foot Centers.","sourceDate":"2012-03-19"},{"SOURCE_ROW_NUMBER":"71486","DOCUMENT_NO":"220120610018","ACCIDENT_DT":"02/29/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A 40-foot long x 18-feet wide x 10-foot high roof fall occurred in the #3 Belt Entry of the 7-Butt Section outby the working section. The area had been supported with 4-foot FG Roof resin Bolts. A contributing factor may have been slicken-sided roof rock.","sourceDate":"2012-02-29"},{"SOURCE_ROW_NUMBER":"11415","DOCUMENT_NO":"220120240024","ACCIDENT_DT":"01/22/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While removing the outer rubber cable jacket, the razor knife slipped cutting the top of his left hand.","sourceDate":"2012-01-22"},{"SOURCE_ROW_NUMBER":"131612","DOCUMENT_NO":"220120230072","ACCIDENT_DT":"01/18/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","DAYS_LOST":"363","NARRATIVE":"Injured was driving a battery mantrip down the road toward the mine entrance when his brakes failed and the mantrip struck a utility pole.","sourceDate":"2012-01-18"},{"SOURCE_ROW_NUMBER":"256577","DOCUMENT_NO":"220113620010","ACCIDENT_DT":"12/20/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured claims that, while setting cribs, he strained his lower back while moving a rock lying on the bottom.","sourceDate":"2011-12-20"},{"SOURCE_ROW_NUMBER":"54310","DOCUMENT_NO":"220113530027","ACCIDENT_DT":"12/16/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A 30-foot long x 18-20-foot wide x approximately 6-foot high roof fall occurred in the # 5 entry of 7-Butt Section at the face and last intersection. The area was supported with both 4-foot and 6-foot fully-grouted resin bolts. The section was experiencing roof water. The cave will not be cleaned up. No equipment or ventilation affected.","sourceDate":"2011-12-16"},{"SOURCE_ROW_NUMBER":"204869","DOCUMENT_NO":"220113530029","ACCIDENT_DT":"11/07/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"159","NARRATIVE":"While installing a 6-foot resin bolt and spon straightening out the second bend in the bolt, employee states that he felt pain and heard a pop in his right arm. Employee worked his regular job until 12/14/2011 when he went to the doctor for a follow-up visit and was restricted from working. First day missed was 12/14/2011.","sourceDate":"2011-11-07"},{"SOURCE_ROW_NUMBER":"213561","DOCUMENT_NO":"220113050005","ACCIDENT_DT":"10/28/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"68","NARRATIVE":"Employee was roof bolting when a rock fell from between bolts and struck him on the left lower leg.","sourceDate":"2011-10-28"},{"SOURCE_ROW_NUMBER":"153308","DOCUMENT_NO":"220113320002","ACCIDENT_DT":"10/17/2011","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Rubbed or abraded","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"Employee developed patella bursitis and superficial cellulites of the left knee from repetitive motion of crawling. He was first seen by a doctor on 11/21/2011 and placed on restricted duty.","sourceDate":"2011-10-17"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-04-07","lastDate":"2017-04-07","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":499,"firstDate":"2000-09-28","lastDate":"2013-07-08","metrics":{"ss":194,"delinquent":487,"recentRows":0,"paidPenalty":230944,"proposedPenalty":394535,"currentAssessment":230944},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1663311","VIOLATION_NO":"7040854","ISSUE_DT":"07/08/2013","CFR_STANDARD_CD":"75.808","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"1663312","VIOLATION_NO":"7040856","ISSUE_DT":"07/03/2013","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"900.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-03"},{"SOURCE_ROW_NUMBER":"695169","VIOLATION_NO":"8006330","ISSUE_DT":"03/06/2013","CFR_STANDARD_CD":"75.312(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"695168","VIOLATION_NO":"8006329","ISSUE_DT":"12/20/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-20"},{"SOURCE_ROW_NUMBER":"695167","VIOLATION_NO":"8006327","ISSUE_DT":"12/06/2012","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-06"},{"SOURCE_ROW_NUMBER":"695166","VIOLATION_NO":"8006326","ISSUE_DT":"11/02/2012","CFR_STANDARD_CD":"75.310(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1111.00","CURRENT_ASSESSMENT_AMT":"1111.