{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3608540","name":"Keystone Cleaning Plant","status":"Abandoned","status_date":"2017-07-19","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Armstrong","nearest_town":"Elderton","operator_id":"0148553","operator_name":"Murray Keystone Processing, Inc.","controller_id":"C13408","controller_name":"Robert E  Murray","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":40.649722,"longitude":-79.283056},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1256},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"operator":{"type":"operator","id":"0148553","name":"Murray Keystone Processing, Inc."},"controller":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01537","name":"Rochester & Pittsburgh Coal Company"},"object":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|C01537|1950-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P07915","name":"Keystone Coal Mining Corp"},"object":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"validFrom":"1996-01-01","validTo":"1998-09-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|P07915|1996-01-01|1998-09-21"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01537","name":"Rochester & Pittsburgh Coal Company"},"object":{"type":"operator","id":"P07915","name":"Keystone Coal Mining Corp"},"validFrom":"1996-01-01","validTo":"1998-09-21","current":false,"derived":true,"evidenceMineId":"3608540","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|P07915|1996-01-01|C01537|1950-01-01|54585"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24198","name":"Keystone Coal Mining Corporation"},"object":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"validFrom":"1998-09-22","validTo":"2016-12-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|P24198|1998-09-22|2016-12-11"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"validFrom":"1998-09-22","validTo":"2013-12-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|C00692|1998-09-22|2013-12-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"operator","id":"P24198","name":"Keystone Coal Mining Corporation"},"validFrom":"1998-09-22","validTo":"2013-12-04","current":false,"derived":true,"evidenceMineId":"3608540","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|P24198|1998-09-22|C00692|1998-09-22|49350"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"validFrom":"2013-12-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|C13408|2013-12-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"P24198","name":"Keystone Coal Mining Corporation"},"validFrom":"2013-12-05","validTo":"2016-12-11","current":false,"derived":true,"evidenceMineId":"3608540","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|P24198|1998-09-22|C13408|2013-12-05|89679"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0148553","name":"Murray Keystone Processing, Inc."},"object":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"validFrom":"2016-12-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|0148553|2016-12-12|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"mine","id":"3608540","name":"Keystone Cleaning Plant"},"validFrom":"2016-12-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|C13408|2016-12-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13408","name":"Robert E  Murray"},"object":{"type":"operator","id":"0148553","name":"Murray Keystone Processing, Inc."},"validFrom":"2016-12-12","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608540","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608540|0148553|2016-12-12|C13408|2016-12-12|89807"}}],"coverage":{"historyRecords":4,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":5,"firstDate":"2000-04-20","lastDate":"2012-08-14","metrics":{"daysLost":189,"injuries":5,"fatalities":0,"recentRows":0,"restrictedDays":6,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"118707","DOCUMENT_NO":"220122330046","ACCIDENT_DT":"08/14/2012","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping replace UHMW chute liner. Injured e/e was holding liner in place inside chute while other e/e was outside chute drilling holes for mounting hardware. As he drilled through the liner, the drill bit entered into employee's left wrist resulting in left wrist trapezium avulsion fracture and puncture wound.","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"15680","DOCUMENT_NO":"220111040030","ACCIDENT_DT":"04/13/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was in shop fabrication splash guards for deslime feed bock to sieve from used belting. He was kneeling on the floor trimming the edge of fit, with a utility knife. The knife