{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3608694","name":"T.J.S. No. 4","status":"Abandoned and Sealed","status_date":"2004-08-11","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Armstrong","nearest_town":"Elderton","operator_id":"P21491","operator_name":"T.J.S. Mining, Inc.","controller_id":"C13674","controller_name":"Thomas J  Smith","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":40.697222,"longitude":-79.303055},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":841},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608694","name":"T.J.S. No. 4"},"operator":{"type":"operator","id":"P21491","name":"T.J.S. Mining, Inc."},"controller":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"object":{"type":"mine","id":"3608694","name":"T.J.S. No. 4"},"validFrom":"1991-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608694|C13674|1991-05-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21491","name":"T.J.S. Mining, Inc."},"object":{"type":"mine","id":"3608694","name":"T.J.S. No. 4"},"validFrom":"1997-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608694|P21491|1997-08-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13674","name":"Thomas J  Smith"},"object":{"type":"operator","id":"P21491","name":"T.J.S. Mining, Inc."},"validFrom":"1997-08-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608694","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608694|P21491|1997-08-01|C13674|1991-05-01|90788"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":32,"firstDate":"2000-01-25","lastDate":"2003-10-21","metrics":{"daysLost":947,"injuries":31,"fatalities":0,"recentRows":0,"restrictedDays":382,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"15688","DOCUMENT_NO":"220033070029","ACCIDENT_DT":"10/21/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"EE WAS ROOF BOLTING WHEN A PIECE OF ROCK MEASURING 1\"X 1'X 1'DISLODGED FROM ROOF STRIKING EE ON HIS RT.KNEE. EE CONTINUED WORKING UNTIL 10/24/03 AT WHICH TIME EE STARTED MISSING WORK.","sourceDate":"2003-10-21"},{"SOURCE_ROW_NUMBER":"97211","DOCUMENT_NO":"220032270043","ACCIDENT_DT":"07/24/2003","DEGREE_INJURY":"NO VALUE FOUND","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"WHILE PERFORMING HIS NORMAL DUTIES AS A ROOF BOLTER/MBC OPERATOR IN LOW COAL, EMPLOYEE EXPERIENCED PAIN/SWELLING IN BOTH KNEES. HE CONTINUED WORKING UNTIL 8/8/03 AT WHICH TIME HE STARTED MISSI NG WORK. DIAGNOSIS: PREPATELLAR BURSITIS.","sourceDate":"2003-07-24"},{"SOURCE_ROW_NUMBER":"7067","DOCUMENT_NO":"220032410039","ACCIDENT_DT":"07/24/2003","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","NARRATIVE":"EE WAS OPERATING A PERSONNEL CARRIER WHEN THE LEFT REAR WHEEL STRUCK A ROCK CAUSING HIS LOWER BACK TO BE JARRED. EE DID NOT MISS ANY WORK HOWEVER ON 8/21/03 HE STARTED RECEIVING THERAPY THUS M AKING THIS REPORT NOW A MEDICAL. WAS ALSO PLACED ON RESTRICTED DUTY.","sourceDate":"2003-07-24"},{"SOURCE_ROW_NUMBER":"179166","DOCUMENT_NO":"220032130054","ACCIDENT_DT":"07/21/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"EMPLOYEE WAS PUTTING BOLTER SUPPIES ONTO THE BOLTER WHEN HE EXPERIENCED PAIN IN LOWER BACK.","sourceDate":"2003-07-21"},{"SOURCE_ROW_NUMBER":"45767","DOCUMENT_NO":"220031950050","ACCIDENT_DT":"07/07/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"121","NARRATIVE":"WHIILE PERFORMING HIS NORMAL DUTIES AS A ROOF BOLTER/MBC OPERATOR IN LOW COAL - EE EXPERIENCED PAIN IN RIGHT KNEE. REPORTED 7/7/03.","sourceDate":"2003-07-07"},{"SOURCE_ROW_NUMBER":"24324","DOCUMENT_NO":"220031760025","ACCIDENT_DT":"06/11/2003","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Rubbed or abraded","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"37","NARRATIVE":"WHILE EMPLOYEE WAS PERFORMING HIS NORMAL DUTIES AS A CONTINUOUS MINER OPERATOR IN LOW COAL, EMPLOYEE EXPERIENCED PAIN IN LEFT KNEE AREA. EMPLOYEE CONTINUED WORKING UNTIL 6/11/03 AT WHICH TIME HE STARTED MISSING WORK FROM THIS OCCUPATIONAL ILLNESS.","sourceDate":"2003-06-11"},{"SOURCE_ROW_NUMBER":"97213","DOCUMENT_NO":"220030830149","ACCIDENT_DT":"03/15/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"88","NARRATIVE":"EMPLOYEE WAS RIDING PERSONNEL CARRIER ALONG WITH FELLOW CREW MEMBERS. THE OPERATOR HAD JUST COMPLETED TESTING THE BRAKES AND WAS STARTING DOWN INTO THE PIT WHEN THE REAR END OF THE PERSONNEL CARRIER WENT OUT THUS LOSING BRAKING CAPABILITY.EE ALONG WITH CO-WORKERS JUMPED OFF WITH EE LANDING