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-02"},{"SOURCE_ROW_NUMBER":"697978","VIOLATION_NO":"7040712","ISSUE_DT":"09/10/2012","CFR_STANDARD_CD":"75.1504(d)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"697977","VIOLATION_NO":"7040711","ISSUE_DT":"09/05/2012","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"697979","VIOLATION_NO":"8006372","ISSUE_DT":"09/04/2012","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-04"},{"SOURCE_ROW_NUMBER":"697976","VIOLATION_NO":"7040710","ISSUE_DT":"08/28/2012","CFR_STANDARD_CD":"75.1107-16(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-28"},{"SOURCE_ROW_NUMBER":"697975","VIOLATION_NO":"7040705","ISSUE_DT":"07/27/2012","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-27"},{"SOURCE_ROW_NUMBER":"697987","VIOLATION_NO":"8006429","ISSUE_DT":"07/26/2012","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-26"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":117,"firstDate":"2003-07-15","lastDate":"2015-03-20","metrics":{"appeals":0,"decisions":117,"recentRows":0,"decisionPenalty":185136,"originalPenalty":422138},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"350589","VIOLATION_NO":"7040854","DOCKET_NO":"PENN 2014-18","DECISION_DT":"03/20/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-03-20"},{"SOURCE_ROW_NUMBER":"350208","VIOLATION_NO":"7040856","DOCKET_NO":"PENN 2014-18","DECISION_DT":"03/20/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"900.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2015-03-20"},{"SOURCE_ROW_NUMBER":"344086","VIOLATION_NO":"8006331","DOCKET_NO":"PENN 2013-245","DECISION_DT":"01/22/2014","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2014-01-22"},{"SOURCE_ROW_NUMBER":"331847","VIOLATION_NO":"7021835","DOCKET_NO":"PENN 2012-422","DECISION_DT":"11/20/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"20000.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-20"},{"SOURCE_ROW_NUMBER":"91297","VIOLATION_NO":"8013977","DOCKET_NO":"PENN 2012-427","DECISION_DT":"11/20/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":"5000.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-20"},{"SOURCE_ROW_NUMBER":"91090","VIOLATION_NO":"8013979","DOCKET_NO":"PENN 2012-426","DECISION_DT":"11/20/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3400.00","DECISION_PENALTY_AMT":"2700.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-11-20"},{"SOURCE_ROW_NUMBER":"332109","VIOLATION_NO":"8013899","DOCKET_NO":"PENN 2012-425","DECISION_DT":"08/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"650.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-08-29"},{"SOURCE_ROW_NUMBER":"330539","VIOLATION_NO":"7021876","DOCKET_NO":"PENN 2012-393","DECISION_DT":"08/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"41574.00","DECISION_PENALTY_AMT":"35000.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-08-29"},{"SOURCE_ROW_NUMBER":"94780","VIOLATION_NO":"7021877","DOCKET_NO":"PENN 2013-114","DECISION_DT":"08/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"41574.00","DECISION_PENALTY_AMT":"25000.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-08-29"},{"SOURCE_ROW_NUMBER":"91298","VIOLATION_NO":"7021854","DOCKET_NO":"PENN 2012-428","DECISION_DT":"08/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"36750.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-08-29"},{"SOURCE_ROW_NUMBER":"70048","VIOLATION_NO":"8012006","DOCKET_NO":"PENN 2011-441","DECISION_DT":"07/03/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4329.00","DECISION_PENALTY_AMT":"3100.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2013-07-03"},{"SOURCE_ROW_NUMBER":"333307","VIOLATION_NO":"8013978","DOCKET_NO":"PENN 2012-419","DECISION_DT":"06/13/2013","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Kenneth","JUDGE_LAST_NAME":"Andrews","sourceDate":"2013-06-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1024,"firstDate":"2002-01-29","lastDate":"2014-06-24","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":48,"validSamples":976,"maxConcentration":56.538,"concentrationTotal":833.688},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1213972","CASS_NUM":"58144586","SMP_TAKEN_DT":"6/24/2014","CONC":".025","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"1097865","CASS_NUM":"58144343","SMP_TAKEN_DT":"6/24/2014","CONC":".028","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"825075","CASS_NUM":"57984929","SMP_TAKEN_DT":"12/3/2012","CONC":".07","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-12-03"},{"SOURCE_ROW_NUMBER":"1043611","CASS_NUM":"57984979","SMP_TAKEN_DT":"9/11/2012","CONC":".962","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"999805","CASS_NUM":"57984860","SMP_TAKEN_DT":"9/11/2012","CONC":".203","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"888654","CASS_NUM":"57984957","SMP_TAKEN_DT":"9/11/2012","CONC":"1.254","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"852381","CASS_NUM":"57984943","SMP_TAKEN_DT":"9/11/2012","CONC":".233","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"524769","CASS_NUM":"57984964","SMP_TAKEN_DT":"9/11/2012","CONC":".081","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"483395","CASS_NUM":"57985018","SMP_TAKEN_DT":"9/11/2012","CONC":"1.071","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"339419","CASS_NUM":"57985072","SMP_TAKEN_DT":"9/11/2012","CONC":".234","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"17430","CASS_NUM":"57984944","SMP_TAKEN_DT":"9/11/2012","CONC":"1.626","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"1203259","CASS_NUM":"51188185","SMP_TAKEN_DT":"9/7/2012","CONC":".748","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":44,"firstDate":"2002-04-16","lastDate":"2013-11-20","metrics":{"linkedIssuances":44},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":89,"firstDate":"2004-07-14","lastDate":"2013-07-08","metrics":{"decisions":89,"ssChanged":28,"recentRows":0,"decisionPenalty":182316,"proposedPenalty":419017},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"31432","CITATION_NO":"7040854","CITATION_ISSUE_DT":"07/08/2013","DOCKET_NO":"PENN 2014-18","DECISION_DT":"03/20/2015","CFR_STANDARD_CODE":"75.808","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"315717","CITATION_NO":"7040856","CITATION_ISSUE_DT":"07/03/2013","DOCKET_NO":"PENN 2014-18","DECISION_DT":"03/20/2015","CFR_STANDARD_CODE":"77.502","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"900.00","sourceDate":"2013-07-03"},{"SOURCE_ROW_NUMBER":"35448","CITATION_NO":"8006331","CITATION_ISSUE_DT":"03/06/2013","DOCKET_NO":"PENN 2013-245","DECISION_DT":"01/22/2014","CFR_STANDARD_CODE":"77.903","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":".00","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"147888","CITATION_NO":"8006425","CITATION_ISSUE_DT":"07/26/2012","DOCKET_NO":"PENN 2012-429","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.516-2(c)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":".00","sourceDate":"2012-07-26"},{"SOURCE_ROW_NUMBER":"261230","CITATION_NO":"8006423","CITATION_ISSUE_DT":"07/25/2012","DOCKET_NO":"PENN 2012-429","DECISION_DT":"02/12/2013","CFR_STANDARD_CODE":"75.515","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"243.00","sourceDate":"2012-07-25"},{"SOURCE_ROW_NUMBER":"258055","CITATION_NO":"7021876","CITATION_ISSUE_DT":"05/31/2012","DOCKET_NO":"PENN 2012-393","DECISION_DT":"08/29/2013","CFR_STANDARD_CODE":"75.380(d)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"41574.00","DECISION_PENALTY_AMT":"35000.00","sourceDate":"2012-05-31"},{"SOURCE_ROW_NUMBER":"201702","CITATION_NO":"7021877","CITATION_ISSUE_DT":"05/31/2012","DOCKET_NO":"PENN 2013-114","DECISION_DT":"08/29/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"41574.00","DECISION_PENALTY_AMT":"25000.00","sourceDate":"2012-05-31"},{"SOURCE_ROW_NUMBER":"312758","CITATION_NO":"8013899","CITATION_ISSUE_DT":"02/08/2012","DOCKET_NO":"PENN 2012-425","DECISION_DT":"08/29/2013","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"650.00","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"429272","CITATION_NO":"7021835","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"PENN 2012-422","DECISION_DT":"11/20/2013","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"52500.00","DECISION_PENALTY_AMT":"20000.00","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"340179","CITATION_NO":"8013977","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"PENN 