slipped and cut his right knee. He was treated on site then transported to the hospital where he received 6 sutures. He returned to work on his next scheduled shift.","sourceDate":"2011-04-13"},{"SOURCE_ROW_NUMBER":"269424","DOCUMENT_NO":"220101030061","ACCIDENT_DT":"04/05/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"30","NARRATIVE":"Employee was co-worker were replacing hold down strips on a vibrating screen. A support tube was between the two, separating their view. Employee reached under the tube to reposition the hold-down strip and the co-worker struck his ring finger with a sledge hammer.","sourceDate":"2010-04-05"},{"SOURCE_ROW_NUMBER":"273697","DOCUMENT_NO":"220002590062","ACCIDENT_DT":"09/05/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to lower level, NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"37","NARRATIVE":"EE WAS WASHING DOWN THE SCREENHOUSE WHEN HE STEPPED INTO A TRAP DOOR OPENING WHICH WAS LEFT UNCOVERED. HE FELL IN TO HIS WAIST. HE SUFFERED A PUNCTURE WOUND TO HIS LEFT LOWER LEG FROM THE OPEN GRATING AND REQUIRED 9 STITCHES. HE ALSO RECEIVED A SCRAPE AND BRUISE ON HIS RIGHT SIDE WHICH REQUIRED NO MEDICAL ATTENTION.","sourceDate":"2000-09-05"},{"SOURCE_ROW_NUMBER":"54302","DOCUMENT_NO":"220001220070","ACCIDENT_DT":"04/20/2000","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DISORDERS (REPEATED TRAUMA)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"122","NARRATIVE":"EMPLOYEE HAS COMPLAINED OF NUMBNESS, ACHING, TINGLEY FEELING IN BOTH HANDS AND ALSO A LOSS OF STRENGTH IN BOTH HANDS. THIS ILLNESS HAS BEEN DIAGNOSED AS CARPAL TUNNEL SYNDROME. THIS IS A RES ULT OF REPETITIVE MOTION DURING NORMAL WORK ACTIVITY. THIS IS AN OCCUPATIONAL ILLNESS.","sourceDate":"2000-04-20"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-07-19","lastDate":"2017-07-19","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":85,"firstDate":"2001-02-01","lastDate":"2015-03-12","metrics":{"ss":28,"delinquent":85,"recentRows":0,"paidPenalty":16539,"proposedPenalty":16539,"currentAssessment":16539},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1658201","VIOLATION_NO":"7026888","ISSUE_DT":"03/12/2015","CFR_STANDARD_CD":"77.1713(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-03-12"},{"SOURCE_ROW_NUMBER":"1658200","VIOLATION_NO":"7026887","ISSUE_DT":"03/10/2015","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-03-10"},{"SOURCE_ROW_NUMBER":"1658199","VIOLATION_NO":"7026886","ISSUE_DT":"03/10/2015","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-03-10"},{"SOURCE_ROW_NUMBER":"1658169","VIOLATION_NO":"7041525","ISSUE_DT":"07/01/2014","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-07-01"},{"SOURCE_ROW_NUMBER":"1658168","VIOLATION_NO":"7041524","ISSUE_DT":"06/30/2014","CFR_STANDARD_CD":"77.202","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-06-30"},{"SOURCE_ROW_NUMBER":"1657971","VIOLATION_NO":"7026550","ISSUE_DT":"12/30/2013","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-12-30"},{"SOURCE_ROW_NUMBER":"1657550","VIOLATION_NO":"8009481","ISSUE_DT":"08/28/2013","CFR_STANDARD_CD":"71.501","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-28"},{"SOURCE_ROW_NUMBER":"1657549","VIOLATION_NO":"8009478","ISSUE_DT":"08/20/2013","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-20"},{"SOURCE_ROW_NUMBER":"1657548","VIOLATION_NO":"8009477","ISSUE_DT":"08/19/2013","CFR_STANDARD_CD":"77.205(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-19"},{"SOURCE_ROW_NUMBER":"1663398","VIOLATION_NO":"7041050","ISSUE_DT":"03/25/2013","CFR_STANDARD_CD":"47.41(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-25"},{"SOURCE_ROW_NUMBER":"1663397","VIOLATION_NO":"7041049","ISSUE_DT":"03/21/2013","CFR_STANDARD_CD":"77.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-21"},{"SOURCE_ROW_NUMBER":"1663370","VIOLATION_NO":"7041004","ISSUE_DT":"09/25/2012","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-25"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":226,"firstDate":"2000-02-16","lastDate":"2016-05-26","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":5,"validSamples":221,"maxConcentration":3.749,"concentrationTotal":113.843},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"984337","CASS_NUM":"58278935","SMP_TAKEN_DT":"5/26/2016","CONC":".037","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"PREPARATION PLANT FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-05-26"},{"SOURCE_ROW_NUMBER":"326097","CASS_NUM":"58247940","SMP_TAKEN_DT":"3/1/2016","CONC":".106","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-03-01"},{"SOURCE_ROW_NUMBER":"32535","CASS_NUM":"58247950","SMP_TAKEN_DT":"3/1/2016","CONC":".014","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SUPERINTENDENT","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2016-03-01"},{"SOURCE_ROW_NUMBER":"204061","CASS_NUM":"51322790","SMP_TAKEN_DT":"12/10/2015","CONC":".046","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-12-10"},{"SOURCE_ROW_NUMBER":"98336","CASS_NUM":"51322803","SMP_TAKEN_DT":"9/10/2015","CONC":".029","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-09-10"},{"SOURCE_ROW_NUMBER":"1319872","CASS_NUM":"58229089","SMP_TAKEN_DT":"9/9/2015","CONC":".133","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-09-09"},{"SOURCE_ROW_NUMBER":"1010276","CASS_NUM":"58229088","SMP_TAKEN_DT":"9/9/2015","CONC":".055","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-09-09"},{"SOURCE_ROW_NUMBER":"568264","CASS_NUM":"58228822","SMP_TAKEN_DT":"9/9/2015","CONC":".053","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-09-09"},{"SOURCE_ROW_NUMBER":"1177257","CASS_NUM":"51340452","SMP_TAKEN_DT":"6/1/2015","CONC":".027","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-06-01"},{"SOURCE_ROW_NUMBER":"1323748","CASS_NUM":"58199772","SMP_TAKEN_DT":"3/11/2015","CONC":"1.034","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"FINE COAL PLANT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"1312099","CASS_NUM":"58199774","SMP_TAKEN_DT":"3/11/2015","CONC":".395","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"PREPARATION PLANT FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"355466","CASS_NUM":"58199713","SMP_TAKEN_DT":"3/11/2015","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-11"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2001-08-08","lastDate":"2006-08-09","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":426,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":101,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1996-01-01","lastDate":"2016-12-12","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":61,"firstDate":"2000-08-22","lastDate":"2016-05-26","metrics":{"inspectors":69,"recentRows":0,"onSiteHours":1034.25,"inspectionHours":1512.25,"inspectionSamples":119},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"782340","EVENT_NO":"6231638","INSPECTION_BEGIN_DT":"05/26/2016","INSPECTION_END_DT":"06/08/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2016-05-26"},{"SOURCE_ROW_NUMBER":"1127690","EVENT_NO":"6231622","INSPECTION_BEGIN_DT":"01/25/2016","INSPECTION_END_DT":"03/31/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"58","SUM_TOTAL_ON_SITE_HOURS":"40.25","sourceDate":"2016-01-25"},{"SOURCE_ROW_NUMBER":"822484","EVENT_NO":"6243141","INSPECTION_BEGIN_DT":"08/31/2015","INSPECTION_END_DT":"09/10/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"35","SUM_TOTAL_ON_SITE_HOURS":"23","sourceDate":"2015-08-31"},{"SOURCE_ROW_NUMBER":"498191","EVENT_NO":"6231583","INSPECTION_BEGIN_DT":"03/10/2015","INSPECTION_END_DT":"03/31/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"41.5","SUM_TOTAL_ON_SITE_HOURS":"27.5","sourceDate":"2015-03-10"},{"SOURCE_ROW_NUMBER":"621767","EVENT_NO":"6231551","INSPECTION_BEGIN_DT":"06/30/2014","INSPECTION_END_DT":"07/28/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"54.5","SUM_TOTAL_ON_SITE_HOURS":"38.5","sourceDate":"2014-06-30"},{"SOURCE_ROW_NUMBER":"663858","EVENT_NO":"6231431","INSPECTION_BEGIN_DT":"12/24/2013","INSPECTION_END_DT":"01/07/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"49.25","SUM_TOTAL_ON_SITE_HOURS":"30","sourceDate":"2013-12-24"},{"SOURCE_ROW_NUMBER":"771059","EVENT_NO":"6231243","INSPECTION_BEGIN_DT":"08/15/2013","INSPECTION_END_DT":"09/30/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"61.75","SUM_TOTAL_ON_SITE_HOURS":"41.75","sourceDate":"2013-08-15"},{"SOURCE_ROW_NUMBER":"977122","EVENT_NO":"6242336","INSPECTION_BEGIN_DT":"03/20/2013","INSPECTION_END_DT":"03/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"41","SUM_TOTAL_ON_SITE_HOURS":"25.25","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"1092368","EVENT_NO":"6242319","INSPECTION_BEGIN_DT":"09/24/2012","INSPECTION_END_DT":"09/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"38.75","SUM_TOTAL_ON_SITE_HOURS":"25.5","sourceDate":"2012-09-24"},{"SOURCE_ROW_NUMBER":"864543","EVENT_NO":"4050674","INSPECTION_BEGIN_DT":"03/13/2012","INSPECTION_END_DT":"03/19/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"39.5","SUM_TOTAL_ON_SITE_HOURS":"28.5","sourceDate":"2012-03-13"},{"SOURCE_ROW_NUMBER":"805893","EVENT_NO":"6230847","INSPECTION_BEGIN_DT":"08/30/2011","INSPECTION_END_DT":"09/08/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"41.