ON WRIST.","sourceDate":"2003-03-15"},{"SOURCE_ROW_NUMBER":"256572","DOCUMENT_NO":"220030840057","ACCIDENT_DT":"03/10/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"EMPLOYEE WAS ASSISTING MECHANIC, MECHANIC WAS STRIKING WRENCH WITH SLEDGE HAMMER IN AN ATTEMPT TO LOOSEN BOLTS WHEN THE SLEDGE HAMMER GLANCED OFF WRENCH STRIKING THE EE ABOVE LEFT EYE.","sourceDate":"2003-03-10"},{"SOURCE_ROW_NUMBER":"135986","DOCUMENT_NO":"220030210115","ACCIDENT_DT":"01/06/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"NO VALUE FOUND","ACCIDENT_TYPE":"No Value Found","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"374","NARRATIVE":"WHILE PERFORMING HIS NORMAL DUTIES AS A MECHANIC EE EXPERIENCED PAIN IN LEFT KNEE.","sourceDate":"2003-01-06"},{"SOURCE_ROW_NUMBER":"11412","DOCUMENT_NO":"220023190010","ACCIDENT_DT":"11/05/2002","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Rubbed or abraded","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"WHILE PERFORMING HIS NORMAL DUTIES AS A SCOOP OPERATOR IN LOW CAOL-EE EXPERIENCED PAIN/SWELLING IN LEFT KNEE AREA.","sourceDate":"2002-11-05"},{"SOURCE_ROW_NUMBER":"97210","DOCUMENT_NO":"220023050069","ACCIDENT_DT":"10/21/2002","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","NARRATIVE":"WHILE EMPLOYEE WAS LOADING ROCK DUSTER WHEN A PIECE OF ROCK DISLODGED FROM ROOF LACERATING SMALL FINGER ON RIGHT HAND. EE RECEIVED SUTURES AND WAS PLACED ON RESTRICTIVE DUTY THUS MAKING THIS REPORT A MEDICAL.","sourceDate":"2002-10-21"},{"SOURCE_ROW_NUMBER":"243696","DOCUMENT_NO":"220022060018","ACCIDENT_DT":"07/03/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","NARRATIVE":"EE WAS CLEANING TRAVELWAY WITH SCOOP WHEN HE INADVERTENTLY RAN OVER A PIECE OF ROCK THAT WAS LAYING ONT HE TRAVELWAY THUS CAUSING THE EE TO STRIKE HIS HEAD AGAINST THE ROOF LINE. JAMMING NECK. EE STARTING RECEIVING PHYSICAL THERAPY ON","sourceDate":"2002-07-03"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-08-11","lastDate":"2004-08-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":89,"firstDate":"2000-01-04","lastDate":"2004-01-27","metrics":{"ss":35,"delinquent":86,"recentRows":0,"paidPenalty":7594,"proposedPenalty":7654,"currentAssessment":7654},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"666035","VIOLATION_NO":"7062099","ISSUE_DT":"01/27/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"666034","VIOLATION_NO":"7062098","ISSUE_DT":"01/27/2004","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"666033","VIOLATION_NO":"7062097","ISSUE_DT":"01/27/2004","CFR_STANDARD_CD":"75.1100-2(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"682045","VIOLATION_NO":"7052108","ISSUE_DT":"11/19/2003","CFR_STANDARD_CD":"75.321(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"75.00","CURRENT_ASSESSMENT_AMT":"75.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-11-19"},{"SOURCE_ROW_NUMBER":"682044","VIOLATION_NO":"7052107","ISSUE_DT":"11/19/2003","CFR_STANDARD_CD":"75.1202","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-11-19"},{"SOURCE_ROW_NUMBER":"682043","VIOLATION_NO":"7052104","ISSUE_DT":"11/05/2003","CFR_STANDARD_CD":"75.388(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-11-05"},{"SOURCE_ROW_NUMBER":"664788","VIOLATION_NO":"7060987","ISSUE_DT":"08/19/2003","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-08-19"},{"SOURCE_ROW_NUMBER":"664787","VIOLATION_NO":"7060986","ISSUE_DT":"08/19/2003","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-08-19"},{"SOURCE_ROW_NUMBER":"664786","VIOLATION_NO":"7060985","ISSUE_DT":"08/19/2003","CFR_STANDARD_CD":"75.520","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-08-19"},{"SOURCE_ROW_NUMBER":"665469","VIOLATION_NO":"7061706","ISSUE_DT":"04/28/2003","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-28"},{"SOURCE_ROW_NUMBER":"665468","VIOLATION_NO":"7061704","ISSUE_DT":"04/11/2003","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-11"},{"SOURCE_ROW_NUMBER":"665467","VIOLATION_NO":"7061703","ISSUE_DT":"04/10/2003","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"83.00","CURRENT_ASSESSMENT_AMT":"83.