2012-427","DECISION_DT":"11/20/2013","CFR_STANDARD_CODE":"50.10(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":"5000.00","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"170578","CITATION_NO":"8013978","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"PENN 2012-419","DECISION_DT":"06/13/2013","CFR_STANDARD_CODE":"50.10(b)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":".00","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"58319","CITATION_NO":"8013979","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"PENN 2012-426","DECISION_DT":"11/20/2013","CFR_STANDARD_CODE":"50.12","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"3400.00","DECISION_PENALTY_AMT":"2700.00","sourceDate":"2012-01-23"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":688,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":147,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"1997-11-01","lastDate":"2014-12-30","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":4},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":265,"firstDate":"2000-03-29","lastDate":"2017-03-07","metrics":{"inspectors":409,"recentRows":0,"onSiteHours":7737.75,"inspectionHours":12961,"inspectionSamples":629},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"514327","EVENT_NO":"6243693","INSPECTION_BEGIN_DT":"03/07/2017","INSPECTION_END_DT":"03/07/2017","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2017-03-07"},{"SOURCE_ROW_NUMBER":"341100","EVENT_NO":"6243405","INSPECTION_BEGIN_DT":"09/13/2016","INSPECTION_END_DT":"09/13/2016","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2016-09-13"},{"SOURCE_ROW_NUMBER":"575841","EVENT_NO":"6243188","INSPECTION_BEGIN_DT":"03/14/2016","INSPECTION_END_DT":"03/14/2016","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2016-03-14"},{"SOURCE_ROW_NUMBER":"552455","EVENT_NO":"4049893","INSPECTION_BEGIN_DT":"06/17/2015","INSPECTION_END_DT":"06/17/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2015-06-17"},{"SOURCE_ROW_NUMBER":"269017","EVENT_NO":"6243101","INSPECTION_BEGIN_DT":"03/04/2015","INSPECTION_END_DT":"03/04/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2015-03-04"},{"SOURCE_ROW_NUMBER":"259607","EVENT_NO":"6243012","INSPECTION_BEGIN_DT":"06/24/2014","INSPECTION_END_DT":"06/24/2014","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"471368","EVENT_NO":"6242922","INSPECTION_BEGIN_DT":"04/14/2014","INSPECTION_END_DT":"04/15/2014","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2014-04-14"},{"SOURCE_ROW_NUMBER":"738763","EVENT_NO":"6242819","INSPECTION_BEGIN_DT":"04/02/2014","INSPECTION_END_DT":"06/10/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"62","SUM_TOTAL_ON_SITE_HOURS":"28.5","sourceDate":"2014-04-02"},{"SOURCE_ROW_NUMBER":"3446","EVENT_NO":"6242902","INSPECTION_BEGIN_DT":"01/02/2014","INSPECTION_END_DT":"03/10/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"31.5","SUM_TOTAL_ON_SITE_HOURS":"19.5","sourceDate":"2014-01-02"},{"SOURCE_ROW_NUMBER":"1023824","EVENT_NO":"6242071","INSPECTION_BEGIN_DT":"10/17/2013","INSPECTION_END_DT":"12/19/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"39.25","SUM_TOTAL_ON_SITE_HOURS":"20.75","sourceDate":"2013-10-17"},{"SOURCE_ROW_NUMBER":"603367","EVENT_NO":"6242067","INSPECTION_BEGIN_DT":"10/08/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-10-08"},{"SOURCE_ROW_NUMBER":"62602","EVENT_NO":"6242283","INSPECTION_BEGIN_DT":"09/19/2013","INSPECTION_END_DT":"09/25/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2013-09-19"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":123,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q1":{"hours":0,"employees":0,"production":0},"2016-Q4":{"hours":0,"employees":0,"production":0},"2016-Q3":{"hours":0,"employees":0,"production":0},"2015-Q1":{"hours":0,"employees":0,"production":0},"2014-Q4":{"hours":904,"employees":2,"production":0},"2014-Q3":{"hours":1306,"employees":2,"production":0},"2014-Q2":{"hours":1676,"employees":4,"production":0},"2014-Q1":{"hours":1785,"employees":3,"production":0},"2013-Q4":{"hours":1604,"employees":3,"production":0},"2013-Q3":{"hours":1588,"employees":3,"production":0},"2013-Q2":{"hours":1749,"employees":3,"production":0},"2013-Q1":{"hours":1791,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":29,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":77843,"employees":31,"production":168633},"2006":{"hours":91329,"employees":35,"production":185117},"2007":{"hours":87651,"employees":35,"production":161920},"2008":{"hours":85858,"employees":35,"production":157051},"2009":{"hours":77690,"employees":35,"production":138607},"2010":{"hours":96607,"employees":39,"production":173511},"2011":{"hours":100851,"employees":41,"production":129104},"2012":{"hours":84933,"employees":38,"production":54749},"2013":{"hours":6732,"employees":3,"production":0},"2014":{"hours":5671,"employees":6,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":112,"firstDate":"2002-05-01","lastDate":"2014-06-24","metrics":{"recentRows":0,"doseOver100":21,"actDoseTotal":7652,"pelDoseTotal":5659},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"162651","EVENT_NO":"6243012","SURVEY_DATE":"06/24/2014","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"12","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"162650","EVENT_NO":"6243012","SURVEY_DATE":"06/24/2014","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"13","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2014-06-24"},{"SOURCE_ROW_NUMBER":"162570","EVENT_NO":"4042574","SURVEY_DATE":"12/05/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2012-12-05"},{"SOURCE_ROW_NUMBER":"162607","EVENT_NO":"4044367","SURVEY_DATE":"12/12/2011","OCCUPATION_CD_DESC":"FORKLIFT OPERATOR","MACHINE_CD":"17","MANUFACTURER_CD":"018","ACT_DOSE_85":"23","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"162606","EVENT_NO":"4044367","SURVEY_DATE":"12/12/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"14","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2011-12-12"},{"SOURCE_ROW_NUMBER":"162614","EVENT_NO":"4044367","SURVEY_DATE":"12/01/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"37","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2011-12-01"},{"SOURCE_ROW_NUMBER":"162613","EVENT_NO":"4044367","SURVEY_DATE":"12/01/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"36","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2011-12-01"},{"SOURCE_ROW_NUMBER":"162612","EVENT_NO":"4044367","SURVEY_DATE":"11/29/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"91","PEL_DOSE_90":"71","SURVEY_TYPE":"I","sourceDate":"2011-11-29"},{"SOURCE_ROW_NUMBER":"162611","EVENT_NO":"4044367","SURVEY_DATE":"11/29/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"63","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2011-11-29"},{"SOURCE_ROW_NUMBER":"162610","EVENT_NO":"4044367","SURVEY_DATE":"11/29/2011","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"47","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2011-11-29"},{"SOURCE_ROW_NUMBER":"162609","EVENT_NO":"4044367","SURVEY_DATE":"11/29/2011","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"39","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2011-11-29"},{"SOURCE_ROW_NUMBER":"162608","EVENT_NO":"4044367","SURVEY_DATE":"11/29/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2011-11-29"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":63,"firstDate":"2002-01-29","lastDate":"2012-09-11","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":15,"validSamples":61,"quartzPctTotal":247.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"37441","CASSETTE_NO":"57984957","SAMPLE_DT":"09/11/2012","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"103530","CASSETTE_NO":"51203122","SAMPLE_DT":"08/06/2012","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-08-06"},{"SOURCE_ROW_NUMBER":"62125","CASSETTE_NO":"51203220","SAMPLE_DT":"08/06/2012","QUARTZ_PCT":"07.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-08-06"},{"SOURCE_ROW_NUMBER":"76981","CASSETTE_NO":"51203310","SAMPLE_DT":"07/12/2012","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-07-12"},{"SOURCE_ROW_NUMBER":"33369","CASSETTE_NO":"51203306","SAMPLE_DT":"07/12/2012","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-07-12"},{"SOURCE_ROW_NUMBER":"135884","CASSETTE_NO":"57933268","SAMPLE_DT":"06/21/2012","QUARTZ_PCT":"15.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"30000","CASSETTE_NO":"57933283","SAMPLE_DT":"06/21/2012","QUARTZ_PCT":"13.