5","SUM_TOTAL_ON_SITE_HOURS":"30","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"157952","EVENT_NO":"6230814","INSPECTION_BEGIN_DT":"03/11/2011","INSPECTION_END_DT":"03/30/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"41","SUM_TOTAL_ON_SITE_HOURS":"30","sourceDate":"2011-03-11"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":140,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q3":{"hours":0,"employees":0,"production":0},"2017-Q2":{"hours":0,"employees":0,"production":0},"2017-Q1":{"hours":0,"employees":0,"production":0},"2016-Q4":{"hours":205,"employees":3,"production":0},"2016-Q3":{"hours":120,"employees":3,"production":0},"2016-Q2":{"hours":918,"employees":5,"production":0},"2016-Q1":{"hours":1650,"employees":4,"production":0},"2015-Q4":{"hours":5217,"employees":11,"production":0},"2015-Q3":{"hours":5635,"employees":11,"production":0},"2015-Q2":{"hours":5658,"employees":10,"production":0},"2015-Q1":{"hours":5073,"employees":9,"production":0},"2014-Q4":{"hours":3908,"employees":8,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":28,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":23099,"employees":12,"production":0},"2008":{"hours":21634,"employees":11,"production":0},"2009":{"hours":21732,"employees":11,"production":0},"2010":{"hours":21035,"employees":11,"production":0},"2011":{"hours":23472,"employees":12,"production":0},"2012":{"hours":24523,"employees":13,"production":0},"2013":{"hours":23626,"employees":12,"production":0},"2014":{"hours":16353,"employees":9,"production":0},"2015":{"hours":21583,"employees":10,"production":0},"2016":{"hours":2893,"employees":4,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":67,"firstDate":"2000-08-22","lastDate":"2016-03-01","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":2651,"pelDoseTotal":1782},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"159416","EVENT_NO":"6231622","SURVEY_DATE":"03/01/2016","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"7","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2016-03-01"},{"SOURCE_ROW_NUMBER":"159415","EVENT_NO":"6231622","SURVEY_DATE":"03/01/2016","OCCUPATION_CD_DESC":"SUPERINTENDENT","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2016-03-01"},{"SOURCE_ROW_NUMBER":"159414","EVENT_NO":"6231583","SURVEY_DATE":"03/11/2015","OCCUPATION_CD_DESC":"WATERBOY","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"63","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"159413","EVENT_NO":"6231583","SURVEY_DATE":"03/11/2015","OCCUPATION_CD_DESC":"FINE COAL PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"77","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"159412","EVENT_NO":"6231583","SURVEY_DATE":"03/11/2015","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"27","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"159411","EVENT_NO":"6231583","SURVEY_DATE":"03/11/2015","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"159410","EVENT_NO":"6231583","SURVEY_DATE":"03/11/2015","OCCUPATION_CD_DESC":"PREPARATION PLANT FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"65","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"159409","EVENT_NO":"6231431","SURVEY_DATE":"01/03/2014","OCCUPATION_CD_DESC":"MECHANIC","ACT_DOSE_85":"15","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2014-01-03"},{"SOURCE_ROW_NUMBER":"159408","EVENT_NO":"6231431","SURVEY_DATE":"01/03/2014","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"38","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2014-01-03"},{"SOURCE_ROW_NUMBER":"159407","EVENT_NO":"6231431","SURVEY_DATE":"01/03/2014","OCCUPATION_CD_DESC":"FINE COAL PLANT OPERATOR","ACT_DOSE_85":"21","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2014-01-03"},{"SOURCE_ROW_NUMBER":"159406","EVENT_NO":"6231431","SURVEY_DATE":"01/03/2014","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","ACT_DOSE_85":"21","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2014-01-03"},{"SOURCE_ROW_NUMBER":"159420","EVENT_NO":"6242336","SURVEY_DATE":"03/25/2013","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2013-03-25"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":20,"firstDate":"2001-06-26","lastDate":"2015-03-11","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":9.7,"validSamples":20,"quartzPctTotal":23.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"60369","CASSETTE_NO":"58199772","SAMPLE_DT":"03/11/2015","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-03-11"},{"SOURCE_ROW_NUMBER":"38403","CASSETTE_NO":"58139927","SAMPLE_DT":"01/03/2014","QUARTZ_PCT":"00.6","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-01-03"},{"SOURCE_ROW_NUMBER":"156223","CASSETTE_NO":"58015593","SAMPLE_DT":"03/25/2013","QUARTZ_PCT":"00.2","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-03-25"},{"SOURCE_ROW_NUMBER":"50161","CASSETTE_NO":"57909107","SAMPLE_DT":"08/31/2011","QUARTZ_PCT":"00.3","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-31"},{"SOURCE_ROW_NUMBER":"36603","CASSETTE_NO":"57876184","SAMPLE_DT":"03/15/2011","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-15"},{"SOURCE_ROW_NUMBER":"16457","CASSETTE_NO":"57778885","SAMPLE_DT":"03/04/2010","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-03-04"},{"SOURCE_ROW_NUMBER":"60094","CASSETTE_NO":"57694283","SAMPLE_DT":"11/06/2008","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-11-06"},{"SOURCE_ROW_NUMBER":"218","CASSETTE_NO":"57668969","SAMPLE_DT":"03/17/2008","QUARTZ_PCT":"00.9","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-17"},{"SOURCE_ROW_NUMBER":"42101","CASSETTE_NO":"57668792","SAMPLE_DT":"03/12/2008","QUARTZ_PCT":"00.4","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-12"},{"SOURCE_ROW_NUMBER":"72913","CASSETTE_NO":"57574559","SAMPLE_DT":"01/17/2007","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-01-17"},{"SOURCE_ROW_NUMBER":"6353","CASSETTE_NO":"57580019","SAMPLE_DT":"02/15/2006","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"MECHANIC","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-15"},{"SOURCE_ROW_NUMBER":"147018","CASSETTE_NO":"57560082","SAMPLE_DT":"06/08/2005","QUARTZ_PCT":"00.2","OCC_CODE_DESC":"FINE COAL PLANT OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-06-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":85,"firstDate":"2001-02-01","lastDate":"2015-03-12","metrics":{"ss":28,"amountDue":16539,"contested":0,"amountPaid":16539,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":16539},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1943051","VIOLATION_NO":"7026888","VIOLATION_ISSUE_DT":"03/12/2015","SIG_SUB":"N","PART_SECTION":"77.1713(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"03/12/2015","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2015-03-12"},{"SOURCE_ROW_NUMBER":"1943050","VIOLATION_NO":"7026887","VIOLATION_ISSUE_DT":"03/10/2015","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/10/2015","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2015-03-10"},{"SOURCE_ROW_NUMBER":"1943049","VIOLATION_NO":"7026886","VIOLATION_ISSUE_DT":"03/10/2015","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/10/2015","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2015-03-10"},{"SOURCE_ROW_NUMBER":"1943073","VIOLATION_NO":"7041525","VIOLATION_ISSUE_DT":"07/01/2014","SIG_SUB":"N","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/01/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-07-01"},{"SOURCE_ROW_NUMBER":"1943072","VIOLATION_NO":"7041524","VIOLATION_ISSUE_DT":"06/30/2014","SIG_SUB":"N","PART_SECTION":"77.202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/30/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-06-30"},{"SOURCE_ROW_NUMBER":"1943109","VIOLATION_NO":"7026550","VIOLATION_ISSUE_DT":"12/30/2013","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/30/2013","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2013-12-30"},{"SOURCE_ROW_NUMBER":"1943076","VIOLATION_NO":"8009481","VIOLATION_ISSUE_DT":"08/28/2013","SIG_SUB":"N","PART_SECTION":"71.501","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"7","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-28"},{"SOURCE_ROW_NUMBER":"1943075","VIOLATION_NO":"8009478","VIOLATION_ISSUE_DT":"08/20/2013","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-20"},{"SOURCE_ROW_NUMBER":"1943074","VIOLATION_NO":"8009477","VIOLATION_ISSUE_DT":"08/19/2013","SIG_SUB":"N","PART_SECTION":"77.205(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/19/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-19"},{"SOURCE_ROW_NUMBER":"1943059","VIOLATION_NO":"7041050","VIOLATION_ISSUE_DT":"03/25/2013","SIG_SUB":"N","PART_SECTION":"47.41(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/25/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-03-25"},{"SOURCE_ROW_NUMBER":"1943058","VIOLATION_NO":"7041049","VIOLATION_ISSUE_DT":"03/21/2013","SIG_SUB":"N","PART_SECTION":"77.