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-04-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":368,"firstDate":"2000-01-07","lastDate":"2004-02-04","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":9,"validSamples":359,"maxConcentration":4.503,"concentrationTotal":330.31},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1602234","CASS_NUM":"57505744","SMP_TAKEN_DT":"2/4/2004","CONC":".963","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"1203946","CASS_NUM":"57505713","SMP_TAKEN_DT":"2/4/2004","CONC":".564","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"993934","CASS_NUM":"57505641","SMP_TAKEN_DT":"2/4/2004","CONC":"1.537","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"967902","CASS_NUM":"57505684","SMP_TAKEN_DT":"2/4/2004","CONC":".94","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"882938","CASS_NUM":"57505747","SMP_TAKEN_DT":"2/4/2004","CONC":".924","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"459795","CASS_NUM":"57505738","SMP_TAKEN_DT":"2/4/2004","CONC":".147","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"325193","CASS_NUM":"57505741","SMP_TAKEN_DT":"2/4/2004","CONC":".129","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"28596","CASS_NUM":"50654473","SMP_TAKEN_DT":"1/10/2004","CONC":"2.088","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-10"},{"SOURCE_ROW_NUMBER":"782981","CASS_NUM":"50711584","SMP_TAKEN_DT":"1/9/2004","CONC":"2.731","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-09"},{"SOURCE_ROW_NUMBER":"62801","CASS_NUM":"50711662","SMP_TAKEN_DT":"1/8/2004","CONC":"2.923","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-08"},{"SOURCE_ROW_NUMBER":"1111507","CASS_NUM":"50711658","SMP_TAKEN_DT":"1/7/2004","CONC":".922","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-07"},{"SOURCE_ROW_NUMBER":"1459732","CASS_NUM":"50711591","SMP_TAKEN_DT":"1/6/2004","CONC":"1.086","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-01-06"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1997-08-01","lastDate":"1997-08-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":112,"firstDate":"2000-01-03","lastDate":"2004-08-03","metrics":{"inspectors":122,"recentRows":0,"onSiteHours":1412,"inspectionHours":2272.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"966434","EVENT_NO":"4020332","INSPECTION_BEGIN_DT":"08/03/2004","INSPECTION_END_DT":"08/03/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-08-03"},{"SOURCE_ROW_NUMBER":"96440","EVENT_NO":"4017497","INSPECTION_BEGIN_DT":"08/03/2004","INSPECTION_END_DT":"08/11/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2004-08-03"},{"SOURCE_ROW_NUMBER":"30781","EVENT_NO":"4019786","INSPECTION_BEGIN_DT":"05/18/2004","INSPECTION_END_DT":"05/18/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"629810","EVENT_NO":"4019777","INSPECTION_BEGIN_DT":"03/03/2004","INSPECTION_END_DT":"03/03/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2004-03-03"},{"SOURCE_ROW_NUMBER":"907390","EVENT_NO":"4019769","INSPECTION_BEGIN_DT":"02/03/2004","INSPECTION_END_DT":"02/11/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16.75","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2004-02-03"},{"SOURCE_ROW_NUMBER":"977382","EVENT_NO":"4019396","INSPECTION_BEGIN_DT":"01/15/2004","INSPECTION_END_DT":"01/21/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"104528","EVENT_NO":"4028496","INSPECTION_BEGIN_DT":"01/06/2004","INSPECTION_END_DT":"01/07/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2004-01-06"},{"SOURCE_ROW_NUMBER":"670593","EVENT_NO":"4019762","INSPECTION_BEGIN_DT":"01/02/2004","INSPECTION_END_DT":"02/11/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"55.25","SUM_TOTAL_ON_SITE_HOURS":"33.25","sourceDate":"2004-01-02"},{"SOURCE_ROW_NUMBER":"1156772","EVENT_NO":"4032299","INSPECTION_BEGIN_DT":"12/08/2003","INSPECTION_END_DT":"12/08/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2003-12-08"},{"SOURCE_ROW_NUMBER":"379278","EVENT_NO":"4032298","INSPECTION_BEGIN_DT":"12/04/2003","INSPECTION_END_DT":"12/05/2003","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2003-12-04"},{"SOURCE_ROW_NUMBER":"81808","EVENT_NO":"4032297","INSPECTION_BEGIN_DT":"12/04/2003","INSPECTION_END_DT":"12/05/2003","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2003-12-04"},{"SOURCE_ROW_NUMBER":"657683","EVENT_NO":"4032293","INSPECTION_BEGIN_DT":"11/05/2003","INSPECTION_END_DT":"11/05/2003","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2003-11-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":38,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q3":{"hours":0,"employees":0,"production":0},"2004-Q2":{"hours":0,"employees":0,"production":0},"2004-Q1":{"hours":5003,"employees":9,"production":14390},"2003-Q4":{"hours":6926,"employees":11,"production":22136},"2003-Q3":{"hours":7405,"employees":14,"production":18861},"2003-Q2":{"hours":8311,"employees":22,"production":26044},"2003-Q1":{"hours":12606,"employees":22,"production":44586},"2002-Q4":{"hours":12012,"employees":22,"production":41048},"2002-Q3":{"hours":12241,"employees":22,"production":44160},"2002-Q2":{"hours":13147,"employees":22,"production":48951},"2002-Q1":{"hours":13051,"employees":22,"production":49818},"2001-Q4":{"hours":12155,"employees":22,"production":43477}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":65640,"employees":32,"production":257230},"2001":{"hours":65209,"employees":29,"production":227643},"2002":{"hours":50451,"employees":22,"production":183977},"2003":{"hours":35248,"employees":18,"production":111627},"2004":{"hours":5003,"employees":9,"production":14390}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":45,"firstDate":"2000-03-23","lastDate":"2003-12-04","metrics":{"recentRows":0,"doseOver100":9,"actDoseTotal":3000,"pelDoseTotal":2385},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"162280","EVENT_NO":"4032298","SURVEY_DATE":"12/04/2003","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"19","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2003-12-04"},{"SOURCE_ROW_NUMBER":"162279","EVENT_NO":"4018776","SURVEY_DATE":"11/13/2002","OCCUPATION_CD_DESC":"FORKLIFT OPERATOR","MACHINE_CD":"17","MANUFACTURER_CD":"018","ACT_DOSE_85":"10","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2002-11-13"},{"SOURCE_ROW_NUMBER":"162278","EVENT_NO":"4018776","SURVEY_DATE":"11/13/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"12","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2002-11-13"},{"SOURCE_ROW_NUMBER":"162277","EVENT_NO":"4018773","SURVEY_DATE":"10/22/2002","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"056","ACT_DOSE_85":"145","PEL_DOSE_90":"128","SURVEY_TYPE":"I","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"162276","EVENT_NO":"4018773","SURVEY_DATE":"10/22/2002","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"056","ACT_DOSE_85":"114","PEL_DOSE_90":"113","SURVEY_TYPE":"I","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"162275","EVENT_NO":"4018773","SURVEY_DATE":"10/22/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"46","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"162274","EVENT_NO":"4018773","SURVEY_DATE":"10/22/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"37","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"162273","EVENT_NO":"4018773","SURVEY_DATE":"10/22/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"056","ACT_DOSE_85":"142","PEL_DOSE_90":"126","SURVEY_TYPE":"F","sourceDate":"2002-10-22"},{"SOURCE_ROW_NUMBER":"162262","EVENT_NO":"4017976","SURVEY_DATE":"04/29/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"24","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2002-04-29"},{"SOURCE_ROW_NUMBER":"162272","EVENT_NO":"4018737","SURVEY_DATE":"03/25/2002","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"44","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2002-03-25"},{"SOURCE_ROW_NUMBER":"162271","EVENT_NO":"4018737","SURVEY_DATE":"03/25/2002","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"056","ACT_DOSE_85":"85","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2002-03-25"},{"SOURCE_ROW_NUMBER":"162270","EVENT_NO":"4018737","SURVEY_DATE":"03/25/2002","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"056","ACT_DOSE_85":"118","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2002-03-25"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":53,"firstDate":"2000-02-03","lastDate":"2004-02-04","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":6.1,"validSamples":52,"quartzPctTotal":213.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"66284","CASSETTE_NO":"57505684","SAMPLE_DT":"02/04/2004","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"10896","CASSETTE_NO":"57505641","SAMPLE_DT":"02/04/2004","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"QUARTZ LABORATORY VOID","sourceDate":"2004-02-04"},{"SOURCE_ROW_NUMBER":"114615","CASSETTE_NO":"50711614","SAMPLE_DT":"01/15/2004","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-01-15"},{"SOURCE_ROW_NUMBER":"98750","CASSETTE_NO":"50711592","SAMPLE_DT":"12/30/2003","QUARTZ_PCT":"01.