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"50241","CASSETTE_NO":"57933373","SAMPLE_DT":"03/08/2012","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-08"},{"SOURCE_ROW_NUMBER":"84212","CASSETTE_NO":"57955429","SAMPLE_DT":"11/17/2011","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-17"},{"SOURCE_ROW_NUMBER":"51016","CASSETTE_NO":"57921532","SAMPLE_DT":"09/09/2011","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-09"},{"SOURCE_ROW_NUMBER":"21638","CASSETTE_NO":"57870678","SAMPLE_DT":"10/15/2010","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-15"},{"SOURCE_ROW_NUMBER":"118765","CASSETTE_NO":"57772885","SAMPLE_DT":"02/04/2010","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-04"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":514,"firstDate":"2000-09-28","lastDate":"2013-07-08","metrics":{"ss":195,"amountDue":230944,"contested":98,"amountPaid":230944,"recentRows":0,"section104d":9,"unterminated":1,"proposedPenalty":394535},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1951588","VIOLATION_NO":"7040854","VIOLATION_ISSUE_DT":"07/08/2013","SIG_SUB":"N","PART_SECTION":"75.808","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/08/2013","PROPOSED_PENALTY":"224","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-07-08"},{"SOURCE_ROW_NUMBER":"1951589","VIOLATION_NO":"7040856","VIOLATION_ISSUE_DT":"07/03/2013","SIG_SUB":"Y","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/03/2013","PROPOSED_PENALTY":"1111","AMOUNT_DUE":"900","AMOUNT_PAID":"900","CONTESTED_IND":"N","sourceDate":"2013-07-03"},{"SOURCE_ROW_NUMBER":"1951360","VIOLATION_NO":"8006330","VIOLATION_ISSUE_DT":"03/06/2013","SIG_SUB":"N","PART_SECTION":"75.312(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/06/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"1951792","VIOLATION_NO":"8006329","VIOLATION_ISSUE_DT":"12/20/2012","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2013","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2012-12-20"},{"SOURCE_ROW_NUMBER":"1951789","VIOLATION_NO":"8006327","VIOLATION_ISSUE_DT":"12/06/2012","SIG_SUB":"Y","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/19/2013","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2012-12-06"},{"SOURCE_ROW_NUMBER":"1951772","VIOLATION_NO":"8006326","VIOLATION_ISSUE_DT":"11/02/2012","SIG_SUB":"Y","PART_SECTION":"75.310(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2012","PROPOSED_PENALTY":"1111","AMOUNT_DUE":"1111","AMOUNT_PAID":"1111","CONTESTED_IND":"N","sourceDate":"2012-11-02"},{"SOURCE_ROW_NUMBER":"1951578","VIOLATION_NO":"7040712","VIOLATION_ISSUE_DT":"09/10/2012","SIG_SUB":"N","PART_SECTION":"75.1504(d)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/11/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"1951577","VIOLATION_NO":"7040711","VIOLATION_ISSUE_DT":"09/05/2012","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/05/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1951579","VIOLATION_NO":"8006372","VIOLATION_ISSUE_DT":"09/04/2012","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/04/2012","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2012-09-04"},{"SOURCE_ROW_NUMBER":"1951576","VIOLATION_NO":"7040710","VIOLATION_ISSUE_DT":"08/28/2012","SIG_SUB":"N","PART_SECTION":"75.1107-16(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-28"},{"SOURCE_ROW_NUMBER":"1951575","VIOLATION_NO":"7040705","VIOLATION_ISSUE_DT":"07/27/2012","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/27/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-27"},{"SOURCE_ROW_NUMBER":"1951587","VIOLATION_NO":"8006429","VIOLATION_ISSUE_DT":"07/26/2012","SIG_SUB":"Y","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/26/2012","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"243","CONTESTED_IND":"N","sourceDate":"2012-07-26"}]}],"safety":{"href":"/api/v1/mines/3608704/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608704/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Disconnecting devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.808","part":"75","subchapter":"O","subpart":"I","id":"75.808","citation":"30 CFR 75.808","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Mine emergency evacuation training and drills.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1504","part":"75","subchapter":"O","subpart":"P","id":"75.1504","citation":"30 CFR 75.1504","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608704","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}