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/21/2013","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2013-03-21"},{"SOURCE_ROW_NUMBER":"1943097","VIOLATION_NO":"7041004","VIOLATION_ISSUE_DT":"09/25/2012","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/25/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-25"}]}],"safety":{"href":"/api/v1/mines/3608540/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608540/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1713","heading":"Daily inspection of surface coal mine; certified person; reports of inspection.","id":"77.1713","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1713","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) At least once during each working shift, or more often if necessary for safety, each active working area and each active surface installation shall be examined by a certified person designated by the operator to conduct such examinations for hazardous conditions and any hazardous conditions noted during such examinations shall be reported to the operator and shall be corrected by the operator.\n\n(b) If any hazardous condition noted during an examination conducted in accordance with paragraph (a) of this section creates an imminent danger, the person conducting such examination shall notify the operator and the operator shall withdraw all persons from the area affected, except those persons referred to in section 104(d) of the Act, until the danger is abated.\n\n(c) After each examination conducted in accordance with the provisions of paragraph (a) of this section, each certified person who conducted all or any part of the examination required shall enter with ink or indelible pencil in a book approved by the Secretary the date and a report of the condition of the mine or any area of the mine which he has inspected together with a report of the nature and location of any hazardous condition found to be present at the mine. The book in which such entries are made shall be kept in an area at the mine designated by the operator to minimize the danger of destruction by fire or other hazard.\n\n(d) All examination reports recorded in accordance with the provisions of paragraph (c) of this section shall include a report of the action taken to abate hazardous conditions and shall be signed or countersigned each day by at least one of the following persons:\n\n(1) The surface mine foreman;\n\n(2) The assistant superintendent of the mine;\n\n(3) The superintendent of the mine;\n\n(4) The person designated by the operator as responsible for health and safety at the mine; or,\n\n(5) An equivalent mine official.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995; 63 FR 58613, Oct. 30, 1998]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":2},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Dust accumulations in surface installations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.202","part":"77","subchapter":"O","subpart":"C","id":"77.202","citation":"30 CFR 77.202","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","heading":"Sanitary toilet facilities; maintenance.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-F/section-71.501","part":"71","subchapter":"O","subpart":"F","id":"71.501","citation":"30 CFR 71.501","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 47.41","heading":"Requirement for container labels.","id":"47.41","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-47/subpart-E/section-47.41","part":"47","partHeading":"PART 47—HAZARD COMMUNICATION (HazCom)","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"E","subpartHeading":"Subpart E—Container Labels and Other Forms of Warning","text":"(a) The operator must ensure that each container of a hazardous chemical has a label. If a container is tagged or marked with the appropriate information, it is labeled.\n\n(1) The operator must replace a container label immediately if it is missing or if the hazard information on the label is unreadable.\n\n(2) The operator must not remove or deface existing labels on containers of hazardous chemicals.\n\n(b) For each hazardous chemical produced at the mine, the operator must prepare a container label and update this label with any significant, new information about the chemical's hazards within 3 months of becoming aware of this information.\n\n(c) For each hazardous chemical brought to the mine, the operator must replace an outdated label when a revised label is received from the chemical's manufacturer or supplier. The operator is not responsible for an inaccurate label obtained from the chemical's manufacturer or supplier.","occurrenceCount":1},{"chapter":"I","heading":"Electric wiring and equipment; installation and maintenance.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.516","part":"77","subchapter":"O","subpart":"F","id":"77.516","citation":"30 CFR 77.516","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608540","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}