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-30"},{"SOURCE_ROW_NUMBER":"158718","CASSETTE_NO":"57505559","SAMPLE_DT":"12/08/2003","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-08"},{"SOURCE_ROW_NUMBER":"146797","CASSETTE_NO":"57505562","SAMPLE_DT":"12/08/2003","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-08"},{"SOURCE_ROW_NUMBER":"109491","CASSETTE_NO":"57505625","SAMPLE_DT":"12/08/2003","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-12-08"},{"SOURCE_ROW_NUMBER":"117102","CASSETTE_NO":"57505857","SAMPLE_DT":"11/05/2003","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-11-05"},{"SOURCE_ROW_NUMBER":"81083","CASSETTE_NO":"57505855","SAMPLE_DT":"11/05/2003","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-11-05"},{"SOURCE_ROW_NUMBER":"125177","CASSETTE_NO":"57505379","SAMPLE_DT":"08/26/2003","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-26"},{"SOURCE_ROW_NUMBER":"82822","CASSETTE_NO":"57505405","SAMPLE_DT":"08/26/2003","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-26"},{"SOURCE_ROW_NUMBER":"47520","CASSETTE_NO":"57505395","SAMPLE_DT":"08/26/2003","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-08-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":91,"firstDate":"2000-01-04","lastDate":"2004-01-27","metrics":{"ss":35,"amountDue":7654,"contested":0,"amountPaid":7594,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":7654},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1950396","VIOLATION_NO":"7062099","VIOLATION_ISSUE_DT":"01/27/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/27/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"1950395","VIOLATION_NO":"7062098","VIOLATION_ISSUE_DT":"01/27/2004","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/27/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"1950394","VIOLATION_NO":"7062097","VIOLATION_ISSUE_DT":"01/27/2004","SIG_SUB":"N","PART_SECTION":"75.1100-2(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/27/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-01-27"},{"SOURCE_ROW_NUMBER":"1950478","VIOLATION_NO":"7052108","VIOLATION_ISSUE_DT":"11/19/2003","SIG_SUB":"Y","PART_SECTION":"75.321(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/20/2003","PROPOSED_PENALTY":"75","AMOUNT_DUE":"75","AMOUNT_PAID":"75","CONTESTED_IND":"N","sourceDate":"2003-11-19"},{"SOURCE_ROW_NUMBER":"1950477","VIOLATION_NO":"7052107","VIOLATION_ISSUE_DT":"11/19/2003","SIG_SUB":"N","PART_SECTION":"75.1202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/19/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-11-19"},{"SOURCE_ROW_NUMBER":"1950476","VIOLATION_NO":"7052104","VIOLATION_ISSUE_DT":"11/05/2003","SIG_SUB":"Y","PART_SECTION":"75.388(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/05/2003","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2003-11-05"},{"SOURCE_ROW_NUMBER":"1950441","VIOLATION_NO":"7060988","VIOLATION_ISSUE_DT":"08/20/2003","PART_SECTION":"75.1403-5(g)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"08/26/2003","CONTESTED_IND":"N","sourceDate":"2003-08-20"},{"SOURCE_ROW_NUMBER":"1950440","VIOLATION_NO":"7060987","VIOLATION_ISSUE_DT":"08/19/2003","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/19/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-08-19"},{"SOURCE_ROW_NUMBER":"1950439","VIOLATION_NO":"7060986","VIOLATION_ISSUE_DT":"08/19/2003","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/19/2003","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2003-08-19"},{"SOURCE_ROW_NUMBER":"1950438","VIOLATION_NO":"7060985","VIOLATION_ISSUE_DT":"08/19/2003","SIG_SUB":"N","PART_SECTION":"75.520","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-08-19"},{"SOURCE_ROW_NUMBER":"1950428","VIOLATION_NO":"7061706","VIOLATION_ISSUE_DT":"04/28/2003","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/28/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-04-28"},{"SOURCE_ROW_NUMBER":"1950427","VIOLATION_NO":"7061704","VIOLATION_ISSUE_DT":"04/11/2003","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/11/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-04-11"}]}],"safety":{"href":"/api/v1/mines/3608694/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608694/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.321","heading":"Air quality.","id":"75.321","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.321","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The air in areas where persons work or travel, except as specified in paragraph (a)(2) of this section, shall contain at least 19.5 percent oxygen and not more than 0.5 percent carbon dioxide, and the volume and velocity of the air current in these areas shall be sufficient to dilute, render harmless, and carry away flammable, explosive, noxious, and harmful gases, dusts, smoke, and fumes.\n\n(2) The air in areas of bleeder entries and worked-out areas where persons work or travel shall contain at least 19.5 percent oxygen, and carbon dioxide levels shall not exceed 0.5 percent time weighted average and 3.0 percent short term exposure limit.\n\n(b) Notwithstanding the provisions of § 75.322, for the purpose of preventing explosions from gases other than methane, the following gases shall not be permitted to accumulate in excess of the concentrations listed below:\n\n(1) Carbon monoxide (CO)—2.5 percent\n\n(2) Hydrogen (H2)—.80 percent\n\n(3) Hydrogen sulfide (H2 S)—.80 percent\n\n(4) Acetylene (C2 H2)—.40 percent\n\n(5) Propane (C3 H8)—.40 percent\n\n(6) MAPP (methyl-acetylene-propylene-propodiene)—.30 percent","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1202","heading":"Temporary notations, revisions, and supplements.","id":"75.1202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"M","subpartHeading":"Subpart M—Maps","text":"[Statutory Provisions]\n\nSuch map shall be kept up-to-date by temporary notations and such map shall be revised and supplemented at intervals prescribed by the Secretary on the basis of a survey made or certified by such engineer or surveyor.","occurrenceCount":1},{"chapter":"I","heading":"Boreholes in advance of mining.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.388","part":"75","subchapter":"O","subpart":"D","id":"75.388","citation":"30 CFR 75.388","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-5","heading":"Criteria—Belt conveyors.","id":"75.1403-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Positive-acting stop controls should be installed along all belt conveyors used to transport men, and such controls should be readily accessible and maintained so that the belt can be stopped or started at any location.\n\n(b) Belt conveyors used for regularly scheduled mantrips should be stopped while men are loading or unloading.\n\n(c) All belt conveyors used for the transportation of persons should have a minimum vertical clearance of 18 inches from the nearest overhead projection when measured from the edge of the belt and there should be at least 36 inches of side clearance where men board or leave such belt conveyors.\n\n(d) When men are being transported on regularly scheduled mantrips on belt conveyors the belt speed should not exceed 300 feet per minute when the vertical clearance is less than 24 inches, and should not exceed 350 feet per minute when the vertical clearance is 24 inches or more.\n\n(e) Adequate illumination including colored lights or reflective signs should be installed at all loading and unloading stations. Such colored lights and reflective signs should be so located as to be observable to all persons riding the belt conveyor.\n\n(f) After supplies have been transported on belt conveyors such belts should be examined for unsafe conditions prior to the transportation of men on regularly scheduled mantrips, and belt conveyors should be clear before men are transported.\n\n(g) A clear travelway at least 24 inches wide should be provided on both sides of all belt conveyors installed after March 30, 1970. Where roof supports are installed within 24 inches of a belt conveyor, a clear travelway at least 24 inches wide should be provided on the side of such support farthest from the conveyor.\n\n(h) On belt conveyors that do not transport men, stop and start controls should be installed at intervals not to exceed 1,000 feet. Such controls should be properly installed and positioned so as to be readily accessible.\n\n(i) Telephone or other suitable communications should be provided at points where men or supplies are regularly loaded on or unloaded from the belt conveyors.\n\n(j) Persons should not cross moving belt conveyors, except where suitable crossing facilities are provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; switches.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.520","part":"75","subchapter":"O","subpart":"F","id":"75.520","citation":"30 CFR 75.520","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608694","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}